首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple, economic, selective, precise, and accurate high-performance liquid chromatographic (HPLC) method for the analysis of trimetazidine hydrochloride in both bulk drug and pharmaceutical formulations was developed and validated in the present study. The mobile phase consisted of water: methanol: triethylamine (75: 25: 0.1 v/v/v), and pH 3.3 was adjusted with orthophosphoric acid. This system was found to give a sharp peak of trimetazidine hydrochloride at a retention time of 3.375 ± 0.04 min. HPLC analysis of trimetazidine hydrochloride was carried out at a wavelength of 232 nm with a flow rate of 1.0 mL/min. The linear regression analysis data for the calibration curve showed a good linear relationship with a regression coefficient of 0.997 in the concentration range of 5–90 μg/mL. The linear regression equation was y = 35362x − 8964.2. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 3.6 and 10.9 μg/mL, respectively. The developed method was employed with a high degree of precision and accuracy for the analysis of trimetazidine hydrochloride. The developed method was validated for accuracy, precision, robustness, detection, and quantification limits as per the ICH guidelines. The wide linearity range, accuracy, sensitivity, short retention time, and composition of the mobile phase indicated that this method is better for the quantification of trimetazidine hydrochloride. The text was submitted by the authors in English.  相似文献   

2.
A new high-performance liquid chromatography assay was developed for the determination of minocycline in plasma and brain. A solid–liquid extraction procedure was coupled with a reversed-phase HPLC system. The system requires a mobile phase consisting of acetonitrile:water:perchloric acid (26:74:0.25, v/v/v) adjusted to pH 2.5 with 5 M sodium hydroxide for elution through a RP8 column (250 × 3.0 mm, i.d.) with UV detection set at 350 nm. The method proved to be accurate, precise (RSD < 20%) and linear between 0.15–20 μg mL−1 in plasma and 1–20 μg mg−1 in brain. The method was successfully applied to a blood-brain barrier minocycline transport study.  相似文献   

3.
A sensitive method based on high-performance liquid chromatography (HPLC) with ultraviolet (UV) detection was developed for the determination of carbamazepine (CBZ) and one of its active metabolites, carbamazepine-10,11-epoxide (CBZ-E) in human plasma. CBZ, CBZ-E and the internal standard (IS) 10,11-dihydrocarbamazepine were extracted from human plasma into methyl tert-butyl ether. CBZ, CBZ-E and the IS were successfully separated on an RP C18 column with a mobile phase of acetonitrile:methanol:water (18:19:63, v/v/v) and monitored via UV detection at 210 nm. The calibration curves were linear over the concentration ranges of 0.01–10 μg/mL for CBZ and 0.005–5 μg/mL for CBZ-E in human plasma, respectively. The method displayed excellent sensitivity, precision and accuracy, and was successfully applied to the quantification of CBZ and CBZ-E in human plasma after oral administration of a single 200 mg CBZ CR tablet. This method is suitable for bioequivalence studies following single doses given to healthy volunteers.  相似文献   

4.
An analytical method was developed to determine the benzimidazole fungicides and their residues (benomyl, carbendazim, thiabendazole and fuberidazole) in real water samples. Analyses were performed by reverse phase (RP) HPLC with direct fluorescence detection with mobile phase methanol:water, 40:60 (v/v) with 0.6% (v/v) ammonia. The extraction of analytes from water samples was performed with the use of micellar systems. Specifically, oligoethylene glycol monoalkyl ether (Genapol X-080) and polyoxyethylene 10 lauryl ether (POLE) were used as extractants. The recoveries of fungicides obtained in spiked water samples ranged from 68% to 94% for Genapol and from 68% to 96% for POLE. The limit of detection (LOD) was lower than 6 g L–1 for carbendazim, 7 g L–1 benomyl, 0.15 g L–1 for thiabendazole and 0.01 g L–1 for fuberidazole in both surfactants.  相似文献   

