首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The effect of oxidation of anoxic sediment upon the extraction of 13 elements (Cd, Sn, Sb, Pb, Al, Cr, Mn, Fe, Co, Ni, Cu, Zn, As) using the optimised Community Bureau of Reference of the European Commission (BCR) sequential extraction procedure and a dilute acid partial extraction procedure (4 h, 1 mol L−1 HCl) was investigated. Elements commonly associated with the sulfidic phase, Cd, Cu, Pb, Zn and Fe exhibited the most significant changes under the BCR sequential extraction procedure. Cd, Cu, Zn, and to a lesser extent Pb, were redistributed into the weak acid extractable fraction upon oxidation of the anoxic sediment and Fe was redistributed into the reducible fraction as expected, but an increase was also observed in the residual Fe. For the HCl partial extraction, sediments with moderate acid volatile sulfide (AVS) levels (1-100 μmol g−1) showed no significant difference in element partitioning following oxidation, whilst sediments containing high AVS levels (>100 μmol g−1) were significantly different with elevated concentrations of Cu and Sn noted in the partial extract following oxidation of the sediment. Comparison of the labile metals released using the BCR sequential extraction procedure (ΣSteps 1-3) to labile metals extracted using the dilute HCl partial extraction showed that no method was consistently more aggressive than the other, with the HCl partial extraction extracting more Sn and Sb from the anoxic sediment than the BCR procedure, whilst the BCR procedure extracted more Cr, Co, Cu and As than the HCl extraction.  相似文献   

2.
The variety of extraction procedures used in environmental studies makes it very difficult to compare the results obtained; therefore, harmonisation and standardisation is required. The extraction of heavy metals from soil by un-buffered salt solutions is a method used to estimate soil contamination and trace metal availability to plants. The present study assesses three of these methods. All the three methods are standardised or is undergoing standardisation in Europe: 0.01 mol l−1 CaCl2 (The Netherlands), 0.1 mol l−1 NaNO3 (Switzerland) and 1 mol l−1 NH4NO3 (Germany). The soil-reference material BCR CRM 483, with indicative values for CaCl2, NaNO3, NH4NO3 extractable metals, was analysed for quality control purposes. The three methods were also applied to 10 contaminated soils and the extracted metals (Cd, Cu, Pb, and Zn) were determined. The procedures were found to be precise (typically <10%) for all metals, taking into account the low metal concentrations extracted. The metal extraction efficiency obtained with each procedure was slightly different, and the three methods provided equivalent information while predicting the relative trace-metal mobility (Cd>Zn>Cu>Pb) in the soils studied. From the experience obtained, the 0.01 mol l−1 CaCl2 extraction procedure seems to be the most suitable method for performing a harmonisation process, since this procedure combines an appropriate extraction capacity for this type of studies with the lowest salt concentration in the extracts and, consequently, with a more simple matrix for metal determination.  相似文献   

3.
Here we compared the pHstat test, which examines the leachability of major elements (Ca, Mg, Al, Fe, and Mn), dissolved organic carbon, and trace elements (Cd, Zn, Cu, Pb, and As) in a wide pH range, with single extraction tests based on the use of mild extractants (calcium chloride, acetic acid or EDTA). For this purpose, we examined samples from a variety of environmental conditions (sludges, mineral soils, organic soils, and soils with particulate and/or soluble contamination). Extraction yields obtained with CaCl2 (0.01 mol L−1) and CH3COOH (0.43 mol L−1) correlated well with those from the pHstat at the same pH (r = 0.98 and 0.95, respectively), while the use of EDTA (0.05 mol L−1) led to systematically higher extraction yields than those quantified with the pHstat at the same pH. However, the pHstat test had three distinct advantages: (1) it revealed the relationship between the solubility of the main soil phases and pH; (2) it showed the variation in pollutant leachability due to changes in pH; and (3) it better predicted the maximum contaminant availability. Thus we propose that the pHstat is the best laboratory tests to evaluate the contaminant leachability over a wide range of sample types (soil, sludge, and sediment).  相似文献   

