首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 484 毫秒
1.
Wang H  Xu G  Dong S 《The Analyst》2001,126(7):1095-1099
The electrochemiluminescence (ECL) of tris(2,2'-bipyridine)ruthenium(II) [Ru(bpy)3(2+)] immobilized in poly(p-styrenesulfonate) (PSS)-silica-Triton X-100 composite films was investigated. The cooperative action of PSS, sol-gel and Triton X-100 attached Ru(bpy)3(2+) to the electrode strongly, and the presence of Triton X-100 prevented drying fractures of the sol-gel films during gelation and even on repeated wet-dry cycles. The modified electrode was used for the ECL detection of oxalate, tripropylamine (TPA) and NADH in a flow injection analysis (FIA) system with a newly designed flow cell. The detection scheme exhibited good stability, short response time and high sensitivity. Detection limits were 0.1, 0.1 and 0.5 micromol L(-1) for oxalate. TPA and NADH, respectively, and the linear concentration range extended from 0.001 to 1 mmol L(-1) for the three analytes. Applications of the flow cell in ECL and electrochemical detection, as well as the immobilization of reagents based on the cooperative action, are suggested.  相似文献   

2.
Li J  Huang M  Liu X  Wei H  Xu Y  Xu G  Wang E 《The Analyst》2007,132(7):687-691
The electrochemiluminescence (ECL) of tris(2,2'-bipyridyl)ruthenium(II) [Ru(bpy)(3)(2+)] ion-exchanged in the sulfonic-functionalized MCM-41 silicas was developed with tripropylamine (TPrA) as a co-reactant in a carbon paste electrode (CPE) using a room temperature ionic liquid (IL) as a binder. The sulfonic-functionalized silicas MCM-41 were used for preparing an ECL sensor by the electrostatic interactions between Ru(bpy)(3)(2+) cations and sulfonic acid groups. We used the IL as a binder to construct the CPE (IL-CPE) to replace the traditional binder of the CPE (T-CPE)--silicone oil. The results indicated that the MCM-41-modified IL-CPE had more open structures to allow faster diffusion of Ru(bpy)(3)(2+) and that the ionic liquid also acted as a conducting bridge to connect TPrA with Ru(bpy)(3)(2+) sites immobilized in the electrode, resulting in a higher ECL intensity compared with the MCM-41-modified T-CPE. Herein, the detection limit for TPrA of the MCM-41-modified IL-CPE was 7.2 nM, which was two orders of magnitude lower than that observed at the T-CPE. When this new sensor was used in flow injection analysis (FIA), the MCM-41-modified IL-CPE ECL sensor also showed good reproducibility. Furthermore, the sensor could also be renewed easily by mechanical polishing whenever needed.  相似文献   

3.
Here,we developed a novel electrochemiluminescence resonance energy transfer(ECL-RET) approach between Ru(bpy)_3~(2+) and Au nanorods(NRs) for sensitive determination of H_2O_2.Au NRs were synthesized through silver ion-assisted seed-mediated method which exhibited an obvious absorption peak at about 627 nm.They were modified at glassy carbon electrode(GCE) surface which showed a significant ECL quenching efficiency about 56.5%due to the ECL-RET process.This Au NRs modified electrode was then utilized to measure the concentration of H_2O_2 on the basis of the significant quenching effect of H_2O_2 on Ru(bpy)_3~(2+) ECL.Results demonstrated that the decrement of ECL intensity at Au NRs modified electrode had ~ 6.6-fold enhancement as compared with that at bare electrode.  相似文献   

