首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A stereoselective high-performance liquid chromatographic method that utilizes fluorescence detection was developed for the selective and sensitive quantification of R(-)- and S(+)-enantiomers of MK-571 (1), a potent and specific leukotriene D4 antagonist, in human plasma. Racemic 1 was isolated from the acidified plasma using solid-phase extraction and the resulting residue was successfully reacted with isobutyl chloroformate and R(+)-1-(1-naphthyl)ethylamine in triethylamine-acetonitrile medium to form the diastereomer of each enantiomer. A structural analogue of 1 was used as internal standard. The derivatized sample was dissolved in 1,1,2-trichlorotrifluoroethane and an aliquot was chromatographed on a (R)-urea chiral column using a mobile phase containing 89% triethylamine-pentane (3:1000, v/v), 10% 2-propanol, and 1% acetonitrile at a flow-rate of 1.5 ml/min. The fluorescence response (excitation wavelength, 350 nm; emission wavelength, 410 nm) was linear (r2 greater than 0.999) for concentrations of enantiomers of 1 from 0.05 micrograms/ml, the lowest quantitation limit, up to 2.5 micrograms/ml. Intra-day coefficients of variation at 0.05 microgram/ml were 2.4% for the R(-)-isomer and 2.0% for S(+)-isomer. The corresponding inter-day coefficients of variation for R(-)- and S(+)-1 were 2.6 and 3.6%, respectively. The utility of the methodology was established by analysis of plasma samples from male volunteers receiving single intravenous and oral doses of racemic 1.  相似文献   

2.
A sensitive high-performance liquid chromatographic method was developed for the stereoselective assay of (R)- and (S)-propranolol in human plasma. The method involves diethyl ether extraction of the drugs and a racemic internal standard, N-tert.-butylpropranolol, followed by derivatization of the compounds with the chiral reagent (R,R)-O,O-diacetyl tartaric acid anhydride. The resulting diastereomeric derivatives were separated isocratically on a reversed-phase column. Quantitation was achieved by the peak-height ratio method with reference to the internal standard. The assay was accurate and reproducible in the concentration range 1-100 ng of (R)- and (S)-propranolol per ml plasma, using fluorescence detection at lambda ex 290 nm and lambda em 335 nm. The applicability of this method was demonstrated for the determination of concentration-time profiles of propranolol enantiomers in the course of comparative pharmacokinetic studies.  相似文献   

3.
A sensitive and selective method for the simultaneous determination of (S)-(-)-ofloxacin [(S)-(-)-OFLX] and its metabolites in serum and urine was developed using isocratic high-performance liquid chromatography with a specific solid-phase extraction procedure. (S)-(-)-OFLX and its metabolites, desmethyl-(S)-(-)-OFLX and (S)-(-)-OFLX N-oxide, were eluted from a C8 solid-phase column with recoveries of more than 98%. These compounds were separated and determined by means of a reversed-phase column with fluorimetric detection. Validation studies showed that the results were linear for (S)-(-)-OFLX in serum over the range 10-1200 ng/ml and in urine over the range 1-200 micrograms/ml. Analysis for (S)-(-)-OFLX and its metabolites showed good precision and accuracy with a relative standard deviation of less than 6%.  相似文献   

4.
A method for the simultaneous determination of disopyramide and mono-N-desisopropyldisopyramide enantiomers extracted from human plasma and urine is presented. Separation and quantitation were carried out using two columns coupled in series, and UV detection at 254 nm. First, the racemates of the two compounds were separated using a reversed-phase column, and then the enantiomers were separated using a stereoselective column packed with human alpha 1-acid glycoprotein. The mobile phase was 8 mM phosphate buffer, pH 6.20-2-propanol (92:8, v/v). The coefficients of variation (%) for the plasma daily determination were 6.7% for R(-)- and S(+)-disopyramide at drug levels of 1.5 micrograms/ml, and 8.5% and 7.7% for R(-)- and S(+)-mono-N-desisopropyldisopyramide, respectively, at drug levels of 0.375 micrograms/ml. The method has allowed the study of stereoselective metabolism and pharmacokinetics of disopyramide after oral administration as a racemate.  相似文献   

