首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 832 毫秒
1.
A novel microextraction technique, air-assisted liquid–liquid microextraction (AALLME), which is a new version of dispersive liquid–liquid microextraction (DLLME) method has been developed for extraction and preconcentration of phthalate esters, dimethyl phthalate (DMP), diethyl phthalate (DEP), di-iso-butyl phthalate (DIBP), di-n-butyl phthalate (DNBP), and di-2-ethylhexyl phthalate (DEHP), from aqueous samples prior to gas chromatography–flame ionization detection (GC–FID) analysis. In this method, much less volume of an organic solvent is used as extraction solvent in the absence of a disperser solvent. Fine organic droplets were formed by sucking and injecting of the mixture of aqueous sample solution and extraction solvent with a syringe for several times in a conical test tube. After extraction, phase separation was performed by centrifugation and the enriched analytes in the sedimented phase were determined by GC–FID. Under the optimum extraction conditions, the method showed low limits of detection and quantification between 0.12–1.15 and 0.85–4 ng mL−1, respectively. Enrichment factors (EFs) and extraction recoveries (ERs) were in the ranges of 889–1022 and 89–102%, respectively. The relative standard deviations (RSDs) for the extraction of 100 ng mL−1 and 500 ng mL−1 of each phthalate ester were less than 4% for intra-day (n = 6) and inter-days (n = 4) precision. Finally some aqueous samples were successfully analyzed using the proposed method and three analytes, DIBP, DNBP and DEHP, were determined in them at ng mL−1 level.  相似文献   

2.
A novel method, dispersive liquid-liquid microextraction (DLLME) coupled with high-performance liquid chromatography-variable wavelength detector (HPLC-VWD), has been developed for the determination of three phthalate esters (dimethyl phthalate (DMP), diethyl phthalate (DEP), and di-n-butyl phthalate (DnBP)) in water samples. A mixture of extraction solvent (41 μL carbon tetrachloride) and dispersive solvent (0.75 mL acetonitrile) were rapidly injected into 5.0 mL aqueous sample for the formation of cloudy solution, the analytes in the sample were extracted into the fine droplets of CCl4. After extraction, phase separation was performed by centrifugation and the enriched analytes in the sedimented phase were determined by HPLC-VWD. Some important parameters, such as the kind and volume of extraction solvent and dispersive solvent, extraction time and salt effect were investigated and optimized. Under the optimum extraction condition, the method yields a linear calibration curve in the concentration range from 5 to 5000 ng mL−1 for target analytes. The enrichment factors for DMP, DEP and DnBP were 45, 92 and 196, respectively, and the limits of detection were 1.8, 0.88 and 0.64 ng mL−1, respectively. The relative standard deviations (R.S.D.) for the extraction of 10 ng mL−1 of phthalate esters were in the range of 4.3-5.9% (n = 7). Lake water, tap water and bottled mineral water samples were successfully analyzed using the proposed method.  相似文献   

3.
In this article, a new ligandless dispersive liquid-liquid microextraction method has been developed for preconcentration of trace quantities of silver as a prior step to its determination by flame atomic absorption spectrometry. In the proposed approach, carbon tetrachloride and ethanol were used as extraction and dispersive solvents. Several factors that may be affected on the extraction process, like, extraction solvent, disperser solvent, the volume of extraction and disperser solvent, pH of the aqueous solution and extraction time were optimized. Under the optimal conditions, the calibration curve was linear in the range of 5.0 ng mL−1 to 2.0 μg mL−1 of silver with R2 = 0.9995 (n = 9) and detection limit based on three times the standard deviation of the blank (3Sb) was 1.2 ng mL−1 in original solution. The relative standard deviation for eight replicate determination of 0.5 μg mL−1 silver was ±1.5%. The high efficiency of dispersive liquid-liquid microextraction to carry out the determination of silver in complex matrices was demonstrated. The proposed method has been applied for determination of trace amount of silver in standard and water samples with satisfactory results.  相似文献   

