首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We have modified gold nanoparticles (AuNPs) with triazole acetamide to obtain a material for the sensitive and selective colorimetric determination of iodide. The functionalized AuNPs were prepared by a reductive single chemical step using a Cu(I)-catalyzed click reaction. The presence of iodide ions induces the aggregation of these AuNPs and results in a color change from wine-red to purple. The iodide-induced aggregation can be detected visually with bare eyes, but also by photometry. The detection limit is as low as 15 nM. The method displays excellent selectivity for iodide over other anions due to the selective interaction with the amido groups of the triazole. The method was applied to the determination of iodide in spiked lake waters.
Figure
New triazole acetamide functionalized gold nanoparticles (ATTP-AuNPs) for sensitive and selective colorimetric detection of I? were developed. ATTP-AuNPs showed excellent selectivity toward I? due to the interaction between the amide groups of ATTP and I?.  相似文献   

2.
Xiaoyu Cao 《Mikrochimica acta》2014,181(9-10):1133-1141
We have developed an ultra-sensitive electrochemical DNA biosensor by assembling probe ssDNA on a glassy carbon electrode modified with a composite made from molybdenum disulfide, graphene, chitosan and gold nanoparticles. A thiol-tagged DNA strand coupled to horseradish peroxidase conjugated to AuNP served as a tracer. The nanocomposite on the surface acts as relatively good electrical conductor for accelerating the electron transfer, while the enzyme tagged gold nanoparticles provide signal amplification. Hybridization with the target DNA was studied by measuring the electrochemical signal response of horseradish peroxidase using differential pulse voltammetry. The calibration plot is linear in the 5.0?×?10?14 and 5.0?×?10?9 M concentration range, and the limit of detection is 2.2?×?10?15 M. The biosensor displays high selectivity and can differentiate between single-base mismatched and three-base mismatched sequences of DNA. The approach is deemed to provide a sensitive and reliable tool for highly specific detection of DNA.
Figure
We have developed an ultra-sensitive electrochemical DNA biosensor by assembling probe (ssDNA) on a glassy carbon electrode modified with a composite made from molybdenum disulfide, graphene, chitosan and gold nanoparticles. The nanocomposite on the surface acts as relatively good electrical conductor for accelerating the electron transfer, while the enzyme tagged gold nanoparticles provide signal amplification. The biosensor displays high selectivity and can differentiate between single-base mismatched and three-base mismatched sequences of DNA  相似文献   

3.
A method was developed for the detection of the insecticide acetamiprid based on the strong interaction of the cyano group of acetamiprid with gold nanoparticles (AuNPs). The interaction results in the aggregation of gold nanoparticles and is accompanied by a color change from red to purple. The concentration of acetamiprid can be determined qualitatively and quantitatively by visually monitoring the color change or by using a spectrometer. Transmittance electron microscopy and UV-vis spectroscopy have been used to characterize the process. The experimental parameters were optimized with regard to the size of the AuNPs, pH, and incubation time. Under optimal experimental conditions, linear relationships between the logarithm of the concentration of acetamiprid and the absorbance were found over the range of 0.66 to 6.6???M for AuNPs with diameters of 22.0?±?1.0?nm and of 6.6?C66???M for AuNPs with diameters of 15.0?±?1.0?nm. This method was successfully applied to detect acetamiprid in vegetables.
Figure
A method was developed for the detection of acetamiprid based on the strong interaction of the cyano group of acetamiprid with gold nanoparticles. This method is rapid, sensitive and low-cost. It can be used for pesticide residues detection.  相似文献   

