首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
The development of an on-line preconcentration system with cloud point extraction for the determination of manganese is described. The system was used to determine manganese levels in food samples using flame atomic absorption spectrometry (FAAS). All steps of the cloud point extraction procedure were performed on-line, from the mixing of reagents to detection. The manganese ions are complexed in a mixture of the reagent 2-[2′-(6-methyl-benzothiazolylazo)]-4-bromophenol (Me-BTABr) and Triton X-114. The components are retained on a minicolumn and then desorbed with eluent acid to subsequent detection of manganese by FAAS. Under the optimized conditions, the method presented a detection limit of 0.7 μg L− 1 and an enrichment factor of 17 to a volume of 3000 μL. The sampling frequency was 30 h− 1. The accuracy of the method was tested by evaluating the amount of Mn in certified reference materials (apple leaves NIST 1515 and spinach leaves NIST 1570a). The proposed procedure was applied to food samples (shrimp powder, flaxseed flour, wheat flour, soy flour and oat), and the results agreed with those obtained by the determination of Mn in foods by atomic absorption spectrometry with electrothermal atomization (ETAAS).  相似文献   

2.
The possibility to use 4-(2-pyridylazo)resorcinol (PAR) and 1-(2-pyridylazo)-2-naphthol (PAN) for manganese(II) concentrating by the micellar extraction at cloud point (CP) temperature and subsequent atomic absorption spectrometry (AAS) determination was investigated. Under the optimum conditions, preconcentration of 100 ml of water sample in the presence of 1% non-ionic surfactant (NS) OP-7, 1×10−4 M 1-(2-pyridylazo)-2-naphthol permitted the detection 5 μg l−1 manganese. The proposed method has been applied to the AAS determination of manganese in water samples after cloud point extraction.  相似文献   

3.
A cloud point extraction (CPE) method has been developed for the preconcentration of trace aluminum prior to its determination by flame atomic absorption spectrometry (FAAS). The CPE method is based on the complex of Al(III) with Xylidyl Blue (XB) and then entrapped in non-ionic surfactant Triton X-114. The main factors affecting CPE efficiency, such as pH of sample solution, concentration of XB and Triton X-114, equilibration temperature and time, were investigated in detail. An enrichment factor of 50 was obtained for the preconcentration of Al(III) with 50 mL solution. Under the optimal conditions, the detection limit of this method for Al(III) is 1.43 μg L− 1, and the relative standard deviation is 2.7% at determination of 100 μg L− 1 Al(III). The proposed method has been applied for determination of trace amount of aluminum in mineral water samples with satisfactory results. Also, the proposed method was applied to the certified reference materials. The results obtained were in good agreement with certified values.  相似文献   

4.
Dithizone (diphenylthiocarbazone) was used as a complexing agent in cloud point extraction for the first time and applied for selective preconcentration of trace amounts of silver. The analyte in the initial aqueous solution was acidified with sulfuric acid (pH<1) and Triton X-114 was added as a surfactant. After phase separation, based on the cloud point separation of the mixture, the surfactant rich phase was diluted with tetrahydrofuran (THF) and the analyte determined in the enriched solution by flame atomic absorption spectrometry. After optimization of the complexation and extraction conditions, a preconcentration factor of 43 was obtained for only 10 ml of sample. The analytical curve was linear in the range of 3-200 ng ml−1 and the limit of detection was 0.56 ng ml−1. The proposed method was applied to the determination of silver in water samples.  相似文献   

5.
The possibility was investigated by using 1-phenyl-3-methyl-4-benzoyl-5-pyrazolone (PMBP) as the chelating reagent for separation and preconcentration of manganese(II) by cloud point extraction (CPE) and subsequent determination by flame atomic absorption spectrometry (FAAS). The effects of experimental conditions such as pH, concentration of chelating agent and surfactant, equilibration temperature and time on cloud point extraction were studied. Under the optimum conditions, preconcentration of 10 ml of sample solution permitted the detection of 1.45 ng mL(-1) of manganese with an enrichment factor of 20. The proposed method was applied to the determination of trace manganese in water samples with satisfactory results.  相似文献   

