首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Drug-eluting stents have attracted significant attention in the medical community and pharmaceutical industry due to their proven success in significantly reducing restenosis. Abbott Laboratories is developing a drug-eluting stent coated with zotarolimus and swine was recently used as an animal model for the pre-clinical study of stent implantation. In this article, we present a detailed experimental design and results for the validation and sample analysis of zotarolimus drug concentration in stented swine artery samples. Introduction of tissue quality control (QC) samples allows evaluation of the entire analytical process as well as the stability of the drug in both original tissue and homogenized tissue samples. In addition, a novel approach using 100% swine blood as the homogenization solution was developed for the consistency of the liquid-liquid extraction recovery and stability of the zotarolimus in tissue homogenates. Standards were prepared by spiking zotarolimus working solution in swine blood and tissue QC samples were used along with the artery samples during the sample analysis. The linear dynamic range of blood standard samples is from 0.61 to 333.20 ng/mL to accommodate the predicted artery homogenate concentrations. Overall tissue QC %CV during the method validation was from 4.4% to 8.6%. The overall %bias of tissue QC samples during the method validation was from -7.3% to 16.6%. The method was successfully applied for the analysis of swine artery samples. A similar approach for method validation and sample analysis has been successfully applied for the analysis of swine myocardium, kidney and liver tissue samples.  相似文献   

2.
Sirolimus, an effective immunosuppressive agent, is used for drug eluting stents. During stent development, an analytical method for the determination of sirolimus in tissue needs to be established. Normally, tissue samples are homogenized and then analyzed against the calibration standards prepared in a tissue homogenate. This approach provides insufficient control of the homogenization process. In this paper, tissue quality control samples were introduced for the optimization of the homogenization process during method development, but also allowance for the performance evaluation of the entire analytical process. In addition, a new approach using rabbit blood as a homogenization medium was developed to stabilize sirolimus in rabbit tissue homogenates. Calibration standards and quality controls were prepared by spiking different sirolimus working solutions into rabbit blood. Homogenization quality control samples were prepared by injecting other sirolimus working solutions into empty test tubes and pre-cut arteries within pre-defined masses. A high-throughput homogenization procedure was optimized based on the specific chemical properties of sirolimus. The linear dynamic range was between 49.9 pg/mL and 31.9 ng/mL to accommodate the expected artery homogenate concentrations. Additionally, quality controls in rabbit blood were also used in the extraction to support the calibration standards. The accuracy and precision of the quality controls in rabbit blood reflect the extraction performance and the accuracy and precision of the homogenization tissue quality controls reflect the overall performance of the method. The mean bias was between -4.5 and 0.2% for all levels of quality controls in the blood and between 4.8 and 14.9% for all levels of the homogenization tissue quality controls. The CVs of all concentration levels were < or =5.3% for the quality controls in blood and < or =9.2% for the homogenization tissue quality controls. The method was successfully applied to determine the concentration of sirolimus in the rabbit arteries.  相似文献   

3.
Validated liquid chromatography/tandem mass spectrometric (LC/MS/MS) methods are now widely used for quantitation of drugs in post-dose (incurred) biological samples for the assessment of pharmacokinetic parameters, bioavailability and bioequivalence. In accordance with the practice currently accepted within the pharmaceutical industry and the regulatory bodies, validation of a bioanalytical LC/MS/MS method is performed using standards and quality control (QC) samples prepared by spiking the drug (the analyte) into the appropriate blank biological matrix (e.g. human plasma). The method is then declared to be adequately validated for analyzing incurred biological samples. However, unlike QC samples, incurred samples may contain an epimer or another type of isomer of the drug, such as a Z or E isomer. Such a metabolite will obviously interfere with the selected reaction monitoring (SRM) transition used for the quantitation of the drug. The incurred sample may also contain a non-isomeric metabolite having a molecular mass different from that of the drug (such an acylglucuronide metabolite) that can still contribute to (and hence interfere with) the SRM transition used for the quantitation of the drug. The potential for the SRM interference increases with the use of LC/MS/MS bioanalytical methods with very short run times (e.g. 0.5 min). In addition, a metabolite can potentially undergo degradation or conversion to revert back to the drug during the multiple steps of sample preparation that precede the introduction of the processed sample into the LC/MS/MS system. In this paper, we recommend a set of procedures to undertake with incurred samples, as soon as such samples are available, in order to establish the validity of an LC/MS/MS method for analyzing real-life samples. First, it is recommended that the stability of incurred samples be investigated 'as is' and after sample preparation. Second, it is recommended that potential SRM interference be investigated by analyzing the incurred samples using the same LC/MS/MS method but with the additional incorporation of the SRM transitions attributable to putative metabolites (multi-SRM method). The metabolites monitored will depend on the expected metabolic products of the drug, which are predictable based on the functional groups present in the chemical structure of the drug. Third, it is recommended that potential SRM interference be further investigated by analyzing the incurred samples using the multi-SRM LC/MS/MS method following the modification of chromatographic conditions to enhance chromatographic separation of the drug from any putative metabolites. We will demonstrate the application of the proposed strategy by using a carboxylic acid containing drug candidate and its acylglucuronide as a putative metabolite. Plasma samples from the first-in-man (FIM) study of the drug candidate were used as the incurred samples.  相似文献   

