 共查询到20条相似文献,搜索用时 577 毫秒
1.
A low-flow air-cooled inductively coupled plasma (ICP) design for optical emission spectrometry (OES) with axial plasma viewing is described and an evaluation of its analytical capabilities in trace element determinations is presented. Main advantage is a total argon consumption of 0.6 L min−1 in contrast to 15 L min−1 using conventional ICP sources.The torch was evaluated in trace element determinations and studied in direct comparison with a conventional torch under the same conditions with the same OES system, ultrasonic nebulization (USN) and single-element optimization. A variety of parameters (x-y-position of the torch, rf power, external air cooling, gas flow rates and USN operation parameters) was optimized to achieve limits of detection (LOD) which are competitive to those of a conventional plasma source.Ionic to atomic line intensity ratios for magnesium were studied at different radio frequency (rf) power conditions and different sample carrier gas flows to characterize the robustness of the excitation source. A linear dynamic range of three to five orders of magnitude was determined under compromise conditions in multi-element mode. The accuracy of the system was investigated by the determination of Co, Cr, Mn, Zn in two certified reference materials (CRM): CRM 075c (Copper with added impurities), and CRM 281 (Trace elements in rye grass). With standard addition values of 2.44 ± 0.04 and 3.19 ± 0.21 μg g−1 for Co and Mn in the CRM 075c and 2.32 ± 0.09, 81.8 ± 0.4, 32.2 ± 3.9 for Cr, Mn and Zn, respectively, were determined in the samples and found to be in good agreement with the reported values; recovery rates in the 98-108% range were obtained. No influence on the analysis by the matrix load in the sample was observed.  相似文献   

2.
Continuous flow chemical hydride generation coupled directly to a 40 W, atmospheric pressure, 2.45 GHz microwave microstrip Ar plasma operated inside a capillary channel in a sapphire wafer has been optimized for the emission spectrometric determination of As and Sb. The effect of the NaBH4 concentration, the concentration of HCl, HNO3 and H2SO4 used for sample acidification, the Ar flow rate, the reagent flow rates, the liquid volume in the separator as well as the presence of interfering metals such as Fe, Cu, Ni, Co, Zn, Cd, Mn, Pb and Cr, was investigated in detail. A considerable influence of Fe(III) (enhancement of up to 50 %) for As(V) and of Fe(III), Cu(II) and Cr(III) (suppression of up to 75%) as well as of Cd(II) and Mn(II) (suppression by up to 25%) for Sb(III) was found to occur, which did not change by more than a factor of 2 in the concentration range of 2–20 μg ml− 1. The microstrip plasma tolerated the introduction of 4.2 ml min− 1 of H2 in the Ar working gas, which corresponded to an H2/Ar ratio of 28%. Under these conditions, the excitation temperature as measured with Ar atom lines and the electron number density as determined from the Stark broadening of the Hβ line was of the order of 5500 K and 1.50 · 1014 cm− 3, respectively. Detection limits (3σ) of 18 ng ml− 1 for As and 31 ng ml− 1 for Sb were found and the calibration curves were linear over 2 orders of magnitude. With the procedure developed As and Sb could be determined at the 45 and 6.4 μg ml− 1 level in a galvanic bath solution containing 2.5% of NiSO4. Additionally, As was determined in a coal fly ash reference material (NIST SRM 1633a) with a certified concentration of As of 145 ± 15 μg g− 1 and a value of 144 ± 4 μg g− 1 was found.  相似文献   

3.
A simple and fast method for the determination of As, Ba, Cd, Co, Cu, Fe, Ga, Mn, Mo, Ni, Pb, Rb, Se, Sr, Tl, U, V and Zn in biological samples by inductively coupled plasma mass spectrometry (ICP-MS), after sample solubilization with formic acid and introduction by a microconcentric nebulizer, is proposed. The sample is mixed with formic acid, kept at 90 °C for one hour and then diluted with nitric acid aqueous solution to a 50% v/v formic acid and 1% v/v nitric acid final concentrations. The final sample solution flow rate for introduction into the plasma was 30 μL min−1. The optimized and adopted nebulizer gas flow rate was 0.7 L min−1 and RF power was 800 W. These conditions are very different than those normally used when a conventional nebulizer is employed. Rodhium was used as internal standard. External calibration against aqueous standard solutions, without formic acid, could be used for quantification, except for As, Se and Zn. However, external calibration with 50% formic acid allows the determination of all analytes with high accuracy and it is recommended. The detection limits were between 0.0005 (Tl) and 0.22 mg kg−1 (Fe) and the precision expressed by the relative standard deviations (RSD) were between 0.2% (Sr) and 3.5% (Ga). Accuracy was validated by the analysis of four certified reference biological materials of animal tissues, comparing the results by linear regressions and by the t-test at a 95% confidence level. The recommended procedure avoids plasma instability and carbon deposit on the cones.  相似文献   

