首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Rifampicin can enhance the chemiluminescence (CL) of peroxomonosulfate‐cobalt(II) system, and the CL intensity is strongly dependent on the rifampicin concentrations. Based on this phenomenon, a rapid and sensitive flow injection CL method was developed for the determination of rifampicin. The relative CL intensity was linear with the rifampicin concentration over the range of 5×10?8 to 1×10?6 g·mL?1 (r=0.9991), the detection limit was 7×10?9 g·mL?1 (S/N=3), and the relative standard deviation was 2.7% for 6×10?7 g·mL?1 rifampicin (n=11). Furthermore, this method was successfully applied to the determination of rifampicin in real eye drop and capsules sample.  相似文献   

2.
The supramolecular interaction of gemfibrozil with β-cyclodextrin (β-CD) was studied by spectrofluorimetry. The mechanism of the inclusion was discussed by spectrofluoremetry, infrared spectrum and ^1H NMR spectrum. The results showed that a 1 : 1 (β-CD : gemfibrozil) complex was formed with an apparent association constant of 3.844 × 10^3 L·mol^-1. Based on the enhancement of the fluorescent intensity of gemfibrozil, a spectrofluorimetric method for the determination of gemfibrozil in bulk aqueous solution in the presence of β-CD was developed. The linear range was 3.30 ng·mL^- 1 -6.00 ug·mL^-1 with the detection limit of 0.980 ng·mL^-1. There was no interference from the excipients normally used in tablet composition and the serum main compositions. The proposed method was then successfully applied to the determination of gemfibrozil in capsules and serum.  相似文献   

3.
《Analytical letters》2012,45(5):973-983
Abstract

A rapid and sensitive flow‐injection chemiluminescence (FI‐CL) method, which is based on the CL intensity that generated from the redox reaction of Ce(IV)‐rhodamine B in H2SO4 medium, for the determination of acyclovir and gancyclovir is described. For acyclovir, the determination range is 3×10?8 g mL?1–7×10?5 g mL?1, with 1.56×10?8 g mL?1 as its determination limit. During 11 repeated measurements for 1×10?6 g mL?1 acyclovir, the relative standard deviation was 2.08%. For gancyclovir, the determination range was 5×10?8 g mL?1–7×10?5 g mL?1, with 2.35×10?8 g mL?1 as its determination limit. The relative standard deviation is 2.83% with 11 repeated measurements of 1×10?6 g mL?1 gancyclovir. This method can be successfully used to determine the content of acyclovir and gancyclovir in injections, acyclovir in eye drops, and, maybe, also for other ciclovirs.  相似文献   

4.
《Analytical letters》2012,45(12):1933-1941
Abstract

A rapid and simple flow‐injection chemiluminescence (CL) method is described for the determination of perphenazine, which is based on the CL intensity that generated from the redox reaction of Ce (IV)-perphenazine in HNO3 medium is proportional to the perphenazine concentration without any sensitizers. The proposed method allows the determination range within 1.0×10?7–7.0 ×10?5 g mL?1 with a detection limit of 8.0×10?8 g mL?1, and it has been successfully applied to the determination of the perphenazine in pharmaceutical tablet compared well with the official method.  相似文献   

5.
《Analytical letters》2012,45(6):1033-1045
The amoxicillin-imprinted polymer was synthesized with methacrylic acid (MAA) as a functional monomer and ethylene glycol dimethacrylate (EGDMA) as a cross-linker. The binding characteristic of the imprinted polymer to amoxicillin was evaluated by equilibrium binding experiments. Using the imprinted polymer as recognition material, 3-(3′-nitrophenyl)-5(2′-sulfonylphenylazo)-rhodanine (4NRASP) was synthesized by the authors and was used as chemiluminescence (CL) reagent. A novel chemiluminescence (CL) sensor for the determination of amoxicillin was developed based on the CL reaction of amoxicillin with potassium permanganate in an acidic medium. The sensor displayed excellent selectivity and high sensitivity. The linear response range of the sensor was from 5.0 × 10?9 to 1.0 × 10?6 g · mL?1 (r = 0.9985) and the detection limit was 1.3 × 10?9 g · mL?1. The relative standard deviation for the determination of 1.0 × 10?7 g · mL?1 amoxicillin solution was 1.7% (n = 11). The sensor was applied to the determination of amoxicillin in urine samples with satisfactory results.  相似文献   

