首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The analytical potential of a fast neutron reactor has been studied. The maximum density of the neutron flux is 2.5·1015 cm–2·s–1 at a maximum energy of 450 keV. The determining reaction for activation analysis at this reactor is an (n, n) reaction. The possibility of selectively determining Pb, Hg, Cd, Au, Ag and other elements at a level of 10–5–10–8% is demonstrated. This activation technique allows rapid determination of these elements.  相似文献   

2.
For determining low level lithium concentrations in water, a neutron activation method based on the measurement of tritium radioactivity produced by6Li(n,)3H reaction has been developed. This method is specific and free from interference by other chemical elements. Using a low background liquid scintillation counter for tritium measurement, the detection limit is approximately 0.3 ppm during irradiation at a thermal neutron flux density of 1.1·107n·cm–2·s–1 for 6 hours by a small nuclear reactor and liquid scintillation counting for 2000 minutes  相似文献   

3.
In determining the trace platinum group elements and gold in rocks and ores by the neutron activation analysis after a nickel sulphide fire assay preconcentration, there are interferences due to nuclides produced from second order nuclear reactions. This paper presents the degree of interference calculated over the ranges of long irradiation times and of reactor neutron flux from 1·1013 to 1·1015 n·cm–2·s–1. According to the results of these calculations, every one of the second order interfering reactions on the PGE+Au, except the197Au(n, )198Au(n, )199Au reaction, can be neglected under the long irradiation time or high reactor neutron flux. Special attention is given to the interference from gold in the determining platinum.  相似文献   

4.
The concentration of rare earths and other elements have been determined in the bed sediment samples of Karnafuli estuarine zone in the Bay of Bengal by instrumental neutron activation analysis (INAA). The samples and the standards soil-5, soil-7, coal fly ash and pond sediment were prepared and simultaneously irradiated for short and long time at the TRIGA Mark-II research reactor facility of Atomic Energy Research Establishment, Savar, Dhaka. The maximum themal neutron flux was of the order of 1013 n·cm–2·s–1. After irradiation the radioactivity of the product nuclides was measured by using a high resolution high purity germanium detector system. Analysis of -ray spectra and quantitative analysis of the elemental concentration were done via the software GANAAS, it has been possible to determine the concentration level of 27 elements including the rare earths La, Ce, Sm, Eu, Tb, Dy and Yb and uranium and thorium.  相似文献   

5.
In order to assess the source of pollutants and the atmosphere quality in and around a thermal power plant, fugitive dust particulates from seven different locations and ambient air dust from six locations have been analyzed for 32 elements (As, Au, Ba, Br, Ce, Cl, Co, Cr, Cs, Cu, Eu, Fe, Ga, Hg, Hf, K, La, Lu, Mg, Mn, Na, P, Rb, Sb, Sc, Se, Ta, Tb, Te, Th, W and Yb) by employing instrumental neutron activation analysis (INAA). The method involves the irradiation of samples and comparator standards in a thermal neutron flux range of 1012–1013 n·cm–2·s–1 in a nuclear reactor for 10 min and 1 day followed by high resolution -spectrometry. Wide differences have been observed in the mean elemental concentrations of Fe, Co, Br, Mn, As, P. Ba and Cu in fugitive and ambient dust particulates coliected from these different locations. Further, a comparison of the elemental contents of the dust particulates from the plant with environmental standards (Urban Particulate Matter, Coal Fly Ash, Vehicle Exhaust and Coal) show significantly lower or comparable amounts of toxic and pollutant elements in the environmental samples.  相似文献   

