首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Two capillary isoelectric focusing (CIEF) systems have first been optimized: one uses a bare silica capillary and 30% (v/v) of glycerol in the separation medium while the other uses a coated capillary and an aqueous background electrolyte. To perform permanent capillary coating, two neutral polymers have been compared: hydroxypropylcellulose (HPC) and polyvinylalcohol (PVA). HPC coating gave best results for electroosmotic flow (EOF) limitation on a wide pH range: as compared to a bare silica capillary, it allowed to decrease EOF by 96% at pH 7.2 after acidic and basic treatments, whereas PVA coating lead only to a 76% decrease. The glycerol CIEF system was more satisfying for the separation of model proteins classically used as pI markers. Finally, the use of "narrow pH cuts" of carrier ampholytes added to commercial ampholyte mixtures allowed increasing resolution up to a factor 2.4 at a chosen pH for the separation of pI markers and milk proteins.  相似文献   

2.
The use of quasi-isoelectric anolytes and catholytes has been investigated to improve CIEF performances. Narrow pH cuts of carrier ampholytes (NC) have been compared to more conventional couples of anolytes/catholytes (phosphoric acid/sodium hydroxide and glutamic acid/lysine). First, a CIEF setup that consists in a bare silica capillary and 70:30 water/glycerol separation medium has been used. The experiments have shown that when using NC instead of more classical anolytes and catholytes, an increase in the protein detection time was observed and the resolutions obtained for neutral and acidic proteins were doubled. Moreover, according to the NC fraction used, the resolution was modified. In order to investigate further the mechanisms involved, a second setup using a capillary coated with hydroxypropylcellulose was used. With this setup no difference has been observed when changing anolyte and catholyte nature. A simple methodology has then been developed to evaluate EOF during focusing and mobilization steps of CIEF experiments. It highlighted the crucial role played by EOF when using a bare silica capillary. EOF indeed decreased by 33% during mobilization step when using NC instead of classical anolytes and catholytes.  相似文献   

3.
In this study, narrow pH cuts of carrier ampholytes have been used as buffers in CE for the analysis of protein tryptic digests. Their low conductivity allows very efficient separations under high electric field strength without inducing any significant Joule heating. In this study, the capabilities of narrow pH cuts of carrier ampholytes for the separation of protein tryptic digests have been assessed. Three proteins of different molecular masses have been studied: cytochrome C (horse heart), beta-lactoglobulin B (bovine) and human transferrin. Efficient, rapid and repeatable separations of the peptides resulting from the tryptic digestion have been achieved in this buffer. Moreover, the feasibility of the coupling of carrier ampholyte-based capillary electrophoresis with ESI-MS has been demonstrated through the study of the cytochrome C tryptic digest.  相似文献   

4.
Beckers JL 《Electrophoresis》2003,24(3):548-556
A lot of phenomena, occuring in capillary zone electrophoresis (CZE), are linked with the ionic concentration of the background electrolyte (BGE). If weak bases and acids are used as BGEs in CZE, at a pH where they are scarcely ionized, the ionic concentration of the BGE is very low and this brings a strong peak broadening, limited sample stacking and low sample load. Because the electromigration dispersion increases extremely, moreover, the existence of low-conductivity BGEs in CZE is a contradiction in terms. The behavior of ampholytes as BGE in CZE is examined, by means of histidine as a model ampholyte. For BGEs consisting of histidine, important parameters, including the ionic concentrations, buffer capacity, transfer ratio, and the indicator for electromigration dispersion E(1)m(1)/E(2)m(2), are calculated at various pH. Although the transfer ratio is fairly constant over the whole pH traject, the ionic concentration and buffer capacity decrease whereas the electromigration dispersion strongly increases near the pI of histidine. I.e., that ampholytes can be applied as BGEs in CZE, however, just not at pH near their pI value, except as the difference between the pK values of the basic and acidic group, the deltapK value, is very small. For ampholytes with a low deltapK value or at high concentrations, all the before-mentioned effects are less fatal, but in that case we can not speak of a real low-conductivity BGE. If ampholytes are used at pH near their pK values, the use of ampholytes as BGE is not advantageously compared with simple weak bases and acids. This has been confirmed by calculations and experiments.  相似文献   

