首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 937 毫秒
1.
Luminescent semiconductor quantum dot (QD)-based optical biosensors have the potential to overcome many of the limitations associated with using conventional organic dyes for biodetection. We have previously demonstrated a hybrid QD-protein-based fluorescence resonance energy transfer (FRET) sensor. Although the QD acted as an energy donor and a protein scaffold in the sensor, recognition and specificity were derived from the proteins. Transitioning this hybrid prototype sensor into flow cells and integrated devices will require a surface-immobilization strategy that allows the QD-based sensor to sample the environment and still maintain a distinct protein-covered QD architecture. We demonstrate a self-assembled strategy designed to accomplish this. Using glass slides coated with a monolayer of neutravidin (NA) as the template, QDs with maltose binding protein (MBP) and avidin coordinated to their surface were attached to the glass slides in discrete patterns using an intermediary bridge of biotinylated MBP or antibody linkers. Control of the surface location and concentration of the QD-protein-based structures is demonstrated. The utility of this self-assembly strategy is further demonstrated by assembling a QD-protein structure that allows the QDs to engage in FRET with a dye located on the surface-covering protein.  相似文献   

2.
An amperometric biosensor based on acetylcholinesterase was constructed by simple adsorption of the enzyme on screen-printed electrodes (SPEs). This sensor was used to detect the inhibitory effects of organophosphorus and carbamate insecticides on acetylcholinesterase, and more particularly of chlorpyrifos ethyl oxon (CP-o). We demonstrate that enzyme adsorption on SPEs allows to obtain stable sensors that present good characteristics and are as efficient as other screen-printed biosensors based on covalent binding or entrapment of acetylcholinesterase (AChE).  相似文献   

3.
Existing biosensors employ two major components: analyte recognition and signal transduction. Although specificity is achieved through analyte recognition, sensitivity is usually enhanced through a chemical amplification stage that couples the two main units in a sensor. Although highly sensitive, the extra chemical amplification stage complicates the sensing protocol. In addition, it separates the two elements spatiotemporally, reducing the real‐time response of the biosensor. In this review, we discuss the new mechanochemical biosensors that employ mechanochemical coupling strategies to overcome these issues. By monitoring changes in the mechanical properties of a single‐molecule template upon analyte binding, single‐molecule sensitivity is reached. As chemical amplification becomes unnecessary in this single‐molecule mechanochemical sensing (SMMS) strategy, real‐time sensing is achieved.  相似文献   

4.
The material-tissue interaction that results from sensor implantation is one of the major obstacles in developing viable, long-term implantable biosensors. Strategies useful for the characterization and modification of sensor biocompatibility are widely scattered in the literature, and there are many peripheral studies from which useful information can be gleaned. The current paper reviews strategies suitable for addressing biofouling, one aspect of biosensor biocompatibility. Specifically, this paper addresses the effect of membrane biofouling on sensor sensitivity from the standpoint of glucose transport limitations. Part I discusses the in vivo and in vitro methods used to characterize biofouling and the effects of biofouling on sensor performance, while Part II presents techniques intended to improve biosensor biocompatibility.  相似文献   

5.
Biosensors that make use of transport processes across lipid membranes are very rare even though a stimulus, the binding of a single analyte molecule, can enhance the sensor response manifold if the analyte leads to the transport of more than one ion or molecule across the membrane. Prerequisite for a proper function of such membrane based biosensors is the formation of lipid bilayers attached to a support that allow for the insertion of membrane peptides and proteins in a functional manner. In this review, the current state of the art technologies to obtain lipid membranes on various supports are described. Solid supported membranes on transparent and electrically conducting surfaces, lipid bilayers on micromachined apertures and on porous materials are discussed. The focus lies on the applicability of such membranes for the investigation of transport phenomena across lipid bilayers facilitated by membrane embedded peptides, channel proteins and transporters. Carriers and channel forming peptides, which are easy to handle and rather robust, are used frequently to build up membrane based biosensors. However, channel forming proteins and transporters are more difficult to insert functionally and thus, there are yet only few examples that demonstrate the applicability of such systems as biosensor devices.   相似文献   