6.
A new spectrophotometric method was developed for the determination of aminomethylbenzoic acid (PAMBA) using 7,7,8,8‐tetracyanoquinodimethane (TCNQ). The method was based on the formation of charge transfer (CT) complex of this drug as n‐electron donor with the π‐acceptor TCNQ. TCNQ was found to react with PAMBA to produce a kind of yellow complex. The CT reaction proceeded quantitatively in pH 8.5 buffer solution. Different variables affecting the reaction were carefully studied and optimized. Under optimal reaction conditions, the stoichiometric ratio of the reaction, maximum absorption wavelength and the value of molar absorptivity were measured to be 1:1, 425 nm, and 1.9×104 L·mol?1·cm?1, respectively. Beer′s law was obeyed in the range of 1–9 µg·mL?1 of PAMBA. The data have been filled to a linear regression equation A=?0.2612+0.1123c (µg·mL?1), with a correlation coefficient of 0.9996. The detection limit was 0.4 µg·mL?1, R.S.D. was less than 1.9%, and average recovery was over 97.6%. The formation of the CT complex was also confirmed by both infrared and 1H NMR measurements. The thermodynamic property, kinetic property and reaction mechanism have also been discussed. The method developed was applied successfully to the determination of the subject drug in its pharmaceutical dosage forms with good precision and accuracy compared to official method revealed by t‐ and F‐tests.  相似文献   

7.
在pH为5.0-5.4的乙酸-乙酸钠缓冲溶液中,克林霉素(Clin)与钯(Ⅱ)形成螯合阳离子,它能进一步与二碘荧光素(DIF),赤藓红(Ery),曙红Y(EY)等卤代荧光素类染料反应形成1:1:1的三元离子缔合物,此时将引起吸收光谱变化和荧光猝灭,同时还导致共振瑞利散射(RRS)的急剧增强并产生新的RRS光谱,钯(Ⅱ)-克林霉素与DIF,Ery和EY形成产物的最大散射波长分别位于285,287,32 1nm处,另外还有些较弱的散射峰存在。散射增强(ΔI)与克林霉素浓度在一定范围内成正比,可用于克林霉素的定量测定。对于DIF,Ery和EY体系的线性范围和检出限分别为0.025-2.1μg•mL-1和7.8 ng•mL-1,0.053-2.4μg•mL-1和16.0 ng•mL-1;以及0.038-2.4μg•mL-1和11.0 ng•mL-1。本文研究了适宜的反应条件,考察了共存物质的影响,表明方法有较好的选择性,基于三元离子缔合物的RRS光谱,发展了一种高灵敏、简便快速测定克林霉素的新方法。文中还对离子缔合物的组成,结构和反应机理,以及离子缔合物对吸收,荧光和RRS光谱的影响进行了讨论。  相似文献   

8.
In pH 4.9 Britton-Robinson buffer solution, methotrexate (MTX) reacted with thallium(III) to form a 3∶1 chelate. This resulted in great enhancement of second-order scattering (SOS) spectra and frequency doubling scattering (FDS) spectra and appearance of new SOS and FDS spectra. Their maximum wavelengths were located at 520 and 390 nm, respectively. The increments of scattering intensities (ΔI) were directly proportional to the concentrations of MTX in the ranges of 0.022—2.0 μg•mL-1 (SOS method) and 0.008—2.5 μg•mL-1 (FDS method). The methods exhibited high sensitivities. The detection limits for MTX were 7.4 ng•mL-1 (SOS method) and 2.3 ng•mL-1 (FDS method), respectively. The optimum conditions of the reaction, the influencing factors and the effects of coexisting substances were investigated. A highly sensitive, simple and fast method for the determination of MTX has been developed. The method can be applied satisfactorily to the determination of MTX in human serum samples. In this work, the charge distribution of MTX was calculated by a CNDO quantum chemistry method. In addition, the reaction mechanism was discussed.  相似文献   