4.
Levosimendan (Simdax) is an approved drug in approximately 40 countries and currently in phase III clinical studies in the USA and Europe. An accurate, high-throughput and rugged assay is critical to support these clinical trials. Due to the mechanism of drug metabolism, the drug and its active metabolites often have significant differences in their chemical properties. In order to achieve high assay throughput and low sample volumes, a single bioanalytical assay for the drug and its metabolites is preferred. However, this need may prevent the optimization of both high-performance liquid chromatography (HPLC) and mass spectrometric ionization conditions. The chemical properties of levosimendan are significantly different from those of its two active metabolites, OR-1855 and OR-1896. Here, we present a novel strategy for high-throughput analysis of levosimendan and its metabolites. A 96-well liquid/liquid extraction procedure was developed for sample preparation. A single liquid chromatography/tandem mass spectrometry (LC/MS/MS) system with two separate mobile phases, shared backwash solvent and conditioning solvent, was developed to perform sequential LC separation for levosimendan and the metabolites. Levosimendan was eluted by 5 mM ammonium acetate in 33.3% acetonitrile and detected using negative ionization mode MS/MS monitoring. The metabolites were eluted by 5 mM ammonium acetate and 0.2% acetic acid in 20% acetonitrile and detected with positive ionization mode MS/MS monitoring. The method has been demonstrated to have excellent precision and accuracy, with high assay ruggedness during method validation and clinical sample analysis. The linear dynamic ranges were approximately 200-50,000 pg/mL for levosimendan and approximately 500-130,000 pg/mL for both metabolites. The coefficient of determination (r2) for all analytes was greater than 0.9985. The intra-assay %CVs for QC samples were from 0.9% to 2.0% for levosimendan, 0.9% to 3.2% for OR-1855, and 0.4% to 4.9% for OR-1896. The inter-assay %CVs for QC samples were from 1.2% to 1.8% for levosimendan, 1.3% to 2.7% for OR-1855, and 1.4% to 3.4% for OR-1896. The mean % biases for QC samples were from 1.5% to 5.5% for levosimendan, -1.4% to 2.6% for OR-1855, and -0.3% to 4.5% for OR-1896. By using a single extraction approach coupled with sequential LC/MS/MS analysis for levosimendan and its metabolites, the assay maintained high throughput and low sample volume usage.  相似文献   

5.
A liquid chromatographic/tandem mass spectrometric (LC/MS/MS) assay for the quantitative analysis of the novel anticancer drug ABT-518 and the screening of six potential metabolites in human plasma has been developed and validated to support a phase I study with the drug. ABT-518 is an inhibitor of matrix metalloproteinases, which are associated with tumor growth and development of metastasis. Plasma samples were prepared for analysis using a simple solid-phase extraction method on phenyl cartridges. LC separation was performed on a Zorbax extend C18 column (150 x 2.1 mm i.d., 5 microm particle size) using a mobile phase of methanol-aqueous 10 mM ammonium hydroxide (80:20, v/v) pumped at a flow-rate of 0.2 ml min(-1). An API2000 triple-quadrupole mass spectrometer was used for specific and sensitive detection. The best chromatographic speed (total run time 8 min) and peak shapes were obtained by employing an alkaline mobile phase (pH in aqueous phase approximately 10). Furthermore, an alkaline eluent was favored in order to obtain a better overall sensitivity for the protonated analytes. The dynamic range was from 10 to 1000 ng ml(-1) from 500 microl of plasma for ABT-518 and the metabolites were detected at levels of the same order of magnitude. Inter-assay accuracies for ABT-518 at five concentration levels were between -9.24 and 6.93% and inter-assay precisions were always <10.7%. Analyte stability was not critical during either storage or processing. This method was successfully applied in a phase I clinical study of ABT-518. The active drug, ABT-518, and all of the metabolites included in the assay could be identified in plasma from dosed patients. We believe that the method described in this paper using an alkaline mobile phase in combination with a basic stable analytical column may also be generally useful for the bioanalysis of other basic drugs.  相似文献   

