首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A fast and simple technique composed of dispersive liquid–liquid microextraction (DLLME) and online preconcentration MEKC with diode array detection was developed for the determination of four phenoxyacetic acids, 2,4,5‐trichlorophenoxyacetic acid, 2,4‐dichlorophenoxyacetic acid, 2,6‐dichlorophenoxyacetic acid, and 4‐chlorophenoxyacetic acid, in drinking water. The four phenoxyacetic acids were separated in reversed‐migration MEKC to the baseline. About 145‐fold increases in detection sensitivity were observed with online concentration strategy, compared with standard hydrodynamic injection (5 s at 25 mbar pressure). LODs ranged from 0.002 to 0.005 mg/L using only the online preconcentration procedures without any offline concentration of the extract. A DLLME procedure was used in combination with the proposed online preconcentration strategies, which achieved the determination of analytes at limits of quantification ranging from 0.2 to 0.5 μg/kg, which is far lower than the maximum residue limits established by China. The satisfactory recoveries obtained by DLMME spiked at two levels ranged from 67.2 to 99.4% with RSD <15%, making this proposed method suitable for the determination of phenoxyacetic acids in water samples.  相似文献   

2.
Dispersive liquid–liquid microextraction has been proposed as an extraction technique combined with micellar electrokinetic chromatography (MEKC) for the analysis of eight 5‐nitroimidazole compounds, including some metabolites, in water samples. Determination has been carried out using a diode array detector, employing 20 mM sodium phosphate and 150 mM SDS as separation buffer. Separation has taken place under a voltage of 25 kV and a temperature of 20°C. Samples were prepared in a buffer without micelles and they were hydrodynamically injected at 50 mbar for 25 s, producing a sweeping effect on the analytes for increasing sensitivity. Different factors involved in the dispersive liquid–liquid microextraction procedure were optimized, such as sample pH, nature, and volume of extraction and dispersive solvents in the mixture, percentage of NaCl added to sample and shaking time after the injection of the extraction and dispersive solvents. The method was characterized for water samples, achieving detection limits lower than 2.4 μg/L. Trueness was checked in river, tap, and bottled water. Dispersive liquid–liquid microextraction combined with MEKC constitutes an easy, cheap, and green alternative for 5‐nitroimidazole analysis in environmental water samples.  相似文献   

3.
A simple, fast, sensitive and reproducible micellar electrokinetic chromatography (MEKC)–UV method for the determination of nikethamide (NKD) in human urine and pharmaceutical formulation has been developed and validated. The method exhibits high trueness, good precision, short analysis time and low reagent consumption. NKD is an organic compound belonging to the psychoactive stimulants used as an analeptic drugs. The proposed analytical procedure consists of few steps: dilution of urine or drug in distilled water, centrifugation for 2 min (12,000 g ), separation by MEKC and ultraviolet‐absorbance detection of NKD at 260 nm. The background electrolyte used was 0.035 mol/L pH 9 borate buffer with the addition of 0.05 mol/L sodium dodecyl sulfate and 6.5% ACN. Effective separation was achieved within 5.5 min under a voltage of 21 kV (~90 μA) using a standard fused‐silica capillary (effective length 51 cm, 75 μm i.d.). The determined limit of detection for NKD in urine was 1 μmol/L (0.18 μg/mL). The calibration curve obtained for NKD in urine showed linearity in the range 4–280 μmol/L (0.71–49.90 μg/mL), with R2 0.9998. The RSD of the points of the calibration curve varied from 5.4 to 9.5%. The analytical procedure was successfully applied to analysis of pharmaceutical formulation and spiked urine samples from healthy volunteers.  相似文献   

