首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 43 毫秒
1.
A rapid and sensitive high-performance liquid chromatographic method is described for simultaneous determination of isoniazid methanesulphonate (IHMS) and its metabolites, such as isoniazid (INH) and acetylisoniazid (AcINH) in rabbit blood. According to stability studies, IHMS was most stable at pH 3-5. After acidifying the blood to pH 5.0, a suitable amount of acetonitrile was added to the supernatant for extraction and niacinamide served as an internal standard. After evaporation, the residue was reconstituted with phosphate buffer and aliquots of this solution were separated on a reversed-phase phenyl column by a mobile phase consisting of 0.25 mM tetrabutylammonium phosphate as a paired-ion reagent. UV detection was performed at 280 nm. Under these conditions, the between-run coefficients of variation of IHMS, INH and AcINH from 1 to 25 microns/ml were 4.7 +/- 2.5, 5.4 +/- 1.0 and 5.1 +/- 3.1%, respectively. Hence this sensitive, reproducible and accurate method was suitable for pharmacokinetic studies of IHMS.  相似文献   

2.
《Analytical letters》2012,45(15):2125-2135
A rapid, sensitive, and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method with hydrophilic interaction chromatography has been developed and validated for the simultaneous determination of isoniazid and acetylisoniazidin human plasma. Following precipitation of the protein, the analytes were extracted from human plasma, with high extraction recovery (>70%) for both Isoniazid and acetylisoniazid. The analytes were then separated using a hydrophilic interaction chromatography (HILIC) column and detected by electrospray ionization (ESI) mass spectrometry performed with a triple-quadrupole mass spectrometry. The quantification of the analytes was realized by low-energy collision dissociation tandem mass spectrometry (CID-MS/MS) using the multiple reaction monitoring (MRM) mode at m/z of 138.1→121.1 for isoniazid and m/z 180.1 → 138.1 for acetylisoniazid, respectively. The method was linear over the concentration range of 5–50,000 ng/mL for both. The intra-day and inter-day relative standard deviations (RSD) were less than 15% and the relative errors (RE) were all within 15%. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic studies of isoniazid related to NAT2 genetic polymorphism in healthy Chinese subjects. The results showed that there were significant differences in the pharmacokinetic parameters of isoniazid and acetylisoniazid between subjects with and without mutations in the NAT2 gene.  相似文献   

3.
In an effort to characterize the pharmacokinetic behavior of the antimitotic agent N-desacetylcolchicine a selective, sensitive high-performance liquid chromatographic method was developed for the determination of N-desacetylcolchicine, demecolcine and colchicine in serum or urine. To 0.5 ml of serum or 0.1 ml of urine diluted to 0.5 ml were added 50 microliters demecolcine (2 micrograms/ml) which serves as the internal standard. The sample was extracted using a C2 reversed-phase solid extraction column. N-Desacetyl-colchicine, colchicine and the internal standard were eluted from the column with methanol. The combined eluates were evaporated to dryness and the residue was reconstituted with water. The reconstituted sample was injected into a C18 reversed-phase column and eluted using a mobile phase consisting of 0.1 M potassium dihydrogenphosphate, 5 mM 1-pentanesulfonic acid in methanol and acetonitrile with a final pH of 6.0, at a flow rate of 1.5 ml/min. N-Desacetylcolchicine, colchicine and the internal standard were detected using a variable-wavelength ultraviolet detector at 254 nm. The limit of detection was 0.4 ng/ml for desacetylcolchicine and 4.0 ng/ml for colchicine. The method is linear over a concentration range of 1.0-200 ng/ml. The method has been shown to be a rapid, reliable method to monitor N-desacetylcolchicine levels in clinical trials in cancer patients.  相似文献   

