首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A new liquid chromatographic (LC) method for simultaneous determination of lidocaine hydrochloride (LH) and tribenoside (TR) along with their related compounds in pharmaceutical preparations is described. Satisfactory LC separation of all analytes after the liquid–liquid extraction (LLE) procedure with ethanol was performed on a C18 column using a gradient elution of a mixture of acetonitrile and 0.1 % orthophosphoric acid as the mobile phase. The procedure was validated according to the ICH guidelines. The limits of detection (LOD) and quantification (LOQ) were 4.36 and 13.21 μg mL?1 for LH, 7.60 and 23.04 μg mL?1 for TR, and below 0.11 and 0.33 μg mL?1 for their impurities, respectively. Intra- and inter-day precision was below 1.97 %, whereas accuracy for all analytes ranged from 98.17 to 101.94 %. The proposed method was sensitive, robust, and specific allowing reliable simultaneous quantification of all mentioned compounds. Moreover, a comparative study of the RP-LC column classification based on the quantitative structure-retention relationships (QSRR) and column selectivity obtained in real pharmaceutical analysis was innovatively applied using factor analysis (FA). In the column performance test, the analysis of LH and TR in the presence of their impurities was carried out according to the developed method with the use of 12 RP-LC stationary phases previously tested under the QSRR conditions. The obtained results confirmed that the classes of the stationary phases selected in accordance with the QSRR models provided comparable separation for LH, TR, and their impurities. Hence, it was concluded that the proposed QSRR approach could be considered a supportive tool in the selection of the suitable column for the pharmaceutical analysis.  相似文献   

2.
A stability-indicating LC method was developed for the simultaneous determination of ibuprofen and diphenhydramine citrate in pharmaceutical dosage forms. The chromatographic separation was achieved on an Inertsil ODS 3V, 150 × 4.6 mm, 5 μm, column. The mobile phase contained a mixture of 50 mM potassium dihydrogen phosphate buffer:acetonitrile:triethylamine:glacial acetic acid (55:45:0.2:0.2, v/v/v/v). This method allowed the determination of 2.85–9.14 mg mL?1 of ibuprofen and 0.54–1.73 mg mL?1 of diphenhydramine citrate, in a diluent consisting of pH 7.2, 50 mM potassium dihydrogen phosphate buffer:acetonitrile (40:60, v/v). The flow rate was 1.2 mL min?1 and the detection wavelength was 260 nm. The limit of detection for ibuprofen and diphenhydramine citrate was 1.72 and 0.54 μg mL?1 and the limit of quantification was 5.73 and 1.64 μg mL?1, respectively. This method was validated for accuracy, precision and linearity. The method was also found to be stability indicating.  相似文献   

3.
Simple and specific analytical methods for the quantitative determination of sesquiterpenoids from various species of Artemisia plant samples were developed. By LC–UV, LC–ELSD, the separation was achieved by reversed-phase chromatography on a C18 column with water and acetonitrile both containing 0.025% trifluoroacetic acid as the mobile phase. In the LC–MS system, trifluoroacetic acid was replaced by 0.1% formic acid. The wavelength used for quantification of sesquiterpenoids with a diode array detector was 205 nm. The limits of detection by LC–MS was found to be 5, 10, 25, 50, 50 ng mL?1. The limits of detection by LC–UV and LC–ELSD were found to be 5.0, 3.0, 100, 100, 7.5 μg mL?1, by LC–UV and 50, 25, 30, 100 and 75 μg mL?1 by LC–ELSD. LC–mass spectrometry coupled with electrospray ionization (ESI) interface is described for the identification and quantification of sesquiterpenoids in various plant samples. This method involved the use of the [M + H]+ ions of sesquiterpenoids in the positive ion mode with extractive ion monitoring.  相似文献   

4.
Imatinib, bosutinib, dasatinib, pazopanib, erlotinib, canertinib and vatalanib are new developed anticancer drugs, especially for treatment of leukemia. In this article, a fast and high throughput capillary zone electrophoresis method has been developed and validated for analysis of these new drugs in pharmaceutical formulas. The method can be easily utilized for determination of all the drugs in one run what is advantageous for the quality control in pharmaceutical industry because there is no need for changing and optimization of separation conditions when changing the analyte. The separation was performed using an uncoated fused silica capillary with 100 mmol L?1 sodium phosphate buffer pH 2.75, voltage of 25 kV, hydrodynamic injection time of 5 s by 50 mbar, and detection at 214 nm. Under these conditions, the analysis took about 8 min. The validation of all the drugs resulted in recoveries in the range of 84–100 %. The method showed to be precise for all the drugs with RSDs of migration times lower than 0.9 % (interday precision). A very good linearity in the validated range (5–100 μg mL?1) and the limits of detection (LODs) in the range of 0.5–2.0 (μg mL?1) were achieved. Finally, we proved that the method is robust by the Youden’s test. Therefore, our method can be successfully applied for analysis of the real pharmaceutical samples.  相似文献   