5.
Transient ITP (t-ITP) has been used in carrier ampholyte-based CE (CABCE) to enhance the sensitivity of protein analysis. The characteristics of carrier ampholytes (CAs) narrow pH cuts-based buffers, when used as BGEs in CE are compatible with t-ITP requirements. Indeed, being the sole buffering species of such solutions, CAs impose a pH close to their pI. Thus, in these solutions, the CAs possess low electrophoretic mobility. As a consequence, by adding an ionic component with high electrophoretic mobility either in the studied sample or in the BGE, a t-ITP step can be generated. This has first been demonstrated for protein test mixtures. Then, the combination of t-ITP with CABCE has been applied to study a real sample, the bovine milk.  相似文献   

6.
Phycoerythrin, ferritin, urease, beta-galactosidase and thyroglobulin, with molecular masses in excess of 200 kDa, adsorb and consequently fail to migrate to, and focus at, their pI positions in electrofocusing in immobilized pH gradients at a total Immobiline concentration of 20 mM while they do focus normally in pH gradients formed by carrier ampholytes. The addition of carrier ampholytes (pH range 3.5-9.5) at concentrations of 0.1 to 5% to the Immobiline-containing gels reduces adsorption (desorbs) some but not all of the 5 proteins at specific Immobiline concentrations. The adsorption is not due to water redistribution and consequent reduction in gel porosity; nor is it due to conductivity minima across the pH gradient. The hypothesis that the presence of oligomeric Immobiline contributed to the protein adsorption is the subject of the accompanying report.  相似文献   

7.
Sample adsorption to the inner surface of fused silica capillaries is a common problem in CE when analyzing macromolecules and is harmful to the analysis. We previously utilized the pH hysteresis effect of fused silica to facilitate electrophoresis of the strongly adsorbing protein β(2) gpI in plain-fused silica capillaries at neutral pH. In the present paper, the effect of different pretreatments of the capillary on the adsorption of the β(2) -glycoprotein I has been investigated using electroosmosis markers, SDS mobilization, and imaging based on indirect immunofluorescence microscopy for direct visualization. The amount of β(2) gpI adsorbed on the surface was probed using all these independent techniques after electrophoresis at neutral pH on capillaries pretreated with HCl, background electrolyte (BGE), and NaOH. BGE pretreatment was included as a positive control. We found that 80% or more of the starting material was adsorbed to the inner surface of the silica capillaries during electrophoresis after pretreatment with only BGE or with NaOH, but after acidic pretreatment the loss was consistently less than 20%. NaOH most efficiently removes adsorbed protein between runs. A theoretical calculation of the pH change of the BGE showed that electrolysis affects the pH more than the deprotonation of silanols during electrophoresis. We conclude that acidic pretreatment of fused silica capillaries diminishes adsorption of β(2) gpI by decreasing charge-dependent wall adsorption.  相似文献   

8.
Carrier ampholyte-based capillary electrophoresis (CABCE) has recently been introduced as an alternative to CE (CZE) in the classical buffers. In this study, isoelectric BGEs were obtained by fractionation of Servalyt pH 4-9 carrier ampholytes to cuts of typical width of 0.2 pH unit. CABCE feasibility was examined on a series of insect oostatic peptides, i.e. proline-rich di- to decapeptides, and phosphinic pseudopeptides--tetrapeptide mimetics synthesized as a mixture of four diastereomers having the -P(O)(OH)-CH(2)- moiety embedded into the peptide backbone. With identical selectivity, the separation efficiency of CABCE proved to be as good as classical CE for the insect oostatic peptides and better for diastereomers of the phosphinic pseudopeptides. In addition, despite the numerous species present in the narrow pH cuts of carrier ampholytes, CABCE seems to be free of system zones that could hamper the analysis. Peak symmetry was good for moderately to low mobile peptides, whereas some peak distortion due to electromigration dispersion, was observed for short peptides of rather high mobility.  相似文献   

