首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A method based on the infrared hollow waveguide sampler was developed for sensing chlorophenols in aqueous solutions. This sampler was constructed by coating a suitable hydrophobic film onto the inner surface of an infrared hollow waveguide. By passing the aqueous solution through the hollow waveguide sampler, analytes can be absorbed into the hydrophobic layer. The adsorbed analytes can be sensed later by using Fourier transform infrared spectrometry. Six hydrophobic polymers were investigated for their performance in conjunction with the infrared hollow waveguide sampler for the detection of chlorophenols. Results indicated that poly(acrylonitrile-co-butadiene) was a most suitable hydrophobic material for absorption of chlorophenols in aqueous solutions. To further increase the detection sensitivity, factors such as sampling flow rate, sampling time, and thickness of the hydrophobic film were also investigated. Results indicated that the infrared signals were similar in the examined flow rates (2-30 mL/min), but that a higher flow rate tended to produce a higher analytical signal. Fast detection speed was an advantage of this method for the detection of chlorophenols, and the sampling/detection time can be <10 min. In addition, analytical signals were nearly proportional to the thickness of the hydrophobic film coating the inside of the hollow waveguide. With the optimal conditions found in this work, detection limits based on 3 times the peak-to-peak noise level were around 300 ppb for the chlorophenols examined. A high degree of linearity in the standard curves was also observed for this method in the concentration range of 10-100 ppm. The typical regression coefficients were >0.994 for the chlorophenols examined.  相似文献   

2.
An infrared reflection-absorption (IR/RA) method was developed to detect aromatic organic compounds in aqueous solutions where the required sample volume can be as low as 50 microL. Two aluminum plates were used to form the sampling cell for the detection of small amount of aqueous samples. One plate was used as an IR reflection substrate and a second plate, in which several holes were drilled, was placed tightly on the top of the reflection plate to form cavities for sampling. The cavities were further coated with hydrophobic film. After the hydrophobic film dried, a certain amount of aqueous sample was injected to the cavity. Analytes in the aqueous solution were attracted into the hydrophobic film through the solid phase micro-extraction principle. After residual water was removed from the cavity, organic compounds absorbed by the hydrophobic film could be sensed using IR radiation based on the reflection-absorption mode. To investigate the applicability of this type of sensing method for small-volume detection, factors such as the volume of the aqueous solution, the sample concentration, size of the cavity and the sensitivity of this method were investigated. An examination of the linear relationship between the signals and the analyte concentrations showed regression coefficients that were generally in the range of 0.992 to 0.999 for the examined analytes in the concentration range of 10 to 100 ppm. Under the condition that the sample volume was 100 microL and based on three-times the spectra noise level, the calculated detection limits for this method were found at around 1 ppm for the examined analytes.  相似文献   

3.
A combination of solid phase micro‐extraction (SPME) with attenuated total reflection (ATR) infrared spectrometry provides a fast and sensitive way to detect organic compounds in aqueous solutions. It is especially useful for detection of chlorinated organic compounds in environmental samples. Currently, analyses of organic compounds in aqueous solutions are limited to low‐polarity compounds by the SPME/ATR‐IR sensing method. This limitation was mainly caused by the low polarity nature of the SPME phase. To increase the capability of this method to detect more polar compounds and also to increase the sensitivity in detection of organic compounds, the principle of “like‐dissolve‐like” was used to design a specific SPME phase for a certain class of chlorinated compounds. To demonstrate this concept, chlorinated phenols were used as probe molecules and polyvinyl chloride was chemically modified with phenol, ‐naphthol and ‐naphthol to provide SPME phases with a similar chemical structure to chlorinated phenols. These polymers were used as SPME phases and their performance were compared with the commonly used SPME phases (i.e., polystyrene and polyisobutylene). Results indicated that naphthols attached to PVCs provided much lower compactness, which allows fast speed in absorption of phenols. Meanwhile, due to the structural similarity between naphthols attached to PVCs and phenols, much higher partition coefficients were found for these chemically modified PVCs than conventionally used polymers. To further increase the sensitivity for analysis of chlorinated phenols, the common influencing factors, such as pH values and salt effect were also investigated. Apparently, pH values of the solutions did not influence the structure of the modified PVCs significantly. In absorption of chlorinated phenols in aqueous solutions with different pH values, the observed IR signals were decreased greatly in pH higher than 6 due to the charged form of chlorinated phenols that were presented. Results of the salt effect indicated that three times stronger of IR signals can be obtained if 20% (w/vol) of NaCl was added.  相似文献   

