1.
A new luminescent europium probe is presented for the determination of phosphate (P) in microtiter plate format. The assay is based on the quenching of the luminescence of the europium-tetracycline (EuTc) 1:1 complex by phosphate using a reagent concentration of 20.8 μmol/L. The probe is excited at 400 nm and displays a large Stokes’ shift of 210 nm. The emission maximum is located at 616 nm. The system works best at neutral pH 7 and is therefore suitable for phosphate determination in biological and biochemical systems. The linear range of the calibration plot is from 5 × 10−6 mol/L to 7.5 × 10−4 mol/L of phosphate, and the limit of detection is 3 μmol/L.  相似文献   

2.
A novel, simple, sensitive and precise spectrofluorimetric method was developed for measuring the melamine concentration in different milk batch samples. The method was based upon measuring the quenching of the luminescence intensity of the produced yellow colored ruthenium(II) carbonyl complex of the general formula [Ru(CO)2(L)] (where L = anion of tetradentate Schiff base). The Ru(II) complex exhibited characteristic luminescence band in the visible region. The remarkable quenching of the luminescence intensity of [Ru(CO)2(L)] complex by various concentrations of melamine was successfully used as a chemosensor for the assessment of melamine in different milk samples at λex = 400 nm and pH 7.4 in DMSO with a linear dynamic range 1.0 × 10−6 to 3.0 × 10−9 mol L−1 and lower detection limit (LOD) and quantification detection limit (QOD) of 3.3 × 10−10 and 1.0 × 10−9 mol L−1, respectively.  相似文献   

3.
This paper proposes a new automated spectrophotometric method for the simultaneous determination of phosphate and arsenate without pre-treatment, which is faster, simpler, less expensive and hazardous than other well-known methods used with water samples. Such method is based on the different kinetic characteristics of complex formation of phosphate and arsenate with ammonium molybdate. A flow system was used in order to achieve good mixing and to provide precise time control. All the measurements were performed at the isosbestic point wavelength (885 nm). Chemical variables were optimized by factorial design (ammonium molybdate 0.015 mol L−1, potassium antimony tartrate 1 × 10−4 mol L−1, and sulphuric acid 0.7 mol L−1). An appropriate linear range for both analytes (0.50-8.00 μmol L−1), good inter-day reproducibility (4.9% [P] and 3.3% [P + As]) and a sample throughput of 6 h−1 were obtained. The detection limits are 0.4 μmol L−1 P and 0.19 μmol L−1 [P + As] (3.3 Sy/x). The method was validated.  相似文献   

4.
A compact, reliable and low cost flow injection chemiluminescence system is described. The flow system consists of a set of solenoid micro-pumps that can dispense reproductive micro-volumes of solutions. The luminometer was based on a coiled cell constructed from polyethylene tubing that was sandwiched between two large area photodiodes. The whole equipment costs about US$ 750 and weights ca. 3 kg. Equipment performance was evaluated by measuring low concentrations of hydrogen peroxide by oxidation of luminol and for the determination of ammonium, based on its inhibition of the luminescence provided by the reaction of luminol and sodium hypochlorite. Linear responses were achieved within 1.0-80 μmol L−1 H2O2 and 0.6-60 μmol L−1 NH4+ with detection limits estimated as 400 nmol L−1 H2O2 and 60 nmol L−1 NH4+ at the 99.7% confidence level. Coefficients of variation were 1.0 and 1.8%, estimated for 20 μmol L−1 H2O2 and 15 μmol L−1 NH4+ (n = 20), respectively. Reagent consumption of 55 μg luminol, effluent volume of 950 μL per determination and sampling rate of 120 samples per hour were also achieved.  相似文献   

5.
Hu Z  Tong C 《Analytica chimica acta》2007,587(2):187-193
The fluorescence intensity of methylene blue (MB) quenched by DNA in the pH range of 6.5-8.0 was studied with synchronous fluorescence technology. A novel method for detecting single-stranded and double-stranded DNA was developed. The decreased fluorescence intensity at 664 nm is in proportion to the concentration of DNA in the range of 0.28-11.0 μmol L−1 for ctDNA, 0.14-8.25 μmol L−1 for thermally denatured ctDNA and 0.28-8.25 μmol L−1 for hsDNA. The detection limits (S/N = 3) are 0.11, 0.04 and 0.04 μmol L−1, respectively. The method is rapid, selective, and the reagents are lower toxic. It has been used for the determination of DNA in synthetic samples with good satisfaction. In addition, the interaction modes between MB and ctDNA and the mechanism of the fluorescence quenching were also discussed in detail. The experimental results from absorption spectra and fluorescence polarization indicate that the possible interaction modes between MB and DNA are the electrostatic binding and the intercalation binding.  相似文献   