4.
The aim of the present work is combination of the advantages of magnetic solid phase extraction (MSPE) and dispersive liquid phase microextraction (DLLME) followed by filtration-based phase separation. A new pretreatment method was developed for trace determination of megestrol acetate and levonorgestrel by liquid chromatography/ultraviolet detection in biological and wastewater samples. After magnetic solid phase extraction, the eluent of MSPE was used as the disperser solvent for DLLME. Emulsion resulted from DLLME procedure was passed through the in-line filter for phase separation. Finally the retained analytes in the filter was washed with mobile phase of liquid chromatography and transferred to the column for separation. This approach offers the preconcentration factors of 3680 and 3750 for megestrol acetate and levonorgestrel, respectively. This guarantees determination of the organic compounds at trace levels. The important parameters influencing the extraction efficiency were studied and optimized. Under the optimal extraction conditions, a linear range of 0.05–50 ng mL−1 (R2 > 0.998) and limit of detection of 0.03 ng mL−1 were obtained for megestrol acetate and levonorgestrel. Under optimal conditions, the method was successfully applied for determination of target analytes in urine and wastewater samples and satisfactory results were obtained (RSDs < 6.8%).  相似文献   

5.
A rapid and sensitive method for the determination of carbendazim (methyl benzimidazole-2-ylcarbamate, MBC) and thiabendazole (TBZ) in water and soil samples was developed by using dispersive liquid-liquid microextraction (DLLME) coupled with high performance liquid chromatography with fluorescence detection. The water samples were directly used for the DLLME extraction. For soil samples, the target analytes were first extracted by 0.1 mol L−1 HCl. Then, the pH of the extract was adjusted to 7.0 with 2 mol L−1 NaOH before the DLLME extraction. In the DLLME extraction method, chloroform (CHCl3) was used as extraction solvent and tetrahydrofuran (THF) as dispersive solvent. Under the optimum conditions, the enrichment factors for MBC and TBZ were ranged between 149 and 210, and the extraction recoveries were between 50.8 and 70.9%, respectively. The linearity of the method was obtained in the range of 5-800 ng mL−1 for water sample analysis, and 10-1000 ng g−1 for soil samples, respectively. The correlation coefficients (r) ranged from 0.9987 to 0.9997. The limits of detection were 0.5-1.0 ng mL−1 for water samples, and 1.0-1.6 ng g−1 for soil samples. The relative standard deviations (RSDs) varied from 3.5 to 6.8% (n = 5). The recoveries of the method for MBC and TBZ from water samples at spiking levels of 5 and 20 ng mL−1 were 84.0-94.0% and 86.0-92.5%, respectively. The recoveries for soil samples at spiking levels of 10 and 100 ng g−1 varied between 82.0 and 93.4%.  相似文献   

6.
A rapid and simple dispersive liquid-liquid microextraction (DLLME) has been developed to preconcentrate eighteen organochlorine pesticides (OCPs) from water samples prior to analysis by gas chromatography-mass spectrometry (GC-MS). The studied variables were extraction solvent type and volume, disperser solvent type and volume, aqueous sample volume and temperature. The optimum experimental conditions of the proposed DLLME method were: a mixture of 10 μL tetrachloroethylene (extraction solvent) and 1 mL acetone (disperser solvent) exposed for 30 s to 10 mL of the aqueous sample at room temperature (20 °C). Centrifugation of cloudy solution was carried out at 2300 rpm for 3 min to allow phases separation. Finally, 2 μL of extractant was recovered and injected into the GC-MS instrument. Under the optimum conditions, the enrichment factors ranged between 46 and 316. The calculated calibration curves gave a high-level linearity for all target analytes with correlation coefficients ranging between 0.9967 and 0.9999. The repeatability of the proposed method, expressed as relative standard deviation, varied between 5% and 15% (n = 8), and the detection limits were in the range of 1-25 ng L−1. The LOD values obtained are able to detect these OCPs in aqueous matrices as required by EPA methods 525.2 and 625. Analysis of spiked real water samples revealed that the matrix had no effect on extraction for river, surface and tap waters; however, urban wastewater sample shown a little effect for five out of eighteen analytes.  相似文献   

