首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 984 毫秒
1.
A method for determination of lead, cadmium, zinc, copper, and iron by atomic absorption spectrometry (AAS) after microwave digestion was subjected to a collaborative study in which 16 laboratories participated [including users of inductively coupled plasma (ICP) and ICP-mass spectrometry (MS)]. The types of samples included in the study were minced fish, wheat bran, milk powder, bovine and pig liver, mushroom, 2 simulated diets, and bovine muscle; the last 4 were certified reference materials. These were analyzed as single (4 samples), double blind (1 sample), or split level (2 samples) samples. Before the collaborative study, a pretrial was conducted in which 4 ready-made solutions and one fish tissue sample were analyzed for Pb and Cu. The reproducibility relative standard deviation (RSDR) values, for results above the detection limit, ranged from 59% at 0.155 mg/kg to 16% at 1.62 mg/kg for Pb, from 28% at 0.0124 mg/kg to 11% at 0.482 mg/kg for Cd, from 9.3% at 35.3 mg/kg to 1.7% at 147 mg/kg for Zn, from 39% at 0.241 mg/kg to 3.0% at 63.4 mg/kg for Cu, and from 17% at 7.4 mg/kg to 5.9% at 303 mg/kg for Fe. The RSDR values agreed well with the norms described by the International Union of Pure and Applied Chemistry. As a complement to the AAS determinations, a number of laboratories analyzed the samples either by ICP or by ICP-MS. The results of these analyses agreed well with the AAS results. On the basis of the results of the collaborative study, the method was adopted Official First Action by AOAC INTERNATIONAL.  相似文献   

2.
Due to the increased demand for new reference materials certified for total and methylmercury (MeHg) a sample of mussel homogenate (IAEA-142) has been prepared. Thirteen experienced laboratories reported results for total Hg of which 9 laboratories also reported results for MeHg content. Laboratories reporting MeHg results used various isolation techniques (solvent extraction, saponification, acid leaching, ion-exchange separation, and distillation) and detection systems (cold vapour atomic absorption spectrometry (CV AAS), cold vapour atomic fluorescence spectrometry (CV AFS), gas chromatography with electron capture detector (GC/ECD) and HPLC with CV AAS detector). In the case of total Hg, most of the laboratories used acid digestion, only two used alkaline dissolution, followed either by CV AAS or CV AFS. One laboratory used neutron activation analyses with radiochemical separation. The data received were in good agreement. The value for total Hg was certified to be 126 ng/g, with a 95% confidence interval from 119 to 132 ng/g. For MeHg the certified value of 47 ng/g expressed as Hg was assigned, with a 95% confidence interval from 43 to 51 ng/g. Stability testing has shown that both total and MeHg are stable if samples are stored in a dry and dark place at room temperature. The sample is now available as a certified reference material and is, in particular, useful for quality control measurements of Hg and MeHg in mussel samples at low concentration levels.  相似文献   

3.
Due to the increased demand for new reference materials certified for total and methylmercury (MeHg) a sample of mussel homogenate (IAEA-142) has been prepared. Thirteen experienced laboratories reported results for total Hg of which 9 laboratories also reported results for MeHg content. Laboratories reporting MeHg results used various isolation techniques (solvent extraction, saponification, acid leaching, ion-exchange separation, and distillation) and detection systems (cold vapour atomic absorption spectrometry (CV AAS), cold vapour atomic fluorescence spectrometry (CV AFS), gas chromatography with electron capture detector (GC/ECD) and HPLC with CV AAS detector). In the case of total Hg, most of the laboratories used acid digestion, only two used alkaline dissolution, followed either by CV AAS or CV AFS. One laboratory used neutron activation analyses with radiochemical separation. The data received were in good agreement. The value for total Hg was certified to be 126 ng/g, with a 95% confidence interval from 119 to 132 ng/g. For MeHg the certified value of 47 ng/g expressed as Hg was assigned, with a 95% confidence interval from 43 to 51 ng/g. Stability testing has shown that both total and MeHg are stable if samples are stored in a dry and dark place at room temperature. The sample is now available as a certified reference material and is, in particular, useful for quality control measurements of Hg and MeHg in mussel samples at low concentration levels. Received: 24 September 1996 / Revised: 20 November 1996 / Accepted: 8 December 1996  相似文献   

4.
The methylmercury content in two new marine bivalve mollusk tissue Standard Reference Materials (SRMs) has been certified using results of analyses from the National Institute of Standards and Technology (NIST) and two other laboratories. The certified concentrations of methylmercury were established based on the results from four and six different (independent) analytical methods, respectively, for SRM 1566b Oyster Tissue (13.2 ± 0.7 μg/kg) and SRM 2977 Mussel Tissue (organic contaminants and trace elements) (36.2 ± 1.7 μg/kg). The certified concentration of methylmercury in SRM 1566b is among the lowest in any certified reference material (CRM).  相似文献   