5.
An analytical method for the speciation of selenomethionine, selenocystine, selenite and selenate by high performance liquid chromatography (HPLC) with atomic spectrometric detection is presented. An organic polymeric strong anion exchange column was used as the stationary phase in combination with an aqueous solution of 6 mmol L–1 of salicylate ion at pH 8.5 as the mobile phase which allowed the isocratic separation of the four selenium analytes within 8 minutes. The separated selenium species were detected on-line by flame atomic absorption spectrometry (FAAS) or inductively coupled plasma mass spectrometry (ICP-MS). The signal-to-noise ratio of the FAAS detector was optimized using a hydrogen-argon entrained-air flame and a slotted-tube atom trap (STAT) in the flame. The limit of detection (3 σ) achieved by the HPLC-FAAS system was 1 mg L–1 of selenium (100 μL injections) for each of the four selenium species. More powerful selenium detection was achieved using an ELAN 5000 ICP-MS instrument. Selenium was measured at m/z = 82. The ICP-MS signal intensity was enhanced by a factor of 3–4 after addition of 3% methanol to the chromatographic mobile phase and by using an increased plasma power input of 1300 W. The limit of detection achieved under these conditions was 1 μg L–1 (100 μL injections). The HPLC-ICP-MS system was used for selenium speciation of selenite and selenate in aqueous solutions during a BCR certification exercise and for selenium speciation in the certified reference material, BCR No. 402 White Clover. Extraction experiments revealed that the selenium species in the biological material were extractable only in the presence of water in the extraction medium. The results indicated that selenate and a compound of unknown identity U were present in the plant sample. Received: 4 September 1996 / Accepted: 12 December 1996  相似文献   

6.
Summary A rapid and accurate HPLC method is described for the simultaneous determination of acetaminophen, dextromethorphen hydrobromide and pseudoephedrine hydrochloride in a new cold formulation. Chromatographic separation of the three pharmaceuticals was performed on a Hypersil CN column (150×5.0 mm, 5 μm) with a mobile phase mixture of an ion-pairing solution, methanol and acetonitrile (25:57:18, v/v), at a flow rate of 1.0 mL min−1, with detection at 220 nm. Separation was complete in less than 10 min. The method was validated for linearity, accuracy, precision, limit of quantitation and robustness. Linearity, accuracy, and precision were found to be acceptable over the ranges of 2.06∼20.6 μg·mL−1 for acetaminophen, 0.202∼2.02 mg·mL−1 for pseudoephedrine hydrochloride and 0.042∼1.06 mg·mL−1 for dextromethorphen hydrobromide.  相似文献   

7.

Abstract  

A stereoselective HPLC method has been developed for the simultaneous determination of oxprenolol enantiomers in urine and pharmaceutical products. Enantiomeric resolution of oxprenolol was achieved on cellulose tris(3,5-dichlorophenylcarbamate) immobilized onto a 5 μm spherical porous silica chiral stationary phase (CSP) known as Chiralpak IC with UV detection at 273 nm. The mobile phase consisted of n-hexane:isopropanol:triethylamine 70:30:0.1 (v/v/v) at a flow rate of 1.0 cm3/min. The method was validated for its linearity, accuracy, precision, and robustness. The calibration curves were linear over the range of 0.5–75 μg/cm3, with a detection limit of 0.1 μg/cm3 for each enantiomer. An average recovery of 99.0% and a mean relative standard deviation of 2.6% at 40.0 μg/cm3 for S-(−)- and R-(+)-enantiomers were obtained. The overall recoveries of oxprenolol enantiomers from pharmaceutical formulations were in the range 97.5–99.0%, with RSDs ranging from 0.6 to 0.8%. The mean extraction efficiency of oxprenolol from urine was in the range of 86.0–93.0% at 0.5–5 μg/cm3 for each enantiomer. The assay method proved to be suitable as a chiral quality control for oxprenolol formulations using HPLC and for therapeutic drug monitoring.  相似文献   

8.
Summary Lopinavir is a new specific and potent HIV-1 protease inhibitor. A rapid high-performance liquid chromatographic method using UV detection, has been developed and validated for the analysis of lopinavir in plasma. This involved a single liquid-solid extraction on an OASIS? HLB column in the presence of an internal standard. Separation was achieved on a Xterra?, C8 (150×3.9 mm I.D.) column with a mobile phase consisting of acetonitrile and water (41∶59, v/v). The detection wavelength was 210 nm. The assay was linear from 0.187 to 10.0 μg.mL−1 and the limit of quantification was 0.187 μg.mL−1. Mean recovery was ranged from 90.7% to 97.8% for lopinavir and 97.1% for the internal standard. Day to day precision and accuracy were less than 9.6% and 7.3% respectively. This rapid and simple method can readily be used for drug monitoring of lopinavir, in HIV-1 infected patients.  相似文献   