4.
A lipase-based electrochemical biosensor has been fabricated for the quantitative determination of target DNA. It is based on a stem-loop nucleic acid probe labeled with ferrocene containing a butanoate ester that is hydrolyzed by lipase. The other end of the probe DNA is linked, via carboxy groups, to magnetic nanoparticles. The binding of target DNA transforms the hairpin structure of the probe DNA and causes the exposure of ester bonds. This results in the release of electro-active ferrocene after hydrolysis of the ester bonds, and in an observable electrochemical response. The quantity of target DNA in the concentration range between 1?×?10?12 mol·L?1 and 1?×?10?8 mol·L?1 can be determined by measuring the electrochemical current. The method can detect target DNA with rapid response (30 min) and low interference.
Figure
A lipase-based electrochemical biosensor has been fabricated for the quantitative determination of target DNA. It is based on a stem-loop nucleic acid probe labeled with ferrocene containing a butanoate ester that is hydrolyzed by lipase. The method can detect target DNA with rapid response (30 min) and low interference.  相似文献   

5.
We describe here an aptasensor for the ultrasensitive detection of Staphylococcus aureus by electrochemical impedance spectroscopy (EIS). Single-stranded DNA was linked to a nanocomposite prepared from reduced graphene oxide (rGO) and gold nanoparticles (AuNP). Thiolated ssDNA was covalently linked to the AuNPs linked to rGO, and probe DNA was immobilized on the surface of an AuNP-modified glassy carbon electrode to capture and concentrate Staph. aureus. The probe DNA of the aptasensor selectively captures the target bacteria in its three-dimensional space, and these results in a dramatic increase in impedance. Scanning electron microscopy, cyclic voltammetry and EIS were used to monitor the single steps of the electrode assembly process. The effect was utilized to quantify the bacteria in the concentration range from 10 to 106 cfu mL?1 and with a detection limit of 10 cfu mL?1 (S/N?=?3). The relative standard deviation of Staphylococcus aureus detection was equal to 4.3 % (105 cfu mL?1, n?=?7). In addition to its sensitivity, the biosensor exhibits high selectivity over other pathogens.
Figure
Schematic representation of the GCE surface modification and the detection of S. aureus. Reduced graphene oxide and gold nanoparticle (AuNP) nanocomposite linked by single-stranded DNA was prepared and then used in an aptasensor for the ultrasensitive detection of Staphylococcus aureus through electrochemical impedance spectroscopy. The probe DNA of the aptasensor selectively captures the target bacteria in its three-dimensional space, and these results in a dramatic increase in impedance.  相似文献   

6.
Zearalenone (ZEN) is a nonsteroidal estrogenic mycotoxin produced by Fusarium graminearum on maize and barley. Because most current methods of ZEN detection rely on the use of low-stability antibodies or expensive equipment, we sought to develop a rapid, low-cost determination method using aptamers instead of antibodies as the specific recognition ligands. This work describes the isolation and identification of single-stranded DNA (ssDNA) aptamers recognizing ZEN using the modified systematic evolution of ligands by exponential enrichment methodology based on magnetic beads. After 14 rounds of repeated selection, a highly enriched ssDNA library was sequenced and 12 representative sequences were assayed for their affinity and specificity. The best aptamer, 8Z31, with a dissociation constant (K d) of 41?±?5 nM, was successfully applied in the specific detection of ZEN in binding buffer and in real samples based on a magnetic separation/preconcentration procedure. This analytical method provided a linear range from 3.14?×?10?9 to 3.14?×?10?5 M for ZEN, and the detection limit was 7.85?×?10?10 M. The selected aptamers are expected to be used in the potential development of affinity columns, biosensors, or other analytical systems for the determination of ZEN in food and agricultural products.
Figure
Determination of dissociation constant (K d) and specificity of aptamers recognizing zearalenone  相似文献   

