首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A method for determining Diazepam and its associated compounds in pharmaceutical products by micellar electrokinetic chromatography (MEKC) is described. The separation was carried out at 30 °C and 25 kV, using a 25 mM borate buffer (pH 9.6) and 35 mM sodium dodecylsulfate (SDS) water solution. Under these conditions the analysis was carried out within 12 min with acceptable limits of detection and quantification. The method has been applied for quantifying Diazepam in different commercial formulations when it is the active drug and when it is employed associated with other drugs (Nortriptyline, Pyridoxine hydrochloride and Sulpiride). Received: 30 October 1998 / Revised: 1 February 1999 / Accepted: 3 February 1999  相似文献   

2.
A method for quantifying of ethinylestradiol (ETE) and levo-norgestrel (LEV) in pharmaceutical products by micellar electrokinetic chromatography (MEKC) is described. The separation was carried out at 25 degrees C and 25 kV, using a 20 mM borate buffer (pH 9.2), 15 mM sodium dodecylsulfate (SDS) in 30% acetonitrile/water (v/v). Under these conditions the analysis takes about 7 min. The method has been applied for quantifying both compounds in six different commercial contraceptives and the proposed method gave good results when compared with a reference liquid chromatographic (LC) method.  相似文献   

3.
Summary A micellar electrokinetic chromatographic method is presented which permits quantification of ethinylestradiol and gestodene in pharmaceutical products. Separation was carried out at 25°C and 25 KV, using a 20 mM borate buffer (pH 9.2), 15 mM sodium dodecylsulfate in 30% acetonitrile-water (v/v). Under these conditions analyses were carried out in 7 min. Four different oral contraceptives were analysed and the results compared favourably with those of a reference liquid chromatographic method.  相似文献   

4.
The separation of four benzodiazepines (Flurazepam, Flunitrazepam, Clobazam and Clorazepate) in pharmaceutical products by micellar electrokinetic chromatography (MEKC) is described. It was carried out at 25 degrees C and 25 kV by using a 57 cm (50 cm to the detector)x75 mum i.d. fused silica capillary and a 15 mM borate buffer (pH 9.2), 35 mM sodium dodecylsulfate (SDS) and 35 mM sodium deoxycholate water solution. Under these conditions, the analysis was performed in 8 min with acceptable limits of quantification (between 3 and 5 mg l(-1)). The method has been applied for quantifying these benzodiazepines in serum and different commercial formulations with recoveries near 100%.  相似文献   

5.
A new method has been developed for the monitoring of glutathione S-tranferase (GST) detoxification activity toward styrene oxide (SO). The enzymatic reaction was carried out directly in a thermostatted autosampler vial and the formation of conjugates between glutathione (GSH) and SO was monitored by sequential MEKC runs. The determinations were performed in a 50-microm fused silica capillary using 50 mM SDS in 20 mM phosphate 20 mM tetraborate buffer (pH 8.3) as a background electrolyte; separation voltage 28 kV (positive polarity), temperature of capillary 25 degrees C, and detection at 200 nm. The method is rapid, amenable to automation, and requires only small amounts of samples, which is especially important in the case of GST isoenzyme analyses.  相似文献   

6.
Capillary zone electrophoresis with indirect UV detection at 215 nm was applied for the separation and determination of mannitol (MA), sorbitol (SO) and xylitol in the form of anionic borate-polyol complexes. The separation was carried out in a fused silica capillary (total length 60 cm, effective length 50 cm, I.D. 50 microm) at 25 kV. The optimized background electrolyte was 200 mM borate buffer (pH 9.3, adjusted with triethylamine) containing 10 mM 3-nitrobenzoate as the chromogenic co-ion. The separation took approximately 13 min. The rectilinear calibration range was 0.2-2 mg mL(-1) for MA and SO when using xylitol (1 mg mL(-1)) as the internal standard. The limit of detection at a S/N of 3 was approximately 30 microg mL(-1) for either analyte. The method was used for the assay of MA or SO in pharmaceutical infusion solutions. The RSD values were 0.15% or 1.07% (n=6) when determining 100 mg mL(-1) of MA or 50 mg mL(-1) of SO in commercial infusion solutions. The results were in good agreement with those of pharmacopoeial iodimetric titration.  相似文献   

