共查询到20条相似文献,搜索用时 0 毫秒
1.
The feasibility of direct-immersion (DI) solid-phase microextraction (SPME) and headspace (HS) SPME for the determination of high-ring polycyclic aromatic hydrocarbons (PAHs) (4- to 6-ring PAHs) in water and soil samples is studied. Three SPME fibers--100- and 30-microm polydimethylsiloxane (PDMS) and 85-microm polyacrylate (PA) fibers-are compared for the effective extraction of PAHs. Parameters affecting the sorption of PAHs into the fiber such as sampling time, sampling volume, and temperature are also evaluated. The extracted amounts of high-ring PAHs decrease with the decreasing of film thickness, and the 100-microm PDMS has the highest extraction efficiency than 85-microm PA and 30-microm PDMS fibers. Also, the extraction efficiency decreases with the increasing molecular weights of PAHs. Of the 10 high-ring PAHs, only fluoranthene and pyrene can reach equilibrium within 120 min at 25 degrees C for DI-SPME in a water sample. Increasing the temperature to 60 degrees C can increase the sensitivity of PAHs and shorten the equilibrium time. A 0.7- to 25-fold increase in peak area is obtained for DI-SPME when the working temperature is increased to 60 degrees C. For HS-SPME, the extraction efficiency of PAHs decrease when the headspace volume of the sampling system increases. All high-ring PAHs can be detected in a water sample by increasing the temperature to 80 degrees C. However, only 4- and 5-ring PAHs can be quantitated in a CRM soil sample when HS-SPME is used. The addition of a surfactant with high hydrophilic property can effectively enhance the sensitivity of high-ring PAHs. HS-SPME as well as DI-SPME with 100-microm PDMS or 85-microm PA fibers are shown to be suitable methods for analyzing high-ring PAHs in a water sample; however, this technique can only apply in a soil sample for PAHs having up to 5 rings. 相似文献
2.
For the first time, the low-density solvent-based solvent demulsification dispersive liquid-liquid microextraction was developed for the fast, simple, and efficient determination of 16 priority polycyclic aromatic hydrocarbons (PAHs) in environmental samples followed by gas chromatography-mass spectrometric (GC-MS) analysis. In the extraction procedure, a mixture of extraction solvent (n-hexane) and dispersive solvent (acetone) was injected into the aqueous sample solution to form an emulsion. A demulsification solvent was then injected into the aqueous solution to break up the emulsion, which turned clear and was separated into two layers. The upper layer (n-hexane) was collected and analyzed by GC-MS. No centrifugation was required in this procedure. Significantly, the extraction needed only 2-3 min, faster than conventional DLLME or similar techniques. Another feature of the procedure was the use of a flexible and disposable polyethylene pipette as the extraction device, which permitted a solvent with a density lighter than water to be used as extraction solvent. This novel method expands the applicability of DLLME to a wider range of solvents. Furthermore, the method was simple and easy to use, and some additional steps usually required in conventional DLLME or similar techniques, such as the aforementioned centrifugation, ultrasonication or agitation of the sample solution, or refrigeration of the extraction solvent were not necessary. Important parameters affecting the extraction efficiency were investigated in detail. Under the optimized conditions, the proposed method provided a good linearity in the range of 0.05-50 μg/L, low limits of detection (3.7-39.1 ng/L), and good repeatability of the extractions (RSDs below 11%, n=5). The proposed method was successfully applied to the extraction of PAHs in rainwater samples, and was demonstrated to be fast, efficient, and convenient. 相似文献
3.
Headspace solvent microextraction and gas chromatographic determination of some polycyclic aromatic hydrocarbons in water samples 总被引:1,自引:0,他引:1
Headspace solvent microextraction (HSME) was shown to be an efficient preconcentration method for extraction of some polycyclic aromatic hydrocarbons (PAHs) from aqueous sample solutions. A microdrop of 1-butanol (as extracting solvent) containing biphenyl (as internal standard) was used in this investigation. Extraction occurred by suspending a 3 μl drop of 1-butanol from the tip of a microsyringe fixed above the surface of solution in a sealed vial. After extraction for a preset time, the microdrop was retracted back into the syringe and injected directly into a GC injection port. The effects of nature of extracting solvent, microdrop and sample temperatures, stirring rate, microdrop and sample volumes, ionic strength and extraction time on HSME efficiency were investigated and optimized. Finally, the enrichment factor, dynamic linear range (DLR), limit of detection (LOD) and precision of the method were evaluated by water samples spiked with PAHs. The optimized procedure was successfully applied to the extraction and determination of PAHs in different water samples. 相似文献
4.
