首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The present work describes the development of a selective and sensitive voltammetric sensor for simultaneous determination of catechol (CC) and hydroquinone (HQ), based on a glassy carbon (GC) electrode modified with manganese phthalocyanine azo‐macrocycle (MnPc) adsorbed on multiwalled carbon nanotubes (MWCNT). Scanning electron microscopy and scanning electrochemical microscopy were used to characterize the composite material (MnPc/MWCNT) on the glassy carbon electrode surface. The modified electrode showed excellent electrochemical activity towards the simultaneous oxidation and reduction of CC and HQ. On the MnPc/MWCNT/GC electrode, both CC and HQ can generate a pair of quasi‐reversible and well‐defined redox peaks. Under optimized experimental and operational conditions, the cathodic peak currents were linear over the range 1–600 µmol L?1 for both CC and HQ, with limits of detection of 0.095 and 0.041 µmol L?1, respectively. The anodic peak currents were also linear over the range 1–600 µmol L?1 for both CC and HQ, with limits of detection of 0.096 and 0.048 µmol L?1, respectively. The proposed method was effectively applied for the simultaneous detection of hydroquinone and catechol in water samples and the results were in agreement with those obtained by a comparative method described in the literature.  相似文献   

2.
《Electroanalysis》2004,16(20):1697-1703
An amperometric glucose biosensor based on multi‐walled carbon nanotube (MWCNT) modified glassy carbon electrode has been developed. MWCNT‐modified glassy carbon electrode was obtained by casting the electrode surface with multi‐walled carbon nanotube materials. Glucose oxidase was co‐immobilized on the MWCNT‐modified glassy carbon surface by electrochemical deposition of poly(o‐phenylenediamine) film. Enhanced catalytic electroreduction behavior of oxygen at MWCNT‐modified electrode surface was observed at a potential of ?0.40 V (vs. Ag|AgCl) in neutral medium. The steady‐state amperometric response to glucose was determined at a selected potential of ?0.30 V by means of the reduction of dissolved oxygen consumed by the enzymatic reaction. Common interferents such as ascorbic acid, 4‐acetamidophenol, and uric acid did not interfere in the glucose determination. The linear range for glucose determination extended to 2.0 mM and the detection limit was estimated to be about 0.03 mM.  相似文献   

3.
The electrochemical oxidation of naproxen was investigated at a multiwalled carbon nanotube (MWCNT)‐modified electrode. A decrease (200 mV) in the overpotential of the naproxen oxidation reaction and considerable (4‐fold) current increase (compared to the bare glassy‐carbon electrode) was observed. Two one‐electron transfers were verified at both bare and MWCNT‐modified electrodes and thus a new mechanism for the electrochemical oxidation of naproxen is proposed. Indicative of a mass transport regime that includes a thin‐layer diffusional process (entrapment of naproxen species within the MWCNT film) is presented as a possible explanation for the lowered oxidation potential and substantial current increase. The anti‐fouling properties of MWCNTs on the amperometric detection of naproxen using a batch‐injection analysis (BIA) system is demonstrated.  相似文献   

4.
An electrochemical sensor has been developed for the determination of the herbicide bentazone, based on a GC electrode modified by a combination of multiwalled carbon nanotubes (MWCNT) with β‐cyclodextrin (β‐CD) incorporated in a polyaniline film. The results indicate that the β‐CD/MWCNT modified GC electrode exhibits efficient electrocatalytic oxidation of bentazone with high sensitivity and stability. A cyclic voltammetric method to determine bentazone in phosphate buffer solution at pH 6.0, was developed, without any previous extraction, clean‐up, or derivatization steps, in the range of 10–80 µmol L?1, with a detection limit of 1.6 µmol L?1 in water. The results were compared with those obtained by an established HPLC technique. No statistically significant differences being found between both methods.  相似文献   

5.
A sensitive electroanalytical method is presented for the determination of 4‐hexylresorcinol using adsorptive stripping voltammetry (AdsSV) at a multiwalled carbon nanotube modified basal plane pyrolytic graphite electrode (MWCNT‐BPPGE). This method is also extended to the use of a MWCNT modified screen‐printed electrode (MWCNT‐SPE), thereby demonstrating that this approach can easily be incorporated into a facile and inexpensive electrochemical sensor.  相似文献   