9.
《Analytical letters》2012,45(5):746-757
Abstract

Flow injection chemiluminescence (FI-CL) with molecularly imprinted polymer (MIP) was applied to determine fenfluramine. The fenfluramine-imprinted polymer was prepared with acrylamide (AM) as functional monomer and ethylene glycol dimethacrylate (EGDMA) as cross-linker. Methyl and sulfonic group were introduced to rhodanine matrix, and a novel rhodanine ramification 3MORASP was synthesized by the author, and it was used as chemiluminescence reagent. 3-(3′-Methoxyphenyl)-5(2′-sulfonylphenylazo)-rhodanine (3MORASP), first synthesized by the authors, was used as chemiluminescence (CL) reagent. The novel flow path of FI-CL was designed, which made three merged streams of reactants injected into MIP column move through different pathways simultaneously. Fenfluramine was detected based on the reaction of fenfluramine, 3MORASP, and potassium permanganate in an acidic medium. The CL intensity was correlated linearly with the concentration of fenfluramine over the range of 1.0 × 10?7 to 5.0 × 10?6 g · mL?1, and the detection limit was 9.48 × 10?9 g · mL?1. The relative standard deviation (RSD) was 2.4% for determination of 1.0 × 10?6 g · mL?1 fenfluramine (n = 11). This method was successfully applied to the determination of fenfluramine in weight-reducing tonic.  相似文献   

10.
《Analytical letters》2012,45(18):3405-3416
Abstract

A post‐chemiluminescence (PCL) was observed when loperamide hydrochloride solution was injected into the reaction mixture after the finish of CL reaction of alkaline N‐Chlorosuccinimide (NCS) and dichlorofluorescein. Based on this phenomenon, a simple, sensitive and fast flow injection PCL method was established for the determination of loperamide hydrochloride. The possible mechanism for the PCL reaction was discussed via the investigation of the CL kinetic characteristics, the CL spectra, the fluorescence spectra. The PCL intensity responded linearly to the concentration of loperamide hydrochloride in the range 8.0×10?10 to 6.0×10?7 g · ml?1 with a linear correlation of 0.9995. The detection limit was 4×10?10 g · ml?1. The relative standard deviation was 2.4% for 4.0×10?8 g · ml?1 loperamide hydrochloride (n=11). This method has been applied to the determination of loperamide hydrochloride in human plasma and pharmaceutical samples with satisfactory results.  相似文献   

11.
《Analytical letters》2012,45(12):1999-2013
Abstract

A simple, rapid, selective, and sensitive method for the derivative spectrophotometric determination of Hg(II) and its simultaneous determination in the presence of Zn(II) using 2‐(5‐bromo‐2‐pyridylazo)‐5‐diethylaminophenol in the presence of cetylpyridinium chloride, a cationic surfactant, has been developed. The molar absorption coefficient and analytical sensitivity of the 1∶1 Hg(II) complex at 558 nm (λmax) are 5.78×104 L mol?1 cm?1 and 0.67 ng mL?1, respectively. The detection limit of Hg(II) is 1.40×10?2 ng mL?1, and Beer's law is valid in the concentration range 0.05–2.40 µg mL?1. Overlapping spectral profiles of Hg(II) and Zn(II) complexes in zero‐order mode interfere in their simultaneous determination. However, 0.10–2.00 µg mL?1 of Hg(II) and 0.065–0.650 µg mL?1 of Zn(II), when present together, can be simultaneously determined at zero cross point of the derivative spectrum, without any prior separation. The relative standard deviation for six replicate measurements of solutions containing 0.134 µg mL?1 of Hg(II) and 0.620 µg mL?1 of Zn(II) is 1.72 and 1.47%, respectively. The proposed method has successfully been evaluated for trace level simultaneous determination of Hg(II) and Zn(II) in environmental samples.  相似文献   