6.
The immobilisation of biological recognition elements onto a sensor chip surface is a crucial step for the construction of biosensors. While some of the optical biosensors utilise silicon dioxide as the sensor surface, most of the biosensor surfaces are coated with metals for transduction of the signal. Biological recognition elements such as proteins can be adsorbed spontaneously on metal or silicon dioxide substrates but this may denature the molecule and can result in either activity reduction or loss. Self assembled monolayers (SAMs) provide an effective method to protect the biological recognition elements from the sensor surface, thereby providing ligand immobilisation that enables the repeated binding and regeneration cycles to be performed without losing the immobilised ligand, as well as additionally helping to minimise non-specific adsorption. Therefore, in this study different surface chemistries were constructed on SPR sensor chips to investigate protein and DNA immobilisation on Au surfaces. A cysteamine surface and 1%, 10% and 100% mercaptoundecanoic acid (MUDA) coatings with or without dendrimer modification were utilised to construct the various sensor surfaces used in this investigation. A higher response was obtained for NeutrAvidin immobilisation on dendrimer modified surfaces compared to MUDA and cysteamine layers, however, protein or DNA capture responses on the immobilised NeutrAvidin did not show a similar higher response when dendrimer modified surfaces were used.  相似文献   

7.
Choi K  Kim JY  Ahn JH  Choi JM  Im M  Choi YK 《Lab on a chip》2012,12(8):1533-1539
A new platform for lab-on-a-chip system is suggested that utilizes a biosensor array embedded in a digital microfluidic device. With field effect transistor (FET)-based biosensors embedded in the middle of droplet-driving electrodes, the proposed digital microfluidic device can electrically detect avian influenza antibody (anti-AI) in real time by tracing the drain current of the FET-based biosensor without a labeling process. Digitized transport of a target droplet enclosing anti-AI from an inlet to the embedded sensor is enabled by the actuation of electrowetting-on-dielectrics (EWOD). A reduction of the drain current is observed when the target droplet is merged with a pre-existing droplet on the embedded sensor. This reduction of the drain current is attributed to the specific binding of the antigen and the antibody of the AI. The proposed hybrid device consisting of the FET-based sensor and an EWOD device, built on a coplanar substrate by monolithic integration, is fully compatible with current fabrication technology for control and read-out circuitry. Such a completely electrical manner of inducing the transport of bio-molecules, the detection of bio-molecules, the recording of signals, signal processing, and the data transmission process does not require a pump, a fluidic channel, or a bulky transducer. Thus, the proposed platform can contribute to the construction of an all-in-one chip.  相似文献   

8.
An artificial receptor and a signal transducer have been engineered on a lectin (saccharide-binding protein) surface by a post-photoaffinity labeling modification method. Saccharide binding can be directly and selectively read out by the fluorescence changes of the fluorophore via photoinduced electron transfer (PET) mode. Fluorescence titration with various saccharides reveals that molecular recognition by the artificial receptor is successfully coupled to the native binding site of the lectin, producing a novel fluorescent saccharide biosensor showing modulated specificity and enhanced affinity. Designed cooperativity between artificial and native molecular recognition modules was quantitatively demonstrated by the comparison of the binding affinities, and it represents a new strategy in molecular recognition. By using appropriate artificial receptors and various native lectins, this approach may provide many new semisynthetic biosensors for saccharide derivatives such as glycolipids and glycopeptides/proteins. An extended library of lectin-based biosensors is envisioned to be useful for glycome research, a newly emerging field of the post-genomic era.  相似文献   

