相似文献
 共查询到20条相似文献,搜索用时 281 毫秒
1.
The recent findings of antibiotic residues in aquatic environment at trace level have gained much concern for the detrimental effect on ecological and human health due to bacterial resistance. Here, the feasibility of using electrospray ionization ion mobility spectrometry (ESI-IMS) for analysis antibiotics in liquid sample is demonstrated. Reduced mobilities and collision cross sections of 18 antibiotics are experimentally measured and compared with theoretical values according to mass-mobility correlation. Gentamicin is used as an example to investigate the capability of ESI-IMS for multi-component analysis of antibiotics. Mixtures of antibiotics at different concentrations are analyzed. The estimated detection limit for amoxicillin is 0.7 mg L−1 (70 pg) and the linear range of response maintains over two orders. This method will be a potential technique for the analysis of antibiotics in aquatic environment.  相似文献   

2.
B. Rezaei  R. Khademi 《Talanta》2009,79(3):669-675
Application of electrospray ionization ion mobility spectrometry (ESI-IMS) as the detection technique for separation method based on molecular imprinted polymer (MIP) was investigated and evaluated. The method is exhaustively validated, including sensitivity, selectivity, recovery, reproducibility, and column capacity. The linear dynamic range of 0.02-2.00 μg mL−1 was obtained for primidone analysis with ESI-IMS. The recovery of drug analyzed was calculated to be above 90% and the relative standard deviation (RSD), was below 3% for all experiments. Various real samples were analyzed with the coupled techniques, and the results obtained revealed the efficient clean-up of the samples using MIP separation before the analysis by ESI-IMS as a detection technique.  相似文献   

3.
Polycyclic aromatic hydrocarbons (PAHs) were analyzed as adsorbates on borosilicate glass at levels from 40 pg (5.5 pg mm−2) to 7 μg (1 μg mm−2) using laser desorption-ionization (LDI) in air at ambient pressure and 100 °C with ion characterization by mobility spectrometry. Gas-phase positive ions with distinctive mobilities were produced from six PAHs using an unfocused beam at 266 nm, 6 mJ pulse−1 and 10 Hz from a Nd-YAG laser. The ions produced were identified as M+ using mass spectrometry (MS) with a LDI source at atmospheric pressure. The mobility spectrometry drift tube provided low memory effects and allowed observation of time-resolved intensity profiles for ion signals, and changes in this behavior with loading level suggested intermolecular interactions from multilayer formation. Mobility peaks were broader than those seen in gas-phase reactions, and this was attributed to Coulombic repulsion caused by the small volume near the surface where ionization would take place. An ion shutter in the drift tube could be synchronized with the laser pulse to offer additional specificity using tandem mobility separation; further, resolution was improved in mixtures of PAHs with similar mobilities. Negative ions were also detected, though these were mass-identified as ions formed from air through the capture of electrons released from the PAHs; no M-ions were observed in air. Limits of detection ranged from sub-pg to low-ng for individual PAHs.  相似文献   

4.
Rezaei B  Jafari MT  Rahmanian O 《Talanta》2011,83(3):765-769
In this research, selective separation and determination of phenazopyridine (PAP) is demonstrated using molecular imprinted polymer (MIP) coupled with electrospray ionization ion mobility spectrometry (ESI-IMS). In the non-covalent approach, selective MIP produced using PAP and methacrylic acid (MAA) as a template molecule and monomer, respectively. The created polymer is utilized as a media for solid-phase extraction (SPE), revealing selective binding properties for the analyte from pharmaceutical and serum samples. A coupled MIP-IMS makes it possible to quantitize PAP in the range of 1-100 ng mL−1 and with a 0.2 ng mL−1 detection limit. Furthermore, the MIP selectivity is evaluated by application of some substances with analogous and different molecular structures to that of PAP. This method is successfully applied for the determination of PAP in pharmaceutical and serum samples.  相似文献   

