首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 453 毫秒
1.
A novel chemiluminescence (CL) system was established for the determination of puerarin in pharmaceutical preparations. It was shown that a strong CL signal was observed when Eosin Y reacted with the hydroxyl radicals which were generated from Fenton reagent in acidic medium. The CL intensity was decreased significantly when puerarin was added to the reaction system and partially scavenged the hydroxyl radicals in the solution. The extent of decrease in the CL intensity had a good stoichiometrical relationship with puerarin concentration. Based on this, a new method for the determination of puerarin using a flow injection chemiluminescence technique was developed. The experimental parameters that affected the CL intensity were optimized. Under the optimal conditions, the linear range for puerarin concentration was 8.0×10?8?2.0×10?6 mol/L (R=0.9982) with a detection limit of 7.5×10?9 mol/L (S/N=3) and the relative standard deviation was 1.7% for 4.0×10?7 mol/L puerarin (n=11). The proposed method was applied to the determination of puerarin in a puerarin injection with satisfactory results.  相似文献   

2.
《Analytical letters》2012,45(15):2935-2945
Abstract

A novel chemiluminescence (CL) reaction between hydroxyl radical and ascorbic acid is described in this paper. Hydroxyl radical generated on line by the reaction between Fe3+ solution and H2O2 solution in HCl medium could oxidize rhodamine 6G to produce weak chemiluminescence. It was found that ascorbic acid could enhance the chemiluminescence and the excited rhodamine 6G was the emitter of the chemiluminescence reaction. The possible mechanism of the CL system was also discussed. Ascorbic acid can be determined in the range of 2.0×10?6?8.0×10?4 mg/ml with a detection limit of 1×10?6 mg/ml (3σ). A complete analysis could be done in 1 minute with the relative standard deviation of 3.1% for 5.0×10?5 mg/ml (n=11). In order to study the chemiluminescence reaction further, the application to the determination of ascorbic acid in food using the chemiluminescence reaction combined with flow injection is investigated.  相似文献   

3.
《Analytical letters》2012,45(12):2475-2481
Abstract

A new chemiluminescence (CL) reaction was observed when cloperastine hydrochloride was injected into the reaction mixture after the CL reaction of Ce(IV) and sodium sulfite finished. A new flow injection CL method for the determination of cloperastine hydrochloride was established based on the CL reaction. The relative standard deviation (RSD) for the determination of cloperastine hydrochloride was 1.3% (n=11, c=1.0×10?6 g/mL). The CL intensity responded linearly to the concentration of cloperastine hydrochloride in the range 2.0×10?7~2.0×10?5 g/mL (r=0.9962). The detection limit was 5×10?8 g/mL cloperastine hydrochloride. The method had been applied to the determination of cloperastine hydrochloride in tablets with satisfactory results.  相似文献   

4.
A novel flow injection chemiluminescence (FI‐CL) method for the determination of genistein was described. The method was based on the reaction between genistein and potassium ferricyanide in alkaline solution to give weak CL signal, which was dramatically enhanced by rhodamine 6G (Rh G). The CL emission allowed quantitation of genistein concentration in the range 1.0 × 10?7–4.0 × 10?5 mol/L with a detection limit (3σ) of 4.2 × 10?8 mol/L. The relative standard deviation for 11 parallel measurements of 5.0 × 10?7 mol/L, 4.0 × 10?6 mol/L and 1.0 × 10?5 mol/L genistein were 2.59%, 2.40% and 1.48%, respectively. The experimental conditions for the CL reaction were optimized and the possible reaction mechanism was discussed. The method was applied to the determination of genistein in biological fluids.  相似文献   

5.
《Analytical letters》2012,45(6):1033-1045
The amoxicillin-imprinted polymer was synthesized with methacrylic acid (MAA) as a functional monomer and ethylene glycol dimethacrylate (EGDMA) as a cross-linker. The binding characteristic of the imprinted polymer to amoxicillin was evaluated by equilibrium binding experiments. Using the imprinted polymer as recognition material, 3-(3′-nitrophenyl)-5(2′-sulfonylphenylazo)-rhodanine (4NRASP) was synthesized by the authors and was used as chemiluminescence (CL) reagent. A novel chemiluminescence (CL) sensor for the determination of amoxicillin was developed based on the CL reaction of amoxicillin with potassium permanganate in an acidic medium. The sensor displayed excellent selectivity and high sensitivity. The linear response range of the sensor was from 5.0 × 10?9 to 1.0 × 10?6 g · mL?1 (r = 0.9985) and the detection limit was 1.3 × 10?9 g · mL?1. The relative standard deviation for the determination of 1.0 × 10?7 g · mL?1 amoxicillin solution was 1.7% (n = 11). The sensor was applied to the determination of amoxicillin in urine samples with satisfactory results.  相似文献   