5.
An inter-laboratory comparison study for cortisol in saliva is reported in the present study. Nine laboratories representing four different methods participated in the study. Each laboratory measured five blind samples prepared from natural saliva spiked with a pure certified reference material in the range 0–70 nmol/L. The average observed values were established as means of eight laboratories, because one laboratory was excluded as an outlier. The natural content of cortisol in the pooled saliva was 6.8 nmol/L. The recovery of the certified reference material was 83%–131% (164% for the outlying laboratory). For five laboratories the 95%-confidence intervals of the recoveries did not cover 100%. The standard deviations for a concentration of 10 nmol/L were estimated for each laboratory. They were 0.64–1.67 nmol/L (6.26 nmol/L for the outlying laboratory). The present study emphasizes the need for an external proficiency-testing scheme and a certified reference material for cortisol in saliva. Received: 8 May 2002 Accepted: 3 September 2002  相似文献   

6.
The methylmercury content in two new marine bivalve mollusk tissue Standard Reference Materials (SRMs) has been certified using results of analyses from the National Institute of Standards and Technology (NIST) and two other laboratories. The certified concentrations of methylmercury were established based on the results from four and six different (independent) analytical methods, respectively, for SRM 1566b Oyster Tissue (13.2 +/- 0.7 microg/kg) and SRM 2977 Mussel Tissue (organic contaminants and trace elements) (36.2 +/- 1.7 microg/kg). The certified concentration of methylmercury in SRM 1566b is among the lowest in any certified reference material (CRM).  相似文献   

7.
A liquid chromatographic (LC) method for the determination of total taurine in pet foods was evaluated in a collaborative study. Ten laboratories assayed 6 blind duplicate pairs of wet and dry pet foods. The taurine in the 6 sample pairs ranged from low (170 mg/kg) to high (2250 mg/kg) concentrations as is. Collaborators also assayed a sample of known taurine concentration for familiarization purposes. Samples were hydrolyzed to release bound taurine, which was subsequently converted to the dansyl derivative and quantitated by gradient-elution LC with fluorescence detection. Repeatability relative standard deviations, RSDr, ranged from 3.2 to 10.0%; reproducibility relative standard deviations, RSDR, ranged from 6.1 to 16.1%. The method has been adopted Official First Action status by AOAC INTERNATIONAL.  相似文献   

8.
A method for determination of lead, cadmium, zinc, copper, and iron in foods by atomic absorption spectrometry (AAS) after dry ashing at 450 degrees C was collaboratively studied in 16 laboratories. The study was preceded by a practice round of familiarization samples and another round in which solutions were distributed and the metals were determined directly by AAS. The study included 5 different foods (liver paste, apple sauce, minced fish, wheat bran, and milk powder) and 2 simulated diets. A single analysis was carried out with each sample. Suitable sample combinations were used as split-level combinations for determination of the repeatability standard deviation. The reproducibility relative standard deviation for each of the elements ranged from 20 to 50% for lead concentrations of 0.040-0.25 mg/kg, from 12 to 352% for cadmium concentrations of 0.001-0.51 mg/kg, from 4 to 8% for zinc concentrations of 0.7-38 mg/kg, from 7 to 45% for copper concentrations of 0.51-45 mg/kg, and from 11 to 14% for iron concentrations of 4-216 mg/kg.  相似文献   

9.
When mercury is quantified by ICP-MS under routine conditions (external calibration) in reference materials, which require mineralization with nitric acid, the experimental concentrations are almost always unacceptably low in comparison to certified values. Sorption of mercury on the Teflon surfaces of the digestion vessels, changes in the viscosity of the aspirated solutions, in the efficiency of the nebulization, in the aerosol transport, and memory effects cannot be responsible for the low results. The intensity of a mercury signal is strongly dependent on the concentration of nitric acid (and other mineral acids) in the measured solutions. Correct results for mercury in the SRM GBW-90101 (Chinese human hair; 2.16+/-0.21 mg Hg/kg certified) can only be obtained, when the solutions, with which the external calibration curves were established, have exactly the same nitric acid concentration as the aspirated digests (2.03+/-0.01 mg Hg/kg; n = 5), when mercury is determined by the standard addition method (2.10+/-0.01 mg Hg/kg; n = 5), or when the experimental mercury concentration obtained at a nitric acid concentration in the digest, different from the concentration in the external calibration solutions, is corrected mathematically based on a pre-established function [Hg2+] = f [HNO3]. The concentrations found by this mathematically based correction 2.04+/-0.01 mg Hg/kg (n = 5) is in good agreement with the values obtained by acid matched calibration or by the standard addition method. For practical work with large numbers of samples the mathematical correction appears to be the method of choice. For occasional mercury determinations, the standard addition method seems to be the most practicable.  相似文献   

