首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A group selective molecularly imprinted solid phase extraction (MISPE) for malachite green (MG) from fish water and fish feed samples was developed. Using MG as template molecule, methacrylic acid as functional monomer, ethylene glycoldimethacrylate as linking agent and bulk polymerization as synthetic method, the molecularly imprinted polymers (MIPs) were synthesized and characterized with rebinding experiment. The Scatchard polt's analysis revealed that the template-polymer system showed the two-site binding behavior with dissociation constants of 0.3194 μmol L−1 and 15.70 μmol L−1, respectively. MG and two structurally related compounds, leucomalachite green (LMG) and crystal violet (CV) were employed for selectivity test. The MIPs exhibited the highest selective rebinding to MG, but also displayed 83.0% and 87.5% of cross-reactivity with LMG and CV, demonstrating that MIPs could be used as group recognition sorbents in solid phase extraction. The extraction conditions of MISPE column for MG were optimized. Tap water samples spiked with MG at concentration of 0.5-10 ng mL−1 were extracted by MISPE column and analyzed by high performance liquid chromatography. The recoveries of MISPE column for MG extraction were found to be 76.8-93.7% with the relative standard deviations of 2.12-10.09%, indicating the feasibility of the prepared MIPs for MG extraction. No detectable MG was observed in one fish farming water sample and two fish feed samples; while the MG concentrations in two pet fishpond water samples were found at 1.50 ng mL−1 and 0.67 ng mL−1, respectively.  相似文献   

2.
A novel and sensitive extraction procedure using maghemite nanoparticles (γ-Fe2O3) modified with sodium dodecyl sulfate (SDS), as an efficient solid phase, was developed for removal, preconcentration and spectrophotometric determination of trace amounts of malachite green (MG) and leuco-malachite green (LMG). Combination of nanoparticle adsorption and easily magnetic separation was used to extraction and desorption of MG and LMG. The adsorption capacity was evaluated using both the Langmuir and Freundlich adsorption isotherm models. Maghemite nanoparticles were prepared by co-precipitation method and their surfaces were modified by SDS. The size and properties of the produced maghemite nanoparticles was determined by X-ray diffraction (XRD) analysis, scanning electron microscopy (SEM) and BET analysis. MG and LMG became adsorbed at pH 3.0. LMG was oxidized to MG by adsorption on maghemite nanoparticles. The adsorbed MG was then desorbed and determined spectrophotometrically. The calibration graph was linear in the range 0.50-250.00 ng mL−1 of MG and LMG with a correlation coefficient of 0.9991. The detection limit of the method for determination of MG was 0.28 ng mL−1 and the relative standard deviation (R.S.D.) for 10.00 and 50.00 ng mL−1 of malachite green was 1.60% (n = 3) and 0.86% (= 5), respectively. A preconcentration factor of 50 was achieved in this method. The Langmuir adsorption capacity (qmax) was found to be 227.3 mg g−1 of the adsorbent. The method was applied to the determination of MG in fish farming water samples.  相似文献   

3.
A sorbent was synthesized and investigated for molecularly imprinted solid-phase extraction (MISPE). Molecularly imprinted polymers (MIPs) were synthesized via precipitation polymerization procedure, where methacrylic acid (MAA) was used as functional monomer and ethylene glycol dimethacrylate (EDMA) as cross-linking agent. The imprinting effect and selectivity of the MISPE were evaluated by elution experiments. The resulting MISPE showed high extraction selectivity to malachite green, gentian violet and their metabolites, which may be caused by both the ion exchange and the hydrophobic interactions. The determination of multi-residue for malachite green, gentian violet and their metabolites in aquatic products by HPLC coupled with MISPE was also investigated. The mean recoveries calculated by solvent calibration curve for malachite green (MG), gentian violet (GV), leucomalachite green (LMG) and leucogentian violet (LGV) were from 89.8% to 99.1% for grass carp, 90.6% to 101.2% for shrimp and 91.3% to 96.3% for shellfish. The decision limit (CCα) and the detection capability (CCβ) obtained for MG, GV, LMG and LGV were in the range of 0.11–0.14 and 0.19–0.24 μg kg−1 for grass carp, shrimp and shellfish. The MISPE was successfully used off-line for the determination of MG, GV and their metabolites in aquatic products.  相似文献   