4.
A chelate resin immobilizing carboxymethylated pentaethylenehexamine (CM-PEHA resin) was prepared, and the potential for the separation and preconcentration of trace elements in water samples was evaluated through the adsorption/elution test for 62 elements. The CM-PEHA resin could quantitatively recover various elements, including Ag, Cd, Co, Cu, Fe, Ni, Pb, Ti, U, and Zn, and rare earth elements over a wide pH range, and also Mn at pH above 5 and V and Mo at pH below 7. This resin could also effectively remove major elements, such as alkali and alkaline earth elements, under acidic and neutral conditions. Solid phase extraction using the CM-PEHA resin was applicable to the determination of 10 trace elements, Cd, Co, Cu, Fe, Mn, Mo, Ni, Pb, V, and Zn, in certified reference materials (EnviroMAT EU-L-1 wastewater and ES-L-1 ground water) and treated wastewater and all elements except for Mn in surface seawater using inductively coupled plasma atomic emission spectrometry. The detection limits, defined as 3 times the standard deviation for the procedural blank using 500 mL of purified water (50-fold preconcentration, n = 8), ranged from 0.003 μg L−1 (Mn) to 0.28 μg L−1 (Zn) as the concentration in 500 mL of solution.  相似文献   

5.
This article describes a detailed comparison between the original BCR sequential extraction procedure, step 2 of which involves treatment with 0.1 mol l−1 hydroxylammonium chloride at pH 2, and the revised BCR procedure (step 2: 0.5 mol l−1 hydroxylammonium chloride at pH 1.5). An intermediate protocol was also evaluated in which 0.5 mol l−1 hydroxylammonium chloride at pH 2 was used. The procedures were applied to five soil and sediment substrates: a sewage sludge-amended soil, two different industrially contaminated soils, a river sediment and an inter-tidal sediment. Extractable iron and manganese concentrations were measured to assess the effects of the procedural modifications on dissolution of the reducible matrix components. Trace elements copper, lead and zinc were also determined. Statistical analysis (two-tailed t-tests at 95% confidence interval) indicated that recovery of iron in step 2 was not markedly enhanced when the intermediate protocol was used. However, significantly greater amounts were isolated with the revised BCR scheme than with the original procedure. Copper behaved similarly to iron. Lead recoveries were increased by use of both modified protocols, with the greatest effect occurring for the revised BCR extraction. In contrast, manganese and zinc extraction did not vary markedly between procedures. The work indicates that the revised BCR sequential extraction provides better attack on the iron-based components of the reducible matrix for a wide range of soils and sediments.  相似文献   

6.
D. Point  G. Bareille  C. Belin 《Talanta》2007,72(3):1207-1216
An integrated approach for the accurate determination of total, labile and organically bound dissolved trace metal concentration in the field is presented. Two independent automated platforms consisting of an ultraviolet (UV) on-line unit and a chelation/preconcentration/matrix elimination module were specifically developed to process samples on-site to avoid sample storage prior to inductively coupled plasma mass spectrometry (ICP-MS) analysis. The speciation scheme allowed simultaneous discrimination between labile and organic stable dissolved species of seven trace elements including Cd, Cu, Mn, Ni, Pb, U and Zn, using only 5 ml of sample with detection limits ranging between 0.6 ng l−1 for Cd and 33 ng l−1 for Ni. The influence of UV photolysis on organic matter and its associated metal complexes was investigated by fluorescence spectroscopy and validated against natural samples spiked with humic substances standards. The chelation/preconcentration/matrix elimination procedure was validated against an artificial seawater spiked sample and two certified reference materials (SLRS-4 and CASS-4) to ensure homogenous performance across freshwater, estuarine and seawater samples. The speciation scheme was applied to two natural freshwater and seawater samples collected in the Adour Estuary (Southwestern, France) and processed in the field. The results indicated that the organic complexation levels were high and unchanged for Cu in both samples, whereas different signatures were observed for Cd, Mn, Ni, Pb, U and Zn, suggesting organic ligands of different origin and/or their transformation/alteration along estuarine water mixing.  相似文献   