4.
VH Springer  AG Lista 《Electrophoresis》2012,33(13):2049-2055
A method to determine four antibiotics for veterinary use (ciprofloxacin, enrofloxacin, florfenicol, and chloramphenicol) of different families (fluoroquinolones and amphenicols) in bovine milk was developed. The determination of the analytes was carried out using micellar electrokinetic capillary chromatography (MEKC) with a common sodium borate-SDS buffer solution containing single-walled carbon nanotubes (SWCNTs). In this way, a great improvement in the electrophoretic resolution and the separation efficiency was achieved compared to MEKC. An online reverse electrode polarity-stacking mode (REPSM) was carried out to enhance sensitivity. This step was performed in only 2 min and it allowed a stacked percentage of 103. That means that all the amount of injected analytes is effectively stacked. When this stacking procedure was combined with an off-line preconcentration step, based on SPE, analytes could be detected in lower concentration than the established maximum residue limits (MRLs). The LODs for the four compounds were between 6.8 and 13.8 μg L(-1) and the RSD values were between 1.1% and 6.6%. The whole method was applied to spiked real samples with acceptable precision and satisfactory recoveries.  相似文献   

5.
A micellar electrokinetic chromatography (MEKC) method for the simultaneous determination of the antiviral drugs acyclovir and valacyclovir and their major impurity, guanine, was developed. The influences of several factors (surfactant and buffer concentration, pH, applied voltage, capillary temperature and injection time) were studied. Using tyramine hydrochloride as internal standard, the analytes were all separated in about 4 min. The separation was carried out in reversed polarity mode at 28°C, 25 kV and using hydrodynamic injection (15 s). The separation was effected in a fused‐silica capillary 100 μm × 56 cm and a background electrolyte of 20 mM citric acid–1 M Tris solution (pH 2.75), containing 125 mM sodium dodecyl sulphate and detection at 254 nm. The method was validated with respect to linearity, limit of detection and quantification, accuracy, precision and selectivity. Calibration curves were linear over the range 0.1–1 μg/mL (guanine) and from 0.1 to 120 μg/mL for both valacyclovir and acyclovir. The relative standard deviations of intra‐ and inter‐day migration times and corrected peak areas were less than 5.0%. The proposed method was successfully applied to the determination of the analytes in tablets and creams. From the previous study it is concluded that the stability‐indicating method developed for acyclovir and valacyclovir can be used for analysis of the drug in various stability samples. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

6.
The applicability of an ionic liquid‐based cationic surfactant 1‐dodecyl‐3‐methyl‐imidazolium tetrafluoroborate (C12MImBF4) as pseudostationary phase in MEKC has been evaluated for the analysis of 11 carbamate pesticides (promecarb, carbofuran, metolcarb, fenobucarb, aldicarb, propoxur, asulam, benomyl, carbendazim, ethiofencarb, isoprocarb) in juice samples. Under optimum conditions (separation buffer, 35 mM NaHCO3 and 20 mM C12MImBF4, pH 9.0; capillary temperature 25°C; voltage –22 kV) the analysis was carried out in less than 12 min, using hydrodynamic injection (50 mbar for 7.5 s) and detection at 200 nm. For the extraction of these CRBs from juice samples, a dispersive liquid–liquid microextraction (DLLME) procedure has been proposed, by optimization of variables affecting the efficiency of the extraction. Following this treatment, sample throughput was approximately 12 samples per hour, obtaining a preconcentration factor of 20. Matrix‐matched calibration curves were established using tomato juice as representative matrix (from 5 to 250 μg/L for CBZ, BY, PX, CF, FEN, ETH, ISP, and 25–250 μg/L for ASL, ALD, PRC, MTL), obtaining quantification limits ranging from 1 to 18 μg/L and recoveries from 70 to 96%, with RSDs lower than 9%.  相似文献   