4.
This paper reports a multiresponse optimization of an extraction procedure in the simultaneous determination of malachite green (MG) and its metabolite (leucomalachite green, LMG) in fish by liquid chromatography with triple quadrupole mass spectrometry (LC–MS/MS). Prior to optimization, the active factors of the extraction procedure were determined by a screening experimental design. Then, in the optimal experimental conditions of the extraction, MG and LMG have been determined by using a three-way calibration model based on parallel factor analysis (PARAFAC). The procedure fulfils the performance requirements for a confirmatory method established by the European Union Decision 2002/657/EC. This norm establishes maximum permitted tolerances for relative abundance of the precursor/product ion pairs. There is a reported contradiction in the literature related to the fact that there are standard samples whose concentration is greater than CCα but the maximum permitted tolerances are not fulfilled in the identification of the analytes. In this work, it is shown that with the information provided by PARAFAC this contradiction is avoided. The figures of merit for PARAFAC and univariate calibration procedures were evaluated under optimal conditions in the extraction step. The figures of merit obtained were in the range of 0.13–0.23 μg kg−1 for the decision limit, CCα, (α = 0.01) and 0.22–0.39 μg kg−1 for the detection capability, CCβ, (β = 0.05), whereas mean relative errors in absolute value were in the range of 2.8–4.6% for MG and LMG with PARAFAC calibration. The proposed optimized extraction procedure using a PARAFAC calibration was also applied in the determination of MG and LMG in gilthead bream samples: the decision limit was in the range of 0.45–0.55 μg kg−1, the detection capability was in the range of 0.76–0.92 μg kg−1 for MG and LMG. Trueness was likewise confirmed and the mean of the absolute values of relative errors were between 4.2% and 7.2%.  相似文献   

5.
A rapid easy-to-use trace level direct competitive enzyme-linked immunosorbent assay (dc-ELISA) detection of total residual malachite green (MG), crystal violet (CV) and their corresponding primary metabolites leucomalachite green (LMG) and leucocrystal violet (LCV) in fishery products in a single assay was developed. The monoclonal antibodies, anti-MG and anti-CV mAbs, were prepared using carboxyl-malachite green (CMG) and cationized bovine serum albumin (cBSA) conjugates as immunogen. The linear range for the quantitative detection of total MG, CV and their primary metabolites LMG and LCV was between 0.15 to 4.5?ng?mL?1 with a half maximal inhibitory concentration (IC50) at 0.56?±?0.04?ng?mL?1 (n?=?5). The anti-MG mAbs exhibited 98% cross-reactivity to CV, less than 0.1% cross-reactivity with LMG and LCV, and no cross-reactivity with chloramphenicol, enrofloxacin, sulfadiazine, and tetracycline. Application of the dc-ELISA in fish tissue samples gave a limit of detection (LOD) of 0.37?ng?g?1. The improved total detection lead to a recovery of 74.60?±?8.38% at 0.5?ng?g?1 and 87.47?±?12.83% at 2.0?ng?g?1 that was better than existing techniques. The dc-ELISA showed total MG in 7 out of 44 field fish samples that were confirmed with LC-MS/MS. The easy-to-use, inexpensive, and rapid dc-ELISA for the detection of total MG, CV and their corresponding primary metabolites holds promise for field applications.  相似文献   

