首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Levamisole is the most common adulterant found in cocaine samples and its electrochemical determination in cocaine seized samples is a challenge due to peak overlapping with cocaine. Herein, we propose a deconvolution procedure for levamisole determination in seized cocaine samples using screen‐printed carbon electrodes (SPE). Square‐wave voltammetry in 0.04 mol L?1 Britton Robinson buffered solution (pH 8.0) was selected in combination with optimized SWV parameters (f=8 s?1, a=10 mV and ΔEs=1 mV) to result in the best peak resolution to apply the deconvolution procedure. Deconvoluted responses of levamisole in the presence of cocaine were similar to untreated signals of standard levamisole solutions in absence of cocaine. A linear response was obtained in the range of 20–100 μmol L?1 (r=0.995). The results obtained for the analysis of a seized cocaine sample was statistically similar to that obtained by gas chromatography. Other adulterants found in cocaine street samples (paracetamol, glucose, phenacetin, caffeine, boric acid and lidocaine) did not affect the treated of voltammetric responses of levamisole. A pharmaceutical sample containing levamisole was also analyzed on SPEs and a recovery of 93±2 % was obtained (no deconvolution required for this sample), showing great applicability of SPEs for forensic and pharmaceutical analyses.  相似文献   

2.
Cyclic voltammetry was used to investigate the electrochemical behaviour of ascorbic acid at a carbon—epoxy composite electrode modified with the electron mediator cobalt phthalocyanine. The modified electrode reduced the overpotential necessary for the oxidation of the vitamin by approximately 150 mV to 0.21 V vs. The saturated calomel electrode; the process was dependent on the pH of the supporting electrolyte, but independent of ionic strength over the range studied. The relative standard deviation (r.s.d.) of the peak heights of the cyclic voltammograms was 0.81% for a 1 × 10?4 M ascorbic acid solution (n = 7). The optimum supporting electrolyte was found to be 0.05 M phosphate buffer (pH 5).Amperometry in stirred solutions was then done at an applied potential of +0.25 V. The limit of detection was 0.65 ng ml?1 and the calibration graph was linear in the range 175 ng ml?1?50 μg ml?1. The method was used to determine ascorbic acid concentrations in single- and multivitamin preparations; the recovery was 97.86% for the vitamin added to one preparation. The r.s.d. for the analyses in these samples was about 5%. For comparison, the vitamin was also determined in these tablets using LC with UV detection at 254 nm; the correlation coefficient for the levels determined was 0.9989 (p = 0.0007).  相似文献   

3.
Ascorbic acid may be determined spectrophotometrically at 360 nm based on reduction of vanadotungstophosphoric acid using flow-injection analysis. The carrier stream was distilled water and the reagent streams were buffer solution (pH 3.0), 1.735 × 10?3 M dodecatungstophosphoric acid and 1.735 × 10?3 M sodium vanadate. The injection rate was 80 h?1. The calibration graph was linear up to 80 μg ml?1 ascorbic acid and the relative standard deviation for the determination of 20 μg ml?1 ascorbic acid was 1.5% (n=10). The detection limit was 1.0 μg ml?1 ascorbic acid, based on an injection volume of 250 μl. The system was applied to the determination of ascorbic acid in vitamin C tablets.  相似文献   

4.
《Electroanalysis》2004,16(11):949-954
The preparation and the electrochemical study of Disperse Blue 1‐chemically modified electrodes (DB1‐CME), as well as their efficiency for the electrocatalytic oxidation of NADH is described. The proposed mediator was immobilized by physical adsorption onto graphite electrodes. The electrochemical behavior of DB1‐CME was studied with cyclic voltammetry. The electrochemical redox reaction of DB1 was found to be reversible, revealing two well‐shaped pair of peaks with formal potentials 152 and ?42 mV, respectively, (vs. Ag/AgCl/3M KCl) at pH 6.5. The current Ip has a linear relationship with the scan rate up to 800 mV s?1, which is indicative for a fast electron transfer kinetics. The dissociation constants of the immobilized DB1 redox couple were calculated pK1=4 and pK2=5. The electrochemical rate constants of the immobilized DB1 were calculated k1°=18 s?1 and k2°=23 s?1 (Γ=2.36 nmol cm?2). The modified electrodes were mounted in a flow injection manifold, poised at +150 mV (vs. Ag/AgCl/3M KCl) and a catalytic current due to the oxidation of NADH was measured. The reproducibility was 1.4% RSD (n=11 for 30 μM NADH) The behavior of the sensor towards different reducing compounds was investigated. The sensor exhibited good operational and storage stability.  相似文献   