6.
24 male autopsy cases aged 35–60 years have been collected from Shanghai China to study the relationships between human hair and internal tissues. Autopsy samples of hair, kidney-cortex, liver and lung were analyzed. A radiochemical neutron activation analysis (RNAA) based on a simple group extraction scheme was used for measuring the trace elements As, Cd, Hg, Cu and Zn. Zinc diethyldithiocarbamate Zn(DDC)2 and methly isobutyl ketone-iodide have been chosen as reagent. Trace element of Se was determined by instrumental neutron activation analysis (INAA). A SLOWPOKE reactor with a thermal neutron flux of 8·1011 n·cm–2·s–1 and a swimming pool type reactor with a thermal neutron flux of 1·1013 n·cm–2·s–1 were used for short and long irradiation of samples, respectively. The reliability of methods has been checked by analyzing biological standard reference materials Horse Kidney (IAEA H8), Tomato Leaves (NBS 1573) and Human Hair (NIES-5). The analytical results show that toxic elements As, Cd and Hg exist in a larger individual variability than the essential elements of Cu, Se and Zn for each tissue. A linear regression analysis related to the six elements of primary interest for the IAEA Coordinated Research Program (CRP) has been done by a computer program for each pair of hair-tissue. A positive correlation is found between concentration of As in hair and kidney-cortex, the correlation coefficient r is 0.751 (p<0.01). Positive correlations between concentration of Se in hair and liver, kidney-cortex and lung are also observed in this study. It shows that the elements As and Se in hair may be useful indicators for assessing certain internal tissues of normal persons. A comparison of Cd concentration in lung shows a significant difference between smokers and non-smokers. A significant correlation between element Cd and Zn in kidney-cortex is also presented in this paper.  相似文献   

7.
The trace elements content of Cola acuminata and three varieties of Cola nitida have been determined using neutron activation analysis. The samples have been irradiated at the Joint Universities Research Reactor, Risley, England for 71/2 hours in a neutron flux of 2.5·1012 n·cm–2s–1 and analysed using high resolution lithium drifted germanium detector coupled to a Canberra 35 microprocessor as a 4096 channel gamma spectrometer. The elements: Na, K, Br, W, Fe, Cs, Co, Zn, and Sc were detected.  相似文献   

8.
An RNAA procedure has been developed for measurement of low-level phosphorus in metals. Samples are irradiated at a neutron flux of 2.7·1013 n·cm–2·s–1 then mixed with carrier and dissolved in acid. After chemical separation and purification of the phosphorus and gravimetric determination of carrier yield, 32P is determined using a beta proportional counter. The detection limit for a 0.1 g sample irradiated for 30 minutes is 5 g/kg. The method has been used to determine 6.4±0.6 mg/kg phosphorus in SRM 2175 refractory alloy.  相似文献   

9.
The design features are described of a prompt gamma neutron activation analysis system at HANARO, a 30 MW research reactor in the Korea Atomic Energy Research Institute. The beam consists of polychromatic thermal neutrons diffracted by a set of pyrolytic graphite crystals at orders n in the range 1n6 at a Bragg angle of 45° on a horizontal beam line. A neutron flux of 1.0·108 n·cm–2·s–1 is calculated at the sample position from the reflectivity of the crystal which has been confirmed in a measurement of a diffracted neutron spectrum using a time-of-flight spectrometer and gold-wire activation. The fast neutron and gamma backgrounds will be low due to the use of a diffracted beam and a tapered collimator. The detection system comprises a 30% n-type HPGe detector, signal electronics and a fast ADC. The first application of this system will be the analysis of boron concentration in biological samples for neutron capture therapy. Construction of the beam line and the arrangement of the detection system is proceeding.  相似文献   

10.
The application of stable isotope analysis using neutron-induced prompt -ray analysis (PGA) with cold/thermal neutron beams for the tracer study of geological materials are discussed. Silicon has three natural isotopes differing in abundance:28Si (92.23%),29Si (4.67%) and30Si (3.10%). For the purpose of the assessment of Si migration in engineered barrier material, enriched30Si can be used as a tracer due to its nuclear and chemical properties. Isotope analysis of30Si was performed by PGA during the tracer study. Neutron intensity at the sample position was 1.4·108 n¢cm–2·s–1, 2.4·107 n·cm–2·s–1 for cold and themal neutron guided beams of JRR-3M, respectively. Calibration curves and analytical sensitivity of30Si were determined based on measurement of standard samples. BG and detection limits for30Si analysis were also measured in Japanese bentonite (Kunigel V1 and Kunipia F) and their pore water. Fiffteen elements were determined simultaneously using PGA.  相似文献   