6.
Dos Santos LB  Abate G  Masini JC 《Talanta》2005,68(2):165-170
Square wave voltammetry automated by sequential injection analysis was applied to determine the Freundlich adsorption coefficients for the adsorption of atrazine onto a clay rich soil. The detection limit in soil extracts was between 0.18 and 0.48 μmol L−1, depending on the medium used to prepare the extracts (0.010 mol L−1 KCl, CaCl2 or HNO3 and 0.0050 mol L−1 H2SO4), all of them conditioned in 40 mmol L−1 Britton-Robinson buffer at pH 2.0 in presence of 0.25 mol L−1 NaNO3. Also in soil extracts the linear dynamic range was between 1.16 and 18.5 μmol L−1 (0.25-4.0 μg mL−1), with a sampling frequency of 190 h−1. The Kf Freundlich adsorption coefficient was 3.8 ± 0.2 μmol1−1/n Ln kg−1 in medium of 0.010 mol L−1 KCl or CaCl2, but increased to 7.7 ± 0.1 and 9.0 ± 0.3 μmol1−1/n Ln kg−1 in 0.010 mol L−1 HNO3 and 0.0050 mol L−1 H2SO4, respectively. The increase of Kf was related to the decrease of pH from 6.4-6.7 in KCl and CaCl2 to 3.7-4.0 in presence of HNO3 or H2SO4, which favors protonation of atrazine, facilitating electrostatic attractions with negative charges of the clay components of the soil. The 1/n parameters were between 0.76 and 0.86, indicating that the isotherms are not linear, suggesting the occurrence of chemisorption at specific adsorption sites. No statistically significant differences were observed in comparison to the adsorption coefficients obtained by HPLC. The advantage of the proposed SI-SWV method is the great saving of reagent because it does not use organic solvent as in the case of HPLC (50% (v/v) acetonitrile in the mobile phase). Additionally the start up of SI-SWV is immediate (no column conditioning necessary) and the analysis time is only 19 s.  相似文献   

7.
Chung KH  Lee W  Cho YH  Choi GS  Lee CW 《Talanta》2005,65(2):389-395
The complexation of europium ion (Eu(III)) with a soil fulvic acid (FA) has been studied at pH 5 in 0.01 M NaClO4 by different experimental methods, i.e. synchronous fluorescence spectroscopy (SyFS) and time resolved laser-induced fluorescence spectroscopy (TRLFS). A series of SyFS quenching spectra was obtained by increasing the Eu(III) concentration and keeping the FA concentration constant. The emission spectra and fluorescence lifetimes of the Eu(III) bound to the FA were also measured by a TRLFS system using the same solution used in the SyFS spectral measurement. From the analysis of the fluorescence data obtained by the SyFS and the TRLFS using a non-linear least-squares method, the concentration of the binding sites (CL) of the FA accessible for the Eu(III) and the corresponding conditional stability constants (log K) were estimated. The two different methods gave rise to constants being comparable with one another. The log K and CL values (mean ± standard deviation of three determinations) determined by the SyFS were 6.4 ± 0.2 (6.7 ± 0.1 μmol L−1: by the TRLFS) and 10 ± 1 μmol L−1 (7 ± 1 μmol L−1: by the TRLFS), respectively. The applicability of the FA fluorescence quenching techniques for estimating the europium binding parameters was proved by the direct monitoring of the Eu(III) bound to the FA using the TRLFS system.  相似文献   

8.
A screen-printed amperometric biosensor based on carbon ink double bulk-modified with MnO2 as a mediator and glucose oxidase as a biocomponent was investigated for its ability to serve as a detector for bonded glucose in different compounds, such as cellobiose, saccharose, (-)-4-nitrophenyl-β-d-glucopyranoside, as well as in beer samples by flow-injection analysis (FIA). The biosensor could be operated under physiological conditions (0.1 M phosphate buffer, pH 7.5) and exhibited good reproducibility and stability. Bonded glucose was released with glucosidase in solution, and the free glucose was detected with the modified screen-printed electrode (SPE). The release of glucose by the aid of glucosidase from cellobiose, saccharose and (-)-4-nitrophenyl-β-d-glucopyranoside in solution showed that stoichiometric quantities of free glucose could be monitored in all three cases.The linear range of the amperometric response of the biosensor in the FIA-mode flow rate 0.2 mL min−1, injection volume 0.25 mL, operation potential 0.48 V versus Ag/AgCl) extends from 11 to 13,900 μmol L−1 glucose in free form. The limit of detection (3σ) is 1 μmol L−1 glucose. A concentration of 100 μmol L−1 yields a relative standard deviation of approximately 7% with five injections. These values correspond to the same concentrations of bonded glucose supposed that it is liberated quantitatively (incubation for 2 h with glucosidase).Bonded glucose could be determined in beer samples using the same assay. The results corresponded very well with the reference procedure.  相似文献   