5.
A new analytical methodology for the electrochemical detection of the herbicide maleic hydrazide (3,6‐dihydroxypyridazine) by flow injection analysis is presented. This method is supported by the novel application of a palladium‐dispersed carbon paste electrode as an amperometric sensor for this herbicide. Maleic hydrazide shows anodic electrochemical activity on carbon‐based electrodes (glassy carbon or carbon paste electrodes) in all the pH range. This electrochemical activity is enhanced using metal‐dispersed carbon paste electrodes, especially at Pd‐dispersed CPE which displays good oxidation signals at 690 mV (0.050 M phosphate buffer pH 7.0), 140 mV lower than at unmodified electrodes. Under the optimized conditions, the electroanalytical performance of Pd‐dispersed CPE in flow injection analysis was excellent, with good reproducibility (RSD 3.3%) and a wide linear range (1.9×10?7 to 1.0×10?4 mol L?1). A detection limit of 1.4×10?8 mol L?1 (0.14 ng maleic hydrazide) was obtained for a sample loop of 100 μL at a fixed potential of 700 mV in 0.050 M phosphate buffer solution at pH 7.0 and a flow rate of 2.0 mL min?1. The proposed method was applied for the maleic hydrazide detection in natural drinking water samples.  相似文献   

6.
《Analytical letters》2012,45(8):1741-1750
Abstract

Ascorbic acid was determined indirectly by spectrophotometry at 666 nm based on the photochemical reduction of methylene blue using flow-injection analysis. The carrier stream was 12.7 μgml?1 methylene blue in phthalate-HCl buffer solution at pH 3.2. The reactor was irradiated with a 500-Watt halogen lamp to facilitate the development of the photochemical reaction. The system allows determination of ascorbic acid in the range 0.18–6.12 μgml?1 with relative standard deviations of 2.09 and 0.31% for 1.97 and 4.92 μgml?1 samples, respectively, and a sampling frequency of 50–55 h?1. The proposed method was applied successfully to the determination of ascorbic acid in vitamin C tablets.  相似文献   

7.
Alkali lignin undergoes strong adsorption on polycrystalline gold electrodes. Subsequent oxidation in a sulfuric acid solution leads to a restructured redox‐active polymer that shows features characteristic for surface confined species. Surface coverage of up to 4.40×10?10 mol cm?2 may be obtained depending on the adsorption time or lignin concentration in the adsorption solution. Using Laviron's approach the electron‐transfer rate constant and the transfer coefficient were found to be 8.9 s?1 and 0.35, respectively. The formal potential of the redox couple shifted negatively with pH at a rate of ca. 60 mV/pH unit, suggesting a 2 e/2 H+ reaction. The redox couple was also found to be a good mediator for electrochemical ascorbic acid oxidation in neutral phosphate buffer with ca. 250 mV reduction of the oxidation overpotential.  相似文献   

8.
For the construction of the sensor, three different carbon black (CB) materials (VULCAN XC72R, BLACK PEARLS 4750 and CB N220) were explored as modifying nanomaterial. Firstly, the electrochemical activity of the each SPE modified was compared by cyclic voltammetry and electrochemical impedance spectroscopy technique, using [Fe(CN)6]3?/4? as redox couple. After demonstrating that electrodes modified with different types of CB were characterized by improved electrochemical performances when compared with bare electrodes, and among them, electrodes modified with CB BP4750 is characterised by slightly better electrochemical properties, this type of electrode was used for the development of the analytical method. By applying SWV technique in 0.2 mol L?1 phosphate buffer (pH 3.0), the obtained analytical curves for ACP and LVF were found linearly from 4.0 to 80.0 μmol L?1 and from 0.90 to 70.0 μmol L?1 with limit of detection of 2.6 μmol L?1 and 0.42 μmol L?1 for ACP and LVF, respectively. Finally, the quantification of these drugs in river water was evaluated using the new here‐proposed sensor by recovery method in spiked samples, obtaining satisfactory recovery values. The results achieved demonstrated that the developed analytical tool is of great analytical interest being easy to use, cost‐effective, miniaturized, and thus suitable for low cost on site analysis.  相似文献   