4.
The facile synthesis of the novel platinum nanoparticles/Eastman AQ55D/ruthenium(II) tris(bipyridine) (PtNPs/AQ/Ru(bpy)3(2+)) colloidal material for ultrasensitive ECL solid-state sensors was reported for the first time. The cation ion-exchanger AQ was used not only to immobilize ECL active species Ru(bpy)3(2+) but also as the dispersant of PtNPs. Colloidal characterization was accomplished by transmission electron microscopy (TEM), X-ray photoelectron spectrum (XPS), and UV-vis spectroscopy. Directly coating the as-prepared colloid on the surface of a glassy carbon electrode produces an electrochemiluminescence (ECL) sensor. The electronic conductivity and electroactivity of PtNPs in composite film made the sensor exhibit faster electron transfer, higher ECL intensity of Ru(bpy)3(2+), and a shorter equilibration time than Ru(bpy)3(2+) immobilized in pure AQ film. Furthermore, it was demonstrated that the combination of PtNPs and permselective cation exchanger made the sensor exhibite excellent ECL behavior and stability and a very low limit of detection (1 x 10(-15) M) of tripropylamine with application prospects in bioanalysis. This method was very simple, effective, and low cost.  相似文献   

5.
This paper reports a novel detection method for DNA hybridization based on the electrochemiluminescence (ECL) of Ru(bpy)(3)(2+) with a DNA-binding intercalator as a reductant of Ru(bpy)(3)(3+). Some ECL-inducible intercalators have been screened in this study using electrochemical methods combined with a chemiluminescent technique. The double-stranded DNA intercalated by doxorubicin, daunorubicin, or 4',6-diamidino-2-phenylindole (DAPI) shows a good ECL with Ru(bpy)(3)(2+) at +1.19 V (versus Ag/AgCl), while the non-intercalated single-stranded DNA does not. In order to stabilize the self-assembled DNA molecules during ECL reaction, we constructed the ECL DNA biosensor separating the ECL working electrode with an immobilized DNA probe. A gold electrode array on a plastic plate was assembled with a thru-hole array where oligonucleotide probes were immobilized in the side wall of thru-hole array. The fabricated ECL DNA biosensor was used to detect several pathogens using ECL technique. A good specificity of single point mutations for hepatitis disease was obtained by using the DAPI-intercalated Ru(bpy)(3)(2+) ECL.  相似文献   

6.
Guo Z  Shen Y  Zhao F  Wang M  Dong S 《The Analyst》2004,129(7):657-663
The electrochemical and electrogenerated chemiluminescence of Ru(bpy)(3)(2+) immobilized in [clay/Ru(bpy)(3)(2+)](n) multilayer films by layer-by-layer assembly were investigated. The stable multilayer films of clay and Ru(bpy)(3)(2+) were assembled by alternate adsorption of negatively charged clay platelets and positively charged Ru(bpy)(3)(2+) from their aqueous dispersions. UV-vis spectroscopy, quartz crystal microbalance (QCM), cyclic voltammetry, and electrogenerated chemiluminescence (ECL) were used to monitor the immobilization of Ru(bpy)(3)(2+) and the regular growth of the [clay/Ru(bpy)(3)(2+)](n) multilayer films. The multilayer films modified electrode was used for the ECL detection of tripropylamine (TPA) and oxalate. The proposed novel immobilized method exhibited good stability, reproducibility and high sensitivity for the determination of TPA and oxalate, which mainly resulted from the contributing of clay nanoparticles with appreciable surface area, special structural features and unusual intercalation properties. Detection limits were 20 and 100 nM for TPA and oxalate, respectively and the linear concentration range extended from 60 nM to 0.66 mM for TPA.  相似文献   

7.
利用静电吸附作用将联吡啶钌[Ru(bpy)32+]负载到巯基化MCM-41介孔二氧化硅纳米颗粒上, 通过金-巯键修饰法将负载后的MCM-41固定在金电极表面, 发展了一种基于MCM-41负载联吡啶钌的电致化学发光传感器, 并研究了其电化学及电致化学发光行为. 基于三聚氰胺与增敏剂三正丙胺氨基结构的相似性, 将负载Ru(bpy)32+的MCM-41电致化学发光传感器用于三聚氰胺的检测, 获得了良好的检测效果, 为检测三聚氰胺提供了一种快速、简便的方法. 同时, 该研究为Ru(bpy)32+在电极表面的固定化提供了新思路.  相似文献   