12.
This work presents a new chemiluminescent (CL) probe array assay. The new type CL probe array is based on enzyme mimics of Co3O4–SiO2 mesoporous nanocomposite material, which not only have an excellent catalytic effect on the luminol–H2O2 CL reaction in an alkaline medium but also can be used for the immobilization of enzymes. The linear range of the lactose concentration is 3.0?×?10?7 to 1.0?×?10?5 g mL?1 and the detection limit is 6.9?×?10?8 g mL?1. β-Galactosidase and glucose oxidase were selected as a model for enzyme assays to demonstrate the applicability of Co3O4–SiO2 mesoporous nanocomposite material in multienzyme immobilization. The novel bifunctional CL probe array has been successfully applied to the determination of lactose in milk.  相似文献   

13.
目的:建立刺激胰岛素分泌的新型降糖药物(-)-2 (S)-苄基-4-酮-4-(顺式-全氢化异吲哚-2-基)丁酸钙对映体的HPLC拆分方法。方法:采用Sumichiral OA-3300手性柱(250 × 4.6 mm I.D., 5 μm), 柱温35℃,以0.05 mol·L-1醋酸铵的甲醇溶液为流动相,检测波长为210 nm。结果:本品两对映体在22分钟内实现良好分离,分离度达3以上,S-异构体分别在0.028 ~ 5.6 μg mL-1和0.03 ~ 6.0 μg mL-1范围内线性关系良好,回归方程分别为:Y=1.32×103x-2.54 (r=0.9997)和Y=1.15×103x-1.78 (r=0.9998),最低检测限分别为0.15 ng和0.10 ng,方法精密度RSD低于1.0% (n=5)。结论:建立的对映体分离方法可用于本品光学异构体的质量控制。  相似文献   

14.
Simple, rapid and reliable method for the determination of albendazole (ABZ) was described. This includes the utility of some Π‐acceptors such as 2,3‐dichloro‐5,6‐dicyano‐p‐benzoquinone (DDQ) and 3,6‐dichloro‐2,5‐dihy‐ droxy‐p‐benzoquinone (p‐CLA) for estimation of ABZ drug (act as donor). The experimental conditions were optimized and the system obeys Beer's law for 7.50–80 and 10.00–85.00 µg·mL?1 of ABZ using DDQ and p‐CLA, respectively. The molar absorptivity and Sandell sensitivity were calculated to be 1.83×103 and 1.12×103 L·mol?1·cm?1, and 2.60 and 3.40 ng·cm?2 using DDQ and p‐CLA, respectively. The limits of detection and quantification were calculated to be (7.42 and 6.73) and (9.94 and 4.13) µg·mL?1 using DDQ and p‐CLA, respectively. The proposed methods were successfully applied to the determination of ABZ in commercially available dosage forms. The reliability of the assays was established by parallel determination by the official method and recovery studies. The chemical structures of the solid charge‐transfer (CT) complexes formed via reaction between ABZ under study and Π‐acceptors, have been elucidated using elemental analyses (C, H and N), IR, 1H NMR and mass spectra.  相似文献   

15.
A method for flow injection with chemiluminescence (CL) detection has been developed for the determination of proteins. It is based on the luminescence of the N-bromosuccinimide-fluorescein-protein system, where fluorescein is used as an energy transfer reagent in alkaline medium. The CL of the system is strongly enhanced by hexadecyl trimethyl ammonium bromide. Optimum conditions and possible mechanisms have been investigated. Under optimum experimental conditions, the linear range is from 0.4 to 40 µg·mL?1 for egg albumin, 0.2 to 20 µg·mL?1 for bovine serum albumin, and from 1 to 100 µg·mL?1 for bovine hemoglobin. The detection limits are 37, 62, and 240 ng·mL?1, respectively.  相似文献   

16.
张四纯  周国俊  鞠熀先 《中国化学》2002,20(10):1049-1054
IntroductionGallicacidexistsintheleavesandfruitsofmanytypesofplantsandiswidelyusedinmedicineforanti oxi dationandantibacterialactivity ,antiflammatoryactionandanti canceractivity .1 5Inspiteofthehealthimportanceofgallicacid ,itsmetabolismandkineticsinthehu…  相似文献   