5.
A sensitive and enantiospecific gas chromatographic method for the determination of the S(+)- and R(-)-enantiomers of baclofen (I and II) in plasma and urine has been developed and validated. The method is based on the complete resolution of the derivatized enantiomers on a chiral fused-silica capillary column. The hydrochloride salt of a (-)-fluoro analogue of baclofen (III.HCl) was used as the internal standard in plasma, the hydrochloride salt of a (+)-fluoro analogue of baclofen (IV.HCl) as the internal standard in urine. Rapid and convenient isolation of the compounds was achieved using reversed-phase Bond-Elut C18 columns. After elution, the compounds were converted into isobutyl esters and purified by base-specific solvent extraction. The isobutyl esters were then N-acylated with heptafluorobutyric anhydride. The derivatives were quantitated after separation on the chiral column using electron-capture detection. The analysis of spiked plasma and urine samples demonstrated the good accuracy and precision of the method, with limits of quantitation of 25 nmol/l for I and II in plasma and of 2 mumol/l for I and II in urine. The method appears to be suitable for use in pharmacokinetic studies of the enantiomers in plasma and urine from animals and man after administration of the racemic baclofen.  相似文献   

6.
The quantitative enantiospecific determination of the beta 1-selective adrenergic antagonist (R,S)-celiprolol in human plasma and urine is described. It involves a two-step liquid-liquid extraction of celiprolol from biological material and separation of the underivatized enantiomers by high-performance liquid chromatography on a chiral stationary phase (cellulose tris-3,5-dimethylphenyl carbamate, coated on silica gel) with fluorimetric detection. R-(+)-Propranolol was used as an internal standard. The detection limits of 1.5 ng/ml enantiomer in plasma and 2.5 ng/ml enantiomer in urine at signal-to-noise ratios higher than 3 permit the performance of pharmacokinetic studies after therapeutic doses.  相似文献   

7.
A sensitive method for the simultaneous high-performance liquid chromatographic determination of clarithromycin and its active metabolite in plasma and urine is described. Alkalinized samples were coextracted with an internal standard and analyzed on a C8 column using electrochemical detection. Recoveries were greater than or equal to 85% and consistent. Standard curves for plasma were linear in the range 0-2 micrograms/ml for both compounds (r greater than 0.99), with limits of quantification of approximately 10.03 micrograms/ml (0.5-ml sample). Within-day and day-to-day precision were good, with coefficients of variation mostly within +/- 5%; accuracy for both compounds were routinely within 90-110% of theoretical values. Standard curves for urine were linear in the range 0-100 micrograms/ml with limits of quantification of 0.5 micrograms/ml (0.2-ml sample). Urine assays also had similar within-day and day-to-day precisions and accuracy.  相似文献   

8.
A sensitive and selective method was developed for the determination of (R)-ketoprofen ((R)-kt) and (S)-ketoprofen ((S)-kt) in human plasma using chiral liquid chromatography/tandem mass spectrometry (LC/MS/MS). Plasma samples spiked with stable-isotope-labeled [(13)C(1), (2)H(3)]-(R and S)-ketoprofen, for use as the internal standards, were prepared for analysis using automated solid-phase extraction (SPE) in the 96-well microtiter format. The enantiomers were separated on an (R)-1-naphthylglycine and 3,5-dinitrobenzoic acid (Chirex 3005) 250x2.0 mm i.d. analytical column, equipped with a 30x2.0 mm i.d. guard column using isocratic mobile phase conditions. The (R)- and (S)-kt levels were quantifiable from 0.05 to 2500 ng ml(-1) by constructing two separate curves from calibration standards covering the same range. The first curve ranged from 0.05 to 100 and the second from 100 to 2500 ng ml(-1). A concentration of 0.05 ng ml(-1) of either enantiomer was easily detected using a 1 ml plasma sample volume. The average method accuracy, evaluated at four levels over an extended period, was better than +/-3% over the entire range. The precision for the same set of quality control samples ranged from 4.0 to 7.0 % RSD (n = 24). The method was applied to the evaluation of pharmacokinetic parameters in human plasma obtained from volunteers who received 25 mg of kt by peroral administration of Actron caplets or by topical administration of Oruvail gel.  相似文献   

