首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
《Analytical letters》2012,45(14):2883-2899
ABSTRACT|The catalytic activity of various mimetic enzymes instead of the peroxidase have been investigated by 4-aminoantipyrine (4-AAP) and 2, 3, 4-trichlorophenol (TCP) to form a dye utilizing hydrogen peroxide as hydrogen acceptor. The different Chlorophenolic derivatives, which act as a substrate in β-CD-hemin-H2O2-4-AAP catalytic reaction, have been systematically studied.|Meanwhile, the relationship of structure-effect for the β-CD-hemin as catalyst, and chlorphenols as substrate has been respectively discussed. The mechanism of catalytic reaction has been investigated. The results showed that β-CD-hemin was the best mimetic enzyme for peroxidase among those tested and TCP was a good substrate for the determination of hydrogen peroxide with β-CD-hemin. The method for the determination of hydrogen peroxide was proposed using 4-AAP-TCP system with β-CD-hemin as catalyst. A linear calibration graph was obtained over the H2O2 concentration of 4.8×10-?8-7.7×10-?5M, and the relative standard deviation at a H2O2 concentration of 2.8×10-?5M was 2.5%. The apparent molar absorptivity of the chromogenic reaction for H2O2 was 1.54× 104 L.mol-?1.cm?1. Satisfactory results were obtained in the determination of H2O2 in synthetic samples by this method.

Also, the method was coupled with the glucose oxidation reaction to determination glucose in human serum.  相似文献   

2.
《Analytical letters》2012,45(9):2051-2058
Abstract

The present paper reports a new chemiluminescence system, i.e, acetone-H2O2?C10?, which can be catalyzed by iodide ion (I?). Based on this catalysis, a new chemiluminescence method for the determination of trace iodide ion is proposed. the optimum conditions are reported in this note. the detection limit is 2 × 10?11 g/ml I?, the linear dynamic range is 4 × 10?10 g/ml to 3 × 10?7 g/ml I?, and the variation coefficient at an iodide concentration of 5 × 10?9 g/ml I? (n=10) is 4.6%. the method has been satisfactorily applied to the determination of trace iodide ion in water.  相似文献   

3.
Summary.  A new selective, sensitive, and simple kinetic method is developed for the determination of trace amounts of iodide. The method is based on the catalytic effect of iodide on the reaction of triflupromazine (TFP) with H2O2. The reaction is followed spectrophotometrically by tracing the oxidation product at 498 nm within 1 min after addition of H2O2. The optimum reaction conditions are TFP (0.4 × 10−3 M), H2SO4 (1.0M), H3PO4 (2.0M), and H2O2 (1.6M) at 30°C. Following this procedure, iodide can be determined with a linear calibration graph up to 4.5 ng ċ cm−3 and a detection limit of 0.04 ng ċ cm−3, based on the 3 Sb criterion. The method can also be applied to the determination of iodate and periodate ions. Determination of as little as 0.2, 1.0, 2.0, and 4.0 ng ċ cm−3 of I, IO3 -, or IO4 - in aqueous solutions gave an average recovery of 98% with relative standard deviations below 1.6% (n = 5). The method was applied to the determination of iodide in Nile river water and ground waters as well as in various food samples after alkaline ashing treatment. The method is compared with other catalytic spectrophotometric procedures for iodide determination. Received January 19, 2001. Accepted (revised) March 12, 2001  相似文献   

4.
 A new selective, sensitive, and simple kinetic method is developed for the determination of trace amounts of iodide. The method is based on the catalytic effect of iodide on the reaction of triflupromazine (TFP) with H2O2. The reaction is followed spectrophotometrically by tracing the oxidation product at 498 nm within 1 min after addition of H2O2. The optimum reaction conditions are TFP (0.4 × 10−3 M), H2SO4 (1.0M), H3PO4 (2.0M), and H2O2 (1.6M) at 30°C. Following this procedure, iodide can be determined with a linear calibration graph up to 4.5 ng ċ cm−3 and a detection limit of 0.04 ng ċ cm−3, based on the 3 Sb criterion. The method can also be applied to the determination of iodate and periodate ions. Determination of as little as 0.2, 1.0, 2.0, and 4.0 ng ċ cm−3 of I, IO3 -, or IO4 - in aqueous solutions gave an average recovery of 98% with relative standard deviations below 1.6% (n = 5). The method was applied to the determination of iodide in Nile river water and ground waters as well as in various food samples after alkaline ashing treatment. The method is compared with other catalytic spectrophotometric procedures for iodide determination.  相似文献   

