首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
《Analytical letters》2012,45(8):1119-1135
Abstract

A solid graphite–polyurethane composite electrode has been used to determine release profiles of verapamil, a calcium-channel blocker. The electro-oxidation process was characterized by cyclic voltammetry and electrochemical impedance spectroscopy and showed no adsorption of analyte or oxidation products, unlike at other carbon-based electrodes. Quantification gave linear ranges up to 40 µmol L?1 with cyclic voltammetry and detection limits of 0.7 µmol L?1 by differential pulse and square-wave voltammetry. Commercial product samples were successfully analyzed with results equal to those from spectrophotometry. Because no electrode surface renewal is needed, this electrode material has many advantages.  相似文献   

2.
《Analytical letters》2012,45(4):593-598
Abstract

The nickel hydroxide–modified nickel (NMN) electrode was prepared by cyclic voltammetry. The modified electrode exhibited better catalytic effect toward electrochemical oxidation of methane in 1.0 mol · L?1 NaOH solution. The catalytic activation of nickel hydroxide on the nickel electrode surface was investigated in different supporting electrolyte solutions by the cyclic voltammetry method in detail, and the related electrochemical oxidation of methane at the NMN electrode was first proposed by amperometric i‐t curve method under the experiment conditions. The results indicated that in the 1.0 mol · L?1 NaOH solution, the anodic peak current increased with the increased concentration of methane.  相似文献   

3.
The electrochemical behavior of L ‐cysteine studied at the surface of ferrocenedicarboxylic acid modified carbon paste electrode (FDCMCPE) in aqueous media using cyclic voltammetry, differential pulse voltammetry and double potential step chronoamperometry. It has been found that under optimum condition (pH 8.00) in cyclic voltammetry, the oxidation of L ‐cysteine occurs at a potential about 200 mV less positive than that of an unmodified carbon paste electrode. The kinetic parameters such as electron transfer coefficient, α, and catalytic reaction rate constant, kh were also determined using electrochemical approaches. The electrocatalytic oxidation peak current of L ‐cysteine showed a linear dependent on the L ‐cysteine concentration and linear analytical curves were obtained in the ranges of 3.0×10?5 M–2.2×10?3 M and 1.5×10?5 M–3.2×10?3 M of L ‐cysteine concentration with cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods respectively. The detection limits (3σ) were determined as 2.6×10?5 M and 1.4×10?6 M by CV and DPV methods.  相似文献   

4.
The electrochemical response of a modified-carbon nanotubes paste electrode with p-aminophenol was investigated as an electrochemical sensor for sulfite determination. The electrochemical behaviour of sulfite was studied at the surface of the modified electrode in aqueous media using cyclic voltammetry and square wave voltammetry. It has been found that under the optimum condition (pH 7.0) in cyclic voltammetry, the oxidation of sulfite occurs at a potential about 680?mV less positive than that of an unmodified-carbon nanotubes paste electrode. Under the optimized conditions, the electrocatalytic peak current showed linear relationship with sulfite concentration in the range of 2.0?×?10?7–2.8?×?10?4?mol?L?1 with a detection limit of 9.0?×?10?8?mol?L?1 sulfite. The relative standard deviations for ten successive assays of 1.0 and 50.0?µmol?L?1 sulfite were 2.5% and 2.1%, respectively. Finally, the modified electrode was examined as a selective, simple and precise new electrochemical sensor for the determination of sulfite in water and wastewater samples.  相似文献   

5.
The electrochemical behaviour of dopamine (DA) at a cleaned and alumina polished glassy carbon electrode (GCE) was studied using cyclic voltammetry (CV). The CV studies revealed that alumina polished GCE (AGCE) shows an enhanced oxidation peak current response with 217 mV negative potential shift towards DA than that of cleaned GCE. The differential pulse voltammetry result shows that the AGCE detects the DA in the linear concentration ranges from 0.15 to 25.25 µmol L?1. The limit of detection was calculated as 0.046 µmol L?1 with a sensitivity of 3.74 µA µmol L?1 cm?2 for the determination of DA. The fabricated AGCE shows a satisfactory selectivity, practicality along with appreciable repeatability and reproducibility.  相似文献   

