首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A double-bind cross-over study was conducted on four healthy subjects, aged 19-29 years, in order to determine the relative bioavailability and other pharmacokinetics features of fluoride (F) after single oral administration in fasting conditions of 2 mg F as sodium F (NaF) or sodium monofluorophosphate (MFP). The bioavailability was evaluated on the basis of the plasma levels and of the urinary excretion of F. Blood was sampled before and during the 8 h after the administration of the test solutions. For F excretion urine was sampled 12 h before the study and over the 8 h after the administration. Data were tested for statistically significant differences by ANOVA and Tukey's post hoc tests, and also by Student's t-test (p < 0.05). For the two formulations, the pharmacokinetics of F in plasma was characterized by a rapid absorption and by a peak (Cmax = 0.1 μg/mL) which was reached 20 min after administration, followed by a biphasic elimination. In the 8 h following the administration the urinary excretion of F accounted for 35-41% of the administered dose, without significant differences between the two formulations. The AUCs (±S.D.) for NaF and MFP were 21.15 (±0.58) and 19.04 (±1.75) min μg mL−1, respectively, and were not significantly different (p = 0.079). Based on the AUC and Cmax of F in plasma and on the urinary excretion of F during the 8 h following administration, the relative bioavailabilities of the two F formulations were equivalent.  相似文献   

2.
Gendi Jin 《Talanta》2009,80(2):858-1080
A new petentiometric method to determine peroxide hydrogen and glucose had been studied. This method had been applied on the petentiometric determination of peroxide hydrogen and glucose in the total ionic strength adjustment buffer (TISAB) (pH 7.5) solution with the glassy electrode modified by the calix[4]arene. The glassy carbon electrode covered with the calix[4]arene depended on the H2O2 concentration in the range of log[H2O2] from −3.3 to −1.2 in the solution of TISAB (pH 7.5) with nearly Nernstian slope of about 65.6 ± 3 mV and the detection limit of peroxide hydrogen was 4.0 × 10−5 mol L−1. The glassy carbon electrode covered with the calix[4]arene depended on the glucose concentration in the range of log[glucose] from −3.6 to −2.8 in the solution of TISAB (pH 7.5) with nearly Nernstian slope of about 50.2 ± 2 mV and the detection limit of glucose was 2.0 × 10−5 mol L−1. The electrode had the good selectivity, sensitivity, stability and repeatability.  相似文献   

3.
This paper proposes a new automated spectrophotometric method for the simultaneous determination of phosphate and arsenate without pre-treatment, which is faster, simpler, less expensive and hazardous than other well-known methods used with water samples. Such method is based on the different kinetic characteristics of complex formation of phosphate and arsenate with ammonium molybdate. A flow system was used in order to achieve good mixing and to provide precise time control. All the measurements were performed at the isosbestic point wavelength (885 nm). Chemical variables were optimized by factorial design (ammonium molybdate 0.015 mol L−1, potassium antimony tartrate 1 × 10−4 mol L−1, and sulphuric acid 0.7 mol L−1). An appropriate linear range for both analytes (0.50-8.00 μmol L−1), good inter-day reproducibility (4.9% [P] and 3.3% [P + As]) and a sample throughput of 6 h−1 were obtained. The detection limits are 0.4 μmol L−1 P and 0.19 μmol L−1 [P + As] (3.3 Sy/x). The method was validated.  相似文献   

4.
Morales L  Toral MI  Alvarez MJ 《Talanta》2007,74(1):110-118
In this work, a characterization of reagent chromophere 5-(4-sulphophenylazo)-8-aminoquinoline [SPA] by IR and 1H RMN was carried out and a pKa value of 3.55 ± 0.03 was found as well. An 1:2 stoichiometry for the Cu(II)-SPA complex was determined at pH 9 by Job and molar ratio methods. A value of 1.4 × 1014 for the stability constant was also found. Based on the formation of this complex a new method for the copper determination in presence of gold and silver was developed by derivative spectrophotometry using a previous preconcentration on solid phase. In this method, the analytical measures were executed directly in the solid phase containing the complex. The Cu(II) reacts with the reagent chromophere SPA previously retained in the anionic exchange DEAE Sephadex A25. In this determination, the first derivative at 605 nm was used. The quantification range was between (3.2 ± 0.3 × 10−1) × 10−8 and (94.4 ± 0.9) × 10−8 mol L−1 (3.2 ± 0.3 × 10−1) × 10−8 , and (94.4 ± 0.9) × 10−8 mol L−1. The repeatability expressed as RSD was between 1.1 and 2.0%. The method was applied successfully for the copper determination in mineral residuals and natural water samples. The results were consistent with those provided by ICP-mass spectrometry.  相似文献   

