首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 468 毫秒
1.
《Electroanalysis》2006,18(1):70-76
A lead‐copper film electrode was proposed for Co(II) determination by catalytic adsorptive stripping voltammetry. The electrode was plated in situ and hence the exchange of a solution after plating step was not required. At optimized conditions the calibration graph for Co(II) was linear from 5×10?10 to 2×10?8 mol L?1 for accumulation time of 15 s. The relative standard deviation for Co(II) determination at concentration 5×10?9 mol L?1 was 4.1%. The detection limits for Co(II) were 1.2×10?10 and 1.0×10?11 mol L?1 for an accumulation time of 15 and 180 s, respectively. The method was applied to Co(II) determination in certified reference material and other water samples.  相似文献   

2.
An adsorptive stripping voltammetric procedure for the determination of folic acid at an in situ plated lead film electrode was described. Formation of lead film on a glassy carbon substrate and accumulation of folic acid was performed simultaneously from an acetate buffer solution of pH 5.6 at the potential ?0.88 V. The measurements were carried out from aerated solutions. The calibration graph for an accumulation time of 300 s was linear from 2×10?9 to 5×10?8 mol L?1. The detection limit was 7×10?10 mol L?1, the relative standard deviation for 2×10?8 mol L?1 of folic acid was 3.9%. The proposed procedure was applied to folic acid determinations in pharmaceutical preparations.  相似文献   

3.
For the first time an in situ plated bismuth film electrode has been applied to catalytic adsorptive stripping voltammetry of cobalt in the presence of nitrite. At optimised conditions bismuth film was plated before each measurement for 30 s at ?1.0 V from a sample solution with the added supporting electrolyte and Bi(III) in the form of its complex with tartrate. The calibration graph for Co(II) for an accumulation time of 120 s was linear from 5×10?10 to 1×10?8 mol L?1. The detection limit was 1.1×10?10 mol L?1. The proposed procedure was applied for Co(II) determination in certified water reference material.  相似文献   

4.
A new method using differential pulse adsorptive stripping voltammetry for the determination of atrazine (ATZ) in natural water samples using a bismuth film electrode (BiFE) is proposed. The calibration curve was linear in the atrazine concentration range from 6.7×10?7 to 2.0×10?5 mol L?1, with a limit of detection (LOD) of 1.4×10?7 mol L?1. The proposed electrode was applied for atrazine determination with satisfactory results compared with a high‐performance liquid chromatography method (HPLC).  相似文献   

5.
This article the first reports on a fabrication and application of an electrochemical three electrode micro‐set containing: in situ plated lead film on carbon fiber working microelectrode, Ag/AgCl reference electrode and a platinum wire counter electrode placed in one casing for simultaneous Ni(II) and Co(II) traces determination by square wave adsorptive stripping voltammetry (SW AdSV). Ni(II) and Co(II) in forms of their complexes with nioxime were accumulated on the lead film plated on a carbon fibers microelectrode during standard procedure of measurement. Thanks to the fact that measurements were performed in micro‐vessel of a volume of 200 μl small amounts of reagents were used to prepare samples for measurements. In addition, because of the use of microelectrode, sample solutions were not mixed during accumulation step of measurements. This fact creates the possibility of conducting fields analysis. The experimental parameters (composition of the supporting electrolyte, potential and time of accumulation) and possible interference effects were investigated. The linear calibration graphs for Ni(II) and Co(II) were in the range from 2×10?9 to 1×10?7 mol L?1 and from 2×10?10 to 1×10?8 mol L?1 for Ni(II) and Co(II), respectively. The correctness of the proposed method was checked by determining Ni(II) and Co(II) in the certified reference material (SPS‐SW1) with satisfactory results.  相似文献   

6.
A bare glassy carbon electrode is applied to nickel determination by adsorptive stripping voltammetry in the presence of dimethylglyoxime as a complexing agent. A procedure of nickel determination and electrode regeneration was proposed. The calibration graph for Ni(II) for an accumulation time of 120?s was linear from 2?×?10?9 to 1?×?10?7?mol?L?1. The detection limit was 8.2?×?10?10?mol?L?1. The relative standard deviation for a solution containing 2?×?10?8?mol?L?1 of Ni(II) was 4.1%. The proposed procedure was applied for Ni(II) determination in certified water reference materials.  相似文献   

