首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 406 毫秒
1.
The Chromatographic retention and separation of NO 2 - , Br-, NO 3 - , and I- anions on a column packed with Nucleosil 100-5 C18 dynamically modified with trimethyloctadecylammonium bromide (TMODAB) was studied using direct UV detection. A procedure was developed for the determination of the above anions in the concentration range 0.06-2500 Μg/L without preconcentration. Sample preparation involved only the elimination of organic impurities (if present) from the test sample. The procedure was used for the determination of NO 2 - and NO 3 - anions in Baikal Lake water and in an aerosol extract.  相似文献   

2.
A dicationic imidazolium ionic liquid modified silica stationary phase was prepared and evaluated by reversed‐phase/anion‐exchange mixed‐mode chromatography. Model compounds (polycyclic aromatic hydrocarbons and anilines) were separated well on the column by reversed‐phase chromatography; inorganic anions (bromate, bromide, nitrate, iodide, and thiocyanate), and organic anions (p‐aminobenzoic acid, p‐anilinesulfonic acid, sodium benzoate, pathalic acid, and salicylic acid) were also separated individually by anion‐exchange chromatography. Based on the multiple sites of the stationary phase, the column could separate 14 solutes containing the above series of analytes in one run. The dicationic imidazolium ionic liquid modified silica can interact with hydrophobic analytes by the hydrophobic C6 chain; it can enhance selectivity to aromatic compounds by imidazolium groups; and it also provided anion‐exchange and electrostatic interactions with ionic solutes. Compared with a monocationic ionic liquid functionalized stationary phase, the new stationary phase represented enhanced selectivity owing to more interaction sites.  相似文献   

3.
A two-dimensional ion chromatography (2D-IC) approach has been developed which provides greater resolution of complex samples than is possible currently using a single column. Two columns containing different stationary phases are connected via a tee-piece, which enables an additional eluent flow and independent control of eluent concentration on each column. The resultant mixed eluent flow at the tee-piece can be varied to produce a different eluent concentration on the second column. This allows analytes strongly retained on the first column to be separated rapidly on the second column, whilst maintaining a highly efficient, well resolved separation of analytes retained weakly on the first column. A group of 18 inorganic anions has been separated to demonstrate the utility of this approach and the proposed 2D-IC method provided separation of this mixture with resolution of all analytes greater than 1.3. Careful optimisation of the eluent profiles on both columns resulted in run times of less than 28 min, including re-equilibration. Separations were performed using isocratic or gradient elution on the first column, with an isocratic separation being used on the second column. Switching of the analytes onto the second column was performed using a gradient pulse of concentrated eluent to quickly elute strongly retained analytes from the first column onto the second column. The separations were highly repeatable (RSD of 0.01–0.12% for retention times and 0.08–2.9% for peak areas) and efficient (typically 8000–260,000 plates). Detection limits were 3–80 ppb.  相似文献   

4.
The application of ion chromatography with the single pump cycling‐column‐switching technique was described for the analysis of trace inorganic anions in weak acid salts within a single run. Due to the hydrogen ions provided by an anion suppressor electrolyzing water, weak acid anions could be transformed into weak acids, existing as molecules, after passing through the suppressor. Therefore, an anion suppressor and ion‐exclusion column were adopted to achieve on‐line matrix elimination of weak acid anions with high concentration for the analysis of trace inorganic anions in weak acid salts. A series of standard solutions consisting of target anions of various concentrations from 0.005 to 10 mg/L were analyzed, with correlation coefficients r ≥ 0.9990. The limits of detection were in the range of 0.67 to 1.51 μg/L, based on the signal‐to‐noise ratio of 3 and a 25 μL injection volume. Relative standard deviations for retention time, peak area, and peak height were all less than 2.01%. A spiking study was performed with satisfactory recoveries between 90.3 and 104.4% for all anions. The chromatographic system was successfully applied to the analysis of trace inorganic anions in five weak acid salts.  相似文献   