8.
An electrochemiluminescence (ECL) sensor based on Ru(bpy)32+-graphene-Nafion composite film was developed. The graphene sheet was produced by chemical conversion of graphite, and was characterized by atomic force microscopy (AFM), scanning electron microscopy (SEM), and Raman spectroscopy. The introduction of conductive graphene into Nafion not only greatly facilitates the electron transfer of Ru(bpy)32+, but also dramatically improves the long-term stability of the sensor by inhibiting the migration of Ru(bpy)32+ into the electrochemically inactive hydrophobic region of Nafion. The ECL sensor gives a good linear range over 1 × 10−7 to 1 × 10−4 M with a detection limit of 50 nM towards the determination of tripropylamine (TPA), comparable to that obtained by Nafion-CNT. The ECL sensor keeps over 80% and 85% activity towards 0.1 mM TPA after being stored in air and in 0.1 M pH 7.5 phosphate buffer solution (PBS) for a month, respectively. The long-term stability of the modified electrode is better than electrodes modified with Nafion, Nafion-silica, Nafion-titania, or sol-gel films containing Ru(bpy)32+. Furthermore, the ECL sensor was successfully applied to the selective and sensitive determination of oxalate in urine samples.  相似文献   

9.
The Ru(bpy)_3~(2+) doped graphene oxide-silica composite film(Ru/GO-SiCF) was synthesized by one pot hydrolysis and condensation of tetraethylorthosilicate(TEOS) in the water-alcohol solution of graphene oxide and Ru(bpy)_3~(2+) at room temperature.The prepared Ru/GO-SiCF modified glassy carbon electrode(GCE) showed excellent electrochemiluminescence(ECL) behavior for the determination of tripropylamine(TPA) with high sensitivity and good stability.We expected this simple and novel material will find further application in construction of other targets sensors.  相似文献   

10.
It was found that stannous chloride (SnCl(2)), as a popular inorganic reducing reagent, could obviously enhance the electrochemiluminescence (ECL) of tris(2,2'-bipyridyl) ruthenium(II) (Ru(bpy)(3)(2+)) in aqueous solution. Some factors affecting the ECL reactions between Ru(bpy)(3)(2+) and Sn(2+), including pH, concentrations of coreactant, and electrode materials, were investigated by comparison with a classic ECL coreactant tripropylamine (TPA). The Ru(bpy)(3)(2+)-Sn(2+) ECL coreactant system produces stronger and more stable ECL signals, can keep its excellent ECL activity over a wider pH range and has more choices in using electrode materials than the Ru(bpy)(3)(2+)-TPA ECL coreactant system. The ECL mechanism of the Ru(bpy)(3)(2+)-Sn(2+) coreactant system was also studied in detail.  相似文献   

11.
An electrochemiluminescence (ECL) sensor with good long-term stability and fast response time has been developed. The sensor was based on the immobilization of tris(2,2′-bipyridyl)ruthenium(II) (Ru(bpy)32+) into the Eastman-AQ55D–silica composite thin films on a glassy carbon electrode. The ECL and electrochemistry of Ru(bpy)32+ immobilized in the composite thin films have been investigated, and the modified electrode was used for the ECL detection of oxalate, tripropylamine (TPA) and chlorpromazine (CPZ) in a flow injection analysis system and showed high sensitivity. Because of the strong electrostatic interaction and low hydrophobicity of Eastman-AQ55D, the sensor showed no loss of response over 2 months of dry storage. In use, the electrode showed only a 5% decrease in response over 100 potential cycles. The detection limit was 1 μmol l−1 for oxalate and 0.1 μmol l−1 for both TPA and CPZ (S/N=3), respectively. The linear range extended from 50 μmol l−1 to 5 mmol l−1 for oxalate, from 20 μmol l−1 to 1 mmol l−1 for TPA, and from 1 μmol l−1 to 200 μmol l−1 for CPZ.  相似文献   

