首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Monolithic silica capillary columns were successfully prepared in a fused silica capillary of 530 microm inner diameter and evaluated in HPLC after octadecylsilylation (ODS). Their efficiency and permeability were compared with those of columns pakked with 5-microm and 3-microm ODS-silica particles. The monolithic silica columns having different domain sizes (combined size of through-pore and skeleton) showed 2.5-4.0-times higher permeability (K= 5.2-8.4 x 10(-14) m2) than capillary columns packed with 3-mm particles, while giving similar column efficiency. The monolithic silica capillary columns gave a plate height of about 11-13 microm, or 11 200-13 400 theoretical plates/150 mm column length, in 80% methanol at a linear mobile phase velocity of 1.0 mm/s. The monolithic column having a smaller domain size showed higher column efficiency and higher pressure drop, although the monolithic column with a larger domain size showed better overall column performance, or smaller separation impedance (E value). The larger-diameter (530 microm id) monolithic silica capillary column afforded a good peak shape in gradient elution of proteins at a flow rate of up to 100 microL/min and an injection volume of up to 10 microL.  相似文献   

2.
Reduction of through-pore size and skeleton size of a monolithic silica column was attempted to provide high separation efficiency in a short time. Monolithic silica columns were prepared to have various sizes of skeletons (approximately 1-2 microm) and through-pores (approximately 2-8 microm) in a fused-silica capillary (50-200 microm I.D.). The columns were evaluated in HPLC after derivatization to C18 phase. It was possible to prepare monolithic silica structures in capillaries of up to 200 microm I.D. from a mixture of tetramethoxysilane and methyltrimethoxysilane. As expected, a monolithic silica column with smaller domain size showed higher column efficiency and higher pressure drop. High external porosity (> 80%) and large through-pores resulted in high permeability (K = 8 x 10(-14) -1.3 x 10(-12) m2) that was 2-30 times higher than that of a column packed with 5-mirom silica particles. The monolithic silica columns prepared in capillaries produced a plate height of about 8-12 microm with an 80% aqueous acetonitrile mobile phase at a linear velocity of 1 mm/s. Separation impedance, E, was found to be as low as 100 under optimum conditions, a value about an order of magnitude lower than reported for conventional columns packed with 5-microm particles. Although a column with smaller domain size generally resulted in higher separation impedance and the lower total performance, the monolithic silica columns showed performance beyond the limit of conventional particle-packed columns under pressure-driven conditions.  相似文献   

3.
Monolithic capillary columns were prepared by copolymerization of styrene and divinylbenzene inside a 200 microm i.d. fused silica capillary using a mixture of tetrahydrofuran and decanol as porogen. Important chromatographic features of the synthesized columns were characterized and critically compared to the properties of columns packed with micropellicular, octadecylated poly(styrene-co-divinylbenzene) (PS-DVB-C18) particles. The permeability of a 60 mm long monolithic column was slightly higher than that of an equally dimensioned column packed with PS-DVB-C18 beads and was invariant up to at least 250 bar column inlet pressure, indicating the high-pressure stability of the monolithic columns. Interestingly, monolithic columns showed a 3.6 times better separation efficiency for oligonucleotides than granular columns. To study differences of the molecular diffusion processes between granular and monolithic columns, Van Deemter plots were measured. Due to the favorable pore structure of monolithic columns all kind of diffusional band broadening was reduced two to five times. Using inverse size-exclusion chromatography a total porosity of 70% was determined, which consisted of internodule porosity (20%) and internal porosity (50%). The observed fast mass transfer and the resulting high separation efficiency suggested that the surface of the monolithic stationary phase is rather rough and does not feature real pores accessible to macromolecular analytes such as polypeptides or oligonucleotides. The maximum analytical loading capacity of monolithic columns for oligonucleotides was found to be in the region of 500 fmol, which compared well to the loading capacity of the granular columns. Batch-to-batch reproducibility proved to be better with granular stationary phases compared to monolithic stationary phase, in which each column bed is the result of a unique column preparation process.  相似文献   