4.
Continuous flow (CF) chemical hydride generation (CHG) and electrochemical hydride generation (ECHG) directly coupled to a novel 40 W, atmospheric pressure, 2.45 GHz microwave microstrip Ar plasma exiting a microstrip wafer has been developed for the emission spectrometric determination of As and Sb using a miniaturized optical fiber spectrometer and a CCD-array detector. The experimental conditions for both procedures were optimized with respect to the relative net intensities of the As I 228.8 nm and Sb I 252.8 nm lines and their signal-to-background intensity ratios. Additionally, the susceptibility to interferences from Cd, Co, Cr, Cu, Fe, Ni, Pb and Zn and other hydride-forming elements in the determination of As and Sb using the CHG and ECHG techniques was investigated in detail. Under the optimized conditions, it was found that ECHG is more prone to interferences compared to CHG. The detection limits (3σ) of As (6 ng mL−1) and Sb (7 ng mL−1) obtained for the ECHG-MSP-OES method are about three times lower than in the case of the CHG-MSP-OES method due to a two-fold lower amount of H2 introduced into the MSP in case of the ECHG, resulting in a better plasma stability and reduced background level. The linearity ranges for both calibration curves to a concentration of up to 5 μg mL−1 and a precision between 2% and 7% (2 μg mL−1 and 0.050 μg mL−1 of As and Sb, respectively) were found for both methods. The developed ECHG-MSP-OES method was validated for As through the analysis of a certified coal fly ash standard reference material (NIST SRM 1633a) after sample dissolution. The derived concentration (140 ± 8 μg g−1) was found to agree well with the certified data (145 ± 15 μg g−1). The method was also successfully applied to the analysis of both a galvanic bath sample, which contained Sb and was spiked with As, and a tap water sample spiked with both analytes. Recovery rates of 99-101% and a Sb concentration of 6.6 μg mL−1 in the galvanic bath sample were revealed. The latter value showed a good agreement with the data obtained from ICP-OES analysis, which was also used for validation purpose.  相似文献   

5.
A cross-flow atmospheric plasma jet with distilled water or analyte solution nebulization has been investigated. The plasma gas flows perpendicularly to the RF powered electrode (11.21 MHz) and a grounded electrode was added for plasma stabilization. The working parameters of the plasma generator can be controlled in order to maximize either the plasma power (75 W) or the voltage on the RF powered electrode (plasma power, 40 W). The plasma gas, pure argon (0.4 l min1) or a mixture of argon (0.3–0.4 l min1) and helium (0–0.2 l min1), was also used for liquid nebulization. Optical emission of the plasma, collected in the normal viewing mode, was used for plasma diagnostics and for evaluating its excitation capabilities. The influence of helium content in the mixed-gas plasma on the plasma characteristics and on the emission axial profiles of the plasma gas constituents and of the analytes originate from the wet aerosol was studied. The addition of helium to the argon plasma, generally determines decreases in the emission of the plasma gas constituents (with the exception of molecular nitrogen), in the rotational temperature and in the electron number density and increases in the excitation temperatures and in the emission of easily excitable analytes. Based on the determined electron number densities, it was concluded that in the plasma zone which presents interest from analytical point of view the plasma is not very far from the partial thermodynamic equilibrium. In function of the helium content in the plasma gas and of the axial distance from the powered electrode the excitation temperatures are in the range of 2420–3340 K for argon, 2500–5450 K for oxygen and 900–2610 K for ionic calcium and the electron number densities are in the range of 1.2 1012–1.25 1013 cm3. Some elements with excitation energy lower than 6 eV were excited in the plasma. The plasma excitation capability depends on the working conditions of the plasma generator (maximum power or maximum voltage on the RF powered electrode) and on the helium content in the mixed-gas plasma. The estimated detection limits for the studied elements (Na, Li, K, Ca, Cu, Ag, Cd, Hg and Zn) are in the range of 7 ng ml1 to 28 μg ml1.  相似文献   

