A new specific stationary phase based on poly(1-allylimidazole)-grafted silica has been synthesized and characterized, by infrared spectra, elemental analysis, thermogravimetric analysis and X-ray photoelectron spectroscopy. The results of test showed that poly(1-allylimidazole) can effectively mask the residual silanol groups and reduce the adverse effect of residual silanol. Using this stationary phase, phenol compounds, aniline compounds, and polycyclic aromatic hydrocarbons were successfully separated with symmetric peak shapes in the reversed-phase chromatography. Inorganic anions (IO3, BrO3, Br, NO3, I, SCN) were also separated completely in the anion-exchange chromatography using sodium chloride solution as the mobile phase. The effects of pH and the concentration of eluent on the separation of inorganic anions were studied. The separation mechanism appears to involve the mixed interactions of hydrogen bonding, hydrophobic, π–π, electrostatic, and anion-exchange interactions.  相似文献   

2.
Li Y  Feng Y  Chen T  Zhang H 《Journal of chromatography. A》2011,1218(35):5987-5994
An imidazoline was prepared by solvent-free microwave-assisted organic synthesis and immobilized on porous silica particles by polymerization. The resulting material was composed of both hydrophobic alkyl ester chains and hydrophilic imidazoline rings, which gave it both hydrophilic interaction and reversed-phase characteristics. The titration curve suggests that the new material has buffering capacity and acquires increasing positive charge over the pH range 9-4, and is "zwitterionic" in the upper part of this pH range. Through investigating the effect of column temperature, the water content, pH and ion strength of mobile phase on the retention time of polar compounds in highly organic eluents, it was found that the new material could be used as a hydrophilic interaction liquid chromatography (HILIC) stationary phase which involved a complex retention process consisting of partitioning, surface adsorption and electrostatic interactions. In addition, the retention behavior of aromatic compounds in different mobile phase conditions was also studied, which showed the new material mainly exhibited a partitioning mechanism in the reversed-phase liquid chromatography (RPLC) mode. The separation of six water-soluble vitamins and five aromatic compounds were achieved by using the new material in the HILIC and RPLC modes, respectively.  相似文献   

3.
Novel pH-responsive polymer-grafted silica was successfully synthesized through the radical "grafting from" polymerization on azo initiator-immobilized silica. The immobilization of azo initiator onto the silica surface was achieved by the reaction of surface amino groups with 4,4'-azobis(4-cyanovaleric acid chloride). The polymer-grafted silica was prepared by stirring suspension of the azo initiator-immobilized silica in anhydrous dioxane containing acrylic acid (AAc) and butyl acrylate (BA). The resulting polymer-grafted silica was demonstrated to be pH responsive to hydrophobic/hydrophilic property by reversed-phase liquid chromatography (RPLC) and hydrophilic interaction chromatography (HILIC). In RPLC mode, the retention of aromatic compounds decreased with the increase in the pH of mobile phase. However, the opposite result was obtained in HILIC mode; the retention of soybean isoflavones was stronger with the mobile phase at higher pH. Finally, the separations of sulfonamides and soybean isoflavones were carried out in RPLC mode and the separation of some nucleotides was achieved in HILIC mode.  相似文献   

4.
A new hydrophilic and nonionic poly(2-vinyloxazoline)-grafted silica (Sil-VOX n ) phase was synthesized and applied for the separation of nucleosides and nucleobases in hydrophilic interaction chromatography (HILIC). Polymerization and immobilization onto silica were confirmed by using characterization techniques including 1H NMR spectroscopy, elemental analysis, and diffuse reflectance infrared Fourier transform spectroscopy. The hydrophilicity or wettability of Sil-VOX n was observed by measuring the contact angle (59.9°). The chromatographic results were compared with those obtained with a conventional HILIC silica column. The Sil-VOX n phase showed much better separation of polar test analytes than the silica column, and the elution order was different. Differences in selectivity between these two columns indicate that the stationary phase cannot function merely as an inert support for a water layer into which the solutes are partitioned from the bulk mobile phase. To elucidate the interaction mechanism, the separation of dihydroxybenzene isomers was performed on both columns in normal-phase liquid chromatography. Sil-VOX n was very sensitive to the dipole moments of the positional isomers of polycyclic aromatic compounds in normal-phase liquid chromatography. The interaction mechanism for Sil-VOX n in HILIC separation is also described.
Figure
Separation of nucleosides and nucleobases with Sil-VOXn (bottom) and a commercial silica column (top). Mobile phase of acetonitrile and 20 mM ammonium acetate (9:1, v/v). Flow rate 1 ml min-1, column temperature 25 °C. The analytes were as follows 5-iodouracil (1), thymine (2), uracil (3), 4,6-diaminopyrimidine (4), uridine (5), adenosine 2 (6), cytosine (7), cytidine (8), and guanosine (9)  相似文献   

