首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 781 毫秒
1.
《Analytical letters》2012,45(8):1375-1386
Abstract

A novel chemiluminescence method for the quantitative assay of the organophosphorus pesticide chlorpyrifos in vegetable samples is presented. The determination is based on the reaction of chlorpyrifos with luminol-H2O2 in alkaline medium with sodium chloride being enhancer. Under the optimum conditions, the increased CL intensity was proportional with the concentration of chlorpyrifos in the range of 1.0 × 10?8 g · ml?1 ? 1.0 × 10?6 g · ml?1 and the detection limit was 3.5 × 10?9 g · ml?1 (3σ). The relative standard is less than 3.9% for 5.0 × 10?7g · ml?1 chlorpyrifos (n = 7). This method has been successfully applied to the determination of chlorpyrifos residue in vegetable sample. Further study was focused on the mechanism of chlorpyrifos and the possible mechanism was proposed.  相似文献   

2.
《Analytical letters》2012,45(18):3405-3416
Abstract

A post‐chemiluminescence (PCL) was observed when loperamide hydrochloride solution was injected into the reaction mixture after the finish of CL reaction of alkaline N‐Chlorosuccinimide (NCS) and dichlorofluorescein. Based on this phenomenon, a simple, sensitive and fast flow injection PCL method was established for the determination of loperamide hydrochloride. The possible mechanism for the PCL reaction was discussed via the investigation of the CL kinetic characteristics, the CL spectra, the fluorescence spectra. The PCL intensity responded linearly to the concentration of loperamide hydrochloride in the range 8.0×10?10 to 6.0×10?7 g · ml?1 with a linear correlation of 0.9995. The detection limit was 4×10?10 g · ml?1. The relative standard deviation was 2.4% for 4.0×10?8 g · ml?1 loperamide hydrochloride (n=11). This method has been applied to the determination of loperamide hydrochloride in human plasma and pharmaceutical samples with satisfactory results.  相似文献   

3.
《Analytical letters》2012,45(7):1279-1289
Abstract

Based on the fact that nonionic surfactant polyethylene glycol-400 (PEG-400) catalyzed the chemiluminescence of luminol-H2O2 system, a novel and simple chemiluminescence method has been developed for the determination of PEG-400. Under the optimal conditions, the standard curve was Y = 198835X–2091.8, where the correlation coefficient (R) was 0.9999. The detection limit was 4 × 10?5 g·ml?1 PEG-400 and the linear range was 1.0 × 10?4–4.0 × 10?2g·ml?1. The relative standard deviation was 3.2% at 2.0 × 10?3 g·ml?1 PEG-400 (n = 7). This method has been applied to the determination of PEG-400 in cosmetic samples with satisfactory results. Furthermore, the dynamics characteristic curve of PEG-400 in luminol-H2O2 system was compared to typical metallic ion and other surfactants. Moreover, the mechanism of the luminol-H2O2-PEG-400 chemiluminescence system was studied, assisted by fluorescence spectra and UV spectra.  相似文献   

4.
The possibility of using ionic liquid based chitosan sorbent for the separation and preconcentration of fluoroquinolone antibiotics (marbofloxacin, enoxacin, ofloxacin, ciprofloxacin, and enrofloxacin) has been studied. For this reason, different ionic liquids were prepared and coated on the chitosan sorbent. The conditions of the preconcentration of fluoroquinolones on a microcolumn have been optimized and the extraction efficiencies of the prepared sorbents have been compared. The compounds were eluted with 5 mL of 20% NH3 (v/v, MeOH) solution and determined by HPLC with diode array and fluorescence detector. The limits of detection were found as 4.23 µ g L?1 for marbofloxacin, and 1.09 µg L?1 for enoxacin; 3.23 × 10?3 µg L?1 for ofloxacin; 8.39 × 10?3 µg L?1 for ciprofloxacin; and 19.50 × 10?3 µg L?1 for enrofloxacin. The developed method was applied for the analysis of fluoroquinolone in milk, egg, fish, bovine, and chicken samples and the recoveries were obtained in the range 70–100%.  相似文献   