7.
This article reports a new procedure for the direct determination of faecal sterols coprostanol and cholesterol in wastewater samples as tracers of human sewage contamination. The method combines in-tube solid-phase microextraction (IT-SPME) for analyte enrichment and capillary liquid chromatography (LC) for separation with diode array detection for identification and quantification. A titania-based polymeric capillary column and a conventional octadecyl silica (ODS) capillary column were evaluated and compared for their ability to separate the analytes. The titania-based column allowed the separation of the analytes in much shorter chromatographic times and with better chromatographic profiles, which in turn resulted in better detectability. In addition, IT-SPME allowed the direct injection into the chromatographic system of sample volumes as large as 200 μL, thus making unnecessary off-line clean-up and concentration steps. In such a way, the tested compounds could be directly analysed in less than 10 min, the limits of detection (LODs) being 10 and 1.2 μg/L for coprostanol and cholesterol, respectively. The reliability of the proposed method was tested by processing several wastewater samples.  相似文献   

8.
A three‐phase hollow‐fiber liquid‐phase microextraction combined with a capillary LC method using diode array detection was proposed for the determination of six sulfonylurea herbicides, triasulfuron, metsulfuron‐methyl, chlorsulfuron, flazasulfuron, chlorimuron‐ethyl, and primisulfuron‐methyl, in environmental water samples. Different factors that can affect the extraction process such as extraction solvent, acidity of the donor phase, composition and pH of the acceptor phase, salt addition, stirring speed, and extraction time were optimized. Under the optimum conditions, detection and quantitation limits between 0.1 – 1.7 and 0.3 – 5.7 μg/L, respectively, and enrichment factors ranging from 71 to 548 were obtained. The calibration curves were linear within the range of 0.3 – 40 μg/L. Intra‐ and interday RSDs were <6.3 and 8.4%, respectively. The relative recoveries of the spiked ground and river water samples were in the range of 69.4 – 119.2 and 77.4 – 111.7%, respectively. The results of the study revealed that the developed methodology involves an efficient sample pretreatment allowing the preconcentration of analytes, combined with the use of a miniaturized separation technique, suitable for the accurate determination of sulfonylurea herbicides in water.  相似文献   

9.
A method based on poly (methacrylic acid‐co‐ethylene glycol dimethacrylate) monolith microextraction and octadecylphosphonic acid‐modified zirconia‐coated CEC followed by field‐enhanced sample injection preconcentration technique was proposed for sensitive CE‐UV analysis of six antidepressants (doxepin, clozapine, imipramine, paroxetine, fluoxetine and chlorimipramine) in human plasma and urine. A poly(methacrylic acid‐co‐ethylene glycol dimethacrylate) monolithic capillary column was introduced for the extraction of antidepressants from urine and plasma samples. The hydrophobic main chains and acidic pendant groups of the monolithic column make it a superior material for extraction of basic analytes from aqueous matrix. After extraction, the desorption solvent, which normally provided an excellent medium to ensure direct compatibility for field‐enhanced sample injection in CE, was analyzed by CE directly. By the use of alkylphosphonate‐modified zirconia‐coated CEC for separation of the basic compounds of antidepressants, high separation efficiency and resolution were achieved because that both hydrophobic interaction between analytes and alkylphosphonate‐modified zirconia coat and electrophoretic effect work on the separation of antidepressants. The best separation was achieved using a buffer composed of 0.3 M ammonium acetate (adjusted to pH 4.5 with 1 M acetic acid) and 35% ACN v/v, with a temperature and voltage of 20°C and 20 kV, respectively. By applying both preconcentration procedures, LODs of 11.4–51.5 and 3.7–17.0 μg/L were achieved for the six antidepressants in human plasma and urine, respectively. Excellent method of reproducibility was found over a linear range of 50–5000 μg/L in plasma and urine sample.  相似文献   

