首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 372 毫秒
1.
We report on the modification of a graphene paste electrode with gold nanoparticles (AuNPs) and a Nafion-L-cysteine composite film, and how this electrode can serve as a platform for the construction of a novel electrochemical immunosensor for the detection of hepatitis B surface antigen (HBsAg). To obtain the immunosensor, an antibody against HBsAg was immobilized on the surface of the electrode, and this process was followed by cyclic voltammetry and electrochemical impedance spectroscopy. The peak currents of a hexacyanoferrate redox system decreased on formation of the antibody-antigen complex on the surface of the electrode. Then increased electrochemical response is thought to result from a combination of beneficial effects including the biocompatibility and large surface area of the AuNPs, the high conductivity of the graphene paste electrode, the synergistic effects of composite film, and the increased quantity of HBsAb adsorbed on the electrode surface. The differential pulse voltammetric responses of the hexacyanoferrate redox pair are proportional to the concentration of HBsAg in the range from 0.5–800?ng?mL?1, and the detection limit is 0.1?ng?mL?1 (at an S/N of 3). The immunosensor is sensitive and stable.
Figure
We report on the modification of a graphene paste electrode with gold nanoparticles and a Nafion-L-cysteine composite film, and how this electrode can serve as a platform for the construction of a novel electrochemical immunosensor for the detection of hepatitis B surface antigen. The immunosensor is sensitive and stable.  相似文献   

2.
A disposable electrochemical myeloperoxidase (MPO) immunosensor was fabricated based on the indium tin oxide electrode modified with a film composed of gold nanoparticles (AuNPs), poly(o-phenylenediamine), multi-walled carbon nanotubes and an ionic liquid. The composite film on the surface of the electrode was prepared by in situ electropolymerization using the ionic liquid as a supporting electrolyte. Negatively charged AuNPs were then adsorbed on the modified electrode via amine-gold affinity and to immobilize MPO antibody. Finally, bovine serum albumin was employed to block possible remaining active sites on the AuNPs. The modification of the electrode was studied by cyclic voltammetry and scanning electron microscopy. The factors affecting the performance of the immunosensor were investigated in detail using the hexacyanoferrate redox system. The sensor exhibited good response to MPO over two linear ranges (from 0.2 to 23.4 and from 23.4 to 300 ng.mL?1), with a detection limit of 0.05 ng.mL?1 (at an S/N of 3).
Figure
A disposable electrochemical immunosensor for myeloperoxidase based on the indium tin oxide electrode modified with an ionic liquid composite film composed of gold nanoparticles, poly(o-phenylenediamine) and carbon nanotubes.  相似文献   

3.
We describe here the preparation of carbon-coated Fe3O4 magnetic nanoparticles that were further fabricated into multifunctional core/shell nanoparticles (Fe3O4@C@CNCs) through a layer-by-layer self-assembly process of carbon nanocrystals (CNCs). The nanoparticles were applied in a photoluminescence (PL) immunosensor to detect the carcinoembryonic antigen (CEA), and CEA primary antibody was immobilized onto the surface of the nanoparticles. In addition, CEA secondary antibody and glucose oxidase were covalently bonded to silica nanoparticles. After stepwise immunoreactions, the immunoreagent was injected into the PL cell using a flow-injection PL system. When glucose was injected, hydrogen peroxide was obtained because of glucose oxidase catalysis and quenched the PL of the Fe3O4@C@CNC nanoparticles. The here proposed PL immunosensor allowed us to determine CEA concentrations in the 0.005–50 ng?·?mL-1 concentration range, with a detection limit of 1.8 pg?·?mL-1.
Figure
The Fe3O4@C@CNC was prepared and applied in a CEA immunosensor with the help of a flow-injection photoluminescence system.  相似文献   

4.
An immunosensor was prepared for the determination of carcinoembryonic antigen (CEA). It is based on the use of multiwalled carbon nanotubes (MWCNTs) along with horseradish peroxidase-labeled antibody. The enzyme was assembled onto MWCNTs templates using the layer-by-layer technique and then conjugated to carcinoembryonic secondary antibodies (Ab2) as the enzyme label. The resulting assembly results in a largely amplified sensitivity. The response is linear in the range of 0.05 to 45?ng?mL-1, with a detection limit of 16.0?pg?mL-1. The immunosensor possesses good stability and good reproducibility.
Figure
A new immunosensor with double-layer enzyme-modified carbon nanotubes as label for sandwich-type tumor markers was proposed in this study  相似文献   