4.
A high-performance liquid chromatographic method for the measurement of bumetanide in plasma and urine is described. Following precipitation of proteins with acetonitrile, bumetanide was extracted from plasma or urine on a 1-ml bonded-phase C18 column and eluted with acetonitrile. Piretanide dissolved in methanol was used as the internal standard. A C18 Radial Pak column and fluorescence detection (excitation wavelength 228 nm; emission wavelength 418 nm) were used. The mobile phase consisted of methanol-water-glacial acetic acid (66:34:1, v/v) delivered isocratically at a flow-rate of 1.2 ml/min. The lower limit of detection for this method was 5 ng/ml using 0.2 ml of plasma or urine. Nafcillin, but not other semi-synthetic penicillins, was the only commonly used drug that interfered with this assay. No interference from endogenous compounds was detected. For plasma, the inter-assay coefficients of variation of the method were 7.6 and 4.4% for samples containing 10 and 250 ng/ml bumetanide, respectively. The inter-assay coefficients of variation for urine samples containing 10 and 2000 ng/ml were 8.1 and 5.7%, respectively. The calibration curve was linear over the range 5-2000 ng/ml.  相似文献   

5.
A sensitive, selective and easy to use high-performance liquid chromatographic method for the determination of cicletanide, a new diuretic, in plasma, red blood cells, urine and saliva is described. After extraction of cicletanide together with an internal standard with diethyl ether, or diethyl ether-n-hexane (20:80) for urine, the sample extracts are chromatographed with water-methanol-acetic acid (50:50:0.3) as eluent on to a Nucleosil C18 column. Both compounds are detected by their ultraviolet absorption at 280 nm. The calibration graph was linear between 0.2 and 20 micrograms/ml for plasma and between 0.2 and 5 micrograms/ml for the other biological fluids. The sensitivity limit was 20 ng/ml for plasma, red blood cells and saliva and 30 ng/ml for urine. The coefficients of variation of the between-day assays did not exceed 4.6% in plasma, 8.3% in red blood cells, 7.8% in urine and 4.2% in saliva for the lowest concentrations studied. The application of the method to a pharmacokinetic study of cicletanide after a single oral therapeutic dose in humans is reported.  相似文献   

6.
A gradient elution high-performance liquid chromatographic method is described for the analysis of the beta-lactamase inhibitor tazobactam (YTR-830H) and a semi-synthetic parenteral penicillin, piperacillin, in human plasma, serum, bile and urine. The assay for plasma, serum and bile involves deproteinization with acetonitrile and the removal of lipids with dichloromethane; urine is diluted with buffer. Separation and quantitation are achieved using a mobile phase based on ion-suppression chromatography on a C18 reversed-phase column with ultraviolet detection at 220 nm. The limit of quantitation for both compounds is 1.0 microgram/ml in plasma, serum and bile using a 0.2-ml sample and 50.0 micrograms/ml in urine using a 0.1-ml sample. The method has been validated by preparing and analyzing a series of fortified samples (range 1.0-200 micrograms/ml for each compound in plasma, serum and bile and 50.0-10,000 micrograms/ml for each compound in urine). Excellent linearity, accuracy, precision and recovery were obtained. The method was not interfered with by other endogenous components, nor by other commonly administered antibiotics such as amoxicillin, mezlocillin, cefometazole and cefotaxime. The assay has been successfully applied to the analysis of samples from pharmacokinetic studies in man and animals.  相似文献   

7.
Abstract

A reversed-phase high-performance liquid chromatographic (RP-HPLC) assay for the determination of clavulanic acid in serum and urine is described. The clavulanic acid was assayed by reacting the sample with 1, 2, 4-triazole reagent which rapidly produces a derivative that has its UV absorption maximum at 317 nm. The resulting product was separated in a RP-18 column (μ-Bondapak, 10 μm) and detected at 313 nm. The method was applied to assays of clavulanate in serum and urine, and is reproducible with a lower limit of quantitation of 0.1 μ/Ml.  相似文献   