5.
A novel cationic hydrophilic interaction monolithic stationary phase based on the copolymerization of 2-(methacryloyloxy)ethyltrimethylammonium methyl sulfate (META) and pentaerythritol triacrylate (PETA) in a binary porogenic solvent consisting of cyclohexanol/ethylene glycol was designed for performing capillary liquid chromatography. While META functioned as both the ion-exchange sites and polar ligand provider, the PETA, a trivinyl monomer, was introduced as cross-linker. The monolithic stationary phases with different properties were easily prepared by adjusting the amount of META in the polymerization solution as well as the composition of the porogenic solvent. The hydrophilicity of the monolith increased with increasing content of META in the polymerization mixture. A typical hydrophilic interaction chromatography mechanism was observed when the content of acetonitrile in the mobile phase was higher than 20%. The poly(META-co-PETA) monolith showed very good selectivity for neutral, basic and acidic polar analytes. For polar-charged analytes, both hydrophilic interaction and electrostatic interaction contributed to their retention. Peak tailing of basic compounds was avoided and the efficient separation of benzoic acid derivatives was obtained.  相似文献   

6.
This work describes the preparation of an anion-exchange phase based on silica, using a two-step modification process. First, 10 microm Davisil silica particles were silanized with chloropropyltrimethoxysilane to yield chloropropyl silica. The modified silica was then reacted with pyridine to produce positively charged propylpyridinium groups on the surface, the anion-exchange sites. The phase was characterized by thermogravimetric analysis and infrared and solid state 13C and 29Si NMR spectroscopies. HPLC separations of common inorganic anions, including chloride, nitrite, bromide and nitrate, were performed using 150 x 3.9 HPLC columns packed with the phase, using a phthalate buffer solution as mobile phase with non-suppressed conductivity detection. Efficiency and resolution were calculated and the results show that the new phase has significant promise for the analysis of these anions in environmental samples.  相似文献   

7.
周行  陈佳  张樱山  赵亮  邱洪灯 《色谱》2020,38(4):438-444
通过表面自由基链转移聚合和亲核取代反应制备了一种新型奎宁功能化聚乙烯咪唑修饰硅胶亲水色谱固定相(Sil-PIm-Qn)。通过元素分析和红外光谱对该固定相进行表征,并在亲水相互作用色谱(HILIC)模式下对其进行了色谱性能评价。结果表明,该固定相对5种氨基酸、9种磺胺以及10种碱基核苷有较好的分离选择性。实验考察了流动相中有机相乙腈体积分数和水相中乙酸铵浓度对待分离物质保留行为的影响,并进一步对固定相分离的重复性进行了考察,其保留时间的相对标准偏差(RSD)为0.08%~2.30%(n=10)。该亲水色谱固定相制备方法简单,并且表现出了优异的亲水色谱分离性能,有望在磺胺类药物及生物样品中碱基核苷等亲水性物质的分离分析中有一定应用。  相似文献   

8.
A new stationary phase demonstrated effective separation towards polar analytes or their counterions within a single run.  相似文献   

9.
10.
In this paper, the preparation of a new anion-exchange phase based on N-methylimidazolium immobilized on silica is described. HPLC separations of common inorganic anions, including an iodate, chloride, bromide, nitrate, iodide, and thiocyanate, were performed using a HPLC column (200 x 4.6mm I.D.) packed with the said phase, and phosphate buffer solution and acetate buffer solution as the mobile phases respectively, with UV detection at 200 nm. The effects of pH and the concentration of the eluent on the separation of anions were studied. With the efficiency and resolution of the column calculated, the results showed that this new phase can be used in the analysis of these in organic anions with great prospects. At the same time, successful separations of some organic anions, amines and nucleotides have also been obtained respectively using this new phase. The phase displayed a main strong anion-exchange mechanism and a coexistent reverse-phase interaction, etc.  相似文献   

11.
12.
Summary Silica beads of 6-μm average diameter were silanized with methylvinyldiethoxysilane and then subjected to encapsulation with poly(methylvinylsiloxane). The resulting product is a new stationary phase for reversed-phase high performance liquid chromatography (RP-HPLC) which has superior ability for the separation of polar, non-polar and basic compounds. The chromatographic peaks are symmetric. Its stability has been studied; after continuous use for three months the carbon content and chromatographic behaviour of the phase were unchanged. on to the silica surface to given an uniform organic film. Material prepared in this way has both good chromatographic behaviour and superior selectivity. Because contact of the silica matrix with the mobile phase is avoided, the alkali-resisting ability of the stationary phase is increased. The non-specific adsorption of alkaline solutes on to the silica surface is also avoided because of the complete coverage of surface silanol groups. Reports of stationary phases encapsulated with polystyrene [6], polybutadiene [I] and octadecylsiloxane polymers have recently appeared in the literature [3]. In this paper we report the encapsulation of poly-(methylvinylsiloxane) (analogous to the phase SE-31 often used in GC) on to a silica matrix previously modified with methylvinyldiethoxysilane. The resulting phase has superior performance in reversed-phase HPLC.  相似文献   