9.
[reaction: see text] (-)-(6S,7S,8S,9R,10S,2'S)-Membrenone-A and (-)-(6S,7S,8S,9R,10S)-membrenone-B were prepared in 11 steps (3% and 2.4% overall yield, respectively). Key steps included a tin(II)-mediated aldol followed by a syn selective reduction, giving the C7-C9 stereocenters, a second chain extending aldol coupling, and a p-TsOH-promoted cyclization/dehydration giving the common gamma-dihydropyrone precursor. We have thus established that synthetic (-)-(6S,7S,8S,9R,10S,2'S)-membrenone-A, (-)-(6S,7S,8S,9R,10S)-membrenone-B, and (-)-(6S,7S,8S,9R,10S)-membrenone-C are the enantiomers of the natural products.  相似文献   

10.
An isotope dilution assay for the determination of both oxaprotiline enantiomers in biological samples after administration of the racemic mixture has been developed. The enantiomers were reacted with synthetically prepared, optically pure N-trifluoroacetyl-S(-)-prolyl chloride, followed by high-performance liquid chromatographic separation of the diastereoisomers formed. Quantitation was performed by on-line UV detection at 260 nm and off-line radiometry by liquid scintillation counting. Endogenous compounds and metabolites do not interfere in the assay. Analysis of water and the blood and urine of rats spiked with [14C]oxaprotiline X HCl showed recoveries for S(+)-oxaprotiline X HCl (mean +/- coefficient of variation, n = 4-6) of 98.0 +/- 1.0% (water), 100.5 +/- 0.6% (blood) and 101.5 +/- 2.0% (urine), and for R(-)-oxaprotiline X HCl of 101.3 +/- 2.0% (water), 102.2 +/- 2.1% (blood) and 103.2 +/- 0.2% (urine). A pilot study to determine blood levels of the two enantiomers in two rats dosed with racemic [14C]oxaprotiline X HCl (10 mg/kg i.v.) was carried out to test the method. The results indicated stereoselective disposition of oxaprotiline enantiomers in the rat. The ratio of the areas under the blood concentration curves for R(-)-to S(+)-oxaprotiline X HCl was 1.14.  相似文献   

11.
A reversed-phase high-performance liquid chromatographic assay has been developed for determination of (R)-(--)-and (S)-(+)-proxyphylline in human plasma. The procedure is based on liquid-solid extraction of proxyphylline from plasma followed by derivatization of extracted proxyphylline with (--)-camphanoyl chloride. The ratio between the enantiomers is calculated from the peak areas of the corresponding diastereoisomeric proxyphylline camphanates after injection into the liquid chromatograph. The recovery of proxyphylline from plasma was 88% (coefficient of variation = 4%) and proxyphylline was detectable from a plasma concentration of 0.2 micrograms/ml. Three different plasma extraction procedures for proxyphylline using Extrelut, Bond Elut, and Chem Elut columns have been developed and compared, and the rate of derivatization of the proxyphylline enantiomers with camphanoyl chloride has been studied.  相似文献   

12.
The cyclopropane ring can be used effectively in restricting the conformation of biologically active compounds to improve activity and also to investigate bioactive conformations. We designed (1S,2R)- and (1R,2R)-2-aminomethyl-1-(1H-imidazol-4-yl)cyclopropanes (1 and 2, respectively) and their enantiomers (ent-1 and ent-2) as conformationally restricted analogues of histamine. The four types of chiral cyclopropanes bearing two differentially functionalized carbon substituents in a cis or trans relationship on a cyclopropane ring, (1S,2R)-2-(tert-butyldiphenylsilyloxy)methyl-1-formylcyclopropane (7) and (1R,2R)-2-(tert-butyldiphenylsilyloxy)methyl-1-formylcyclopropane (8) and their enantiomers (ent-7 and ent-8), were developed as the key intermediates for synthesizing 1, 2, ent-1, and ent-2. The reaction between (R)-epichlorohydrin [(R)-12] and phenylsulfonylacetonitrile (13a) in the presence of NaOEt in EtOH followed by treatment with acid gave the chiral cyclopropane lactone 11a with 98% ee in 82% yield. Compound 11a was converted into both the cis- and trans-chiral cyclopropane units 7 and 8, respectively, via reductive desulfonylation with Mg/MeOH as the key step. The corresponding enantiomers, the cis-substituted ent-7 and the trans-substituted ent-8, were also prepared starting from (S)-epichlorohydrin [(S)-12]. The four conformationally restricted target histamine analogues 1, 2, ent-1, and ent-2 were successfully synthesized from 7, 8, ent-7, and ent-8, respectively. The chiral cyclopropane units 7, 8, ent-7, and ent-8 should be useful as versatile intermediates for synthesizing various compounds having an asymmetric cyclopropane structure.  相似文献   