8.
A fully automated analytical system based on liquid-solid extraction combined with column liquid chromatography is described for the determination of diclofenac in plasma. After addition of pH 5 buffer and the internal standard solution to the plasma sample, both sample preparation via a C18 disposable extraction column and injection were performed by a Gilson ASPEC system. Diclofenac and the internal standard were separated on a reversed-phase column, using methanol-pH 7.2 phosphate buffer (56:44, v/v) as mobile phase at a flow-rate of 0.4 ml/min. The reproducibility and accuracy of the method were acceptable over the concentration range 31-3140 nmol/l in plasma.  相似文献   

9.
A simple, rapid and reproducible reversed-phase high-performance liquid chromatographic method for the simultaneous determination of benzoic acid (BA), phenylacetic acid (PAA) and their respective glycine conjugates hippuric acid (HA) and phenaceturic acid (PA) in sheep urine is described. The procedure involves only direct injection of a diluted urine sample, thus obviating the need for an extraction step or an internal standard. The compounds were separated on a Nova-Pak C18 column with isocratic elution with acetate buffer (25 mM, pH 4.5)-methanol (95:5). A flow-rate of 1.0 ml/min, a column temperature of 35 degrees C and detection at 230 nm were employed. These conditions were optimized by investigating the effects of pH, molarity, methanol concentration in the mobile phase and column temperature on the resolution of the metabolites. The total analysis time was less than 15 min per sample. At a signal-to-noise ratio of 3 the detection limits for ten-fold diluted urine were 1.0 microgram/ml for BA and HA and 5.0 micrograms/ml for PAA and PA with a 20-microliters injection.  相似文献   

10.
Summary Two methods were developed for the determination of CGP 6140 and its N-oxide metabolite. The first method was based on trace enrichment, rinsing on a first column (LiChroprep RP-2) andbackflush on the analytical column (Spherisorb ODS 1). The second method was based on trace enrichment onto a cartridge andforwardflush on the analytical column using the Advanced Automated Sample Processor (AASP). CGP 6140 and its N-oxide metabolite are spectrophotometrically detected at 405nm. The reproducibility and accuracy of the methods were convenient. The limits of quantitation (50nmol/l in plasma and 250 nmol/l in urine) were sufficient to follow the concentrations of CGP 6140 and its N-oxide metabolite after a 100mg single oral dose of CGP 6140 to volunteers.  相似文献   

11.
《Analytical letters》2012,45(17-18):1433-1447
Abstract

A simple, specific, rapid and sensitive method for the analysis of mecillinam in plasma and urine using high pressure liquid chromatography is described. The assay is performed by direct injection of a plasma protein free supernatant or a dilution of urine. A μBondapak phenyl column with an eluting solvent of 16% CH3CN-0.2% H3PO4 was used, with UV detection of the effluent at 220 nm. Desacetyl-cephalothin was used as the internal standard and quantitation was based on peak height ratio of mecillinam to that of the internal standard. The lowest concentration detectable without extraction was 0.25 μg/ml for plasma and 8.9 μg/ml for urine. No interference from plasma and urine was noted.  相似文献   

12.
A simple, rapid and sensitive assay method for plasma N tau-methylhistidine by isocratic high-performance liquid chromatography has been developed. The deproteinized plasma was treated with o-phthalaldehyde-2-mercaptoethanol. The derivatives were separated on a LiChrospher 100 RP-18 column within 10 min. The detection limit for N tau-methylhistidine was 0.5 pmol. The plasma N tau-methylhistidine content of beef cattle and dairy cows was 0.038 +/- 0.004 and 0.017 +/- 0.002 nmol/ml/kg, respectively.  相似文献   

13.
An automated high-performance liquid chromatographic assay for the determination of an aldosterone antagonist (I) is described using column switching for direct injection of urine samples. After dilution with buffered internal standard solution, the sample was injected onto a clean-up column (17 X 4.6 mm I.D.), dry-packed with C18 reversed-phase material (particle size 30 micron). Polar urine components were removed by flushing the clean-up column with water. Retained substances, including I and the internal standard, were desorbed by backflush elution onto a 5-micron ODS-silica analytical column (125 X 4 mm I.D.), separated with water-methanol-tetrahydrofuran, and detected at 295 nm. After backflushing the analytical column and re-equilibrating the clean-up column, the system was ready for the next injection. The limit of quantification was ca. 100 ng/ml, using a 100-microliter specimen of diluted urine. The mean inter-assay precision of the method up to 25.6 micrograms/ml was 2%. Practicability and accuracy of the new method were demonstrated by the application to excretion studies performed with human volunteers.  相似文献   