10.
A porous and highly efficient polyaniline‐based solid‐phase microextraction (SPME) coating was successfully prepared by the electrochemical deposition method. A method based on headspace SPME followed by HPLC was established to rapidly determine trace chlorophenols in water samples. Influential parameters for the SPME, including extraction mode, extraction temperature and time, pH and ionic strength procedures, were investigated intensively. Under the optimized conditions, the proposed method was linear in the range of 0.5–200 μg/L for 4‐chlorophenol and 2,4,6‐trichlorophenol, 0.2–200 μg/L for 2,4‐dichlorophenol and 2–200 μg/L for 2,3,4,6‐tetrachlorophenol and pentachlorophenol, with satisfactory correlation coefficients (>0.99). RSDs were <15% (n = 5) and LODs were relatively low (0.10–0.50 μg/L). Compared to commercial 85 μm polyacrylate and 60 μm polydimethylsiloxane/divinylbenzene fibers, the homemade polyaniline fiber showed a higher extraction efficiency. The proposed method has been successfully applied to the determination of chlorophenols in water samples with satisfactory recoveries.  相似文献   

11.
Solid‐phase extraction coupled with dispersive liquid–liquid microextraction was developed as an ultra‐preconcentration method for the determination of four organophosphorus pesticides (isocarbophos, parathion‐methyl, triazophos and fenitrothion) in water samples. The analytes considered in this study were rapidly extracted and concentrated from large volumes of aqueous solutions (100 mL) by solid‐phase extraction coupled with dispersive liquid–liquid microextraction and then analyzed using high performance liquid chromatography. Experimental variables including type and volume of elution solvent, volume and flow rate of sample solution, salt concentration, type and volume of extraction solvent and sample solution pH were investigated for the solid‐phase extraction coupled with dispersive liquid–liquid microextraction with these analytes, and the best results were obtained using methanol as eluent and ethylene chloride as extraction solvent. Under the optimal conditions, an exhaustive extraction for four analytes (recoveries >86.9%) and high enrichment factors were attained. The limits of detection were between 0.021 and 0.15 μg/L. The relative standard deviations for 0.5 μg/L of the pesticides in water were in the range of 1.9–6.8% (n = 5). The proposed strategy offered the advantages of simple operation, high enrichment factor and sensitivity and was successfully applied to the determination of four organophosphorus pesticides in water samples.  相似文献   

12.
A rapid and solvent‐free procedure for the determination of 4‐tert‐octylphenol and 4‐nonylphenol isomers in aqueous samples is described. The method involves in‐situ acetylation and microwave‐assisted headspace solid‐phase microextraction prior to their determination using gas chromatography–ion trap mass spectrometry operated in the selected ion storage mode. The dual experimental protocols to evaluate the effects of various derivatization and extraction parameters were investigated and the conditions optimized. Under optimized conditions, 300 μL of acetic anhydride mixed with 1 g of potassium hydrogencarbonate and 2 g of sodium chloride in a 20 mL aqueous sample were efficiently extracted by a 65 μm polydimethylsiloxane‐divinylbenzene fiber that was located in the headspace when the system was microwave irradiated at 80 W for 5 min. The limits of quantitation were 5 and 50 ng/L for 4‐tert‐octylphenol and 4‐nonylphenol isomers, respectively. The precision for these analytes, as indicated by relative standard deviations, were less than 8% for both intra‐ and inter‐day analysis. Accuracy, expressed as the mean extraction recovery, was between 74 to 88%. A standard addition method was used to quantitate 4‐tert‐octylphenol and 4‐nonylphenol isomers, and the concentrations ranged from 120 to 930 ng/L in various environmental water samples.  相似文献   

13.
A novel microextraction method based on vortex‐ and CO2‐assisted liquid–liquid microextraction with salt addition for the isolation of furanic compounds (5‐hydroxymethyl‐2‐furaldehyde, 5‐methyl‐2‐furaldehyde, 2‐furaldehyde, 3‐furaldehyde, 2‐furoic and 3‐furoic acids) was developed. Purging the sample with CO2 was applied after vortexing to enhance the phase separation and mass transfer of the analytes. The optimum extraction conditions were: extraction solvent (volume), propyl acetate (125 μL); sample pH, 2.4; vortexing time, 45 s; salt concentration, 25% w/v and purging time, 5 min. The analytes were separated using an ODS Hypersil C18 column (250×4.6 mm i.d, 5 μm) under gradient flow. The proposed method showed good linearities (r2 >0.999), low detection limits (0.08–1.9 μg/L) and good recoveries (80.7–122%). The validated method was successfully applied for the determination of the furanic compounds in concentrated juice (mango, date, orange, pomegranate, roselle, mangosteen and soursop) and dried fruit (prune, date and apricot paste) samples.  相似文献   