6.
The dispersive liquid-liquid microextraction (DLLME) was combined with the flame atomic absorption spectrometry (FAAS) for determination of lead in the water samples. Diethyldithiophosphoric acid (DDTP), carbon tetrachloride and methanol were used as chelating agent, extraction solvent and disperser solvent, respectively. A new FAAS sample introduction system was employed for the microvolume nebulization of the non-flammable chlorinated organic extracts. Injection of 20 μL volumes of the organic extract into an air-acetylene flame provided very sensitive spike-like and reproducible signals.Some effective parameters on the microextraction and the complex formation were selected and optimized. These parameters include extraction and disperser solvent type as well as their volume, extraction time, salt effect, pH and amount of the chelating agent. Under the optimized conditions, the enrichment factor of 450 was obtained from a sample volume of 25.0 mL. The enhancement factor, calculated as the ratio of the slopes of the calibration graphs with and without preconcentration, which was about 1000. The calibration graph was linear in the range of 1-70 μg L−1 with a detection limit of 0.5 μg L−1. The relative standard deviation (R.S.D.) for seven replicate measurements of 5.0 and 50 μg L−1 of lead were 3.8 and 2.0%, respectively. The relative recoveries of lead in tap, well, river and seawater samples at the spiking level of 20 μg L−1 ranged from 93.8 to 106.2%. The characteristics of the proposed method were compared with those of the liquid-liquid extraction (LLE), cloud point extraction (CPE), on-line and off-line solid-phase extraction (SPE) as well as co-precipitation, based on bibliographic data. Operation simplicity, rapidity, low cost, high enrichment factor, good repeatability, and low consumption of the extraction solvent at a microliter level are the main advantages of the proposed method.  相似文献   

7.
Sumaira Khan 《Talanta》2009,80(1):158-220
A separation/preconcentration of aluminum (III) (Al3+) has been developed to overcome the problem of high matrix species, which may interfere with the determination of trace quantity of Al3+ in natural water samples. The separation of Al3+ in water samples was carried out from interfering cations by complexing them with 2-methyle 8-hyroxyquinoline (quinaldine) on activated silica. Whereas the separated trace amounts of Al3+ was preconcentrated by cloud point extraction (CPE), as prior step to its determination by spectrofluorimetry (SPF) and flame atomic absorption spectrometry (FAAS). The Al3+ react with 8-hydroxyquinoline (oxine) and then entrapped in non-ionic surfactant Triton X-114. The main factors affecting CPE efficiency, such as pH of sample solution, concentration of oxine and Triton X-114, equilibration temperature and time period for shaking were investigated in detail. The validity of separation/preconcentration of Al3+ was checked by certified reference material of water (SRM-1643e). After optimization of the complexation and extraction conditions, a preconcentration factor of 20 was obtained for Al3+ in 10 mL of natural water samples. The relative standard deviation for 6 replicates containing 100 μg L−1 of Al3+ was 5.41 and 4.53% for SPF and FAAS, respectively. The proposed method has been applied for determination of trace amount of Al3+ in natural water samples with satisfactory results.  相似文献   

8.
A simplified micelle-mediated extraction methodology for the preconcentration of ultratrace levels of cadmium as a prior step to its determination by cold vapor atomic absorption spectrometry (CV-AAS) has been developed. The methodology is based on the cloud point extraction (CPE) of cadmium at pH 8 by using the non-ionic surfactant polyethyleneglycolmono-p-nonylphenylether (PONPE 7.5) without adding any chelating agent. Cadmium cold vapor was generated from 2 ml of the extracted surfactant-rich phase by means of sodium tetrahydroborate (3%, w/v) as a reducing agent and hydrochloric acid (0.2 mol l−1) as a carrier solution. Several important variables that affect the cloud point extraction and cold vapor cadmium generation efficiency were investigated and optimized. The preconcentration of only 50 ml of solution in the presence of 0.06% (v/v) PONPE 7.5 gives an enhancement factor of 62. The calibration graph using the preconcentration system was linear in the range of 4-100 ng l−1 with a correlation coefficient of 0.9992. Detection limit (3 s) obtained in the optimal conditions was 0.56 ng l−1. The relative standard deviation (R.S.D.) for six replicate determinations at 20 ng l−1 Cd level was 3.2%. The proposed method was successfully applied to the ultratrace determination of cadmium in water samples.  相似文献   