4.
In this study, the cooling effect was applied to an evanescent wave type infrared (IR) chemical sensing method to effectively trap volatile organic compounds (VOCs), which have been absorbed in the hydrophobic film coated around the internal reflection element (IRE). The detection of VOCs in aqueous solutions was taken in the headspace of the aqueous solution. This method eliminates the long-term instability of hydrophobic film soaked in an aqueous solution and the potential spectral interference caused by the matrix of the aqueous solution. Thermal energy has been applied to the aqueous solution to assist in the evaporation of VOCs out of the aqueous matrix. By applying a cooling system to the IRE, the excess thermal energy can be removed leading to more stable IR signals. After examination of organic compounds with vapour pressure (Pv) ranging from 0.017 to 150 Torr, significant differences were found between IR signals from cooled and un-cooled systems. Because the thermal conductivity of the IRE used in IR detection is typically low; the efficiency in removing the thermal energy is limited. By heating the aqueous solutions to different temperatures, the IR signals showed that the sample temperature was limited to around 80 °C. The IR signal determination results for five different volatility organic compounds indicated that the optimal heating temperature was not necessary to match with the volatilities of organic compounds in cooling system. The linear regression coefficient (R2) of the standard curve for sample concentrations in the range 5-200 μg ml−1 was generally higher than 0.991 and the detection limit was around a few hundred ng ml−1, which was two to three times lower than that of un-cooled system.  相似文献   

5.
In this study, an infrared (IR) hollow waveguide sampler was developed to detect organic compounds in aqueous samples with sample volumes less than 50 microL. This sampler was prepared by coating a thin hydrophobic film inside the IR hollow waveguide. After injecting a certain amount of aqueous solution, organic compounds could be absorbed into the hydrophobic film by partitions. By removing the residual water in the hollow waveguide sampler with a nitrogen purging gas, the absorbed organic compounds could be sensed using IR radiation. To investigate the applicability of this hollow waveguide sampler in the detection of small amounts of aqueous samples, an analytical working function was developed following an examination of the parameters which influence the analytical signals. Such factors as the volume of the aqueous solution, the sample concentration, the length of the hollow waveguide, and the sensitivity of this method were investigated. Excellent agreement between the analytical and theoretical predicted values was observed. Upon examining the linear relationship between the analyte signals and the concentration, the regression coefficients were generally higher than 0.998 in the examined concentration range of 1 to 100 ppm. Under the condition that the sample volume was 300 microL and based on three-times the spectra noise level, the calculated detection limits for this method were found at around 1 ppm for the examined analytes.  相似文献   

6.
Yang J  Ramesh A 《The Analyst》2005,130(3):397-403
A novel membrane-introduced infrared (IR) chemical sensing method has been developed for the detection of volatile organic compounds (VOCs) in aqueous solutions. In this method, a porous Teflon membrane was used to eliminate the problems associated with conventional IR spectroscopic sensing methods. The porous Teflon membrane was sealed below an IR spectroscopic sensing element pre-coated with a hydrophobic film and a two-channel flow cell configuration was established. In this configuration, the aqueous sample was allowed to pass through the lower channel and the VOCs that penetrated through the membrane to the upper channel were detected by the IR sensor. In this manner, the performance of the sampling at the headspace was improved while the problems caused by the presence of water were eliminated. Meanwhile, using a purging channel allowed the sensing element to be regenerated rapidly and enabled automation of the detection process. The parameters that influenced the analytical signals were studied, such as the sampling flow rate, the pH and ionic strength of the sample solutions, the effect of the volatilities of the VOCs, and the regeneration efficiency of the sensing element. The results indicated that the analytical signals were insensitive to the sampling flow rate and to the pH and ionic strength of the sample solutions. The results obtained from the detection of seven different volatile compounds indicated that this method is highly suitable for the detection of organic compounds that have vapor pressures >1 Torr and that it is potentially usable for organic compounds that have vapor pressures between 20 mTorr and 1 Torr. The regression analysis of the standard curves indicated that a regression coefficient (R(2)) > 0.99 was obtainable in the concentration range from 1 to 100 microg mL(-1). The detection limits for the tested compounds were around a few hundred ng mL(-1).  相似文献   