12.
Lu X  Liu D  Du J  Wang H  Xue Z  Liu X  Zhou X 《The Analyst》2012,137(3):588-594
The novel phenomenon of cathodic electrochemiluminescence on a gold electrode in tris(bipyridine) ruthenium(II) (Ru(bpy)(3)(2+)) solution is described for the first time. A cathodic electrochemiluminescence (ECL) was found to mainly occur at 0.4-0.8 V with continuous potential scanning from 0.2-1.4 V and the ECL peak was observed around 0.68 V, which was quite different from generally reported Ru(bpy)(3)(2+) ECL. Our group speculated that Ru(bpy)(3)(2+) possibly reacts with the gold electrode in the acidic phosphate buffer solution (PBS) to generate luminescence. The possible ECL mechanism was discussed according to the presented results. Moreover, it is revealed that the Au as co-reactant in the Ru-system contributed dominantly to the whole ECL. Therefore, the reaction between Ru(bpy)(3)(2+) and the newly formed Au implied that the inert metal Au could become a promising material for ECL investigations.  相似文献   

13.
Electrochemical behavior and electrogenerated chemiluminescence (ECL) of tris(2,2′-bipyridyl)ruthenium(II) (Ru(bpy)32+) immobilized in poly(3,4-ethylenedioxythiophene)/poly(styrenesulfonate)-poly(vinyl alcohol) (PEDOT/PSS-PVA) composite films via ion-exchange have been investigated with tripropylamine (TPA) as the co-reactant at a glassy carbon electrode. The immobilized Ru(bpy)32+ performed a surface-controlled electrode reaction. The Ru(bpy)32+ modified electrode showed a fast ECL response to TPA, and was used for the ECL detection of TPA with high sensitivity. The ECL intensity was linearly related to concentrations of TPA over the range from 0.50 μmol L−1 to 0.80 mmol L−1, and the detection limit was 0.10 μmol L−1 (S/N = 3). The as-prepared electrode exhibited good precision and long-term stability for TPA determination.  相似文献   

14.
A novel effective co-reactant for electrogenerated chemiluminescence (ECL) of Ru(bpy)(3)(2+) has been found. Alpha-position-dialkylated thiophene derivatives such as 2,5-dimethylthiophene (DMT) could be used as a co-reactant for Ru(bpy)(3)(2+) ECL. The reaction mechanism of the Ru(bpy)(3)(2+)/DMT system was proposed on the basis of the identification of the reaction product, the relationship between the molecular structure and the chemiluminescent intensity, and the electrochemical study. The obtained reaction mechanism was similar to that of the Ru(bpy)(3)(2+)/aliphatic tertiary amine system. Based on these results, the preliminary studies of the Ru(bpy)(3)(2+) ECL detection system using DMT as a co-reactant were performed. Under the optimal ECL conditions, the plot of ECL intensity versus the concentration of Ru(bpy)(3)(2+) was linear over the concentration range 1.0x10(-8) to 1.5x10(-7) M (determination coefficient=0.9996).  相似文献   

15.
The electrochemiluminescence (ECL) of magnetic microbeads modified with tris(2,2'-bipyridine)ruthenium(II) ([Ru(bpy)3]2+) was studied in the presence of tri-n-propylamine (TPA) to develop highly sensitive ECL detection system, where the employed microbead has a diameter of 4.5 microm. The ECL signal of the [Ru(bpy)3]2+ derivative-modified magnetic microbeads was found to be affected by the geometrical distribution of the magnetic microbeads on the electrode surface. The ECL peak intensity increased with increasing the number of the beads on the electrode surfaces up to 1.6 x 10(6) beads cm(-2), although above 1.6 x 10(6) beads cm(-2), it decreased. The ECL decrease arises from the physical prevention of the ECL from reaching the photomultiplier tube by the excessive beads. The observed peak ECL signal of the [Ru(bpy)3]2+ derivative-modified magnetic microbeads in the presence of NaN3, which serves as a preservative substance, mainly appeared at a potential of +0.90 V vs Ag/AgCl where [Ru(bpy)3]2+ is hardly oxidized, whereas the ECL signal in the absence of NaN3 appeared at a potential of +1.15 V. The presence of NaN3 on the electrode surface retards formation of an oxide layer on the electrode surfaces and promotes TPA oxidation. The ECL response at +0.90 V was mainly attributed to ECL reaction of excited-state [Ru(bpy)3]2+* formed by oxidation of [Ru(bpy)3]+ with TPA radical cation, where the [Ru(bpy)3]+ was generated by reduction of [Ru(bpy)3]2+ with TPA radical.  相似文献   