4.
Gao Y  Wang Y  Wang C  Gu X  Yan C 《色谱》2012,30(5):487-494
以N,N-二甲基-N-甲基丙烯酰胺基丙基-N,N-二甲基-N-丙烷磺酸内盐(SPP)为单体,季戊四醇三丙烯酸酯(PETA)为交联剂,偶氮二异丁腈(AIBN)为引发剂及两类不同的致孔剂(乙醇/乙二醇和甲醇/1,4-丁二醇)制备了两种新型亲水性整体柱。为了获得理想的柱效、电渗流速度和渗透性,对制备整体柱的各反应物配比进行了研究和优化。比较了两种整体柱在渗透性和分离样品方面的性能,结果表明,以乙醇/乙二醇为致孔剂制备的整体柱在柱效、分离度方面优于以甲醇/1,4-丁二醇为致孔剂制备的整体柱,但在渗透性方面不及后者。探讨了流动相中盐浓度对核苷类样品保留的影响,发现当甲酸铵浓度从10 mmol/L增加到70 mmol/L时,核苷样品的保留因子呈现先增加后减小的状态。将制备的整体柱用于毛细管液相色谱和加压电色谱分别分离胺类、酚类和核苷类样品,获得了理想的分离效果。在分离酚类和核苷类混合样品时,发现加压毛细管电色谱在分离度和分离速度上均优于毛细管液相色谱。  相似文献   

5.
Monolithic capillary columns (320 microm I.D.) were prepared for capillary liquid chromatography (CLC) by radical polymerization of butylmethacrylate (BMA) and ethylenedimethacrylate (EDMA) in the presence of a porogen solvent containing propan-1-ol, butane-1,4-diol and water. The influence of the contents of the porogen solvent and EDMA in the polymerization mixture on the monolith porosity and column efficiency was investigated. The composition of the polymerization mixture was optimized to attain a minimum HETP of the order of tens of microm for test compounds with various polarities. The separation performance and selectivity of the most efficient monolithic column prepared was characterized by van Deemter curves, peak asymmetry factors and Walters hydrophobicity and silanol indices. It was demonstrated that the 320-microm I.D. monolithic column exhibited CLC separation performance similar to that observed for 100- and 150-microm I.D. monolithic columns reported in the literature; moreover, the 320-microm I.D. column was easier to operate in CLC and exhibited a higher sample loadability.  相似文献   

6.
Butyl methacrylate monolithic columns in 320 microm i.d. fused silica capillaries for reversed-phase capillary liquid chromatography were prepared by radical polymerization initiated thermally with azobisisobutyronitrile (AIBN). Polymerization mixture contained butyl methacrylate (BMA) as the function monomer and ethylene dimethacrylate (EDMA) as the crosslinking agent with 1,4-butanediol and 1-propanol as a binary porogen solvent. Ratio of 1,4-butanediol to 1-propanol in the porogen solvent was optimized regarding the monolithic column efficiency and performance. Total porosity, column permeability, separation impedance, Walters hydrophobicity index, retention factors, peak asymmetry factors, height equivalents to a theoretical plate and peak resolutions were used for characterization of the prepared monolithic columns. The polymerization mixture consisting of 17.8% of BMA, 21.8% of EDMA, 18.0% of 1,4-butanediol, 42.0% of 1-propanol and 0.4% AIBN generated monolithic columns of the best performance having a sufficient permeability and the lowest separation impedance. It was also demonstrated that monolithic columns of this composition exhibited good preparation reproducibility and an excellent pressure resistance when applied in capillary liquid chromatography.  相似文献   

7.
Low capacity anion exchangers for IC have been prepared by modification of nonporous uniformed silica MICRA microbeads and by modification of the organic polymeric monolithic matrixes prepared in situ in quarz capillary. Due to the small particle size (1.5 microm) high-performance adsorbents were prepared allowing to obtain up to 190,000 tp/m. However, the column possesses a very high back-pressure and can be used in a short length up to 50 mm only to meet the requirements of conventional chromatographic equipment. An analysis of a test mixture of seven anions was completed within 3 min with a back column pressure of about 350 bar (HETP of about 5.5 microm, where HETP is the height equivalent to the theoretical plate). Monolithic capillary columns provide lower efficiency per column unit length than MICRA columns; however, they can be used at a longer length because of their low flow resistance. Monolithic column of ca. 40 cm length has workable pressure below 10 bar and allows separation of a five anions test mixture within less than 10 min. A better efficiency of monolithic column (HETP approximately 75 microm) can be achieved at reduced flow rates when the analysis time is not a critical parameter.  相似文献   

8.
Monolithic columns of 2.7 mm I.D. have been prepared and used in electrochromatography (EC) separation. Although capillary electrochromatography (CEC) has higher separation efficiency, it displays some shortcomings, such as limited sample loadability and restricted concentration detectability etc. In this paper, we investigate the feasibility of EC separation with millimeter diameter monolithic columns. By using a designed preparation method of monolithic column packed with about 150 microm quartz sand, the effect of Joule heating can be reduced, and the processes of frit making and column packing can be avoided. The concentration detectability of the EC is improved comparing with that of CEC. Moreover, the separation efficiency of 52,000 plates/m was achieved with a 70 mm length and 2.7 mm I.D. monolithic column.  相似文献   