7.
A method for the determination of isoniazid (ISO), pyrazinamide (PYR) and rifampicin (RIF) in pharmaceutical products, by micellar electrokinetic capillary chromatography (MEKC) with ultraviolet detection is described. The influence of pH, concentration of surfactants, buffer and organic solvents, over the separation were studied as experimental variables. The optimal separation was carried out at 30 degrees C and 20 kV, using a 40 mM borate buffer and 100 mM sodium dodecylsulphate (SDS) adjusted to pH 8.5. Under these conditions, the analysis is accomplished in about 8 min. The method was applied to the determination of these compounds in different pharmaceuticals with good results when compared with a reference liquid chromatographic (LC) method.  相似文献   

8.
Fanali S  Pucci V  Sabbioni C  Raggi MA 《Electrophoresis》2000,21(12):2432-2437
In modern practice, the treatment of Parkinson's disease and syndrome is carried out using pharmaceutical formulations containing a combination of levodopa and a decarboxylation inhibitor (carbidopa or benserazide). Two pharmaceutical formulations were quantified by capillary zone electrophoresis using two procedures which differed only in the kind of background electrolyte used. One procedure used a 25 mM phosphate buffer, pH 2.5, while the second one used a 25 mM borate buffer, pH 8.5. The electrophoretic analysis was carried out using an uncoated fused- silica capillary, a separation voltage of 20 kV with currents typically less than 60 microA, and spectrophotometric detection at 205 nm. Calibration curves were performed for levodopa (concentration range 1-100 microg/mL), for carbidopa and benserazide (1-50 microg/mL), and the plots of the peak area versus concentration were found to be linear with a correlation coefficient better than 0.9990. Satisfactory results were obtained when commercial tablets were analyzed in terms of accuracy (98-102%), repeatability (0.6-2.0%), and intermediate precision (1.1-2.6%).  相似文献   

9.
A sensitive, simple, and reliable high-performance liquid chromatographic method with electrochemical detection is developed for the measurement of four natural products, the serotonin-related indols from human platelet-rich plasma (PRP) using N-methylserotonin as internal standard. Separation of serotonin (5HT), 5-hydroxytryptophan (5HTP), 5-hydroxytryptophol (5HTOL), and 5-hydroxyindole-acetic acid (5HIAA) is carried out on Supelcosil LC-18DB stationary phase. A mixture of 48mM citric acid, 28mM sodium phosphate dibasic, 0.027mM Na(2)EDTA, and 3% methanol (pH 3.18) serves as the mobile phase. Measurements are carried out at 25 degrees C at E(ox) = 0.65 V. The calibration curves are linear through the range of 10-200 pg/mL. Method validation is performed according to internationally accepted criteria. Blood is collected from healthy controls and schizophrenic subjects. Significantly higher PRP serotonin is measured in schizophrenics; patients with recent alcohol consumption could be characterized with significantly elevated 5HTOL/5HIAA ratio.  相似文献   

10.
An ammonia-specific and rapid fluorometric method for determination of ammonia and urease activity was developed. The method is designed to assay ammonia levels or urease activity for the rapid diagnosis of Helicobacter pylori infection. 4-Fluoro-7-nitrobenzo-2-oxa-1,3-diazole was used to derivatize ammonia and 4-amino-7-nitrobenzo-2-oxa-1,3-diazole was analysed by high performance liquid chromatography at an excitation wavelength of 455 nm and an emission wavelength of 520 nm. Derivatization was designed to react with ammonia gas produced in a strong alkaline pH sample. The fluorescent intensity was linear in the range of 0.1-10 mM ammonia per tube when the reaction was carried out for 15 min at 37 degrees C. Urease activity, judged as the amount of ammonia production from urea, could be measured at 25 ng per tube (S/N = 1.5) with Jack bean meal urease. Because of its rapidity, this assay is potentially superior to the current standard method in use in clinical settings.  相似文献   

11.
A micellar electrokinetic chromatography (MEKC) method was validated for the analysis of ezetimibe. The method was carried out on a fused-silica capillary (50 microm i.d.; effective length, 40 cm). The background electrolyte consisted of a 25 mM borate buffer and 25 mM anionic detergent SDS (pH 9.75)/methanol (90:10, v/v). The capillary temperature was maintained at 35 degrees C, the applied voltage was 30 kV; the injection was performed using a pressure mode at 50 mbar for 5 s, with detection at 232 nm. The method was linear in the range of 2-150 microg/mL (R2=0.9999). The specificity and the stability-indicating capability were proven through degradation studies, which also showed that there was no interference of the excipients. The limits of quantitation and detection were 2 and 0.41 microg/mL, respectively. The method was applied for the analysis of ezetimibe pharmaceutical formulations, and the results were compared to those of the liquid-chromatography method.  相似文献   