7.
In this work, a simple, rapid and sensitive sample pretreatment technique, dispersive liquid-liquid microextraction (DLLME) coupled with high performance liquid chromatography-fluorescence detection (HPLC-FLD), has been developed to determine carbamate (carbaryl) and organophosphorus (triazophos) pesticide residues in water and fruit juice samples. Parameters, affecting the DLLME performance such as the kind and volume of extraction and dispersive solvents, extraction time and salt concentration, were studied and optimized. Under the optimum extraction conditions (extraction solvent: tetrachloroethane, 15.0 μL; dispersive solvent: acetonitrile, 1.0 mL; no addition of salt and extraction time below 5 s), the performance of the proposed method was evaluated. The enrichment factors for the carbaryl and triazophos were 87.3 and 275.6, respectively. The linearity was obtained in the concentration range of 0.1-1000 ng mL−1 with correlation coefficients from 0.9991 to 0.9999. The limits of detection (LODs), based on signal-to-noise ratio (S/N) of 3, ranged from 12.3 to 16.0 pg mL−1. The relative standard deviations (RSDs, for 10 ng mL−1 of carbaryl and 20 ng mL−1 of triazophos) varied from 1.38% to 2.74% (n = 6). The environmental water (at the fortified level of 1.0 ng mL−1) and fruit juice samples (at the fortified level of 1.0 and 5.0 ng mL−1) were successfully analyzed by the proposed method, and the relative recoveries of them were in the range of 80.4-114.2%, 89.8-117.9% and 86.3-105.3%, respectively.  相似文献   

8.
Dispersive liquid-liquid microextraction (DLLME) technique was successfully used as a sample preparation method for graphite furnace atomic absorption spectrometry (GF AAS). In this extraction method, 500 μL methanol (disperser solvent) containing 34 μL carbon tetrachloride (extraction solvent) and 0.00010 g ammonium pyrrolidine dithiocarbamate (chelating agent) was rapidly injected by syringe into the water sample containing cadmium ions (interest analyte). Thereby, a cloudy solution formed. The cloudy state resulted from the formation of fine droplets of carbon tetrachloride, which have been dispersed, in bulk aqueous sample. At this stage, cadmium reacts with ammonium pyrrolidine dithiocarbamate, and therefore, hydrophobic complex forms which is extracted into the fine droplets of carbon tetrachloride. After centrifugation (2 min at 5000 rpm), these droplets were sedimented at the bottom of the conical test tube (25 ± 1 μL). Then a 20 μL of sedimented phase containing enriched analyte was determined by GF AAS.Some effective parameters on extraction and complex formation, such as extraction and disperser solvent type and their volume, extraction time, salt effect, pH and concentration of the chelating agent have been optimized. Under the optimum conditions, the enrichment factor 125 was obtained from only 5.00 mL of water sample. The calibration graph was linear in the rage of 2-20 ng L−1 with detection limit of 0.6 ng L−1. The relative standard deviation (R.S.D.s) for ten replicate measurements of 20 ng L−1 of cadmium was 3.5%. The relative recoveries of cadmium in tap, sea and rivers water samples at spiking level of 5 and 10 ng L−1 are 108, 95, 87 and 98%, respectively. The characteristics of the proposed method have been compared with cloud point extraction (CPE), on-line liquid-liquid extraction, single drop microextraction (SDME), on-line solid phase extraction (SPE) and co-precipitation based on bibliographic data. Therefore, DLLME combined with GF AAS is a very simple, rapid and sensitive method, which requires low volume of sample (5.00 mL).  相似文献   