9.
Liang Y  Liu XJ  Liu Y  Yu XY  Fan MT 《Analytica chimica acta》2008,615(2):174-183
A general and broad class-specific enzyme-linked immunosorbent assay was developed for the O,O-dimethyl organophosphorus pesticides, including malathion, dimethoate, phenthoate, phosmet, methidathion, fenitrothion, methyl parathion and fenthion. Three haptens with different spacer-arms were synthesized. The haptens were conjugated to bovine serum albumin (BSA) for immunogens and to ovalbumin (OVA) for coating antigens. Rabbits were immunized with the immunogens and six polyclonal antisera were produced and screened against each of the coating antigens using competitive indirect enzyme-linked immunosorbent assay for selecting the proper antiserum. The effect of hapten heterology on immunoassay sensitivity was also studied. The antibody-antigen combination with the most selectivity for malathion was further optimized and tested for tolerance to co-solvent, pH and ionic strength changes. The IC50 values, under optimum conditions, were estimated to be 30.1 μg L−1for malathion, 28.9 μg L−1 for dimethoate, 88.3 μg L−1 for phenthoate, 159.7 μg L−1 for phosmet, 191.7 μg L−1 for methidathion, 324.0 μg L−1 for fenitrothion, 483.9 μg L−1 for methyl parathion, and 788.9 μg L−1 for fenthion. Recoveries of malathion, dimethoate, phenthoate, phosmet and methidathion from fortified Chinese cabbage samples ranged between 77.1% and 104.7%. This assay can be used in monitoring studies for the multi-residue determination of O,O-dimethyl organophosphorus pesticides.  相似文献   

10.
H2O2 is a widely occurring molecule which is also a byproduct of a number of enzymatic reactions. It can therefore be used to quantify the corresponding enzymatic substrates. In this study, the time-resolved fluorescence emission of a previously described complex consisting of phthalic acid and terbium (III) ions (PATb) is used for H2O2 detection. In detail, glucose oxidase and choline oxidase convert glucose and choline, respectively, to generate H2O2 which acts as a quencher for the PATb complex. The response time of the PATb complex toward H2O2 is immediate and the assay time only depends on the conversion rate of the enzymes involved. The PATb assay quantifies glucose in a linear range of 0.02–10 mmol L−1, and choline from 1.56 to 100 μmol L−1 with a detection limit of 20 μmol L−1 for glucose and 1.56 μmol L−1 for choline. Both biomolecules glucose and choline could be detected without pretreatment with good precision and reproducibility in human serum samples and infant formula, respectively. Furthermore, it is shown that the detected glucose concentrations by the PATb system agree with the results of a commercially available assay. In principle, the PATb system is a universal and versatile tool for the quantification of any substrate and enzyme reaction where H2O2 is involved.  相似文献   

11.
A direct method for the determination of citrate and oxytetracycline in samples containing complex matrices like tablets or serum has been developed using the luminescence of the ternary complex formed with Eu(III) ions. The triplet-state energy level of oxytetracycline (OxTc), the excitation maximum (412 nm) and the luminescence lifetime of Eu-OxTc (58 μs) were determined. A 17-fold luminescence enhancement at 615 nm occurs upon addition of citrate within a short 5-min incubation time at neutral pH. This is accompanied by a threefold increase of the luminescence decay time. The optimal conditions for determination of OxTc are equal concentrations of Eu (III) and citrate (C = 1 · 10− 4 mol L− 1) and pH 7.2. For determination of citrate, the optimal concentrations of Eu(III) and OxTc are 1 : 0.5 (CEu = 1 · 10− 4 mol L− 1, COxTc = 5 · 10− 5 mol L− 1) at pH 7.2. The linear range for determination of OxTc in serum is 0.25-250 μg mL− 1, and for citrate in tablets from 0.5 to 10.0 μg mL− 1 (2.3 · 10− 6- 4 · 10− 5 mol L− 1). The detection limit was 0.1 μg mL− 1 for OxTc and 0.2 μg mL− 1 (1 · 10-6 mol L− 1) for citrate, respectively. A comparison of the new method with other methods for determination of citrate is given.  相似文献   