7.
A novel enzyme-free electrochemical sensor for H2O2 was fabricated by modifying an indium tin oxide (ITO) support with (3-aminopropyl) trimethoxysilane to yield an interface for the assembly of colloidal gold. Gold nanoparticles (AuNPs) were then immobilized on the substrate via self-assembly. Atomic force microscopy showed the presence of a monolayer of well-dispersed AuNPs with an average size of ~4 nm. The electrochemical behavior of the resultant AuNP/ITO-modified electrode and its response to hydrogen peroxide were studied by cyclic voltammetry. This non-enzymatic and mediator-free electrode exhibits a linear response in the range from 3.0?×?10?5 M to 1.0?×?10?3 M (M?=?mol?·?L?1) with a correlation coefficient of 0.999. The limit of detection is as low as 10 nM (for S/N?=?3). The sensor is stable, gives well reproducible results, and is deemed to represent a promising tool for electrochemical sensing.
Figure
AuNPs/ITO modified electrode prepared by self-assembly method exhibit good electrocatalytic activity towards enzyme-free detection H2O2. The linear range of typical electrode is between 3.0?×?10?5 M and 1.0?×?10?3 M with a correlation coefficient of 0.999 and the limit detection is down to 1.0?×?10?8 M.  相似文献   

8.
We report on the construction of a label-free electrochemical immunosensor for detecting the core antigen of the hepatitis C virus (HCV core antigen). A glassy carbon electrode (GCE) was modified with a nanocomposite made from gold nanoparticles, zirconia nanoparticles and chitosan, and prepared by in situ reduction. The zirconia nanoparticles were first dispersed in chitosan solution, and then AuNPs were prepared in situ on the ZrO2-chitosan composite. In parallel, a nanocomposite was synthesized from AuNPs, silica nanoparticles and chitosan, and conjugated to a secondary antibody. The properties of the resulting nanocomposites were investigated by UV-visible photometry and transmission electron microscopy, and the stepwise assembly process was characterized by means of cyclic voltammetry and electrochemical impedance spectroscopy. An sandwich type of immunosensor was developed which displays high sensitivity to the HCV core antigen in the concentration range between 2 and 512?ng?mL?1, with a detection limit of 0.17?ng?mL?1 (at S/N?=?3). This immunosensor provides an alternative approach towards the diagnosis of HCV.
Fig
A sandwich-type immunosensor was constructed for the detection of HCV core Ag. AuNPs/ZrO2-Chits nanocomposites were prepared by in situ reduction method. AuNPs/SiO2-Chits nanocomposite integrated with secondary antibody (Ab2) without labeled HRP. The immunosensor displayed high sensitivity to HCV core antigen with a detection limit of 0.17?ng?mL?1 (S/N?=?3).  相似文献   

9.
A disposable electrochemical myeloperoxidase (MPO) immunosensor was fabricated based on the indium tin oxide electrode modified with a film composed of gold nanoparticles (AuNPs), poly(o-phenylenediamine), multi-walled carbon nanotubes and an ionic liquid. The composite film on the surface of the electrode was prepared by in situ electropolymerization using the ionic liquid as a supporting electrolyte. Negatively charged AuNPs were then adsorbed on the modified electrode via amine-gold affinity and to immobilize MPO antibody. Finally, bovine serum albumin was employed to block possible remaining active sites on the AuNPs. The modification of the electrode was studied by cyclic voltammetry and scanning electron microscopy. The factors affecting the performance of the immunosensor were investigated in detail using the hexacyanoferrate redox system. The sensor exhibited good response to MPO over two linear ranges (from 0.2 to 23.4 and from 23.4 to 300 ng.mL?1), with a detection limit of 0.05 ng.mL?1 (at an S/N of 3).
Figure
A disposable electrochemical immunosensor for myeloperoxidase based on the indium tin oxide electrode modified with an ionic liquid composite film composed of gold nanoparticles, poly(o-phenylenediamine) and carbon nanotubes.  相似文献   