9.
In this study, a sample pretreatment method was developed for the determination of 13 endocrine disrupting chemicals (EDCs) in sediment samples based on the combination of subcritical water extraction (SWE) and dispersed liquid–liquid microextraction (DLLME). The subcritical water that provided by accelerated solvent extractor (ASE) was the sample solution (water) for the following DLLME and the soluble organic modifier that spiked in the subcritical water was also used as the disperser solvent for DLLME in succession. Thus, several important parameters that affected both SWE and DLLME were investigated, such as the extraction solvent for DLLME (chlorobenzene), extraction time for DLLME (30 s), selection of organic modifier for SWE (acetone), volume of organic modifier (10%) and extraction temperature for SWE (150 °C). In addition, good chromatographic behavior was achieved for GC–MS after derivatisation by using N,O-bis(trimethylsilyl) trifluoroacetamide (BSTFA). As a result, proposed method sensitive and reliable with the limits of detection (LODs) ranging from 0.006 ng g−1 (BPA) to 0.639 ng g−1 (19-norethisterone) and the relative standard deviations (RSDs) between 1.5% (E2) and 15.0% (DES). Moreover, the proposed method was compared with direct ASE extraction that reported previously, and the results showed that SWE–DLLME was more promising with recoveries ranging from 42.3% (dienestrol) to 131.3% (4,5α-dihydrotestosterone), except for diethylstilbestrol (15.0%) and nonylphenols (29.8%). The proposed method was then successfully applied to determine 13 EDCs sediment of Humen outlet of the Pearl River, 12 of target compounds could be detected, and 10 could be quantitative analysis with the total concentration being 39.6 ng g−1, and which indicated that the sediment of Humen outlet was heavily contaminated by EDCs.  相似文献   

10.
Dispersive liquid–liquid microextraction (DLLME) has been proved to be a powerful tool for the rapid sample treatment of liquid samples providing at the same time high enrichment factors and extraction recoveries. A new, simple and easy to handle one step in-syringe set-up for DLLME is presented and critically discussed in this paper. The novel approach avoids the centrifugation step, typically off-line and time consuming, opening-up a new horizon on DLLME automation. The suitability of the proposal is evaluated by means of the determination of non-steroidal anti-inflammatory drugs in urine by liquid chromatography/ultraviolet detection. In the presented approach an ionic liquid is used as extractant. The target drugs can be determined in urine within the concentration range 0.02–10 μg mL−1, allowing their determination at therapeutic and toxic levels. Limits of detection were in the range from 8.3 ng mL−1 (indomethacin) to 32 ng mL−1 (ketoprofen). The repeatability of the proposed method expressed as RSD (n = 5) varied between 2.5% (for ketoprofen) and 8.6% (for indomethacin).  相似文献   

11.
A new micelle-mediated cloud point extraction method is described for sensitive and selective determination of trace amounts of rhodamine B by spectrophotometry. The method is based on the cloud point extraction of rhodamine B from aqueous solution using Triton X-100 in acidic media. The extracted surfactant rich phase is diluted with water and its absorbance is measured at 563 nm by a spectophotometer. The effects of different operating parameters such as concentration of surfactant and salt, temperature and pH on the cloud point extraction of rhodamine B were studied in details and a set of optimum conditions were obtained. Under optimum conditions a linear calibration graph in the range of 5-550 ng mL−1 of rhodamine B in the initial solution with r = 0.9991 (n = 15) was obtained. Detection limit based on three times the standard deviation of the blank (3Sb) was 1.3 ng mL−1 (n = 10) and the relative standard deviation (R.S.D.) for 50 and 350 ng mL−1 of rhodamine B was 2.40 and 0.87% (n = 10), respectively. The method was applied for the determination of rhodamine B in soft pastel, hand washing liquid soap, matches tip and textile dyes mixture samples.  相似文献   