5.
A new, simple, rapid, sensitive and specific isocratic RP–LC–UV method was developed and validated for the determination of ondansetron in pharmaceutical dosage forms of orally disintegrating tablets, oral solution and injection. The LC separation was achieved on a Hypersil C4 column (250 × 4.6 mm, 5 μm) using a mobile phase of 50 mM potassium dihydrogen phosphate anhydrous adjusted to pH 3.5 with orthophosphoric acid and acetonitrile (30:70, v/v) at a flow rate of 1.0 mL min?1 and UV detection at 310 nm. The method was validated for specificity, linearity, precision, accuracy, limit of quantification, limit of detection, robustness and solution stability. The calibration curve was linear over a concentration range of 100–1,000 ng mL?1 (r 2  = 0.9996) with limit of detection and limit of quantification 50 and 100 ng mL?1, respectively. The intra-day and inter-day precision and accuracy were between 0.79 and 2.37% and ?0.64 and 1.65%, respectively. The method was successfully applied for analysis of ondansetron in the presence of excipients in commercially available pharmaceutical dosage forms.  相似文献   

6.
7.
A capillary zone electrophoretic method with diode array detection was developed and validated for the determination of rosuvastatin calcium in pharmaceutical formulations. Using fused-silica capillary (i.d. 50.0 μm, total length 48.5 cm and effective length 40.0 cm), the influence of the buffer composition, buffer pH and buffer concentration, as well as organic modifier, applied voltage, capillary temperature and injection time were investigated to optimize the method. Optimum results were obtained with 50.0 mM borate buffer at pH 9.5, capillary temperature 30 °C and applied voltage 25 kV. The samples were injected hydrodynamically for 5 s at 50 mbar. Detection wavelength was set at 243 nm. Diflunisal was used as internal standard. The migration times of rosuvastatin calcium and diflunisal were 3.20 ± 0.01 and 4.20 ± 0.02. The total time of analysis was <6 min. The method was validated for rosuvastatin calcium determination in pharmaceutical formulations through following performance parameters: stability, linearity, sensitivity, precision, accuracy, recovery, selectivity, robustness and ruggedness. The linear calibration range was 3.00–200.00 μg mL?1 and the limits of detection and quantification were 1.00 and 3.00 μg mL?1 with RSD of 4.38 and 3.09%. The proposed method was applied for the determination of rosuvastatin calcium in its pharmaceutical formulation.  相似文献   

8.
Guanidino compounds guanidine, methylguanidine, guanidinoacetic acid, guanidinobutyric acid, guanidinopropionic acid, and guanidinosuccinic acid after derivatization with hexafluoroacetylacetone and ethyl chloroformate at pH 9 in aqueous phase, eluted, and separated from gas chromatographic column HP-5 (30 m × 0.32 mm id) with film thickness of 0.25 μm at an initial column temperature 90 °C for 2 min, followed by heating rate of 10 °C min?1 up to 220 °C with nitrogen flow rate of 1 mL min?1. The detection was by flame ionization detector. The linear calibration ranges of each of guanidino compounds were obtained within 1–10 μg mL?1, and the limit of detection was within 0.014–0.19 μg mL?1. The derivatization and gas chromatography elution and separation were repeatable in terms of retention time and peak height/peak area with relative standard deviation (RSD) (n = 4) within 1.7–2.9 % and 1.4–2.8 %, respectively. The method was applied for the determination of guanidino compounds from deproteinized serum of uremic patients and healthy volunteers, and was found in the range below the limit of quantitation (BLOQ) to 1.25 μg mL?1 with RSD within 1.4–3.6 %, and BLOQ to 0.4 μg mL?1 with RSD 1.3–3.4 %, respectively. A number of pharmaceutical additives did not effect the determination with RSD within ±3.1 %.  相似文献   