9.
A method for the determination/identification of residual sulfadimidine (SDD) in milk and eggs by high-performance liquid chromatography (HPLC) with a photo-diode array detector was developed. The sample preparation was performed by shaking with a mixture of 20% (w/v) trichloroacetic acid-methanol (4:1, v/v) followed by ultra-filtration using Molcut II?. A LiChrospher? 100 RP-8 (e) column and a mobile phase of 4% (v/v) acetic acid solution-acetonitrile (6:4, v/v) were used. The average recoveries from spiked SDD samples were 80.8–88.0% with coefficients of variation of 2.8–5.5%. The limits of detection in milk and eggs were 0.01 μg/mL and 0.01 μg/g, respectively. The total time required for the analysis of one sample was less than 20 min. Received: 7 October 1998 / Revised: 29 December 1998 / Accepted: 30 December 1998  相似文献   

10.
Summary A simple, rapid and accurate, routine-HPLC method is described for simultaneous determination of acetaminophen, caffeine and chlorpheniramine maleate in a new tablet formulation Chromatographic separation of the three pharmaceuticals was achieved on a Hypersil CN column (150×5.0 mm, 5 μm) using a mobile phase comprising a mixture of acetonitrile, an ion-pair solution and tetrahydrofuran (13:14:87, v/v,pH4.5). The flow-rate was changed from 1.0 mL min−1 (in 0≈7.5 min) to 1.8 mL min−1 (after 3.5 min). was complete in <10 min. The method was validated for system suitability, linearity, accuracy, precision, limits of detection and quantitation, and robustness. Linearity, accuracy and precision were found to be acceptable over the ranges 31.6≈315.8 μg mL−1 for acetaminophen, 9.5≈94.6 μg mL−1 for caffeine and 1.4≈13.8 μg mL−1 for chlorpheniramine maleate.  相似文献   

11.
This paper describes the validation of an isocratic LC method for the assay of linezolid in tablets. Validation parameters such as linearity, precision, accuracy, specificity, limit of detection, limit of quantitation and robustness were determined. LC was carried out by reversed phase technique on an RP-18 column with a mobile phase composed of 1% acetic acid:methanol:acetonitrile (50:25:25, v/v/v). Linezolid and your combination drug product were exposed to acid, base, oxidation, dry heat and photolytic stress conditions. A linear response (r > 0.9999) was observed in the range of 8.0–20.0 μg mL−1. The retention time of linezolid was 4.6 min. The method showed good recoveries and intra- and inter-day relative standard deviations were less than 1.0%. The LOD and LOQ were 0.21 and 0.63 μg mL−1, respectively. The developed LC method for determination of related substances and assay determination of linezolid can be used to evaluate the quality of regular production samples. It can also be used to test the stability samples of linezolid.  相似文献   

12.
A new and simple isocratic high-performance liquid chromatographic method with ultraviolet detection is described for simultaneous determination of active guaiphenesin and preservative sodium benzoate in Liqufruta garlic cough medicine formulation. The chromatographic separation was achieved using a Zorbax CN; 150 mm × 4.6 mm and 5 μm particle size column employing acetonitrile and water (20: 80, v/v) containing 0.1% formic acid (pH 3.5 ± 0.05) as the mobile phase. The method was validated with respect to linearity, range, precision, accuracy, specificity, limit of detection and limit of quantitation. The both analytes were detected by UV-Vis detector at 245 nm. The method was linear over the concentration range of 0.2–0.8 mg/mL and 0.02–0.06 mg/mL for guaiphenesin and sodium benzoate, respectively. The limit of detection was found to be 0.14 μg/mL for GP and 0.06 μg/mL for SB and the quantification limit was 0.54 μg/mL for GP and 0.22 for SB. Accuracy, evaluated as recovery, was in the range of 97.8–100.0%. Intra-day precision and intermediate precision showed relative standard deviation <1% in each case.  相似文献   

13.
Reversed-phase ion-pair liquid chromatography is often used to analyse traces of EDTA in natural water samples. Some perturbations due to the presence of major anions in samples, which can compete for ion pair formation with the Fe-EDTA complex used for the detection, have been observed but never estimated and quantified. A new operational method for determining EDTA in natural water samples is proposed by taking into account anion interactions. Qualitative and quantitative analyses of EDTA were performed with a synthetic water at various ionic strengths. From the effect of the ionic strength controlled by CaCl2, the concentration of the counter-ion tetrabutylammonium bromide (TBA+Br) and the methanol of the mobile phase, optimal analytical conditions were proposed for a better determination of EDTA concentration. The limit of detection without preconcentration and the reproducibility defined as relative standard deviation were 5 μg/L and 3.6% (n = 12), respectively. This method was applied to natural samples. Received: 15 March 1999 / Revised: 30 March 1999 / Accepted: 31 March 1999  相似文献   