11.
This work describes the design, fabrication, and testing of a lucite bodied proportional gas detection system for the analysis of boron in selected samples via detection of the charged particles produced in the 10B(n,)7Li reaction induced by thermal neutrons. The detector was designed for internal placement of samples; the sample types of major interest were airborne aerosols collected on filters or particulate impaction plates. Samples were irradiated with the detector in the thermal neutron field produced in the graphite thermal column of the University of Lowell's one megawatt research reactor. Determined sensitivities for boron varied from 6.2·10–8 to 1.73·10–6 cpm·ng–1 (n·cm–2J·s–1)–1 depending on the physical characteristics of the samples. For a nominal counting time of ten minutes the lower limit of mass detection of natural boron was determined to be 12.1 nanograms. The analytical method was applied to the estimation of boron in fourteen samples of natural aerosols collected on membrane filters. Analysis of prepared samples and natural aerosol samples by ICP emission showed good agreement with analysis via the (n,) reaction. Application of the method to other sample types was demonstrated by the determination of boron in samples of borosilicate glass and borated polyethylene.  相似文献   

12.
The separation of fluoride by extraction with toluene solution of triphenyltin chloride has been studied. Quantitative isolation of fluoride from solutions with a wide acidity range (pH 4.0–11.5) has been established. It is suggested that interferences by Ca, Mg, Fe, and Al can be avoided by masking these elements using sulfate and hydroxyde ions. Interference by phosphate ions can be overcome in a similar fashion. The halogenated species can be masked by mercury nitrate. Detection limit for fluorine determination is about 3 g for a neutron generator flux of 2·1111 n·cm–1·s–1. A method for fluorine assay in water using a neutron generator with a detection limit of 1 ppm has been developed.  相似文献   

13.
Elemental profiles of brain tumor tissues from 15 patients of astrocytomas (grade I–III) and normal human brain tissues of 23 male age matched autopsies as controls have been studied by instrumental neutron activation analysis. The SLOWPOKE reactor with a thermal neutron flux of 8·1011n·cm–2·s–1 and swimming pool type reactor with a thermal neutron flux of 1·1013n·cm–2·s–1 were used for short and long irradiation of samples, respectively. Spectrophotometry was only used for analyzing phosphorus. A total of 18 elements Se, Na, K, Br, Cl, Mn, Mg, S, Ca, Cu, Hg, Cr, Fe, Rb, Zn, Co, Sc and P has been determined for this purpose. The reliability of methods has been checked by analyzing biological standard reference materials horse kidney (IAEA H-8) and bovine liver (NBS SRM 1577a). The analytical results showed that compared with the normal brain tissues, concentrations of Ca, Fe, Cu, Zn, Se, Mn, Br and Sc were significantly higher in tumor tissues (P<0.01) and concentrations of Rb, K and P were lower, while no differences for contents of Mg, S, Cr, Hg, Na and Cl were observed. A negative correlation between P and Ca in malignant and normal brain tissues was observed.  相似文献   

14.
A method for the determination of boron concentration in extracted (NH4)2 U2O7·H2O (ADU) has been used. One ml of the aqueous solution is irradiated with thermal neutrons from a 10 Ci Am/Be neutron source with a flux of 0.2·105 n·cm–2·s–1 and thermal column in the IRT-5000 with a flux of about 107 n·cm–2·s–1. The alpha-activity due to the reaction10B(n, )7Li is recorded by a CR-39 alpha track detector. After the exposure, the alpha tracks are made visible in an optical microscope at magnification of 800X by etching the detector in 6N NaOH, and the track density is determined using calibration curves of known concentrations of boron. The boron concentration of the extracted ADU was found to be 5 ppm.  相似文献   

15.
Instrumental neutron activation analysis technique was applied for the determination of 20 elements in 54 silicate rock samples which belong to three sedimentary geological formations located in the western desert of Iraq. The samples along with USGS standards were irradiated in an IRT-5000 reactor at a neutron flux of 3.7·1013 n·cm–2·s–1 The following minor and trace element constituents have been determined: Na, K, Ca, Fe, Sc, Cr, Co, Zr, Ce, La, Nd, Sm, Eu, Tb, Yb, Lu, Hf, Ta, Th and U.  相似文献   