16.
Bruce D  McCall J  Richter MM 《The Analyst》2002,127(1):125-128
The effects of electron withdrawing and electron donating groups on the electrochemiluminescent (ECL) properties of tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)3(2+) where bpy = 2,2'-pyridine) are reported. The electrochemistry, photophysics and ECL of (bpy)2Ru(DC-bpy)2+, and (bpy)2Ru(DM-bpy)2+ (DC = 4,4'-dicarboxy-2,2'-bipyridine; DM = 4,4'-dimethyl-2,2'-bipyridine) have been studied relative to Ru(bpy)3(2+) in 50:50 (v/v) acetonitrile(CH3CN):H2O (0.1 M KH2PO4), and aqueous solutions. Furthermore, the effects of Triton X-100 (polyethylene glycol tert-octylphenyl ether) on the electrochemical, spectroscopic and ECL properties of these compounds are reported. The anodic oxidation of Ru(bpy)3(2+), (bpy)2Ru(DC-bpy)2+, and (bpy)2Ru(DM-bpy)2+ produces ECL in the presence of tri-n-propylamine (TPrA) in all solvent systems. ECL efficiencies (phi(ecl), photons produced per redox event) of 0.73 and 0.84 for (bpy)2Ru(DC-bpy)2+, and (bpy)2Ru(DM-bpy)2+ were obtained in aqueous buffered solution, using Ru(bpy)3(2+) as a relative standard (phi(ecl) = 1.0). Addition of 0.4 mM Triton X-100 results in a greater than 2-fold increase in ECL efficiences (i.e., 3.8, 2.4 and 2.3 for Ru(bpy)3(2+), (bpy)2Ru(DC-bpy)2+, and (bpy)2Ru(DM-bpy)2+, respectively) using aqueous Ru(bpy)3(2+) containing no surfactant as standard (phi(ecl) = 1.0). ECL efficiencies of 27.4, 16.5 and 26.1 were found in 50:50 (v/v) CH3CN:H2O (0.1 M KH2PO4) for Ru(bpy)3(2+), (bpy)2Ru(DC-bpy)2+, and (bpy)2Ru(DM-bpy)2+, respectively, using aqueous Ru(bpy)3(2+) containing no surfactant as standard (phi(ecl) = 1.0). Detailed studies support adsorption of surfactant on the electrode surface, thus facilitating TPrA and ruthenium oxidation.  相似文献   

17.
A highly sensitive and stable tris(2,2′-bipyridyl)ruthenium(II) (Ru(bpy)32+) electrogenerated chemiluminescence (ECL) sensor was developed based on carbon nanotube (CNT) dispersed in mesoporous composite films of sol-gel titania and perfluorosulfonated ionomer (Nafion). Single-wall (SWCNT) and multi-wall carbon nanotubes (MWCNT) can be easily dispersed in the titania-Nafion composite solution. The hydrophobic CNT in the titania-Nafion composite films coated on a glassy carbon electrode certainly increased the amount of Ru(bpy)32+ immobilized in the ECL sensor by adsorption of Ru(bpy)32+ onto CNT surface, the electrocatalytic activity towards the oxidation of hydrophobic analytes, and the electronic conductivity of the composite films. Therefore, the present ECL sensor based on the CNT-titania-Nafion showed improved ECL sensitivity for tripropylamine (TPA) compared to the ECL sensors based on both titania-Nafion composite films without CNT and pure Nafion films. The present Ru(bpy)32+ ECL sensor based on the MWCNT-titania--Nafion composite gave a linear response (R2 = 0.999) for TPA concentration from 50 nM to 1.0 mM with a remarkable detection limit (S/N = 3) of 10 nM while the ECL sensors based on titania-Nafion composite without MWCNT, pure Nafion films, and MWCNT-Nafion composite gave a detection limit of 0.1 μM, 1 μM, and 50 nM, respectively. The present ECL sensor showed outstanding long-term stability (no signal loss for 4 months).  相似文献   

