首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
作为一种简便高效的样品前处理技术,固相微萃取(SPME)在食品、环境水样和生物体液等复杂基质残留污染物检测中得到广泛应用。为进一步提高净化效率和降低使用成本等,大量文献报道了涂层纤维的制备条件和吸附剂的选择。本文综述了SPME涂层纤维的制备方法、材料及应用。描述了不同材料对于不同分析物的吸附原理,特别讨论了难挥发与热不稳定性分析物的SPME分析步骤,总结了SPME存在的问题及今后发展趋势,为后续SPME技术的开发提供理论依据。  相似文献   

2.
Sample preparation, such as extraction, concentration, and isolation of analytes, greatly influences their reliable and accurate analysis. In-tube solid-phase microextraction (SPME) is a new effective sample preparation technique using an open tubular fused-silica capillary column as an extraction device. Organic compounds in aqueous samples are directly extracted and concentrated into the stationary phase of capillary columns by repeated draw/eject cycles of sample solution, and they can be directly transferred to the liquid chromatographic column. In-tube SPME is an ideal sample preparation technique because it is fast to operate, easy to automate, solvent-free, and inexpensive. On-line in-tube SPME-performed continuous extraction, concentration, desorption, and injection using an autosampler, is usually used in combination with high performance liquid chromatography and liquid chromatography-mass spectrometry. This technique has successfully been applied to the determination of various compounds such as pesticides, drugs, environmental pollutants, and food contaminants. In this review, an overview of the development of in-tube SPME technique and its applications to environmental, clinical, forensic, and food analyses are described.  相似文献   

3.
Solid-phase microextraction (SPME) techniques are equally applicable to both volatile and non-volatile analytes, but the progress in applications to gas-phase separations has outpaced that of liquid-phase separations. The interfacing of SPME to gas chromatographic equipment has been straight-forward, requiring little modification of existing equipment. The requirement of solvent desorption for non-volatile or thermally labile analytes has, however, proven challenging for interfacing SPME with liquid-phase separations. Numerous options to achieve this have been described in the literature over the past decade, with applications in several different areas of analysis. To date, no single strategy or interface device design has proven optimal. During method development analysts must select the most appropriate interfacing technique among the options available. Out of these options three general strategies have emerged: (1) use of a manual injection interface tee; (2) in-tube SPME; and (3) off-line desorption followed by conventional liquid injection. In addition, there has been interest in coupling SPME directly to electrospray ionisation and matrix-assisted laser desorption ionisation (MALDI) for mass spectrometry. Several examples of each of these strategies are reviewed here, and an overview of their use and application is presented.  相似文献   

4.
The miniaturization and improvement of sample preparation is a challenge that has been fulfilled up to a point in many fields of analytical chemistry. Particularly, the hyphenation of microextraction with advanced analytical techniques has allowed the monitoring of target analytes in a vast variety of environmental samples. Several benefits can be obtained when miniaturized techniques such as solid-phase microextraction (SPME) or liquid-phase microextraction (LPME) are applied, specifically, their easiness, rapidity and capability to separate and pre-concentrate target analytes with a negligible consumption of organic solvents. In spite of the great acceptance that these green sample preparation techniques have in environmental research, their full implementation has not been achieved or even attempted in some relevant environmental matrices.  相似文献   

5.
Sample preparation is an essential step in analysis, greatly influencing the reliability and accuracy of resulted the time and cost of analysis. Solid-Phase Microextraction (SPME) is a very simple and efficient, solventless sample preparation method, invented by Pawliszyn in 1989. SPME has been widely used in different fields of analytical chemistry since its first applications to environmental and food analysis and is ideally suited for coupling with mass spectrometry (MS). All steps of the conventional liquid-liquid extraction (LLE) such as extraction, concentration, (derivatization) and transfer to the chromatograph are integrated into one step and one device, considerably simplifying the sample preparation procedure. It uses a fused-silica fibre that is coated on the outside with an appropriate stationary phase. The analytes in the sample are directly extracted to the fibre coating. The SPME technique can be routinely used in combination with gas chromatography, high-performance liquid chromatography and capillary electrophoresis and places no restriction on MS. SPME reduces the time necessary for sample preparation, decreases purchase and disposal costs of solvents and can improve detection limits. The SPME technique is ideally suited for MS applications, combining a simple and efficient sample preparation with versatile and sensitive detection. This review summarizes analytical characteristics and variants of the SPME technique and its applications in combination with MS.  相似文献   