6.
Based on the micelle synergism mechanism, a chemiluminescence (CL) flow system for the determination of sulfite was described. The CL signal generated from the reaction of chlorate with sulfite in acidic solution was very weak, while the interfusion of sodium dodecylbenzenesulfonate (SDBS) resulted in a highly chemiluminescent intensity. The major goal of this work was to investigate and develop the SDBS rnicelle synergetic CL system. The mechanism was proposed and proved by spectrometry. The results indicated that the unique structure of SDBS micelles prorooted the aggregation of rhodamine 6G (Rh6G) and a much easier energy transfer, leading to a marked shift to red in the CL emission. This CL system was developed for the determination of sulfite and the concentration of sulfite was proportional to the CL intensity in the range of 5.0× 10^-8--1.0× 10^-5 mol/L with the detection limit of 1.7×10^-8 mol/L (S/N=3). The relative standard deviation was 3.3% for 1.0×10^ 6 mol/L sulfite solution with eleven repeated measurements. This method was successfully applied to the determination of sulfite in powder sugar.  相似文献   

7.
《Analytical letters》2012,45(16):3148-3157
Abstract

A simple, rapid, and automated assay for hydrogen peroxide in pharmaceutical samples was developed by combining the multicommutation system with a chemiluminescence (CL) detector. The detection was performed using a spiral flow‐cell reactor made from polyethylene tubing that was positioned in front of a photodiode. It allows the rapid mixing of CL reagent and analyte and simultaneous detection of the emitted light. The chemiluminescence was based on the reaction of luminol with hydrogen peroxide catalyzed by hexacyanoferrate(III).

The feasibility of the flow system was ascertained by analyzing a set of pharmaceutical samples. A linear response within the range of 2.2–210 µmol l?1 H2O2 with a LD of 1.8 µmol l?1 H2O2 and coefficient of variations smaller than 0.8% for 1.0×10?5 mol l?1 and 6.8×10?5 mol l?1 hydrogen peroxide solutions (n=10) were obtained. Reagents consumption of 90 µg of luminol and 0.7 mg of hexacyanoferrate(III) per determination and sampling rate of 200 samples per hour were also achieved.  相似文献   

8.
A method is described for determination of fenbufen that is based on the chemiluminescence (CL) reaction of the ${\text{Ru}}\left( {{\text{phen}}} \right)_3^{2 + } $ –cerium(IV)–fenbufen system. An enhanced CL reaction was developed, and optimum conditions for CL were investigated. The CL was linearly dependent on fenbufen concentration in the range 4.0?×?10?8–9.0?×?10?6 mol L?1. The detection limit was 2.0?×?10?8 mol L?1. The relative standard deviation (RSD) was 2.8% for eleven measurements of 6.0?×?10?7 mol L?1 fenbufen standard solution. The new method enables simple, sensitive, and rapid determination of fenbufen and has been used for determination of fenbufen in pharmaceutical preparations in capsule, spiked serum and urine samples.  相似文献   

9.
《Analytical letters》2012,45(1-3):38-47
A new flow injection chemiluminescence method for the determination of phenol was proposed, based upon the chemiluminescence reaction of phenol, N-bromosuccinimide, and hydrogen peroxide in neutral aqueous medium in the presence of cetyltrimethylammonium bromide surfactant micelles. The chemiluminescence signal was proportional to the concentration of phenol in the range of 1.0 × 10?7?8.0 × 10?6 g/mL with a detection limit of 3 × 10?8 g/mL. The relative standard deviation for 1.0 × 10?6 g/mL phenol solution was 2.0% (n = 11). The proposed method was successfully applied to the determination of phenol in phenol ear drops. A possible CL reaction mechanism was also discussed briefly.  相似文献   

10.
《Analytical letters》2012,45(14):2234-2245
A novel chemiluminescence (CL) method is developed for determination of ofloxacin and levofloxacin with Ag(III) complex in H2SO4 solution medium. The CL intensity is proportional to drug concentration in a wider range with a correlation coefficient of 0.999. The limit of detection (s/n = 3) for ofloxacin and levofloxacin was 5.3 × 10?9 g ml?1 and 8.3 × 10?9 g ml?1, respectively, and their recoveries from urine and serum samples were in the range of 90.1–112% with the RSDs of 1.0–2.8%. The proposed method was applied for analysis of real samples with satisfactory result. The possible CL mechanism was discussed.  相似文献   