6.
A simple and selective method for the separation and preconcentration of cadmium in water samples based on solidified floating organic drop microextraction (SFODME) was developed. The cadmium ion in aqueous solution was converted to CdI42− and was then extracted with 160 μL of 1-undecanol containing cationic surfactant of methyltrioctylammonium chloride (0.2 mol/L). When the extraction was completed, the sample vial was cooled in an ice bath for 5 min. The solidified extract was transferred into a conical vial where it melted immediately. It was then diluted to 250 μL upon addition of ethanol, and 100 μL of it was analyzed by flow injection flame atomic absorption spectrometry (FI-FAAS).Factors that influence the extraction and ion pair formation, such as pH, concentration of iodide and methyltrioctylammonium chloride, extraction time, sample volume, and ionic strength were optimized. Under the optimized conditions, a preconcentration factor of 640, detection limit of 0.0079 μg/L and good relative standard deviation of ±5.4% at 5 μg/L were obtained. The procedure was applied to tap water, well water, and sea water; and accuracy was assessed through recovery experiment and independent analysis by graphite atomic absorption spectrometry. The accuracy was also evaluated through analyses of certified reference ore.  相似文献   

7.
A flow injection (FI) method was developed using hydraulic high-pressure nebulization as a sample introduction system, coupled to inductively coupled plasma time-of-flight mass spectrometer (ICP-TOFMS) for rapid and simultaneous determination of 19 elements. The operating conditions of the system (analyte flow rate, heating and cooling temperatures of the desolvation module, carrier gas flow rate) for the simultaneous determination of 19 analytes were optimised. The optimum parameters of the sample introduction system were found to be 1.4 ml min−1 and 1.35 l min−1 for the analyte solution and nebulizer flow rates, respectively. A compromised condition for heating and cooling stage temperatures of 170 and −5 °C was chosen. The detection limits were compared to those obtained by using ICP-TOFMS with alternative sample introduction techniques e.g. conventional nebulization, flow injection chemical hydride generation (FI-CHG) and the obtained results were comparable or better than those resulting from alternative sample introduction. Applying the optimised conditions the simultaneous determination of Ag, As, Ba, Cd, Co, Cu, Ga, In, Li, Mn, Mo, Pb, Sb, Se, Sn, Sr, Tl, V and Zn was carried out. Absolute detection limits (3σ) in the range of 2-750 pg and precision between 0.5 and 9.6% from five replicate measurements of 10 ng ml−1 multielemental sample solutions were achieved by using a 200 μl sample loop. The developed method was applied for the analysis of certified reference materials of biological origin (TORT-2 “Lobster Hepatopancrease”, BCR-422 “Cod Muscle” and IAEA MA-B-3/TM “Fish Homogenate”), and the results showed good agreement with the certified values.  相似文献   

8.
Correia PR  Oliveira PV 《Talanta》2005,67(1):46-53
The effectiveness of internal standardization for simultaneous atomic absorption spectrometry (SIMAAS) was investigated for As and Se determination in urine. Co and Sn were selected as internal standard (IS) candidates based on the evaluation of some physico-chemical parameters related to the atomization. Correlation graphs, plotted from the normalized absorbance signals (n = 20) of internal standard (axis y) versus analyte (axis x), precision, and accuracy of the analytical results were the supportive parameters to choose Co as the most appropriate IS. The urine samples were diluted 1 + 2 to 1.0% (v/v) HNO3 + 80 μg L−1 Co2+. The mixture 20 μg Pd + 3 μg Mg was used as chemical modifier and the optimized temperatures for pyrolysis and atomization steps were 1400 and 2300 °C, respectively. The characteristic masses for As (47 ± 1 pg) and Se (72 ± 2 pg) were estimated from the analytical curves. The detection limits (n = 20, 3δ) were 1.8 ± 0.1 and 2.6 ± 0.1 μg L−1 for As and Se, respectively. The reliability of the entire procedure was checked with the analysis of certified reference material from Sero AS(Seronorm™ Trace Elements in Urine). The obtained results showed the matrix interference disallowed the instrument calibration with aqueous standards. The best analytical condition was achieved when matrix-matched standards were used in combination with Co as IS, which improved the recoveries obtained for As. Under this experimental condition, eight urine samples were analysed and spiked with 10 and 25 μg L−1 As and Se. The mean recoveries were 96 ± 6% (10 μg L−1 As), 95 ± 6% (25 μg L−1 As), 101 ± 7% (10 μg L−1 Se), and 97 ± 4% (25 μg L−1 Se).  相似文献   