6.
Recent developments in solid-phase microextraction   总被引:2,自引:0,他引:2  
The main objective of this review is to describe the recent developments in solid-phase microextraction technology in food, environmental and bioanalytical chemistry applications. We briefly introduce the historical perspective on the very early work associated with the development of theoretical principles of SPME, but particular emphasis is placed on the more recent developments in the area of automation, high-throughput analysis, SPME method optimization approaches and construction of new SPME devices and their applications. The area of SPME automation for both GC and LC applications is particularly addressed in this review, as the most recent developments in this field have allowed the use of this technology for high-throughput applications. The development of new autosamplers with SPME compatibility and new-generation metal fibre assemblies has enhanced sample throughput for SPME-GC applications, the latter being attributed to the possibility of using the same fibre for several hundred extraction/injection cycles. For LC applications, high-throughput analysis (>1,000 samples per day) can be achieved for the first time with a multi-SPME autosampler which uses multi-well plate technology and allows SPME sample preparation of up to 96 samples in parallel. The development and evolution of new SPME devices such as needle trap, thin-film microextraction and cold-fibre headspace SPME have offered significant improvements in performance characteristics compared with the conventional fibre-SPME arrangement. Figure Photo of a high-throughput multi-fibre SPME PAS autosampler  相似文献   

7.
Even after emergence of most advanced instrumental techniques for the final separation, detection, identification and determination of analytes, sample handling continues to play a basic role in environmental analysis of complex matrices. In fact, sample preparation steps are often the bottleneck for combined time and efficiency in many overall analytical procedures. Thus, it is not surprising that, in the last two decades, a lot of effort has been devoted to the development of faster, safer, and more environment friendly techniques for sample extraction and extract clean up, prior to actual instrumental analysis. This article focuses on the state of the art in sample preparation of environmental solid biological samples dedicated to persistent organic pollutants (POPs) analysis. Extraction techniques such as Soxhlet extraction, sonication-assisted extraction, supercritical fluid extraction (SFE), microwave-assisted extraction (MAE), pressurised liquid extraction (PLE) and matrix solid-phase dispersion (MSPD) are reviewed and their most recent applications to the determination of POPs in biota samples are provided. Additionally, classical as well as promising novel extraction/clean-up techniques such as solid phase microextraction (SPME) are also summarized. Finally, emerging trends in sample preparation able to integrate analytes extraction and their adequate clean-up are presented.  相似文献   

8.
Solid phase microextraction (SPME) is an increasingly common method of sample isolation and enhancement. SPME is a convenient and simple sample preparation technique for chromatographic analysis and a useful alternative to liquid-liquid extraction and solid phase extraction. SPME is speed and simply method, which has been widely used in environmental analysis because it is a rather safe method when dealing with highly toxic chemicals. A combination of SPME and gas chromatography (GC) permits both the qualitative and quantitative analysis of toxic industrial compounds, pesticides and chemical warfare agents (CWAs), including their degradation products, in air, water and soil samples. This work presents a combination of SPME and GC methods with various types of detectors in the analysis of CWAs and their degradation products in air, water, soil and other matrices. The combination of SPME and GC methods allows for low detection limits depending on the analyte, matrix and detection system. Commercially available fibers have been mainly used to extract CWAs in headspace analysis. However, attempts have been made to introduce new fiber coatings that are characterized by higher selectivities towards different analytes of interest. Environmental decomposition of CWAs leads to the formation of more hydrophilic products. These compounds may be isolated from samples using SPME and analyzed using GC however, they must often be derivatized first to produce good chromatography. In these cases, one must ensure that the SPME method also meets the same needs. Otherwise, it is helpful to use derivatization methods. SPME may also be used with fieldportable mass spectrometry (MS) and GC-MS instruments for chemical defense applications, including field sampling and analysis. SPME fibers can be taken into contaminated areas to directly sample air, headspaces above solutions, soils and water.  相似文献   