14.
A homogeneous liquid–liquid microextraction alternative, based on the use of switchable hydrophilicity solvents, is presented. The extraction technique makes use of 125 μL of a water‐immiscible solvent (N,N‐dimethylcyclohexylamine) that can be solubilized in the aqueous phase in 1:1 ratio using CO2 as a reagent. After the extraction, phase separation is induced by the addition of sodium hydroxide that produces a change on the ionization state of the amine, and centrifugation was not necessary. The extraction technique has been optimized and characterized using the determination of triazine herbicides by gas chromatography with mass spectrometry in water samples. The presence of metallic ions in environmental waters as interferents is easily avoided by the addition of ethylenediaminetetraacetic acid before the microextraction procedure. The proposed method allows the determination of the target analytes at the low microgram per liter range with good precision (relative standard deviation lower than 12.5%).  相似文献   

15.
This work presents a method to separate polar naphthalenesulfonate (NS) isomers by capillary zone electrophoresis (CZE) with ultraviolet detection in industrial effluents and river water samples. The method involves extraction of samples by a polystyrene‐divinylbenzene copolymer (PS‐DVB) solid‐phase extraction (SPE) cartridge. The most effective CZE separation conditions were obtained in 20 mM borate buffer with 30% acetonitrile at pH 9.0 and 30 °C. The method proposed herein provides a high precision and sensitivity for NS isomers, to quantitation at ≤ 1.0 μg/L in 200 mL of the water samples. Recovery of the NS isomers in spiked water samples ranged from 73% to 87% while RSD ranging from 5.6 to 9.7%. The analysis of industrial effluents and river water samples was performed and naphthalene‐2‐sulfonate was found as a major pollutant. The difficulties in quantitating and identifying analytes in complex environmental samples can be resolved by using an internal standard response factor to calculate concentrations and relative migration times for peak confirmation.  相似文献   

16.
Ultrasound-assisted emulsification microextraction and dispersive liquid-liquid microextraction were compared for extraction of ephedrine, norephedrine, and pseudoephedrine from human urine samples prior to their determination by capillary electrophoresis. Formation of a microemulsion of the organic extract with an aqueous solution (at pH 3.2) containing 10% methanol facilitated the direct injection of the final extract into the capillary. Influential parameters affecting extraction efficiency were systematically studied and optimized. In order to enhance the sensitivity further, field-amplified sample injection was applied. Under optimum extraction and stacking conditions, enrichment factors of up to 140 and 1750 as compared to conventional capillary zone electrophoresis were obtained resulting in limits of detection of 12-33 μg/L and 1.0-2.8 μg/L with dispersive liquid-liquid microextraction and ultrasound-assisted emulsification microextraction when combined with field-amplified sample injection. Calibration graphs showed good linearity for urine samples by both methods with coefficients of determination higher than 0.9973 and percent relative standard deviations of the analyses in the range of 3.4-8.2% for (n = 5). The results showed that the use of ultrasound to assist microextraction provided higher extraction efficiencies than disperser solvents, regarding the hydrophilic nature of the investigated analytes.  相似文献   