11.
Fang Zhao 《Analytical letters》2013,46(11):1793-1803
A flow injection post chemiluminescence (FI-PCL) reaction was found when astemizole was mixed with the CL reaction mixture of N-bromosuccinimide and calcein under alkaline conditions. Based on this observation, a simple and sensitive post chemiluminescence (PCL) technique for the assay of astemizole was described. Under the optimized conditions, the PCL values responded linearly to the concentration of astemizole in the range 1.0 × 10?3–3.0 µg/mL, with a detection limit of 7.0 × 10?4 µg/mL. The relative standard deviation was 1.7% for 1.0 × 10?2 µg/mL astemizole solution (n = 13). It was applied to the determination of astemizole in pharmaceutical preparations with satisfactory results.  相似文献   

12.
Jiangman Liu 《Analytical letters》2013,46(11):1804-1815
A sensitive method for the determination of total chromium in real samples by flow injection–chemiluminescence (FI–CL) analysis was proposed. It was found that the CL intensity from luminol–lysozyme reaction could be markedly quenched, and the decrease of CL intensity was linear with the logarithm of Cr(III) concentrations over the range of 5.0 to 4000 pg mL?1 with a detection limit of 2.0 pg mL?1 (3σ) and relative standard deviations (RSDs) of 3.0, 2.6, and 2.0% for 10, 100, and 1000 pg mL?1 Cr(III) (n = 7), respectively. At a flow rate of 2.0 mL min?1, the whole process including sampling and washing could be accomplished within 36 s. The proposed CL method was successfully applied to the determination of total chromium in pharmaceutical capsules, a dietary supplement, and spiked human serum samples, with recoveries from 92.2 to 108.4% and RSDs of less than 4.0%. Using the homemade FI–CL model, the binding constant (K = 4.38 × 106 L mol?1) and the binding sites (n ≈ 1) of Cr(III) to lysozyme were given.  相似文献   

13.
 A rapid flow-injection method with chemiluminescence (CL) detection is described for the determination of glutathione (GSH). The method is based on the CL reaction of luminol and hydrogen peroxide. GSH can greatly enhance the chemiluminescence intensity in 0.1 mol/L borax–sodium hydroxide buffer solution (pH = 9.7). The maximum CL intensity was directly proportional to the concentration of GSH in the range 3.0 × 10−7–2.0 × 10−5 mol/L, and the detection limit was 6.8 × 10−8 mol/L. The relative standard deviation was 3.4% for 5.0 × 10−6 mol/L of GSH (n = 11). Received October 23, 2001; accepted June 18, 2002  相似文献   

14.
《Analytical letters》2012,45(18):3405-3416
Abstract

A post‐chemiluminescence (PCL) was observed when loperamide hydrochloride solution was injected into the reaction mixture after the finish of CL reaction of alkaline N‐Chlorosuccinimide (NCS) and dichlorofluorescein. Based on this phenomenon, a simple, sensitive and fast flow injection PCL method was established for the determination of loperamide hydrochloride. The possible mechanism for the PCL reaction was discussed via the investigation of the CL kinetic characteristics, the CL spectra, the fluorescence spectra. The PCL intensity responded linearly to the concentration of loperamide hydrochloride in the range 8.0×10?10 to 6.0×10?7 g · ml?1 with a linear correlation of 0.9995. The detection limit was 4×10?10 g · ml?1. The relative standard deviation was 2.4% for 4.0×10?8 g · ml?1 loperamide hydrochloride (n=11). This method has been applied to the determination of loperamide hydrochloride in human plasma and pharmaceutical samples with satisfactory results.  相似文献   

15.
《Analytical letters》2012,45(4):626-636
A new chemiluminescence system of Tb3+/K2S2O8 was developed for the determination of albumin. Some experimental conditions were examined and optimized. The linear ranges of the calibration curves are 5.0 × 10?9–5.0 × 10?6 mol/L for bovine serum albumin, 5.0 × 10?8–1.0 × 10?5 mol/L for human serum albumin and 2.5 × 10?7–1.0 × 10?5 mol/L for ovalbumin, and the corresponding detection limits are 1.9 × 10?9 mol/L, 1.5 × 10?8 mol/L, and 1.5 × 10?7 mol/L, respectively. The method was applied to the determination of albumin in human serum samples, and the results were in agreement with those obtained by the bromcresol green method. The relative errors for the analytical results were from ?2.0% to 4.3%.  相似文献   