5.
Separation of amino acids by ion mobility spectrometry   总被引:1,自引:0,他引:1  
The mobilities of the 20 common amino acids were determined by electrospray ionization ion mobility spectrometry. It was found that each amino acid had a different drift time and hence a different reduced mobility constant K0. This difference in drift time was less than 0.1 ms in many cases. With the instrument used in this study it would not be possible to resolve mixtures of some of the amino acids. It would however be possible to determine any single amino acid. In addition, the detection limits were determined for the 20 amino acids. They ranged from 50 to 700 pg. This indicates that the detection limits were less than 3 pmol for all of the amino acids and that many amino acids had detection limits less than 1 pmol.  相似文献   

6.
Dion HM  Ackerman LK  Hill HH 《Talanta》2002,57(6):1161-1171
The results from this study illustrate the first time electrospray ionization-ion mobility spectrometry (ESI-IMS) has been used to separate inorganic cations in aqueous solutions. Using ESI-IMS nine inorganic cation solutions were analyzed. Counter ions affected both the sensitivity and the identity of the response ions. Aluminum sulfate, lanthanum chloride, strontium chloride, uranyl acetate, uranyl nitrate, and zinc sulfate produced spectra containing a single response ion. Aluminum nitrate and zinc acetate solutions produced multiple ion peaks, which increased the detection limits and the difficulty of identification. Cation detection limits ranged from 0.16 to 13 ng μl−1 depending on the solution studied. The identities of the ion species detected were unconfirmed, but mass spectrometry literature suggested the detection of positively charged cation-solvent or cation-solvent-anion complexes. Finally, cations from strontium and lanthanum chloride solutions were separated with a resolution of 2.2. The results from this study suggest that ESI-IMS has potential as a field technique for the detection of metal cations and their complexes in the environment.  相似文献   

7.
Dwivedi P  Matz LM  Atkinson DA  Hill HH 《The Analyst》2004,129(2):139-144
This paper reports the first example of electrospray ionization (ESI) for the separation and detection of anions in aqueous solutions by ion mobility spectrometry (IMS). Standard solutions of arsenate, phosphate, sulfate, nitrate, nitrite, chloride, formate, and acetate were analyzed using ESI-IMS and distinct peak patterns and reduced mobility constants (K(0)) were observed for respective anions. Real world water samples were analyzed for nitrate and nitrite to determine the feasibility of using ESI-IMS as a rapid analytical method for monitoring nitrate and nitrite in water systems. The data showed satisfactory correlation between the measured value ([similar]0.16 ppm) and the reported maximum nitrate-nitrogen concentration (0.2 ppm) found in a local drinking water system. For on-site measurement applications, direct sample introduction and air as an alternate drift gas to nitrogen were evaluated. The identities of the nitrite and nitrate mobility peaks were verified by comparison of reduced mobility constants with mass identified nitrate and nitrite ions reported in literature. In the mixing ratio, a linear dynamic range of 3 orders of magnitude and instrument detection limits of 10 ppb for nitrate and 40 ppb for nitrite were obtained. The calibration curves showed r(2) value of 0.98 and slope of 0.06 for nitrate and r(2) value of 0.99 and slope of 0.11 for nitrite.  相似文献   

8.
Atmospheric humidity causes the major problem using ion mobility spectrometers (IMS) under ambient conditions. Significant changes of the spectra are decreasing sensitivity as well as selectivity. Therefore, the influence of humidity on the IMS signal was investigated in case of direct introduction of the analyte into the ionisation chamber and in case of pre-separation by help of a multi-capillary column (MCC). For direct analyte introduction, a significant decrease of the total number of ions in the range of 28-42% with increasing relative humidity was found. Simultaneously additional peaks in the spectra were formed, thus complicating the identification of the analytes. In case of pre-separation of the analyte, the spectra do not change with increasing relative humidity, due to the successive appearance of the analyte and the water molecules in the ionisation chamber. Detection limits were found in the range of 5 μg/m3 (about 1 ppbv) for selected terpenes and—with pre-separation—independent on relative humidity of the analyte. Without pre-separation, detection limits are in the same range for dry air as carrier gas but in the range of 200-600 μg/m3 when relative humidity reaches 100%. Thus, MCC-UV ion mobility spectrometry is optimally capable for the detection of trace substances in ambient air (e.g. indoor air quality control, process control, odour detection) without further elaborate treatment of the carrier gas containing the analyte and independent on relative humidity.  相似文献   