9.
A isocratic, selective and accurate LC method of analysis of mexiletine in pharmaceutical preparations has been developed and validated. The method is based on derivatization of mexiletine with 4-chloro-7-nitrobenzofurazan in pH 9.0 borate buffer to yield a yellow product. Chromatography was performed on a C18 column (150 × 4.6 mm i.d.) with acetonitrile–water 80:20 (v/v) as mobile phase at a flow rate of 1.0 mL min?1. UV–visible absorbance detection was performed at 458 nm. The retention time of the mexiletine derivative was 4.10 min, and response was a linear function of concentration in the range 0.5–4.0 μg mL?1 (r = 0.9998). The limits of detection and quantification were 0.05 and 0.15 μg mL?1, respectively. Method validation revealed precision, sensitivity, and robustness were acceptable. Low RSD values are indicative of high precision, and high recovery values are indicative of the accuracy of the method. Results obtained by use of the proposed method for analysis of the mexiletine content of pharmaceutical a preparation were compared with those obtained by use of the official method. The method has been used for analysis of pharmaceutical preparations.  相似文献   

10.
《Analytical letters》2012,45(14):2608-2620
Abstract

A capillary zone electrophoresis (CZE) method has been developed for the determination of the antibiotic sparfloxacin in tablets. The CZE separation was performed using 75 µm×35 cm fused-silica capillary under the following conditions: 25°C; applied voltage, 12 kV; 25 mM H3PO4-NaOH running buffer (pH 8.5). The detection wavelength was 254 nm. Flumequine was used as internal standard (IS). The method was suitably validated with respect to linearity, limit of detection and quantification, accuracy, precision, specificity, and robustness. The calibration was linear from 10 to 60 µg mL?1 and the limit of detection and quantification were 5.38 and 9.46 µg mL?1, respectively. Recoveries ranging from 95.68%–102.4% were obtained in the determination of sparfloxacin that were spiked to placebos. Excipients in the commercial tablets and degraded products from different stress conditions did not interfere in the assay. The method was successfully applied to the determination of sparfloxacin in pharmaceutical tablets.  相似文献   

11.
A simple, sensitive and accurate liquid chromatographic method with UV detection was developed and validated to determine voriconazole in a new emulsion formulation. Chromatographic separation was achieved on a Diamonsil C18 column (250 × 4.6 mm I.D., 5 μm) using a mobile phase consisting of acetonitrile-water-acetic acid (40:60:0.25, v/v/v) at a flow rate of 1.0 mL min?1. The UV detection wavelength was set at 256 nm. The linear calibration curves were obtained in the concentration range of 1.00–100 μg mL?1 with the limit of quantification of 1.00 μg mL?1. The within- and between-run precisions in terms of percentage relative standard deviation were lower than 7.4 and 7.1%, respectively. The accuracy in terms of percentage relative error ranged from ?1.5 to 1.4%. This validated method was successfully applied to the determination of the content of voriconazole in a new emulsion formulation.  相似文献   

12.
A GC-MS method with HP-5MS capillary column was developed for the simultaneous determination of underivatized flunitrazepam, clonazepam, alprazolam, diazepam and ketamine from drinks by extraction with chloroform: isopropanol 1:1 (v/v). All linearity ranges were between 50 and 1,000 μg mL?1 for all compounds both in beer and in peach juice. Limit of detection was between 1.3 and 34.2 μg mL?1, limit of quantification was between 3.9 and 103.8 μg mL?1, the range of recoveries was 73.0 and 112.6% for all drugs in both beverages. The reported method was sensitive, rapid, and suitable for the analysis of the spiked drinks as evidence of sexual assault and robbery phenomena.  相似文献   

13.
Bengi Uslu  Tugba Özden 《Chromatographia》2013,76(21-22):1487-1494
High efficiency and less elution are the basic requirements of high-speed chromatographic separation. In this study, a new gradient reverse phase chromatographic methods were developed using HPLC and UPLC systems for simultaneous determination of enalapril maleate (ENL) and hydrochlorothiazide (HCZ) in pharmaceutical dosage forms. The chromatographic separations of ENL and HCZ were achieved on a Waters μ-Bondapak C 18, (300 × 3.9 mm, 10 μm) and Waters Acquity BEH C18 (100 × 2.1 mm, 1.7 μm) columns for HPLC within 5.30 min and UPLC within a short retention time of 1.95 min, respectively. A linear response was observed over the concentration range 0.270–399 μg mL?1 of ENL, 0.260–399 μg mL?1 of HCZ for HPLC system and 0.270–399 μg mL?1 of ENL and 0.065–249 μg mL?1 of HCZ for UPLC system. Also, limit of detection for ENL was 1.848 ng mL?1 and 31.477 ng mL?1 for HCZ, 2.804 ng mL?1 for ENL and 2.943 ng mL?1 for HCZ using HPLC and UPLC, respectively. The proposed methods were validated according to ICH guideline with respect to precision, accuracy, and linearity. Forced degradation studies were also performed for both compounds in bulk drug samples to demonstrate the specificity and stability indicating power of the HPLC method. Comparison of system performance with conventional HPLC was made with respect to analysis time, efficiency, and resolution.  相似文献   