9.
A systematic study on the high-temperature Torch Integrated Sample Introduction System (TISIS) for use in Inductively Coupled Plasma Mass Spectrometry (ICP-MS) has been performed. The investigation included the optimization of the relevant parameters (chamber temperature, sheathing gas flow rate, nebulizer gas flow rate, sample uptake rate), the evaluation of its performance characteristics (sensitivity, limits of detection, stability, memory effects, use with the dynamic reaction cell) and representative applications to environmental, biological and clinical samples. Under the optimal conditions (T = 150 °C; nebulizer gas flow rate of 0.7 L min−1 along with sheathing gas flow rate of 0.35 L min−1 and a sample uptake rate of 20 μL min−1), the sensitivity was from 2 to 8 times higher than that measured using a conventional micronebulizer/mini-spray chamber system, due to the enhanced analyte mass transport toward the plasma and the solvent introduction in the vapour form. In addition, for several elements, TISIS provided lower limits of detection than the conventional system, even when the latter worked at 5-fold higher sample uptake rate. Short-term and long-term precision was better than 5%. Spectroscopic interferences arising from common matrices were efficiently removed by the dynamic reaction cell technique. The application of TISIS/ICP-MS to representative certified reference samples (spinach leaves, marine plankton, bone tissue, human blood) proved the suitability of this system for the accurate analysis of limited-size samples.  相似文献   

10.
Two analytical methods for the determination of cadmium in wheat flour by electrothermal atomic absorption spectrometry without prior sample digestion have been compared: direct solid sampling analysis (SS) and slurry sampling (SlS). Besides the conventional modifier mixture of palladium and magnesium nitrates (10 μg Pd + 3 μg Mg), 0.05% (v/v) Triton X-100 has been added to improve the penetration of the modifier solution into the solid sample, and 0.1% H2O2 in order to promote an in situ digestion for SS. For SlS, 30 μg Pd, 12 μg Mg and 0.05% (v/v) Triton X-100 have been used as the modifier mixture. Under these conditions, and using a pyrolysis temperature of 800 °C, essentially no background absorption was observed with an atomization temperature of 1600 °C. About 2 mg of sample have been typically used for SS, although as much as 3-5 mg could have been introduced. In the case of SlS multiple injections had to be used to achieve the sensitivity required for this determination. Calibration against aqueous standards was feasible for both methods. The characteristic mass obtained with SS was 0.6 pg, and that with SlS was 1.0 pg. The limits of detection were 0.4 and 0.7 ng g−1, the limits of quantification were 1.3 and 2.3 ng g−1 and the relative standard deviation (n = 5) was 6-16% and 9-23% for SS and SlS, respectively. The accuracy was confirmed by the analysis of certified reference materials. The two methods were applied for the determination of cadmium in six wheat flour samples acquired in supermarkets of different Brazilian cities. The cadmium content varied between 8.9 ± 0.5 and 13 ± 2 ng g−1 (n = 5). Direct SS gave results similar to those obtained with SlS using multi-injections; the values of both techniques showed no statistically significant difference at the 95% confidence level. Direct SS was finally adopted as the method of choice, due to its greater simplicity, the faster speed of analysis and the better figures of merit.  相似文献   

11.
In the present paper we report the effect of variable magnetic field in the range of 0.04-0.2 T on the emission of two neutral Lithium lines Li I 670.8 nm and Li I 610.3 nm and one ionic line Li II 548.4 nm in the presence of ambient gas on the laser-blow-off plasma plume. Enhancement in the intensity associated with structures was observed in the temporal profile of neutrals, which is strongly dependent on the magnetic field intensity, distance from the target and background gas pressure. At 6 mm distance and 1.33 Pa argon pressure, apart from overall enhancement in the intensity of both the neutral lines, the results reveal some interesting features, e.g. disappearance of structures and narrowing of the temporal extent of 670.8 nm line at higher magnetic fields. On the other hand, the 610.3 nm line exhibits a significant enhancement in the intensity at the trailing part as the field is increased. At a shorter distance (2 mm) and for relatively higher pressures (133.3 Pa), the effect of field is not much prominent. Interestingly, the ionic spectral line does not exhibit any significant change with both, magnetic field and ambient gas.We explain the results by considering the role of various atomic processes viz. electron impact excitation, recombination and diffusion of ambient gas into plume in collisional and hydrodynamical regimes.  相似文献   