9.
赵金凤  王希越  娄大伟 《化学通报》2024,87(4):410-418,397
随着检测需求的提高与分析技术的发展,简单、自动化、环保与小型化的微型样品前处理技术越来越受到关注。针阱微萃取(NTME)是在固相微萃取(SPME)技术的理论基础上发展起来的一种新型微型萃取技术,其萃取装置将吸附剂填充到不锈钢针内制得,可避免固相微萃取纤维易碎及涂层脱落的问题,而且通过动态萃取,可使目标物被彻底萃取,具有更好的耐用性和富集能力。近年NTME结合气相色谱法在挥发性和半挥发性有机污染物分析中获得广泛应用,已有诸多关于NTME的研究被报道。吸附剂是影响NTME萃取性能的核心,本文简要概述了近年NTME的吸附剂种类,并综述了其在环境、食品、生物领域的应用进展。  相似文献   

10.
Solid-phase microextraction (SPME) has undergone a surge in popularity within the field of analytical chemistry in the past two decades since its introduction. Owing to its nature of extraction, SPME has become widely known as a quick and cost-effective sample preparation technique. Although SPME has demonstrated extraordinary versatility in sampling capabilities, the technique continues to experience a tremendous growth in innovation. Presently, increasing efforts have been directed towards the engineering of novel sorbent material in order to expand the applicability of SPME for a wider range of analytes and matrices. This review highlights the application of ionic liquids (ILs) and polymeric ionic liquids (PILs) as innovative sorbent materials for SPME. Characterized by their unique physico-chemical properties, these compounds can be structurally-designed to selectively extract target analytes based on unique molecular interactions. To examine the advantages of IL and PIL-based sorbent coatings in SPME, the field is reviewed by gathering available experimental data and exploring the sensitivity, linear calibration range, as well as detection limits for a variety of target analytes in the methods that have been developed.  相似文献   

11.
The analysis of samples contaminated by organic compounds is an important aspect of environmental monitoring. Because of the complex nature of these samples, isolating target organic compounds from their matrices is a major challenge. A new isolation technique, solid phase microextraction, or SPME, has recently been developed in our laboratory. This technique combines the extraction and concentration processes into one step; a fused silica fiber coated with a polymer is used to extract analytes and transfer them into a GC injector for thermal desorption and analysis. It is simple, rapid, inexpensive, completely solvent-free, and easily automated. To minimize matrix interferences in environmental samples, SPME can be used to extract analytes from the headspace above the sample. The combination of headspace sampling with SPME separates volatile and semi-volatile analytes from non-volatile compounds, thus greatly reducing the interferences from non-target compounds. This paper reports the use of headspace SPME to isolate volatile organic compounds from various matrices such as water, sand, clay, and sludge. By use of the technique, benzene, toluene, ethyl-benzene, and xylene isomers (commonly known as BTEX), and volatile chlorinated compounds can be efficiently isolated from various matrices with good precision and low limits of detection. This study has found that the sensitivity of the method can be greatly improved by the addition of salt to water samples, water to soil samples, or by heating. Headspace SPME can also be used to sample semi-volatile compounds, such as PAHs, from complex matrices.  相似文献   

12.
Microextraction is considered as one of the most critical steps in the entire analytical process because it can effectively remove interference and pre-concentrate the target analytes. Molecularly imprinted polymers (MIPs) are synthetic polymers with a predetermined selectivity for a given analyte, or group of structurally related compounds, which are excellent materials for sample preparation in the process of microextraction owing to their high selectivity and ability. This review provides a critical overview of the synthesis and characterization of MIPs, with a focus on recent applications in the field of solid-phase microextraction (SPME) and liquid-phase microextraction (LPME). The advantages and drawbacks of the applications of MIPs used in SPME and LPME as well as the future expected trends are also discussed.  相似文献   