5.
Conventional silica columns dynamically modified with cetyltrimethylammonium ions were evaluated for the determination of UV-absorbing bromide, nitrate, and nitrite in seawater samples. Cetyltrimethylammonium, which is a quaternary ammonium ion, was dynamically introduced onto silica surfaces. The first layer of the modifier was introduced by electrostatic interaction, whereas the second layer was introduced by hydrophobic interaction. The latter layer worked as the anion-exchange sites. The modified conventional silica columns could be used for separation of inorganic anions. Separation of authentic mixture of five anions was achieved within 17 min. The addition of 0.1 mM cetyltrimethylammonium ion to the eluent improved the repeatability of the retention time. Seawater samples could be directly injected onto the prepared conventional silica columns, and bromide, nitrate, and nitrite levels were determined to be 69, 0.13, and 0.016 ppm, respectively.  相似文献   

6.
From the viewpoint of a graphite carbon column with excellent durability, it was applied to the ion chromatography (IC) of several organic acids. The carbon column was permanently coated with the cetyltrimethylammonium (CTMA) ion, and the elution behaviors of several organic acids (acetic acid, lactic acid, succinic acid, malic acid, tartaric acid, citric acid) and inorganic anions (Cl, NO2, NO3, SO42−) were examined according to a non-suppressed IC coupled with conductivity detector, when an ion-exchange ability was given to the graphite carbon column. When salicylic acid and sodium salicylate were used as a mobile phase, each organic acid are analyzed approximately 10 min. But the separation of malic acid, chloride and nitrite was difficult. When benzoic acid and 2-amino-2-hydroxymethyl-1,3-puropanediol (tris aminomethane) were used as a mobile phase, tartaric acid and citric acid, etc. with large valency showed tendency to which the width of each peaks extended and retention time increased. However, it was possible to separate excellently for the analytes detected within 10 min. The developed method was then applied to the determination of organic acids in several food samples.  相似文献   

7.
An ion chromatography method is described for the simultaneous determination of anions (Cl, NO3, and SO42–) and cations (Na+, NH4+, K+, Mg2+, and Ca2+) using a single pump, a single eluent and a single detector. An anion-exchange column modified with chondroitin sulfate C facilitated the elution of the above three anions using 5 mM tartaric acid as the eluent in isocratic mode, whereas the same eluent facilitated the separation of the above five cations on a commercially-available cation-exchange column. The separation columns were connected in series via two six-port switching valves, so the required cation-exchange or anion-exchange separation could be carried out by selecting the appropriate positions for the switching valves. The separations were completed in 30 min.  相似文献   

8.
Summary In order to study the occurrence of the opiate pentapeptide -[D-Ala2,4, Tyr5] CM-5-NH2 in the 10–9–10–5 M concentration range, we have developed a new method consisting of extraction of the peptide from its buffered aqueous medium onto a reversed phase cartridge of 50 L void volume, followed by on-line injection onto a Cu(II) modified silica gel column. The acetonitrile-rich mobile phase allows detection of the natural fluorescence of the peptide at the picomole level.  相似文献   

9.
Suzuki A  Lim LW  Hiroi T  Takeuchi T 《Talanta》2006,70(1):190-193
Monolithic silica capillary columns dynamically modified with quaternary ammonium ions were evaluated for the determination of bromide in seawater samples. A quaternary ammonium ion such as cetyltrimethylammonium ion was dynamically introduced onto monolithic silica surfaces. The first layer of the modifier was introduced by electrostatic interaction, whereas the second layer was introduced by hydrophobic interaction. The latter layer worked as the anion-exchange sites. The modified monolithic silica capillary columns could be used for rapid separation of inorganic anions. Separation of authentic mixture of five anions was achieved within a few minutes. The addition of small amount of the modifier in the eluent improved the repeatability of the retention time. Seawater samples could be directly injected onto the prepared capillary columns, and bromide could be determined to be 63 mg/L.  相似文献   

