首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple and novel electrogenerated chemiluminescence (ECL) method for the determination of sulfite has been developed based on the energy transfer ECL process. It was found that a weak ECL signal of sulfite was electrochemically generated on a platinum electrode in neutral aqueous solution. The signal was strongly enhanced by rhodamine B as an energy receptor and further enhanced by the neutral surfactant Tween 80. In 0.10M phosphate buffer solution (pH=7.5) containing 2.0×10–6gmL–1 rhodamine B and 0.4% (v/v) Tween 80, the ECL response to the concentration of sulfite at a potential of 0.82V was linear over a range of 1.0×10–7gmL–1 to 8.0×10–6gmL–1, and the detection limit was 5×10–8gmL–1. The relative standard deviation (n=11, 1.0×10–6gmL–1) was 3.8%. The proposed method has been successfully applied to the determination of sulfite in pharmaceutical injections and white sugar samples.  相似文献   

2.
A single-wall carbon nanotubes (SWNT) film coated glassy carbon electrode (GCE) was fabricated for the direct determination of 4-nitrophenol (4-NP). The electrochemical behaviors of 4-NP at the SWNT-film coated GCE were examined. In 0.1M phosphate buffer with a pH of 5.0, 4-NP yields a very sensitive and well-defined reduction peak at the SWNT-modified GCE. It is found that the SWNT film exhibits obvious electrocatalytic activity towards the reduction of 4-NP since it not only increases the reduction peak current but also lowers the reduction overpotential. Based on this, an electrochemical method was proposed for the direct determination of 4-NP. The reduction peak current varies linearly with the concentration of 4-NP ranging from 1×10–8 to 5×10–6M, and the detection limit is 2.5×10–9M after 3min of open-circuit accumulation. The relative standard deviation at 2×10–7M 4-NP was about 6% (n=10), suggesting excellent reproducibility. This new method was successfully employed to determine 4-NP in several lake water samples.  相似文献   

3.
A -mercaptopropionic acid (MPA) self-assembled monolayer modified electrode (MPA/SAM/Au) on a gold electrode has been fabricated. The characterization of the MPA/SAM/Au was investigated using attenuated total reflection-fourier transform infrared (ATR-FTIR) and A.C. impedance. The electrochemical behaviors of p-aminophenol (p-AP) were studied at the MPA/SAM/Au by cyclic voltammetry and semi-derivative voltammetry (SDV) in BR buffer solution. The modified electrode shows excellent electrocatalytic activity for the redox of p-AP and accelerates the electron transfer rate. The diffusion coefficient (D) is 4.55×10–6cm2s–1. The oxidative peak current increases linearly with the concentration of p-AP in the range of 4.0×10–88×10–6molL–1 and 1.0×10–52×10–4molL–1 by square wave voltammetry response, respectively. The detection limit (three times the signal blank/slope) is up to 1.2×10–8molL–1. The modified electrode is able to eliminate the interference of p-benzenediol, o-benzenediol and o-AP at a 40-, 90- or 70-fold concentration of p-AP, and it has been satisfactorily used for the determination of the real sample.  相似文献   

4.
The fabrication and electrochemical characteristics of a penicillamine (PCA) self-assembled monolayer modified gold electrode were investigated. The self-assembled electrode shows obvious electrocatalytic activity for the oxidation of epinephrine (EP). In phosphate buffer (pH 7.73), a sensitive oxidation peak was observed at 0.190V with the PCA modified Au electrode. The peak current is proportional to the concentration of EP in the range of 2.0×10–56.0×10–4molL–1 and 5.0×10–6 2.0×10–4molL–1 for cyclic voltammetry (CV) and differential pulse voltammetry (DPV) with the detection limits of 1.8×10–7 and 1.3×10–7molL–1, respectively. The possible reaction mechanism is also discussed. The PCA self-assembled monolayer modified gold electrode is highly stable and can be applied to the determination of EP in practical injection samples. Application is simple, rapid and produces accurate results.  相似文献   

5.
The growth of Au on the stable, high-index Si(5512) surface has been studied using scanning tunneling microscopy (STM). At very low coverages and moderate annealing temperatures (0.1ML, 400–500°C), Au appears to decorate the underlying Si rows and form an array of rows that maintains the underlying (5512) periodicity of 5.4nm. For higher annealing temperatures and coverages, however, Au causes faceting to a number of nearby planes. The two primary facets formed at lower (0.15ML) and higher (0.5–2ML) coverages are the (337) and (225) planes, which are tilted 0.7° down [towards (111)] and 1.1° up from (5512), respectively. Both orientations are in fact subunits of the (5512) unit cell, so their presence is not surprising. In addition to these facets, two types of sawtooth morphologies composed of planes oriented further from (5512) are found at very high annealing temperatures (800–900°C). These include (113)+(7715) planes at very low coverage (0.05ml) and (113)+(5511) planes at higher coverage (1ML), where (113) is tilted up by 5.3° and (7715) and (5511) are tilted down by 2.9° and 2.2°, respectively. Au adsorption on Si(5512) therefore results in the formation of five possible facet planes: (113), (225), (337), (5511), and (7715).  相似文献   