6.
A new quantitation method for mass spectrometry imaging (MSI) with matrix-assisted laser desorption/ionization (MALDI) has been developed. In this method, drug concentrations were determined by tissue homogenization of five 10 μm tissue sections adjacent to those analyzed by MSI. Drug levels in tissue extracts were measured by liquid chromatography coupled to tandem mass spectrometry (LC/MS/MS). The integrated MSI response was correlated to the LC/MS/MS drug concentrations to determine the amount of drug detected per MSI ion count. The study reported here evaluates olanzapine in liver tissue. Tissue samples containing a range of concentrations were created from liver harvested from rats administered a single dose of olanzapine at 0, 1, 4, 8, 16, 30, or 100 mg/kg. The liver samples were then analyzed by MALDI-MSI and LC/MS/MS. The MALDI-MSI and LC/MS/MS correlation was determined for tissue concentrations of ~300 to 60,000 ng/g and yielded a linear relationship over two orders of magnitude (R(2) = 0.9792). From this correlation, a conversion factor of 6.3 ± 0.23 fg/ion count was used to quantitate MSI responses at the pixel level (100 μm). The details of the method, its importance in pharmaceutical analysis, and the considerations necessary when implementing it are presented.  相似文献   

7.
ABT-869 is a novel ATP-competitive inhibitor for all the vascular endothelial growth factor (VEGF) and platelet-derived growth factor (PDGF) receptor tyrosine kinases (RTKs). It is one of the oncology drugs in development at Abbott Laboratories and has great potential for enhanced anti-tumor efficacy as well as activity in a broad range of human cancers. We report here an accurate, precise and rugged liquid chromatography/mass spectrometry (LC/MS/MS) assay for the quantitative measurement of ABT-869 and its acid metabolite A-849529. A fully automated 96-well liquid/liquid extraction method was achieved utilizing a Hamilton liquid handler. The only manual intervention required prior to LC/MS/MS injection is to transfer the 96-well plate to a drying rack to dry the extracts then transfer the plate back to the Hamilton for robotic reconstitution. The linear dynamic ranges were from 1.1 to 598.8 ng/mL for ABT-869 and from 1.1 to 605.8 ng/mL for A-849529. The coefficient of determination (r2) for all analytes was greater than 0.9995. For the drug ABT-869, the intra-assay coefficient of variance (CV) was between 0.4% and 3.7% and the inter-assay CV was between 0.9% and 2.8%. The inter-assay mean accuracy, expressed as percent of theoretical, was between 96.8% and 102.2%. For the metabolite A-849529, the intra-assay CV was between 0.5% and 5.1% and the inter-assay CV was between 0.8% and 4.9%. The inter-assay mean accuracy, expressed as percent of theoretical, was between 96.9% and 100.6%.  相似文献   

8.
An LC–MS/MS method was developed and validated for bioanalysis of clofazimine in human dried blood spot (DBS) samples in support of a clinical study on multidrug‐resistant tuberculosis in developing countries. The validated assay dynamic range was from 10.0 to 2000 ng/mL using a 1/8 inch DBS punch. The accuracy and precision of the assay were ±11.0% (bias) and ≤13.5% (CV) for the LLOQs (10.0 ng/mL) and ±15% (bias) and ≤15% (CV) for all other QC levels. The assay was proved to be free from the possible impact owing to spot size and storage temperature (e.g. at 60°C, ≤ − 60°C). The validated assay is well suited for the intended clinical study where conventional pharmacokinetic sample collection is not feasible.  相似文献   