5.
《Analytical letters》2012,45(5):973-983
Abstract

A rapid and sensitive flow‐injection chemiluminescence (FI‐CL) method, which is based on the CL intensity that generated from the redox reaction of Ce(IV)‐rhodamine B in H2SO4 medium, for the determination of acyclovir and gancyclovir is described. For acyclovir, the determination range is 3×10?8 g mL?1–7×10?5 g mL?1, with 1.56×10?8 g mL?1 as its determination limit. During 11 repeated measurements for 1×10?6 g mL?1 acyclovir, the relative standard deviation was 2.08%. For gancyclovir, the determination range was 5×10?8 g mL?1–7×10?5 g mL?1, with 2.35×10?8 g mL?1 as its determination limit. The relative standard deviation is 2.83% with 11 repeated measurements of 1×10?6 g mL?1 gancyclovir. This method can be successfully used to determine the content of acyclovir and gancyclovir in injections, acyclovir in eye drops, and, maybe, also for other ciclovirs.  相似文献   

6.
A novel flow injection procedure has been developed for the determination of gallic acid based on the enhancement function for luminol‐AgNO3‐Ag NPs chemiluminescence (CL) system by gallic acid. The enhancement mechanism was proposed for the reinforcing effect of the gallic acid on the CL system. The UV‐vis absorption spectrum and CL emission spectrum were applied to confirm the mechanism. The method is simple, rapid and sensitive with a detection limit of 5×10?10 g·mL?1 and a linear range of 8.0×10?10–1.0×10?7 g·mL?1. The relative standard deviation (RSD) is 1.3% for eleven measurements of 5×10?8 g·mL?1 gallic acid. The method has been successfully applied to the determination of gallic acid in Chinese proprietary medicine–Jianmin Yanhou tablets and synthesized samples.  相似文献   

7.
This work presents a new chemiluminescent (CL) probe array assay. The new type CL probe array is based on enzyme mimics of Co3O4–SiO2 mesoporous nanocomposite material, which not only have an excellent catalytic effect on the luminol–H2O2 CL reaction in an alkaline medium but also can be used for the immobilization of enzymes. The linear range of the lactose concentration is 3.0?×?10?7 to 1.0?×?10?5 g mL?1 and the detection limit is 6.9?×?10?8 g mL?1. β-Galactosidase and glucose oxidase were selected as a model for enzyme assays to demonstrate the applicability of Co3O4–SiO2 mesoporous nanocomposite material in multienzyme immobilization. The novel bifunctional CL probe array has been successfully applied to the determination of lactose in milk.  相似文献   

8.
《Analytical letters》2012,45(6):1033-1045
The amoxicillin-imprinted polymer was synthesized with methacrylic acid (MAA) as a functional monomer and ethylene glycol dimethacrylate (EGDMA) as a cross-linker. The binding characteristic of the imprinted polymer to amoxicillin was evaluated by equilibrium binding experiments. Using the imprinted polymer as recognition material, 3-(3′-nitrophenyl)-5(2′-sulfonylphenylazo)-rhodanine (4NRASP) was synthesized by the authors and was used as chemiluminescence (CL) reagent. A novel chemiluminescence (CL) sensor for the determination of amoxicillin was developed based on the CL reaction of amoxicillin with potassium permanganate in an acidic medium. The sensor displayed excellent selectivity and high sensitivity. The linear response range of the sensor was from 5.0 × 10?9 to 1.0 × 10?6 g · mL?1 (r = 0.9985) and the detection limit was 1.3 × 10?9 g · mL?1. The relative standard deviation for the determination of 1.0 × 10?7 g · mL?1 amoxicillin solution was 1.7% (n = 11). The sensor was applied to the determination of amoxicillin in urine samples with satisfactory results.  相似文献   