For the first time, solid-phase extraction (SPE) has been combined to room-temperature phosphorimetry (RTP) to determine the 16 polycylic aromatic hydrocarbons related as major pollutants by the US Environmental Protection Agency (EPA). These include naphthalene, anthracene, acenaphthylene, acenaphthene, fluorene, fluoranthene, benzo(a)anthracene, benzo(k)fluoranthene, benzo(b)fluoranthene, benzo(a)pyrene, indeno(1,2,3-cd)pyrene, pyrene, chrysene, phenanthrene, benzo(g,h,i)perylene and dibenzo(a,h)anthracene. The pre-concentration factor obtained by SPE, combined with the sensitivity of RTP, resulted in calibration curves with linear dynamic ranges at the parts-per-billion level (ng ml(-1)). The limits of detection were estimated at the parts-per-trillion level (pg ml(-1)). Several pollutants usually encountered in water samples were tested for interference. These included polychlorinated biphenyls, pesticides, and volatile organic compounds. As a result of the appropriate combination of excitation wavelength (330 nm) and phosphorescence enhancers (0.1 M TlNO(3) and 0.05 M sodium dodecyl sulfate, SDS), no interference was observed. The results demonstrate the potential of SPE-RTP for screening polycyclic aromatic hydrocarbons (PAHs) in environmental waters. 相似文献
5.
A. V. Chuikin S. V. Grigor’ev A. A. Velikov 《Russian Journal of Physical Chemistry A, Focus on Chemistry》2006,80(2):307-309
A concentrator was designed for solid-phase microextraction of aromatic compounds (benzene, toluene, ethylbenzene, o-xylene) from water samples. The concentrator was used as an attachment to a water vapor mobile phase chromatograph with a detection limit (compounds <1 μg/l). 相似文献
6.
Meizhen Fu Hanzhu Xing Xiangfeng Chen Rusong Zhao Chunyi Zhi Chiman Lawrence Wu 《Analytical and bioanalytical chemistry》2014,406(24):5751-5754
Boron nitride nanotube (BNNT) is a novel material that shows potential ability in capturing organic pollutants. In this study, BNNTs fixed on a stainless steel fiber by a sol–gel technique were used as sorbent for solid-phase microextraction. Five polycyclic aromatic hydrocarbons with different numbers of aromatic rings were selected as target analysts. Gas chromatography coupled with tandem mass spectrometry was used for detection and quantitative determination. Under optimized conditions, the experimental results show a wide range of linearity (1 to 1,000 ng L?1), less than 10.1 % repeatability of relative standard deviation, and low detection limits (0.08 to 0.39 ng L?1). In addition, the fabricated fiber offered good thermal and chemical stability. The proposed method was successfully applied for the analysis of real water samples, and satisfactory results were obtained with relative recoveries ranging from 80.2 to 116.8 %. The results demonstrated that BNNTs could be used as sorbent for the analysis of environmental pollutants at trace levels. 相似文献
7.
For the first time, Vacuum Assisted Headspace Solid Phase Microextraction (Vac-HSSPME) is used for the recovery of polycyclic aromatic hydrocarbons (PAHs) from solid matrices. The procedure was investigated both theoretically and experimentally. According to the theory, reducing the total pressure increases the vapor flux of chemicals at the soil surface, and hence improves HSSPME extraction kinetics. Vac-HSSPME sampling could be further enhanced by adding water as a modifier and creating a slurry mixture. For these soil-water mixtures, reduced pressure conditions may increase the volatilization rates of compounds with a low KH present in the aqueous phase of the slurry mixture and result in a faster HSSPME extraction process. Nevertheless, analyte desorption from soil to water may become a rate-limiting step when significant depletion of the aqueous analyte concentration takes place during Vac-HSSPME. Sand samples spiked with PAHs were used as simple solid matrices and the effect of different experimental parameters was investigated (extraction temperature, modifiers and extraction time). Vac-HSSPME sampling of dry spiked sand samples provided the first experimental evidence of the positive combined effect of reduced pressure and temperature on HSSPME. Although adding 2 mL of water as a modifier improved Vac-HSSPME, humidity decreased the amount of naphthalene extracted at equilibrium as well as impaired extraction of all analytes at elevated sampling temperatures. Within short HSSPME sampling times and under mild sampling temperatures, Vac-HSSPME yielded linear calibration curves in the range of 1–400 ng g−1 and, with the exception of fluorene, regression coefficients were found higher than 0.99. The limits of detection for spiked sand samples ranged from 0.003 to 0.233 ng g−1 and repeatability from 4.3 to 10 %. Finally, the amount of PAHs extracted from spiked soil samples was smaller compared to spiked sand samples, confirming that soil could bind target analytes more strongly and thus decrease the readily available fraction of target analytes. 相似文献
8.