10.
建立了一种微波消解前处理技术的半消解法消解样品,采用原子吸收光谱法和原子荧光光谱法同时测定土壤中主要重金属元素铜、锌、镉、砷、汞的方法,检测土壤标准物质GSS-3、GSS-5、GSS-20,结果显示测定均值在标准差允许范围内,相对标准偏差小于8.5%(n=4),是土壤重金属元素快速检测的可选方法。  相似文献   

11.
对研制的铜单元素溶液标准物质的定值方法进行研究。对原子吸收分光光度法和电感耦合等离子体发射光谱法的准确度和精密度进行比较,确定采用原子吸收分光光度法定值。与一级标准物质比较定值,将质量浓度为1 000μg/mL的铜单元素标准物质稀释得到标准系列,用原子吸收分光光度法分析,绘制标准曲线,用外标法对制备的二级铜单元素溶液标准物质进行定值,定值结果为100.1 mg/L,定值结果的不确定度为1.2 mg/L(k=2)。该定值方法可用于单元素金属标准物质和混合金属标准物质的定值。  相似文献   

12.
ABSTRACT

A study for the quantification method of neonicotinoid pesticides (Neos) in human urine that aims to develop the certified reference material (CRM) in the future was carried out. A modified Quick, Easy, Cheap, Effective, Rugged and Safe (QuEChERS) method based on dispersive solid phase extraction (d-SPE) with isotope dilution mass spectrometry (IDMS) was evaluated for the quantification of five Neos (acetamiprid, dinotefuran, imidacloprid, thiacloprid and thiamethoxam) in human urine control by optimisation of the extraction solvent, and the type and amount of d-SPE material. Two types of human urine controls (sample A and B) containing 5 μg/kg and/or 25 μg/kg of Neos were prepared and employed for this study. The results of spike test using sample A (2 mL) obtained by modified QuEChERS method with acetone extraction (10 mL) and d-SPE using a strong cation exchanger (silica gel modified with benzenesulphonic acid phase, SCX) 500 mg were as follows: 97.8%–103.1% for 5 μg/kg and 97.2%–102.7% for 25 μg/kg (described as percentage by the quantification results of IDMS relative to the spiked amount of pesticides). These results were comparable to those by SPE cartridge method using SCX functionalised hydrophilic styrene divinylbenzene (PCX). The repeatabilities of the analyses, represented as relative standard deviations, were also comparable for spike level 5 μg/kg and 25 μg/kg of Neos: 0.1%–7.2% for modified QuEChERS with IDMS and 0.2%–5.6% for PCX cartridge method. The results of spike test using sample B for a spike level 5 μg/kg were 96.0%–100.6%. These results indicate that modified QuEChERS method with IDMS can be used for the development of certified reference material and has the potential to use for the quantification of Neos in real human urine.  相似文献   

13.
In this work, neutron activation analysis was applied to analyze the geological standard materials: GSP-1 and W-1 from USGS, GB-1 and BB-1 from the University of Bahia, Brazil and a sample of uraniferous rock. Hf was determined by instrumental method and the obtained results was shown with relative standard deviations varying from 1.1 to 14%. In the case of Zr analyses, both instrumental and radiochemical neutron activation analyses were used. The interference of154Eu radioisotope that emits -rays too close to those emitted by95Zr was eliminated by retention of Zr in an anionic exchange resin column. The contribution of uranium fission product was considered in the Zr determination by using an interference factor. Results of Zr were presented with relative standard deviations varying from 2.0 to 25.7%. More precise results were obtained by using radiochemical separation. The concentration obtained for Hf and Zr in reference materials agreed well with respective certified values or information values.  相似文献   

14.
The certification by interlaboratory testing of a candidate reference material (ACSL CRM 3) for the concentration (mass fraction) of the pesticides chlorfluazuron (CFZ) and fluazuron (FZN) is described. The certification process was based on a two-stage nested design described in ISO Guide 35. Analysis of results reported by collaborating laboratories provided an assessment of the homogeneity of the RM. The certified values were chlorfluazuron -1.01 mg/kg and fluazuron -1.02 mg/kg. The upper and lower 95% confidence limits for CFZ and FZN were calculated to be: CFZ upper=1.05 mg/kg, lower=0.97 mg/kg; FZN upper=1.08 mg/kg, lower=0.95 mg/kg. A certificate was prepared according to guidelines set out in ISO Guide 31.  相似文献   