5.
A method for determination of nine brominated phenols as environmental risk compounds was developed by on-line coupled capillary isotachophoresis and capillary zone electrophoresis (ITP–CZE). For ITP step, 1 × 10−2 mol L−1 hydrochloric acid with 3 × 10−2 mol L−1 ammediol pH 9.1 was used as the leading electrolyte, and 3 × 10−2 mol L−1 β-alanine with 2 × 10−2 mol L−1 sodium hydroxide pH 10.05 was used as the terminating electrolyte. As the background electrolyte for CZE separation, 2.5 × 10−2 mol L−1 β-alanine with 2.5 × 10−2 mol L−1 lysine pH 9.6 was used. All electrolytes contained 0.05% or 0.1% (m/v) hydroxyethylcellulose to suppress the electroosmotic flow. UV detection at wavelength 220 nm was used. Detection limits in order of tens of nmol L−1 were achieved. Good repeatability of migration times (less than 0.33% RSD) and good repeatability of peak areas (less than 7.19% RSD) at concentration level 5 × 10−8 mol L−1 were observed. Developed ITP–CZE method was applied to determination of brominated phenols in spiked tap and river water samples.  相似文献   

6.
Ayman A. Abdel Aziz 《Talanta》2010,80(3):1356-1363
A highly selective membrane electrodes based on a two newly synthesized nickel (II) Schiff bases, [NiL1] and [NiL2] where L1 and L2 are N,N/bis(salicylaldehyde)4,5-dimethyl-1,2-phenylenediamine (H2L1) and N,N/bis(salicylaldehyde)4,5-dichloro-1,2-phenylenediamine (H2L2) were used as a neutral carrier ionophores for static and hydrodynamic potentiometric mode of operations for the determination of periodate. Under static mode of operation, the sensors displayed a near-Nernstian slope of −66.1 ± 0.8 and −59.9 ± 1.1 mV decade−1 of activity and detection limits to 5.2 × 10−6 and 7.3 × 10−6 mol L−1 for the sensors based on [NiL1] and [NiL2], respectively. Under hydrodynamic mode of operation (FIA), the slope of the calibration plot, limit of detection, and working linear range were −71.1 mVdecade−1 of activity, 7.3 × 10−6 and 1.0 × 10−5 to 1.0 × 10−3 mol L−1, respectively. The response time of the sensors in whole concentration ranges was very short (<10 s). The response of the sensors was independent on the pH range of 3-8. A tubular version was further developed and coupled to a flow injection system for ascorbic acid (AA) determination in beverages and pharmaceutical preparations. This approach was achieved by selecting a 50-cm reactor and an overall flow of 3 mL min−1, and injecting volume 100 μL of AA standards in a 1.0 × 10−4 mol L−1 IO4 solution. Under these conditions, a linearity range of 2-13 μg mL−1, with a slope of 4.97 mV (mg/L)−1 (r2 = 0.9995), detection limit 0.9 mg L−1 and a reproducibility of ±1.1 mV (n = 5) was recorded. This simple and inexpensive flow injection analysis manifold, with a good potentiometric detector, enabled the analysis of ∼50 samples h−1 without requiring pretreatment procedures. An average recovery of 98.8% and a mean standard deviation of 1.3% were obtained.  相似文献   