6.
Masson JF  Obando L  Beaudoin S  Booksh K 《Talanta》2004,62(5):865-870
A sensor to detect markers of cardiac muscle cell death at less than 3 ng ml−1 and in less than 10 min has been achieved. This fiber-optic-based surface plasmon resonance (SPR) sensor is being applied to detect myoglobin (MG) and cardiac troponin I (cTnI) in HEPES buffered saline solution. An in vivo sensor for the early detection of the onset of myocardial infarction (MI) will greatly enhance the patient care. MG and cTnI are two biological markers released from dying cardiac muscle cells during an MI, and their detection at biologically-relevant levels can be diagnostic of MI. Antibodies specific to an antigen of interest are attached to a carboxymethylated dextran layer on a gold SPR surface. With the method developed, the lower limit of detection (LOD) for MG is 2.9 ng ml−1 at 25 °C. The biological level for MG reaches 15-30 ng ml−1 in patient blood after myocardial damage. A Langmuir adsorption isotherm describes the binding well. For cTnI, a lower detection limit of 1.4 ng ml−1 was achieved in preliminary tests. cTnI levels are in the range of 1-3 ng ml−1 in patient blood after myocardial damage. The antibody reaction with the carboxymethylated dextran surface was optimized by modifying the reaction pH, the temperature, and the dextran chain length.  相似文献   

7.
Molecularly imprinted (MIP) and blank polymers with affinity for nonylphenol were designed using computational modelling. Chromatographic tests demonstrated higher affinity of imprinted polymers towards the template nonylphenol as compared with blank polymers. The performance of both polymers in solid-phase extraction was however very similar. Both blank and imprinted polymers appeared to be suitable for the removal and pre-concentration of nonylphenol from contaminated water samples with 99% efficiency of the recovery. The commercial resins PH(EC) (Biotage) and C18 (Varian) tested in the same conditions used for comparative purposes had recovery rate <84%. The polymer capacity for nonylphenol was 231 mg g−1 for blank and 228 mg g−1 for MIP. The synthesised materials can have significance for sample pre-concentration and environmental analysis of this class of compounds.  相似文献   

8.
Chih-Hsin Tsai 《Talanta》2007,72(2):368-372
A capillary electrophoresis Raman spectroscopy (CE-RS) method based on the stacking and sweeping modes are described. A non-fluorescent compound (malachite green, MG; crystal violet, CV) and a doubled Nd:YAG laser (532 nm, 300 mW) were selected as the model compound and light source, respectively. In order to carry out a quantitative and analysis of MG, a monochromator was used to collect the specific Raman line at 1616 cm−1 (the N-φ and C-C stretching, corresponding to 582 nm when the wavelength of the exciting source is 532 nm). The limit of detection (LOD) for MG was 1.6 × 10−5 and 1.1 × 10−5 M, respectively, based on the CZE and MEKC modes. This could be improved to 3.4 × 10−7 and 5.3 × 10−9 M, respectively, when the stacking and sweeping modes were applied. The method was also extended to the determination of MG in an actual sample.  相似文献   

9.
Highly selective molecularly imprinted polymers (MIPs) for solid-phase extraction and determination of furosemide in human plasma have been designed and prepared. In order to study the intermolecular interactions in the pre-polymerization mixture and to find a suitable functional monomer in MIP preparation, a computational approach was developed. It was based on the comparison of the binding energy of the complexes between the template and functional monomers. Having confirmed the results of computational method, three MIPs were synthesized with different functional monomers, i.e. acrylamide (AAM), 4-vinylpiridine (4-VP) and acrylonitrile (ACN), and then evaluated using Langmuir-Freundlich (LF) isotherm. Using the MIP prepared by AAM as functional monomer, a molecularly imprinted solid-phase extraction procedure followed by high performance liquid chromatography with ultraviolet detector (MISPE-HPLC-UV) was developed for selective extraction and determination of furosemide in human plasma. For the proposed MISPE-HPLC-UV method, the linearity between responses (peak area) and concentration was found over the range of 75-3500 ng mL−1 with a linear regression coefficient (R2) of 0.997. The limit of detection (LOD) and quantification (LOQ) in plasma were 12.9 and 43.3 ng mL−1, respectively.  相似文献   