7.
We have developed an on-line sensing method for the detection of volatile organic compounds (VOCs) in contaminated aqueous solutions by combining a microporous hollow fiber membrane with an infrared (IR) sensing system. Polypropylene microporous hollow fibers were used to separate the VOCs from the aqueous solution into the hollow fibers, which were purged countercurrently for detection by the IR sensing systems. An evanescent-wave-type IR sensing system was used to detect the VOCs that were purged from the hollow fibers. The sensing element was coated with polyisobutylene (PIB) to concentrate the VOCs for their detection. To study the performance of this system, we examined a number of factors, such as the purging flow rate, the sample flow rate, and the volatilities of the VOCs. The results indicate that an increase in the purging flow rate reduces the analytical signal significantly, especially for purging flow rates >2 mL/min. The pumping flow rate for the aqueous sample also influenced the analytical signals, but far less sensitively. The volatilities of the examined compounds also affected the analytical signals: the higher the volatility of the compound, the lower the intensity of the analytical signals and the shorter the time required to reach the equilibrium signal. From an examination of the dynamic range of this proposed method, a regression coefficient >0.994 was obtained for concentrations below 250 mg/L, even under non-equilibrium conditions. The response time of the system was studied in an effort to examine the suitability of using this sensing method for automatic detection. The results indicate that new equilibrium conditions were established within 3 min for highly volatile compounds, which suggests that on-line monitoring of the levels of VOCs can be performed in the field.  相似文献   

8.
In this paper, the selectivity and sensitivity of cyclodextrin (CD) modified infrared (IR) chemical sensor in detection of aromatic acids in aqueous solutions were reported. To eliminate the interference from water, the technique of attenuated total reflection was employed. By surface treated with CD molecules on the internal reflection elements, the sensors were selective in sensing of aromatic acids compared to aromatic compounds with other functional groups. To facilitate the use of this method for the quantitative analyses of aromatic acids in aqueous solutions, analytical functions were also developed in this work and a linear relationship between analytical responses and concentrations of analytes can be obtained. To optimize the analytical conditions, the factors that influence the IR spectroscopic signals were examined. These factors included response time, CD loadings of the sensors, pH effect on response, regeneration efficiency and stability of sensors. Under the optimal conditions, the detection limits for aromatic acids at a detection time of 2 min can be <100 μg/L. Meanwhile, the dynamic linear range for detection was only ca. two orders of magnitude if direct IR signals were used. Using the analytical function developed in this work, the linearity can be extended up to a concentration of 100 mg/L.  相似文献   

9.
The suitability of an integrated optical chemical sensor for the determination of highly volatile chlorinated hydrocarbons in aqueous solutions has been proven. The analytes are detected by NIR absorption spectrometry in the evanescent field of an integrated optical strip waveguide generated in a BGG31 (Schott, Germany) glass substrate, which is coated with a hydrophobic polymer superstrate as sensing layer. It has been shown that the sensitivity increases when the refractive index of the superstrate is increased from 1.333 up to 1.46. Different UV-cured polysiloxanes with low cross sensitivity to water have been prepared. Due to the good light transmission properties of the IO-sensors prepared by this method, quantitative measurements have been performed with the model system trichloroethene (TCE) in water. A detection limit of 22 ppm has been found and the sensor response times (t(90)-value) are between five and fourteen minutes for a coating thickness of around 30 microm. The sensor response is totally reversible. The analyte desorbes in air within 2 min. The enrichment of trichloroethene in the polysiloxane coating can be described by film diffusion through the aqueous boundary layer as rate determining step.  相似文献   