7.
An adsorptive stripping voltammetric procedure for the determination of cobalt in a complex matrices at an in situ plated lead film electrode was described. The procedure exploits the enhancement effect of a cobalt peak observed in the system Co(II)–nioxime–piperazine‐1,4‐bis(2‐ethanesulfonic acid)–cetyltrimethylammonium bromide. The calibration graph was linear from 5×10?10 to 2×10?8 mol L?1 and from 1×10?10 to 1×10?9 mol L?1 for the accumulation times 120 and 600 s, respectively. The detection limit (based on the 3 σ criterion) for Co(II) following accumulation time of 600 s was 1.1×10?11 mol L?1. The interference of high concentrations of foreign ions and surfactants was studied.  相似文献   

8.
A fast adsorptive stripping voltammetric procedure for simultaneous determination of Ni(II) and Co(II) in the presence of nioxime as a complexing agent at an in situ plated lead film electrode was described. The time of determination of these ions was shortened due to the application of gold as a substrate for lead film. At gold substrate lead film formation and accumulation of Ni(II) and Co(II) complexes with nioxime proceeds simultaneously. To obtain a stable signals for both ions a simple procedure of activation of the electrode was proposed. Calibration graphs for an accumulation time of 20 s were linear from 5×10?9 to 1×10?7 mol L?1 and from 5×10?10 to 1×10?8 mol L?1 for Ni(II) and Co(II), respectively. The procedure with the application of a lead film electrode on a gold substrate was validated in the course of Ni(II) and Co(II) determination in certified reference materials.  相似文献   

9.
Adsorptive stripping voltammetry is a very sensitive and selective method for determination of drugs and organic substances in biological fluids. We have shown that determination of testosterone by adsorptive stripping voltammetry is possible using a lead film electrode. The lead film plating process and accumulation of testosterone were performed simultaneously from an acetate buffer solution of pH = 5.2 at a potential of −1.1 V. The measurements were carried out in undeaerated solutions. The detection limit was 9 × 10−9 mol L−1 for an accumulation time of 120 s; the relative standard deviation for 1 × 10−7 mol L−1 testosterone was 3.8%. The proposed voltammetric procedure for determination of testosterone could be applied to its determination in a pharmaceutical preparation and human urine samples directly without any separation steps.  相似文献   

10.
WANG Yuane  PAN Dawei  LI Xinmin  QIN Wei 《中国化学》2009,27(12):2385-2391
A bismuth/multi‐walled carbon nanotube (Bi/MWNT) composite modified electrode for determination of cobalt by differential pulse adsorptive cathodic stripping voltammetry is described. The electrode is fabricated by potentiostatic pre‐plating bismuth film on an MWNT modified glassy carbon (GC) electrode. The Bi/MWNT composite modified electrode exhibits enhanced sensitivity for cobalt detection as compared with the bare GC, MWNT modified and bismuth film electrodes. Numerous key experimental parameters have been examined for optimum analytical performance of the proposed electrode. With an adsorptive accumulation of the Co(II)‐dimethylglyoxime complex at ?0.8 V for 200 s, the reduction peak current is proportional to the concentration of cobalt in the range of 4.0×10?10?1.0×10?7 mol/L with a lower detection limit of 8.1×10?11 mol/L. The proposed method has been applied successfully to cobalt determination in seawater and lake water samples.  相似文献   

11.
《Electroanalysis》2002,14(23):1654-1660
It was found that melatonin could be incorporated and accumulated on the surface of the glassy carbon electrode which was activated electrochemically by pretreatment in sodium hydroxide solution by means of cycling the potential well into the positive limit of the solvent. In Britton‐Robinson buffer solution (pH 6.7), melatonin gave a sensitive oxidation wave at a potential of +0.65 V (vs.Ag/AgCl) by using Osteryoung square‐wave stripping voltammetry (OSWSV). The oxidation process has been shown to be irreversible and adsorption‐controlled at this electrode by means of cyclic voltammetry and linear sweep voltammetry. A chronocoulometric characterization of the adsorption characteristics of melatonin at this electrode is also presented. The factors affecting the peak current were optimized, and the dependence of peak currents on the concentration of melatonin was found to be linear in the range 8.0×10?7?1.0×10?5 mol L?1. A detection limit of 5.0×10?8 mol L?1 was obtained (signal‐to‐noise ratio of 3). This method was applied to the assay of melatonin in tablets and capsules with good recoveries (98–100%).  相似文献   