12.
Navid Nasirizadeh 《Talanta》2009,80(2):656-661
A highly efficient noradrenalin (NA) biosensor was fabricated on the basis of hematoxylin electrodeposited on a glassy carbon electrode, GCE. The cyclic voltammetric responses of the hematoxylin biosensor at various scan rates, which were obtained in a 0.25 mmol L−1 NA solution, showed the characteristic shape typical of an ECcat process. The kinetic parameters such as electron transfer coefficient, α, the catalytic electron transfer rate constant, k′, and the standard catalytic electron transfer rate constant, k0, for oxidation of NA at the hematoxylin biosensor surface were estimated using cyclic and RDE voltammetry. The peaks of differential pulse voltammetric (DPV) for NA and acetaminophen (AC) oxidation at the hematoxylin biosensor surface were clearly separated from each other when they co-exited in the physiological pH (pH 7.0). It was, therefore, possible to simultaneously determine NA and AC in the samples at a hematoxylin biosensor. Linear calibration curves were obtained for 5.0 × 10−1 to 65.40 μmol L−1 and 65.40-274.20 μmol L−1 of NA, and for 12.00-59.10 μmol L−1 and 59.10-261.70 μmol L−1 of AC. The sensitivities of the biosensor to NA in the absence and presence of AC were found virtually the same, which indicates the fact that the electrocatalytic oxidation processes of NA are independent of AC and, therefore, simultaneous or independent measurements of the two analytes (NA and AC) are possible without any interference. The results of 16 successive measurements show an average voltammetric peak current of 1.13 ± 0.03 μA for an electrolyte solution containing 5.00 μmol L−1 NA. The hematoxylin biosensor has been satisfactorily used for the determination of NA and AC in pharmaceutical formulations. The results obtained, using the biosensor, are in very good agreement with those declared in the label of pharmaceutical inhalation products.  相似文献   

13.
A simple and sensitive spectrophotometric flow method for determination of low concentrations of the flotation collector O-ethyldithiocarbonate (ethyl xanthate, CH3CH2-O-CS2) in solutions is described. The method is based on ethyl xanthate detection at 301 nm in medium of NaOH 50 mmol L−1. By injection of 200 μL of sample, the analytical method shows linear response for the ethyl xanthate concentration from 0.5 up to 500 μmol L−1. Successive injections of 4 μmol L−1 ethyl xanthate (n = 23) show a coefficient of variation lower than 0.6%, denoting high repeatability. The detection limit is 0.3 μmol L−1. At a flow rate of 2.0 mL min−1, a frequency of 120 injections/h of ethyl xanthate can be attained. By introduction of a tangential dialysis cell in the FIA system, the manual sample filtration step with 0.22 μm filter was eliminated and the residual interference of suspended material, was completely overcome even for unfiltered sludge suspension samples, an important advantage that compensates for the frequency reduction to 25 injections/h elevation and detection limit elevation to 2 μmol L−1, still outreaching for many applications. Potential applications of the method embrace the at line determination of ethyl xanthate in the ore processing industry, control of the concentration at its optimal level during the flotation process, as well as monitoring of residues in the effluents.  相似文献   

14.
Under the conditions of 0.04 mol L−1 HCl-8.0 × 10−4 mol L−1 KI, there is a fluorescence peak at 540 nm and a synchronous fluorescence peak at 540 nm for rhodamine 6G (RhG). When there is IO3, it reacts with exceed I to form I3. And I3 and RhG combine into ion association particles. The particles exhibit three resonance scattering peaks at 320, 400 and 595 nm. And there is fluorescence quenching at 540 nm. Iodine concentration is proportional to the intensity of the resonance scattering intensity at 400 nm in the range of 1.0-20 × 10−7 mol L−1. And a new resonance scattering spectral (RSS) method has been described for the determination of IO3 in salt samples. The spectral results have been verified that the formation of (RhG-I3)n association particles and solid-liquid interfaces are the main factor that cause the fluorescence quenching and resonance scattering effects.  相似文献   