9.
Gas phase ions for valine, glutamate, phenylalanine, angiotensin, bradykinin, LH-RH, and bombesin were formed through matrix assisted laser desorption-ionization (MALDI) in air at ambient pressure and were characterized by ion mobility spectrometry (IMS). The IMS drift tube was operated at 100 °C with air as the drift gas and without an ion shutter. Responses were obtained using α-cyano-4-hydroxycinnamic acid as the matrix and a Nd-YAG laser at 355 nm with an unfocused beam at 6 mJ per pulse and 7 mm2 cross section. Matrix and analyte were applied to a borosilicate glass target and microgram amounts of sample provided responses lasting 10 to 15 s with the laser operated at 11 Hz. Detection limits for the peptides were estimated to be 10 to 100 pmol per laser shot. The mobility spectra for individual amino acids and peptides exhibited multiple peaks with spectral distortions and raised baselines. These features and calculated values for reduced mobilities were consistent with the existence of clusters between analyte ions and matrix neutrals and the dissociation of these clusters in the drift region of the analyzer. Mobility spectra with distinctive peaks were not obtained for MALDI-IMS of peptides larger than 5700 amu, though ion formation was suggested from the depletion of matrix signal.  相似文献   

10.
A high-field asymmetric waveform ion mobility spectrometry (FAIMS)-based method for the determination of the mycotoxin zearalenone (ZON) and its metabolites α-zearalenol (α-ZOL), β-zearalenol (β-ZOL), and β-zearalanol (β-ZAL), in a cornmeal (maize) matrix is described. Detection limits achieved using the FAIMS device coupled with electrospray ionization (ESI) and mass spectrometric (MS) detection are 0.4 ng mL−1 for ZON and 3 ng mL−1 for α-ZOL + β-ZOL, and β-ZAL. This represents a significant improvement when compared to detection limits determined using ESI-MS or ESI-tandem mass spectrometry (MSMS) analytical methods. The developed flow-injection (FIA)-ESI-FAIMS-MS method was applied to reference materials ERM-BC-716 and ERM-BC-717 certified for ZON and excellent agreement with the certified values was observed.  相似文献   

11.
The present study describes a new environmentally friendly sample pretreatment system based on solid-phase microextraction (SPME) for the sensitive determination of polyphenols. A derivatization process was necessary to convert the polar non-volatile compounds into volatile derivatives. Direct immersion (DI) SPME was used for the adsorption of polyphenols, and then the fiber was placed in the headspace of the derivatizing reagent, bis(trimethylsilyl)trifluoroacetamide (BSTFA). The separation was carried out by coupling gas chromatography with mass spectrometry in the selected ion monitoring mode, after silylation. Optimal extraction conditions were 25 °C for 10 min under continuous stirring using DI and a polyacrylate fiber. After extraction, the fiber was inserted into the headspace of BSTFA (10 μL) and the polyphenols were derivatized for 15 min at 50 °C. Desorption was carried out at 280 °C for 5 min. The method allowed the determination of both isomers cis- and trans-resveratrol, piceatannol, catechin and epicatechin in wine and grapes, and it was validated for linearity, detection and quantitation limits, selectivity, accuracy and precision. Detection limits ranged from 0.05 to 0.9 ng mL−1 at a signal-to-noise ratio of 3, depending on the compound. Recoveries obtained for spiked samples were satisfactory for all compounds.  相似文献   

12.
A fast separation of alkali and alkaline earth metal cations and ammonium was carried out by capillary electrochromatography on monolithic octadecylsilica columns of 15 cm length and 100 μm inner diameter using water/methanol mixtures containing acetic acid as mobile phase. On-column contactless conductivity detection was used for quantification of these non-UV-absorbing species. The method was also extended successfully to the determination of small amines as well as of amino acids, and the separation selectivity was optimized by varying the composition of the mobile phase. Detection limits of about 1 μM were possible for the inorganic cations as well as for the small amines, while the amino acids could be quantified down to about 10 μM. The separation of 12 amino acids was achieved in the relatively short time of 10 min.  相似文献   