A solid-phase microextraction (SPME) and gas chromatography-mass spectrometry method for determining polycyclic aromatic hydrocarbons (PAHs) in environmental solid matrices is developed. Investigated matrices include seaweed (Undaria pinnatifida and Himanthalia elongata), humic substances (isolated from a wetland out-flow and purchased from Aldrich), and soil. Optimal conditions for a good SPME efficiency of 16 hydrocarbon compounds are obtained using a 100- micro m polydimethylsiloxane fiber directly immersed in aqueous carrier medium. The method is remarkable for presenting short extraction times and considerably high sensitivities. The SPME results obtained by using internal calibration give the total analyte concentration based on the identical partitioning behavior of native and spiked pollutants. The detection limits range from 0.001 to 0.1 mg of PAH per kilogram of dry matrix. SPME external calibration provides information regarding freely dissolved analytes. The detection limits range from 0.001 to 0.05 micro g of PAH per liter of carrier medium. The SPME with external calibration procedure can be applied to measure free concentrations of a target compound spiked into a carrier medium and onto a matrix. Based on a comparison of results obtained for the two samples, the partitioning of the target analyte between the matrix and the carrier medium is calculated. 相似文献
9.
In this study, the potential for carbonaceous nanomaterials to be used as adsorbents for the mixed matrix membrane (MMM) microextraction and preconcentration of organic pollutants was demonstrated. For this method, multiwall carbon nanotubes (MWCNT) and single layer graphene (SLG) nanoparticles were individually incorporated through dispersion in a cellulose triacetate (CTA) polymer matrix to form a MWCNT-MMM and SLG-MMM, respectively. The prepared membranes were evaluated for the extraction of selected polycyclic aromatic hydrocarbons (PAHs) present in sewage pond water samples. The extraction was performed by dipping a small piece of membrane (7 mm × 7 mm) in a stirred 7.5 mL sample solution to initiate the analyte adsorption. This step was followed by an analyte desorption into 60 μL of methanol prior to high performance liquid chromatography (HPLC) analysis. When the optimum SLG-MMM microextraction technique was applied to spiked sewage pond water samples, the detection limit of the method for the PAHs were in the range of 0.02–0.09 ng/mL, with relative standard deviations of between 1.4% and 7.8%. Enrichment factors of 54–100 were achieved with relative recoveries of 99%–101%. A comparison was also made between the proposed approach and standard solid phase extraction using polymeric bonded octadecyl (C18) cartridges. 相似文献
10.
Air/polymer distribution coefficients for polycyclic aromatic hydrocarbons by solid-phase microextraction sampling 总被引:2,自引:0,他引:2
Two methods to estimate distribution coefficients (K) between air and poly(dimethylsiloxane) (PDMS) coating of solid-phase microextraction (SPME) fibers for eight low molecular polycyclic aromatic hydrocarbons (PAHs) there are presented. The PDMS phases were used for determination of the coefficients according to equilibrium theory with help of a developed static calibration system (SCS). Another way to estimate the coefficients is based on the use of a linear relationship between the logarithm of the coefficients (log K) and linear temperature-programmed retention indexes (LTPRI) of the compounds without necessity to calibrate. The log K values for both of methods ranged from 5.2 (naphthalene) to 8.9 (pyrene) at 22 degrees C. Relative standard deviation (R.S.D.) of log K for each compound determined by static calibration was no more than 5.3%. R.S.D. of retention times for LTPRI indices did not exceed 0.28% for repeated injection. All experiments were implemented on a GC-MS system. 相似文献
11.
Micro-solid-phase extraction (μ-SPE) was developed for the determination of trace level of 16 United States Environmental Protection Agency priority polycyclic aromatic hydrocarbons (PAHs) in river water samples with gas chromatography-mass spectrometry (GC-MS). In the μ-SPE device, multiwalled carbon nanotubes was employed as sorbent and was packed inside an porous polypropylene membrane "envelope" whose edges were heat-sealed to secure the contents. The μ-SPE device was placed in a stirred sample solution to extract the analytes. The porous polypropylene membrane envelope in μ-SPE device acts as a filter to exclude potential interferences, such as eliminating or reducing the influence of particles that are bigger than the pore size. After extraction, analyte desorption was carried out with a suitable organic solvent under ultrasonication. Important extraction parameters were optimized in detail, including the selection and amount of sorbent materials, the extraction temperature and extraction time, desorption solvent and desorption time, amount of organic modifier, agitation speed and sample ionic strength. Under the developed extraction conditions, the proposed method provided good linearity in the range of 0.1-50 μg/L, low limits of detection (4.2-46.5 ng/L), and good repeatability of the extractions (relative standard deviations, <12%, n=5). The developed μ-SPE method was successfully applied to the extraction of PAHs in river water samples. The μ-SPE method was demonstrated to be a fast and efficient method for the determination of PAHs from environmental water samples. 相似文献
12.