6.
The electrochemical detection of carbaryl at low potentials, in order to avoid matrix interferences, is an important challenge. This study describes the development, electrochemical characterization and utilization of a glassy carbon (GC) electrode modified with multi-wall carbon nanotubes (MWCNT) plus cobalt phthalocyanine (CoPc) for the quantitative determination of carbaryl in natural waters. The surface morphology was examined by scanning electron microscopy, enhanced sensitivity was observed with respect to bare glassy carbon and electrocatalytic effects reduced the oxidation potential to +0.80 V vs. SCE in acetate buffer solution at pH 4.0. Electrochemical impedance spectroscopy was used to estimate the rate constant of the oxidation process and square-wave voltammetry to investigate the effect of electrolyte pH. Square-wave voltammetry in acetate buffer solution at pH 4.0, allowed the development of a method to determine carbaryl, without any previous step of extraction, clean-up, or derivatization, in the range of 0.33-6.61 μmol L−1, with a detection limit of 5.46 ± 0.02 nmol L−1 (1.09 ± 0.02 μg L−1) in water. Natural water samples spiked with carbaryl and without any purification step were successfully analyzed by the standard addition method using the GC/MWCNT/CoPc film electrode.  相似文献   

7.
A new sensor based on the grafting of 4‐tert‐butylcatechol on the surface of a glassy carbon electrode (GC) was developed for the catalytic oxidation of homocysteine ( Hcy ). The GC‐modified electrode exhibited a reversible redox response at neutral pH. Under the optimum conditions cyclic voltammetric results indicated the excellent electrocatalytic activity of modified electrode toward the oxidation of Hcy at reduced over‐potential about 350 mV. A linear dynamic range of 0.01–3.0 mM and a detection limit of 1.0 µM were obtained for Hcy . The modified electrode was used as an electrochemical sensor for selective determination of Hcy in human blood.  相似文献   

8.
《Electroanalysis》2017,29(4):1049-1055
A sensitive electrochemical method for the determination and quantification of curcumin using adsorptive stripping voltammetry (AdsSV) at a multiwalled carbon nanotube modified basal plane pyrolytic graphite electrode (MWCNT‐BPPG electrode) is presented exploiting the high surface area of the latter. Next the voltammetric behaviour of curcumin on the modified electrode is examined and AdsSV shown to be a sensitive method for quantifying curcumin. The adsorption of curcumin on the electrode surface is evidenced to follow a Langmuir adsorption isotherm. Linear calibration for curcumin in the range of 2–100 μM was obtained with a detection limit of 0.45 μM and a limit of quantification of 1.49 μM. For application to real samples of turmeric, a one‐step sample preparation in ethanol has developed providing a simple and rapid extraction procedure. The MWCNT‐BPPG electrode with AdsSV allowed the determination of curcumin equivalent in turmeric powder sample with recoveries in the range of 92–108 %. This facile and fast method will be useful for monitoring the quality of curcumin containing in commercial turmeric products.  相似文献   

9.
A new electrochemical methodology has been developed for the detection of ozone using multiwalled carbon nanotubes (MWCNT). The method presented here is based on the reaction of ozone with indigo blue dye producing anthranilic acid (ATN). The electrochemical profile of ATN on an electrode of glassy carbon (GC) modified with MWCNT showed an oxidation peak potential at 750 mV vs. Ag/AgCl. An analytical method was developed using differential pulse voltammetry (DPV) to determine ATN in a range of 50–400 nmol L?1, with a detection limit of 9.7 nmol L?1. Ozonated water samples were successfully analyzed by GC/MWCNT electrode and the recovery procedure yielded values between of 96.5 and 102.3 %.  相似文献   

10.
《Electroanalysis》2018,30(5):877-885
This work describes for the first time the employment of water soluble GSH‐ZnSe QDs stabilized by XG and MWCNT for electrode modification in the detection of Cd ions in a highly sensitive and selective manner resulting from the unique structure and surface chemistry of the used QDs. The surface of a glassy carbon (GC) electrode was modified through casting a thin layer of multiwalled carbon nanotubes (MWCNT) followed by a complex layer of ZnSe quantum dots (QDs) stabilized by xanthan gum (XG). Due to the electrocatalytic properties of MWCNT and electroanalytical performance of ZnSe‐XG complex, the new modified electrode significantly improves the sensitivity and selectivity of Cd(II) detection and exhibits enhanced performance in comparison to bare GC, ZnSe/GC and ZnSe/MWCNT/GC electrodes. Strong interactions between ZnSe QDs and XG resulting from hydrogen bonding and complexing association led to stabilization of ZnSe QDs and higher affinity towards Cd(II) ions adsorption compared to a ZnSe QDs film alone. The modified electrode showed linear response in a wide concentration range from 100 nM to 5 μM (R2=0.9967) along with a high sensitivity of 156.6 nA ⋅ mol−1 ⋅ L−1 and a low detection limit of 20 nM. The electrode shows high selectivity to Cd with negligible interference from other metal ions and salts.  相似文献   