12.
Dispersive liquid–liquid microextraction (DLLME) coupled with high-performance liquid chromatography (HPLC)-UV detection was applied for the extraction and determination of bisphenol A (BPA) in water samples. An appropriate mixture of acetone (disperser solvent) and chloroform (extraction solvent) was injected rapidly into a water sample containing BPA. After extraction, sedimented phase was analyzed by HPLC-UV. Under the optimum conditions (extractant solvent: 142 μL of chloroform, disperser solvent: 2.0 mL of acetone, and without salt addition), the calibration graph was linear in the range of 0.5–100 μg L−1 with the detection limit of 0.07 μg L−1 for BPA. The relative standard deviation (RSD, n = 5) for the extraction and determination of 100 μg L−1 of BPA in the aqueous samples was 6.0%. The results showed that DLLME is a very simple, rapid, sensitive and efficient analytical method for the determination of trace amount of BPA in water samples and suitable results were obtained.  相似文献   

13.
An improved method for the determination of metacrate in water samples has been developed using dispersive liquid-liquid microextraction (DLLME) prior to liquid chromatography analysis. The variables of interest, such as the volume of extraction solvent and disperser solvent, salt effect, sample volume, and extraction time in the DLLME process, were optimized with the aid of response surface methodology and experimental design (RSM). Firstly, an orthogonal array design (OAD) was used to choose the significant variables for the optimization. Secondly, the significant factors were optimized by using a central composite design (CCD) and the quadratic model between the dependent and the independent variables was built. The proposed method showed good agreement between the experimental data and predictive value, and it has been successfully employed to determine metacrate in water samples. The limit of detection was 1 ng mL−1 and, repeatability of the method, described as relative standard deviation, was 5.7% (n = 5).  相似文献   

14.
Li Y  Wei G  Hu J  Liu X  Zhao X  Wang X 《Analytica chimica acta》2008,615(1):96-103
A simple, rapid and efficient method, dispersive liquid-liquid microextraction (DLLME), has been developed for the extraction and preconcentration of polybrominated diphenyl ethers (PBDEs) in water samples. The factors influencing microextraction efficiencies, such as the kind and volume of extraction and dispersive solvent, the extraction time and the salt effect, were optimized. Under the optimum conditions (sample volume: 5 mL; extraction solvent: tetrachloroethane, 20.0 μL; dispersive solvent: acetonitrile, 1.00 mL; extraction time: below 5 s and without salt addition), the enrichment factors and extraction recoveries were high and ranged from 268 to 305 and 87.0 to 119.1%, respectively. Linearity was observed in the range 0.05-50 ng mL−1 for BDE-28 and BDE-99, and 0.1-100 ng mL−1 for BDE-47 and BDE-209, respectively. Coefficients of correlation (r2) ranged from 0.9995 to 0.9999. The repeatability study was carried out by extracting the spiked water samples at concentration levels of 50 ng mL−1 for BDE-28 and BDE-99, and 100 ng mL−1 for BDE-47 and BDE-209, respectively. The relative standard deviations (R.S.D.s) varied between 3.8 and 6.3% (n = 5). The limits of detection (LODs), based on signal-to-noise ratio (S/N) of 3, ranged from 12.4 to 55.6 pg mL−1 (the wavelength of detector at 226 nm). The relative recoveries of PBDEs from tap, lake water and landfill leachate samples at spiking levels of 5, 10 and 50 ng mL−1 were in the range of 89.7-107.6%, 114.3-119.1% and 87.0-90.9%, respectively. As a result, this method can be successfully applied for the determination of PBDEs in landfill leachate and environmental water samples.  相似文献   