9.
Meldola Blue (7-dimethylamino-1,2-benzophenoxazine) can be adsorbed on graphite to give chemically modified electrodes. The electrochemical redox reactions of the phenoxazine are fairly reversible at low coverages with an E′o of ?175 mV vs. SCE at pH 7.0. The electrode was most stable in acid solutions, at pH 6.0 its electrochemical activity decreased by 15% during 2h. The adsorbed compound mediated electron transfer in the electrocatalytic oxidation of the nicotinamide coenzymes (NADH and NADPH). The formation of a charge transfer complex between Meldola Blue and the coenzyme is demonstrated by experiments with a rotating disk electrode. The complex decomposes in a rate limiting step (k+2=30 s?1) to the oxidized coenzyme and the reduced Meldola Blue. The latter can be reoxidized in a fast electrochemical step. The overall result is an electrocatalytic oxidation at a voltage which is about 500 mV lower than at an unmodified electrode.  相似文献   

10.
《Electroanalysis》2005,17(19):1740-1745
A p‐chloranil modified carbon paste electrode was constructed and the electrochemical behavior of this electrode was studied in the aqueous solution with different pH. From the E1/2–pH diagram for this compound the values of formal potential E0' and pKa of some different redox and acid‐base couples depending on the solution pH were estimated. The diffusion coefficient, D, value for p‐chloranil was estimated 1.5×10?7 cm2 s?1. It has been shown by direct current cyclic voltammetry and double potential step chronoamperometry, that this p‐chloranil incorporated carbon paste electrode, can catalyze the oxidation of ascorbic acid in the aqueous buffered solution. Under the optimum condition (pH 7.00), the oxidation of ascorbic acid at the surface of such an electrode occurs at a potential about 325 mV less positive than that at an unmodified carbon past electrode. The catalytic oxidation peak currents was linearly dependent on the ascorbic acid concentration and a linear calibration curve was obtained in the range of 7×10?5 M–4×10?3 M of ascorbic acid with a correlation coefficient of 0.9998. The limit of detection (3σ) was determined as 3.5×10 ?5 M. This method was used as simple, selective and precise voltammetric method for determination of ascorbic acid in pharmaceutical preparations.  相似文献   

11.
《Electroanalysis》2006,18(12):1193-1201
A chemically modified carbon paste electrode with 2,7‐bis(ferrocenyl ethyl)fluoren‐9‐one (2,7‐BFEFMCPE) was employed to study the electrocatalytic oxidation of ascorbic acid in aqueous solution using cyclic voltammetry, differential pulse voltammetry and chronoamperometry. The diffusion coefficient (D=1.89×10?5 cm2 s?1), and the kinetic parameter such as the electron transfer coefficient, α (=0.42) of ascorbic acid oxidation at the surface of 2,7‐BFEFMCPE was determined using electrochemical approaches. It has been found that under an optimum condition (pH 7.00), the oxidation of ascorbic acid at the surface of such an electrode occurs at a potential about 300 mV less positive than that of an unmodified carbon paste electrode. The catalytic oxidation peak currents show a linear dependence on the ascorbic acid concentration and linear analytical curves were obtained in the ranges of 8.0×10?5 M–2.0×10?3 M and 3.1×10?5 M–3.3×10?3 M of ascorbic acid with correlation coefficients of 0.9980 and 0.9976 in cyclic voltammetry and differential pulse voltammetry, respectively. The detection limits (2δ) were determined to be 2.9×10?5 M and 9.0×10?6 M with cyclic voltammetry and differential pulse voltammetry, respectively. This method was also examined for determination of ascorbic acid in pharmaceutical preparations.  相似文献   

12.
In this paper, a silver doped poly(L ‐valine) (Ag‐PLV) modified glassy carbon electrode (GCE) was fabricated through electrochemical immobilization and was used to electrochemically detect uric acid (UA), dopamine (DA) and ascorbic acid (AA) by linear sweep voltammetry. In pH 4.0 PBS, at a scan rate of 100 mV/s, the modified electrode gave three separated oxidation peaks at 591 mV, 399 mV and 161 mV for UA, DA and AA, respectively. The peak potential differences were 238 mV and 192 mV. The electrochemical behaviors of them at the modified electrode were explored in detail with cyclic voltammetry. Under the optimum conditions, the linear ranges were 3.0×10?7 to 1.0×10?5 M for UA, 5.0×10?7 to 1.0×10?5 M for DA and 1.0×10?5 to 1.0×10?3 M for AA, respectively. The method was successfully applied for simultaneous determination of UA, DA and AA in human urine samples.  相似文献   