12.
In this paper, the separation of tetramethyl ammonium hydroxide (TMAH) from synthetic liquid wastes of electronic industry is carried out by using a micellar enhanced ultrafiltration (MEUF) process. This treatment represents the first step of an integrated process, aimed at the recovery of TMAH and surfactant and water reuse. The laboratory tests are carried out with an ultrafiltration module using initial solutions having a concentration of pollutant equal to 2?g/L and by adding sodium dodecyl sulfate as a surfactant, at a concentration in the range 4–10?mM/L, that is, under and above its critical micellar concentration (CMC). The experiments have been carried out at a fixed temperature of 25°C. The obtained results showed that very good percentage removals of TMAH are achieved (99%), especially when the surfactant was above the CMC.  相似文献   

13.
An interlaboratory pilot study was performed to determine the reproducibility of mobility parameters in capillary zone electrophoresis (CZE) and micellar electrokinetic chromatography (MEKC). The study was performed by an intended small number of laboratories (three) that used different brands of instruments (two). The effective mobility was corrected using standards by a method that was recently introduced to obtain a more reproducible migration parameter. A test set of 20 acidic test compounds and 5 reference compounds were analyzed during five days in each laboratory using CZE and MEKC. Buffers used consisted of 90 mM borate set at pH 8.4 (CZE) and 20 mM phosphate, 50 mM sodium dodecyl sulfate set at pH 7.5 (MEKC). Analyses were carried out using fused-silica capillaries at an electric field strength of either 52.6 kV/m or 37.5 kV/m. The interlaboratory reproducibility (mean RSD) of the effective mobility was 3.0% for CZE and 6.7% for MEKC. After applying the correction method, these values became 3.0% for CZE and 3.3% for MEKC, which is adequate for systematic toxicological analysis (STA) applications. A significant improvement of reproducibility for the calculated corrected effective mobility mu(eff)c was observed when variations are high. Therefore, it is recommended to use the correction method in interlaboratory situations, especially when instruments and capillaries from different manufacturers are used.  相似文献   

14.
A method is described for quantitating caffeine, theobromine, theophylline, paracetamol, propyphenazone, acetylsalicylic acid, salicylic acid, and codeine phosphate in corresponding real samples of food, beverages, natural products, pharmaceuticals, and cosmetic preparations by micellar electrokinetic capillary chromatography. The separation is carried out at 25 degrees C and 25 kV, using a 20mM phosphate buffer (pH 9.0), 80mM sodium dodecyl sulfate, and 7.5% (v/v) acetonitrile. UV detection is at 210 nm. The method is shown to be specific, accurate (recoveries over the range 98.9-101.2%), linear over the tested range (correlation coefficients >/= 0.9993), and precise (relative standard deviation below 2.1%). The method is applied for the quantitative analysis of these compounds in different foods, beverages, natural products, pharmaceuticals, and cosmetic products.  相似文献   

15.
A new sensitive method has been developed for the determination of haloalkane dehalogenase activity. The enzymatic reactions were carried out directly in thermostatted autosampler vials and the formation of product - bromide or chloride ions - was monitored by sequential capillary zone electrophoresis runs. The determinations were performed in a 75 microm fused-silica capillary using 5 mM chromate, 0.5 mM tetradecyltrimethylammonium bromide (pH 8.4) as a background electrolyte, separation voltage 15 kV (negative polarity) and indirect detection at sample wavelength 315 nm, reference wavelength 375 nm for brominated and chlorinated substrates, respectively 0.1 M beta-alanine-HCl (pH 3.50) as a background electrolyte, separation voltage 18 kV (negative polarity) and direct detection at 200 nm for brominated substrates. The temperature of capillary was in both cases 25 degrees C. The method is rapid, can be automated, and requires only small amount of enzyme preparation and substrate.  相似文献   

16.
Two capillary electrophoresis (CE) methods were evaluated for their suitability in systematic toxicological analysis (STA). A test set of 25 barbiturates was analysed using capillary zone electrophoresis (CZE) and micellar electrokinetic chromatography (MEKC). Buffers used consisted of 90 mM borate set at pH 8.4 (CZE) and 20 mM phosphate, 50 mM sodium dodecyl sulphate set at pH 7.5 (MEKC). All analyses were carried out using fused silica capillaries using an electric field strength of 52.6 kV/m. The use of a reproducible identification parameter is very important in STA as it influences the identification power (IP). To deal with the poor reproducibility of the migration time, we introduced the corrected effective mobility. Inter-day reproducibilities of the latter parameter were < 0.6% for CZE and < 0.5% for MEKC, using daily prepared buffers. The IP of the methods was expressed by calculation of the discriminating power and the mean list length. Data obtained were compared to gas chromatographic and high-performance liquid chromatographic data, and correlations between all methods were calculated. It was shown that little correlation exists between chromatographic and electrophoretic techniques. The results indicated that CE has a good identification power for the application in STA, especially when a combination of methods having a low correlation is used.  相似文献   