9.
N. Shokoufi 《Talanta》2007,73(4):662-667
A new combination method, employing thermal lens spectrometry (TLS) after cloud point extraction (CPE), has been developed for the preconcentration and determination of rhodium. TLS and CPE methods have good matching conditions for the combination because TLS is a suitable method for the analysis of low volume samples obtained after CPE.Rhodium was complexed with 1-(2-pyridylazo)-2-naphthol (PAN) as a complexing agent in an aqueous medium and concentrated by octylphenoxypolyethoxyethanol (Triton X-114) as a surfactant. After the phase separation at 50 °C based on the cloud point extraction of the mixture, the surfactant-rich phase was dried and the remaining phase was dissolved using 20 μL of carbon tetrachloride. The obtained solution was introduced into a quartz micro cell and the analyte was determined by laser induced-thermal lens spectrometry (LI-TLS). The single laser TLS was used as a sensitive method for the determination of Rhodium-PAN complex in 20 μL of the sample. Under optimum conditions, the analytical curve was linear for the concentration range of 0.5-50 ng mL−1 and the detection limit was 0.06 ng mL−1. The enhancement factor of 450 was achieved for 10 mL samples containing the analyte and relative standard deviations were lower than 5%. The developed method was successfully applied to the extraction and determination of rhodium in water samples.  相似文献   

10.
A sensitive and simple solid-phase preconcentration procedure for enrichment of cadmium prior to analysis by flame atomic absorption spectrometry (FAAS) is described. The method is based on the adsorption of cadmium as CdI42− on naphthalene-methyltrioctylammonium chloride adsorbent, elution by nitric acid and subsequent determination by FAAS. The effect of pH, iodide concentration, sample flow rate, volume of the sample and diverse ions on the recovery of the analyte was investigated and optimum conditions were established. A preconcentration factor of 40 was achieved using the optimum conditions. The calibration graph was linear in the range 1-100 ng ml−1 cadmium in the initial solution. The detection limit based on the 3Sb criterion was 0.6 ng ml−1 and the relative standard deviations (RSD) were 3.9 and 1.05% for 5 and 40 ng ml−1, respectively (n=8). The method was successfully applied to the determination of cadmium added to river, tap and Persian Gulf water samples.  相似文献   

11.
A new approach for a cloud point extraction electrothermal atomic absorption spectrometric method was used for determining bismuth. The aqueous analyte was acidified with sulfuric acid (pH 3.0-3.5). Triton X-114 was added as a surfactant and dithizone was used as a complexing agent.After phase separation at 50 °C based on the cloud point separation of the mixture, the surfactant-rich phase was diluted using tetrahydrofuran (THF). Twenty microliters of the enriched solution and 10 μl of 0.1% (w/v) Pd(NO3)2 as chemical modifier were dispersed into the graphite tube and the analyte determined by electrothermal atomic absorption spectrometry. After optimizing extraction conditions and instrumental parameters, a preconcentration factor of 196 was obtained for a sample of only 10 ml. The detection limit was 0.02 ng ml−1 and the analytical curve was linear for the concentration range of 0.04-0.60 ng ml−1. Relative standard deviations were <5%.The method was successfully applied for the extraction and determination of bismuth in tap water and biological samples (urine and hair).  相似文献   

12.
A cloud point extraction process using mixed micelle of the cationic surfactant CTAB and non-ionic surfactant TritonX-114 to extract uranium(VI) from aqueous solutions was investigated. The method is based on the color reaction of uranium with pyrocatechol violet in the presence of potassium iodide in hexamethylenetetramine buffer media and mixed micelle-mediated extraction of complex. The optimal extraction and reaction conditions (e.g. surfactant concentration, reagent concentration, effect of time) were studied and the analytical characteristics of the method (e.g. limit of detection, linear range, preconcentration, and improvement factors) were obtained. Linearity was obeyed in the range of 0.20-10.00 ng mL−1 of uranium(VI) ion and the detection limit of the method is 0.06 ng mL−1. The interference effect of some anions and cations was also tested. The method was applied to the determination of uranium(VI) in tap water, waste-water and well water samples.  相似文献   