7.
A method for light and heavy crude oil digestion using microwave-induced combustion (MIC) in closed vessels is described for further determination of Ag, As, Ba, Bi, Ca, Cd, Cr, Fe, K, Mg, Li, Mn, Mo, Ni, Pb, Rb, Se, Sr, Tl, V, and Zn by inductively coupled plasma mass spectrometry (ICP-MS). Conventional microwave-assisted acid digestion (MW-AD) in pressurized vessels and analyte determination by inductively coupled plasma optical emission spectrometry (ICP OES) were also used for results comparison. For MIC procedure, samples were wrapped in polyethylene films and combusted using 20 bar of oxygen and 50 µl of 6 mol l− 1 ammonium nitrate as aid for ignition. The concentration of nitric acid used as absorbing solution was evaluated (1, 2, 4, 7, 10 and 14 mol l− 1) using an additional reflux step after combustion. Accuracy was evaluated for As, Ba, Ni, Se V, and Zn using certified reference material (CRM) with similar matrix composition and for Cr, Fe, K, Mg, Mn, and Mo by neutron activation analysis (NAA). Recovery tests were also performed for all the analytes by MIC and they were better than 97% using 2 mol l− 1 nitric acid as absorbing solution (with reflux step). Agreement with certified values and NAA results was better than 95%. Using MIC it was possible to obtain lower limits of detection (LODs) by ICP-MS and also by ICP OES in comparison with those obtained by MW-AD. In spite of both sample preparation techniques were apparently suitable for crude oil digestion, MIC was preferable in view of the possibility of using diluted nitric acid as absorbing solution that is an important aspect to minimize interferences by ICP-MS and ICP OES. In order to avoid polyatomic interferences on 52Cr and 56Fe determinations by ICP-MS, a dynamic reaction cell with ammonia gas was used. Residual carbon content in digests obtained by MW-AD and MIC was 15% and < 1%, respectively. Using MIC the simultaneous digestion of 8 samples was possible in less than 30 min.  相似文献   

8.
The optimised BCR sequential extraction procedure and a 4 h 1 mol L−1 HCl partial extraction have been performed on the NIST 2711 reference material for a suite of 12 elements (Cd, Sb, Pb, Al, Cr, Mn, Fe, Co, Ni, Cu, Zn, As) using magnetic sector ICP-MS. A pseudo-total aqua regia digest of NIST 2711 has also been undertaken for quality assurance purposes, and comparison of the sum of the four BCR fractions, which included an aqua regia digest on the residue, with the pseudo-total aqua regia digest has been used to assess the accuracy of the BCR partitioning approach. As a result of this work, discrepancies between previous studies about BCR partitioning of elements in NIST 2711 have been discussed and an increase in confidence about the use of BCR partitioning scheme on seven elements (Cd, Pb, Al, Mn, Fe, Cu, Zn) in this standard material has been obtained. On the other hand, BCR partitioning for Sb, Cr, Co, Ni and As has been provided for the first time. Partial extraction results are also reported for the same 12 elements analysed by the optimised BCR procedure, with the partial extraction results exhibiting a strong correlation with the sum of the three labile steps of the BCR procedure.  相似文献   

9.
This paper deals with an often overlooked artifact in sequential and single extraction of metals from soils, viz. the volume to mass (V/m) ratio as a potential source for inadequate extraction yields. We offer a theoretical framework to get a grip on this intricate parameter and came up with a model based on a linear adsorption isotherm to derive the correct maximal metal extractability for a certain extractant. We verified the model experimentally using 0.1 mol l−1 nitric acid for extraction of seven metals (Cr, Co, Cu, Cd, Pb, Ni and Zn) from an urban soil sample, and concluded that commonly used V/m ratios in the range of 10-40 ml g−1 may give as much as 50% too low extraction yields. Thus, a strong caveat is in place as to be very critical what V/m ratios to use and preferably apply the model derived to obtain the correct maximal extractability using a variable V/m ratio method.  相似文献   