16.
《Analytical letters》2012,45(13):2412-2423
Abstract

A rapid and sensitive chemiluminescence method using flow-injection has been developed for the determination of an analgesic agent drug, piroxicam. The method is based on the chemiluminescence reaction of piroxicam with an acidic potassium permanganate and Ru(bipy)3 2+. The chemiluminescence intensity is greatly enhanced when quinine sulfate is used as a sensitizer. After optimization of the different experimental parameters, a calibration graph was obtained over a concentration range of 3.0 × 0?8–3.0 × 0?5 mol L?1 with the detection limit of 1.0 × 0?8 mol L?1. The relative standard deviation is 1.5% (n = 11) for the determination of 8.0 × 10?7 mol L?1 piroxicam. The proposed method was successfully applied to commercial tablets, spiked serum, and urine samples.  相似文献   

17.
《Analytical letters》2012,45(5):746-757
Abstract

Flow injection chemiluminescence (FI-CL) with molecularly imprinted polymer (MIP) was applied to determine fenfluramine. The fenfluramine-imprinted polymer was prepared with acrylamide (AM) as functional monomer and ethylene glycol dimethacrylate (EGDMA) as cross-linker. Methyl and sulfonic group were introduced to rhodanine matrix, and a novel rhodanine ramification 3MORASP was synthesized by the author, and it was used as chemiluminescence reagent. 3-(3′-Methoxyphenyl)-5(2′-sulfonylphenylazo)-rhodanine (3MORASP), first synthesized by the authors, was used as chemiluminescence (CL) reagent. The novel flow path of FI-CL was designed, which made three merged streams of reactants injected into MIP column move through different pathways simultaneously. Fenfluramine was detected based on the reaction of fenfluramine, 3MORASP, and potassium permanganate in an acidic medium. The CL intensity was correlated linearly with the concentration of fenfluramine over the range of 1.0 × 10?7 to 5.0 × 10?6 g · mL?1, and the detection limit was 9.48 × 10?9 g · mL?1. The relative standard deviation (RSD) was 2.4% for determination of 1.0 × 10?6 g · mL?1 fenfluramine (n = 11). This method was successfully applied to the determination of fenfluramine in weight-reducing tonic.  相似文献   

18.
Rifampicin can enhance the chemiluminescence (CL) of peroxomonosulfate‐cobalt(II) system, and the CL intensity is strongly dependent on the rifampicin concentrations. Based on this phenomenon, a rapid and sensitive flow injection CL method was developed for the determination of rifampicin. The relative CL intensity was linear with the rifampicin concentration over the range of 5×10?8 to 1×10?6 g·mL?1 (r=0.9991), the detection limit was 7×10?9 g·mL?1 (S/N=3), and the relative standard deviation was 2.7% for 6×10?7 g·mL?1 rifampicin (n=11). Furthermore, this method was successfully applied to the determination of rifampicin in real eye drop and capsules sample.  相似文献   

19.
《Analytical letters》2012,45(9):1579-1591
Abstract

Salbutamol is a bronchodilator whose use is restricted due to its anabolic effects. A flow-based procedure for salbutamol determination based on the inhibition of chemiluminescence of the luminol/hypochlorite system was developed. A flow cell constructed with a liquid-core waveguide was employed to constrain the emitted radiation, minimizing losses during transport to detector. Linear response was observed within 2.5 × 10?6 and 1.0 × 10?5 mol L?1 with a detection limit estimated as 1 × 10?7 mol L?1 at the 99.7% confidence level. The coefficient of variation (n = 20), sampling rate, and luminol consumption per determination were estimated as 2.8%, 164 determinations h?1, and 50 µg, respectively. Results for pharmaceutical samples were in agreement with those obtained by reference procedures at the 95% confidence level.  相似文献   

20.
《Analytical letters》2012,45(15):3285-3302
ABSTRACT

A sensitive chemiluminescence (CL) induced by light for the determination of riboflavin with flow injection analysis is developed. Riboflavin shows a strong enhancement effect on the CL reaction of luminol oxidized by periodate after the photochemical reaction of riboflavin in alkaline solution, and the enhancing effect of riboflavin disappears under dark conditions. Oxygen can further improve the enhancing effect of the riboflavin in this CL system, and the effects were also investigated. And based on this phenomenon, a very sensitive method of various surfactants, β-cyclodextrin and organic solvents on this CL system for the determination of riboflavin was described. The range of the linear response for riboflavin using this method is ca. 2.4×10?8 ~ 1.0 × 10?6 mol/L, and the detection limit (S/N = 3) is l.0×10?8 mol/L. The applicability of the method was demonstrated by the determination of riboflavin in pharmaceutical preparation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号