6.
A sensitive way to determine levofloxacin using a sensor based on vertical aligned carbon nanotubes is described. The morphology and the electrochemical performance of the electrodes were characterised by atomic force microscopy, cyclic voltammetry and square wave voltammetry. A scan‐rate study and electrochemical impedance spectroscopy showed that the levofloxacin oxidation product is adsorbed on the electrode surface. Differential pulse voltammetry in phosphate‐buffer solution allowed the development of a method to determine levofloxacin levels in the range of 1.0–10.0 µmol L?1, with a detection limit of 75.2 nmol L?1. The proposed sensor was successfully applied in the determination of levofloxacin in urine, and the obtained results were in full agreement with those from the HPLC procedure.  相似文献   

7.
In this work, thionine (Th) was assembled on the surface of graphene oxide as an electron transfer mediator using diazonium reaction (Th–GO). Then, Th–GO was characterized by different methods such as scanning electron microscopy, transmission electron microscopy, and Fourier transform infrared spectroscopy. Afterward, Th–GO was used for the modification of carbon paste electrode. Several electrochemical methods including cyclic voltammetry, differential pulse voltammetry, and hydrodynamic amperometry were used to investigate the behavior of the modified electrode. Then, the role of the modified electrode for oxidation of nitrite has been studied. For this purpose, the effect of critical experimental parameters including step potential and pulse amplitude (in differential pulse voltammetry technique), applied potential, the rotating speed of the disk (in amperometry technique), and the solution pH was investigated. Under the optimized conditions, the currents were found to be linear with the nitrite concentration in the range 0.05–33.0 and 0.5–800 µmol L?1 with detection limits of 0.02 and 0.2 µmol L?1 using differential pulse voltammetry and hydrodynamic amperometry, respectively. The introduced modified electrode showed good repeatability (RSD% = 3.2) and reproducibility (RSD% = 4.7). This electrochemical sensor was exerted successfully for the determination of nitrite and nitrate in real samples including water and wastewater samples.  相似文献   

8.
In the present study a glassy carbon electrode, modified with nanocomposite of gold nanoparticles/multiwalled carbon nanotubes (GNPs/MWCNTs/GCE), was used for determination of dicyclomine hydrochloride (DcCl). The results showed that synergetic effects of GNPs and MWCNTs highly improved electrochemical response and sensitivity of the sensor. The electrochemical oxidation of DcCl was investigated by cyclic voltammetry and differential pulse voltammetry. Also, scanning electron microscopy and energy dispersive x-ray spectroscopy were used to evaluate microstructure of electrochemical sensor. The effect of various experimental parameters including pH and scan rate on the voltammetric response of DcCl were investigated. Under the optimal conditions linear response was observed in range of 1.0–1.2 × 102 µmol L?1 for DcCl. The lower detection limit was found to be 0.40 µmol L?1 for DcCl. The investigated method showed good stability, reproducibility and repeatability. The proposed sensor was successfully applied to the determination of DcCl in real samples.  相似文献   

9.
A self-assembled sensor based on a boron-doped diamond was investigated as a sensitive tool for voltammetric analysis of a member of a pyridine herbicide family - picloram. A cyclic voltammetry and a differential pulse voltammetry were applied for investigation of the voltammetric behaviour and quantification of this herbicide. Picloram yielded one well-developed irreversible oxidation signal at a very positive potential about +1.5 V vs. Ag/AgCl/3 mol L?1 KCl electrode in an acidic medium and 1 mol L?1 H2SO4 was chosen as a suitable supporting electrolyte. Operating parameters of differential pulse voltammetry were optimized and the proposed voltammetric method provided a high repeatability (a relative standard deviation of 20 repeated measurements at a concentration level of picloram of 50 µmol L?1 equaled to 2.58%), a linear concentration range from 2.5 to 90.9 µmol L?1 and a low limit of detection (LD = 1.64 µmol L?1). Practical usefulness of the ‘environmentally-green’ electrochemical sensor was verified by an analysis of spiked water samples with satisfactory recoveries.  相似文献   