10.
A systematic evaluation of different variables affecting the enzymatic hydrolysis of mussel soft tissue by five enzymes, three proteases (pepsin, pancreatin and trypsin), lipase and amylase, has been carried out for the determination of trace elements (As, Al, Cd, Cr, Cu, Fe, Mn, Ni, Pb and Zn) by inductively coupled plasma-atomic emission spectrometry (ICP-AES). Enzymatic hydrolysis methods offers advantages such as a less species alteration, safer laboratory conditions and a less contaminant wastes. The enzymatic hydrolysis was performed in an incubation camera Boxcult with orbital and horizontal shaker. Variables affecting the enzymatic hydrolysis process were simultaneously studied by applying a Plackett-Burman design (PBD). For a confidence interval of 95%, the significant factors for all enzymes and for most of the elements were the pH, the incubation temperature and the ionic strength. These significant factors were optimized later by using a central composite design (CCD), which gave optimum conditions at pH of 1, incubation temperature of 37 °C and ionic strength fixed by sodium chloride at 0.2 M when using pepsin. For pancreatin, trypsin, lipase and amylase there were found two different optimum condition sets. The first one involves the use of a 0.5 M phosphate buffer (ionic strength), at a pH of 6 and at an incubation temperature of 37 °C, which allows the quantitative extraction of Al, Cr, Mn, Pb and Zn. The second conditions set employees a 0.1 M phosphate buffer (ionic strength), a pH of 9 and an incubation temperature at 37 °C, and it results adequate to extract As, Cd, Cu, Fe and Ni. Analytical performances, repeatability of the over-all procedure and accuracy, by analyzing DORM-1, DORM-2 and TORT-1 certified reference materials, were finally assessed for each enzyme. Good agreement with certified values has been assessed for most of the elements (As, Cd, Cr, Cu, Mn, Ni, Pb and Zn) when using trypsin, pepsin and/or pancreatin, except for Cd and Pb in DORM-1 and DORM-2 because of the certified contents in such certified reference materials are lower than the limit of detection (0.10 and 0.16 μg g−1 for Cd and Pb, respectively, for the use of trypsin).  相似文献   

11.
A novel method, combining isotope dilution with standard additions, was developed for the analysis of eight elements (Mn, Fe, Co, Ni, Cu, Zn, Cd and Pb) in seawater. The method requires just 12 mL of sample and employs an off-line pre-concentration step using the commercially available chelating resin Toyopearl AF-Chelate-650M prior to determination by high resolution inductively coupled plasma magnetic sector mass spectrometry (ICP-MS). Acidified samples were spiked with a multi-element standard of six isotopes (57Fe, 62Ni, 65Cu, 68Zn, 111Cd and 207Pb) enriched over natural abundance. In addition, standard additions of a mixed Co and Mn standard were performed on sub-sets of the same sample. All samples were irradiated using a low power (119 mW cm−2; 254 nm) UV system, to destroy organic ligands, before pre-concentration and extraction from the seawater matrix. Ammonium acetate was used to raise the pH of the 12 mL sub-samples (off-line) to pH 6.4 ± 0.2 prior to loading onto the chelating resin. The extracted metals were eluted using 1.0 M Q-HNO3 and determined using ICP-MS. The method was verified through the analysis of certified reference material (NASS-5) and the SAFe inter-comparison samples (S1 and D2), the results of which are in good agreement with the certified and reported consensus values. We also present vertical profiles of the eight metals taken from the Bermuda Atlantic Time Series (BATS) station collected during the GEOTRACES inter-comparison cruise in June 2008.  相似文献   