6.
Cinnamtannin B1 (trimeric proanthocyanidin), which is identified and isolated from the effective fraction of the root of Lindera aggregata (Sims) Kosterm, is one kind of condensed tannin used as an effective antipyrotic and antitumor agent. Its electrochemical response can be obtained at a pyrolytic graphite electrode. Consequently, an easily performed and sensitive method for the determination of cinnamtannin B1 is developed. The detection limit is estimated to be 1.0×10–7M with the linear determination range of 2.0×10–7M to 1.8×10–6M. Five replicate analyses of 1.0×10–6M cinnamtannin B1 yields an RSD value of 2.1%. Since the working electrode does not need to be modified with any other species, it is very stable, repeatable and easily treated, and this method therefore potentially useful in real sample analysis.  相似文献   

7.
This study aims to investigate the distribution of Na, K, Rb and Cs in human brains (5 individuals, 12 brain parts, mean age: 75 years). Distribution of the trace metals between lipid fraction and brain tissue was investigated in solvent extraction experiments. Determinations were carried out by instrumental neutron activation analysis. The present results show a rather non-homogeneous distribution for Na and a relatively uniform distribution for K, Rb and Cs. The mean concentrations found are 7440µgNag–1 dry weight, 12800µgKg–1, 14µgRbg–1 and 50ngCsg–1. A highly significant positive correlation was found between Rb and Cs. Solvent extraction experiments showed that 19% of Rb and 26% of Cs of the total content is located in lipid fraction.  相似文献   

8.
A sub-micrometer thin-layer DNA modified carbon fiber microcylinder electrode was prepared by electrodeposition of ct-DNA at 1.5V (vs. Ag/AgCl). The voltammetric behavior of dopamine (3-hydroxytyramine) was investigated at the modified electrode. It was found that the modified electrode exhibits a highly electrocatalytic activity toward dopamine oxidation. Differential pulse voltammetry was used for determination of dopamine in pH 7.4 phosphate buffer solution. A linear response of the peak current versus the concentration was found in the range of 4×10–6 to 10–4molL–1 at 10–4molL–1 AA (ascorbic acid) coexistence (R=0.9959) and the range of 6×10–5 to 10–3molL–1 at 10–3molL–1 AA (R=0.9960). The presence of a high concentration of ascorbic acid did not interfere with the determination. The proposed method exhibited good recovery and reproducibility. This method can be applied to the detection of DA in real samples.  相似文献   

9.
The kinetics of formation and dissociation reactions of [Ru(CN)5L]3– with a series of heterocyclic ligands were studied in aqueous media. In this presence of an excess of heterocycle, the observed second order rate constants were calculated from the kobs versus [ligand] plot at =0.100m NaClO4. Activation parameters for the formation reactions (H=28±7kJmol–1 and S=140±35JK–1mol–1) are comparable for all systems, indicating a common mechanism. The kinetics of exchange of coordinated heterocycles for 1,3,5-triazine yielded a rate saturation typical of a limiting dissociative mechanism. Activation parameters of the limiting first order specific rate of dissociation reactions were H=85±7kJmol–1 and S=18±4JK–1mol–1. Equilibrium constants were calculated from the second order rates of formation and pseudo-first order rates of dissociation reaction.  相似文献   

10.
This study presents a PVC membrane based on 5,11,17,23,29,35-Hexakis-t-octyl-37,38,39,40,41,42-hexakis(N-phenylthiocarbamoylmethoxy)calix[6]arene which is used as an electroactive substance. The electrode reveals a Nernstian response for Ni2+ over a wide pH range with a slope of linear portion (5×10–6–1×10–2M, R=0.988) of 29.75±0.2mV·decade–1 at 25°C. The electrodes sensitivity is enhanced upon the introduction of sodium tetraphenylborate into the membrane as a negatively charged lipophilic additive. The selectivity coefficients of various interfering ions were determined using the fixed interference method (FIM). The membrane reveals good selectivity for nickel ions over the other metal ions investigated. The lifetime of this electrode is about one month. This electrode has been applied to the determination of nickel ions in wastewater from the electroplating industry.  相似文献   