9.
《Analytical letters》2012,45(18):3417-3429
Abstract

A flow‐injection spectrophotometric procedure was developed for determining N‐acetylcysteine in pharmaceutical formulations. The sample was dissolved in deionized water and 400 µl of the solution was injected into a carrier stream of 1.0×10?2 mol l?1 sodium borate solution. The sample flowed through a column (70 mm length×2.0 mm i.d.) packed with Zn3(PO4)2 immobilized in a polymeric matrix of polyester resin and Zn(II) ions were released from the solid‐phase reactor because of the formation of the Zn(II) (N‐acetylcysteine)2 complex. The mixture merged with a stream of borate buffer solution (pH 9.0) containing 5.0×10?4 mol l?1 Alizarin red S and the Zn(II)Alizarin red complex formed was measured spectrophotometrically at 540 nm. The analytical curve was linear in the N‐acetylcysteine concentration range from 3.0×10?5 to 1.5×10?4 mol l?1 (4.9 to 24.5 µg ml?1) with a detections limit of 8.0×10?6 mol l?1 (1.3 µg ml?1). The relative standard deviations (RSDs) were smaller than 0.5% (n=10) for solutions containing 5.0×10?5 mol l?1 (8.0 µg ml?1) and 8.0×10?5 mol l?1 (13.0 µg ml?1) of N‐acetylcysteine, and the analytical frequency was 60 determinations per hour. A paired t‐test showed that all results obtained for N‐acetylcysteine in commercial formulations using the proposed flow‐injection procedure and a comparative procedure agreed at the 95% confidence level.  相似文献   

10.
《Analytical letters》2012,45(7):989-999
Abstract

A new method for flow-injection analysis (FIA) for the determination of penicillins based on the extraction and spectrophotometric determination of ion associates with selected thiazine dyes (methylene blue, azure A, and azure B) is proposed. The reaction conditions (cdye = 2 × 10?4 mol l?1, cKCl = 1 mol l?1, pH ? 6, λ = 635 nm) were found. The factorial design has been carried out to determine the optimum flow conditions. A wide linear dynamic range of calibration curves (5.1–700 µg ml?1 for penicillin V with all dyes, R = 0.9985) and good repeatability (e.g., relative standard deviation [RSD] = 4.6–0.6% in this concentration range for the reaction with azure B) were found. The detection limit for penicillin V is 1.5 µg ml?1, and the determination limit is 5.1 µg ml?1. The maximum analysis rate is 35 samples per h. The practical samples of pharmaceutics were tested. There are no interferences from the additives in pharmaceutics.  相似文献   

11.
《Analytical letters》2012,45(5):837-852
Abstract

A simple, rapid, sensitive, and reproducible procedure for assaying norfloxacin (NOR), ciprofloxacin (CIP), and ofloxacin (OFL) was investigated. The procedure is based on the reaction of selected drugs with Sudan II (I), Congo red (II), and Gentian violet (III) in universal buffer to give soluble ion‐pair complexes. The effects of various parameters have been studied. Beer's law plots were obeyed in the concentration ranges 0.5–11 µg ml?1, whereas Ringbom optimum ranges were 0.7–9.5 µg ml?1. The apparent molar absorptivity (6.4×104 L mol?1 cm?1), Sandell sensitivity (4.99 ng cm?2), detection (0.13 µg ml?1), and quantification (0.44 µg ml?1) limits were calculated. The relative standard deviation for ten determinations, for samples containing 4.0 µg ml?1, was found to be 1.40%. The influence of commonly employed excipients in the determination of the studied drugs was examined. There was no interference from degradate product results from thermal and hydrolytic treatments. The results obtained by the proposed procedure were statistically validated. The developed procedure was successfully applied to the determination of the studied drugs in dosage forms and biological fluids.  相似文献   