12.
The work presents an investigation on metal availability in sediments during 13 months using the dispersive-energy X-ray fluorescence (EDXRF) and atomic emission spectrometry with induced argon plasma (ICP-OES) techniques and single extraction (0.1 mol l−1 HCl) and Tessie’s sequential speciation methods. The EDXRF technique could yield essentially the same profile as ICP-OES for the seasonal variation of metals in sediments, but in a more practical way. The sequential extraction procedure (SEP) was more efficient in metal dissolution than single extraction. The Pb, Ni, Al, Cr, and Fe elements were less efficiently extracted with single extraction in relation to sequential extraction. For Co both methodologies were equivalent, but for Cu and Mn the extraction was higher with single extraction. Single extraction does not mobilize Pb, Ni, Al, Cr, and Fe adsorbed on oxides and bound to organic matter. However for Cu and Mn, not only extracted these metals from the four fractions, but it also dissolved part of the fifth fraction (residual). Principal Component Analysis discriminated seasonal variations in the content of several metals, mainly Fe, Co, Ni, and Zn. The mobility of metallic ions in the sediments is conditioned to the seasonal flow of organic and inorganic material coming from the river or by the erosion of adjacent soils.  相似文献   

13.

Various sludge samples from different domestic and industrial wastewater treatment plants were analyzed by Flame Atomic Absorption Spectrometry to evaluate their total and available contents of heavy metals (Cu, Cr, Ni, Pb, Zn and Fe). The EDTA and acetic acid single extraction procedures were applied to these samples with the aim to study the leaching behaviour of the metals in the different sludges and also to predict their possible mobility when these wastes are disposed on the environment and landfills. In acidic medium, a higher extraction efficiency was observed for the major part of the elements studied in the industrial sludges, except for Ni and Zn, which were also considerably released from domestic sludges. In contrast, in the presence of the EDTA complexing ligand, a more elevated mobility of metals was found in the domestic sludges and little or no metals were released from the industrial sludges. Moreover, the results of the microwave total digestions were compared, for all metals, with those obtained using a more simplified pseudototal digestion procedure (based on the EPA Method 3051, named microwave assisted acid digestion of sediments, sludges, soils and oils) and a good agreement was found between them, except for Cr and Ni in some particular samples. The between-batch precision (expressed as RSD) of both compared digestion methods was very similar and values lower than 7.7% were obtained in both cases. A certified domestic sludge material (SRM 2781) was employed to validate the two digestion procedures and no significant differences were found between the certified and experimental values for all the elements studied.  相似文献   

14.
Highly polluted forest/tilled soils and stream sediments from a mining and smelting area were subjected to single-extraction procedures to determine the extractable contents of Cd, Cu, Pb, and Zn. The results obtained from four widely used operationally defined single extraction tests were compared: deionised water, 0.01 mol L−1 CaCl2, 1 mol L−1 NH4NO3 and 0.005 mol L−1 DTPA. The analytical data were coupled with measurement of the pH and Eh in extracts, mineralogical investigations and thermodynamic modelling using the PHREEQC-2 code. The changes in the pH of the equilibrated suspensions significantly influenced the metal extractabilities, with higher values in the lower pH regions. Although the DTPA procedure generally extracted the highest amounts of metals, it was found to be unsuitable for highly organic acidic forest soils, where anionic metal-DTPA complexes are assumed to be re-adsorbed on the positively charged surfaces of soil organic matter and oxides. The NH4NO3 extraction was also unsuitable due to the high ionic strength (1 mol L−1), limiting the use of the thermodynamic speciation model and the formation of the Cu(NH3)2+ complex, leading to acidification of the suspension. 0.01 mol L−1 CaCl2 can be proposed as the most appropriate extraction medium, suitable for speciation modelling and analytical determinations using ICP-techniques and having an ionic strength similar to that of the soil solution. The metals are present in free ionic forms or chlorocomplexes in the CaCl2 extracts, preventing their re-adsorption on the positively charged surfaces of soil solids (organic matter, Fe- and Mn-oxides) in acidic and circum-neutral conditions.  相似文献   