10.
A fiber coating from polyaniline (PANI) was electrochemically prepared and employed for solid phase microextraction (SPME) of some polycyclic aromatic hydrocarbons (PAHs) from water samples. The PANI film was directly electrodeposited on the platinum wire surface in sulfuric acid solution using cyclic voltammetry (CV) technique. The applicability of this coating was assessed employing a laboratory-made SPME device and gas chromatography with mass spectrometry (GC-MS) for the extraction of some PAHs from the headspace of aqueous samples. Application of wider potential range in CV led to a PANI with more stability against the temperature. The homogeneity and the porous surface structure of the film were examined by the scanning electron microscopy (SEM). The study revealed that this polymer is a suitable SPME fiber coating for extracting the selected PAHs. Important parameters influencing the extraction process were optimized and an extraction time of 40 min at 40 degrees C gave maximum peak area, when the aqueous sample was added with NaCl (20%, w/v). The synthesis of the PANI can be carried out conveniently and in a reproducible manner while it is rather inexpensive and stable against most of organic solvents. The film thickness of PANI can be precisely controlled by the number of CV cycles. The resulting thickness was roughly 20 microm after 20 cycles. At the optimum conditions, the relative standard deviation (RSD) for a double distilled water spiked with selected PAHs at ppb level were 8.80-16.8% (n = 3) and detection limits for the studied compounds were between 0.1-6 pg mL(-1). The performance of PANI was, also, compared with a commercial solid coated-based SPME fiber, carbowax/divinylbenzene (CW/DVB), under similar experimental conditions.  相似文献   

11.
The suitability of an integrated optical chemical sensor for the determination of highly volatile chlorinated hydrocarbons in aqueous solutions has been proven. The analytes are detected by NIR absorption spectrometry in the evanescent field of an integrated optical strip waveguide generated in a BGG31 (Schott, Germany) glass substrate, which is coated with a hydrophobic polymer superstrate as sensing layer. It has been shown that the sensitivity increases when the refractive index of the superstrate is increased from 1.333 up to 1.46. Different UV-cured polysiloxanes with low cross sensitivity to water have been prepared. Due to the good light transmission properties of the IO-sensors prepared by this method, quantitative measurements have been performed with the model system trichloroethene (TCE) in water. A detection limit of 22 ppm has been found and the sensor response times (t90-value) are between five and fourteen minutes for a coating thickness of around 30 m. The sensor response is totally reversible. The analyte desorbes in air within 2 min. The enrichment of trichloroethene in the polysiloxane coating can be described by film diffusion through the aqueous boundary layer as rate determining step.  相似文献   

12.
J Yang  M L Cheng 《The Analyst》2001,126(6):881-886
A new method, based on a combination of solid phase micro-extraction (SPME) and attenuated total reflection infrared (ATR-IR) spectroscopy, was developed for the detection of phenols in aqueous solutions. Several types of phenols were studied including phenols attached to methyl, hydroxyl, chlorine and nitro groups, which are environmentally toxic. Because of the polarity of the phenol-type compounds, the performance of six polymers in attracting phenols was investigated. Results indicated that poly(acrylonitrile-co-butadiene) was the most suitable SPME phase among the investigated polymers. To further increase the sensitivity in phenol detection, factors, such as the pH effect, salt effect and thickness of the SPME phase, were investigated. Results indicated that pH values affected the neutral form percentage of the analytes strongly and, hence, affected the detected signals. Due to the acid nature of phenols, phenol detection occurs best in solutions with a low pH value. A two- to three-fold increase in signals was observed after the addition of salt into the solution. The results on the examination of standard curve linearity indicated that the regression coefficients (R2) were higher than 0.996 for four types of phenols. The obtained detection limits for phenols were lower than 200 micrograms L-1 for most of the compounds.  相似文献   

13.
We fabricated porphyrin thin films on mica surfaces from acidic aqueous solutions of the preorganized H-aggregates of amphiphilic porphyrins by the simple spin-coating method. The morphological and spectroscopic properties of the film were investigated by scanning near-field optical microscopy. The results obtained in this study demonstrate that the preorganized structure in solution can be transferred as a thin film with a thickness of the monolayer level without losing their substantial structure and photophysical properties.  相似文献   