10.
《Analytical letters》2012,45(11):1454-1466
A multiwall carbon nanotube/silicone rubber (MWCNT/SR) composite electrode has been used for the determination of hydrochlorothiazide (HCTZ) in pharmaceutical formulations by differential pulse voltammetry (DPV). The electro-oxidation process was evaluated by cyclic voltammetry, from which it was observed that HCTZ presents an irreversible oxidation peak at 0.82 V vs. saturated calomel electrode (SCE) in the potential range from 0.5 to 1.1 V, in Britton-Robinson buffer pH 7.0 at MWCNT/SR. HCTZ was determined by DPV using a MWCNT/SR 70% (MWCNT, m/m) composite electrode after the optimization of the experimental parameters. The linear range was from 5.0 to 70.0 µ mol L?1, with a limit of detection (LOD) of 2.6 µ mol L?1. The HCTZ was determined in pharmaceutical formulations using the proposed composite electrode and the results agreed with those from the official high performance liquid chromatography (HPLC) method within 95% confidence level, according to the t-Student test.  相似文献   

11.
An electrochemical biosensor was fabricated by covalent modification of 5-hydroxytryptophan (5-HTP) on the surface of glassy carbon electrode (GCE). The electrode, denoted as 5-HTP/GCE, was characterized by X-ray photoelectron spectroscopy, cyclic voltammetry and differential pulse voltammetry. For comparison, tryptophan modified GCE (TRP/GCE) and serotonin modified GCE (5-HT/GCE) were prepared by the same method. It was found that electrocatalytic ability of these electrodes was in the order of 5-HTP/GCE?>?TRP/GCE?>?5-HT/GCE for the oxidation of dopamine (DA) and 5-HT. The sensor was effective to simultaneously determine DA and 5-HT in a mixture. It can resolve the overlapping anodic peaks into two well-defined voltammetric peaks at 0.24 and 0.39 V (versus SCE). The linear response is in the range of 5.0?×?10?7–3.5?×?10?5 mol L?1 with a detection limit of 3.1?×?10?7 mol L?1 for DA, and in the range of 5.0?×?10?6–3.5?×?10?5 mol L?1 with a detection limit of 1.7?×?10?6 mol L?1 for 5-HT (s/n?=?3), respectively.  相似文献   

12.
A mesoporous silica-based hybrid material composed of silica xerogel modified with an ionic silsesquioxane, which contains the 1,4-diazoniabicyclo[2.2.2]octane chloride group, was obtained. The silsesquioxane film is highly dispersed on the surface. This hybrid material was utilized to develop a carbon paste electrode (CPE) for determination of methyl parathion. Transmission FTIR, elemental analysis and N2 adsorption–desorption isotherms were used for characterization of the material. The electrochemical behavior of methyl parathion was evaluated by cyclic voltammetry and differential pulse voltammetry. It was observed a linear response to methyl parathion in the concentration range from 1.25 × 10?7 to 2.56 × 10?6 mol L?1 by employing the carbon paste electrode, in Britton–Robinson buffer solution (pH 6). The achieved detection limit (3 SD of the blank divided by the slope of calibration curve) was 0.013 µmol L?1 and sensitivity was 6.3 µA µmol L?1. This result shows the potentiality of this electrode for application as electrochemical sensor for methyl parathion.  相似文献   

13.
This work describes the development, electrochemical characterization and utilization of a cobalt phthalocyanine modified carbon nanotube electrode for the quantitative determination of dopamine in 0.2 mol L?1 phosphate buffer contaminated with high concentration of ascorbic acid. The electrode surface was analyzed by cyclic voltammetry and electrochemical impedance spectroscopy which showed a modified surface presenting a charge transfer resistance of 500 Ω, against the 16.46 kΩ value found for the bare glassy carbon surface. A pseudo rate constant value of 5.4×10?4 cm s?1 for dopamine oxidation was calculated. Voltammetric experiments showed a shift of the peak potential of DA oxidation to less positive value at 390 mV as compared with that of a bare GC electrode at 570 mV. The electrochemical determination of dopamine, in presence of ascorbic acid in concentrations up to 0.1 mol L?1 by differential pulse voltammetry, yielded a detection limit as low as 2.56×10?7 mol L?1.  相似文献   