15.
A new technique for the determination of suspended particulate trace metals (P-metals >0.2 μm), such as Co, Ni, Cu, Zn, Cd and Pb, in open ocean seawater has been developed by using microwave digestion coupled with flow injection inductively coupled plasma mass spectrometry (FI-ICP-MS). Suspended particulate matter (SPM) was collected from 500 mL of seawater on a Nuclepore filter (0.2 μm) using a closed filtration system. Both the SPM and filter were completely dissolved by microwave digestion. Reagents for the digestion were evaporated using a clean evaporation system, and the metals were redissolved in 0.8 M HNO3. The solution was diluted with buffer solution to give pH 5.0 and the metals were determined by FI-ICP-MS using a chelating adsorbent of 8-hydroxyquinoline immobilized on fluorinated metal alkoxide glass (MAF-8HQ). The procedure blanks with a filter were found to be 0.048 ± 0.008, 10.3 ± 0.3, 0.27 ± 0.05, 3.3 ± 1.8, 0.02 ± 0.03 and 0.85 ± 0.09 ng L−1 for Co, Ni, Cu, Zn, Cd and Pb, respectively (n = 14). Detection limits defined as 3 times the standard deviation of the blanks were 0.023, 0.90, 0.14, 5.3, 0.078 and 0.28 ng L−1 for Co, Ni, Cu, Zn, Cd and Pb, respectively. Accuracy was evaluated using certified reference materials of chlorella (NES CRM No. 3) and marine sediment (HISS-1). The method was applied to the determination of vertical distributions for P-Co, Ni, Cu, Zn, Cd and Pb in the Western North Pacific.  相似文献   

16.
Fractionation of the metals Cd, Cr, Cu, Ni, Pb and Zn in sediments was performed for samples collected from eight locations in the Poxim river estuary of Sergipe State, northeast Brazil, using the 3-stage sequential extraction procedure proposed by the European Community Bureau of Reference (BCR). The extraction method was found to be satisfactory for analysis of certified reference material BCR-701, with recovery values ranging from 85% (Cu) to 117% (Cr). The detection limits obtained were 0.001 to 0.305 µg g− 1. Zn exhibited greatest mobility and bioavailability, indicative of anthropogenic sources, while Cr was mainly found in the residual fraction and could be used as an indicator for the contribution from natural sources. Cd, Cu, Ni and Pb were associated with the oxidizable fraction, and Pb, Cr and Ni with the reducible fraction. Principal component analysis (PCA) clearly separated the metals into three groups: I (Zn); II (Pb); III (Cd, Cu, Cr and Ni). These groupings were mainly due to different distributions of the metals in the various fractions, in sediments from the different locations. Risk assessment code (RAC) analysis indicated that although the metals presented a moderate overall risk to the aquatic environment, nickel showed a low risk (RAC < 10%) at three sites, while zinc presented a high risk (RAC > 30%) at four other sites.  相似文献   

17.
Silica gel-bound amines phase modified with p-dimethylaminobenzaldehyde (p-DMABD) was prepared based on chemical immobilization technique. The product (SG-p-DMABD) was used as an adsorbent for the solid-phase extraction (SPE) Cr(III), Cu(II), Ni(II), Pb(II) and Zn(II) prior to their determination by inductively coupled plasma optical emission spectrometry (ICP-OES). The uptake behaviors of SG-p-DMABD for extracting these metal ions were studied using batch and column procedures. For the batch method, the optimum pH range for Cr(III) and Ni(II) extraction was ≥ 3, for Cu(II), Pb(II) and Zn(II) extraction it was ≥ 4. For simultaneous enrichment and determination of all the metals on the newly designed adsorbent, the pH value if 4.0 was selected. All the metal ions can be desorbed with 2.0 mL of 0.5 mol L− 1 of HCl. The results indicate that SG-p-DMABD has rapid adsorption kinetics using the batch method. The adsorption capacity for these metal ions is in the range of 0.40-1.15 mmol g− 1, with a high enrichment factor of 125. The presence of commonly coexisting ions does not affect the sorption capacities. The detection limits of the method were found to be 1.10, 0.69, 0.99, 1.10 and 6.50 μg L− 1 for Cr(III), Cu(II), Ni(II), Pb(II) and Zn(II), respectively. The relative standard deviation (RSD) of the method under optimum conditions was 5.0% (n = 8) for all metal ions. The method was applied to the preconcentration of Cr(III), Cu(II), Ni(II), Pb(II) and Zn(II) from the certified reference material (GBW 08301, river sediment) and water samples with satisfactory results.  相似文献   