15.
A fast, sensitive and selective method for the determination of aluminium based on the reaction of the metal with pyrogallol red (PR) in the presence of tetrabutylammonium tetrafluoroborate (TBATFB) to form an Al(PR)3x9TBATFB complex which is adsorbed on the mercury electrode is presented. Under these conditions complexation of aluminium is rapid and no waiting period or heating of the sample is required. The reduction current of the accumulated complex is measured by scanning the potential in the cathodic direction. The variation of peak current with pH, adsorption time, adsorption potential, ligand and quaternary ammonium salt concentration, and some instrumental parameters, such as stirring rate in the accumulation stage, and step amplitude, pulse amplitude and step duration while obtaining the square wave voltamperograms were optimized. The best experimental parameters were pH 8.5, (NH4Ac-NH3 buffer), CPR = 25 μmol L−1, CTBATFB over 75 μmol L−1, tads = 60 s, and Eads = −0.60 V versus Ag/AgCl. A linear response is observed over the 0.0-30.0 μg L−1 concentration range, with a detection limit of 1.0 μg L−1. Reproducibility for 9.0 μg L−1 aluminium solution was 2.3% (n = 6). Synthetic sea water and sea water reference material CRM-SW were used for validation measurements. Aluminium in urine samples of a volunteer who ingested 800 mg of Al(OH)3 was analyzed.  相似文献   

16.
A novel biomimetic sensor for rutin determination based on a dinuclear complex [MnIIIMnII(Ldtb)(μ-OAc)2]BPh4 containing an unsymmetrical dinucleating ligand, 2-[N,N-bis(2-pyridylmethyl)-aminomethyl]-6-[N-(3,5-di-tert-butyl-2-oxidoben-zyl)-N-(2-pyridylamino)aminomethyl]-4-methylphenol (H2Ldtb), as a manganese peroxidase mimetic was developed. Several parameters were investigated to evaluate the performance of the biomimetic sensor obtained after the incorporation of the dinuclear complex in a carbon paste. The best performance was obtained in 75:15:10% (w/w/w) of the graphite powder:Nujol:MnIIIMnII complex, 0.1 mol L−1 phosphate buffer solution (pH 6.0) and 4.0 × 10−5 mol L−1 hydrogen peroxide. The response of the sensor towards rutin concentration was linear using square wave voltammetry in the range of 9.99 × 10−7 to 6.54 × 10−5 mol L−1 (r = 0.9998) with a detection limit of 1.75 × 10−7 mol L−1. The recovery study performed with pharmaceuticals ranged from 96.6% to 103.2% and the relative standard deviation was 1.85% for a solution containing 1.0 × 10−3 mol L−1 rutin (n = 6). The lifetime of this biomimetic sensor was 200 days (at least 750 determinations). The results obtained for rutin in pharmaceuticals using the biomimetic sensor and those obtained with the official method are in agreement at the 95% confidence level.  相似文献   

17.
The concept of sequential injection chromatography (SIC) was exploited to automate the fluorimetric determination of amino acids after pre-column derivatization with o-phthaldialdehyde (OPA) in presence of 2-mercaptoethanol (2MCE) using a reverse phase monolithic C18 stationary phase. The method is low-priced and based on five steps of isocratic elutions. The first step employs the mixture methanol: tetrahydrofuran: 10 mmol L−1 phosphate buffer (pH 7.2) at the volumetric ratio of 8:1:91; the other steps use methanol: 10 mmol L−1 phosphate buffer (pH 7.2) at volumetric ratios of 20:80, 35:65, 50:50 and 65:35. At a flow rate of 10 μL s−1 a 25 mm long-column was able to separate aspartic acid (Asp), glutamic acid (Glu), asparagine (Asn), serine (Ser), glutamine (Gln), glycine (Gly), threonine (Thr), citruline (Ctr), arginine (Arg), alanine (Ala), tyrosine (Tyr), phenylalanine (Phe), ornithine (Orn) and lysine (Lys) with resolution >1.2 as well as methionine (Met) and valine (Val) with resolution of 0.6. Under these conditions isoleucine (Ile) and leucine (Leu) co-eluted. The entire cycle of amino acids derivatization, chromatographic separation and column conditioning at the end of separation lasted 25 min. At a flow rate of 40 μL s−1 such time was reduced to 10 min at the cost of resolution worsening for the pairs Ctr/Arg and Orn/Lys. The detection limits varied from 0.092 μmol L−1 for Tyr to 0.51 μmol L−1 for Orn. The method was successfully applied to the determination of intracellular free amino acids in the green alga Tetraselmis gracilis during a period of seven days of cultivation. Samples spiked with known amounts of amino acids resulted in recoveries between 94 and 112%.  相似文献   