9.
A novel liquid chromatography/tandem mass spectrometry (LC/MS/MS)-based depletion method for measuring compound partitioning between human plasma and red blood cells (RBC) in a drug discovery environment is presented. Conventionally, RBC partitioning is determined by separate measurements of drug concentrations in equilibrating plasma and whole blood or RBC using separate standards prepared in their respective matrices, i.e., in plasma and whole blood or RBC lysates. The process is very tedious, labor-intensive, and difficult to automate. In addition, interferences from the heme and other highly abundant cellular composites make the measurement of the drug concentration in whole blood or RBC inevitably variable even with a highly specific LC/MS/MS method. Therefore, there is an imminent need to develop a straightforward and fast method to assess the partitioning of drug-like compounds in RBC.This work describes an LC/MS/MS-based depletion assay that measures the compound concentration in plasma that has been equilibrating with RBC. Compounds were spiked into fresh human whole blood and plasma respectively to a final concentration of 500 nM. Both the spiked whole blood and plasma control were incubated at 37 degrees C for up to 60 min. During the time course, aliquots of plasma and whole blood from both incubation mixtures were sampled at 10 and 60 min. The whole blood samples were centrifuged to yield the plasma. The plasma samples from both incubations were extracted using a protein precipitation method, and analyzed using LC/MS/MS under the multiple-reaction monitoring (MRM) mode. The RBC partitioning ratio was calculated using the analyte peak area responses of the plasma samples through an equation deduced in this work.The method was first tested using two commercial compounds, phenoprobamate and acetazolamide, to determine the optimal incubation conditions and the concentration dependency of the assay. The assay reproducibility was also assessed by three inter-day assays for phenoprobamate. This method was further evaluated using 20 commercial compounds of different classes with a wide range of RBC partitioning coefficients and the results were compared with those reported in the literature. Excellent correlation (R2=0.9396) was found between the measured and literature values. In addition, several proprietary compounds were assayed using both the new and traditional methods and the measured partitioning ratios from the two methods are equivalent. The experiments in this work demonstrate that the LC/MS/MS-based depletion method can provide direct and accurate measurement of RBC partitioning for compounds in drug discovery.  相似文献   

10.
A sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed to determine carbocysteine in human plasma using 2-pyridylacetic acid as the internal standard (IS). The method employed derivatization with 10 M hydrochloric acid/methanol, which significantly improved the ionization efficiency of carbocysteine. After methanol-induced protein precipitation of plasma samples, carbocysteine and the IS were derivatized and subjected to LC/MS/MS analysis using atmospheric pressure chemical ionization. The method has a lower limit of quantitation of 20 ng/mL for a 0.2-mL plasma aliquot. The intra- and inter-day precision (RSD), calculated from quality control (QC) samples, was less than 7%. The accuracy, determined using QC samples, was within +/- 1%. The method offered increased sensitivity, selectivity and speed of analysis over existing methods. The method was utilized to support clinical pharmacokinetic studies of carbocysteine in volunteers following oral administration.  相似文献   

11.
A highly sensitive and selective method using liquid chromatography coupled with tandem mass spectrometry (LC/MS/MS) was developed and validated for the measurement of three antiretroviral agents, efavirenz, lopinavir and ritonavir, in human hair. Hair samples from adherent HIV-infected patients on antiretroviral therapies were cut into about 1 mm length segments and drugs were extracted by first shaking the samples with methanol in a 37 degrees C water bath overnight (>14 h), followed by methyl tert-butyl ether/ethyl acetate (1:1) extraction under weak alkaline conditions. The extracted lopinavir and ritonavir were separated by reversed-phase chromatography and detected by tandem mass spectrometry in electrospray positive ionization mode with multiple reaction monitoring (MRM), while efavirenz was monitored in negative ionization MRM mode. This method was validated from 0.01 to 4.0 ng/mg hair for ritonavir and 0.05-20 ng/mg hair for lopinavir and efavirenz by using 2 mg of a human hair sample. The interday and intraday assay precision (coefficients of variation, CV) for spiked quality control (QC) samples at low, medium and high concentrations were within 15% and accuracy ranged from 89% to 110%. Assay reproducibility was also demonstrated by analysis of incurred hair QC samples (CV <14%). No significant matrix ionization suppression was observed. This developed method allowed for the monitoring of these target medications in the hair samples of HIV-infected women on antiretroviral therapy in an observational study using small amounts of hair.  相似文献   

12.
Zhang  Xianhua  Louie  Alexander  Li  Xiaohua  Shi  Robert  Kelley  Robin K.  Huang  Yong 《Chromatographia》2012,75(23):1405-1413