14.
A simple and sensitive stability-indicating chiral HPLC method has been developed and validated per International Conference on Harmonization guidelines for the determination of enantiomeric purity of eluxadoline (Exdl). The impact of different mobile phase compositions and chiral stationary phases on the separation of Exdl enantiomer along with process- and degradation-related impurities has been studied. Homogeneity of Exdl and stable results of Exdl enantiomer in all degraded samples reveal the fact that the proposed method was specific (stability indicating). Amylose tris(3,5-dichlorophenyl carbamate) stationary phase column Chiralpak IE-3 (150 × 4.6 mm, 3 μm) provided better resolution with polar organic solvents than cellulose derivative, crown ether, and zwitterion stationary phases and nonpolar solvents. The mobile phase consisted of acetonitrile, tetrahydrofuran, methanol, butylamine, and acetic acid in the ratio of 500:500:20:2:1.5 (v/v/v/v/v). Isocratic elution was performed at a flow rate of 1.0 mL/min, column temperature of 35°C, injection volume of 10 μL, and UV detection of 240 nm. The United States Pharmacopeia (USP) resolution of the Exdl enantiomer was found to be more than 4.0 within a 65-min run time. Exdl enantiomer detector response linearity over the concentration range of 0.859–4.524 μg/mL was found to be R2 = 0.9985. The limit of detection, limit of quantification, and average percentage recovery values were established as 0.283 μg/mL, 0.859 μg/mL, and 96.0, respectively.  相似文献   

15.
A high-performance liquid chromatography (HPLC) method for the determination of acetaldehyde in fuel ethanol was developed. Acetaldehyde was derivatized with 0.900 mL 2,4-dinitrophenylhydrazine (DNPHi) reagent and 50 L phosphoric acid 1 mol L–1 at a controlled room temperature of 15°C for 20 min. The separation of acetaldehyde-DNPH (ADNPH) was carried out on a Shimadzu Shim-pack C18 column, using methanol/LiCl(aq) 1.0 mM (80/20, v/v) as a mobile phase under isocratic elution and UV–Vis detection at 365 nm. The standard curve of ADNPH was linear in the range 3–300 mg L–1 per injection (20 L) and the limit of detection (LOD) for acetaldehyde was 2.03 g L–1, with a correlation coefficient greater than 0.999 and a precision (relative standard deviation, RSD) of 5.6% (n=5). Recovery studies were performed by fortifying fuel samples with acetaldehyde at various concentrations and the results were in the range 98.7–102%, with a coefficient of variation (CV) from 0.2% to 7.2%. Several fuel samples collected from various gas stations were analyzed and the method was successfully applied to the analysis of acetaldehyde in fuel ethanol samples.  相似文献   

16.
Electrothermal atomic absorption spectrometry (ETAAS) applying a Zeeman effect background correction system (ZEBC) and a tranverse heated atomizer was used to directly determine chromium in sea water. Calcium chloride (at a concentration of 20 mg L–1) was applied as chemical modifier with optimum charring and atomization temperatures of 1600°C and 2000°C, respectively. The detection limit was 0.2 μg L–1, by injecting 20 μL aliquot of sea water sample. This detection limit could be reduced further to 0.05 μg L–1, using multiple injections (injection of five 20 μL aliquot of sea water). The accuracy of the methods developed were confirmed by analyses of different certified reference materials. Finally, interferences from major and minor components of sea water are studied. Received: 20 February 1997 / Revised: 26 May 1997 / Accepted: 8 June 1997  相似文献   