14.
A HPLC method with automated column switching was developed and validated for the determination of Ro 63-1908 in rat and cynomolgus monkey plasma. Human plasma was used for calibration and was also included in the validation process. Ro 63-1908 belongs to a class of neuroprotective N-methyl-D-aspartate (NMDA) receptor blockers which were in development for the treatment of stroke and traumatic brain injury. The method involves deproteinisation of plasma samples with ethanol and direct injection of the supernatant (1.4 ml) into the HPLC column-switching system. To prevent a breakthrough of the analyte and the internal standard on the precolumn (Purospher RP-18, 75x4 mm) due to the high ethanol content, the injection solution was diluted, on-line, using an additional pump and a T-piece. 1% ammonium acetate-ethanol (100:2, v/v) was used as mobile phase for injection, as well as for on-line dilution, resulting in pre-concentration of the analyte and the internal standard on the precolumn. As Purospher RP-18 is a non-endcapped stationary phase with a special selectivity for amines, the analyte and the internal standard could then be selectively eluted with 30% acetonitrile (without any buffer in the mobile phase) and transferred to the analytical column [consisting of two coupled columns (125+250x4 mm) packed with Superspher 60 RP-select B], where they were separated by gradient elution and detected by fluorescence detection. Compared to the use of a 125 mm long precolumn and dilution of the supernatant with ammonium acetate prior to injection, the 75 mm precolumn and the on-line dilution procedure allowed about one third shorter run times (21 min) and, therefore, a higher sample throughput. The limit of quantification was 1 ng/ml using 0.4 ml plasma. The method was applied to more than 670 plasma samples from pharmacokinetic and toxicokinetic studies and is also suitable for other matrices and NMDA receptor blockers.  相似文献   

15.
A rapid and reliable screening procedure using high-performance liquid chromatography for the detection of 23 diuretics (belonging to five different pharmacological groups) in urine has been developed. Two aliquots of 2-ml urine samples were extracted separately under acidic and basic conditions. The acidic and basic extracts were pooled, evaporated to dryness and reconstituted in methanol. The methanolic extract was injected onto a Hewlett-Packard Hypersil ODS C18 (5 microns) column (column I) and a Hewlett-Packard LiChrosorb RP-18 (5 microns) column (column II; an alternative column). The same gradient mobile phase was used for both columns. A diode array ultraviolet detector was set to monitor the signal to the integrator (Chem Station) at 230 and 275 nm. Recovery studies of the 23 diuretics were performed under acidic and basic conditions. The overall lower limits for detection on column I using both extraction procedures ranged from 0.5 to 1.5 micrograms/ml of urine (average 1.0 micrograms/ml). Amiloride, ethacrynic acid and probenecid could not be detected below 5 micrograms/ml of urine. No interference from the biological matrix was apparent. Amiloride could be detected in urine 4 h after oral administration of 15 mg of amiloride to a healthy volunteer, when the sample was extracted under alkaline conditions. The suitability of the screening method for the analysis of urine samples was tested by studying the variation with time of chlorthalidone, furosemide, probenecid, acetazolamide, quinethazone, spironolactone, bendroflumethiazide, bumetanide, triameterene and hydrochlorothiazide concentrations in the urine of normal human volunteers after minimum single or multiple (probenecid) doses.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