A simple, fast and sensitive LC–MS/MS method was developed and validated for the simultaneous determination of the concentrations of temsirolimus and its major metabolite, sirolimus, in human whole blood. The blood sample (100 μL) after adding temsirolimus-d7 and sirolimus-d3 internal standards was precipitated with 0.200 mL of methanol/0.300 M zinc sulfate (70/30, v/v), then analyzed by a Shimatzu LC system coupled to a Sciex API-5000 mass spectrometer. The chromatographic separation was carried out on a BDS Hypersil C8 column (50 × 3.0 mm, 5 μm) at 50 °C with a mobile phase composed of methanol/water/formic acid (72/28/0.1) (v/v/v) containing 2.50 mM ammonium acetate. Mass spectrometric detection was performed using electrospray positive ionization with multiple reaction monitoring mode. This method was validated from 0.250 to 100 ng mL−1 for temsirolimus and 0.100 to 40.0 ng mL−1 for sirolimus. The lower limits of quantitation were 0.25 ng mL−1 for temsirolimus and 0.1 ng mL−1 for sirolimus. The intra-day and inter-day precisions (CV %) of spiked quality control (QC) samples were less than 10.4 and 9.6 %, respectively. The accuracies as determined by the relative error for QC samples were less than 12.1 % for intra-day and 7.3 % for inter-day. No significant matrix effect was observed. This method has been successfully applied to analyze clinical pharmacokinetic study samples. The assay reproducibility was also demonstrated by using incurred samples.

  相似文献   

13.
A sensitive and specific liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed for the investigation of the pharmacokinetics of ketotifen and its major metabolite, ketotifen N-glucuronide, in human plasma. The plasma samples were treated by liquid-liquid extraction and analyzed using LC/MS/MS with an electrospray ionization interface. Diphenhydramine was used as the internal standard. The method had a lower limit of quantitation of 10 pg/mL for ketotifen, which offered increased sensitivity, selectivity and speed of analysis, compared with existing methods. The intra- and inter-day precision were measured to be below 8.2% and accuracy between -2.4% and 3.4% for all QC samples. Incubation of the plasma samples with beta-glucuronidase allowed the quantitation of ketotifen N-glucuronide. This quantitation method was successfully applied to a pharmacokinetic study of ketotifen and its major metabolite after oral administration of 2 mg ketotifen fumarate to 16 healthy volunteers.  相似文献   

14.
A sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for determining the type B fumonisin mycotoxins in corn-based foodstuffs is described. Fumonisins FB1 and FB2 were extracted from a 1 g sample by homogenization with acetonitrile/water (75:25, v/v, 50 mmol/L formic acid, 25 mL final volume) and the extract was defatted on C18 phase. Volumes of 5 mL of crude extracts were cleaned up on Carbograph-4 cartridges. The final solution was analyzed by HPLC with electrospray ionization mass spectrometry in positive ion mode using multiple reaction monitoring with a QqQ linear ion trap mass spectrometer. Recoveries for spiked corn-based foodstuffs ranged from 91-105% (RSD% < or =8%), and method detection limits were < or =2 ng/g for FB1 and < or =1 ng/g for FB2. Two different spiking levels were tested (5000 and 100 ng/g for FB1, 1000 and 20 ng/g for FB2). Quantitation was achieved by an external calibration procedure using matrix-matched standards, with diclofenac added post-cleanup as internal standard for the LC/MS/MS analyses. Calibration curves showed linearity in the concentration range 0.005-5 ng/microL of final extract (0.992 < or = R2< or =0.995). Two other fumonisins, FB3 and FB4, were identified in naturally contaminated samples of corn meal using an information-dependent acquisition protocol that looped three experiments, including neutral loss scan, enhanced resolution scan, and enhanced product ion scan. FB3 and FB4 quantitation was estimated as peak area ratios relative to the FB2 response in view of the lack of both standards. This work also includes an application of the present LC/MS/MS method to some maize and maize-based product samples (corn meal, cornflakes and popcorn) collected from Italian stores. FB1 and FB2 contamination levels exceeding the European Union recommendation were found in 8 out of 15 corn meal samples.  相似文献   