10.
This work described a novel sensor for detection of l -tryptophan (Trp) by electrodeposition of gold nanoparticles (AuNPs) onto the poly(alizarin red S) film pre-cast on a glassy carbon electrode (GCE). Alizarin red S (ARS) was deposited on the surface of the GCE by electropolymerization, and gold nanoparticles (AuNPs) were attached onto the poly(ARS) film by electrodeposition, forming an AuNPs–PARS nanocomposite film-modified GCE (AuNPs–PARS/GCE). Then electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM) were used to characterize modified electrodes. The Nyquist diagrams of EIS indicated that the PARS film and AuNPs were successfully immobilized on the surface of GCE, and the electron transfer resistance value of electrode changed efficiently. The SEM image showed that the immobilized AuNPs were spherical in shape. The AuNPs–PARS/GEC displayed excellent amperometric response for Trp. The amperometric responses have two linear ranges from 0.02 to 0.5 μM and 0.5 to 20.0 μM, with sensitivities of 1.63(±0.08) and 0.21(±0.01)?μAμM?1, respectively. Its detection limit was 6.7 nM at a signal-to-noise ratio of 3. The proposed method was applied to determine Trp.
Figure
The procedure of the L-tryptophan sensor preparation  相似文献   

11.
Gold nanoparticles (AuNPs) were used as a new chemical modifier for the determination of arsenic and antimony in salt solutions by electrothermal atomic absorption spectrometry. The AuNPs were prepared by reducing chloroauric acid with sodium citrate. The effects of pyrolysis and atomization temperatures, the amounts of interferents and modifier on the sensitivities of arsenic and antimony were investigated. As and Sb remain in the graphite tube up to 1,100°C, which is sufficient for the determination of the two metals in certified reference materials and spiked sea water samples within a 95% confidence level with low RSD (<10%). The detection limits (N?=?10 at 3??) for As and Sb in sea water are 2.3???g?L-1 and 3.0???g?L-1, respectively. Almost no background as well as a blank value was detected for AuNPs.
Figure
Schematic illustration of the preparation of the TiO2@Au nanoparticles and modification with MUA  相似文献   

12.
Deoxyribonucleic acid (DNA) was electrochemically deposited on a carbon ionic liquid electrode to give a biosensor with excellent redox activity towards paraquat as shown by cyclic voltammetry and differential pulse voltammetry. Experimental conditions were optimized with respect to sensing paraquat by varying the electrochemical parameters, solution pH, and accumulation time of DNA. Under the optimized conditions, a linear relation exists between the reduction peak current and the concentration of paraquat in the range from 5?×?10?8 mol L?1 to 7?×?10?5 mol L?1, with a detection limit of 3.6?×?10?9 mol L?1. The utility of the method is illustrated by successful analysis of paraquat in spiked real water samples.
Figure
The DNA was electrodeposited onto the CILE under +1.5?V for 1200?s. The electrochemical behaviors of paraquat on the modified electrode had been studied by cyclic voltammetry and differential pulse voltammetry. Five ml phosphate buffer (pH 7.0) solution was added into an electrochemical cell (10?ml) and then paraquat was successfully added into the cell. The differential pulse voltammograms were recorded when swept from ?0.8?V to ?0.3?V. The peak currents at about ?0.63?V for paraquat were measured.  相似文献   

13.
We report on a novel method for visual detection silver(I) ion. It is based on the finding that Ag(I) ions are rapidly reduced by hydroquinone to form a shell of silver on the surface of gold nanoparticles (AuNPs) which act as catalysts for this reaction. This leads to a color change from red to yellow which can be seen with bare eyes. This scheme is sensitive and highly specific for Ag(I) ions. The detection limits are 5 μM for visual inspection and 1 μM for photometric readout, respectively. The method was successfully applied to the determination of Ag(I) ions in spiked lake water and soil.
A novel visual detection method based on the catalysis of gold nanoparticles was developed for the determination of Ag+ in the lake water and soil.  相似文献   