10.
A novel and sensitive cloud point extraction procedure for the determination of trace amounts of malachite green by spectrophotometry was developed. Malachite green was extracted at pH 2.5 mediated by micelles of nonionic surfactant Triton X-100. The extracted surfactant-rich phase was diluted with ethanol and its absorbance was measured at 630 nm. The effect of different variables such as pH, Triton X-100 concentration, cloud point temperature and time and diverse ions was investigated and optimum conditions were established. The calibration graph was linear in the range of 4-500 ng mL−1 of malachite green in the initial solution with r = 0.9996 (n = 10). Detection limit based on three times the standard deviation of the blank (3Sb) was 1.2 ng mL−1 and the relative standard deviation (R.S.D.) for 20 and 300 ng mL−1 of malachite green was 1.48 and 1.13% (n = 8), respectively. The method was applied to the determination of malachite green in different fish farming and river water samples.  相似文献   

11.
Fenitrooxon [O,O-dimethyl-O-(4-nitro-m-tolyl)phosphate] is the major metabolite of the organophosphorus insecticide fenitrothion, and 3-methyl-4-nitrophenol is its major degradation product. In the present study, we describe the development of an indirect competitive enzyme-linked immunosorbent assay (ELISA) for the detection of these compounds in water samples based on a group-specific polyclonal antiserum generated with a “bifunctional hapten”, which has two functions: the conventional function of producing an antibody against an antigen and a unique function of promoting the production of the antibodies in rabbit. For application to water samples, the influence of several factors such as organic solvent, pH, and detergent was studied. Under optimized conditions, the quantitative working range of the fenitrooxon ELISA was 0.71-27 ng ml−1 with a limit of detection (LOD) of 0.32 ng ml−1, and the fenitrooxon concentration giving 50% reduction of the maximum signal (IC50) was 4.2 ng ml−1. The quantitative working range of the 3-methyl-4-nitrophenol ELISA was 0.67-27 ng ml−1 with a LOD of 0.38 ng ml−1 and an IC50 of 3.7 ng ml−1. No significant matrix effect originating from the water sample (river water, tap water, purified water, and bottled water) was shown by addition of Tween 20 to the assay buffer. Water samples spiked with each of these compounds at 1, 5, 10, and 20 ng ml−1 were directly analyzed without extraction and clean-up by the proposed ELISA. The mean recovery was 100.9%, and the mean coefficient of variation (CV) was 7.7% for the fenitrooxon ELISA and for the 3-methyl-4-nitrophenol ELISA, the mean recovery was 97.6%, and the mean CV was 7.2%. The proposed ELISA allows precise and accurate determination of these compounds in water at such low levels.  相似文献   

12.
He Q  Chang X  Wu Q  Huang X  Hu Z  Zhai Y 《Analytica chimica acta》2007,605(2):192-197
A new functional monomer N-(o-carboxyphenyl)maleamic acid (CPMA) was synthesized and chosen for the preparation of surface-grafted ion-imprinted polymers (IIPs) specific for thorium(IV). Polymerizable double bond was introduced to silica gel surface by amidation reaction between -NH2 and maleic anhydride. In the ion-imprinting process, thorium(IV) was complexed with the carboxyl groups, then was imprinted in the polymers grafted to the silica gel surface. The imprinted Th(IV) was removed with 3 mol L−1 HCl. The obtained imprinted particles exhibited excellent selectivity and rapid kinetics process for Th(IV). The relatively selective factor (αr) values of Th(IV)/La(III), Th(IV)/Ce(III), Th(IV)/Nd(III), Th(IV)/U(VI), and Th(IV)/Zr(IV) were 85.7, 88.9, 26.6, 64.4, and 433.8, respectively, which were greater than 1. The precision (R.S.D.), the detection limit (3σ), and the quantification limit (10σ) of the method were 1.9%, 0.51 ng mL−1 and 1.19 ng mL−1, respectively. The prepared IIPs as solid-phase extractants were successfully applied for the preconcentration of trace thorium in natural and certified samples prior to its determination by inductively coupled plasma atomic emission spectrometry (ICP-AES) with satisfactory results.  相似文献   