14.
The solid‐phase microextraction (SPME) technique using a 100 μm film polydimethylsiloxane (PDMS) coated fiber has been examined with the aim to determine dichlorobenzene in aqueous samples. The feasibility of SPME‐GC‐ECD analysis has been evaluated. Absorption time of 30 min was selected and 1 min was long enough for complete desorption of the analytes in the injection port of the gas chromatograph. Linear ranges from 0.03 to 5 μg/L and method detection limits between 7 and 9 ng/L for dichlorobenzenes were obtained. The relative standard deviations were less than 12% for a spiking level of 3 μg/L. The proposed method was applied to determine dichlorobenzenes in spiked deionized water, ground water, and in industrial effluent samples.  相似文献   

15.
An aniline-based polymer was electrochemically prepared and applied as a new fiber coating for solid phase microextraction (SPME) of some priority phenols from water samples. The polyaniline (PANI) film was directly electrodeposited on the platinum wire surface in sulfuric acid solution using cyclic voltammetry (CV) technique. The efficiency of new coating was investigated using a laboratory-made SPME device and gas chromatography with flame ionization detection for the extraction of some phenols from the headspace of aqueous samples. The scanning electron microscopy (SEM) images showed the homogeneity and the porous surface structure of the film. The results obtained proved the ability of this polymer as a suitable SPME fiber coating for trapping the selected phenols. Influential parameters affecting the extraction process were optimized and an extraction time of 50 min at 50 °C gave maximum efficiency, when the aqueous sample was saturated with NaCl and adjusted at pH 2. This new coating can be prepared easily in a reproducible manner and it is rather inexpensive and stable against most of organic solvents. The PANI thickness can be precisely controlled by the number of CV cycles. At the optimum conditions, the R.S.D. for a double distilled water spiked with phenol and chlorophenols at ppb level were 4.8-17% (n = 3) and detection limits for the studied compounds were between 0.69 and 3.7 ng ml−1, except for phenol and 4-chlorophenol. The optimized method was successfully applied to some real-life water samples.  相似文献   

16.
A simple and rapid solid-phase microextraction (SPME) method is presented based on activated charcoal–PVC fiber for determination of some organophosphorus pesticides from aqueous samples in direct mode SPME. After optimization of the experimental variables affecting SPME of the target compounds from aqueous solutions, the proposed method was applied to determine pesticides in fruit juice. The analytes in this procedure were preconcentrated for 15 min on the SPME fiber and subsequently desorbed by heating the fiber at 200 °C for 5 min in the GC injection port. Separation was on a capillary column GC followed by flame ionization detection. Recoveries of the pesticides studied in aqueous samples ranged 42%–63% and repeatability for all analytes was < 9% for a single fiber. Fiber-to-fiber reproducibility was < 18%.  相似文献   

17.
Topoglidis E  Lutz T  Willis RL  Barnett CJ  Cass AE  Durrant JR 《Faraday discussions》2000,(116):35-46; discussion 67-75
We have investigated the use of nanoporous TiO2 films as substrates for protein immobilisation. Such films are of interest due to their high surface area, optical transparency, electrochemical activity and ease of fabrication. These films moreover allow detailed spectroscopic study of protein/electrode electron transfer processes. We find that protein immobilisation on such films may be readily achieved from aqueous solutions at 4 degrees C with a high binding stability and no detectable protein denaturation. The nanoporous structure of the film greatly enhances the active surface area available for protein binding (by a factor of up to 850 for an 8 microns thick film). We demonstrate that the redox state of proteins such as immobilised cytochrome-c (Cyt-c) and haemoglobin (Hb) may be modulated by the application of an electrical bias potential to the TiO2 film, without the addition of electron transfer mediators. The binding of Cyt-c on the TiO2 films is investigated as a function of film thickness, protein concentration, protein surface charge and ionic strength. We demonstrate the potential use of immobilised Hb on such TiO2 films for the detection of dissolved CO in aqueous solutions. We further show that protein/electrode electron transfer may be initiated by UV bandgap excitation of the TiO2 electrode. Both photooxidation and photoreduction of the immobilised proteins can be achieved. By employing pulsed UV laser excitation, the interfacial electron transfer kinetics can be monitored by transient optical spectroscopy, providing a novel probe of protein/electrode electron transfer kinetics. We conclude that nanoporous TiO2 films may be useful both for basic studies of protein/electrode interactions and for the development of novel bioanalytical devices such as biosensors.  相似文献   