13.
Candir S  Narin I  Soylak M 《Talanta》2008,77(1):289-293
A cloud point extraction (CPE) procedure has been developed for the determination trace amounts of Cr(III), Pb(II), Cu(II), Ni(II), Bi(III), and Cd(II) ions by using flame atomic absorption spectrometry. The proposed cloud point extraction method was based on cloud point extraction of analyte metal ions without ligand using Tween 80 as surfactant. The surfactant-rich phase was dissolved with 1.0 mL 1.0 mol L−1 HNO3 in methanol to decrease the viscosity. The analytical parameters were investigated such as pH, surfactant concentration, incubation temperature, and sample volume, etc. Accuracy of method was checked analysis by reference material and spiked samples. Developed method was applied to several matrices such as water, food and pharmaceutical samples. The detection limits of proposed method were calculated 2.8, 7.2, 0.4, 1.1, 0.8 and 1.7 μg L−1 for Cr(III), Pb(II), Cu(II), Ni(II), Bi(III), and Cd(II), respectively.  相似文献   

14.
The possibility to use monocarboxylic acids and their mixtures with amines for copper concentrating by the way of micellar extraction at cloud point temperature, and later atomic absorption spectrometry (AAS) determination was investigated. Under the optimum conditions, preconcentration of 100 ml of water sample in the presence of 1% non-ionic surfactant OP-10, 0.005 M capric acid and 0.01 M octylamine permitted the detection of 0.01 μg ml−1 copper. The proposed method has been applied to the AAS determination of copper in water samples after cloud point extraction.  相似文献   

15.
Ulusoy Hİ  Akçay M  Gürkan R 《Talanta》2011,85(3):1585-1591
The simple and rapid preconcentration technique using cloud point extraction (CPE) was applied for the determination of As(V) and total inorganic arsenic (As(V) plus As(III)) in water samples by means of FAAS. As(V) has formed an ion-pairing complex with Pyronine B in the presence of cetyl pyridinium chloride (CPC) at pH 8.0 and extracted into the non-ionic surfactant Triton X-114, after centrifugation the surfactant-rich phase was separated and diluted with 1.0 mol L−1 HNO3 in methanol. The proposed method is very versatile and economic because it exclusively used conventional FAAS. After optimization of the CPE conditions, a preconcentration factor of 120, the detection and quantification limits of 1.67 and 5.06 μg L−1 with a correlation coefficient of 0.9978 were obtained from the calibration curve constructed in the range of 5.0-2200 μg L−1. The relative standard deviation, RSD as a measure of precision was less than 4.1% and the recoveries were in the range of 98.2-102.4%, 97.4-101.2% and 97.8-101.1% for As(V), As(III) and total As, respectively. The method was validated by the analysis of standard reference materials, TMDA-53.3 and NIST 1643e and applied to the determination of As(III) and As(V) in some real samples including natural drinking water and tap water samples with satisfactory results. The results obtained (34.70 ± 1.08 μg L−1 and 60.25 ± 1.07 μg L−1) were in good agreement with the certified values (34.20 ± 1.38 μg L−1 and 60.45 ± 1.78 μg L−1).  相似文献   

16.
A cold column trapping-cloud point extraction (CCT-CPE) method coupled to high performance liquid chromatography (HPLC) was developed for preconcentration and determination of curcumin in human urine. A nonionic surfactant, Triton X-100, was used as the extraction medium. In the proposed method, a low surfactant concentration of 0.4% v/v and a short heating time of only 2 min at 70 °C were sufficient for quantitative extraction of the analyte. For the separation of the extraction phase, the resulted cloudy solution was passed through a packed trapping column that was cooled to 0 °C. The temperature of the CCT column was then increased to 25 °C and the surfactant rich phase was desorbed with 400 μL ethanol to be directly injected into HPLC for the analysis. The effects of different variables such as pH, surfactant concentration, cloud point temperature and time were investigated and optimum conditions were established by a central composite design (response surface) method. A limit of detection of 0.066 mg L−1 curcumin and a linear range of 0.22–100 mg L−1 with a determination coefficient of 0.9998 were obtained for the method. The average recovery and relative standard deviation for six replicated analysis were 101.0% and 2.77%, respectively. The CCT-CPE technique was faster than a conventional CPE method requiring a lower concentration of the surfactant and lower temperatures with no need for the centrifugation. The proposed method was successfully applied to the analysis of curcumin in human urine samples.  相似文献   