7.
Dos Santos LB  Abate G  Masini JC 《Talanta》2005,68(2):165-170
Square wave voltammetry automated by sequential injection analysis was applied to determine the Freundlich adsorption coefficients for the adsorption of atrazine onto a clay rich soil. The detection limit in soil extracts was between 0.18 and 0.48 μmol L−1, depending on the medium used to prepare the extracts (0.010 mol L−1 KCl, CaCl2 or HNO3 and 0.0050 mol L−1 H2SO4), all of them conditioned in 40 mmol L−1 Britton-Robinson buffer at pH 2.0 in presence of 0.25 mol L−1 NaNO3. Also in soil extracts the linear dynamic range was between 1.16 and 18.5 μmol L−1 (0.25-4.0 μg mL−1), with a sampling frequency of 190 h−1. The Kf Freundlich adsorption coefficient was 3.8 ± 0.2 μmol1−1/n Ln kg−1 in medium of 0.010 mol L−1 KCl or CaCl2, but increased to 7.7 ± 0.1 and 9.0 ± 0.3 μmol1−1/n Ln kg−1 in 0.010 mol L−1 HNO3 and 0.0050 mol L−1 H2SO4, respectively. The increase of Kf was related to the decrease of pH from 6.4-6.7 in KCl and CaCl2 to 3.7-4.0 in presence of HNO3 or H2SO4, which favors protonation of atrazine, facilitating electrostatic attractions with negative charges of the clay components of the soil. The 1/n parameters were between 0.76 and 0.86, indicating that the isotherms are not linear, suggesting the occurrence of chemisorption at specific adsorption sites. No statistically significant differences were observed in comparison to the adsorption coefficients obtained by HPLC. The advantage of the proposed SI-SWV method is the great saving of reagent because it does not use organic solvent as in the case of HPLC (50% (v/v) acetonitrile in the mobile phase). Additionally the start up of SI-SWV is immediate (no column conditioning necessary) and the analysis time is only 19 s.  相似文献   

8.
Pyrolytic graphite electrodes (PGE) were modified into dopamine solutions using phosphate buffer solutions, pH 10 and 6.5, as supporting electrolyte. The modification process involved a previous anodization of the working electrode at +1.5 V into 0.1 mol L−1 NaOH followed by other anodization step, in the same experimental conditions, into dopamine (DA) solutions. pH of the supporting electrolyte performed an important role in the production of a superficial melanin polymeric film, which permitted the simultaneous detection of ascorbic acid (AA), (DA) and uric acid (UA), ΔEAA-DA = 222 mV; ΔEAA-UA = 360 mV and ΔEDA-UA = 138 mV, avoiding the superficial poisoning effects. The calculated detection limits were: 1.4 × 10−6 mol L−1 for uric acid, 1.3 × 10−5 mol L−1 for ascorbic acid and 1.1 × 10−7 mol L−1 for dopamine, with sensitivities of (7.7 ± 0.5), (0.061 ± 0.001) and (9.5 ± 0.05) A mol−1 cm−2, respectively, with no mutual interference. Uric acid was determined in urine, blood and serum human samples after dilution in phosphate buffer and no additional sample pre-treatment was necessary. The concentration of uric acid in urine was higher than the values found in blood and serum and the recovery tests (92-102%) indicated that no matrix effects were observed.  相似文献   

9.
A novel method of first derivative synchronous fluorescence was developed for the rapid simultaneous analysis of trace 1-hydroxypyrene (1-OHP), 1-naphthol (1-NAP), 2-naphthol (2-NAP), 9-hydroxyphenanthrene (9-OHPe) and 2-hydroxyfluorene (2-OHFlu) in human urine. Only one single scan was needed for quantitative determination of five compounds simultaneously when Δλ = 10 nm was chosen. In the optimal experimental conditions, there was a linear relationship between the fluorescence intensity and the concentration of 1-OHP, 1-NAP, 2-NAP, 9-OHPe and 2-OHFlu in the range of 1.75 × 10−9 to 4.50 × 10−6 mol L−1, 3.64 × 10−8 to 2.20 × 10−4 mol L−1, 8.18 × 10−9 to 1.20 × 10−4 mol L−1, 3.26 × 10−9 to 8.50 × 10−5 mol L−1 and 4.88 × 10−9 to 5.50 × 10−6 mol L−1, respectively. The limits of detection (LOD) were found to be 5.25 × 10−10 mol L−1 for 1-OHP, 1.10 × 10−8 mol L−1 for 1-NAP, 2.46 × 10−9 mol L−1 for 2-NAP, 9.77 × 10−10 mol L−1 for 9-OHPe and 1.46 × 10−9 mol L−1 for 2-OHFlu. The proposed method is reliable, selective and sensitive, and has been used successfully in the determination of traces of 1-OHP, 1-NAP, 2-NAP, 9-OHPe and 2-OHFlu in human urine samples, whose results were in good agreement with those gained by the HPLC method.  相似文献   