9.
Open tubular CEC (OT-CEC) column with a very high separation efficiency was prepared for peptides separation. A pretreated silica-fused capillary was reacted with 3-(methacryloxy) propyltrimethoxysilane followed by vinylbenzyl chloride and divinylbenzene to produce first thin monolithic monolayer. The second copolymer layer was formed on thin monolithic monolayer of the capillary by reversible addition-fragmentation transfer polymerization of N-phenylacrylamide and styrene. The key parameters including buffer pH value and organic modifier were systematically evaluated to provide the optimal chromatographic condition. The resultant OT-CEC columns were validated by separating a synthetic mixture of peptides and cytochrome C tryptic digest in capillary electrochromatography. The number of theoretical plates as high as 2.4 million per column was achieved for synthetic mixture peptides. In addition, the fabricated OT-CEC column also resolved more than 18 high-efficiency digestion peptides from a mixture containing tryptic digest of cytochrome C. The column to column and inter- to intraday repeatabilities of OT-CEC column through RSD% were found better than 3.0%, exhibiting satisfactory stability and repeatability of the two-layer deposited OT-CEC column. The results reveal that the open tubular capillary column modified with two-layer copolymer shows the great prospect for the separation of proteins in capillary electrochromatography.  相似文献   

10.
反相毛细管整体柱的制备及其在多肽混合物分离中的应用   总被引:3,自引:3,他引:0  
谢晶鑫  毕开顺  钱小红  张养军 《色谱》2009,27(2):186-190
采用甲基丙烯酸月桂酯为基础功能单体,乙二醇二甲基丙烯酸酯为交联剂,正十二醇、1,4-丁二醇及二甲基亚砜为致孔剂,在内径为75 μm的石英毛细管内制备了具有良好机械性能及化学稳定性的反相毛细管整体柱。考察了致孔剂的种类、比例以及交联剂在单体混合物中的比例对柱压和分离效果的影响;以单体15%、交联剂15%、致孔剂70%(均为质量分数)作为优化配方,在70 ℃条件下反应24 h;并对所合成的毛细管整体柱进行了电镜表征,测试了流速、柱长与柱压的关系。结果表明,毛细管整体柱的通透性良好,可通过延长柱长的方法提高分离效果。将所制备的毛细管整体柱装于纳升级高效液相色谱仪上进行牛血清白蛋白及血浆样本的胰蛋白酶酶切液的分离,获得了比较理想的分离效果。  相似文献   

11.
Monolithic columns having long hydrocarbon chains were prepared by in-situ polymerization in capillary fused silica tubing. The capillary columns were coupled with a newly developed carbon fiber electrospray ionization (ESI) emitter for proteomic analysis using sheathless capillary HPLC-ESI mass spectrometry (MS). The sample loading capacity and chromatographic performance of the styrene-based monolithic column, which was prepared by photo-polymerization of octylstyrene (OS) and divinylbenzene (DVB) were compared with that of the methacrylate-based monolithic column composed of lauryl methacrylate (LMA) and ethylene dimethacrylate (EDMA). The sample loading ability of tryptic digested protein in poly-OS (POS)-DVB column was higher than that of poly-LMA (PLMA)-EDMA column, possibly due to the irregular and rugluous surface offering a greater surface area of POS-DVB stationary phase. The POS-DVB column also provided better separation efficiency in the separation of high concentration (10 microg) of tryptic digested albumin bovine serum (BSA). Due to the successful interface of a highly efficient monolithic column and a stable, durable carbon fiber emitter, low femtomole levels of peptides were successfully separated and identified in the presence of large amounts of tryptic digested protein.  相似文献   

12.
High efficiency and highly retentive monolithic silica capillary columns were obtained by polymerization of octadecyl methacrylate using alpha,alpha'-azobis-isobutyronitrile (AIBN) as a free radical initiator. Hybrid type monolithic silica columns (25 cm total length x 200 microm I.D.) prepared from a mixture of tetramethoxysilane and methyltrimethoxysilane were used as a support. The effects of the monomer and the radical initiator concentrations in the reaction mixture were examined. The performance of the columns was tested in terms of column efficiency and retention behavior by using alkylbenzenes and a few other compounds as solutes and compared with that of hybrid monolithic silica columns modified with octadecylsilyl-(N,N-diethylamino)silane (ODS-DEA). Highly retentive monolithic silica columns were obtained by polymerization at high monomer concentrations. Although a decrease in column efficiency was observed with the increase in the monomer concentration in a feed mixture, an improvement in efficiency was achieved (a plate height value lower than 10 microm) by increasing an initiator concentration without significant variations in column retention properties. Results obtained by polymerization using other monomers are also presented to demonstrate the applicability of the preparation method.  相似文献   