12.
《Analytical letters》2012,45(6):1143-1158
Abstract

A sensitive and reliable stripping voltammetry method was developed to determine the presence of Ceftiofur antibiotic drug. This method is based on the adsorptive accumulation of the drug at a hanging mercury drop electrode and then the initiation of a negative sweep that yielded well‐defined cathodic peaks at ?0.65 V (1 C) and ?1.00 V (2 C) vs. Ag/AgCl reference electrode. To achieve high sensitivity, various experimental and instrumental variables were investigated such as supporting electrolyte, pH, accumulation time and potential, drug concentration, scan rate, convection rate, and working electrode area. The monitored adsorptive current of peak 1 C was directly proportional to the concentration of Ceftiofur; it shows a linear response in the range from 0.50×10?8 to 8.00×10?8 mol L?1 (correlation coefficient=0.998); and the limit of detection is 6.00×10?10 mol L?1 at an accumulation time of 300 s. The applicability of this approach was illustrated by the determination of Ceftiofur in pharmaceutical preparations and bovine serum.  相似文献   

13.
The behaviour of oxazepam in adsorptive stripping voltammetry was studied taking into account those conditions which have an influence on the accumulation step (electrolyte, pH, time, potential, drop size and stirring rate), rest time and stripping step (pulse amplitude and scan rate). Oxazepam can be determined at a hanging mercury drop electrode by differential-pulse voltammetry in 0.008 M Britton-Robinson buffer at pH 2.0 with a ?0.50 V accumulation potential. Its detection limit was found to be 3.6 × 10?10 M (30-s accumulation) and the relative standard deviation for oxazepam concentrations in the range 2.8 × 10?8?4.0 × 10?7 M is lower than 2.8% (80-s accumulation). In addition, a procedure using adsorptive stripping voltammetry was developed to study the interactions occurring between human albumin and the camazepam metabolic series (camazepam, temazepam and oxazepam). The interactions decreased in the order temazepam ? oxazepam ? camazepam and the groups and structural modifications favouring interaction were determined.  相似文献   

14.
A lead film plated in situ at a carbon paste support was tested as a novel, potential electrode for adsorptive stripping voltammetric determination of cobalt traces in an ammonia buffer solution. To show the practical applicability of the new electrode, a catalytic adsorptive Co system in a supporting electrolyte containing 0.1 M ammonia buffer, 5×10?4 M nioxime and 0.25 M nitrite was selected and investigated as a model solution. Pb and Co ions were simultaneously accumulated in situ on the electrode surface: Pb ions electrochemically at ?1.3 V) and then at ?0.75 V, at which potential the Co(II)‐nioximate complex was also pre‐concentrated via adsorption. Instrumental parameters, such as the time of nucleation and formation of Pb film deposits, the time of accumulation of the Co‐nioxime complex at the PbF/CPE, and the procedures of electrode regeneration, were optimized to obtain good reproducibility and sensitivity of the Co response. The optimized procedure yields favorable and highly stable stripping responses with good precision (RSD=3% for a 5×10?8 M Co) and good linearity (up to 5×10?7 M, coefficient of determination, R=0.996). The detection limit was 4×10?10 M Co (0.023 μg L?1) for an accumulation time of 120 s. The method enables the determination of Co in the presence of high excesses of Ni or Zn. The voltammetric data were correlated with the structural characterization by scanning electron microscopy (SEM) and X‐ray fluorescence spectroscopy (XRF).  相似文献   

15.
The paper describes the first electrochemical method (differential pulse adsorptive stripping voltammetry, DPAdSV) using a screen‐printed sensor with a carbon/carbon nanofibers working electrode (SPCE/CNFs) for the direct determination of low (real) concentrations of paracetamol (PA) in environmental water samples. By applying this sensor together with DPAdSV, two linear PA concentration ranges from 2.0×10?9 to 5.0×10?8 mol L?1 (r=0.9991) and 1.0×10?7–2.0×10?6 mol L?1 ( r=0.9994) were obtained. For the accumulation time of 90 s, the limit of detection was 5.4×10?10 mol L?1. Moreover, the SPCE/CNFs sensor and the DPADSV procedure for PA determination are potentially applicable in field analysis. The process of PA adsorption at the SPCE/CNFs surface was investigated by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and theoretical studies. In the theoretical study of the interaction of CNF and PA, the first species was modelled by graphene‐like clusters containing up to 37 rings. It was found that the preferable orientation of PA is parallel to the carbon surface with the binding energy of about ?68 kJ/mol calculated by symmetry‐adapted perturbation theory (SAPT). Both the selectivity and the accuracy of the developed sensor for real sample analysis were also investigated using Polish river and sea samples.  相似文献   