15.
In the early stage of drug discovery, thousands of new chemical entities (NCEs) may be screened before a single drug candidate can be identified for development. In order to accelerate the drug discovery process, we have developed higher-throughput enzyme assays to evaluate the inhibition of cytochrome P450 isoforms 2D6 (CYP2D6) and 3A4 (CYP3A4) in human liver microsomes. The assays are based on high-performance liquid chromatography/tandem mass spectrometry (LC/MS/MS) techniques. The analysis time for each sample was reduced from approximately 20 minutes for the conventional HPLC assay to 30 seconds for the LC/MS/MS assay. For both LC/MS/MS assays, the linearity (r(2) > 0.99), precision (%CV < 15%) and accuracy (% bias <15%) for both inter- and intraday validations were satisfactory. Since the implementation of the LC/MS/MS assays, our sample throughput has increased by over 40-fold.  相似文献   

16.
A simple, fast and sensitive LC?CMS/MS method was developed and validated for the simultaneous determination of the concentrations of temsirolimus and its major metabolite, sirolimus, in human whole blood. The blood sample (100???L) after adding temsirolimus-d7 and sirolimus-d3 internal standards was precipitated with 0.200?mL of methanol/0.300?M zinc sulfate (70/30, v/v), then analyzed by a Shimatzu LC system coupled to a Sciex API-5000 mass spectrometer. The chromatographic separation was carried out on a BDS Hypersil C8 column (50?×?3.0?mm, 5???m) at 50?°C with a mobile phase composed of methanol/water/formic acid (72/28/0.1) (v/v/v) containing 2.50?mM ammonium acetate. Mass spectrometric detection was performed using electrospray positive ionization with multiple reaction monitoring mode. This method was validated from 0.250 to 100?ng?mL?1 for temsirolimus and 0.100 to 40.0?ng?mL?1 for sirolimus. The lower limits of quantitation were 0.25?ng?mL?1 for temsirolimus and 0.1?ng?mL?1 for sirolimus. The intra-day and inter-day precisions (CV?%) of spiked quality control (QC) samples were less than 10.4 and 9.6?%, respectively. The accuracies as determined by the relative error for QC samples were less than 12.1?% for intra-day and 7.3?% for inter-day. No significant matrix effect was observed. This method has been successfully applied to analyze clinical pharmacokinetic study samples. The assay reproducibility was also demonstrated by using incurred samples.  相似文献   

17.
Automated chip-based infusion nanoelectrospray ionization coupled to tandem mass spectrometry (nanoESI-MS/MS) was used to validate a bioanalytical assay conforming to United States Food and Drug Administration (FDA) regulatory guidelines and Good Laboratory Practices (GLP). Reboxetine was used as the analyte fortified in dog plasma along with an analog internal standard (IS). The best nanoESI response for reboxetine was observed with 90% acetonitrile (ACN)/water without any mobile phase modifiers. The analyte and IS were extracted from dog plasma samples by liquid-liquid extraction (LLE). The supernatant was concentrated to dryness and redissolved in 90% ACN/water for nanoESI. Selected reaction monitoring (SRM) data were collected for all samples to generate ion current profiles with a base width of approximately 20 s. Selectivity experiments showed no interferences in blank plasma samples. Interferences as a result of in-source collision-induced dissociation of metabolites were not an issue due to the previously documented metabolism of reboxetine. Matrix suppression was evaluated across multiple lots of dog plasma as well as over different animal species (rabbit, rat, mouse) and different anticoagulants (heparin, EDTA). Matrix suppression ranged from approximately 30-60% across the different lots, species etc.; however, in all instances, the analyte and the IS were suppressed by similar amounts, suggesting the similarity in ionization properties between the two. A three-batch validation was performed (each batch consisting of four different concentrations, six replicates of each concentration) and demonstrated inter-assay accuracy (% relative error; RE) of less than +/-8% and an inter-assay precision (% relative standard deviation; RSD) of less than 7%, thus meeting regulatory guidelines. A comparison of analyses by nanoESI-MS/MS and liquid chromatography coupled to tandem mass spectrometry (LC/MS/MS) showed that nanoESI-MS/MS had a greater slope for the calibration standard curve compared to LC/MS/MS, indicating greater sensitivity for the former technique. It is also noteworthy that the amount of sample infused during nanoESI-MS/MS was approximately 80-fold less compared to the amount of sample injected during LC/MS/MS. The absence of carryover (attributed to the lack of a common fluid path) in the nanoESI technique enabled the extension of the assay linear dynamic range to 500,000-fold, and the possibility of analyzing samples in a single batch without the need for re-analysis of samples with high concentrations. This technology offers the possibility for increased throughput for studies supporting drug development by providing fast data turnaround for assays conforming to regulatory guidelines and GLPs.  相似文献   