13.
The enantioselective synthesis of the (R,R)- and (S,S)-enantiomers of 1 from commercially available 3-chlorocinnamic acid is reported. The Sharpless asymmetric epoxidation was used to establish the stereocenters in the synthesis of both enantiomers of 1.  相似文献   

14.
The dopamine receptor agonist R(-)N-n-propylnorapomorphine (NPA) and its proposed pro-drug R(-)10,11-methylenedioxy-N-n-propylnoraporphine (MDO-NPA) were isolated simultaneously from monkey plasma using a solid-phase extraction procedure. R(-)Apomorphine (APO) and R(-)10,11-methylenedioxyaporphine (MDO-APO) were added as internal standards, and separation and quantification were by high-performance liquid chromatography with electrochemical or ultraviolet detection of the free catechol and MDO compounds, respectively. The detection limits for NPA and MDO-NPA in plasma were 0.5 and 10 ng/ml and the coefficient of variation (S.D./mean) within assays and between days of assays for both drugs was 5.6% or less. Quantification of plasma levels of NPA and MDO-NPA was possible at ranges of 2-1000 and 40-5000 ng/ml, respectively, including concentrations found after intravenous administration of these agents.  相似文献   

15.
A sensitive, stereoselective high-performance liquid chromatographic assay was developed for the resolution of the enantiomers of mexiletine as their 2-naphthoyl derivatives on a Pirkle type 1A chiral phase column. Detection of the derivatives was accomplished with a fluorescent detector. Maximum recovery of the enantiomers from plasma was 83% and was observed when plasma proteins were precipitated with a mixture of barium hydroxide-zinc sulphate. The calibration curve in plasma was linear over the concentration range 5-750 ng/ml for each enantiomer (r2 = 0.999) and in urine the linear range was 0.25-7.5 micrograms/ml (r2 = 0.999) for each enantiomer. The minimum detectable quantity of each enantiomer in plasma was 5 ng/ml at a signal-to-noise ratio of 5:1, representing 100 pg injected. A preliminary pharmacokinetic study was undertaken in one healthy male volunteer following an oral dose of 300 mg of racemic mexiletine hydrochloride. The apparent elimination half-lives determined from the plasma data were 12.1 and 14.1 h for the R(-) and S(+) enantiomers, respectively. The cumulative urinary excretion amounts of R(-)- and S(+)-mexiletine were found to be 8.01 and 10.46 mg, respectively. The plasma data indicated that a cross-over of the enantiomer ratios occurred at approximately 8 h. The urinary excretion of the enantiomers was consistent with the pattern found in plasma.  相似文献   

16.
Phenprocoumon is a commonly used oral anticoagulant of the coumarin type, and has found extensive clinical use in the treatment of thrombophlebitis, pulmonary embolism and atrial fibrillation. In the course of a clinical study to investigate the influence of genetic polymorphisms of the CYP2C9 enzyme on phenprocoumon metabolism, we developed a new enantioselective liquid chromatography/electrospray ionisation tandem mass spectrometry (LC/MS/MS) method to quantify (R)- and (S)-phenprocoumon in human plasma. HPLC separation of the enantiomers was achieved on a Chira-Grom-2 column under isocratic conditions using a water/acetonitrile/formic acid eluent. For detection and quantification a triple-quadrupole MS system was used in the selected reaction monitoring (SRM) mode. As an internal standard the structurally homologous compound warfarin was chosen. The detector response was linear with a correlation coefficient of 0.988-0.999 for (R)-phenprocoumon and 0.989-0.999 for (S)-phenprocoumon in the investigated concentration range between 62.5 and 1000 ng/mL (per enantiomer). The limit of detection (LOD) was 12.5 ng/mL.  相似文献   