A. Yu. Ryabov A. V. Chuikin A. A. Velikov 《Russian Journal of Physical Chemistry A, Focus on Chemistry》2016,90(6):1261-1264
The results of our study of solid-phase microextraction of substances using a centrifuge for determining the microquantities of hydrocarbon impurities in water are presented. The cartridge diameter, sorbent mass, and solvent volume were shown to affect the percent extraction of substances and the analytical signal intensity. The relationship between the cartridge geometry, the sorbent mass, and the solvent volume was considered. 相似文献
13.
The capabilities of using boron-doped diamond (BDD) thin films as electrode materials for analysis of the 16 US Environmental Protection Agency (EPA) priority polyaromatic hydrocarbons (PAHs) after a liquid chromatographic separation were evaluated. The BDD electrode was able to detect all 16 PAHs with high sensitivity due to the low background current and wide potential window. The method provided detection limits ranging from 12-40 nM (3-10 ppb) and repeatable results over consecutive analysis. Calibration curves were linear up to at least 10 microM for all PAHs. The work shows the promising use of diamond as an amperometric detector in high performance liquid chromatography (HPLC), especially for PAHs and other hydrophobic aromatic compounds. 相似文献
14.
A new method by combining headspace single drop microextraction (HS-SDME) with HPLC fluorescence detection for the determination of trace polycyclic aromatic hydrocarbons (PAHs) in environmental samples was developed. Aqueous solution of saturated beta-cyclodextrin was used as extraction solvent and five PAHs were employed as target analytes. The factors affecting the extraction efficiency were studied in detail and the optimal extraction conditions were established. Beta-cyclodextrin was found to play two important roles, one is the improvement of extraction efficiency of target analytes and the other is the enhancement of their fluorescence intensities in HPLC fluorescence detection. The detection limits for the target analytes were found to be in the range of 0.004-0.247ng/ml and the relative standard deviations (R.S.D.s) of 5.1-7.1% were obtained. The proposed method was applied to the analysis of trace PAHs in environmental samples with satisfactory results. 相似文献
15.
M. A. Rodríguez Delgado R. Corbella Tena F. J. García Montelongo 《Chromatographia》1999,50(3-4):235-238
Summary An HPLC method with UV and programmed fluorescence detection has been optimized and used to evaluate the levels of contamination of PAHs in lightly contaminated biota samples. A specific stationary phase was used that offers high selectivity for PAH separation. The proposed method was applied to limpet samples from Fuerteventura (Canary Island) with good results. 相似文献
16.
Levinson J Sluszny C Yasman Y Bulatov V Schechter I 《Analytical and bioanalytical chemistry》2005,381(8):1584-1591
It is estimated that most polycyclic aromatic hydrocarbons (PAHs) in environmental water are not dissolved but rather in particulate form. Nevertheless, the currently available optical detectors are not suited for proper sampling of solid PAHs. A new setup for direct sampling and quantification of suspended particulate PAHs in water is suggested. It is based on a polymeric film that has the capability of dissolving PAH particulates, coupled to a traditional laser-induced fluorescence probe. Kinetics and performance of two sampling modes have been studied: bulk sampling, by immersing the probe into the water, and surface sampling, by laying the film on the water surface. The latter method has proved to be more sensitive; however, it is diffusion-limited. Linear calibration plots have provided quantification over a wide concentration range with detection limits in the ppb range (these could be improved by using a modified probe). The effects due to other particulates in water have been studied and only little interferences have been observed. The possibility of analysis of PAH mixtures has been addressed and it has been concluded that multivariate analysis is needed. 相似文献
17.