9.
A general approach is described for the de novo design and construction of aptamer-based electrochemical biosensors, for potentially any analyte of interest (ranging from small ligands to biological macromolecules). As a demonstration of the approach, we report the rapid development of a made-to-order electronic sensor for a newly reported early biomarker for lung cancer (CTAP III/NAP2). The steps include the in vitro selection and characterization of DNA aptamer sequences, design and biochemical testing of wholly DNA sensor constructs, and translation to a functional electrode-bound sensor format. The working principle of this distinct class of electronic biosensors is the enhancement of DNA-mediated charge transport in response to analyte binding. We first verify such analyte-responsive charge transport switching in solution, using biochemical methods; successful sensor variants were then immobilized on gold electrodes. We show that using these sensor-modified electrodes, CTAP III/NAP2 can be detected with both high specificity and sensitivity (K(d) ~1 nM) through a direct electrochemical reading. To investigate the underlying basis of analyte binding-induced conductivity switching, we carried out F?rster Resonance Energy Transfer (FRET) experiments. The FRET data establish that analyte binding-induced conductivity switching in these sensors results from very subtle structural/conformational changes, rather than large scale, global folding events. The implications of this finding are discussed with respect to possible charge transport switching mechanisms in electrode-bound sensors. Overall, the approach we describe here represents a unique design principle for aptamer-based electrochemical sensors; its application should enable rapid, on-demand access to a class of portable biosensors that offer robust, inexpensive, and operationally simplified alternatives to conventional antibody-based immunoassays.  相似文献   

10.
Carbon nanoscroll (CNS) with extraordinary electrical, physical and optical properties is an ideal candidate on sensor applications. It has great potential in biosensing owing to its outstanding properties like large surface-to-volume ratio, high conductivity, high flexibility and biocompatibility. In this research, we demonstrate a CNS-based biosensor to electrochemically detect glucose with high specificity and sensitivity. To this end, glucose absorption effect on the sensing area in the form of carrier concentration and quantum capacitance variations is investigated. Also, the caused electrical response on CNS as a detection element is analytically proposed, in which significant current increase of the CNS-based biosensor is observed after exposure to glucose. The proposed CNS-based glucose biosensor exposes higher current compared to that of carbon nanotube counterpart for analogous ambient conditions. Moreover, the comparative results provide evidence of good consensus between the model and experimental data of platinum nanoparticles/graphene nanoscrolls (Pt/GSS) and Pt/nitrogen-doped GSS (Pt/N-GSS) nanocomposites-based biosensors. Main findings of this research can be served as a high throughput platform to analytically predict the behaviour of the sensing mechanism in glucose biosensors. The results further reveal that the CNS biosensor demonstrates not only high sensitivity and broad linear range but also long-term stability and low detection limit.  相似文献   

11.
A fractal analysis is presented for cellular analyte-receptor binding kinetics utilizing biosensors. Data taken from the literature can be modeled by using (a) a single-fractal analysis and (b) a single- and a dual-fractal analysis. Case (b) represents a change in the binding mechanism as the reaction progresses on the biosensor surface. Relationships are presented for the binding rate coefficient(s) as a function of the fractal dimension for the single-fractal analysis examples. In general, the binding rate coefficient is rather sensitive to the degree of heterogeneity that exists on the biosensor surface. For example, for the binding of mutagenized and back-mutagenized forms of peptide E1037 in solution to salivary agglutinin immobilized on a sensor chip, the order of dependence of the binding rate coefficient, k, on the fractal dimension, D(f), is 13.2. It is of interest to note that examples are presented where the binding coefficient (k) exhibits an increase as the fractal dimension (D(f)) or the degree of heterogeneity increases on the surface. The predictive relationships presented provide further physical insights into the binding reactions occurring on the surface. These should assist us in understanding the cellular binding reaction occurring on surfaces, even though the analysis presented is for the cases where the cellular "receptor" is actually immobilized on a biosensor or other surface. The analysis suggests possible modulations of cell surfaces in desired directions to help manipulate the binding rate coefficients (or affinities). In general, the technique presented is applicable for the most part to other reactions occurring on different types of biosensors or other surfaces. Copyright 2000 Academic Press.  相似文献   

12.
We demonstrate a new sensitive biosensor for detection of vital fungal spores of Aspergillus niger. The biosensor is based on silicon microfabricated cantilever arrays operated in dynamic mode. The change in resonance frequency of the sensor is a function of mass binding to the cantilever surface. For specific A. niger spore immobilization on the cantilever, each cantilever was individually coated with anti-Aspergillus niger polyclonal antibodies. We demonstrate the detection of single A. niger spores and their subsequent growth on the functionalized cantilever surface by online measurements of resonance frequency shifts. The new biosensor operating in humid air allows quantitative and qualitative detection of A. niger spores as well as detection of vital, functional spores in situ within approximately 4 h. The detection limit of the sensor is 103 CFU mL-1. Mass sensitivity of the cantilever sensor is approximately 53 pg Hz-1.  相似文献   