12.
《Analytical letters》2012,45(12):1933-1941
Abstract

A rapid and simple flow‐injection chemiluminescence (CL) method is described for the determination of perphenazine, which is based on the CL intensity that generated from the redox reaction of Ce (IV)-perphenazine in HNO3 medium is proportional to the perphenazine concentration without any sensitizers. The proposed method allows the determination range within 1.0×10?7–7.0 ×10?5 g mL?1 with a detection limit of 8.0×10?8 g mL?1, and it has been successfully applied to the determination of the perphenazine in pharmaceutical tablet compared well with the official method.  相似文献   

13.
《Analytical letters》2012,45(13):2207-2216
Abstract

A simple and selective spectrophotometric method has been developed for the determination of trace amounts of arsenic using azure B as a chromogenic reagent. The proposed method is based on the reaction of arsenic(III) with potassium iodate in acid medium to liberate iodine. The liberated iodine bleaches the violet color of azure B and is measured at 644 nm. This decrease in absorbance is directly proportional to the As(III) concentration, and Beer's law is obeyed in the range 0.2–10 µg ml?1 of As(III). The molar absorptivity, Sandell's sensitivity, detection limit, and quantitation limit of the method were found to be 1.12×104 l mol?1cm?1, 6.71×10?3 µg cm?2, 0.02 µg ml?1 and 0.08 µg ml?1, respectively. The optimum reaction conditions and other analytical parameters were evaluated. The proposed method has been successfully applied for the determination of arsenic in various environmental and biological samples.  相似文献   

14.
A simple, rapid and sensitive method has been proposed for simultaneous electrogenerated-chemiluminescent detection of quinolone residues in biological fluid after effective separation by capillary electrophoresis. Enrofloxacin, levofloxacin and ciprofloxacin can be assayed in the range of 3.0 × 10?8–5.0 × 10?6 g mL?1 within 10 min. The relative standard deviations of the signal intensity and the migration time were less than 4.9 and 2.4% for a standard sample containing 1.0 × 10?7 g mL?1 of each quinolone (= 5), respectively. The presented method has been successfully applied to determine the amounts of quinolones in pig urine after clean-up by C18 solid phase extraction column.  相似文献   

15.
《Analytical letters》2012,45(12):2384-2390
Abstract

A novel spectrophotometric method for the determination of titanium(IV) by using a new reagent, water extract of slippery elm leaf is developed. In 0.05 M hydrochloric acid, titanium(IV) reacts with this reagent to form a yellow product. The formed product shows maximum absorbance at 415 nm with a molar absorptivity value of 0.68×104 l mol–1 cm–1 and the method was linear in the 0.2–6 µg ml?1 concentration range. The detection limit value was found to be 0.0131 µg ml?1. The proposed method was simple, low cost, selective, and sensitive. It was applied to the analytic samples with satisfactory results.  相似文献   

16.
Rifampicin can enhance the chemiluminescence (CL) of peroxomonosulfate‐cobalt(II) system, and the CL intensity is strongly dependent on the rifampicin concentrations. Based on this phenomenon, a rapid and sensitive flow injection CL method was developed for the determination of rifampicin. The relative CL intensity was linear with the rifampicin concentration over the range of 5×10?8 to 1×10?6 g·mL?1 (r=0.9991), the detection limit was 7×10?9 g·mL?1 (S/N=3), and the relative standard deviation was 2.7% for 6×10?7 g·mL?1 rifampicin (n=11). Furthermore, this method was successfully applied to the determination of rifampicin in real eye drop and capsules sample.  相似文献   