14.
《Analytical letters》2012,45(2):248-258
A poly(diallyldimethylammonium chloride)-graphene-multiwalled carbon nanotube modified glassy carbon electrode was fabricated and evaluated by cyclic voltammetry and differential pulse voltammetry. The modified electrode offered high sensitivity, selectivity, excellent long-term stability, and electrocatalytic activity for uric acid and dopamine. This sensor showed wide linear dynamic ranges of 5.0 to 350.0 µmol L?1 for uric acid and 10.0 to 400.0 µmol L?1 for dopamine in the presence of 500 µmol L?1 ascorbic acid. The limits of detection were 0.13 for uric acid and 0.55 µmol L?1 for dopamine. This functionalized electrode has potential application in bioanalysis and biomedicine.  相似文献   

15.
In this article, the utility of a boron-doped diamond electrode for the determination of the fungicide oxycarboxin is demonstrated. For the first time, the square-wave voltammetry was employed in a quantitative determination of oxycarboxin on the boron-doped diamond electrode. It was found that oxycarboxin displays a well-expressed oxidation peak at a potential of ca. +1.5 V vs. Ag/AgCl in Britton–Robinson buffer with the maximum response in pH 4.0. As observed in cyclic voltammetry, oxycarboxin undergoes diffusion-controlled irreversible electrochemical oxidation. At optimised square-wave voltammetry parameters, the current response of oxycarboxin was linearly proportional to its concentration in the wide linear dynamic range of 8.0–100.0 μmol L?1 (2.1–26.7 mg L?1). The developed electroanalytical method yielded a relatively low limit of detection of 1.6 μmol L?1 (0.4 mg L?1), associated with high repeatability of the peak current expressed as relative standard deviation in the range of 1.1–2.9% for each concentration of oxycarboxin solution. This simple and sensitive method was proved to be suitable for an analysis of spiked river water samples with satisfactory results (relative standard deviation of 1.4%, recovery of 100.2%). The impact of possible interferences was tested and evaluated, and obtained results proved good selectivity of the proposed method. In addition, the influence of oxycarboxin on the corrosion properties of AISI 316 L stainless steel used as a construction material in farming was tested using potentiodynamic method, and a corrosive damage was characterised by means of scanning electron microscopy.  相似文献   

16.
Gallic acid (GA), as a main phenolic acid, has been considered the main player on the human health, including the effects of reduction of cholesterol, depression of hypertension, anti-oxidation, anti-microbial, protection against cardiovascular disease and cancer. This study describes the development, electrochemical characterization and utilization of a novel functionalized graphene oxide/poly(p-aminohippuric acid)–sodium dodecyl sulfate nanocomposite modified glassy carbon electrode (APTS@GO/PPAH-SDS/GCE) for the electrocatalytic determination of GA. The synthesized nanocomposite was characterized by different techniques such as Fourier-transform infrared spectroscopy, thermo-gravimetric analysis and transmission electron microscopy. The electrochemical oxidation of GA was investigated by cyclic voltammetry, differential pulse voltammetry and amperometry. The modified electrode showed a potent and persistent electron mediating behavior followed by well-defined oxidation peak of GA and the linear range of 0.006–2000 µmol L?1 with a detection limit of 1.7 nmol L?1 for GA (S/N?=?3) using amperometric method. Also, it was successfully used for the GA determination in the black tea and tab water as real samples. Additionally, this electrode exhibited good stability and reproducibility. The results imply that the APTS@GO/PPAH-SDS nanocomposite might be a promising candidate for practical applications in GA electrochemical detection.  相似文献   

17.
A new composite electrode based on multiwall carbon nanotubes (MWCNT) and silicone‐rubber (SR) was developed and applied to the determination of propranolol in pharmaceutical formulations. The effect of using MWCNT/graphite mixtures in different proportions was also investigated. Cyclic voltammetry and electrochemical impedance spectroscopy were used for electrochemical characterization of different electrode compositions. Propranolol was determined using MWCNT/SR 70 % (m/m) electrodes with linear dynamic ranges up to 7.0 µmol L?1 by differential pulse and up to 5.4 µmol L?1 by square wave voltammetry, with LODs of 0.12 and 0.078 µmol L?1, respectively. Analysis of commercial samples agreed with that obtained by the official spectrophotometric method. The electrode is mechanically robust and presented reproducible results and a long useful life.  相似文献   