Determination of polycyclic aromatic hydrocarbons in water by solid-phase microextraction and liquid chromatography. 总被引:5,自引:0,他引:5
Hong-Wen Chen 《Analytical sciences》2004,20(10):1383-1388
This study describes the determination of polycyclic aromatic hydrocarbons (PAHs) in water using high-performance liquid chromatography (HPLC) coupled with fluorescence detection (FLD). Because individual PAHs are generally present in water only at trace levels, a sensitive and accurate determination technique is essential. The separation and detection of five PAHs were run completely within 25 min by the HPLC/FLD system with an analytical C18 column, a fluorescence detection, and acetonitrile-water gradient elution. Calibration graphs were linear with very good correlation coefficients (r > 0.9998), and the detection limits were in the range of 2-6 ng/l for five PAHs. Solid phase microextraction (SPME) was performed for sample pretreatment prior to HPLC-FLD determination, and the governing parameters were investigated. Compared to conventional methods, SPME has high recovery, saves considerable time, and reduces solvents waste. The extraction efficiencies of five PAHs were above 88% and the extraction times were 35 min in one pretreatment procedure. One particular discovery is that 1.5 M sodium monochloroactate (ClCH2COONa) can improve the extraction yield of PAH compounds more than other inorganic salts. The SPME-HPLC-FLD technique provides a relatively simple, convenient, practical procedure, which was here successfully applied to determine five PAHs in water from authentic water samples. 相似文献
18.
Determination of sixteen polycyclic aromatic hydrocarbons in aqueous and solid samples from an Italian wastewater treatment plant 总被引:14,自引:0,他引:14
A robust procedure for the determination of 16 US EPA PAHs in both aqueous (e.g. wastewaters, industrial discharges, treated effluents) and solid samples (e.g. suspended solids and sludge) from a wastewater treatment plant (WWTP) is presented. Recovery experiments using different percentages of organic modifier, sorbents and eluting solvent mixtures were carried out in Milli-Q water (1000 mL) spiked with a mixture of the PAH analytes (100 ng/L of each analyte). The solid phase extraction (SPE) procedures applied to spiked waste water samples (1000 mL; 100 ng/L spiking level) permitted simultaneous recovery of all the 16PAHs with yields >70% (6-13% RSD). SPE clean up procedures applied to sewage and stabilized sludge extracts, showed percent recoveries in the range 73-92% (7-13% RSD) and 71-89% (7-12% RSD), respectively. The methods were used for the determination of PAHs in aqueous and solid samples from the WWTP of Fusina (Venice, Italy). Mean concentrations, as the sum of the 16PAHs in aqueous and suspended solid samples, were found to be approx. in the 1.12-4.62 microg/L range. Sewage and stabilized sludge samples contained mean PAH concentrations, as sum of 16 compounds, in the concentration range of 1.44-1.26 mg/kg, respectively. Extraction and clean up procedures for sludge samples were validated using EPA certified reference material IRM-104 (CRM No. 912). Instrumental analyses were performed by coupling HPLC with UV-diode array detection (UV-DAD) and fluorescence detection (FLD). 相似文献
19.
The effect of humic acid on solid-phase extraction of polycyclic aromatic hydrocarbons (PAHs) from surface water was studied. The hydrophobic PAHs show significant association with humic acid, and this was confirmed to be the cause of negative effect when conventional reversed-phase solid-phase extraction (RP-SPE) was employed to extract the analytes from aqueous samples. As an alternative, dynamic ion-exchange (DIE) SPE could simultaneously extract both the fraction of the analytes which was associated with humic acid, and that which was freely dissolved. Using the 16 US Environmental Protection Agency priority PAHs as model compounds, the recoveries of the highly hydrophobic components by DIE-SPE were 10-30% higher than those by RP-SPE for a 1000-ml water sample dissolved with Aldrich humic acid (of 4.1 mg/l dissolved organic carbon content). A similar result was also obtained for 500 ml of natural surface water although the difference in recoveries between the two methods for this sample was smaller than that for the simulated sample. For validation of the method, the artifacts in connection with DIE-SPE in extracting the fraction of analytes which was freely dissolved and that which was associated with humic acid were investigated. 相似文献
20.
Solid-phase microextraction versus single-drop microextraction for the analysis of nitroaromatic explosives in water samples. 总被引:1,自引:0,他引:1
This paper compares solid-phase microextraction (SPME) with a recently developed extraction method called single-drop microextraction (SDME) for the analysis of nitroaromatic explosives in water samples. The two techniques are examined in terms of procedure, chromatographic analysis and method performance. All practical considerations for both techniques are also reviewed. SPME requires dedicated apparatus and is relatively expensive, as the fiber's lifetime is limited. However, it has the advantages over SDME that it can be easily used for headspace analysis and has lower detection limits for all the target analytes. SDME requires more elaborate manual operations, thus affecting linearity and precision. 相似文献