17.
A simple and novel flow‐injection chemiluminescence (FI‐CL) method was established for the determination of 2‐Methoxyestradiol (2‐ME) in pharmaceutical preparations and biological fluids. The method was based on the significant enhancement of the CL from the KMnO4‐Na2SO3 reaction by 2‐ME in acidic medium. Under optimized conditions, the CL intensity was correlated linearly with concentration of 2‐ME in the range of 5.0 × 10?8‐5.0 × 10?6 M (r = 0.9995). The detection limit (3σ) of 2‐ME was 7.5 × 10?9 M and the relative standard deviation was 0.8% at 5.0 × 10?7 M 2‐ME (n = 8). The proposed method was successfully applied for the flow‐injection CL determination of 2‐ME in pharmaceutical preparations and biological fluids with the recoveries from 92.4 to 106.8%. The possible CL reaction mechanism was also discussed briefly.  相似文献   

18.
A simple and sensitive method was developed for the determination of three nonsteroidal anti-inflammatory drugs (NSAIDs)—ibuprofen, naproxen and fenbufen in human plasma. The method involved in column liquid chromatographic separation and chemilumenescence (CL) detection based on the CL reaction of NSAIDs, potassium permanganate (KMnO4) and sodium sulfite (Na2SO3) in sulfuric acid (H2SO4) medium. The chromatographic separation was carried out using a reversed-phase C18 column, which allowed the selective determination of the three medicines in the complicated samples. The special features of the CL detector provided lower LOD for determination than that of existing chromatographic alternatives. The results indicated that the linear ranges were 0.01–10.0 μg mL?1 for ibuprofen, 0.001–1.0 μg mL?1 for naproxen, and 0.01–10.0 μg mL?1 for fenbufen. The limits of detection were 0.5 ng mL?1 for ibuprofen, 0.05 ng mL?1 for naproxen and 0.5 ng mL?1 for fenbufen (S/N = 3). All average recoveries were in the range of 90.0–102.3%. Finally, the method had been satisfactorily applied for the determination of ibuprofen, naproxen and fenbufen in human plasma samples.  相似文献   

19.
The interaction between anionic surfactants (AS) and 1‐hexadecyl‐3‐methylimidazolium bromide [C16mim]Br was studied by using resonance light scattering (RLS) technique, UV‐Vis spectrophotometry and fluorometric methods. In Britton Robinson (BR) buffer (pH 6.0), [C16mim]Br reacted with AS to form supermolecular complex which resulted in enhancement in RLS intensity. Their maximum RLS wavelengths were all at 390 nm. Some important interacting experimental variables, such as the solution acidity, [C16mim]Br concentration, salt effect and addition order of the reagents, were investigated and optimized. Under the optimum conditions, quantitative determination ranges were 0.001–7 μg·mL?1 for dodecyl sodium sulfate (SDS), 0.001–6 μg·mL?1 for sodium dodecylbenzene sulfonate (SDBS) and 0.005–7 μg·mL?1 for sodium lauryl sulfonate (SLS), respectively, while the detection limits were 1.3 ng·mL?1 for SDS, 1.0 ng·mL?1 for SDBS and 5.1 ng·mL?1 for SLS, respectively. Based on the ion‐association reaction, a highly sensitive, simple and rapid method has been established for the determination of AS.  相似文献   

20.
An extraction-spectrophotometric method for the determination of trace amounts of fluconazole was described. Fluconazole was effectively extracted as a 1 : 1 ion-pair complex with bromocresole green (BCG) at pH 3.0 into chloroform, followed by spectrophotometric determination at 420 nm. Beer's law was obeyed over the range of 4-50 μg.mL^-1 of fluconazole with a detection limit of 3.7 μg.mL^-1 . The method is simple, rapid and sensitive. The procedure was applied to the determination of fluconazole in pharmaceutical preparations as well as its recovery from a blood serum sample.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号