16.
Neutron activation analysis of major and trace elements in crude petroleum   总被引:1,自引:0,他引:1  
We have determined the concentration of 25 trace elements in crude petroleum from seven Libyan oil fields by instrumental neutron activation analysis. Crude oil samples were irradiated with a thermal neutron dose rate of 1012 and 1013 n·cm–2·s–1 in the Tajoura research reactor. The concentration of U, Br, Mg, Cu, Na, V, Cl, Al, Mn and Ca is in a range of 0.015 to 84 ppm and that of sulphur of 0.12 to 1.8%. The elements Sc, Cr, Ni, Fe, Co, Zn, Ag, Se, Sb, Ba, Cs, Yb, Hf and Hg have a concentration range of 0.009 to 8747 ppb. The coefficients of variation are within 10%. The elements V and Ni occur as both porphyrin and non-porphyrin and the ratio of these two forms varies over a wide range. The V/Ni ratios are located between 0.17 and 6.67, which are comparable to the reported values for the crude oils from other countries.  相似文献   

17.
PVC samples were irradiated for 1 hour with a thermal neutron flux of th =4.71·1011n·cm–2·s–1 and the chlorine lost during irradiation was measured by -ray spectrometry. About 15% of loss of chlorine has been observed for untreated samples while samples heated to temperatures of 60 and 80°C for one minute before irradiation have been found to loose about 8% and 3%, respectively. The results indicate an influence of the polymer structure on the release of chlorine.  相似文献   

18.
Spectral studies of morin in aqueous ethanol and other alcohols have been carried out as a function of its concentration and that of ethanol, and the pH of aqueous buffer. The effect of gamma radiations on morin solution in ethanol was also studied as a function of dose in the range of 0.15–2.28 kGy and of morin concentration (10–5–10–4 mole·dm–3). Morin concentration in ethanol solution showed a linear response for G values to a dose of 1.83 kGy. Molar absorption coefficients () for morin in ethanol have been estimated to be 260nm=2.28·104 dm3·mol–1·cm–1 and 291nm=8.22·103 dm3·mol–1·cm–1 for unirradiated and 291 nm=1.75·104 dm3·mol–1·cm–1 for irradiated solutions to a dose of 1.83 kGy.  相似文献   

19.
GaAs is not an ideal matrix for INAA because elements yielding activation products with half-lives up to about 5 d cannot be measured due to the interference by72Ga and76As (t1/2=14.1 h and 26.4 h, respectively). The measurement of radionuclides with longer half-lives is interfered with by74As (t1/2=17.7 d), generated by fast neutrons. However, using an irradiation facility with a very low flux of fast neutrons, in which the generation of74As is minimal, five elements could be determined in GaAs (Cr, Co, Zn, Ag, and Hg). For 27 elements the detection limits were below 1 g/g and for ten of them below 10 ng/g. The determination of nitrogen in GaAs has been carried out using the (n, p)-reaction on14N, which is induced by thermal neutrons. The activation product,14C, can be effectively separated and purified via14CO2 and counted with high efficiency in a liquid scintillation counter, and nitrogen can be determined with fairly low detection limits if sufficiently high neutron fluxes and long irradiation times are applied. The procedure described is based on a reactor irradiation with a thermal flux of 2·1014 n·cm–2·s–1 for 51 days. 0.16±0.09 g/g N in GaAs were determined and the detection limit was about 3 ng/g.  相似文献   

20.
A rapid method for the determination of Al, V and Ti has been developed and is used for the analysis of these elements in different ores and alloys. An isotopic neutron source252Cf having a thermal neutron flux of the order of 8.5×107 n·cm–2 sec–1 has been used for thermal neutron bombardment. Activity measurements were performed on a HPGe detector coupled to a PC based MCA unit. Depending on the half-life of the (n, ) product, different irradiation and cooling times were employed and thus the elements of interest were analyzed sequentially.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号