13.
Aptamer-based biosensors for the detection of HIV-1 Tat protein   总被引:7,自引:0,他引:7  
Two biosensors have been constructed using an RNA aptamer as biorecognition element. The aptamer, specific for HIV-1 Tat protein, has been immobilised on the gold surface of piezoelectric quartz crystals or surface plasmon resonance (SPR) chips to develop a quartz crystal microbalance (QCM)-based and an SPR-based biosensor, respectively. Both the biosensors were modified with the same immobilisation chemistry based on the binding of a biotinylated aptamer on a layer of streptavidin. The binding between the immobilised aptamer and its specific protein has been evaluated with the two biosensors in terms of sensitivity, reproducibility and selectivity. A protein very similar to Tat, Rev protein, has been used as negative control. The two biosensors both were very reproducible in the immobilisation and the binding steps. The selectivity was high in both cases.  相似文献   

14.
Advancement of hyperpolarized 129Xe MRI technology toward clinical settings demonstrates the considerable interest in this modality for diagnostic imaging. The number of contrast agents, termed biosensors, for 129Xe MRI that respond to specific biological targets, has grown and diversified. Directly functionalized xenon-carrying macrocycles, such as the large family of cryptophane-based biosensors, are good for localization-based imaging and provide contrast before and after binding events occur. Noncovalently functionalized constructs, such as cucurbituril- and cyclodextrin-based biosensors, benefit from commercial availability and optimal exchange dynamics for CEST imaging. In this work, we report the first directly functionalized cucurbituril used as a xenon biosensor. Biotinylated cucurbit[7]uril (btCB7) gives rise to a 129Xe hyperCEST response at the unusual shift of δ=28 ppm when bound to its protein target with substantial CEST contrast. We posit that the observed chemical shift is due to the deformation of btCB7 upon binding to avidin, caused by proximity to the protein surface. Conformational searches and molecular dynamics (MD) simulations support this hypothesis. This construct combines the strengths of both families of biosensors, enables a multitude of biological targets through avidin conjugation, and demonstrates the advantages of functionalized cucurbituril-based biosensors.  相似文献   

15.
We constructed the transferred ZnO biosensor and the grown ZnO biosensor by two different nano-ZnO immobilization approaches. And the influence of different assembly processes on the biosensor performance has been systematically investigated and compared. An enhanced sensitivity of the grown ZnO biosensor is found to be 52% higher than that of the transferred ZnO biosensor. Correspondingly, the other properties are also better in the grown ZnO biosensor, including the response time, the detection limit and the linear range. These results are well consistent with the fact that more glucose oxidase is immobilized on the well-aligned ZnO arrays, which have higher specific surface area and more direct electron communication path, in the grown sensor than the randomly distributed and stacked ZnO nanorods in the transferred sensor. The nano-ZnO grown directly has been demonstrated more desirable for enzymatic immobilization and signal transduction in the high performance biosensors.  相似文献   

16.
In prokaryotes, the ribosome binding sequence (RBS), located in the 5' untranslated region (5' UTR) of an mRNA, plays a critical role in enhancing mRNA translation and stability. To evaluate the effect of the RBS on the sensitivity and signal intensity of an environmental whole-cell biosensor, three Escherichia coli-based biosensors that respond to benzene, toluene, ethylbenzene, and the xylenes (BTEX) were constructed; the three biosensors have the same Pu promoter and xylR regulator from the Pseudomonas putida TOL plasmid but differ in the engineered RBS in their reporter genes. The results from time and dose-dependent induction of luminescence activity by 2-chlorotoluene showed that the BTEX-SE and BTEX-SD biosensors with engineered RBS had signal intensities approximately 10-35 times higher than the primary BTEX-W biosensor. The limits of detection (LOD) of the BTEX-SE and BTEX-SD biosensors were also significantly lower than the LOD of the BTEX-W biosensor (20 ± 5 μmol L(-1) and 25 ± 5 μmol L(-1) vs. 120 ± 10 μmol L(-1)). Moreover, the BTEX-SE and BTEX-SD biosensors responded three times more rapidly to the analytes. These results suggest that rationally designed RBS in the 5' UTR of a reporter gene may be a promising strategy for increasing the sensitivity, signal intensity, and response speed of whole-cell biosensors.  相似文献   