17.
《Analytical letters》2012,45(11):2513-2524
Abstract

A high-performance liquid chromatographic technique for the separation of the optical isomers of salsolinol is described. The simple and rapid method allows the direct resolution of the enantiomers without derivatization. A complete separation (baseline resolution) of (R)-(+)-salsolinol and (S)-(-)-salsolinol could be achieved on a Chiral=Si 100 ß-cyclodextrin column using water mixed with 10% methanol (v/v) and 0.05% trifluoroacetic acid (v/v) as mobile phase. Analyses carried out at a flow rate of 1.0 ml/min were accomplished in less than 12 minutes.  相似文献   

18.
A quantitative method for the simultaneous high-performance liquid chromatographic (HPLC) resolution and determination of the enantiomers of 5-dimethylsulphamoyl-6,7-dichloro-2,3-dihydrobenzofuran-2-carboxyl ic acid, a new diuretic, and its N-monodemethylated metabolite in monkey plasma and urine is described. The method includes diethyl ether extraction of the samples and S-(-)-alpha-methylbenzylamide derivatization of the extract, followed by reversed-phase solid-phase extraction and injection of the resulting diastereoisomers onto a reversed-phase HPLC column. Baseline separation was obtained. The assay showed linearity over the range 0.1-50 micrograms/ml of plasma and 0.25-500 microliters of urine, with a lower limit of detection of ca. 0.01 micrograms/ml for each of the enantiomers. The method is adequate for pharmacokinetic and enantioselective disposition studies of both the diuretic and its metabolite.  相似文献   

19.
Noreximide, a sedative, is generally contaminated to some extent with its endo-isomer, norendimide, which produces excitation. A high-performance liquid chromatographic assay was developed to separate and quantitate these compounds on a 5-microns Ultrasphere ODS column with methanol-water (20:30) as mobile phase and detection at 254 nm. Assay of mixtures of these compounds in bulk material and tablets utilized isoniazide as internal standard. Peak area ratios were linear (r = 0.9999) over 1.4-66.2 micrograms of injected noreximide and 0.2-8.4 micrograms of injected norendimide. Overall percent recovery from simulated tablets containing noreximide alone was 99.6 +/- 0.8% (S.D., n = 3). Overall percent recoveries (+/- S.D.) from tablets containing a mixture of these compounds were 98.9 +/- 0.5% and 102.3 +/- 1.1% for noreximide and norendimide, respectively (n = 3). Noreximide in animal feed for long-term pharmacological studies was isolated by ether extraction and after work up, subjected to the same procedure, except that theophylline was the internal standard. Peak area ratios were linear over 0.2-19.3 micrograms of injected noreximide (r = 0.9999). Overall percent recoveries (+/- S.D., n = 3) of noreximide from spiked animal feed were 97.4 +/- 1.4% and 99.0 +/- 0.5% at the 500- and 5000-ppm levels, respectively. Limits of detection at the 95% confidence level (0.01 a.u.f.s., 20-microliters sample volume injected) were 1.67 microgram/ml and 2.56 micrograms/ml of noreximide and norendimide, respectively, in the final test solution.  相似文献   

20.
The selectivity tuning of two columns coupled in series is investigated in chiral high-performance liquid chromatography. Two columns with reversal enantioselectivities [(R,R) Whelk-O 1 and (S,S) Whelk-O 1] are coupled in series via a T connector. Selectivity of such a column series is tuned by varying the mobile phase flows in the individual columns. The flow ratio necessary for the required selectivity is calculated on the basis of retention factors measured on the individual columns. The performance of this method for adjusting the required selectivity is studied by the separation of enantiomers of alkoxy substituted esters of phenylcarbamic acid. It is demonstrated that the change of the mobile phase flows in the individual columns enables change in the elution order of enantiomers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号