13.
近年来,与实时直接分析质谱(DART-MS)相结合的样品预处理技术发展迅速,使得对复杂生物、环境、法医学、食品、个体小生物以及单细胞样品中的分析物进行直接分析成为可能。然而固体基质内部分析物检测困难、痕量分析物检测性能不佳已成为限制DART-MS进一步发展的关键问题。针对这些问题,多年来,研究人员在不同领域对样品预处理与质谱联用进行了多种尝试。该文以固相萃取(SPE)、分散固相萃取(DSPE)、搅拌棒吸附萃取(SBSE)、固相微萃取(SPME)、机械化学提取(MCE)和微波提取(MAE)等样品预处理技术为例,对不同研究领域中样品预处理技术与DART-MS联用的研究成果进行了综述,并对未来的发展趋势进行了展望。希望该综述能为开发与DART-MS联用的新型样品处理技术提供参考和帮助。  相似文献   

14.
Solid-phase microextraction (SPME) is a miniaturized and solvent-free sample preparation technique for chromatographic–spectrometric analysis by which the analytes are extracted from a gaseous or liquid sample by absorption in, or adsorption on, a thin polymer coating fixed to the solid surface of a fiber, inside an injection needle or inside a capillary. In this paper, the present state of practical performance and of applications of SPME to the analysis of blood, urine, oral fluid and hair in clinical and forensic toxicology is reviewed. The commercial coatings for fibers or needles have not essentially changed for many years, but there are interesting laboratory developments, such as conductive polypyrrole coatings for electrochemically controlled SPME of anions or cations and coatings with restricted-access properties for direct extraction from whole blood or immunoaffinity SPME. In-tube SPME uses segments of commercial gas chromatography (GC) capillaries for highly efficient extraction by repeated aspiration–ejection cycles of the liquid sample. It can be easily automated in combination with liquid chromatography but, as it is very sensitive to capillary plugging, it requires completely homogeneous liquid samples. In contrast, fiber-based SPME has not yet been performed automatically in combination with high-performance liquid chromatography. The headspace extractions on fibers or needles (solid-phase dynamic extraction) combined with GC methods are the most advantageous versions of SPME because of very pure extracts and the availability of automatic samplers. Surprisingly, substances with quite high boiling points, such as tricyclic antidepressants or phenothiazines, can be measured by headspace SPME from aqueous samples. The applicability and sensitivity of SPME was essentially extended by in-sample or on-fiber derivatization. The different modes of SPME were applied to analysis of solvents and inhalation narcotics, amphetamines, cocaine and metabolites, cannabinoids, methadone and other opioids, fatty acid ethyl esters as alcohol markers, γ-hydroxybutyric acid, benzodiazepines, various other therapeutic drugs, pesticides, chemical warfare agents, cyanide, sulfide and metal ions. In general, SPME is routinely used in optimized methods for specific analytes. However, it was shown that it also has some capacity for a general screening by direct immersion into urine samples and for pesticides and other semivolatile substance in the headspace mode.  相似文献   

15.
Solid-phase microextraction (SPME) is a technique for extraction of organic compounds from gaseous, aqueous, and solid matrices. SPME is rapid and simple, ideal for automation and for in situ measurements, and no harmful solvents are needed. The principle of SPME involves equilibration of the analytes between the sample matrix and an organic polymeric phase coated on a fused-silica fiber. SPME is traditionally combined with analysis by gas chromatography (GC) and this combination has proved sensitive, accurate, and precise for quantitative analysis of different classes of volatile compound. More recently SPME has been coupled with liquid chromatography to widen its range of application to non-volatile and thermally unstable compounds also. This article reviews the status of SPME coupled with liquid chromatography. It focuses on different applications of the technique, e.g. environmental samples, biological fluids, and food samples, to show that SPME-HPLC has great potential in the analysis of a wide range of compounds in different matrices.  相似文献   

16.
Malik AK  Kaur V  Verma N 《Talanta》2006,68(3):842-849
This paper reviews the practical applications of solid phase microextraction-High performance liquid chromatography in the analysis of toxic metal species as these are important contaminants and are carcinogenic. Their determination in formulations, in feed and food, and in complex environmental matrices (e.g., waste water and industrial effluents) often requires analytical methods capable of high efficiency, unique selectivity, and high sensitivity. Solid phase microextraction (SPME) requires low solvent consumption and is quick in use. SPME is used for extraction and online desorption of analytes with the mobile phase of HPLC and subsequent detection by UV, ICP-MS or ESI-MS as detectors. Different SPME-HPLC methods are summarized in this article to demonstrate the usefulness of this technique for metallic species of As, Cr, Pb, Hg and Se.  相似文献   