14.
We report on a novel biosensor for determining sequence-specific DNA. It is based on resonance light scattering (RLS) caused by the aggregation of gold bipyramids. These display localized surface plasmon resonance and can be used as a bioprobe. The absorption spectra and the transmission electron micrographs provide visual evidence of the aggregation of the gold bipyramids in the presence of DNA. The RLS intensity of the gold bipyramids increases with the concentration of the target DNA. The method was successfully applied to the determination of a 30-mer single-stranded oligonucleotide and works over the 0.1–10?nM concentration range.
Figure
The electrostatic interaction between the ssDNA and gold bipyramids was the driving force to form gold bipyramid-ssDNA complex. After the target DNA added into the gold bipyramid-ssDNA complex suspension, the hybridization between the target DNA and probe ssDNA happened, which caused the aggregation of gold bipyramids.  相似文献   

15.
We report on the modification of a graphene paste electrode with gold nanoparticles (AuNPs) and a Nafion-L-cysteine composite film, and how this electrode can serve as a platform for the construction of a novel electrochemical immunosensor for the detection of hepatitis B surface antigen (HBsAg). To obtain the immunosensor, an antibody against HBsAg was immobilized on the surface of the electrode, and this process was followed by cyclic voltammetry and electrochemical impedance spectroscopy. The peak currents of a hexacyanoferrate redox system decreased on formation of the antibody-antigen complex on the surface of the electrode. Then increased electrochemical response is thought to result from a combination of beneficial effects including the biocompatibility and large surface area of the AuNPs, the high conductivity of the graphene paste electrode, the synergistic effects of composite film, and the increased quantity of HBsAb adsorbed on the electrode surface. The differential pulse voltammetric responses of the hexacyanoferrate redox pair are proportional to the concentration of HBsAg in the range from 0.5–800?ng?mL?1, and the detection limit is 0.1?ng?mL?1 (at an S/N of 3). The immunosensor is sensitive and stable.
Figure
We report on the modification of a graphene paste electrode with gold nanoparticles and a Nafion-L-cysteine composite film, and how this electrode can serve as a platform for the construction of a novel electrochemical immunosensor for the detection of hepatitis B surface antigen. The immunosensor is sensitive and stable.  相似文献   

16.
A dimeric organophosphorus hydrolase (OPH; EC 3.1.8.1; 72 kDa) was isolated from wild-type bacteria, analyzed for its 16s rRNA sequence, purified, and immobilized on gold nanoparticles (AuNPs) to form the transducer part of a biosensor. The isolated strain was identified as Pseudomonas aeruginosa. The AuNPs were characterized by transmission electron microscopy and localized surface plasmon resonance. Covalent binding of OPH to the AuNPs was confirmed by spectrophotometry, enzymatic activity assays, and FTIR spectroscopy. Coumarin 1, a competitive inhibitor of OPH, was used as a fluorogenic probe. The bioconjugates quench the emission of coumarin 1 upon binding, but the addition of paraoxon results in an enhancement of fluorescence that is directly proportional to the concentration of paraoxon. The gold-OPH conjugates were then used to determine paraoxon in serum samples spiked with varying levels of paraoxon. The method works in the 50 to 1,050 nM concentration range, has a low standard deviation (with a CV of 5.7–11 %), and a detection limit as low as 5?×?10?11 M.
Figure
Coumarin 1, a competitive inhibitor of organophosphorus hydrolase, was used as a fluorogenic probe in the bioconjugates. The gold nanoparticles contained in the bioconjugates quench the emission of coumarin 1 upon binding, but the addition of paraoxon results in an enhancement of fluorescence leading to its detection.  相似文献   

17.
We describe a highly sensitive and selective amperometric sensor for the determination of nitrite. A glassy carbon electrode was modified with a composite made from gold nanoparticles (AuNPs) and sulfonated graphene (SG). The modified electrode displays excellent electrocatalytic activity in terms of nitrite oxidation by giving much higher peak currents (at even lower oxidation overpotential) than those found for the bare electrode, the AuNPs-modified electrode, and the SG-modified electrode. The sensor has a linear response in the 10 μM to 3.96 mM concentration range, a very good detection sensitivity (45.44 μA mM?1), and a lower detection limit of 0.2 μM of nitrite. Most common ions and many environmental organic pollutants do not interfere. The sensor was successfully applied to the determination of nitrite in water samples, and the results were found to be consistent with the values obtained by spectrophotometry.
Figure
A highly sensitive amperometric sensor for nitrite using a glassy carbon electrode modified with gold nanoparticles/sulfonated graphene (AuNPs/SG) composites is presented  相似文献   