9.
毛细管区带电泳法研究肾上腺素类药物的手性分离   总被引:9,自引:1,他引:8  
使用β-环糊精(β-CD)及β-CD-羧甲基(CM-β-CD)作为手性选择剂,采用毛细管区带电泳法(CZE)对去甲肾上腺素、肾上腺素和异丙肾上腺素的手性分离进行了研究。对影响这类药物手性分离的主要因素〔手性选择剂、背景电解质(BGE)、分离体系的酸度和温度〕进行了讨论,并对手性识别机理进行了探讨。  相似文献   

10.
Lalwani S  Tutu E  Vigh G 《Electrophoresis》2005,26(13):2503-2510
Ampholytes with close pK(a) values (i.e., good carrier ampholytes (CAs)) are needed as buffers in pH-biased isoelectric trapping (IET) separations. The syntheses of two families of such good CAs were reported recently. Members of the family of diamino sulfate ampholytes (first series) had pI values in the 5.7 < pI < 9.0 range. Members of the family of quaternary ammonium dicarboxylic acid ampholytes (second series) had pI values in the pI < 4.3 range. To further characterize the diamino sulfate ampholytes, their effective mobilities were measured by indirect UV-absorbance detection capillary electrophoresis in a series of background electrolytes (BGEs) with different pH values. The pK(a) and limiting ionic mobility values of the CAs were obtained by fitting these mobility values, as a function of the pH and the ionic strength of the BGEs, to the theoretical mobility expression. These diamino sulfates complete the list of CAs suitable for IET separations.  相似文献   

11.
We quantify the adsorption and desorption of a monoclonal immunoglobulin-G antibody, rituxamab (RmAb), on silica capillary surfaces using electrospray-differential mobility analysis (ES-DMA). We first develop a theory to calculate coverages and desorption rate constants from the ES-DMA data for proteins adsorbing on glass capillaries used to electrospray protein solutions. This model is then used to study the adsorption of RmAb on a bare silica capillary surface. A concentration-independent coverage of ≈4.0 mg/m(2) is found for RmAb concentrations ranging from 0.01 to 0.1 mg/mL. A study of RmAb adsorption to bare silica as a function of pH shows maximum adsorption at its isoelectric point (pI of pH 8.5) consistent with literature. The desorption rate constants are determined to be ≈10(-5) s(-1), consistent with previously reported values, thus suggesting that shear forces in the capillary may not have a considerable effect on desorption. We anticipate that this study will allow ES-DMA to be used as a "label-free" tool to study adsorption of oligomeric and multicomponent protein systems onto fused silica as well as other surface modifications.  相似文献   

12.
We prepared a series of low-molecular-mass fluorescent ampholytes with narrow pI range. These fluorescein-based ampholytes are detection compatible with argon laser-induced fluorescence (LIF) detection. The selected properties, important for their routine use as fluorescent pI markers, were examined. The pI values of new fluorescein-based pI markers were determined by capillary isoelectric focusing (CIEF) using currently available low-molecular-mass pI markers for CIEF with photometric detection. The examples of CIEF with fluorometric detection of new compounds together with fluorescein isothiocyanate (FITC) derivatized proteins are presented.  相似文献   

13.
We report on capillary isoelectric focusing-mass spectrometry (CIEF-MS) of complex peptide mixtures in the absence of carrier ampholytes. Furthermore, the use of low concentrations of carrier ampholytes as mere spacers is investigated. Carrier ampholytes are complex mixtures of amphoteric compounds with high buffering capacity. Since all peptides are amphoteric compounds by themselves, the use of carrier ampholytes may be superfluous to establish a stable pH gradient in CIEF analysis of protein digests. Our research showed that when carrier ampholytes are omitted, the analyte ions are not focused at their isoelectric point. The analytes are charged, leading to electrophoretic mobility uncharacteristic for CIEF. The method was tested for a five-protein-mixture at 0.02 mg/mL per protein and 0.05 mg/mL per protein. At the lower concentration, the analytes were stacked during the focusing process in only a limited length of the capillary. Therefore, the higher concentration led to better separation efficiency. It was found that at low concentration (0.20%) the carrier ampholytes could work as spacers. Though it led to sensitivity losses of 15-45%, this was compensated by the higher separation efficiencies seen. The method was evaluated with an eight-protein-mixture, of which all could be identified after performing MS/MS.  相似文献   