13.
Two new approaches to reduce false positive interferences commonly observed with explosives and drugs detection in the field were reported for ion mobility spectrometry (IMS). One of the approaches involved the rapid preseparation of potential interferences prior to detection by IMS. Firstly, it was found that the introduction of a short column packed with adsorption packing material before an IMS could help to reduce the false positive rates. Secondly, the retention time at which the most intense response occurred over the analysis time period could be utilized to separate false positive responses from target analytes with the same drift times. Rapid preseparation of potential interferences provided a greater degree of confidence for the detection (in less than 30 s) of drugs, explosives and chemical warfare agents (CWAs). Detection limits as low as 10 pg of TNT with a sensitivity of 12 A g−1 were reported. Successful development of this technique may lead to the construction of a simple interface fitted with a short column of adsorption packing material to enhance either initial separation or to hold-back interferences mixed with explosive and drug responses in the field.  相似文献   

14.
A method for the determination of 16 polycyclic aromatic hydrocarbons (PAHs) in milk and related products based on direct immersion-solid phase microextraction (DI-SPME) followed by gas chromatography-mass spectrometry detection (GC-MS) has been developed. The influence of various parameters on PAH extraction efficiency was carefully monitored. Good performance (recovery, precision and quantitation limits) was attained when a PDMS/DVB fiber was immersed in the sample for 60 min at 55 °C. Detection limits ranged from 0.003 to 1.5 μg L−1 at a signal-to-noise ratio of 3, depending on the compound and the sample. The proposed method was successfully applied to infant formulas, milk and related products and the presence of both fluoranthene and pyrene in two samples was confirmed.  相似文献   

15.
In this work, a water-soluble polymer, polyethylenimine (PEI) was used for the simultaneous separation and preconcentration of trace Cu and Mn prior to their determination by flame atomic absorption spectrometry. For this purpose, the sample and the PEI solution were mixed and the metal-bound polymer was precipitated by adding acetone. The precipitate was separated and dissolved in a minimum amounts of water and aspirated into a flame AAS. By increasing the ratio of the volumes of sample to water used in dissolving the precipitate, the analyte elements were concentrated as needed. The sorption is quantitative in the pH ≥6. Detection limits were 5.2 μg/L for Cu and 5.4 μg/L for Mn. This method is simple, fast and precise.  相似文献   

16.
A practical analytical methodology based on coupling microwave-assisted extraction-stir bar sorptive extraction-thermal desorption-gas chromatography-mass spectrometry (MAE-SBSE-TD-GC-MS) was developed and validated for the characterization of several SVOC in atmospheric particulate matter (PM).The high enrichment capacity of SBSE makes it a powerful tool for improving detection limits and MAE has been useful for overcoming the long extraction times and high volumes of extraction solvent used in traditional methodologies. Relative to Soxhlet extraction followed by GC-MS analysis (EPA Methods 3540 and 8270C), the MAE-SBSE-TD-GC-MS methodology resulted with approximately 104 times better detection limits. Detection limits ranged from 0.3 to 8.3 pg m−3 for pp′-DDD and decachlorobyphenyl, respectively in PM2.5, 24 m3 air sample. The performance of the optimized methodology gave good precisions, with R.S.D. less than 30% for most of the standards, and linearity within the range tested of 0.1-15 μg L−1. Analysis of real PM samples resulted in the identification of compounds in the ng L−1 range.  相似文献   