17.
Solid‐phase extraction (SPE) in tandem with dispersive liquid–liquid microextraction (DLLME) has been developed for the determination of mononitrotoluenes (MNTs) in several aquatic samples using gas chromatography‐flame ionization (GC‐FID) detection system. In the hyphenated SPE‐DLLME, initially MNTs were extracted from a large volume of aqueous samples (100 mL) into a 500‐mg octadecyl silane (C18) sorbent. After the elution of analytes from the sorbent with acetonitrile, the obtained solution was put under the DLLME procedure, so that the extra preconcentration factors could be achieved. The parameters influencing the extraction efficiency such as breakthrough volume, type and volume of the elution solvent (disperser solvent) and extracting solvent, as well as the salt addition, were studied and optimized. The calibration curves were linear in the range of 0.5–500 μg/L and the limit of detection for all analytes was found to be 0.2 μg/L. The relative standard deviations (for 0.75 μg/L of MNTs) without internal standard varied from 2.0 to 6.4% (n=5). The relative recoveries of the well, river and sea water samples, spiked at the concentration level of 0.75 μg/L of the analytes, were in the range of 85–118%.  相似文献   

18.
This study describes a method for the simultaneous determination of 12 synthetic cannabinoids by MEKC–MS/MS using a volatile surfactant (ammonium perfluorooctanoate) as a constituent of the micellar pseudostationary phase. Although most synthetic cannabinoids comigrated by a CZE method, sufficient separation could be achieved by the proposed method. The best separation was made possible by 50 mM ammonium perfluorooctanoate in 20% v/v acetonitrile/water (apparent pH* 9.0) as the BGE, followed by MS detection using a sheath liquid composed of 5 mM ammonium formate in 50% v/v methanol/water mixed hydro‐organic solvent. The standard calibration curve for all analytes showed good linearity (r > 0.99). Satisfactory recoveries, ranging from 89.5 to 101.7%, were obtained. The LODs were 6.5–76.5 μg/g for the target analytes. This method appears to be a useful tool for the identification of synthetic cannabinoids in illegal herbal incense blends.  相似文献   

19.
A new method for the separation of a mixture of different herbicides (propham, chlorpropham, asulam, metamitron, linuron, and maleic hydrazide) using MEKC is proposed. A base‐line separation for the mixture of herbicides is achieved in less than six minutes. The detection limits obtained for all the herbicides were lower than 1.0 μM using UV detection. This separation method was used for the determination of maleic hydrazide in potato samples. If a dual (UV‐electrochemical) detection system is employed, chlorpropham can be also detected. The results obtained showed that electrochemical detection was ten folds more sensitive than UV detection for maleic hydrazide. The detection limit of the proposed method for maleic hydrazide employing electrochemical detection was 1.3 μg g?1, this value is lower than 50 μg g?1, which is the maximum residue level permitted for this plant growth regulator in potato samples. The results obtained in the work clearly demonstrate the advantage of using electrochemical detection coupled to capillary electrophoresis, using this detection the concentration limits are not compromised by miniaturization and the components required are simple and inexpensive.  相似文献   

20.
The development of a simple and sensitive analytical approach that combines multiple monolithic fiber solid‐phase microextraction with liquid desorption followed by high‐performance liquid chromatography with diode array detection is proposed for the determination of trace levels of seven steroid sex hormones (estriol, 17β‐estradiol, testosterone, ethinylestradiol, estrone, progesterone and mestranol) in water and urine matrices. To extract the target analytes effectively, multiple monolithic fiber solid‐phase microextraction based on a polymeric ionic liquid was used to concentrate hormones. Several key extraction parameters including desorption solvent, extraction and desorption time, pH value and ionic strength in sample matrix were investigated in detail. Under the optimal experimental conditions, the limits of detection were found to be in the range of 0.027–0.12 μg/L. The linear range was 0.10–200 μg/L for 17β‐estradiol, 0.25–200 μg/L estriol, ethinylestradiol and estrone, and 0.50–200 μg/L for the other hormones. Satisfactory linearities were achieved for analytes with the correlation coefficients above 0.99. Acceptable method reproducibility was achieved by evaluating the repeatability and intermediate precision with relative standard deviations of both less than 8%. The enrichment factors ranged from 54‐ to 74‐fold. Finally, the proposed method was successfully applied to the analysis of steroid sex hormones in environmental water samples and human urines with spiking recoveries ranged from 75.6 to 116%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号