13.
14.
Liu Y  Du Q  Yang B  Zhang F  Chu C  Liang X 《The Analyst》2012,137(7):1624-1628
A silica based amino stationary phase was prepared by immobilization of propargylamine on azide-silica via click chemistry. This readily prepared click amino stationary phase demonstrated good selectivity in separation of common inorganic anions under ion chromatography (IC) mode, and the triazole ring in combination with free amino group was observed to play a major role for separation of the anions examined. On the other hand, the stationary phase also showed good hydrophilic interaction liquid chromatography (HILIC) properties in the separation of polar compounds including nucleosides, organic acids and bases. The retention mechanism was found to match well the typical HILIC retention.  相似文献   

15.
Li Y  Li J  Chen T  Liu X  Zhang H 《Journal of chromatography. A》2011,1218(11):1503-1508
The mixed sulfated/methacryloyl polysaccharide derivative was prepared and successfully immobilized onto the surface of porous silica particles by polymerization. Polysaccharide derivative was calculated as 10.33% in the stationary phase prepared. The new stationary phase (PMSP) showed both hydrophilic interaction (HILIC) and per aqueous liquid chromatography (PALC) characteristics. The effects of column temperature, the water content, pH and ion strength of mobile phase on the retention time of test compounds in highly aqueous eluents were investigated to evaluate the PALC features of PMSP. The column efficiency is about 31,000 plates/m for benzoic acid in water/ACN (97/3, v/v) mobile phase at a flow rate of 1.0 mL/min. Compared with C18 column, the PMSP had shorter retention time for weak polar and non-polar compounds, but also showed stronger retention for strong polar compounds. It indicated that PALC was a suitable mode of chromatography as replacement of HILIC and complementarity of reversed-phase liquid chromatography (RPLC).  相似文献   

16.
周永正  梁鑫淼  钟虹敏 《色谱》2000,18(1):42-45
 较为系统地研究了聚4甲基5乙烯基噻唑键合硅胶固定相(PMVCAphase)与C18,C8及苯基柱在反相色谱中甲醇水体系下的选择性差别。结果表明,该固定相与常用反相色谱固定相有相似性,显示了一般反相色谱固定相填料的特性;另一方面,又由于其特殊结构,更多地显示了其在反相色谱上的特殊选择性。  相似文献   

17.
A new highly hydrophilic stationary phase based on graft polymerization of sorbitol methacrylate from the surface of Kromasil silica particles is described. Polymerization was initiated by thermal cleavage of tert-butyl hydroperoxide covalently attached to the silica particle surface. Due to the highly amphiphilic properties of the monomer, an extensive search was needed to find solvent conditions that enabled surface-initiated polymerization. This was finally solved by using a mixture of solvents that only partially dissolved the monomer. The graft polymerization was confirmed by Fourier transform infrared spectroscopy and elemental analysis. The resulting stationary phase was evaluated by HPLC and exhibited a selectivity markedly different from that of commercially available columns and of neat silica.  相似文献   

18.
19.
A novel stationary phase based on quinolinium ionic liquid-modified silica was prepared and evaluated for high-performance liquid chromatography. The stationary phase was investigated via normal-phase (NP), reversed-phase (RP), and anion-exchange (AE) chromatographic modes, respectively. Polycyclic aromatic hydrocarbons, phthalates, parabens, phenols, anilines, and inorganic anions were used as model analytes in chromatographic separation. Using the newly established column, organic compounds were separated successfully by both NP and RP modes, and inorganic anions were also separated completely by AE mode. The obtained results indicated that the stationary phase could be applied in different chromatographic modes, with multiple-interaction mechanism including van der Waals forces (dipole–dipole, dipole–induced dipole interactions), hydrophobic, ππ stacking, electrostatic forces, hydrogen bonding, anion-exchange interactions, and so on. The column packed with the stationary phase was applied to analyze phthalates and parabens in hexane extracts of plastics. Tap water and bottled water were also analyzed by the column, and nitrate was detected as 20.1 and 13.8 mg L?1, respectively. The results illustrated that the stationary phase was potential in practical applications.
Figure
?  相似文献   

20.
Poly(2-N-carbazolylethyl acrylate) having terminal trimethoxysilyl groups was newly synthesized by radical polymerization and immobilized onto the silica surface (Sil-CEA). The chromatographic property of Sil-CEA was examined by applying polycyclic aromatic hydrocarbons as solutes. Poly(4-vinylpyridine)-modified silica (Sil-VP) and monomeric octadecylated silica (ODS) columns were used as the reference columns. Less sensitivity to molecular hydrophobicity and enhanced molecular planarity selectivity were obtained with Sil-CEA compared to ODS. On the other hand, high retention factors for the analyzed solutes and an opposite elution order for linear and disc-shaped solutes were obtained with Sil-CEA compared with Sil-VP. In this paper, the application for separation of tocopherols was also described.  相似文献   