17.
Summary A new, rapid and simple method is described and applied to resolve and quantify mixtures of prednisolone, Zn-bacitracin and phenylephrine. The determination was accomplished by MEKC. The separation was carried out at 25 °C and 30 kV, using a 5 mM phosphate-5 mM borate buffer (pH=8.2), 40 mM SDS as background electrolyte. Under these conditions, the run time was 6.6 min and the limits of quantification were about 1.0 mg L–1 for every component. Repeatability and reproducibility studies were achieved showing no significant differences at 95% confidence level. The MEKC method has been applied for quantifying these compounds in different commercials pharmaceuticals products, without separations steps.  相似文献   

18.
Capillary GC and HPLC of metal chelates of pentamethylene dithiocarbamate were examined. Copper(II), nickel(II), cobalt(III), iron(III), manganese(II) and chromium(III) chelates formed in slightly acidic media (pH 5) were extracted in methyl isobutyl ketone or chloroform. Capillary GC elution and separation was carried out on methylsilicone DB-1 column (25 m x 0.2 mm I.D.) with film thickness 0.25 microm. Electron-capture detection was used. Elution was carried at initial column temperature 200 degrees C with an increment at a rate of 5 degrees C/min up to 250 degrees C and maximum temperature was maintained for 10 min. Symmetrical peaks with baseline separation were obtained with the metal chelates investigated with linear calibration range between 5 and 25 microg/ml for each metal ion and detection limits in the range of 0.5-6.0 microg/ml corresponding to 27-333 pg of metal ion reaching to the detector. HPLC separation was carried out from LiChrosorb ODS, 5 microm column and complexes eluted with methanol-water-1 mM sodium acetate (70:28:2, v/v) with a flow-rate of 1.2 ml/ml. UV detection was at 260 nm. The detection limits obtained were in the range 2-6 microg/ml. The methods were applied to the determination of metal ions in canal water and coal samples with RSD values within 4.15%. The results when compared with a standard flame atomic absorption spectrophotometric method and revealed no significant difference.  相似文献   

19.
Reversed‐phase and size‐exclusion liquid chromatography methods were validated for the assessment of streptokinase. The reversed‐phase method was carried out on a Jupiter C4 column (250 mm × 4.6 mm id) maintained at 25°C. The mobile phase consisted of 50 mM sodium sulfate solution pH 7.0 and methanol (90:10, v/v), run isocratically at a flow rate of 0.8 mL/min. The size‐exclusion method was carried out on a Protein KW 802.5 column (300 mm × 8.0 mm id), at 25°C. The mobile phase consisted of 40 mM sodium acetate solution pH 7.0, run isocratically at a flow rate of 1.0 mL/min. Retention times were 19.3 min, and 14.1 min, and calibration curves were linear over the concentration range of 0.25–250 μg/mL (25.75–25 750 IU/mL) (r 2 = 0.9997) and 5–80 μg/mL (515–8240 IU/mL) (r 2 = 0.9996), respectively, for reversed‐phase and size exclusion, with detection at 220 and 204 nm. Chromatographic methods were employed in conjunction with the in vitro bioassay for the content/potency assessment of Streptokinase, contributing to improve the quality control and ensure the efficacy of the biotherapeutic.  相似文献   

20.
反相高效液相色谱法测定犬血清及组织中的维拉帕米   总被引:1,自引:0,他引:1  
建立了动物血清、肝组织中维拉帕米(verapamil,VRPM)药物浓度的测定方法。 应用反相高效液相色谱法,以安定为内标,采用峰高内标法计算结果。流动相为醋酸盐缓冲液-甲醇-三乙胺(体积比为40∶60∶1)混合溶液,流速1.0 mL/min;检测波长228 nm。 VRPM在犬血清和肝组织中最低检测限分别为50 μg/L和50 ng/g。犬血清和肝组织匀浆中的VRPM质量浓度为0.1~10.0 mg/L及0.25~10.0 μg/g时,该浓度与响应值线性关系良好(r>0.999)。犬血清和肝组织匀浆中的  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号