18.
We present two colorimetric procedures for the determination of cyanuric acid, using silver nanoparticle-based (AgNPs) probes. The first is making use of melamine-modified AgNPs which bind to cyanuric acid through hydrogen bonding to form a large conjugate network that enhances the aggregation of AgNPs to produce an absorbance peak at 640 nm and a green coloration. In the second assay, melamine is directly added to the sample in order to form a stable complex with cyanuric acid. AgNPs are then added, resulting in the formation of an absorbance peaking at 525 nm and a color change from green (blank sample) to purple or orange-red as a function of cyanuric acid concentration. Matrix effects, that originate from the interaction of alkaline earth metals with the charged surface of the AgNPs, are mitigated through a matrix-matched calibration. In this manner, spectral transitions can be selectively attributed to the concentration of cyanuric acid, which can be even visually quantified at low mg L?1 levels with minimum sample pre-treatment and without sophisticated instrumentation.
Figure
Two colorimetric procedures for the determination of cyanuric acid, using silver nanoparticle-based (AgNPs) probes are presented. Matrix effects, which originate from the interaction of alkaline earth metals with the charged surface of the AgNPs, are mitigated through a matrix-matched calibration. In this manner, spectral transitions can be selectively attributed to the concentration of cyanuric acid, which can be visually quantified at low mg L?1 levels with minimum sample pre-treatment and no sophisticated instrumentation.  相似文献   

19.
We have developed an enzymatic glucose biosensor that is based on a flat platinum electrode which was covered with electrophoretically deposited rhodium (Rh) nanoparticles and then sintered to form a large surface area. The biosensor was obtained by depositing glucose oxidase (GOx), Nafion, and gold nanoparticles (AuNPs) on the Rh electrode. The electrical potential and the fractions of Nafion and GOx were optimized. The resulting biosensor has a very high sensitivity (68.1 μA mM?1 cm?2) and good linearity in the range from 0.05 to 15 mM (r?=?0.989). The limit of detection is as low as 0.03 mM (at an SNR of 3). The glucose biosensor also is quite selective and is not interfered by electroactive substances including ascorbic acid, uric acid and acetaminophen. The lifespan is up to 90 days. It was applied to the determination of glucose in blood serum, and the results compare very well with those obtained with a clinical analyzer.
Figure
An enzymatic glucose biosensor was prepared based on rhodium nanoparticle modified Pt electrode and glucose oxidase immobilized in gold nanoparticles and Nafion composite film. The electrode showed a good response to glucose. The sensor was applied to the determination of glucose in blood serum.  相似文献   

20.
We have immobilized DNA on a glassy carbon electrode (GCE) modified with graphene oxide (GO) to develop an electrochemical biosensor for catechol. Compared to carbon nanotubes, the use of GO dramatically improved the electrooxidative current of the guanine and adenine moieties in DNA but retained the low background current of unmodified GCEs. Factors such as DNA adsorption time, DNA concentration and pH of solution were investigated to optimize experimental conditions. In the presence of catechol, the voltammetric response to DNA was inhibited due to the interaction between DNA and catechol. The response to adenine is linearly proportional to the concentration of catechol in the range from 1.0?×?10?6 to 1.0?×?10?4 mol·L?1. If catechol is degraded by the combined action of UV light and hydrogen peroxide, the response to DNA is restored. Thus, the modified electrode can act as an efficient biosensor for monitoring the degradation of catechol.
Figure
GO dramatically improved the electrooxidative current of the guanine and adenine moieties in DNA but retained the low background current of unmodified GCEs. While the DNA/GO-modified electrode was applied to monitor catechol, it showed sensitive response to catechol before and after photodegradation treatment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号