13.
Novel monolithic supports (MS/BVPE) were prepared by thermally initiated free radical copolymerisation of p-methylstyrene (MS) and 1,2-bis(p-vinylphenyl)ethane (BVPE). The polymer was synthesised in fused silica capillaries (80 mm x 0.2 mm and 80 mm x 0.53 mm) and in borosilicate glass columns (90 mm x 1.0 mm and 90 mm x 3.0 mm) to yield different HPLC column designs. A comparison of those column dimensions regarding morphology as well as separation efficiency and applicability in bioanalysis is presented. The efficiency towards proteins as well as oligonucleotides was found to be considerably improved with decreasing column I.D. While a 5-protein mixture was baseline separated on all investigated column designs, the separation of small biomolecules like oligonucleotides or peptides on microbore and conventional size glass columns was strongly restricted in terms of resolution due to extensive peak broadening or the occurrence of peak asymmetry. Monolithic MS/BVPE capillary columns up to 0.53 mm I.D., however, proved to be applicable to the fractionation of the whole spectrum of biopolymers, including proteins, peptides, oligonucleotides as well as double-stranded DNA fragments. Due to the fact that reliable chromatography makes great demand on the robustness of the stationary phase, monolithic MS/BVPE capillaries were subjected to a comprehensive reproducibility study including run-to-run as well as batch-to-batch reproducibility.  相似文献   

14.
A novel monolithic capillary column (530 microm i.d.) was prepared for capillary liquid chromatography (CLC) by in situ copolymerization of octyl methacrylate (MAOE) and ethylene dimethacrylate (EDMA) in the presence of a porogen solvent containing 1-propanol, 1,4-butanediol, and water with azobisisobutyronitrile as the initiator. The influences of the contents of the porogen solvent, EDMA and the various concentration ratios of 1-propanol to 1,4-butanediol in the polymerization mixture on the morphology, porosity, globule size, stability and column efficiency were investigated. The morphology and pore size distribution of monolithic capillary columns were characterized by SEM and mercury intrusion porosimetry, respectively. Chromatographic evaluations of the columns were performed under CLC mode. The results showed that good permeability and stability can be obtained under optimal experimental conditions. The separation results of some acid, neutral and basic analytes demonstrated the hydrophobicity and low affinity to basic analytes of the new column. Three metal ions, i.e. Mg(II), Zn(II) and Cd(II) were also separated under ion-pair mode on the new monolithic capillary column and the results were acceptable.  相似文献   

15.
Divinylbenzene polymer monolithic capillary columns were prepared on the basis of capillaries 0.01 to 0.53 mm in diameter. Separation properties of the columns were investigated with the use of a test mixture of light hydrocarbons. The permeability and C parameter in the Van Deemter equation were determined for all the columns. For the most part, the columns had similar characteristics: permeability was in the range (2.2 ± 0.2) × 10?9 cm2, with parameter C in the range (0.7 ± 0.2) × 10?3 s (with n-butane as a sorbate). It was thus established that capillary diameter has only a slight effect on the efficiency of monolithic capillary columns (unlike packed capillary columns and microcolumns, whose properties, according to the literature data, depend strongly on the column diameter). The difference in properties between the narrowest monolithic column (capillary diameter 0.01 mm) and the others is explained by column overloading.  相似文献   

16.
Chen Z  Ozawa H  Uchiyama K  Hobo T 《Electrophoresis》2003,24(15):2550-2558
We describe beta- and gamma-cyclodextrins (beta- and gamma-CD)-modified monolithic columns prepared by sol-gel process and chemical modifications. The monolithic silica column was fabricated inside a fused-silica capillary with 100 microm inner diameter by sol-gel process. The monolithic silica matrix was chemically modified chiral selectors of beta- or gamma-CDs with a spacer of 3-glycidoxypropyltrimethoxysilane by on-column reactions. Gamma-CD-modified monolithic column has successfully been applied for the separation of dansyl amino acid enantiomers. Beta-CD-modified monolithic column has been used for the separation of the positional isomers of o-, m-, and p-cresols and the enantioseparation of racemates of benzoin and several dansyl amino acids by capillary electrochromatography, respectively. For the separation of neutral positional isomers, a positive electric field was applied. However, for the separation of negatively charged analytes, a negative electric field was applied at the inlet of column. The separation efficiency of 5.0 x 10(4) theoretical plates/m for dansyl-L-threonine was obtained at electric field strength of -300 V/cm in the mobile phase of 50 mM 2-(N-morpholino)ethanesulfonic acid (MES)-Tris/methanol (70/30) buffer at pH 7.0. L-enantiomers were eluted as the first peak. Scanning electron micrograph showed that monolithic columns have the morphology of continuous skeleton and large through-pores.  相似文献   