11.
Summary. Steady state quenching studies of curcumin, 1,7-bis(4-hydroxy-3-methoxyphenyl)-1,6-heptadiene-3,5-dione, fluorescence by hydrogen peroxide were conducted in acetonitrile solution. A quenching rate constant, kq, of 1.05×1010M–1·s–1 was obtained with a short fluorescence lifetime of 347ps. The reaction rate constant, which is within the diffusion-limited regime, is activation-controlled. The rate constant of deactivation of the thermally excited curcumin was 1.2 orders of magnitude more nonradiative (2.67×109s–1) than radiative (2.16×108s–1). The reaction was exothermic with a G° of –1.97eV and solvent reorganization energy of 1.37eV. These values indicate that the electron transfer reaction is solvent-mediated with electron transfer rate constant, kET, of 2.16×1010s–1.  相似文献   

12.
Thallium in natural water samples was determined by electrothermal atomic absorption spectrometry after 1000-fold enrichment by mini solid-phase extraction from a 100-mL sample solution. A Tl-pyrrolidine-1-carbodithioate complex formed in a sample solution of pH 1.6 was extracted on fine particles of a cellulose nitrate resin dispersed in the sample solution. The cellulose nitrate resin was then collected on a membrane filter (25mmø) by filtration under suction using a glass funnel with an effective filtration area of 0.64cm2. As a result, a circular thin layer of the resin phase with a diameter of 9mm was obtained. Then the resin phase was carved out by an acrylate resin puncher with a 10-mmø hole to put it into a sample cup containing 100µL of 10mM HNO3 containing 0.5mM NaCl. The resin phase was suspended in the solution by ultrasonication. 1000-fold enrichment was thus attained within 15min, and the suspension was delivered to electrothermal atomic absorption spectrometry. The linear calibration graph was obtained in the range of 0–4ng of Tl in 100mL of a sample solution. The detection limit obtained by 3 method was 0.19ng. The proposed method was applied to the determination of Tl in natural water samples. The results showed the concentration of Tl in seawater was 12.1±1.8pgmL–1 for the calibration graph method and 12.6±1.4pgmL–1 for the standard addition method. A snowmelt sample contained 20.7±1.0pgmL–1 of Tl.  相似文献   

13.
A simple commercial graphite pencil electrode (GPE) was utilized for monitoring caffeine using the square-wave anodic stripping voltammetry (SWASV) method. This method was applied to determine the caffeine levels in several tea samples, which yielded a relative error of 1% in the concentrations. Caffeine was deposited at 0.0V (vs. Ag/AgCl), then reduced at +1.40V to strip it on the GPE. Optimal experimental conditions for the analysis were found to be as follows: pH value of 9 for the medium; deposition potential of 0.0V; deposition time of 120s; SW frequency of 25Hz; SW amplitude of 45mV, and step potential of 6mV. Given these optimum conditions, a linear range was observed within the concentration of 0500mgL–1. At caffeine concentrations of 50.0, 250.0, and 500.0mgL–1, the relative standard deviations in measured concentrations (n=12) were 0.19, 0.09, and 0.11%, respectively. The detection limit was found to be 9.2mgL–1, which is comparable with the result obtained using a carbon paste electrode, equivalent to 8.2mgL–1.  相似文献   

14.
In this study, a syringe-connected minicolumn resin was used for the separation and enrichment of cadmium, copper, nickel and zinc prior to their determination by flame atomic absorption spectrometry. The proposed technique was compared with classical batch and column techniques in terms of rapidness, simplicity, enrichment and risk of contamination. The minicolumn was filled with Chromosorb-103 resin and connected to a syringe. If the samples were treated with ammonium pyrrolidine dithiocarbamate or 8-hydroxyquinoline, the analytes were quantitatively retained at pH2 and pH5 on the resin, respectively. On the other hand, if no chelating agent was added, the analytes were quantitatively retained at pH10. The analytes retained by the resin were quantitatively eluted by drawing and discharging nitric acid in acetone. The analytes in spiked river-water samples and in certified standard reference Bovine-Liver (NIST SRM 1577 b) were quantitatively (94%) recovered. The relative standard deviations for the determinations were found to be 1.0–10%.  相似文献   

15.
A method for the determination of Fe(III), Co(II) and Cr(III) by flame atomic absorption spectrophotometry (FAAS) after preconcentrating on a column containing S. carlsbergensis immobilized on Amberlite XAD-4 has been developed. The optimum values of pH, amount of adsorbent, elution solution and flow rate of the sample solution were determined for the quantitative recovery of the analytes. The effect of interfering ions on the recovery of the analytes was also investigated. Under the optimum conditions, recoveries of Fe(III), Co(II) and Cr(III) by S. carlsbergensis immobilized on Amberlite XAD-4 were 99±2, 100±2 and 98±2% at 95% confidence level, respectively. The limit of detections for Fe(III), Co(II) and Cr(III) were 2.8, 3.9 and 7.4ngmL–1, respectively. The proposed method was applied to the determination of the analytes in various water samples. The validity of the method was checked with spiked water samples. Fe(III), Co(II) and Cr(III) was determined with a relative error of less than 5%.  相似文献   