11.
An electrochemical method for the determination of tripelennamine hydrochloride (TPA) using cetyltrimethylammoniumbromide‐multiwalled carbon nanotubes modified glassy carbon electrode (MWCNT‐CTAB/GCE) was developed. Because of good electrical conductivity of MWCNT and catalytic behavior of CTAB, new electrode significantly enhances the sensitivity for the detection of TPA. Parameters such as amount of modifier suspension, scan rate, pH of measure solution, heterogeneous rate constant were investigated. The electrode exhibits a linear potential response in the range of 1.0×10?8 M to 3.0×10?6 M with a detection limit of 2.38× 10?9 M. The modified electrode was successfully applied to the determination of TPA in pharmaceutical and real samples.  相似文献   

12.
We report the electrochemical behavior of a 4‐nitroimidazole derivative, 1‐methyl‐4‐nitro‐2‐hydroxymethylimidazole (4‐NImMeOH), on glassy carbon electrode (GCE) modified with multiwalled carbon nanotubes (MWCNT). As dispersing agents, dimethylformamide (DMF) and water were used. The electrochemical response of the resulting electrodes was evaluated using linear sweep, cyclic and square‐wave voltammetry (LSV, CV and SWV). Several parameters such as medium pH, nature and concentration of the CNTs dispersion and accumulation time were tested. The optimal conditions determined for obtain better response were: pH 2, dispersion concentration=4 mg/mL of CNT in water, accumulation time=7 min. The MWCNT‐modified GCE exhibited attractive electrochemical properties producing enhanced currents with a significant reduction in the overpotential and good signal‐to‐noise characteristics, in comparison with the bare GCE. The modified electrode is highly repeatable for consecutive measurements, reaching a variation coefficient of 2.9% for ten consecutive runs.  相似文献   

13.
We report a simple and effective strategy for fabrication of the nanocomposite containing chitosan (CS) and multiwall carbon nanotube (MWNT) coated on a glassy carbon electrode (GCE). The characterization of the modified electrode (CS‐MWNT/GC) was carried out using scanning electron microscopy (SEM) and UV–vis absorption spectroscopy. The electrochemical behavior of CS‐MWNT/GC electrode was investigated and compared with the electrochemical behavior of chitosan modified GC (CS/GC), multiwalled carbon nanotube modified GC (MWNT/GC) and unmodified GC using cyclic voltammetry (CV) and electron impedance spectroscopy (EIS). The chitosan films are electrochemically inactive; similar background charging currents are observed at bare GC. The chitosan films are permeable to anionic Fe(CN)63?/4? (FC) redox couple. Electrochemical parameters, including apparent diffusion coefficient for the Fe(CN)63?/4? redox probe at FC/CS‐MWNT/GC electrode is comparable to values reported for cast chitosan films. This modified electrode also showed electrocatalytic effect for the simultaneous determination of D‐penicillamine (D‐PA) and tryptophan (Trp). The detection limit of 0.9 μM and 4.0 μM for D‐PA and Trp, respectively, makes this nanocomposite very suitable for determination of them with good sensitivity.  相似文献   

14.
A hexagonal mesoporous silica (HMS) modified carbon paste electrode (CPE) was fabricated and characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) methods (ferrocene as a probe). The electrochemical behavior of nitrophenol (o‐NP) at the HMS modified electrode (HMSCPE) was investigated. Compared with CPE, a well‐defined reduction peak and a remarkably peak current response was observed. It is indicated that mesoporous HMS exhibited remarkable enhancement effects on the electrochemical reduction of o‐NP. The electrochemical reduction mechanism was also discussed. Consequently, a simple and sensitive electrochemical method was proposed for the determination of o‐NP, which was used to determine o‐NP in waste water samples.  相似文献   

15.
The voltammetric behavior of dopamine (DA) and uric acid (UA) on a gold electrode modified with self‐assembled monolayer (SAM) of cysteamine (CA) conjugated with functionalized multiwalled carbon nanotubes (MWCNTs) was investigated. The film modifier of functionalized SAM was characterized by means of scanning electron microscopy (SEM) and also, electrochemical impedance spectroscopy (EIS) using para‐hydroquinone (PHQ) as a redox probe. For the binary mixture of DA and UA, the voltammetric signals of these two compounds can be well separated from each other, allowing simultaneous determination of DA and UA. The effect of various experimental parameters on the voltammetric responses of DA and UA was investigated. The detection limit in differential pulse voltammetric determinations was obtained as 0.02 µM and 0.1 µM for DA and UA, respectively. The prepared modified electrode indicated a stable behavior and the presence of surface COOH groups of the functionalized MWCNT avoided the passivation of the electrode surface during the electrode processes. The proposed method was successfully applied for the determination of DA and UA in urine samples with satisfactory results. The response of the gold electrode modified with MWCNT‐functionalized SAM method toward DA, UA, and ascorbic acid (AA) oxidation was compared with the response of the modified electrode prepared by the direct casting of MWCNT.  相似文献   