16.
The use of a thin thiol‐functionalized silica film modified glassy carbon electrode in the determination of Hg(II) ions in a natural water sample is described. A typical measurement involves two successive steps: a glassy carbon electrode coated with a thin mesoporous silica film containing 10% of mercaptopropyl groups, according to the MPTMS/TEOS ratio in the starting sol‐gel, was first immersed into the accumulation medium for 15 min, then removed, and finally transferred into a detection solution containing KCl 1.0 mol L?1 where detection was performed by anodic stripping voltammetry. In this medium the previously accumulated Hg2+ species complexed by the thiol groups in an open circuit preconcentration step is then directly reduced at ?0.6 V during 60 s prior to be quantified by a differential pulse anodic scan from ?0.6 to 0.3 V (vs. Ag/AgCl). A stripping peak appeared at about ?0.01 V, which is directly proportional to the quantity of the analyte previously accumulated into the film. The best results were obtained under the following conditions: 100 mV pulse amplitude and 10 mV s?1 scan rate in 1.0 mol L?1 KCl solution pH 2.0. Using such parameters a linear dynamic range from 1.00 to 10.0×10?8 mol L?1 Hg(II) was observed with a limit of detection of 4.3 nmol L?1 for an accumulation time of 15 min. Hg(II) spiked in a natural water sample was determined between 97.0 and 101.4% mean recovery at 10?8 mol L?1 level. The results indicate that this electrode is sensitive and selective for the Hg(II)determination.  相似文献   

17.
The in situ plated lead film electrode was proposed for the first time for adsorptive stripping voltammetric determination of gallium in water samples. The method was based on simultaneous lead film formation and Ga(III)‐cupferron complex preconcentration at ?0.7 V and its cathodic stripping during the potential scan. The composition of the supporting electrolyte, cupferron concentration, conditions of lead film formation, potential and time of accumulation were studied in detail. Under optimum conditions the limit of detection was 3.8×10?9 mol L?1. The proposed procedure was validated in the course of Ga(III) determination in waste water certified reference materials.  相似文献   

18.
A new way of decreasing the detection limit ‐ double deposition and stripping steps was proposed to determine trace amounts of gold(III) by anodic stripping voltammetry. Two carbon composite electrodes that differed drastically in their surface areas were used for the measurements. The calibration graph was linear from 1×10?9 to 1×10?8 mol L?1 following deposition time of 300 s at the first and the second electrode. The detection limit was found to be 2.3×10?10 and 1.4×10?11 mol L?1 for deposition time 600 and 2400 s, respectively. It is the lowest detection limit obtained so far for gold(III) determination in stripping voltammetry.  相似文献   

19.
In this article a solid lead electrode (PbE) was utilized for the first time for determination of organic substances by means of adsorptive stripping voltammetry. A new procedure of simultaneous determination of rutin and folic acid was developed. Two well shaped and well separated reduction signals of rutin and folic acid were obtained with the use of PbE. The optimization of analytical procedure was presented. The calibration graphs for rutin and folic acid for an accumulation time of 120 s were linear in the ranges from 2×10?9 to 1×10?7 mol L?1 and from 2×10?9 to 5×10?8 mol L?1, respectively. The obtained detection limits for rutin and folic acid determination following accumulation time of 120 s were 7.9×10?10 and 8.4×10?10 mol L?1. Potential interference effects were investigated. The proposed procedure was used for analysis of pharmaceutical preparations with satisfactory results showing practical applications. The analytical parameters of the proposed procedure were compared with other voltammetric procedures of mentioned substances determination.  相似文献   

20.
The paper presents the first report on application of a “hybrid” lead film electrode for the adsorptive stripping voltammetric determination of Ni(II) in the presence of nioxime as a complexing agent. The strategy to create a “hybrid” electrode is based on the combination of ex situ and in situ plating methods and the use of a reversibly deposited mediator metal (Zn) for the lead film formation. The surface morphology of a new sensor was characterized by atomic force microscopy. The detection limit for Ni(II) obtained at 120 s of accumulation time was 3.9×10?11 mol L?1. The proposed method was validated for the determination of nickel in water certified reference materials with good results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号