5.
《Analytical letters》2012,45(15):2935-2945
Abstract

A novel chemiluminescence (CL) reaction between hydroxyl radical and ascorbic acid is described in this paper. Hydroxyl radical generated on line by the reaction between Fe3+ solution and H2O2 solution in HCl medium could oxidize rhodamine 6G to produce weak chemiluminescence. It was found that ascorbic acid could enhance the chemiluminescence and the excited rhodamine 6G was the emitter of the chemiluminescence reaction. The possible mechanism of the CL system was also discussed. Ascorbic acid can be determined in the range of 2.0×10?6?8.0×10?4 mg/ml with a detection limit of 1×10?6 mg/ml (3σ). A complete analysis could be done in 1 minute with the relative standard deviation of 3.1% for 5.0×10?5 mg/ml (n=11). In order to study the chemiluminescence reaction further, the application to the determination of ascorbic acid in food using the chemiluminescence reaction combined with flow injection is investigated.  相似文献   

6.
Thermal lens spectrometry was used for the differential kinetic determination of aniline (over the concentration range of 8 × 10−4–3.2 × 10−3 M) and 4-nitroaniline (2 × 10−4–1.6 × 10−3 M) present in combination in a single sample based on the oxidation reaction with periodate ions in an acidic medium (this determination is not possible with the spectrophotometric monitoring of the rate of reaction). The thermal lens procedure (λe = 488.0 nm; 80 mW) was characterized by good performance characteristics in the determination of aniline (c min = 3 × 10−4 M; c d = 8 × 10−4 M) and 4-nitroaniline (c min = 7 × 10−5 M; c d = 2 × 10−4 M), simplicity, and rapidity.  相似文献   

7.
《Analytical letters》2012,45(15):2743-2753
Abstract

The electrochemical behavior of 6-MP was studied by cyclic voltammetry at a hanging copper amalgam dropping electrode (HCADE). It was found that 6-MP could form a complex with the Cu(II) stripped from the HCADE, showing a new peak at ?0.19V in the medium of 0.1mol/L LiClO4-0.5mol/L HClO4 solution. The mechanism of the reaction was proposed. This new peak was sensitive and could be used for the determination of trace 6-MP by differential pulse adsorption cathodic stripping voltammetry (DPAdCSV). The linear range was from 3.6×10?10 to 5.3×10?6 mol/L, and the detection limit was about 1.2×10?10 mol/L (S/N=3). The method was also successfully applied to the determination of 6-MP in pharmaceutical tablets.  相似文献   

8.
The catalytic oxidation of 1-amino-2-naphthol-4-sulfonic, acid proceeds quickly with microgram amounts of iodide in the presence of sodium chlorate at pH between 1.3 and 2.0. The oxidation product shows a sensitive tensammetric wave at potentials of about +0.03 V vs. SCE (pH 1.75), so that the catalytic reaction was applied for the determination of microgram amounts of iodide ion. The most suitable conditions of the pH range, the concentration of ANS and sodium chlorate, reaction temperature and standing are 1.3–2.0, 3 × 10?4M, 0.05 M, 50° C and 1 h respectively. Using the recommended procedure, iodide ion can be determined precisely in the concentration range 0.4–6.5 ng ml?1 with a relative error of about 3%. Interference of foreign species and the application to the determination of total iodine in river and sea water are described.  相似文献   

9.
《Analytical letters》2012,45(3-4):283-293
Abstract

A spectrofluorimetric procedure for the determination of micromolar concentrations of antimony(III) was devised based on its reduction of cerium(IV) to produce fluorescent cerium(III). The method was optimized and the reaction was fast enough in hydrochloric acid media without the need for iodide or osmium(VIII) as catalysts. Linear calibration graphs were obtained in the range 1-10 10?6M. The standard deviation for determining 5 × 10?6M antimony(III)(10 times) was 1.43 × 10?7M and the relative error was -3.4 %. The method was applied to the determination of antimony(III) in its mixture with antimony(V), total antimony was later determined after reduction with mercury metal in deoxygenated solutions. The affect several reducing agents on the determination of antimony-was also examined.  相似文献   

10.
A new simple, rapid and sensitive spectrophotometric flow injection method for the determination of trace iodide is described based on an ion associate of iodate (IO3 ) with 2- (3,5-dibromo-2-pyridylazo)-5-diethylamino-phenol (3,5-Br2-PADAP) and thiocyanate (SCN). In a strongly acidic medium, this unstable violet product was formed with an absorption maximum at 605 nm. Flow injection is an ideal method to reproducibly monitor the transient signal. Various parameters were optimized using the Super Modified Controlled Weighted Centroid Simplex Method (SMCWC). Under the optimum experimental conditions, iodide could be determined in the range of 1.00 × 10–6 and 2.4 × 10–5 mol l–1. The correlation coefficient of the calibration curve is 0.9991. With a sampling frequency of 80 h–1, the detection limit for iodide is 5.0 × 10–7 mol l–1. The proposed method has been applied to the determination of trace iodide after oxidizing I in table salt or laver to IO3 . In addition, the mechanisms of the ion association reaction was studied. Received: 15 August 1996 / Revised: 10 October 1996 / Accepted: 16 October 1996  相似文献   