13.
Molecularly imprinted polymer gel film on the gold substrate of a chip was prepared with minute amount of cross-linker for the fabrication of a surface plasmon resonance (SPR) sensor sensitive to 3,3′-dichlorobenzidine. The molecularly imprinted gel film was anchored on a gold chip by a surface-bound photo-radical initiator. The sensing of 3,3′-dichlorobenzidine is based on responsive shrinkage of the imprinted polymer gel film that is triggered by target binding. This change can improve the responsiveness of the imprinted SPR sensor to 3,3′-dichlorobenzidine. The molecularly imprinted polymer gel film was characterized with contact angle measurements, electrochemical impedance spectroscopy, cyclic voltammogram, swelling measurements and atomic force microscopy. The changes of SPR spectroscopy wavenumber shifts revealed that the imprinted gel sensing film can ‘memorize’ the binding of 3,3′-dichlorobenzidine compared to non-imprinted one. The imprinted gel-SPR sensor showed a linear response in the range of 9.0 × 10−12 to 5.0 × 10−10 mol L−1 (R2 = 0.9998) for the detection of 3,3′-dichlorobenzidine, and it also exhibited high selectivity to 3,3′-dichlorobenzidine compared to its structurally related analogues. We calculated the detection limits to be 0.471 ng L−1 for tap water and 0.772 ng kg−1 for soil based on a signal to noise ratio of 3. The method showed good recoveries and precision for the samples spiked with 3,3′-dichlorobenzidine. This suggest that the imprinted gel-SPR sensing method can be used as a promising alternative for the detection of 3,3′-dichlorobenzidine.  相似文献   

14.
A simple and sensitive kinetic method for the determination of traces of mercury (70-760 ng ml−1) based on its inhibitory effect on the addition reaction between methyl green and sulfite ion is proposed. The reaction was monitored spectrophotometrically by measuring the decrease in absorbance of methyl green at 596 nm between 2 and 4 min using a fixed time method. Artificial neural networks with back propagation algorithm coupled with an orthogonal array design were applied to the modeling of the proposed kinetic system and optimization of experimental conditions. An orthogonal design was utilized to design the experimental protocol, in which pH, concentration of sulfite, temperature, and concentration of methyl green were varied simultaneously. Optimum experimental conditions in term of sensitivity were generated by using ANNs. The rate of decrease in absorbance is inversely proportional to the concentration of Hg(II) over entire concentration range tested (100-550 ng ml−1) with a detection limit of 45 ng ml−1 and a relative standard deviation at 200-400 ng ml−1 Hg(II) of 3.2% (n=5). A simple preconcentration step improved the limit of detection and linear dynamic range of the method to about 8 and 12-760 ng ml−1, respectively, by about 10 times enrichment of mercury between 12 and 75 ng ml−1. The method was based on enrichment of Hg(II) from dilute samples on an anionic ion exchanger fixed on a plastic strip and was applied to the determination of Hg(II) in environmental samples with satisfactory results.  相似文献   

15.
Molecularly imprinted polymer (MIP) may not selectively recognize small template of limited number of functional groups, such as 2-chlorophenol (2-CP). In this work, a novel method was proposed to improve the recognition ability of the molecularly imprinted solid phase extraction (MISPE) of 2-CP from environmental waters. This was achieved by derivatization of 2-CP with 4-amino-anti-pyrine (4-AAP) to enlarge its molecular size and add more binding sites. For that purpose, two MISPE methods of 2-CP were developed. In method 1, a polymer imprinted with 2-CP was used as the extracting sorbent but it suffered from low selectivity and high detection limit of 2-CP (7.10 ng L−1). In method 2, a polymer imprinted with 4-AAP derivatized 2-CP (2-CP-4-AAP) was used as the extracting sorbent. Prior to loading the water sample it was subjected to a simple derivatization procedure with 4-AAP. Method 2 showed high recognition ability/selectivity towards 2-CP-4-AAP with lower detection limit of 0.05 ng L−1 for 2-CP-4-AAP. Method 2 was able to detect the presence of 2-CP-4-AAP in unspiked real water samples and almost full spike recovery was achieved.  相似文献   