12.
A sensitive and accurate LC/MS method was developed for the monitoring of glucosamine (GLcN) dog plasmatic concentration. In this scope, relatively low plasmatic concentrations of GLcN were expected, ranging from 50 to 1000 ng/mL. Liquid chromatography coupled to simple quadrupole mass spectrometry detection (LC/MS) was selected bringing the selectivity and the sensitivity needed for this application. Additionally, a solid phase extraction (SPE) step was performed to reduce matrix and ion suppression effects. Due to the ionisable character of the compound of interest, a mixed-mode strong cation exchange (Plexa PCX) disposable extraction cartridge (DEC) was selected. The separation was carried out on a Zorbax SB-CN column (5 μm, 4.6 mm i.d. × 250 mm), considering hydrophilic interaction liquid chromatography (HILIC). Indeed, the mobile phase was made of methanol and 5 mM ammonium hydrogen carbonate buffer at pH 7.5 (95/5, v/v). The detection was led at m/z ratios of 180.0 and 417.0, for GLcN and IS, respectively. Reliability of the results was demonstrated through the validation of the method using an approach based on the accuracy profile allowing managing the risk associated to the use of these methods in routine analysis: it is thus guaranteed that each future result will fall in the ±30% acceptance limits with a probability of at least 90%. Successful application of the method to a preliminary pharmacokinetic study illustrated the usefulness of the method for pre-clinical studies.  相似文献   

13.
The use of hydride generation coupled with axial view inductively couple plasma atomic emission spectrometry was presented for the determination of selenium in plant samples. The chemical factors affecting potentially the hydride generation efficiency (hydrochloric acid, sodium borohydride and sodium hydroxide concentrations) were assessed through investigation of chemical interference, accuracy and repeatability. The accuracy of measurements was not affected by elements present in high concentration in the plant matrix (K, Ca, Mg, and P). No interference was also observed with transition metals. Using a real sample (maize) with standard additions, decreases of recoveries were sometimes observed for 0.1% (m/v) NaOH, and attained 13.8% in the most unfavourable case. The final accuracy of the method was verified by using two certified reference materials: CRM 402 (white clover) and CRM 279 (sea lettuce). No statistically significant differences were obtained between the measured concentrations and the certified values. The optimized method was found sensitive (detection limit 0.15 μg l−1), reliable and repeatable (R.S.D. between 1.3% and 4.0%).  相似文献   

14.
Permanent modifiers (V, Ir, Ru, V-Ir, V-Ru, and W-V) thermally coated on to platforms of pyrolytic graphite tubes were employed for the determination of Cd, Pb, and Zn in botanic and biological slurries by electrothermal atomic absorption spectrometry (ETAAS). Conventional Pd + Mg(NO3)2 modifier mixture was also used for the determination of analytes in slurries and digested samples. Optimum masses and mass ratios of permanent modifiers for Cd, Pb, and Zn in slurry sample solutions were investigated. The 280 μg of V, 280 μg of V + 200 μg of Ir, 280 μg of V + 200 μg of Ru or 240 μg of W + 280 μg of V in 0.2% (v/v) Triton X-100 plus 0.5% (v/v) HNO3 mixture was found as efficient as 5 μg of Pd + 3 μg of Mg(NO3)2 modifier mixture for obtaining thermal stabilization, and for obtaining best recoveries. Optimization conditions of analytes, such as pyrolysis and atomization temperature, characteristic masses and detection limits, and atomization and background peak profiles were studied with permanent and 5 μg of Pd + 3 μg of Mg(NO3)2 conventional modifiers and compared with each other. The permanent V-Ir, V-Ru, and W-V modifiers remained stable for approximately 250-300 firings when 20 μl of slurries and digested samples were delivered into the atomizer. In addition, the mixed permanent modifiers increase the tube lifetime by 50-95% when compared with untreated platforms. The characteristic masses and detection limits of analytes (dilution factor of 125 ml g−1) obtained with V-Ir based on integrated absorbance as example for 0.8% (m/v) slurries were 1.0 pg and 3 ng g−1 for Cd, 18 pg and 17 ng g−1 for Pb, and 0.7 pg and 4 ng g−1 for Zn, respectively. The results of analytes obtained by employing V-Ir, V-Ru, and W-V permanent modifier mixtures in botanic and biological certified and standard reference materials were in agreement with the certified values of reference materials.  相似文献   