11.
《Analytical letters》2012,45(16):3060-3069
Abstract

Hemin, iron (III) protoporphyrin IX chloride, in NH3‐NH4Cl buffer solution of pH 9.5 produces an insensitive reduction wave at about ?0.70 V (vs. saturated calomel reference electrode, SCE) by using single sweep polarography. Adding oxidant K2S2O8 to the solution, hemin reduction wave is catalyzed, yielding a parallel catalytic wave. The catalytic current is 20 times of hemin original reduction current. The derivative peak height is linearly proportional to the hemin concentration in the range of 7.5×10?8 to 4.5×10?6 mol/l, the detection limit is 5.0×10?8 mol/l. Serum albumin, common amino acids, and metal ions have no interference with the hemin determination. The proposed method has been applied to the determination of hemin content in oral liquid samples with satisfactory results. The parallel catalytic wave is attributed to the catalytic reduction of porphyrin ring of hemin at the dropping mercury electrode. The new method could be useful in biochemical, clinical, and pharmaceutical analysis.  相似文献   

12.
《Analytical letters》2012,45(8):1375-1386
Abstract

A novel chemiluminescence method for the quantitative assay of the organophosphorus pesticide chlorpyrifos in vegetable samples is presented. The determination is based on the reaction of chlorpyrifos with luminol-H2O2 in alkaline medium with sodium chloride being enhancer. Under the optimum conditions, the increased CL intensity was proportional with the concentration of chlorpyrifos in the range of 1.0 × 10?8 g · ml?1 ? 1.0 × 10?6 g · ml?1 and the detection limit was 3.5 × 10?9 g · ml?1 (3σ). The relative standard is less than 3.9% for 5.0 × 10?7g · ml?1 chlorpyrifos (n = 7). This method has been successfully applied to the determination of chlorpyrifos residue in vegetable sample. Further study was focused on the mechanism of chlorpyrifos and the possible mechanism was proposed.  相似文献   

13.
《Electroanalysis》2004,16(10):860-865
The electrocatalytic oxidation of sulfite has been studied on the cobalt pentacyanonitrosylferrate modified glassy carbon electrode (CoPCNF). The CoPCNF films on the glassy carbon electrodes show an excellent electrocatalytic activity toward the oxidation of sulfite in 0.5 M KNO3. The kinetics of the catalytic reaction was investigated by using cyclic voltammetry, rotating disk electrode (RDE) voltammetry and chronoamperometry. The average value of the rate constant, K, for the catalytic reaction and the diffusion coefficient, D, were evaluated by different approaches for sulfite and found to be 2.9×102 M?1s?1 and 4.6×10?6 cm2s?1, respectively. At a fixed potential under hydrodynamic conditions (stirred solutions), the oxidation current is proportional to the sulfite concentration and the calibration plot was linear over the concentration range 5×10?6–1×10?4 M. The detection limit of the method is 3×10?6 M., low enough for the trace sulfite determination.  相似文献   

14.
《Analytical letters》2012,45(15):2763-2774
Abstract

The oxidation of iodide to iodine by nitrous acid in aqueous acidic medium takes place catalytically in the presence of dissolved oxygen and can be followed spectrophotometrically at 288 and 352 nm. An indirect molar absorptivity for nitrite on the basis of I3 ? formation can be as high as 8.5×105 L mol?1 cm?1 at 288 nm. Analytical curves were established. The iodine released in the catalytic cycle can also be titrated with thiosulfate. The reaction is pseudo–second‐order in oxygen consumed, with t1/2=15.7 min at 25°C. A rate determining step could be the NO · O2 as the activated species. Measurements of the iodine formed at catalytic conditions was used to determine nitrite in meat extracts and NOx in car exhausts.  相似文献   