18.
A novel electrogenerated chemiluminescence (ECL) sensor based on natural clay and ionic liquid was fabricated. Tris(2,2′‐bipyridine)ruthenium(II) (Ru(bpy)32+) was immobilized on natural clay surface through simple adsorption. An ECL sensor was prepared by mixing Ru(bpy)32+‐incorporated clay, graphite powder and an ionic liquid (1‐butyl‐3‐methylimidazolium hexafluorophosphate) as the binder. The electrochemical behavior and ECL of the immobilized Ru(bpy)32+ was investigated. It was observed that the ECL of immobilized Ru(bpy)32+ was activated by the ionic liquid. The proposed ECL sensor showed high sensitivity to tri‐n‐propylamine (TPrA) and the detection limit was found to be 20 pM. In addition, the ECL sensor displayed good stability for TPrA detection and long‐term storage stability.  相似文献   

19.
An electrochemically stable monolayer of tris(2,2'-bipyridyl)ruthenium(II) was obtained for the first time. It was based on the electrostatic attachment of Ru(bpy)(3)(2+) to the benzene sulfonic acid monolayer film, which was covalently bound onto glassy carbon electrode by the electrochemical reduction of diazobenzene sulfonic acid. The surface-confined Ru(bpy)(3)(2+) underwent reversible surface process, and reacted with the coreactant, tripropylamine, to produce electrochemiluminescence. In view of the stability of the electrode, the results strongly suggested that light was emitted from the surface-confined Ru(bpy)(3)(2+), not from the detached Ru(bpy)(3)(2+). The Ru(bpy)(3)(2+) modified electrode was used to the determination of tripropylamine. It showed good linearity in the concentration range from 5 muM to 1 mM with a detection limit of 1 muM (S/N=4). The good stability of the Ru(bpy)(3)(2+) modified electrode also showed that the benzene sulfonic acid monolayer film prepared can be served as an excellent support to construct multilayers.  相似文献   

20.
Guo W  Yuan J  Li B  Du Y  Ying E  Wang E 《The Analyst》2008,133(9):1209-1213
A unique multilabeling at a single-site protocol of the Ru(bpy)(3)(2+) electrochemiluminescence (ECL) system is proposed. Nanoparticles (NPs) were used as assembly substrates to enrich ECL co-reactants of Ru(bpy)(3)(2+) to construct nanoscale-enhanced ECL labels. Two different kinds of NP substrates [including semiconductor NPs (CdTe) and noble metal NPs (gold)] capped with 2-(dimethylamino)ethanethiol (DMAET) [a tertiary amine derivative which is believed to be one of the most efficient of co-reactants of the Ru(bpy)(3)(2+) system] were synthesized through a simple one-pot synthesis method in aqueous media. Although both CdTe and gold NPs realized the enrichment of ECL co-reactants, they presented entirely different ECL performances as nanoscale ECL co-reactants of Ru(bpy)(3)(2+). The different effects of these two NPs on the ECL of Ru(bpy)(3)(2+) were studied. DMAET-capped CdTe NPs showed enormous signal amplification of Ru(bpy)(3)(2+) ECL, whereas DMAET-capped gold NPs showed a slight quenching effect of the ECL signal. DMAET-capped CdTe NPs can be considered to be excellent nanoscale ECL labels of the Ru(bpy)(3)(2+) system, as even a NP solution sample of 10(-18) M was still detectable after an electrostatic self-assembly concentration process. DMAET-capped CdTe NPs were further applied in the construction of aptamer-based biosensing system for proteins and encouraging results were obtained.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号