15.
In the present study, a rapid, highly efficient and environmentally friendly sample preparation method named ionic liquid-based ultrasound-assisted dispersive liquid–liquid microextraction (IL-USA-DLLME), followed by high performance liquid chromatography (HPLC) has been developed for the extraction and preconcentration of four benzophenone-type ultraviolet (UV) filters (viz. benzophenone (BP), 2-hydroxy-4-methoxybenzophenone (BP-3), ethylhexyl salicylate (EHS) and homosalate (HMS)) from three different water matrices. The procedure was based on a ternary solvent system containing tiny droplets of ionic liquid (IL) in the sample solution formed by dissolving an appropriate amount of the IL extraction solvent 1-hexyl-3-methylimidazolium tris(pentafluoroethyl)trifluorophosphate ([HMIM][FAP]) in a small amount of water-miscible dispersive solvent (methanol). An ultrasound-assisted process was applied to accelerate the formation of the fine cloudy solution, which markedly increased the extraction efficiency and reduced the equilibrium time. Various parameters that affected the extraction efficiency (such as type and volume of extraction and dispersive solvents, ionic strength, pH and extraction time) were evaluated. Under optimal conditions, the proposed method provided good enrichment factors in the range of 354–464, and good repeatability of the extractions (RSDs below 6.3%, n = 5). The limits of detection were in the range of 0.2–5.0 ng mL−1, depending on the analytes. The linearities were between 1 and 500 ng mL−1 for BP, 5 and 500 ng mL−1 for BP-3 and HMS and 10 and 500 ng mL−1 for EHS. Finally, the proposed method was successfully applied to the determination of UV filters in river, swimming pool and tap water samples and acceptable relative recoveries over the range of 71.0–118.0% were obtained.  相似文献   

16.
A novel on-line sequential injection (SI) dispersive liquid-liquid microextraction (DLLME) system coupled to electrothermal atomic absorption spectrometry (ETAAS) was developed for metal preconcentration in micro-scale, eliminating the laborious and time consuming procedure of phase separation with centrifugation. The potentials of the system were demonstrated for trace lead and cadmium determination in water samples. An appropriate disperser solution which contains the extraction solvent (xylene) and the chelating agent (ammonium pyrrolidine dithiocarbamate) in methanol is mixed on-line with the sample solution (aqueous phase), resulting thus, a cloudy solution, which is consisted of fine droplets of xylene, dispersed throughout the aqueous phase. Three procedures are taking place simultaneously: cloudy solution creation, analyte complex formation and extraction from aqueous phase into the fine droplets of xylene. Subsequently the droplets were retained on the hydrophobic surface of PTFE-turnings into the column. A part of 30 μL of the eluent (methyl isobutyl ketone) was injected into furnace graphite for analyte atomization and quantification. The sampling frequency was 10 h−1, and the obtained enrichment factor was 80 for lead and 34 for cadmium. The detection limit was 10 ng L−1 and 2 ng L−1, while the precision expressed as relative standard deviation (RSD) was 3.8% (at 0.5 μg L−1) and 4.1% (at 0.03 μg L−1) for lead and cadmium respectively. The proposed method was evaluated by analyzing certified reference materials and was applied to the analysis of natural waters.  相似文献   

17.
A new analytical method based on simultaneous derivatization and dispersive liquid–liquid microextraction (DLLME) followed by gas chromatography–mass spectrometry (GC–MS), for the determination of the allergenic compounds atranol and chloroatranol in perfumes, is presented. Derivatization of the target analytes by means of acetylation with anhydride acetic in carbonate buffer was carried out. Thereby volatility and detectability were increased for improved GC–MS sensitivity. In addition, extractability by DLLME was also enhanced due to a less polar character of the solutes. A liquid–liquid extraction was performed before DLLME to clean up the sample and to obtain an aqueous sample solution, free of the low polar matrix from the essential oils, as donor phase. Different parameters, such as the nature and volume of both the extraction and disperser solvents, the ionic strength of the aqueous donor phase or the effect of the derivatization reagent volume, were optimized. Under the selected conditions (injection of a mixture of 750 μL of acetone as disperser solvent, 100 μL of chloroform as extraction solvent and 100 μL of anhydride acetic as derivatization reagent) the figures of merit of the proposed method were evaluated. Limits of detection in the low ng mL−1 range were obtained. Matrix effect was observed in real perfume samples and thus, standard addition calibration is recommended.  相似文献   