14.
The non-availability of commercial carrier ampholytes in the pH range greater than 11 has contributed to difficulties in focusing and resolving highly basic proteins/peptides using capillary isoelectric focusing (cIEF). Two different approaches, involving the use of N,N,N',N'-tetramethylethylenediamine (TEMED) and ampholyte 9-11, are investigated for their effects on the extension of separation range in cIEF. The addition of TEMED into pharmalyte 3-10 not only prevents the peptides/proteins from focusing in sections of the capillary beyond the detection point, but also extends the separation range to at least isoelectric point (pI) 12. The combination of ampholyte 9-11 with pharmalyte 3-10 surprisingly provides baseline resolution between bradykinin (pI 12) and cytochrome c (pI 10.3). The sample mixture, containing bradykinin, the high-pI protein calibration kit (pI 5.2-10.3), and cytochrome c digest, is employed to demonstrate the cIEF separation of proteins and peptides over a wide pH range of 3.7-12.  相似文献   

15.
Electrokinetic processes that lead to pH gradient instabilities in carrier ampholyte-based IEF are reviewed. In addition to electroosmosis, there are four of electrophoretic nature, namely (i) the stabilizing phase with the plateau phenomenon, (ii) the gradual isotachophoretic loss of carrier ampholytes at the two column ends in presence of electrode solutions, (iii) the inequality of the mobilities of positively and negatively charged species of ampholytes, and (iv) the continuous penetration of carbonate from the catholyte into the focusing column. The impact of these factors to cathodic and anodic drifts was analyzed by simulation of carrier ampholyte-based focusing in closed and open columns. Focusing under realistic conditions within a 5 cm long capillary in which three amphoteric low molecular mass dyes were focused in a pH 3–10 gradient formed by 140 carrier ampholytes was investigated. In open columns, electroosmosis displaces the entire gradient toward the cathode or anode whereas the electrophoretic processes act bidirectionally with a transition around pH 4 (drifts for pI > 4 and pI < 4 typically toward the cathode and anode, respectively). The data illustrate that focused zones of carrier ampholytes have an electrophoretic flux and that dynamic simulation can be effectively used to assess the magnitude of each of the electrokinetic destabilizing factors and the resulting drift for a combination of these effects. Predicted drifts of focused marker dyes are compared to those observed experimentally in a setup with coated capillary and whole column optical imaging.  相似文献   

16.
Colored, low molecular weight pI markers have been developed for isoelectric focusing (IEF) in acidic pH range. Their isoelectric points (pIs) were determined by direct measurement of the pH of the focused bands after completion of IEF on polyacrylamide gels. The practicable suitability of the proposed pI markers as pI standards for IEF was tested by applying gel IEF. The acidic pH gradient was created either by commercial synthetic carrier ampholytes or by mixture of simple buffers consisting of acids (non-ampholytes) and ampholytic buffers. By applying simple acids, it was possible to extend the acidic pH range beyond those achievable with commercial synthetic carrier ampholytes. By using an experimental arrangement without electrode electrolyte reservoirs with electrodes creating the fixed end of the gel, the strongly acidic pH gradient was stable even for prolonged focusing time.  相似文献   