10.
Feng  Y. Q.  Shibukawa  M.  Oguma  K. 《Chromatographia》1995,41(5-6):532-538
Summary The reversed-phase ion-pair liquid chromatographic behaviour of several metal complexes with 5-sulphoquinoline-8-ol (HQS) on an octadecyl-modified silica column was investigated by using a fluorescence detector. The aluminum complex gave two peaks on the chromatograms when eluents containing phosphate buffer were used. The effects of the pH of the eluent, HQS concentration, the nature of anions in the eluent, and the column temperature on the retention behaviour of the aluminum complex are discussed on the basis of the equilibria and the kinetics of the complexation of the aluminum ion with HQS and anions in the eluent. The equilibrium constant for the interconversion reaction between the two Al(III)-HQS species which correspond to the two peaks observed and the second stepwise formation constant for the Zn(II)-HQS complex were evaluated from the HPLC data obtained.  相似文献   

11.
Kozaki D  Shi CH  Tanaka K  Nakatani N 《色谱》2012,30(4):361-364
To enhance the conductivity detection sensitivity of common anions(Na-anions) in electrostatic ion chromatography(EIC) by elution with water,a conductivity enhancement column packed with strong acid cation exchange resin in the H-form was inserted between an octadecyl silane(ODS)-silica separation column modified with zwitterionic surfactant(CHAPS: 3-{(3-cholamidopropyl)-dimethylammonio}propanesulfonate) and a conductivity detector.Specifically,the Na-anion pairing is converted to H-anion pairing after the EIC separation and then detected sensitively by the conductivity detector.The effects of conductivity enhancement and suppression in the EIC by the enhanced conductivity detection were characterized for the common strong acid anions such as SO2-4,Cl-,NO-3,I-and ClO-4 and weak acid anions such as F-,NO-2,HCOO-,CH3COO-and HCO-3.For the conductivity enhancement effect in the EIC,it is found that the conductivity of measured for all strong acid anions(Na-anions) was enhanced according to the theoretical conductivity predicted for H-anions and that of the measured for weak acid anions was suppressed depending on their pKa of H-anions.For the calibration linearity in the EIC,the strong acid anions were linear(r2=0.99-1.00) because the degree of dissociation is almost 1.0 over all the concentration range and that of the weak acid anions was non-linear because the degree of dissociation decreased by increasing the concentration of the weak acid anions.In conclusion,the EIC by enhanced conductivity detection was recognized to be useful only for the strong acid anions in terms of conductivity detection and calibration linearity.  相似文献   

12.
An analytical method was developed for the simultaneous determination of thiocyanate and iodide by reversed‐phase liquid chromatography with UV detection using imidazolium ionic liquids as mobile phase additives. The chromatographic behaviors of the two anions on a C18 column were studied and compared with four types of reagents including imidazolium ionic liquids, pyridinium ionic liquids, 4‐aminophenol hydrochloride and tetrabutylammonium as mobile phase additives. The effects of the concentrations of imidazolium ionic liquids, organic solvents and detection wavelength on separation and detection of the anions were investigated. The role of ionic liquids, retention rules and mechanisms were discussed. The separation of the anions was performed on the C18 reserved‐phase column using acetonitrile‐0.3 mmol/L 1‐amyl‐3‐methylimidazolium tetrafluoroborate (10:90, v/v) as mobile phase, with column temperature of 35°C, flow rate of 1 mL/min and detection wavelength of 210 nm. Under these conditions, the two anions can be completely separated within 6 min. The limits of detection were 0.05 mg/L. The method was applied for the determination of thiocyanate and iodide in ionic liquid samples and iodide drugs, and the spiked recoveries ranged from 97 to 101%. The method is simple, accurate and meets the requirements of quantitative analysis for thiocyanate and iodide.  相似文献   

13.
Summary An HPLC method with fluorescence detection is presented for the analysis of difloxacin (DIF) and sarafloxacin (SAR) in rabbit plasma using norfloxacin (NOR) as internal standard (Figure 1). Plasma sample preparations were carried out by adding phosphate buffer (pH 7.4, 0.1 M), followed by extraction with trichloromethane. Fluoroquinolones were separated on a reversed-phase column using an aqueous phosphate solution-acetonitrile (82:18) mobile phase. The concentrations of NOR, SAR and DIF eluting off the column, with retention times of 2.16, 5.60 and 6.20, respectively, were monitored by fluorescence detection atλ ex 338 andλ em 425 nm. The quantitation limit was 12 ng mL−1 for SAR and DIF. Standard curves were linearly related to concentration in the range from 1 to 1500 ng mL−1. Recovery was determined as 76% and 70% for SAR and DIF, respectively. Inter-and intraassay coefficients of variation were less than 6% for all compounds.  相似文献   