16.
A method has been developed to analyse for malachite green (MG), leucomalachite green (LMG), crystal violet (CV) and leucocrystal violet (LCV) residues in salmon. Salmon samples were extracted with acetonitrile:McIIIvain pH 3 buffer (90:10 v/v), sample extracts were purified on a Bakerbond strong cation exchange solid phase extraction cartridge. Aliquots of the extracts were analysed by LC-MS/MS. The method was validated in salmon, according to the criteria defined in Commission Decision 2002/657/EC. The decision limit (CCalpha) was 0.17, 0.15, 0.35 and 0.17 microg kg(-1), respectively, for MG, LMG, CV and LCV and for the detection capability (CCbeta) values of 0.30, 0.35, 0.80 and 0.32 microg kg(-1), respectively, were obtained. Fortifying salmon samples (n=6) in three separate assays, show the accuracy to be between 77 and 113% for MG, LMG, LCV and CV. The precision of the method, expressed as RSD values for the within-laboratory reproducibility, for MG, LMG and LCV at the three levels of fortification (1, 1.5 and 2.0 microg kg(-1)), was less than 13%. For CV a more variable precision was obtained, with RSD values ranging between 20 and 25%.  相似文献   

17.
The examination of the effect of interfering ions on the analytical signal of ruthenium measured by electrothermal atomic absorption spectrometry was initially performed in this work. The complexes of ruthenium(III) with thiosemicarbazide (TSd) and acetaldehyde thiosemicarbazone (AcTSn) were prepared and imprinted in polymeric network. The ion-imprinted polymers were synthesized by copolymerization of methacrylic acid, as functional monomer and ethylene glycol dimethacrylate, as crosslinking agent in the presence of 2,2-azobisisobutyronitrile as initiator. The effects of sample volume, pH, and flow rate on the extraction of analyte were studied in dynamic mode. The optimum pH for quantitative retention of ruthenium on each of the studied sorbents was 7.5 ± 0.5. The elution of analyte was completed with 0.2 mol L−1 thiourea in 0.2 mol L−1 HCl. The effect of matrix ions on ruthenium(III) separation process was studied. The analytical performance of the Ru-TSd polymer in the presence of competing ions was better than Ru-AcTSn polymer, considering recovery of analyte, reproducibility of results, selectivity coefficients, and sorbent capacity. The detection limit of the proposed method (0.16 ng mL−1 on Ru-TSd and 0.25 ng mL−1 on Ru-AcTSn) is lower in comparison with the previously published methods. The developed separation method was successfully applied to the determination of trace amounts of ruthenium in spiked water samples, sludge, grass, and human hair.  相似文献   

18.
Xi C  Liu Z  Kong L  Hu X  Liu S 《Analytica chimica acta》2008,613(1):83-90
In pH 4.2-4.8 HAc-NaAc buffer solution, folic acid (FA) could react with uranium (VI) to form a 2:1 anionic chelate which further reacted with some basic triphenylmethane dyes (BTPMD) such as Ethyl Violet (EV), Methyl Violet (MV) and Crystal Violet (CV) to form 1:2 ion-association complexes. As a result, not only the absorption spectra were changed, but also the intensities of resonance Rayleigh scattering (RRS) were enhanced greatly and the new RRS spectra were observed. The maximum RRS wavelengths were located at 328 nm for EV system, 325 nm for MV system and 328 nm for CV system. The fading degree (ΔA) and RRS intensities (ΔI) of three systems were different. Under given conditions, the ΔA and ΔI were all directly proportional to the concentration of FA. The linear ranges and the detection limits of RRS methods were 0.0039-5.0 μg mL−1 and 1.2 ng mL−1 for EV system, 0.0073-4.0 μg mL−1 and 2.2 ng mL−1 for MV system, 0.014-3.5 μg mL−1 and 4.7 ng mL−1 for CV system. The RRS methods exhibited higher sensitivity, so they are more suitable for the determination of trace FA. The optimum conditions, the influencing factors and the effects of coexisting substances on the reaction were investigated. The method can be applied to the determination of FA in serum and urine samples with satisfactory results. The structure of the ternary ion-association complex and the reaction mechanism were discussed in this work.  相似文献   