17.
Jana Olšovská 《Talanta》2010,80(5):1849-1147
A new ultra high-performance liquid chromatography method with UV detection was examined for detection and separation of polychlorinated biphenyls. This included optimization of separation conditions for two model mixtures containing seven and fifteen most relevant congeners, comparison of three types of reversed phase sub-2-micron particle sized columns and assessment of system suitability under the optimized conditions. Calibration curves determined in the range from 0.5 to 50.0 μg/mL exhibited correlation coefficients ranging from 0.997 to 0.999. Lower limits of detection ranged from 0.1 to 0.5 ppm. The most efficient Grace C18 column filled with 1.5 μm particles was then tested to separate the complex commercial mixture Delor 103, where the elution order was confirmed by GC-MS. 13 individual congeners were separated and some of the other co-eluting congeners could be resolved using another separation dimension performed with a mass spectrometry detector. The developed method could be directly applied to the separation of less complex mixtures in aqueous sample matrixes, which are used in general for enzyme degradation studies.  相似文献   

18.
A rapid and solvent-free method for the determination of eight volatile organic sulphur and two selenium compounds in different beverage samples using headspace solid-phase microextraction and gas chromatography with atomic emission detection has been developed. The bonded carboxen/polydimethylsiloxane fiber was the most suitable for preconcentrating the analytes from the headspace of the sample solution. Volumes of 20 mL of undiluted beer were used while, in the case of wines and spirits, sample:water ratios of 5:15 and 2:18, respectively, were used, in order to obtain the maximum sensitivity. Quantitation was carried out by using synthetic matrices of beer and wine, and a spiked sample for spirits, and using ethyl methyl sulphide and isopropyl disulphide as internal standards. Detection limits ranged from 8 ng L−1 to 40 ng mL−1, depending on the compound and the beverage sample analyzed, with a fiber time exposure of 20 min at ambient temperature. The optimized method was successfully applied to different samples, some of the studied compounds being detected at concentration levels in the 0.04–152 ng mL−1 range.  相似文献   

19.
The comparison of nanospray and microspray ionizations for detecting mixtures of compounds by ion mobility spectrometry has been investigated for sensitivity, ion transmission through a drift tube, and ion suppression effects when used as an ionization source for ambient pressure ion mobility spectrometry (IMS). Several articles have demonstrated that nano-electrospray ionization mass spectrometry (n-ESI-MS) has improved sensitivity, provides less background noise, and lower limits of detection than micro-electrospray ionization (μ-ESI) for IMS. Most importantly, data from n-ESI-MS is concentration-sensitive. Our laboratory previously published an article that observed a striking result when μ-ESI-IMS was investigated for a single compound in the positive ion mode. The data reported was mass-sensitive. In this new investigation, we have investigated mixtures, and experiments were designed to evaluate the effect of sensitivity, ion transmission and ion suppressions in μ-ESI-IMS and n-ESI-IMS. At an electrospray flow rate in the μL min−1 range, compounds with higher proton affinities responded best while at the nanospray flow rates of nL min−1, relative responses were more equal. This study observed that a decreased ESI flow rate resulted in a decreased ion signal. These trends demonstrated less sensitivity for ESI-IMS at reduced flow rates but suggest better quantification. At higher flow rates, relative ionization efficiencies were still uniform for all the components studied individually and in mixtures and sensitivity improved by about 78%. Concentration studies showed that at high concentrations, ion detection efficiencies were uniform at about 33% for all compounds studied individually and in mixtures. At low concentrations, the detection efficiency varied from 31% to 86%, depending on the proton affinity of the component in the mixture. Ion transmission through the IMS tube measured with a segmented Faraday detector that was incorporated into the IMS design indicated that most of the ion current for mixtures was transported through the IMS tube with a radius of less than 18 mm for both positive and negative ion modes.  相似文献   

20.
This paper explains the effect of pressure on separation factor, resolving power (defined based on a single peak), and resolution (defined based on two adjacent peaks) in ion mobility spectrometry. IMS spectra were recorded at various pressures ranging from 39 hPa (29 Torr) up to atmospheric pressure and various ion gates ranging from 50 to 225 μs. The results show that the IMS peaks shift perfectly linear with pressure so that separation factors remain unaffected by pressure. However, pressure has strong influence on resolving power and resolution. Reducing pressure at constant pulse width decreases the resolving power and resolution. On the other hand, the decrease in resolution can be compensated by shortening the ion pulse width since reducing pressure results in a higher ion current.  相似文献   