17.
固相微萃取(Solid-phase microextraction,SPME)技术因其具有操作简单、萃取时间短、无需有机溶剂、易于自动化操作等优点,成为近年来发展起来的一种新型样品前处理技术。涂层是SPME技术的核心,决定了涂层萃取的选择性和容量。离子液体和聚离子液体因具有环境友好、蒸汽压低、热稳定性好、设计灵活、粘度大等特点,已作为一类新的涂层材料广泛应用于SPME,并对各种分析物均展现出良好的萃取效果和选择性。本文从制备技术、形貌、选择性、稳定性、寿命、应用等方面综述了近年来离子液体和聚离子液体基SPME涂层的研究进展,对它们的优缺点进行了对比讨论,并对其未来发展方向进行了展望。  相似文献   

18.
Gold nanomaterials (Au NMs) have attracted increasing attention in biomedicine due to their facile preparation, multifunctional modifications, unique optical and electrical properties, and good biocompatibility. The physicochemical properties of Au NMs at nanoscale, like size, shape, surface chemistry, and near field effects, are rendering Au NMs potent candidates in biomedicine. Thus, risk assessment of negative effects of Au NMs on biological systems is becoming urgent and necessary for future applications. In this review, we summarize up-to-date progresses on the preparation and modification of Au NMs and their biomedical applications, including biosensor, bioimaging and phototherapy, gene/drug delivery. Finally, we discuss the potential risk of Au NMs to biological systems, which is instructive for rationally designing and preparing nanomaterials for safe applications in nanomedicine.  相似文献   

19.
Solid Phase Microextraction (SPME)   总被引:1,自引:0,他引:1  
Solid phase microextraction (SPME) was developed to address the need for a fast, solvent-free and field compatible sample preparation method. It has been applied to a range of applications including environmental, industrial hygiene, process monitoring, clinical, forensic, food and drug analysis. In SPME, coated fibers are used to isolate and concentrate analytes into a range of coating materials. After extraction, the fibers are transferred, with the help of the syringe-like handling device, to analytical instruments for separation and quantification of the target analytes.In the past 20 years the number of instrumental techniques available to the chemist has grown exponentially. In order to help our readers keep up with this rapidly growing field, tutorial articles on chemical instrumentation will be a regular feature of The Chemical Educator. The articles are designed to serve as a brief introduction to emerging instrumetal techniques with an outline of the underlying principles and major applications. —Martin Schimpf, Series Editor  相似文献   

20.
Studies have been performed assessing the feasibility and characterizing the automation of solid-phase microextraction (SPME) on a multi-well plate format. Four polycyclic aromatic hydrocarbons (PAHs), naphthalene, fluorene, anthracene and fluoranthene, were chosen as test analytes to demonstrate the technique due to their favorable partition coefficients, K(fw), between polydimethylsiloxane (PDMS) extraction phases and water. Four different PDMS configurations were investigated regarding their suitability. These included (i) a PDMS membrane; (ii) a multi-fiber device containing lengths of PDMS-coated flexible wire; (iii) a stainless steel pin covered with silicone hollow fiber membrane and (iv) commercial PDMS-coated flexible metal fiber assemblies. Of these configurations, the stainless steel pin covered with silicone tubing was chosen as a robust alternative. An array of 96 SPME devices that can be placed simultaneously into a 96-well plate was constructed to demonstrate the high-throughput potential when performing multiple microextractions in parallel. Different agitation methods were assessed including magnetic stirring, sonication, and orbital shaking at different speeds. Orbital shaking whilst holding the SPME device in a stationary position provided the optimum agitation conditions for liquid SPME. Once the analytes had been extracted, desorption of the analytes into an appropriate solvent was investigated. Liquid-phase SPME and solvent desorption on the multi-well plate format is shown to be a viable alternative for automated high-throughput SPME analysis compatible with both gas- and liquid-chromatography platforms.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号