10.
Three novel neostigmine bromide (NEO) selective electrodes were investigated with 2-nitrophenyl octyl ether as a plasticiser in a polymeric matrix of polyvinyl chloride (PVC). Sensor 1 was fabricated using tetrakis(4-chlorophenyl)borate (TpClPB) as an anionic exchanger without incorporation of an ionophore. Sensor 2 used 2-hydroxy propyl β-cyclodextrin as an ionophore while sensor 3 was constructed using 4-sulfocalix-8-arene as an ionophore. Linear responses of NEO within the concentration ranges of 10−5 to 10−2, 10−6 to 10−2 and 10−7 to 10−2 mol L−1 were obtained using sensors 1, 2 and 3, respectively. Nernstian slopes of 51.6 ± 0.8, 52.9 ± 0.6 and 58.6 ± 0.4 mV/decade over the pH range of 4-9 were observed. The selectivity coefficients of the developed sensors indicated excellent selectivity for NEO. The utility of 2-hydroxy propyl β-cyclodextrin and 4-sulfocalix[8]arene as ionophores had a significant influence on increasing the membrane sensitivity and selectivity of sensors 2 and 3 compared to sensor 1. The proposed sensors displayed useful analytical characteristics for the determination of NEO in bulk powder, different pharmaceutical formulations, and biological fluids (plasma and cerebrospinal fluid (CSF)) and in the presence of its degradation product (3-hydroxyphenyltrimethyl ammonium bromide) and thus could be used for stability-indicating methods.  相似文献   

11.
The feasibility of using diluted HNO3 solutions under oxygen pressure for decomposition of whole and non-fat milk powders and whey powder samples has been evaluated. Digestion efficiency was evaluated by determining the carbon content in solution (digests) and the determination of Ca, Cd, Cu, Fe, K, Mg, Mn, Mo, Na, Pb and Zn was performed by inductively coupled plasma optical emission spectrometry and Hg by chemical vapor generation coupled to inductively coupled plasma mass spectrometry. Samples (up to 500 mg) were digested using HNO3 solutions (1 to 14 mol L− 1) and the effect of oxygen pressure was evaluated between 2.5 and 20 bar. It was possible to perform the digestion of 500 mg of milk powder using 2 mol L− 1 HNO3 with oxygen pressure ranging from 7.5 to 20 bar with resultant carbon content in digests lower than 1700 mg L− 1. Using optimized conditions, less than 0.86 mL of concentrated nitric acid (14 mol L− 1) was enough to digest 500 mg of sample. The accuracy was evaluated by determination of metal concentrations in certified reference materials, which presented an agreement better than 95% (Student's t test, P < 0.05) for all the analytes.  相似文献   

12.
This work reports a sequential-injection analysis (SIA) method for the enzymatic assay of glucose with soluble glucose oxidase (GOD) and on-line sample dilution with chemiluminescence (CL) detection. A zone of sample was aspirated in the holding coil of the SIA manifold and, if necessary, was diluted on-line by means of an auxiliary dilution conduit. Then, a zone of GOD was aspirated adjacent to the sample zone and a stopped-flow period was applied to allow the enzymatic reaction to proceed with production of hydrogen peroxide. Then, zones of a catalyst (Co(II) solution) and alkaline luminol were aspirated into the holding coil. Finally, the flow was reversed and the stacked zones were sent to a flow-cell located in front of a photomultiplier tube (PMT) that monitored the CL intensity. The linear dynamic range was 1 × 10−5-1 × 10−3 mol L−1 glucose, the coefficient of variation at 8 × 10−5 mol L−1 of glucose was sr = 3.1% (n = 8), the limit of detection at the 3σ level was cL = 1 × 10−6 mol L−1 and the sampling frequency was 28 h−1. With on-line dilution by a factor of 1/200, the linear range could be extended up to 0.2 mol L−1 glucose. The advantages of the proposed method are the simple manifold and instrumentation used, the scope for automated on-line dilution, the low consumption of sample and reagents and the elimination of enzyme immobilisation procedures. The method was applied to the analysis of commercial drinks and honey with percent relative errors in glucose determination in the range 100 ± 6.1%.  相似文献   