16.
A new method of SS-RTP for the determination of trace silver has been established. This method is based on the fact that Ag+, when activated by ,-bipyridyl (bipy) in a media of HAc–NaAc (pH=4.9), can catalyze the reaction of Rhodamine B (RhoB) oxidized by K2S2O8, thus causing the Solid Substrate Room-Temperature Phosphorescence (SS-RTP) of RhoB to be quenched. The activating efficiency of bipy is 6.7 times higher than that of o-phenanthroline (phen). The reduction of the phosphorescence intensity (Ip) of RhoB is directly proportional to the concentration of Ag+ ions in the range of 1.6016.0agspot–1 (0.40µLspot–1). The regression equation of the working curve can be expressed as Ip=18.78+5.100mAg+ (agspot–1) (r=0.9994, n=6), the detection limit is 0.28agspot–1. This rapid, accurate and sensitive method has been successfully applied to the determination of trace silver in tea and human hair samples, and the results agree well with the Atomic Absorption Spectroscopy (AAS) method. The mechanism of the catalyzing reaction is also discussed.  相似文献   

17.
A simple, inexpensive method for determining nitrite is presented. With a carbon nanotube modified glass carbon electrode (GC), the overpotential for reduction of nitrite decreased, and direct reduction could be achieved in acid solution. Sensitivity, however, was not very high. When cupric ions were added to the solution, the reduction peak current increased significantly, and in particular the presence of multiple nitrate did not interfere. Experimental conditions were optimized, and preliminary studies were performed on the electrochemical mechanism of nitrite reduction in the presence of cupric ions on the carbon nanotube modified electrode. Under optimized conditions, the peak current of reduction achieved with the differential pulse voltammetric method was proportional to the concentration of nitrite in the ranges of 2.0×10–6–1.0×thinsp;10–5molL–1 and 2.0×10–5–1.0×10–3molL–1. The detection limit reached 5.0×10–7molL–1, and most of the inorganic ions did not interfere. The determination of nitrite in samples of rain water and river water was satisfactory.  相似文献   

18.
A novel electroanalytical method for the determination of physcion is described for the first time. Physcion yields an adsorption catalytic voltammetric peak at –0.74V (vs. SCE) in 0.4molL–1 NH4Cl–NH3·H2O buffer solution (pH 10.5) at a carbon paste electrode (CPE). The experimental results indicated that physcion is efficiently accumulated at a CPE by adsorption. In the subsequent potential scan, physcion was reduced to a homologous anthrahydroquinone compound. The compound was then immediately oxidized to physcion by the dissolved oxygen in the solution, and then physcion was again reduced at the CPE. As a result, a cyclic catalytic reaction was established. The second-order derivative peak current is proportional to the physcion concentration in the ranges of 2.0×10–104.0×10–9molL–1 (accumulation 90s) and 4.0×10–92.0×10–8molL–1 (accumulation 60s). The limit of detection is 8×10–11molL–1 (S/N=3) for a 120s accumulation time. The method was applied to the direct determination of physcion in the medicinal plant polygonum multiflorum Thumb with satisfactory results.  相似文献   

19.
Summary. The dissociation constants of the two oxime groups of 1,1-bis(pyridinium-4-aldoxime)trimethylene dibromide (TMB-4) were determined using spectrophotometric data. Two numerical methods were applied to treat the overlapping equilibria. The results obtained by both agreed with each other and their mean values at 25°C corrected for the ionic strength of 0.05moldm–3 are pKa1=7.49±0.11 and pKa2=8.96±0.09. These values were discussed in terms of the pKas of 1,1-bis(pyridinium-4-aldoxime)oxydimethylene dichloride (Toxogonin), a similar dioxime, which were derived by extrapolation of literature data.  相似文献   

20.
A simple and reliable electrochemical method for the determination of bismuth in water and nickel metal samples using a sodium montmorillonite (SWy-2) modified carbon paste electrode was described. Due to its strong cation-exchange ability and adsorptive characteristics, SWy-2 significantly enhances the sensitivity of determination for Bi3+. Bi3+ is firstly preconcentrated and then reduced on the modified electrode surface at –0.50V. After that, reduced bismuth is stripped from the electrode surface during the positive potential sweep of –0.50V to 0.20V, and a well-defined stripping peak at –0.12V appears. The stripping peak current is proportional to the concentration of Bi3+ from 4×10–9molL–1 to 1×10–6molL–1. The detection limit (signal-to-noise=3) is 1×10–10molL–1 after 5min. accumulation. The proposed method was successfully applied to the determination of bismuth in water and nickel metal samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号