13.
A method is described for the production of screen-printed graphite electrodes and also for similar electrodes chemically modified with the electrocatalyst cobalt phthalocyanine. Using cyclic voltammetry, the electrochemical behaviour of these electrodes towards ascorbic acid, reduced glutatione and coenzyme A (CoA-SH) was investigated. The modified electrodes were found to give significant decreases in the over-potential required for the oxidation of these species at carbon electrodes. The useful electrochemical window for the unmodified carbon film electrodes was ?1.08 V to +0.85 V vs. SCE, using 1 μA background current cut-off points.Amperometry in stirred solutions was used to investigate the hydrodynamic behaviour of the electrodes and their calibration performance. The limits of detection for ascorbic acid and reduced glutathione at the modified films were 5 × 10?8 and 1 × 10?7 M, respectively. The calibration graphs were also linear up to 2 mM concentrations of both analytes. Using differential-pulse voltammetry, linear calibration graphs were obtained for both species up to 2.5 mM. This technique was also used to assess the reproducibility of the electrode manufacture; the coefficient of variation was 2.8% for 1.49 mM ascorbic acid and 6.9% for 0.92 mM reduced glutathione.  相似文献   

14.
In present work a simple methodology for electroanalytical sensing of diethylstilbestrol (DES) using graphene quantum dots (GQD) surface modified screen‐printed electrodes (SPE) is reported. GQD was synthesized by simple bottom‐up method based on citric acid pyrolysis at 200 °C and electrodeposited directly at electrode surface under cyclic voltammetric conditions. The obtained GQD presented an average diameter of 7 nm and was characterized by techniques such as transmission and scanning electron microscopy, and electrochemical impedance spectroscopy. The proposed sensor exhibits a linear response from 0.05 to 7.5 μmol L?1, with limit of detection and quantification of 8.8 nmol L?1 and 29.0 nmol L?1, respectively. The repeatability study presented RSD=3.6 % for 6 consecutive measurements using the same electrode surface and the reproducibility study showed RSD=6.6 % for measurements with 6 different electrode surfaces. The proposed sensor was successfully applied for DES determination in synthetic urine and tap water spiked samples and good recoveries were obtained without any sample pre‐treatment, showing its promising analytical performance.  相似文献   

15.
本实验制备了一种新型的氮杂铜配合物修饰金电极,该电极可用于抗坏血酸的测定。采用循环伏安法和扫描电化学显微镜技术对电极进行了表征。该修饰电极可催化氧化抗坏血酸,相对于裸电极抗坏血酸在修饰电极上氧化电位移动了250mV,并且氧化电流在抗坏血酸的浓度为5.0×10−7 to 4.0×10−5 mol/L时呈线性关系,检测限为4.8×10-8 mol/L。用此方法测定抗坏血酸与文献报道的测定结果一致,这表明该电极可用作抗坏血酸测定的电化学传感器。  相似文献   

16.
We report loading of vitamin C (ascorbic acid) on to lysozyme-shelled microbubbles. The interaction between lysozyme-shelled microbubbles and vitamin C was studied by use of cyclic and differential pulse voltammetry, zeta potential measurements, and scanning electron microscopy. The effect of microbubbles on electrochemical measurement of ascorbic acid was evaluated. The linear range for ascorbic acid obtained for differential pulse measurement in the presence of 1 mg mL?1 microbubbles was 1–50 μmol L?1 (y?=?0.067x?+?0.130, r 2?=?0.995), with a detection limit of 0.5 μmol L?1. The experimental conditions, i.e., pH and ionic strength, were optimized to improve the interaction between ascorbic acid and lysozyme-shelled microbubbles. The results were satisfactory when the interaction was performed for 1 h in aqueous solution at pH 6. The amount of vitamin C loaded on the microbubbles (90 % of the analyte added, RSD inter-expt. = 3 %, n?=?6) and the stability of microbubbles–ascorbic acid complex (until 72 h at 25 °C) were also evaluated by use of differential pulse voltammetry and zeta potential measurements.
Figure
Schematic figure of the interaction between LSμB (positively charged) and ascorbic acid (negatively charged). Ultrasound (US) assisted breaking of the LSμB's shell causes the release of drug located on the surface of the microbubbles  相似文献   