18.
Marin B  Chopin EI  Jupinet B  Gauthier D 《Talanta》2008,77(1):282-288
The aim of the study was to determine total trace (Cd, Co, Cr, Cu, Mn, Pb and Zn) and major (Al and Fe) element concentrations in calcareous soils using microwave-assisted digestion procedures. The literature showing lack of consensus regarding digestion procedures and unsatisfying recoveries for calcareous materials, four procedures using various acid combinations (HCl, HNO3, H2O2, HF) and volumes were tested using a certified reference material (CRM 141R) and natural calcareous soil samples. Digests were analysed by inductively coupled plasma-atomic emission spectrometry (ICP-AES). Repeatability (R.S.D. <5%) and recoveries (82-116%) showed that the procedures were precise and accurate for most elements. Five calcareous soil samples from a Champagne vineyard plot were, then, subjected to these procedures. In calcareous materials, the presence of HF resulted in Al being severely underestimated (recovery <5%) and Co overestimated (recovery >124%) due to complex formation or spectrochemical interferences, respectively. As digestion was not significantly influenced by the addition of H2O2, the procedure corresponding to Aqua regia (HCl-HNO3) appeared as the best compromise and was selected for further multielemental environmental studies on calcareous materials, even if the absence of HF could lead to incomplete digestion of accessory silicate minerals. Results for a vineyard plot showed that the soils were contaminated (3.65 mg kg−1 Cd, 67 mg kg−1 Cr, 278 mg kg−1 Cu, 143 mg kg−1 Pb and 400 mg kg−1 Zn) as a consequence of urban waste and copper-treatment applications.  相似文献   

19.
In the present work, thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) was employed for Cu and Zn determination in bovine milk and fruit juice samples without any pretreatment. TS-FF-AAS system was optimized and a sample volume of 300 μl was injected into the carrier stream (0.014 mol l−1 HNO3 at a flow rate of 0.4 ml min−1), and it was introduced into a hot Ni tube. The detection limits obtained for Cu and Zn in aqueous solution were 2.2 and 0.91 μg l−1, respectively, and 3.2 μg l−1 for Cu in a medium containing water-soluble tertiary amines. The relative standard deviations varied from 2.7 to 4.2% (n=12). Sample preparation was carried out by simple dilution in water or in water-soluble tertiary amines medium. Accuracy was checked by performing addition-recovery experiments as well as by using reference materials (whole milk powder, non-fat milk powder, and infant formula). Recoveries varied from 97.7 to 105.3% for Cu and Zn. All results obtained for reference materials were in agreement with certified values at a 95% confidence level.  相似文献   

20.
Gopalan Venkatesh 《Talanta》2007,71(1):282-287
Amberlite XAD-16 was loaded with 4-{[(2-hydroxyphenyl)imino]methyl}-1,2-benzenediol (HIMB) via azo linker and the resulting resin AXAD-16-HIMB explored for enrichment of Zn(II), Mn(II), Ni(II), Pb(II), Cd(II), Cu(II), Fe(III) and Co(II) in the pH range 5.0-8.0. The sorption capacity was found between 56 and 415 μmol g−1 and the preconcentration factors from 150 to 300. Tolerance limits for foreign species are reported. The kinetics of sorption is not slow, as t1/2 is ≤15 min. The chelating resin can be reused for seventy cycles of sorption-desorption without any significant change (<2.0%) in the sorption capacity. The limit of detection values (blank + 3 s) are 1.72, 1.30, 2.56, 2.10, 0.44, 2.93, 2.45 and 3.23 μg l−1 for Zn, Mn, Ni, Pb, Cd, Cu, Fe and Co, respectively. The enrichment on AXAD-16-HIMB coupled with flame atomic absorption spectrometry (FAAS) monitoring is used to determine the metal ion ions in river and synthetic water samples, Co in vitamin tablets and Zn in powdered milk samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号