15.
Platform and wall vaporization for electrothermal vaporization (ETV)-inductively coupled plasma mass spectrometry (ICP-MS) determination of some refractory elements (Ti, V, Cr, Mo, La and Zr) and Pb were comparatively studied with the use of poly (tetrafluoroethylene) (PTFE) as fluorinating reagent. The factors affecting the vaporization behaviors of the target analytes in the platform and tube wall vaporization including vaporization temperature and time, pyrolytic temperature and time were studied in detail, and the flow rates of carrier gas/auxiliary carrier gas, were carefully optimized. Under the optimal conditions, the signal profiles, signal intensity, interferences of coexisting ions and analytical reproducibility for wall and platform vaporization ETV-ICP-MS were compared. It was found that both wall and platform vaporization could give very similar detection limits, but the platform vaporization provided higher signal intensity and better precision for some refractory elements and Pb than the wall vaporization. Especially for La, the signal intensity obtained by platform vaporization was 3 times higher than that obtained by wall vaporization. For platform vaporization ETV-ICP-MS, the limits of detection (LODs) of 0.001 μg L−1 (La) ~ 0.09 μg L− 1 (Ti) with the relative standard deviations (RSDs) of 1.5% (Pb) ~ 15.5% (Zr) were obtained. While for wall vaporization ETV-ICP-MS, LODs of 0.005 μg L− 1 (La) ~ 0.4 μg L− 1 (Pb) with RSDs of 3.2% (Mo) ~ 12.8% (Zr) were obtained. Both platform and tube wall vaporization techniques have been used for slurry sampling fluorination assisted ETV-ICP-MS direct determination of Ti, V, Cr, Mo, La, Zr and Pb in certified reference materials of NIES No. 8 vehicle exhaust particulates and GBW07401 soil, and the analytical results obtained are in good agreement with the certified values.  相似文献   

16.
Helena Hansson 《Talanta》2009,79(3):633-638
The utility of a dynamic hollow-fibre liquid phase microextraction method (optimized using a four-variable experimental design and response surface modelling) for extracting dinitrophenolic compounds from human plasma samples was evaluated. The investigated variables were donor phase salt concentration (10-400 mM), donor phase pH (2-6), acceptor phase pH (7-12), and donor/acceptor phase flow rates (30/7.5 to 70/17.5 μL min−1). Four dinitrophenol pesticides were used as model substances at concentrations of 0.1 μg mL−1 in spiked human plasma samples. Extraction efficiencies ranging from 42 to 77% with RSDs below 9 were achieved with the optimized method. The flow rate and acceptor pH were shown to strongly affect the extraction efficiency for all compounds, while the donor phase pH and salt concentration had minor effects. With a well-defined acceptor phase pH and flow rate the system exhibited high robustness. The limits of quantification for the investigated compounds, using the presented extraction method followed by liquid chromatography/electrospray ionization mass spectrometry in selected ion monitoring mode, ranged from 0.05 to 0.1 μg mL−1 plasma.  相似文献   

17.
A direct, versatile method for the determination of ethyl glucuronide (EtG), a biomarker of ethanol consumption, in urine has been developed using reversed-phase liquid chromatography with pulsed electrochemical detection (PED). EtG and methyl glucuronide (MetG), which serves as an internal standard, are readily separated using a mobile phase consisting of 1% acetic acid/acetonitrile (98/2, v/v). Post-column addition of NaOH allows for the detection of all glucuronides using PED at a gold working electrode. Upon optimization, EtG was found to have a limit of detection of 0.03 μg/mL (7 pmol; 50 μL injection volume) and repeatability at the limit of quantitation of 1.7%R.S.D. (relative standard deviation). Solid-phase extraction (SPE) using an aminopropyl phase was used to remove interferents in urine samples prior to their analysis. Compound recovery following SPE was approximately 50 ± 2%. The forensic utility of this method was further validated by the analysis of 29 post-mortem urine specimens, whose results agreed strongly with certified determinations.  相似文献   