16.
A simple and selective high-performance liquid chromatographic method with ultraviolet detection at 215 nm for the determination for pemoline in rat plasma, urine and tissues is described. Pemoline in the samples was extracted with methylene chloride at pH 10 and the organic phase was evaporated after adding 5-methyl-5-phenylhydantoin used as an internal standard. Pemoline and the internal standard were separated on a Kaseisorb LC C8-60-5 reversed-phase column. The limits of determination of pemoline in 0.1-0.2 ml of plasma, urine and tissue homogenates were 2, 100 and 20 ng, respectively. The method should be useful for studies of the pharmacokinetics and distribution of pemoline in small animals.  相似文献   

17.
A high-performance liquid chromatographic method was developed for the simultaneous determination of haloperidol and reduced haloperidol in human plasma, urine and rat tissue homogenates using bromperidol as an internal standard. The method involved extraction followed by injection of 50-80 microliters of the aqueous layer onto a C18 reversed-phase column. The mobile phase was 0.5 M phosphate buffer-acetonitrile-methanol (58:31:11, v/v/v) and the flow-rate was 0.6 ml/min. The column effluent was monitored by ultraviolet detection at 214 nm. The retention times for reduced haloperidol, haloperidol and bromperidol were 5.4, 7.2 and 8.4 min, respectively. The detection limits for haloperidol and reduced haloperidol in human plasma were both 0.5 ng/ml, and the corresponding values in human urine were both 5 ng/ml. The coefficients of variation of the assay were generally low (below 10.7%) for plasma, urine, blood and tissue homogenates. No interferences from endogenous substances or any drug tested were found.  相似文献   

18.
A sensitive and specific bioanalytical method for quantitation of a novel antiemetic (ADR-851) in plasma and urine has been developed and validated. The drug and internal standard (metoclopramide) are extracted from the plasma matrix by solid-phase extraction on cyanopropyl bonded-phase columns. After extraction, samples are separated by isocratic reversed-phase high-performance liquid chromatography. The parent drug, internal standard and a yet unidentified metabolite are detected by fluorescence. The method requires 1.0 ml of plasma or 0.1 ml of urine and has a lower limit of quantitation of 2 ng/ml with 10.9% relative standard deviation (R.S.D.). Method linearity has been established over a 2-800 ng/ml range when 1.0 ml of plasma is used. The intra- and inter-day imprecisions for the method are typically better than 6% and 11% R.S.D., respectively, in both plasma and urine over the entire dynamic range. The pooled estimate of bias is less than 5% and attests to the excellent accuracy.  相似文献   

19.
A specific method for the determination of 10 alpha-methoxy-9,10-dihydrolysergol, a nicergoline metabolite (metabolite 2), in urine is described. Metabolite 2 was well separated from the urine components on a reversed phase column, Hypersil ODS 5 microns, using an acetonitrile:pH 3.5 phosphate buffer (40:60, v/v) as the mobile phase at a flow rate of 1 mL/min. UV detection was set up at 220 nm. After addition of a known amount of lysergamide as the internal standard, the compounds were extracted from alkalysed urine on a pre-packed glass column (Extrelut 1) with dichloromethane. With 0.5 mL urine, concentrations down to 0.56 mumol/L could be determined.  相似文献   

20.
A fully automated gradient high-performance liquid chromatographic method for the determination of isotretinoin, tretinoin and their 4-oxo metabolites in plasma was developed, using the column-switching technique. After dilution with an internal standard solution containing 20% acetonitrile, 0.5 ml of the sample was injected onto a precolumn (17 X 4.6 mm I.D.), filled with C18 Corasil 37-53 micron. Proteins and polar plasma components were washed out using 1% ammonium acetate-acetonitrile (9:1, v/v) as mobile phase 1. After valve switching, the retained components were transferred to the analytical column in the backflush mode, separated by gradient elution and detected at 360 nm by UV detection. Using two coupled reversed-phase columns (125 mm long), the separation of cis and trans isomers was possible, and all four compounds could be quantified down to 2 ng/ml of plasma. The inter-assay precision in the concentration range 20-100 ng/ml was between 1.0 and 4.7% for all compounds.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号