15.
《Analytical letters》2012,45(5):973-983
Abstract

A rapid and sensitive flow‐injection chemiluminescence (FI‐CL) method, which is based on the CL intensity that generated from the redox reaction of Ce(IV)‐rhodamine B in H2SO4 medium, for the determination of acyclovir and gancyclovir is described. For acyclovir, the determination range is 3×10?8 g mL?1–7×10?5 g mL?1, with 1.56×10?8 g mL?1 as its determination limit. During 11 repeated measurements for 1×10?6 g mL?1 acyclovir, the relative standard deviation was 2.08%. For gancyclovir, the determination range was 5×10?8 g mL?1–7×10?5 g mL?1, with 2.35×10?8 g mL?1 as its determination limit. The relative standard deviation is 2.83% with 11 repeated measurements of 1×10?6 g mL?1 gancyclovir. This method can be successfully used to determine the content of acyclovir and gancyclovir in injections, acyclovir in eye drops, and, maybe, also for other ciclovirs.  相似文献   

16.
范顺利  屈芳  林金明 《化学学报》2006,64(18):1876-1880
在碱性介质中, CO32-对H2O2氧化鲁米诺化学发光反应具有重要作用, 荧光素钠对该反应具有很强的增敏作用. 据此, 建立了化学发光法测定二氧化碳的新方法. 方法的线性范围为1.0×10-10~5.0×10-6 mol•L-1 CO32-, 检出限为 1.2×10-11 mol•L-1 CO32- (相当于5.3×10-10 g•L-1 CO2). 该方法用于室内外空气中二氧化碳含量的测定, 相对标准偏差1.8%~2.1% (n=11), 加标实验回收率97.6%~101.4%. 论文还探讨了反应的发光机理, 发光反应很可能是由溶液中的CO32-与H2O2作用而产生的活性自由基引发, 荧光素钠对发光的增敏作用为化学能量转移过程.  相似文献   

17.
《Analytical letters》2012,45(8):1366-1374
Abstract

Chemiluminescence reaction of the system containing europium(III) ion, KMnO4, Na2SO3, and ibuprofen was investigated for the determination of ibuprofen. The introduction of Eu(III) ion into the system of KMnO4-Na2SO3-ibuprofen caused a significant increase in the chemiluminescence signal. The increment of the chemiluminescence signal is proportional to ibuprofen concentration in the range of 5.0 × 10?8–5.0 × 10?6 g/ml with a detection limit of 1 × 10?8 g/ml. The relative standard deviation for 1.0 × 10?7 g/ml ibuprofen solution was 1.7% (n = 11). The proposed method was successfully applied to determine ibuprofen in tablets and human plasma.  相似文献   

18.
《Analytical letters》2012,45(17):3195-3207
Abstract

The use of square‐wave voltammetry in conjunction with a cathodically pretreated boron‐doped diamond electrode for the analytical determination of aspartame in dietary products is described. In this determination, the samples were analyzed without previous treatment in a 0.5 mol l?1 H2SO4 solution. A single oxidation peak at a potential of 1.6 V vs. Ag/AgCl (3.0 mol l?1 KCl) with the characteristics of an irreversible reaction was obtained. The analytical curve was linear in the aspartame concentration range 9.9×10?6 to 5.2×10?5 mol l?1 with a detection limit of 2.3×10?7 mol l?1. The relative standard deviation (n=5) obtained was smaller than 0.2% for the 1.0×10?4 mol l?1 aspartame solution. The proposed method was applied with success to the determination of aspartame in several dietary products and the results were similar to those obtained using an HPLC method at 95% confidence level.  相似文献   

19.
《Analytical letters》2012,45(14):3037-3050
ABSTRACT

A simple and very sensitive method for the determination of formaldehyde is described. Formaldehyde reacts with phloroglucinol in acid medium producing a yellow dye with λmax at 435nm. The method is useful for the determination of formaldehyde in the range 0-2.5μg in an overall volume of 10mL with molar absorptivity of 8.3 × 1041 mol?1 cm?1 and a relative standard deviation of 2% at 1.5μg level (n=10).  相似文献   

20.
A simple and sensitive spectrophotometric method for the determination of L-ascorbic acid with leuco crystal violet is proposed. The determination is based on the oxidation of analyte by potassium iodate. The colourless oxidation products were formed in the quantity equivalent to iodide ions. The iodide ions react with the excess of iodate ions in acidic medium, to form free iodine which oxidized leuco crystal violet (LCV) to the liberated crystal violet (CV +) dye, showing maximum absorption at 588 nm. The absorbance was measured at pH of 4.1–4.2 in 1 cm cuvettes. Beer’s law was obeyed in the concentration range 0.5–4.0 μg/mL. The molar absorptivity of the coloured compound is 4.14 × 104 L/mol cm for L-ascorbic acid. The analytical parameters were optimized and the method was successfully applied to the determination of L-ascorbic acid in pharmaceuticals. The results were compared with those obtained by methods proposed in Polish Standard.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号