18.
This paper describes the use of dilute nitric acid for the extraction and quantification of arsenic species. A number of extractants (e.g. water, 1.5 M orthophosphoric acid, methanol-water and dilute nitric acid) were tested for the extraction of arsenic from marine biological samples, such as plants that have proved difficult to quantitatively extract. Dilute 2% (v/v) nitric acid was found to give the highest recoveries of arsenic overall and was chosen for further optimisation. The optimal extraction conditions for arsenic were 2% (v/v) HNO3, 6 min−1, 90 °C. Arsenic species were found to be stable under the optimised conditions with the exception of the arsenoriboses which degraded to a product eluting at the same retention time as glycerol arsenoribose. Good agreement was found between the 2% (v/v) HNO3 extraction and the methanol-water extraction for the certified reference material DORM-2 (AB 17.1 and 16.2 μg g−1, respectively, and TETRA 0.27 and 0.25 μg g−1, respectively), which were in close agreement with the certified concentrations of AB 16.4 ± 1.1 μg g−1 and TETRA 0.248 ± 0.054 μg g−1.To preserve the integrity of arsenic species, a sequential extraction technique was developed where the previously methanol-water extracted pellet was further extracted with 2% (v/v) HNO3 under the optimised conditions. Increases in arsenic recoveries between 13% and 36% were found and speciation of this faction revealed that only inorganic and simple methylated species were extracted.  相似文献   

19.
A new technique for the determination of suspended particulate trace metals (P-metals >0.2 μm), such as Co, Ni, Cu, Zn, Cd and Pb, in open ocean seawater has been developed by using microwave digestion coupled with flow injection inductively coupled plasma mass spectrometry (FI-ICP-MS). Suspended particulate matter (SPM) was collected from 500 mL of seawater on a Nuclepore filter (0.2 μm) using a closed filtration system. Both the SPM and filter were completely dissolved by microwave digestion. Reagents for the digestion were evaporated using a clean evaporation system, and the metals were redissolved in 0.8 M HNO3. The solution was diluted with buffer solution to give pH 5.0 and the metals were determined by FI-ICP-MS using a chelating adsorbent of 8-hydroxyquinoline immobilized on fluorinated metal alkoxide glass (MAF-8HQ). The procedure blanks with a filter were found to be 0.048 ± 0.008, 10.3 ± 0.3, 0.27 ± 0.05, 3.3 ± 1.8, 0.02 ± 0.03 and 0.85 ± 0.09 ng L−1 for Co, Ni, Cu, Zn, Cd and Pb, respectively (n = 14). Detection limits defined as 3 times the standard deviation of the blanks were 0.023, 0.90, 0.14, 5.3, 0.078 and 0.28 ng L−1 for Co, Ni, Cu, Zn, Cd and Pb, respectively. Accuracy was evaluated using certified reference materials of chlorella (NES CRM No. 3) and marine sediment (HISS-1). The method was applied to the determination of vertical distributions for P-Co, Ni, Cu, Zn, Cd and Pb in the Western North Pacific.  相似文献   

20.
Rezić I  Zeiner M  Steffan I 《Talanta》2011,83(3):865-871
A simple, robust and reliable analytical procedure for the determination of 28 selected elements, namely Al, As, Ba, Be, Bi, Ca, Cd, Co, Cr, Cu, Fe, K, Hg, Mg, Mn, Mo, Na, Ni, Pb, Sc, Si, Se, Sn, Sm, Sr, Tl, V, and Zn in textile materials by inductively coupled plasma optical emission spectrometry (ICP-OES) after microwave digestion of samples was optimized and validated in this work. The total amount of elements present in textile samples was determined after microwave digestion of materials in 7 mol/L nitric acid within the optimal working program: 5 min at 150 °C (power 250 W), 15 min 180 °C (300 W) and 20 min at the maximum temperature of 200 °C (350 W). For the quality control reasons, which were ascertained by analysis of the certified cotton trace elements reference material IAEA-V9, the ICP-OES method was optimized through several parameters: by comparing Meinhard and Gemcone Low Flow nebulizers efficiency, ranging nebulizer gas flows from 0.6 to 1.0 L/min, ranging sample flows from 0.8 to 1.2 mL/min, testing RF power from 1200 to 1400 W, detecting data acquisition time (read time) from 0 to 527 s, ranging washing (delay) time from 0 to 408 s, as well as by checking the occurring interferences for the optimal line selection. Validation included determination of linearity, selectivity, accuracy, reproducibility, precision and limits of detection calculated for all 28 selected elements of interest. The developed analytical procedure was successfully applied on textile fibers (cotton, flax and hemp) as well as on standard knitted textile sample materials (cotton and wool).  相似文献   