15.
16.
A new calibration solution reference material for the determination of perfluorooctane sulfonate anion (PFOS) and its salts has been issued as a certified reference material (CRM) by the National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology (NMIJ/AIST). The purity amount-of-substance fraction of raw material potassium perfluorooctane sulfonate (K-PFOS) was evaluated based on the results obtained using the freezing point depression method, and the purity mass fraction of the raw material was calculated using the average molar mass of impurities, the molar mass of K-PFOS, and the purity amount-of-substance fraction. The certified concentration of this CRM was obtained by multiplying the dilution ratio of the raw material in a prepared solution (methanol) determined from the gravimetric blending method by the purity of the raw material. The preparation concentration of K-PFOS as a certified value of NMIJ CRM 4220-a was determined to be 9.93?mg?kg?1. In addition, the standard uncertainty of the certified value was evaluated from the purity evaluation as well as from sample inhomogeneity, instability, and preparation variation obtained from LC/MS measurements of different gravimetrically prepared solutions of the NMIJ CRM. Consequently, the expanded uncertainty was estimated to be 0.15?mg?kg?1 with a coverage factor k?=?2 corresponding to the half-width of estimated confidence interval of approximately 95%.  相似文献   

17.
Nine laboratories participated in an interlaboratory method performance (collaborative) study of a method for the determination of sodium in foods by flame atomic absorption spectrometry after wet digestion, using a microwave oven technique. Before the study, the laboratories were able to practice on samples with defined sodium levels (pretrial test). The method was tested on a total of 6 foods (broccoli, carrot, bread, saithe fillet, pork, and cheese) with sodium concentrations of 1480-8260 mg/kg. The materials were presented to the participants in the study as blind duplicates, and the participants were asked to perform single determinations for each sample. The repeatability relative standard deviations (RSDr) for sodium ranged from 1.9 to 6.5%. The reproducibility relative standard deviations (RSDR) ranged from 4.2 to 6.9%. The HorRat values ranged from 0.9 to 1.6.  相似文献   

18.
Nine coppery alloys and five basaltic glasses have been quantitatively evaluated as the reference materials to employ in electron probe X-ray microanalysis. The optimum conditions for measurements were selected considering the dependence of intensity and detection limit on the conditions of the X-ray radiation excitation and analytical signal recording. The homogeneity of basaltic glasses and coppery alloys has been examined. The dependence of electron probe X-ray microanalysis accuracy on the homogeneity of reference materials was studied in the reference materials of coppery alloys.Six data sets comprising the average concentrations, standard deviations, relative standard deviations, confidence interval and the z-score of data quality were calculated for 50 control samples: 10 alloys, 14 glasses, 2 metals, 24 minerals and oxides. The average compositions of every control sample were derived in 8–16 analyses. The measured values were corrected for matrix effects applying the original program. These series of concentrations have been compared with each other and with the certified/recommended values using 2-pair selective Student's t-test.The results gained from both laboratory reference materials and certified glass reference materials show comparable accuracy. The quality of all available results complies with the “applied geochemistry” category of performance (2nd category). The laboratory reference materials give comparable accuracy to certified reference materials and can be used for calibrating microprobe techniques, as well as data quality control. The application of laboratory reference materials in microanalysis of silicate minerals and coppery alloys allows reliable analytical data to be acquired. The applications in mineralogy and metallurgy can be extended successfully to the targets when certified reference materials are not available.  相似文献   

19.
A reference material for the determination of overall migration from a plastic coextrudate into the fatty food simulant olive oil was produced and certified in an interlaboratory study. The analyses were carried out according to the ENV 1186 standard from the European Committee for Standardization (CEN) [1, 2, 3] with exposure of the coextrudate to olive oil for 10 days at 40?°C. After an initial preliminary interlaboratory study eight laboratories participated in the certification round, and two different methods were used to obtain single sided exposure of the plastic to the oil. The certified value was determined as the mean of laboratory mean values. No outliers were found. A reference value of 8.6 mg/dm2± 1.4 mg/dm2 (± half width of the 95% confidence interval) was obtained which is within the range relevant for the regulatory limit (10 mg/ dm2), making this reference material suitable for laboratories measuring according to the EU overall migration limit [4]. The material has been found stable over 45 months.  相似文献   

20.
A reference material for the determination of overall migration from a plastic coextrudate into the fatty food simulant olive oil was produced and certified in an interlaboratory study. The analyses were carried out according to the ENV 1186 standard from the European Committee for Standardization (CEN) [ 1, 2, 3] with exposure of the coextrudate to olive oil for 10 days at 40 degrees C. After an initial preliminary interlaboratory study eight laboratories participated in the certification round, and two different methods were used to obtain single sided exposure of the plastic to the oil. The certified value was determined as the mean of laboratory mean values. No outliers were found. A reference value of 8.6 mg/dm2 +/- 1.4 mg/dm2 (+/- half width of the 95% confidence interval) was obtained which is within the range relevant for the regulatory limit (10 mg/ dm2), making this reference material suitable for laboratories measuring according to the EU overall migration limit [4]. The material has been found stable over 45 months.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号