13.
Nalidixic acid (NA) and its main metabolite, 7-hydroximethylnalidixic acid (OHNA), are quinolones antibacterial used as agents used for the treatment of urinary tract infection. For both compounds an adsorption process on a hanging mercury electrode (HMDE). On this basis, a square wave adsorptive stripping voltammetry (SWadSV) method has been developed for the individual and simultaneous determination of NA and OHNA. The variables that affect to accumulation process, such as concentration of perchloric acid, accumulation potential and accumulation time have been optimised by using an experimental design (concretely a Box-Behnken design with three levels) together with the response surface methodology (RSM). Calibration curves were linear in the range (0-1.38) × 10−7 mol L−1 for NA and (0-3.23) × 10−8 mol L−1 for OHNA, in the optimized conditions, with detection limits of 9.48 × 10−9 mol L−1 and 8.06 × 10−10 mol L−1 for NA and OHNA, respectively. The method was applied to urine samples containing only one of the analytes with satisfactory recoveries. As the voltammetric signals of these compounds show a high overlapping, different chemometric methods, such as classical least squares (CLS), partial least squares (PLS), principal component regression (PCR) and artificial neural network (ANN) have been used for the resolution of the mixture. The analysis of these compounds in urine samples were carried out using the different chemometric tools and the best recoveries were obtained by using ANN. No pre-treatment of the sample was necessary.  相似文献   

14.
Laser-excited fluorescence was used for the selective determination of camptothecin in samples containing anti-cancer camptothecin-analogs (irinotecan and topotecan). The selectivity of the method was based on the UV photochemical derivatization in basic solution which increased the analyte fluorescence (337/450 nm) and eliminated fluorescence from the two campthotecin-analogs. The influence of UV exposure time and sodium hydroxide concentration was studied using an experimental design. Limit of detection was 4 × 10−10 mol L−1 with linear fluorescence response up to 1 × 10−6 mol L−1. Average recoveries of camptothecin (added to the samples to simulate a contamination) were 92 ± 4 and 94 ± 6% (n = 3) respectively in irinotecan and topotecan based pharmaceuticals.  相似文献   

15.
An adsorptive stripping voltammetric procedure for the determination of U(VI) at an in situ plated lead film electrode is described. The U(VI) complex with cupferron was accumulated from an acetate buffer solution of pH 4.2 at the potential −0.65 V. The measurements were carried out from undeaerated solutions. The calibration graph for an accumulation time of 180 s was linear from 5 × 10−10 to 2 × 10−8 mol L−1. The detection limit was 2 × 10−10 mol L−1, the relative standard deviation for 2 × 10−8 mol L−1 U(VI) was 4.3%. The proposed procedure was validated in the course of U(VI) determination in water certified reference materials.  相似文献   

16.
The influence of the boron-doping levels in boron-doped diamond film electrodes on the electrochemical response of nitrofurantoin (NFT) and the development of an electroanalytical procedure for NFT determination were investigated. The investigations were carried out using the techniques of cyclic voltammetry and square wave voltammetry on diamond film electrodes with different boron-doping levels (i.e., 5000, 10,000 and 20,000 mg L−1). The level of boron-doping in the diamond film electrodes influenced the electrochemical reduction of NFT. The appropriate cyclic voltammetric response of NFT was obtained with Britton-Robinson buffer at pH 4 and for diamond films doped with 10,000 and 20,000 mg L−1 of boron. These two films were selected for the development of the electroanalytical procedure. The use of square wave voltammetry with the optimized parameters demonstrated a good linear relationship between the peak current and the NFT concentration for a wide range of concentration. The lower limit of detection for the electrodes doped with 10,000 and 20,000 mg L−1 of boron were 2.69 × 10−8 mol L−1 (6.40 μg L−1) and 8.15 × 10−9 mol L−1 (1.94 μg L−1), respectively, while the lower limits of quantification were 8.96 × 10−8 mol L−1 (21.33 μg L−1) and 2.72 × 10−8 mol L−1 (6.47 μg L−1), respectively. The applicability of the proposed procedure was tested using a commercial pharmaceutical formulation of NFT, and the results were compared with the procedure recommended by the British Pharmacopeia. The proposed procedure was sensitive, accurate and precise for analysis of NFT and did not require complex preparations or renovations of the electrode surface. This presents the advantage of eliminating mercury waste and minimizing the adsorptive problems related to the use of other electrodic solid surfaces.  相似文献   