16.
《Electroanalysis》2018,30(2):238-249
A copper nano particles and cerium (IV) oxide modified carbon nanotube based composite on glassy carbon electrode (Cu−CeO2/MWCNT/GCE) was fabricated for simultaneous determination of guanine and adenine. The surface morphology, chemistry and conductance of the prepared electrodes were characterized by scanning electron microscopy (SEM), energy dispersion X‐ray (EDX), X‐Ray photoelectron spectroscopy (XPS) and electrochemical impedance spectroscopy (EIS). The Cu−CeO2/MWCNT/GCE improved electrochemical behaviour of guanine and adenine compared to other electrodes. The modified electrode was also used for individual and simultaneous determination of guanine and adenine. Under optimized conditions, the calibration curves were obtained linearly in the range of 0.20 to 6.00 μM for the guanine and 0.10 to 8.0 μM for the adenine by differential pulse voltammetry. The limits of detection of guanine and adenine were calculated as 0.128 and 0.062 μM, respectively. Interferences studies were also performed in the presence of inorganic and organic compounds. Moreover, the determination of guanine and adenine contents were carried out in a calf thymus DNA sample by the developed method with satisfactory results.  相似文献   

17.
《Electroanalysis》2017,29(12):2780-2787
para‐Nitrophenol (p‐NP) is a high priority environmental pollutant. For the sake of safety, sensitive detection of its presence in water resources and food is highly important. The present article describes the use of copper metal nanoparticles for selective and sensitive electrochemical detection of p‐NP in pure and real sample. For this the gold electrode was fabricated by polyvenylpyrrolidone stabilized copper metal nanoparticles (ca . 4 nm d.) via self‐assembled 4,4′‐bipyridine monolayer and characterized by microscopic and electrochemical techniques. The newly developed sensor permits for sensitive detection of p‐NP in a linear concentration range of 1–500 μM with lowest detection limit of 0.34 nM and high sensitivities 247.1 μA cm−2 μM−1. The sensor electrode exhibited high stability, reproducibility, good selectivity in the presence of potential interfering agents and had an excellent capability for the selective determination of p‐NP in river water without preliminary treatments.  相似文献   

18.
《Analytical letters》2012,45(11):2151-2160
Abstract

The electrochemical behavior of Cu(II) was investigated on three‐dimensional 3‐mercaptopropionic acid (MPA) assembled on gold nanoparticle‐modified glassy carbon (GNP/GC) electrode. The results demonstrated that the MPA monolayer inhibited the charging current while promoted the response of accumulated Cu(II) on GNP/GC electrode. The effects of pH, scan rate, and accumulation time on the voltammetric behavior of Cu(II) on the MPA/GNP/GC electrode were studied. The MPA modified electrode presented a voltammetric response linearly proportional to the Cu(II) concentration from 0.1 µg/l to 100 µg/l, with a detection limit of 3.2 ng/l. Moreover, this electrode was successfully applied to the determination of Cu(II) in tap water.  相似文献   

19.
Shahrokhian S  Rastgar S 《The Analyst》2012,137(11):2706-2715
Mixtures of gold-platinum nanoparticles (Au-PtNPs) are fabricated consecutively on a multi-walled carbon nanotubes (MWNT) coated glassy carbon electrode (GCE) by the electrodeposition method. The surface morphology and nature of the hybrid film (Au-PtNPs/MWCNT) deposited on glassy carbon electrodes is characterized by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD), electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) techniques. The modified electrode is used as a new and sensitive electrochemical sensor for the voltammetric determination of cefotaxime (CFX). The electrochemical behavior of CFX is investigated on the surface of the modified electrode using linear sweep voltammetry (LSV). The results of voltammetric studies exhibited a considerable improvement in the oxidation peak current of CFX compared to glassy carbon electrodes individually coated with MWCNT or Au-PtNPs. Under the optimized conditions, the modified electrode showed a wide linear dynamic range of 0.004-10.0 μM with a detection limit of 1.0 nM for the voltammetric determination of CFX. The modified electrode was successfully applied for the accurate determination of trace amounts of CFX in pharmaceutical and clinical preparations.  相似文献   

20.
We present here a simple procedure for the determination of mercury(II) using differential pulse anodic stripping voltammetry (DPASV) at palladium particles‐impregnated natural phosphate modified carbon paste electrodes (Pd‐NP‐CPE). The surface of modified electrode was characterized using SEM, infrared spectroscopy, X‐ray diffraction and electrochemical analysis. All experimental variables involved in the voltammetric stripping method were optimized. The detection limit was found to be 4.99×10?8 mol L?1 (S/N=3) that is not different to the permitted value for Hg(II) in water reported by the Environmental Protection Agency (EPA). The proposed electrode exhibits good applicability for monitoring Hg(II) in tap and wastewater.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号