17.
Monolithic capillary columns have been prepared in fused‐silica capillaries by radical co‐polymerization of ethylene dimethacrylate and butyl methacrylate in the presence of porogen solvent mixtures containing various concentration ratios of 1‐propanol, 1,4‐butanediol, and water with azobisisobutyronitrile as the initiator of the polymerization reaction. The through pores in organic polymer monolithic columns can be characterized by “equivalent permeability particle size”, and the mesopores with stagnant mobile phase by “equivalent dispersion particle size”. Increasing the concentration of propanol in the polymerization mixture diminishes the pore volume and size in the monolithic media and improves the column efficiency, at a cost of decreasing permeability. Organic polymer monolithic capillary columns show similar retention behaviour to packed alkyl silica columns for compounds with different polarities characterized by interaction indices, Ix, but have different methylene selectivities. Higher concentrations of propanol in the polymerization mixture increase the lipophilic character of the monolithic stationary phases. Best efficiencies and separation selectivities were found for monolithic columns prepared using 62–64% propanol in the porogen solvent mixture. To allow accurate characterization of the properties of capillary monolithic columns, the experimental data should be corrected for extra‐column contributions.  相似文献   

18.
The gain in separation efficiency for protein digests using long monolithic columns has been evaluated for a LC‐MS system with capillary monolithic columns of different lengths (150 and 750 mm). A mixture of BSA, α‐casein and β‐casein tryptic digests was used as a test sample. Peak capacity and productivity (peak capacity per unit time) were determined from base peak chromatograms and MS/MS data were used for protein identification by MASCOT database searching. Peak capacity and protein identification scores were higher for the long column. Analyses with similar gradient slope for the two columns produced ratios of the peak capacities that were slightly higher than the expected value of the square root of the column length ratio. Peak capacity ratios varied from 2.7 to 4.0 for four different gradient slopes, while protein identification scores were 2–4 times higher for the long column. Similar values were obtained for the productivity of both columns and the highest productivity was obtained at gradient times of 45 and 75 min for the short and long column, respectively. The use of long monolithic columns improves peptide separation and increases reliability of protein identification for complex digests, especially if longer gradients are chosen.  相似文献   

19.
Monolithic silica columns of 2.7 mm ID were prepared and derivatized with C8-TEOS and TEOS by on-column sol-gel reaction. These C8 large diameter monolithic silica columns gave 21 000 theoretical plates for aromatic hydrocarbons in 60% acetonitrile and 40% Tris-HCI buffer. The surface areas as well as the separation reproducibility were improved on coating by the sol-gel approach. Joule heating was greatly reduced by using monolithic columns to which fine quartz sand had been added during column preparation. Since this is a preliminary investigation on a monolithic column with such a large inner diameter, the separation efficiency was not so high as that presently achieved in normal capillary electrochromatography (CEC). However, use of the columns improved sample loadability and concentration detectability of electrochromatography, and semi-preparative separations could be performed.  相似文献   

20.
Monolithic capillary columns were prepared via electron beam triggered free radical polymerization within the confines of 0.2 and 0.1mm I.D. capillary columns using ethyl methacrylate and trimethylolpropane triacrylate as monomers as well as 2-propanol, 1-dodecanol and toluene as porogenic system. The influence of column diameter on reproducibility and separation performance was investigated. For evaluation, a protein standard consisting of five proteins in the range of 5800-66,000 g mol(-1) was used. Reproducibility was checked by determining the relative standard deviations in retention times, peak widths at half height, asymmetry and resolution. Excellent run-to-run reproducibility was found for both 0.2 and 0.1mm I.D. columns; batch-to-batch reproducibility was good for both column types. In order to enhance the non-polar character of the monolithic columns, lauryl methacrylate-based capillary columns were prepared. These were successfully used for the separation of proteins and a cytochrome c digest.  相似文献   