14.
This article describes the development and validation of a selective high-performance liquid chromatography method that allows, after liquid–liquid extraction and pre-column derivatization reaction with quercetin, the quantification of aluminium chlorohydrate in antiperspirant creams. Chromatographic separation was achieved on an XTerra MS C18 analytical column (150 × 3.0 mm i.d., particle size 5 μm) using a mobile phase of acetonitrile:water (15:85, v/v) containing 0.08 % trifluoroacetic acid at a flow rate of 0.30 mL min?1. Ultraviolet spectrophotometric detection at 415 nm was used. The assay was linear over a concentration range of 3.7–30.6 μg mL?1 for aluminium with a limit of quantitation of 3.74 μg mL?1. Quality control samples (4.4, 17.1 and 30.6 μg mL?1) in five replicates from five different runs of analysis demonstrated intra-assay precision (% coefficient of variation <3.8 %), inter-assay precision (% coefficient of variation <5.4 %) and an overall accuracy (% recovery) between 96 and 101 %. The method was used to quantify aluminium in antiperspirant creams containing 11.0, 13.0 and 16.0 % (w/w) aluminium chlorohydrate, respectively.  相似文献   

15.
A rapid and precise LC method was developed for the simultaneous determination of aliskiren hemifumarate (ALS), amlodipine besylate (AML) and hydrochlorothiazide (HCZ) using acetonitrile:25 mM octane sulfonic acid sodium salt monohydrate in water (60:40 v/v) as the mobile phase. The flow rate was maintained at 1.2 mL min?1 on a stationary phase composed of Supelco, Discovery® HS (C18) column (25 cm × 4.6 mm, 5 μm). Isocratic elution was applied throughout the analysis. Detection was carried out at λ max (232 nm) at ambient temperature. The method was validated according to ICH guidelines. Linearity, accuracy and precision were satisfactory over the concentration ranges of 32–320, 2–44 and 4–64 μg mL?1 for ALS, AML and HCZ, respectively. LOD and LOQ were estimated and found to be 0.855 and 2.951 μg mL?1, respectively, for ALS, 0.061 and 0.202 μg mL?1, respectively, for AML as well as 0.052 and 0.174 μg mL?1, respectively, for HCZ. The method was successfully applied for the determination of the three drugs in their co-formulated tablets. The results were compared statistically with reference methods and no significant difference was found. The developed method is specific and accurate for the quality control and routine analysis of the cited drugs in pharmaceutical preparations.  相似文献   

16.
A simple, sensitive high performance liquid chromatographic method with UV detection was developed and validated for determination of insulin in rat plasma, using methyl paraben as an internal standard. Insulin was extracted from plasma by a liquid–liquid extraction with a mixture of dichloromethane and n-hexane (1:1, v/v) followed by an acidic back extraction. Chromatographic separation was achieved isocratically with a Phenomenex® C18 analytical column (150 × 4.6 mm ID, 5 μm) at ambient room temperature. The calibration curves were linear within a concentration range of 0.7–8.4 μg mL?1 (r 2 = 0.9994). The inter-day and intra-day accuracy and precision were ≤3.33 and ≤5.55%. The limit of detection (LOD) and limit of quantification (LOQ) were 0.35 and 0.7 μg mL?1. The average recovery was 87.86% for insulin and 83.52% for methyl paraben. Insulin containing plasma samples were stable at ?20 °C for 7 days. Validated HPLC method was successfully applied to a pharmacokinetic study of insulin in streptozotocin induced diabetic rats.  相似文献   

17.
A simple, isocratic, stability-indicating liquid chromatographic method for quantitative determination of curcumin was successfully developed. The chromatographic separations were achieved using a Hi-Q-Sil C18; 4.6 mm × 250 mm and 10 μm particle size column employing acetonitrile and acetate buffer (pH 3.0; 60: 40, v/v) as the mobile phase. The analyte was subjected to acidic, basic, oxidative, thermal and photo degradation. The method was validated with respect to linearity, precision, accuracy, limit of detection and limit of quantification. Curcumin was detected by UV-Vis detector at 425 nm whereas the degradation products were detected at 280 nm. The method was linear over the concentration range of 1–10 μg mL?1. The limit of detection was found to be 0.06 μg mL?1 and the quantification limit was 0.21 μg mL?1. Considerable degradation of the analyte was observed when it was subjected to alkaline conditions. Accuracy, evaluated as recovery, was in the range of 97–103%. Intra-day precision and intermediate precision showed relative standard deviations <1% and <2% respectively.  相似文献   