17.
A rapid non-separative spectroflourimetric method based on the second-order calibration of the excitation-emission data matrix was proposed for the determination of glutathione (GSH) in human plasma. In the phosphate buffer solution of pH 8.0 GSH reacts with ortho-phthaldehyde (OPA) to yield a fluorescent adduct with maximum fluorescence intensity at about 420 nm. To handle the interfering effects of the OPA adducts with aminothiols other than GSH in plasma as well as intrinsic fluorescence of human plasma, parallel factor (PARAFAC) analysis as an efficient three-way calibration method was employed. In addition, to model the indirect interfering effect of the plasma matrix, PARAFAC was coupled with standard addition method. The two-component PARAFAC modeling of the excitation-emission matrix fluorescence spectra accurately resolved the excitation and emission spectra of GSH, plasma (or plasma constituents). The concentration-related PARAFAC score of GSH represented a linear correlation with the concentration of added GSH, similar to that is obtained in simple standard addition method. Using this standard addition curve, the GSH level in plasma was found to be 6.10 ± 1.37 μmol L−1. The accuracy of the method was investigated by analysis of the plasma samples spiked with 1.0 μmol L−1 of GSH and a recovery of 97.5% was obtained.  相似文献   

18.
A novel long drop time mercury electrode has been constructed from common fused-silica capillary (50 μm I.D., 360 μm E.D.). Proposed device provides reproducible mercury drops with typical lifetime 40-120 s. The electrode was used for a set of electrocapillary measurements aimed at determination of critical micelle concentration of anionic surfactants by a convection controlled drop-time technique. A critical micelle concentration of sodium dodecyl sulfate 5.6 ± 0.4 mmol L−1 and 4.3 ± 0.4 mmol L−1 were obtained in 1 mmol L−1 and 5 mmol L−1 phosphate buffer (pH 7.0), respectively. The values were comparable to those obtained from conductometric measurements under the same conditions (7.0 ± 0.1 mmol L−1 and 5.2 ± 0.1 mmol L−1, respectively) and the difference was explained in accordance with theory of hemi-micelle formation.  相似文献   

19.
Chung KH  Lee W  Cho YH  Choi GS  Lee CW 《Talanta》2005,65(2):389-395
The complexation of europium ion (Eu(III)) with a soil fulvic acid (FA) has been studied at pH 5 in 0.01 M NaClO4 by different experimental methods, i.e. synchronous fluorescence spectroscopy (SyFS) and time resolved laser-induced fluorescence spectroscopy (TRLFS). A series of SyFS quenching spectra was obtained by increasing the Eu(III) concentration and keeping the FA concentration constant. The emission spectra and fluorescence lifetimes of the Eu(III) bound to the FA were also measured by a TRLFS system using the same solution used in the SyFS spectral measurement. From the analysis of the fluorescence data obtained by the SyFS and the TRLFS using a non-linear least-squares method, the concentration of the binding sites (CL) of the FA accessible for the Eu(III) and the corresponding conditional stability constants (log K) were estimated. The two different methods gave rise to constants being comparable with one another. The log K and CL values (mean ± standard deviation of three determinations) determined by the SyFS were 6.4 ± 0.2 (6.7 ± 0.1 μmol L−1: by the TRLFS) and 10 ± 1 μmol L−1 (7 ± 1 μmol L−1: by the TRLFS), respectively. The applicability of the FA fluorescence quenching techniques for estimating the europium binding parameters was proved by the direct monitoring of the Eu(III) bound to the FA using the TRLFS system.  相似文献   

20.
The fabrication and application of a novel electrochemical detection (ED) system with the platinum/poly(methyl violet) (Pt/MV) chemically modified electrode (CME) for high performance liquid chromatography (HPLC) were described. The Pt particles deposited on the poly-MV film were characterized by atomic force microscope (AFM). It was found that the Pt/MV CME exhibited efficiently electrocatalytic effect on the current responses of cysteine (Cys), homocysteine (Hcy) and methionine (Met) with relatively high sensitivity, stability and long-life of activity. In HPLC-ED, these three amino acids had good and stable current responses at the CME and their linear ranges were over three orders of magnitude (R ≥ 0.9996) with the detection limits being 7.5 × 10−8 mol L−1 for Cys, 1.0 × 10−7 mol L−1 for Hcy, 5.0 × 10−7 mol L−1 for Met. The application of this method coupled with microdialysis sampling for the determination of Cys, Hcy and Met in plasma from patients with hypothyroidism was satisfactory.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号