14.
Summary The chromatographic behaviour of anions on paper strips treated with tri-n-octylamine (TOA) salts or Aliquat 336 and developed with aqueous solutions of acetic, formic, monochloroacetic or trifluoroacetic acids and their sodium salts was investigated. Liquid-liquid extraction of organic acids by 0.1 M solution of TOA in benzene as well as the anion exchange between benzene solutions of TOA salts or Aliquat 336 (in acetate form) in benzene and aqueous solutions of sodium halides was also studied. It was found that extraction increases in the following order of the acids: CH3COOOH<HCOOH<CH2CICOOH<CF3COOH; the relative affinity of organic anions to the quaternary alkyl-ammonium cation also increase in a similar order. The extraction of acid in excess over the amount necessary to neutralize the amine was observed for all four acids. The RF values of anions investigated depend markedly on the type of organic acids or their salts and their concentration in the mobile phase. Halide ions are more strongly retained on paper treated with Aliquat 336 as compared with TOA salts. The chromatographic systems investigated offer many possibilities to separate various anion mixtures.Parts and II: refs. [1, 2].  相似文献   

15.
Summary Dobutamine is one of the synthetic catecholamines acting directly onβ 1-receptors. For the analysis of dobutamine in rat plasma samples, a selective and sensitive liquid chromatographic method is described. After a simple liquid-liquid extraction, separation of the analyte was performed using a reversed-phase ion-pair system with an octyl modified silica column. The solute was detected by fluorescence detection, applying an excitation wavelength of 285nm and an emission wavelength of 313nm. The (im)possibilities of the application of the normally used assays for the isolation, concentration and quantitation of catecholamines are discussed. By the addition of a minimum amount of modifier to the mobile phase, the selectivity of the system was increased significantly. With this method the detection limit is 9ng/ml in 0.2ml plasma samples. The application of the method is shown in rat plasma samples by measuring the concentration-time curves to establish plasma level-effect relationships for this drug.  相似文献   

16.
A multiresidue method for the analysis, in egg matrices, of residues of nine quinolones used in veterinary medicine, has been developed and validated according to the provisions of Council Decision 2002/657. Compounds were extracted by a pressurized liquid extraction (PLE) technique using a 1:1 mixture of acetonitrile and a phosphoric acid buffer (pH 3.0) at 70 °C. The obtained extract was clear enough, so that no further clean-up was necessary. Analytes were determined by liquid chromatography (LC) with fluorescence detection (FL). Two chromatographic columns were compared: a high-purity silica Inertsil C8 column and a newly developed Kinetex C18 core-shell technology column. Validation was carried out at four concentration levels, using both chromatographic columns. Precision in terms of reproducibility standard deviation was between 7% and 23%, and good recoveries were obtained. Decision limit (CCα) and detection capability (CCβ) values obtained with the Inertsil and Kinetex columns were in the 0.2-19.8 μg kg−1 and 0.4-33.5 μg kg−1 concentration ranges, respectively. The proposed method allows residues of quinolones banned for use with laying hens to be detected and quantified in eggs. About twenty-four samples per day can be processed.  相似文献   