18.
A rapid, sensitive and specific reversed-phase liquid chromatographic method was developed and validated for the quantification of p-hydroxyphenethyl anisate (HPA), which is one of the main constituents of Notopterygium Radix (underground parts of Notopterygium incisum and N. forbesii), in rat plasma, and study its pharmacokinetics after the intravenous administration of 40 mg kg?1 HPA to rats. The method involves a plasma clear-up step using liquid–liquid extraction by ethyl acetate, followed by RP-LC separation and detection. Separation of HPA was performed on an analytical Diamonsil ODS C18 column equipped with a Dikma ODS C18 EasyGuard column using a mobile phase consisting of MeOH–H2O (75:25, v/v) at a flow-rate of 1.0 mL min?1. The UV detection was performed at a wavelength of 256 nm. The linear calibration curves were obtained in the concentration range of 0.05–5.0 μg mL?1 (r = 0.9992, n = 5) in rat plasma with the lower limit of detection of 0.01 μg mL?1 and the lower limit of quantification of 0.04 μg mL?1, and the extraction recovery of HPA was calculated to be the range of 82.01–86.66%. The intra- and inter-day precisions in terms of % relative standard deviation were lower than 2.33 and 3.99% in rat plasma, respectively, with accuracies ranging from 91.22 to 110.5%. The developed method was suitable for the determination and pharmacokinetic study of HPA in rat plasma.  相似文献   

19.
A simple high performance liquid chromatographic assay for the simultaneous quantitative analysis of seven ginsenosides, Rb1, Rb2, Rc, Rd, Re, Rf and Rg1 in commercial ginseng products is described. Chromatographic separation of the analytes was achieved in less than 20 min using a polyvinyl alcohol-bonded column with UV detection at 203 nm. Optimization of chromatographic conditions was determined by a three-factor central composite design, the variables being the percentage of acetonitrile in the mobile phase, column temperature and flow rate. A full quadratic model was found to be adequate in describing the separation of ginsenosides on the polyvinyl alcohol-bonded stationary phase. Complete separation of seven ginsenosides was achieved using acetonitrile–water (82.5/17.5) as the mobile phase run isocratically at a flow rate of 298 μL min?1 and with the column temperature at 9 °C. The developed method was validated over the range of 10–120 μg mL?1 using a 5 μL sample injection volume. Intra- and inter-day variation for three ginsenoside standards (Rf, Rd and Rb1) at three concentration levels ranged from 0.07 to 0.83% expressed as the relative standard deviation. The accuracy based on the nominal concentration values at three concentration levels was in the range 98.7–100.8%. The limit of detection was between 0.43 and 1.03 μg mL?1 while the limit of quantification was from 1.42 to 3.13 μg mL?1. The method is found to be applicable for the determination of ginsenosides in commercial ginseng products.  相似文献   

20.
A simple, rapid, sensitive and reliable liquid chromatographic method for the quantification of BP-1107 in rat plasma has been established. Plasma samples were prepared by extraction with tert-butyl methyl ether, and troglitazone was used as an internal standard. The analytical separation was performed on a C18 column using acetonitrile–0.3% phosphoric acid in water (pH 4.00 adjusted with triethylamine) (75:25, v/v) as a mobile phase. A detailed validation of the method was performed as per USFDA guidelines. For BP-1107 at the concentrations of 2.42, 16.11 and 32.22 μg mL?1 in rat plasma, the extraction recoveries were 114.14 ± 9.75, 95.37 ± 12.06 and 90.00 ± 6.46%, respectively. The mean recovery for internal standard was 91.96 ± 2.51%. The lower limit of quantitation of BP-1107 was 16 ng. The linear quantification range of the method was 0.81–53.70 μg mL?1 in rat plasma with a correlation coefficient greater than 0.999. The intra-day and inter-day accuracy for BP-1107 at 2.42, 16.11 and 32.22 μg mL?1 levels in rat plasma fell between 97.10–110.02 and 97.52–108.04%. The intra-day and inter-day precision were in the ranges of 1.91–5.63 and 4.43–6.28%, respectively. The method was successfully applied to a pharmacokinetic study of BP-1107 in rats after an intravenous administration.  相似文献   