19.
Tso-Ying Chou 《Talanta》2009,80(2):493-9119
Partitioned dispersive liquid-liquid microextraction (PDLLME), using THF as the dispersive solvent and dichloromethane as the extraction solvent, was utilized to isolate and concentrate phenylurea herbicides (PUHs) from aqueous samples. In PDLLME, a dispersive solvent should be able to partition in the organic extractant droplets to effectively extract the polar organic compounds from aqueous samples. The mixture of the water-immiscible extractant and the partitioned dispersive solvent was obtained by centrifugation, dried under low pressure, reconstituted in methanol-water mixture (1:1), and injected into a HPLC system for the determination of PUHs. The enrichment factors of the PUHs ranged from 68 to 126 under the optimal conditions. The linear range was 0.5-100 ng ml−1 for each analyte, the relative standard deviations of PUHs were in the range of 1.5-5.9% (n = 5), and the detection limits (signal-to-noise ratio of 3) ranged from 0.10 to 0.28 ng ml−1 for the herbicides. The range of intraday precision (n = 5) for PUHs at the levels of 0.5, 5, and 50 ng ml−1 were 3.0-5.9%, 1.8-3.3%, and 2.2-3.6%, respectively. The range of interday precision (n = 5) at 0.5, 5, and 50 ng ml−1 were 0.4-1.8%, 1.2-2.4%, and 0.9-2.3%, respectively. The recoveries of PUHs from three spiked river water samples, at a level of 10 ng ml−1, were 91.2-104.1%. Due to its rapidity, ease of operation, and high recovery, PDLLME can be utilized to isolate and concentrate organic environmental contaminants such as PUHs from aqueous samples.  相似文献   

20.
A simple method based on magnetic separation for selective extraction of fluoroquinolones (FQs) from environmental water samples has been developed using magnetic molecularly imprinted polymer (MMIP) as sorbent. The MMIP has been prepared using ciprofloxacin as template molecule, methacrylic acid as functional monomer, ethylene glycol dimethacrylate as cross-linking agent and Fe3O4 magnetite as magnetic component. The polymer has been characterized by scanning electron microscopy, Fourier-transform infrared spectrometry and vibrating sample magnetometry. Various parameters affecting the extraction efficiency were evaluated in order to achieve optimal concentration and reduce non-specific interactions. The analytes desorbed from the polymers were determined by liquid chromatography-tandem mass spectrometry. The matrix effect was evaluated by using different washing solvents for removing interfering compounds from the MMIPs after sample loading. Under the optimal conditions, the linearity of the method obtained is in the range of 20-2000 ng L−1. The detection limits of FQs are in the range of 3.2-6.2 ng L−1. The relative standard deviations of intra- and inter-day tests ranging from 2.5 to 7.2% and from 3.6 to 9.1% are obtained. In all three spiked levels (20, 100 and 200 ng L−1), the recoveries of FQs are in the range of 76.3-94.2%. The proposed method was successfully applied to determine FQs including ciprofloxacin, enrofloxacin, lomefloxacin, levofloxacin, fleroxacin and sparfloxacin in different water samples, such as lake water, river water, primary and final sewage effluent. Ciprofloxacin and fleroxacin were found in primary and final sewage effluent samples with the contents in the range of 26-87 ng L−1.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号