17.
For the first time, a simple, selective and accurate high-performance liquid chromatography method with ultraviolet detection was developed and validated to quantify simultaneously three structurally related antiepileptic drugs; carbamazepine, oxcarbazepine, and the recently launched eslicarbazepine acetate and their main metabolites, carbamazepine-10,11-epoxide, 10,11-trans-dihydroxy-10,11-dihydro-carbamazepine, and licarbazepine. The method involves a solid-phase extraction and a reverse-phase C18 column with 5 cm length. The mobile phase consisting of water, methanol, and acetonitrile in the ratio 64:30:6 was selected as the best one and pumped at 1 mL/min at 40 °C. The use of this recent column and an aqueous mobile phase instead of buffers gives several advantages over the method herein developed; namely the fact that the chromatographic analysis takes only 9 min. The method was validated according to the guidelines of the Food and Drug Administration, showing to be accurate (bias within ±12%), precise (coefficient variation <9%), selective and linear (r 2 > 0.997) over the concentration range of 0.05–30 μg/mL for carbamazepine; 0.05–20 μg/mL for oxcarbazepine; 0.15–4 μg/mL for eslicarbazepine acetate; 0.1–30 μg/mL for carbamazepine-10,11-epoxide; 0.1–10 μg/mL for 10,11-trans-dihydroxy-10,11-dihydro-carbamazepine, and 0.1–60 μg/mL for licarbazepine. It was also shown that this method can adequately be used for the therapeutic drug monitoring of the considered antiepileptic drugs, carbamazepine, oxcarbazepine, eslicarazepine acetate, and their metabolites.  相似文献   

18.
A method for the determination of imidacloprid in paddy water and soil was developed using liquid chromatography electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS). Separation of imidacloprid was carried out on a Shimadzu C18 column (150 mm × 4.6 mm, 4.6 μm) with an acetonitrile-water (50: 50, v/v) mobile phase containing 0.1% of acetic acid. The flow rate was 0.3 mL/min in isocratic mode. The product ion at 209 m/z was selected for quantification in multiple-reaction monitoring scan mode. Imidacloprid residues in soil were extracted by a solid-liquid extraction method with acetonitrile. Water samples were filtered and directly injected for analysis without extraction. Detection limits of 0.5 μg/kg and 0.3 μg/L were achieved for soil and water samples, respectively. The method had recoveries of 90 ± 2% (n = 4) for soil samples and 100 ± 2% (n = 4) for water samples. A linear relationship was observed throughout the investigated range of concentrations (1–200 μg/L), with the correlation coefficients ranging from 0.999 to 1.000.  相似文献   

19.
The analysis of four nitrofuran veterinary drugs, nitrofurantoin, furazolidone, furaltadone and nitrofurazone, was optimized using reversed-phase liquid chromatography with a monolithic column and photo-diode array detection. The antibiotics were extracted from animal feeds by heating with acetonitrile. The isocratic mobile phase consisted of a 8:92 (v/v) acetonitrile/phosphate buffer (pH 4.5) at a flow-rate of 1 mL min−1. Peaks were identified by the retention characteristics and UV spectra. Detection limits in the water samples ranged between 0.21 and 0.27 μg L−1, and in the feed samples between 2.1 and 2.7 μg kg−1, depending on the nitrofuran. The procedure was applied to the control of nitrofuran residues in farm water for poultry and different animal feeds.  相似文献   

20.
Dispersive liquid–liquid microextraction (DLLME) has been used for preconcentration of trihalomethanes (THMs) in drinking water. In DLLME an appropriate mixture of an extraction solvent (20.0 μL carbon disulfide) and a disperser solvent (0.50 mL acetone) was used to form a cloudy solution from a 5.00-mL aqueous sample containing the analytes. After phase separation by centrifugation the enriched analytes in the settled phase (6.5 ± 0.3 μL) were determined by gas chromatography with electron-capture detection (GC–ECD). Different experimental conditions, for example type and volume of extraction solvent, type and volume of disperser solvent, extraction time, and use of salt, were investigated. After optimization of the conditions the enrichment factor ranged from 116 to 355 and the limit of detection from 0.005 to 0.040 μg L−1. The linear range was 0.01–50 μg L−1 (more than three orders of magnitude). Relative standard deviations (RSDs) for 2.00 μg L−1 THMs in water, with internal standard, were in the range 1.3–5.9% (n = 5); without internal standard they were in the range 3.7–8.6% (n = 5). The method was successfully used for extraction and determination of THMs in drinking water. The results showed that total concentrations of THMs in drinking water from two areas of Tehran, Iran, were approximately 10.9 and 14.1 μg L−1. Relative recoveries from samples of drinking water spiked at levels of 2.00 and 5.00 μg L−1 were 95.0–107.8 and 92.2–100.9%, respectively. Comparison of this method with other methods indicates DLLME is a very simple and rapid (less than 2 min) method which requires a small volume of sample (5 mL).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号