18.
A bioanalytical method for the quantification of tacrolimus (TAC) on dried blood spots (DBS) using liquid chromatography, electrospray ionization coupled with tandem mass spectrometry (LC‐ESI‐MS/MS) was developed and validated. It involves solvent extraction of a punch disk of DBS followed by liquid–liquid extraction. The analyte and the internal standard (IS, ascomycin) were separated on a phenyl column using an isocratic mobile phase elution at a flow rate of 0.3 mL/min. The assay was linear from 1 to 80 ng/mL. The mean recovery of TAC was 76.6%. Intra‐assay, inter‐assay imprecision and biases were all less than 15%. TAC on DBS was stable for at least 10 days at room temperature, and at least 24 h at 50°C. A chromatographic effect of the filter paper (Whatman 903) was not detected. The volume of blood (15–50 μL) and hematocrit of blood (ranging from 23.2 to 48.6%) did not show a significant influence on detection of TAC concentration by DBS‐LC‐MS/MS. Fifty samples from patients were detected by both DBS‐LC‐MS/MS and microparticle enzyme‐linked immunoassay (MEIA). TAC concentrations measured by DBS‐LC‐MS/MS method tended to be lower than those by MEIA. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

19.
LC-MS/MS has been widely applied to the quantitative analysis of tissue samples. However, one key remaining issue is that the extraction recovery of analyte from spiked tissue calibration standard and quality control samples (QCs) may not accurately represent the “true” recovery of analyte from incurred tissue samples. This may affect the accuracy of LC-MS/MS tissue bioanalysis. Here, we investigated whether the recovery determined using tissue QCs by LC-MS/MS can accurately represent the “true” recovery from incurred tissue samples using two model compounds: BMS-986104, a S1P1 receptor modulator drug candidate, and its phosphate metabolite, BMS-986104-P. We first developed a novel acid and surfactant assisted protein precipitation method for the extraction of BMS-986104 and BMS-986104-P from rat tissues, and determined their recoveries using tissue QCs by LC-MS/MS. We then used radioactive incurred samples from rats dosed with 3H-labeled BMS-986104 to determine the absolute total radioactivity recovery in six different tissues. The recoveries determined using tissue QCs and incurred samples matched with each other very well. The results demonstrated that, in this assay, tissue QCs accurately represented the incurred tissue samples to determine the “true” recovery, and LC-MS/MS assay was accurate for tissue bioanalysis. Another aspect we investigated is how the tissue QCs should be prepared to better represent the incurred tissue samples. We compared two different QC preparation methods (analyte spiked in tissue homogenates or in intact tissues) and demonstrated that the two methods had no significant difference when a good sample preparation was in place. The developed assay showed excellent accuracy and precision, and was successfully applied to the quantitative determination of BMS-986104 and BMS-986104-P in tissues in a rat toxicology study.  相似文献   

20.
A fast and sensitive liquid chromatography/triple quadrupole tandem mass spectrometry (LC/MS/MS) method was developed for the simultaneous determination of morphine, codeine, 6‐acetylmorphine (6‐AM), cocaine and benzoylecgonine (BE) in hair. Pulverized hair samples were extracted with methanol, and a 50 µL supernatant aliquot was injected into the LC/MS/MS system. Chromatography was performed with an XBridge? phenyl column (3.5 µm particle size, 4.6 × 150 mm), and the mobile phase was composed of methanol and 10 mM ammonium acetate adjusted to pH 4.00 with 99% formic acid (95:5, v/v). A separation run with isocratic elution was completed in 10 min at a flow rate of 500 µL/min. Positive electrospray ionization and multiple reaction monitoring (MRM) with one precursor ion/product ion transition were used for the identification of each analyte. Deuterated analogues as internal standards were used for quantification and qualification. Linearity was established in the concentration range of 100–3000 pg/mg. The limits of detection were 10 pg/mg for morphine, codeine and 6‐AM; and 1 pg/mg for cocaine and BE. The precision and accuracy were determined by spiking hair samples at six concentration levels. For all analytes, the relative standard deviations of intra‐ and inter‐day precision were 0.1–6.3% and 1.5–10.6%, respectively. The accuracy ranged from 92.7 to 109.7%. The validated LC/MS/MS method was successfully applied to the analysis of 79 authentic hair samples. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