17.
Hong Yu  Hongjing Ai  Qian Chen 《Chromatographia》2009,70(7-8):1017-1022
Ion-interaction chromatography with direct conductivity detection has been used for analysis of nitrate and nitrite. Chromatographic separation was performed on a monolithic silica-based C18 column dynamically modified with tetrabutylammonium (TBA+). Using the optimized mobile phase, containing 2.0 mmol L?1 TBA+ and 0.8 mmol L?1 citrate (pH 6.0), delivered at a flow rate of 6.0 mL min?1, separation of five anions (chloride, nitrite, bromide, nitrate, and sulfate) was achieved in only 40 s at a column temperature of 30 °C. The detection limits for nitrate and nitrite were 0.74 and 0.92 mg L?1, respectively. The relative standard deviation (RSD, n = 5) of the retention times of nitrate and nitrite was 0.1% and RSD of chromatographic peak areas were 0.4 and 0.2%, respectively. The method was successfully used for analysis of the anions in groundwater. Recovery of nitrate and nitrite was 99.1 and 105%, respectively.  相似文献   

18.
A novel form of reversed-phase liquid chromatography (RPLC) by the dynamically modified hydrophilic interaction monolithic column has been described in this paper. A porous poly(SPMA-co-PETA) monolith with strong cation-exchange (SCX) was prepared and the resulting monolith showed a typical hydrophilic interaction chromatography (HILIC) mechanism at higher organic solvent content (ACN% > 50%). The good selectivity for neutral, basic and acidic polar analytes was observed in the HILIC mode. In order to increase the hydrophobic interaction, the monolith with SCX was dynamically modified with a long-chain quaternary ammonium salt, cetyltrimethylammonium bromide (CTAB), which was added to the mobile phase. CTAB ions were adsorbed onto the surface of the SCX monolithic material, and the resulting hydrophobic layer was used as the stationary phase. Using the dynamically modified SCX monolithic column, neutral, basic and acidic hydrophobic analytes were well separated with the RPLC mode.  相似文献   

19.
Muhammad Amin 《Talanta》2007,71(4):1470-1475
A convenient ion chromatography method has been proposed for the routine and simple determination of anions (Cl, SO42− and NO3) and/or cations (Na+, NH4+, K+, Mg2+ and Ca2+) using a single pump, a single eluent and a single detector. The present system used cation-exchange and anion-exchange columns connected in series via two 6-port switching valves or a single 10-port valve. The connection order of the ion-exchange columns could be varied by switching the valve(s). The present system therefore allowed the separation of either cations or anions in a single chromatographic run. While one ion-exchange column is being operated, the other ion-exchange column is being conditioned, i.e., the columns are always ready for analysis at any time. When 2.4 mM 5-sulfosalicylic acid was used as the eluent, the three anions and the five cations could be separated on the anion-exchange column and cation-exchange column, respectively. In order to obtain the separations of the target ions, the injection valve was placed between the two columns. Complete separations of the above anions or cations were demonstrated within 10 min each. The detection limits at S/N = 3 were 19-50 ppb (μg/l) for cations and 10-14 ppb for anions. The relative standard deviations of the analyte ions were less than 1.1, 2.9 and 2.8% for retention time, peak area and peak height, respectively. This proposed technique was applied to the determination of common anions and cations in river water samples.  相似文献   

20.
Summary The optode with fair selectivity for salicylate and aspirin is based on the use of a new lipophilic carrier for aromatic carboxylic acids, namely (±) n-butyl O-(1-naphthylaminocarbonyl) lactate (BNAL). The sensing scheme involves co-extraction of both salicylate anion and a proton from the aqueous sample medium into a pvc layer using BNAL as a salicylate carrier, and a pH-sensitive dye as a lipoid proton carrier, both contained in the pvc membrane. BNAL transports the salicylate anion into the pvc lipid membrane. In order to maintain electro-neutrality, the proton carrier dye simultaneously extracts a proton into the pvc membrane, thereby becoming protonated. As a result, the dye undergoes a colour change which is detected via measurement of fluorescence intensity. The sensor is fully reversible and has a dynamic range from 0.1 to 30 mmol/l salicylate at pH 5.00, but the response function is highly pH-dependent. The effect of 25 interfering anions was investigated, and optical selectivity coefficients were determined. It is also shown that by proper variation of the membrane composition, selectivities for other carboxy anions can be obtained. The method has been applied to determine aspirin in tablets using flow injection analysis, and the results were found to be satisfactory.On leave of absence from the Department of Chemistry, Nankai University, CN-300071 Tianjin, P. R. China  相似文献   