17.
Capillary isoelectric focusing hyphenated with mass spectrometry detection, following the sequential injection of the carrier ampholytes and the sample zone, is highly efficient for the characterization of proteins. The main advantage of the sequential injection protocol is that ampholytes, with pH ranges, which are not supposed to cover the isoelectric points of the sample components, can be used for separation. The method then allows online mass spectrometry detection of separated analytes either in the absence (substances that have left the pH gradient) or in the presence of low‐level ampholytes (substances that are migrating within the pH gradient). The appearance of the substances within, or outside the pH gradient depends on, e.g., the composition of the ampholytes (broad or narrow pH range) or on the composition of electrolyte solutions. The experiments performed in coated capillaries (with polyvinyl alcohol or with polyacrylamide) show that the amount and the injection length of the ampholytes influence the length of the pH gradient formed in the capillary.  相似文献   

18.
Sixteen peptides (trimers to hexamers) were designed for use as a set of pI markers for capillary isoelectric focusing (CIEF). Each peptide contains one tryptophan residue for detection by UV absorption and other amino acid residues having ionic side chains, which are responsible for focusing to its pI. The pIs of these peptides were determined by slab-gel IEF using commercial carrier ampholytes. The focused peptides in the gel were detected by absorption measurement at 280 nm using a scanning densitometer and the pH gradient was determined by measuring the pH of the gel using an oxidized metal membrane electrode. The pI values of the peptides ranged from 3.38 to 10.17. The obtained values agreed well with the predicted ones, which were calculated based on amino acid compositions, with root mean square differences of 0.15 pH unit. The peptides were detected at 280 nm as very sharp peaks when separated by CIEF. The pI values of some standard proteins were redetermined by CIEF by using this set of peptide pI markers and the values agreed closely with those reported previously. The sharp focusing, stability, high purity and high solubility of these synthetic pI markers should facilitate the profiling of a pH gradient in a capillary and the determination of the pI values of proteins.  相似文献   

19.
Narrow pH cuts of carrier ampholytes (CAs), originally designed for IEF, have been used as BGEs in CE. Their physicochemical properties, rather high buffering capacity and low conductivity, allow very efficient protein separations under high electric field strength. Due to their isoelectric properties, CA BGEs are expected to present a low ionic concentration and consequently a low loading capacity. In this study, we developed a simple method that allows the estimation of the loading capacity of a UV-absorbing BGE by CE. We first characterized in terms of loading capacity, classical ammediol-chromate UV-absorbing BGEs and a 10 mM histidine solution, a classical isoelectric buffer. Then, the loading capacity of four different CA-based BGEs has been assessed. Experimental results have shown that the CA-based buffers were presenting a rather high loading capacity, comparable to classical buffer ones and far higher than the one of the 10 mM histidine solution.  相似文献   

20.
The paper reports the results of a study carried out to evaluate the use of three 1‐alkyl‐3‐methylimidazolium‐based ionic liquids as non‐covalent coating agents for bare fused‐silica capillaries and additives of the electrolyte solutions (BGE) for CE of basic proteins in the co‐EOF separation mode. The three ionic liquids are differentiated from each other by the length of the alkyl group on the imidazolium cation, consisting of either an ethyl, butyl or octyl substituent, whereas tetrafluoroborate is the common anionic component of the ionic liquids. Coating the capillary with the ionic liquid resulted in improved peak shape and protein separation, while the EOF was maintained cathodic. This indicates that each ionic liquid is effective at masking the protein interaction sites on the inner surface of the capillary, also when its adsorption onto the capillary wall has not completely neutralized all the negative charges arising from the ionization of the silanol groups and the ionic liquid is not incorporated into the BGE employed for separation. Using the coated capillaries with BGE containing the ionic liquid employed for the coating, at concentration low enough to maintaining the EOF cathodic, both peak shape and protein separation varied to different extents, based on the particular ionic liquid used and its concentration. Fast and efficient separation of the model basic protein mixture in co‐electroosmotic CE is obtained with the 1‐butyl‐3‐methylimidazolium tetrafluoroborate coated capillary and 100 mM acetate buffer (pH 4.0) containing 4.4 mM 1‐butyl‐3‐methylimidazolium tetrafluoroborate as the BGE.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号