17.
Two spectrophotometric methods, a photochemical and a non-photochemical, for the determination of ascorbic acid in soft drinks and beer using a flow-injection system are proposed. The non-photochemical method is based on the redox reaction that takes place between ascorbic acid and Fe(III), yielding dehydroascorbic acid and Fe(II). Fe(II) reacts with 1,10-phenantroline, originating the reddish orange Fe(phen)3 2+ complex (ferroin). This complex is spectrophotometrically monitored at 512 nm, and the signal is directly related to the concentration of ascorbic acid in the sample. The photochemical method has the same basis, nevertheless, uses the irradiation with visible light to enhance the redox reaction and so achieve higher sensitivities in the analysis. The non-photochemical method shows a linear range between 5 and 80 μg mL?1, with a relative standard deviation of 1.6% (n = 11), a detection limit of 2.7 μg mL?1 and a sample throughput of ¶60 samples h?1. The photochemical method shows a linear range between 1 and 80 μg mL?1, with a relative standard deviation of 1.0% (n = 11), a detection limit of 0.5 μg mL?1 and a sample throughput of 40 samples h?1.  相似文献   

18.
Despite its excellent properties, the inherent unstable nature of black phosphorus (BP) in ambient atmosphere has severely restricted its use in electrochemical sensing applications. In this work, polyaniline (PANI) sheathed BP was prepared via the electrochemical polymerisation of aniline on BP coated screen printed carbon electrode (i. e., SPCE/BP) which resulted in an efficient, stable electrochemical platform (i. e., SPCE/BP@PANI) with improved properties which was evaluated for electrochemical detection of two model bioanalytes namely, ascorbic acid (AA) and Hydrazine (Hy). The formation of PANI on the SPCE/BP exhibited a pair of stable and well‐defined redox peaks indicating the better adsorption energy and fast electron transfer nature of BP as compared to other 2D materials like graphene and transitional metal dichalcogenides. FESEM and XPS studies revealed the formation and uniform growth of PANI on BP surface without any aggregation. Electrochemical impedance spectroscopy analyses revealed that SPCE/BP@PANI can act as a suitable electrocatalyst material for the sensing of AA and Hy. Thus, SPCE/BP@PANI electrode exhibited low limit of detection (DL; 1.69 μM), excellent reproducibility and better selectivity towards AA oxidation over glucose, sucrose, urea, citric acid, sodium, nitrate, nitrite and magnesium with a sensitivity of 3.38 A M?1 cm?2 (R2=0.98) in the dynamic range of 10–1100 μM. The excellent analytical performance of the BP@PANI is plausible due to better adsorption energy and fast electron transfer of BP. Further, SPCE/BP@PANI was also used for successful detection of AA in processed fruit juice with good recovery. Under the optimal DPV conditions, the modified electrode was extended for detection of Hy in a linear range of 100–1500 μM with sensitivity of 0.09 A M?1 cm?2 (R2=0.99) and DL=89 μM validating the potential of BP based composites in wide range of electrochemical applications.  相似文献   

19.
The electrochemical behavior of NADH, xanthine, uric acid, 6-mercaptopurine, 6-thioxanthine, dopamine and ascorbic acid was investigated at the organic metal-like polymer paste electrodes, tetrathiafulvalene- and N-methylphenazene-tetracyanoquinodimethane. The reactivity of small biological molecules at polymer paste electrodes is generally lower than at most active graphite electrodes. Typical detection limits of about 10?5 M and the typical upper limit of linearity of 10?3 M are observed for the compounds studied.  相似文献   

20.
This paper describes a rapid and sensitive method for determination of the hair dye Basic Blue 41 in wastewater samples using screen‐printed carbon electrodes modified with graphene (SPCE/Gr). The method is based on the reversible reduction of azo groups of the dye at potential of ?0.23 V/?0.26 V, where both the anodic and cathodic currents increased 1,300 % when compared to screen‐printed carbon (SPCE) and glassy carbon electrodes (GCE). The optimization of a square wave voltammetric method was performed by means of 23 factorial design, Doehlert matrix and multi‐response assays, and the best parameters were: frequency (54.8 Hz), step potential (6 mV), pulse amplitude (43.7 mV) and pH 4.5. The analytical curve was constructed from 3.00×10?8 to 2.01×10?6 mol L?1, with detection and quantification limits of 5.00×10?9 and 1.70×10?8 mol L?1, respectively. The repeatability of the method evaluated for 10 consecutive measurements at concentrations of 1.70×10?7 mol L?1 and 1.70×10?6 mol L?1, showed relative standard deviation of 3.56 and 0.57 %, respectively. The sensor based in SPCE/Gr was successfully applied in wastewater samples collected from a drinking water treatment plant and validated by comparison with HPLC‐DAD method with good accuracy.  相似文献   