18.
Poly(2-amino-5-(4-pyridinyl)-1,3,4-thiadiazole) (PAPT) modified glassy carbon electrode (GCE) was fabricated and used for the simultaneous determinations of dopamine (DA), uric acid (UA) and nitrite (NO2 ?) in 0.1 mol?L?1 phosphate buffer solution (PBS, pH 5.0) by using cyclic voltammetry and differential pulse voltammetry (DPV) techniques. The results showed that the PAPT modified GCE (PAPT/GCE) not only exhibited electrocatalytic activities towards the oxidation of DA, UA and NO2 ? but also could resolve the overlapped voltammetric signals of DA, UA and NO2 ? at bare GCE into three strong and well-defined oxidation peaks with enhanced current responses. The peak potential separations are 130 mV for DA–UA and 380 mV for UA–NO2 ? using DPV, which are large enough for the simultaneous determinations of DA, UA and NO2 ?. Under the optimal conditions, the anodic peak currents were correspondent linearly to the concentrations of DA, UA and NO2 ? in the ranges of 0.95–380 μmol?L?1, 2.0–1,000 μmol?L?1 and 2.0–1,200 μmol?L?1 for DA, UA and NO2 ?, respectively. The correlation coefficients were 0.9989, 0.9970 and 0.9968, and the detection limits were 0.2, 0.35 and 0.6 μmol?L?1 for DA, UA and NO2 ?, respectively. In 0.1 mol?L?1 PBS pH 5.0, the PAPT film exhibited good electrochemical activity, showing a surface-controlled electrode process with the apparent heterogeneous electron transfer rate constant (k s) of 25.9 s?1 and the charge–transfer coefficient (α) of 0.49, and thus displayed the features of an electrocatalyst. Due to its high sensitivity, good selectivity and stability, the modified electrode had been successfully applied to the determination of analytes in serum and urine samples.  相似文献   

19.
《Analytical letters》2012,45(4):678-688
Abstract

MCM-41 was synthesized with uniform pore networks and then used to modify a carbon-paste electrode (CPE). The electrochemical behavior of rutin was investigated. Compared with the bare CPE, the MCM-41–modified CPE remarkably enhances the redox peak currents of rutin, attributed to large surface area, high sorption capacity, and specific mesopores. Based on this, a sensitive and convenient electrochemical method was developed for the analysis of rutin. The linear range is from 2.0 × 10?8 to 1.0 × 10?6 mol L?1, and the limit of detection is 1.5 × 10?8 mol L?1. Finally, this method was employed to determine rutin in traditional Chinese medicines.  相似文献   

20.
Yazhen Wang 《Mikrochimica acta》2011,172(3-4):419-424
The electrochemistry of uric acid at a gold electrode modified with a self-assembled film of L-cysteine was studied by cyclic voltammetry and differential pulse voltammetry. Compared to the bare gold electrode, uric acid showed better electrochemical response in that the anodic peak current is stronger and the peak potential is negatively shifted by about 100 mV. The effects of experimental conditions on the oxidation of uric acid were tested and a calibration plot was established. The differential pulse response to uric acid is linear in the concentration range from 1.0?×?10?6 to ~?1.0?×?10?4 mol?L?1 (r?=?0.9995) and from 1.0?×?10?4 to ~?5.0?×?10?4 mol?L?1 (r?=?0.9990), the detection limit being 1.0?×?10?7 mol?L?1 (at S/N?=?3). The high sensitivity and good selectivity of the electrode was demonstrated by its practical application to the determination of uric acid in urine samples.
Cyclic voltammograms of UA at the bare electrode (a,b) and the L-Cys/Au electrode (c,d,e) in HAc-NaAc buffer containing different concentrations of UA. (a,c): blank; (b, d): 2.0?×?10?5 mol?L?1; (e) 4.0?×?10?5 mol?L?1. Scan rate: 100 mV?s?1  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号