18.
In this research, a novel microextraction technique based on ionic liquids (ILs) termed cold-induced aggregation microextraction (CIAME) is developed. In this method, very small amounts of 1-hexyl-3-methylimidazolium hexafluorophosphate [Hmim][PF6] and 1-hexyl-3-methylimidazolium bis (trifluoromethylsulfonyl) imide [Hmim][Tf2N] (as extractant solvents) were dissolved in a sample solution containing Triton X-114 (as an anti-sticking agent). Afterwards, the solution was cooled in the ice bath and a cloudy solution was formed. After centrifuging, the fine droplets of extractant phase were settled to the bottom of the conical-bottom glass centrifuge tube.CIAME is a simple and rapid method for extraction and preconcentration of metal ions from water samples and can be applied for the sample solutions containing high concentration of salt and water miscible organic solvents. Furthermore, this technique is much safer in comparison with the organic solvent extraction.Performance of the technique was evaluated by determination of the trace amounts of mercury as a test analyte in several real water samples. Michler thioketone (TMK) was chosen as a complexing agent. Analysis was carried out using spectrophotometric detection method. Type and amount of IL and the surfactant, temperature and the other parameters were optimized. Under the optimum conditions, the limit of detection (LOD) of the method was 0.3 ng mL−1 and the relative standard deviation (R.S.D.) was 1.32% for 30 ng mL−1 mercury.  相似文献   

19.
In the present work, a new ligandless-dispersive liquid-liquid microextraction (LL-DLLME) method has been developed for preconcentration trace amounts of copper as a prior step to its determination by flame atomic absorption spectrometry. In the proposed approach 1,2-dicholorobenzene and ethanol were used as extraction and dispersive solvents, respectively. Some factors influencing on the extraction efficiency of copper and its subsequent determination were studied and optimized, such as the extraction and dispersive solvent type and volume, pH of sample solution, extraction time and salting out effect. Under the optimal conditions, the calibration curve was linear in the range of 1.0 ng mL−1-0.6 μg mL−1 of copper with R2 = 0.9985. Detection limit was 0.5 ng mL−1 in original solution (3Sb/m) and the relative standard deviation for seven replicate determination of 0.2 μg mL−1 copper was ±1.4%. The proposed method has been applied for determination of copper in standard and water samples with satisfactory results.  相似文献   

20.
A new suspension array built upon laboratory-prepared functional fluorescence-encoded polystyrene beads (FFPBs) was developed for multiplex immunodetection of tumor markers. The FFPBs were synthesized by copolymerizing rhodamine 6G (R6G) and carboxyl function groups on the surface of the seed beads forming a core-shell structure. The fabrication process was facile and the encoding fluorescence intensity of the beads can be precisely controlled by adjusting the quantity of R6G. In present work, we demonstrated that the quantity variation of impregnated R6G had negligible effect on the coupling efficiency of biomolecules onto the surface of the FFPBs. The R6G encoding fluorescence remained good monodispersity upon capture probe coupling and immunocomplex formation. No fluorescence resonance energy transfer was observed between the R6G doped in the bead shell and fluorophore used for antibody labeling. Under the optimal conditions, the proposed suspension array allowed simultaneous detection of α-fetoprotein, carcinoembryonic antigen, and prostate specific antigen in the ranges of 0.07-500 ng mL−1, 1-2000 ng mL−1, and 0.5-500 ng mL−1, respectively, with detection limits of 0.0626 ng mL−1, 0.554 ng mL−1, and 0.250 ng mL−1. Test on clinical serum samples demonstrated that the results obtained with suspension array were in good agreement with those of the reference electrochemiluminescence immunoassay method. We conclude that the laboratory-made FFPBs are sufficient as the microcarrier for the construction of suspension array in clinical diagnosis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号