18.
A simple and sensitive method for determining anatoxin-a in aqueous samples was developed using solid-phase microextraction (SPME) and gas chromatography with mass spectrometry (GC-MS) detection. Three forms of polyaniline (PANI) films and a single form of polypyrrole (PPY) film were prepared and applied for SPME. The extraction properties of these films to anatoxin-a were examined and it was shown that leucoemeraldine form of PANI displayed a better selectivity to this compound. SPME conditions were optimized by selecting the appropriate extraction parameters, including type of coating (leucoemeraldine form of PANI at 32 microm thicknesses), salt concentration (10%, w/v), time of extraction (30 min) and stirring rate (1000 rpm). The calibration curve was linear in the range from 50 to 10,000 ng/ml, with the detection limit (S/N = 3) of 11.2 ng/ml. This method was successfully applied for the analysis of anatoxin-a in the cultured media of two species of cyanobacteria.  相似文献   

19.
Adsorption of bovine serum albumin at solid/aqueous interfaces   总被引:3,自引:0,他引:3  
Adsorption of soluble serum proteins on hydrophilic and hydrophobic solid surfaces is important for biomaterials and chromatographic separations of proteins. The adsorption of bovine serum albumin (BSA) from aqueous solutions was studied with in situ ATR-IR spectroscopy, and with ex situ ATR-IR, ellipsometry, and water wettablity measurements. The results were used to quantitatively determine the adsorbed film thickness and surface density of BSA on hydrophilic silicon oxide/silicon surfaces, and on these surfaces covered with a hydrophobic lipid monolayer of dipalmitoylphosphatidylcholine (DPPC). The water contact angles were 5° for silicon oxide, 47° ± 1° for the DDPC monolayer, and 53° ± 1° for the BSA monolayers. At 25 °C, and with 0.01–1 wt% BSA in water, the surface densities range from Γ = 2.6–5.0 mg/m2, and the film thicknesses range from d = 2.0–3.8 nm, on the assumption that the film is as dense as bulk protein. These results, and certain changes in the IR amide I and II bands of the protein, indicate that the protein adsorbs as a side-on monolayer, with some flattening due to unfolding or denaturation. The estimated -helical content for protein in buffer solutions is 15% higher than for solutions in water. The adsorption density reaches a steady-state value within 10 min for the lowest concentration, but does not appear to reach a steady-state value after 3 h f‘or the higher concentrations. Adsorption of BSA on a silicon oxide surface covered with a monolayer of DPPC leads to an adsorbed protein film of about half the thickness and surface density than on silicon oxide, but the same contact angle, indicating more protein unfolding on the hydrophobic than on the hydrophilic surface.  相似文献   

20.
The effect of solvent conditions on the growth of polyelectrolyte (PE) multilayer films comprising poly(allylamine hydrochloride) (PAH) and poly(styrenesulfonate sodium salt) (PSS) on planar substrates was investigated by means of surface plasmon resonance spectroscopy (SPRS), quartz crystal microbalance (QCM), and atomic force microscopy techniques. The solvent quality was varied by the addition of ethanol to the PE solutions used for deposition of the layers, thus tuning the relative strength of electrostatic and secondary intermolecular and intramolecular interactions. Experiments were performed with PE solutions both without added electrolyte and containing 0.5 M NaCl. Decreasing the solvent quality (i.e., increasing the amount of ethanol in the adsorption solution) resulted in a marked increase of both the multilayer film thickness and mass loading, as determined from the SPRS spectra and QCM frequency shifts, respectively. With the solution composition approaching the precipitation point, thick PAH/PSS films were formed due to the screening of the electrostatic intra- and interchain repulsions and enhanced hydrophobic interactions between the polyelectrolyte chains. However, the films formed from water/ethanol mixtures remained stable upon subsequent exposure to water or salt-containing solutions: no significant film desorption occurred after up to 24 h of exposure to water or 0.5 M NaCl solutions. In addition, the effect of postdeposition exposure to water/ethanol mixtures was investigated for PE multilayers assembled from aqueous solutions. In this case, the optical thickness of the films was determined during exposure to water/ethanol mixtures, and instead of swelling, the polyelectrolyte films collapse to the surface as a result of the unfavorable segment-solvent interactions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号