17.
《Analytical letters》2012,45(14):2037-2052
A rapid and simple flow injection (FI) method is reported for the determination of vitamin A (retinol) based on its strong enhancing effect on the Ce(IV)–Na2SO3 chemiluminescence (CL) reaction in an acidic solution. The effect of key chemical and physical parameters (i.e., reagent concentrations, flow rate, and sample volume) was optimized and potential interferences examined. Under the selected experimental conditions, a linear calibration was obtained between the CL intensity and vitamin A concentration in the range 0.1–8.0 µg mL?1 (r 2  = 0.9986, n = 8). The limit of detection (3 s x blank) was 0.01 µg mL?1 retinol (n = 6) and the relative standard deviation (RSD) for 0.25 µg mL?1 retinol was 2.3% (n = 10) with a sampling rate of 180 h?1. The method was successfully applied to infant milk-based formulas and pharmaceutical formulations and the results were not significantly different at 95% confidence interval with those obtained by using a spectrophotometric reference method. The possible CL mechanism is also discussed briefly supporting with UV-visible, fluorescence, and CL spectra.  相似文献   

18.
A simple, rapid and accurate high performance liquid chromatographic (HPLC) technique coupled with chemiluminescence (CL) detection was developed for the simultaneous determination of epinephrine (E), noradrenaline (NA) and dopamine (DA). It was based on the analyte enhancement effect on the CL reaction between luminol and potassium ferricyanide. The effects of various parameters, such as potassium ferricyanide concentration, luminol concentration, pH value and component of the mobile phase on chromatographic behaviors of the analytes (E, NA and DA) were investigated. The separation was carded out on C18 column using the mobile phase of 0.01 mol/L potassium hydrogen phthalate solution and methanol (92 : 8, V/V). Under the optimum condi- tions, E, NA and DA showed good linear relationships in the range of 1 × 10^-8 -5 × 10^-6, 5.0× 10^-9 -1.0× 10^-6 and 5.0×10^-9-1.0× 10^-6 g]mL respectively. The detection limits for E, NA and DA were 4.0×10^-9, 1.0× 10^-9 and 8.0 × 10^-10 g/mL. The proposed method has been applied successfully to the analysis of E, NA and DA in human serum samples.  相似文献   

19.
《Analytical letters》2012,45(14):2026-2036
A novel chemiluminescence (CL) system was established for the determination of diammonium glycyrrhizinate (DG) in pharmaceutical preparations and its ability of scavenging hydroxyl radical. It was shown that a strong CL signal was observed when Eosin Y mixed with Fenton reagent. The CL intensity was decreased significantly when DG was added to the reaction system and partially scavenged the hydroxyl radicals in the solution. The extent of decrease in the CL intensity had a good stoichiometrical relationship with DG concentration. Based on this, we developed a new method for the determination of DG using a flow injection chemiluminescence (FI-CL) technique. Under the optimal conditions, the linear range of DG concentration was 6.0 × 10?8–5.0 × 10?6 mol/L (R = 0.9982) with a detection limit of 8.0 × 10?9 mol/L (SN = 3), and the RSD was 3.8% for 2.0 × 10?7 mol/L DG (n = 11). This method was successfully used in the determination of DG in tablets and the evaluation of hydroxyl radical scavenging capacity of DG. The possible reaction mechanism of the CL system is discussed.  相似文献   

20.
In the present work, a novel flow-injection chemiluminescence method based on CdTe quantum dots (QDs) was developed for the determination of nitrite. Weak chemiluminescence (CL) signals were observed from a CdTe QDs–H2O2 system under basic conditions. The addition of a trace amount of hemoglobin (Hb) caused the CL from the CdTe QDs–H2O2 system to increase substantially. In the presence of nitrite, the ferrous Hb reacted with the nitrate to form ferric Hb and NO. The NO then bound to ferrous Hb to generate iron nitrosyl Hb. As a result, the CL signal from the CdTe QDs–H2O2–Hb system was quenched. Thus, a flow-injection CL analytical system for the determination of trace nitrite was established. Under optimum conditions, there was a good linear relationship between CL intensity and the concentration of nitrite in the range 1.0?×?10?9 to 8.0?×?10?7 mol L?1 (R 2?=?0.9957). The limit of detection for nitrite using this system was 3.0?×?10?10 mol L?1 (S/N?=?3). This method was successfully applied to detect nitrite in water samples.
Figure
The scheme of the mechanism of the CL system  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号