18.
Pyrolytic graphite electrodes (PGE) were modified into dopamine solutions using phosphate buffer solutions, pH 10 and 6.5, as supporting electrolyte. The modification process involved a previous anodization of the working electrode at +1.5 V into 0.1 mol L−1 NaOH followed by other anodization step, in the same experimental conditions, into dopamine (DA) solutions. pH of the supporting electrolyte performed an important role in the production of a superficial melanin polymeric film, which permitted the simultaneous detection of ascorbic acid (AA), (DA) and uric acid (UA), ΔEAA-DA = 222 mV; ΔEAA-UA = 360 mV and ΔEDA-UA = 138 mV, avoiding the superficial poisoning effects. The calculated detection limits were: 1.4 × 10−6 mol L−1 for uric acid, 1.3 × 10−5 mol L−1 for ascorbic acid and 1.1 × 10−7 mol L−1 for dopamine, with sensitivities of (7.7 ± 0.5), (0.061 ± 0.001) and (9.5 ± 0.05) A mol−1 cm−2, respectively, with no mutual interference. Uric acid was determined in urine, blood and serum human samples after dilution in phosphate buffer and no additional sample pre-treatment was necessary. The concentration of uric acid in urine was higher than the values found in blood and serum and the recovery tests (92-102%) indicated that no matrix effects were observed.  相似文献   

19.
A new heterodinuclear Fe(III)Zn(II) complex which mimics the active site of the hydrolytic enzyme red kidney bean purple acid phosphatase was synthesized and characterized by IR, CHN and X-ray crystallographic analyses. This complex, [FeIIIZnII(μ-OH)bpbpmp-CH3](ClO4)2, containing the ligand (H2bpbpmp-CH3 = {2-[bis(2-pyridylmethyl)aminomethyl]-6-[(2-hydroxy-5-methylbenzyl) (2-pyridyl-methyl) aminomethyl]-4-methyl-phenol}) was employed in the construction of a biomimetic sensor and used in the determination of rosmarinic acid in plant extract samples. The response parameters and optimization of the biomimetic sensor design were evaluated. The best performance of this sensor was obtained for 75:15:10% (w/w/w) of the graphite powder:nujol:Fe(III)Zn(II) complex, 0.1 mol L−1 phosphate buffer solution (pH 7.5), 1.19 × 10−4 mol L−1 hydrogen peroxide with frequency, pulse amplitude, and scan increment at 30 Hz, 100 mV, and 0.6 mV, respectively. The rosmarinic acid concentration was linear in the range of 2.98 × 10−5 to 3.83 × 10−4 mol L−1 (r = 0.9991) with a detection limit of 2.30 × 10−6 mol L−1. This biomimetic sensor demonstrated long-term stability (300 days; 900 determinations) and reproducibility, with a relative standard deviation of 12.0%. The recovery study of rosmarinic acid in plant extract samples gave values from 90.3 to 98.3% and the concentrations determined showed agreement when compared with those obtained using capillary electrophoresis at the 95% confidence level.  相似文献   

20.
Liu C  Mo YY  Chen ZG  Li X  Li OL  Zhou X 《Analytica chimica acta》2008,621(2):171-177
A new dual detection system for microchip is reported. Both fluorescence detector (FD) and contactless conductivity detector (CCD) were combined together and integrated on a microfluidic chip. They shared a common detection position and responded simultaneously. A blue light-emitting diode was used as excitation source and a small planar photodiode was used to collect the emitted fluorescence in fluorescence detection, which made the device more compact and portable. The coupling of the fluorescence and contactless conductivity modes at the same position of a single separation channel enhanced the detection characterization of sample and offered simultaneous detection information of both fluorescent and charged specimen. The detection conditions of the system were optimized. K+, Na+, fluorescein sodium, fluorescein isothiocyanate (FITC) and FITC-labeled amino acids were used to evaluate the performance of the dual detection system. The limits of detection (LOD) of FD for fluorescein Na+, FITC, FITC-labeled arginine (Arg), glycine (Gly) and phenylalanine (Phe) were 0.02 μmol L−1, 0.05 μmol L−1, 0.16 μmol L−1, 0.15 μmol L−1, 0.12 μmol L−1 respectively, and the limits of detection (LOD) of CCD achieved 0.58 μmol L−1 and 0.39 μmol L−1 for K+ and Na+ respectively.  相似文献   