17.
An on-line preconcentration procedure for the determination of bismuth by flame atomic absorption spectrometry (FAAS) has been described. Lewatit TP-207 chelating resin, including iminodiacetate group, packed in a minicolumn was used as adsorbent material. Bi(III) was sorbed on the chelating resin, from which it could be eluted with 3 mol L−1 HNO3 and then introduced directly to the nebulizer-burner system of FAAS. Best preconcentration conditions were established by testing different resin quantities, acidity of sample, types of eluent, sample and eluent solution volumes, adsorption and elution flow rates, and effect of interfering ions. The detection limit of the method was 2.75 μg L−1 while the relative standard deviation was 3.0% for 0.4 μg mL−1 Bi(III) concentration. The developed method has been applied successfully to the determination of bismuth in pharmaceutical cream, standard reference materials and various natural water samples with satisfactory results.  相似文献   

18.
Filik H  Giray D  Ceylan B  Apak R 《Talanta》2011,85(4):1818-1824
A novel fiber optic spectrophotometric method for nitrite determination in different samples is suggested, based on the reaction of nitrite with Safranin O in acidic medium to form a diazo-safranin, which is subsequently coupled with pyrogallol in alkaline medium to form a highly stable, red azo dye, followed by cloud point extraction (CPE) using a mixed micelle of a nonionic surfactant, Triton X-114, with an anionic surfactant, sodium dodecyl sulphate (SDS). The reaction and extraction conditions (e.g., acidity for diazotization and alkalinity for pyrogallol coupling, and other reagent concentrations, time, and tolerance to other ions) were optimized. Linearity was obeyed in a concentration range up to 230 μg L−1, and the detection limit of the method is 0.5 μg L−1 of nitrite ion. The molar absorptivity for nitrite of the Safranin-diazonium salt (?610 nm = 4 × 103 L mol−1 cm−1) existing in literature was greatly enhanced by pyrogallol coupling and CPE enrichment (?592 nm = 1.39 × 105 L mol−1 cm−1). The method was applied to the determination of nitrite in tap water, lake water and milk samples with an optimal preconcentration factor of 20.  相似文献   

19.
Brilliant green was used as a complexing agent in cloud point extraction (CPE) and applied for selective preconcentration of trace amounts of gold in geological matrices. The analyte in the initial aqueous solution was acidified with hydrochloric acid (0.1 M) and octylphenoxypolyethoxyethanol (Triton X-114) was added as a surfactant. After phase separation, based on the cloud point separation of the mixture, the surfactant rich phase was diluted with methanol and the analyte determined in the surfactant rich phase by flame atomic absorption spectrometry (FAAS). After optimization of the complexation and extraction conditions, a preconcentration factor of 31 was obtained for only 10 mL of sample. The analytical curve was linear in the range of 3–1000 ng mL−1 and the limit of detection was 1.5 ng mL−1. The proposed method was applied to the determination of gold in geological samples.  相似文献   

20.
Ibrahim S.I. Adam 《Talanta》2009,77(3):1160-1164
A newly simple flow injection wetting-film extraction system coupled to flame atomic absorption spectrometry (FAAS) has been developed for trace amount of cadmium determination. The sample was mixed on-line with sodium diethyl dithiocarbamate and the produced non-charged Cd(II)-diethyl dithiocarbamate (DDTC) chelate complex was extracted on the thin film of diisobutyl ketone (DIBK) on the inner wall of the PTFE extraction coil. The wetting-film with the extracted analyte was then eluted by a segment of the cover solvent, and transported directly to the FAAS for evaluation. All the important chemical and flow parameters were optimized. Under the optimized conditions an enhancement factor of 35, a sample frequency of 22 h−1 and a detection limit of cL = 0.7 μg l−1 Cd(II) were obtained for 60 s preconcentration time. The calibration curve was linear over the concentration range 1.5-45.0 μg l−1 Cd(II) and the relative standard deviation, R.S.D. (n = 10) was 3.9%, at 10.0 μg l−1 concentration level. The developed method was successfully applied to cadmium determination in a variety of environmental water samples as well as waste-water sample.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号