17.
The development of biosensors has been one of the key areas in biotechnology and biomedical studies. Often it is difficult to investigate the immobilized biomolecules on the surfaces for biosensor optimization. Atomic force microscopy (AFM) should provide an ideal means for the visualization of biosensor surface and for the investigation of biomolecule activities. Therefore, AFM has been employed to study the surface topography of immobilized glutamate dehydrogenase (GDH) on two-dimensional glutamate biosensor surfaces. Correlation between the surface topography and the activity of the biosensor was investigated. Surface analysis has revealed that the enzymatic activity of the immobilized GDH molecules on the biosensor surface is linked to surface roughness, as measured by the peak-to-valley distance. Fractal dimension of the immobilization sensor surface was found to be a good parameter for judging the quality of the immobilized biosensors. As enzyme immobilization time increases, the biosensor has its maximum activity with around 18 h of immobilization in 10–6 M GDH solution. Various biosensors prepared under different experimental conditions have been studied by AFM. This technique is shown to be an effective tool to characterize biosensor surfaces.  相似文献   

18.
Ultra-sensitive, label-free biosensors have the potential to have a tremendous impact on fields like medical diagnostics. For the majority of these Si-based integrated devices, it is necessary to functionalize the surface with a targeting ligand in order to perform specific biodetection. To do this, silane coupling agents are commonly used to immobilize the targeting ligand. However, this method typically results in the bioconjugation of the entire device surface, which is undesirable. To compensate for this effect, researchers have developed complex blocking strategies that result in selective patterning of the sensor surface. Recently, silane coupling agents were used to attach biomolecules to the surface of silica toroidal biosensors integrated on a silicon wafer. Interestingly, only the silica biosensor surface was conjugated. Here, we hypothesize why this selective patterning occurred. Specifically, the silicon etchant (xenon difluoride), which is used in the fabrication of the biosensor, appears to reduce the efficiency of the silane coupling attachment to the underlying silicon wafer. These results will enable future researchers to more easily control the bioconjugation of their sensor surfaces, thus improving biosensor device performance.  相似文献   

19.
Brownson DA  Banks CE 《The Analyst》2011,136(10):2084-2089
The electrochemical sensing of hydrogen peroxide is of substantial interest to the operation of oxidase-based amperometric biosensors. We explore the fabrication of a novel and highly sensitive electro-analytical biosensor using well characterised commercially available graphene and compare and contrast responses using Nafion -graphene and -graphite modified electrodes. Interestingly we observe that graphite exhibits a superior electrochemical response due to its enhanced percentage of edge plane sites when compared to graphene. However, when Nafion, routinely used in amperometric biosensors, is introduced onto graphene and graphite modified electrodes, re-orientation occurs in both cases which is beneficial in the former and detrimental in the latter; insights into this contrasting behaviour are consequently presented providing acuity into sensor design and development where graphene is utilised in biosensors.  相似文献   

20.
The development of biosensors has been one of the key areas in biotechnology and biomedical studies. Often it is difficult to investigate the immobilized biomolecules on the surfaces for biosensor optimization. Atomic force microscopy (AFM) should provide an ideal means for the visualization of biosensor surface and for the investigation of biomolecule activities. Therefore, AFM has been employed to study the surface topography of immobilized glutamate dehydrogenase (GDH) on two-dimensional glutamate biosensor surfaces. Correlation between the surface topography and the activity of the biosensor was investigated. Surface analysis has revealed that the enzymatic activity of the immobilized GDH molecules on the biosensor surface is linked to surface roughness, as measured by the peak-to-valley distance. Fractal dimension of the immobilization sensor surface was found to be a good parameter for judging the quality of the immobilized biosensors. As enzyme immobilization time increases, the biosensor has its maximum activity with around 18 h of immobilization in 10(-6) M GDH solution. Various biosensors prepared under different experimental conditions have been studied by AFM. This technique is shown to be an effective tool to characterize biosensor surfaces.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号