5.
An amperometric immunosensor has been developed for sensitive determination of hepatitis B surface antigen as a model protein. A glassy carbon electrode was modified with an assembly of positively charged poly(allylamine)-branched ferrocene (PAA-Fc) and negatively charged gold nanoparticles (Au NPs). The formation of PAA-Fc effectively avoids the leakage of Fc, retains its electrochemical activity, and enhances the conductivity of the composite. The adsorption of Au NPs onto the PAA-Fc matrix provides sites for the immobilization of the antigen and a favorable micro-environment to maintain its activity. The morphologies and electrochemistry of the sensing film were investigated via scanning electron microscopy, electrochemical impedance spectroscopy, and cyclic voltammetry. Factors influencing the performance of the immunosensor were studied in detail. The concentration of the antigen can be quantitated (by measuring the decrease of the amperometric response resulting from the specific binding between antigen and antibody) in the range between 0.1 and 150?ng?mL?C1, with a detection limit of 40?pg?mL?C1 (S/N = 3). The method is economical, efficient, and potentially attractive for clinical immunoassays.
Figure
A novel and sensitive amperometric immunosensor based on the assembly of biocompatible positively charged poly(allylamine)-branched ferrocene and negatively charged Au nanoparticles onto a glassy carbon electrode has been developed for sensitive determination of hepatitis B surface antigen as a model protein.  相似文献   

6.
We describe a sensitive electrochemical immunosensor for the detection of deoxynivalenol (DON). It is based on a glassy carbon electrode modified with a composite made from fullerene (C60), ferrocene and the ionic liquid. The components were immobilized on the surface of the electrode using chitosan cross-linked with epichlorohydrin. Then, the antibody to DON was covalently conjugated to the surface which then was blocked with serum albumin. The performance of the immunosensor was investigated by cyclic voltammetry and electrochemical impedance spectroscopy. It offers good repeatability (RSD?=?1.2%), selectivity, a stability of more than 180?days, an impedimetric response to DON in the range of 1?pgmL?1 to 0.3?ng?mL?1, and a detection limit (at S/N?=?3) of 0.3?pgmL?1. The limit of detection is better than that of GC, HPLC, GC-MS, HPLC-MS and LC-MS-MS. The effects of omitting C60 or the ionic liquid were also examined. The results indicate that the sensitivity of the biosensor is 2-fold better if C60 and ionic liquids are used. This demonstrates that C60 facilitates electron transfer on the surface of the modified electrode due to its unique electrochemical properties, while the ionic liquid provides a biocompatible microenvironment for the antibody. This results in increased sensitivity and stability. The method was satisfactorily applied to the determination of DON in food samples.
Figure
Fullerene, ferrocene, chitosan and ionic liquid offer remarkable synergistic contributions towards improve electrochemical performance of DON sensor. This results that novel sensor exhibits a good repeatability (RSD=1.2%), selectivity, very low detection limit (S/N=3) of 0.0003 ng mL-1, an impedimetric response to DON in the range from 0.001 ng mL-1 to 0.3 ng mL-1 and a stability of more than 180 days. Cyclic voltammograms of, Ab/C60-FC-IL-GCE a and Ab/FC-IL-GCE b  相似文献   

7.
We have modified a glassy carbon electrode (GCE) with a film of poly(3-thiophene boronic acid), gold nanoparticles and graphene, and an antibody (Ab) was immobilized on its surface through the covalent bond formed between the boronic acid group and the glycosyl groups of the Ab. Subgroup J of avian leukosis viruses (ALV-J) were electrochemically determined with the help of this electrode. There is a linear relationship between the electron transfer resistance (R et) and the concentration of ALV-J in the range from 527 to 3,162 TCID50?mL?1 (where TCID50 is the 50?% tissue culture infective dose). The detection limit is 210 TCID50?mL?1 (at an S/N of 3), and the correlation coefficient (R) is 0.9964. The electrochemical immunoassay showed good selectivity, stability and reproducibility.
Figure
Schematic illustration of the stepwise immunosensor fabrication process  相似文献   

8.
We report on a new kind of electrochemical immunosensors for simultaneous determination of the biomarkers carcinoembryonic antigen (CEA) and alpha-fetoprotein (AFP). Thionine and ferrocene were applied as distinguishable electrochemical tags (and mediators) which were covalently conjugated on anti-AFP and anti-CEA antibodies, respectively, via carboxy groups. The resulting conjugates were co-immobilized on a glassy carbon electrode functionalized with gold nanoparticles. Finally, horseradish peroxidase (HRP) was immobilized onto the modified electrode. Labeled thionine and ferrocene, respectively, act as distinguishable tags for simultaneous determination of AFP and CEA due to the difference in the location of their voltammetric peaks. With a one-step immunoassay format, the analytes in the sample produced transparent immunoaffinity reaction with the corresponding antibodies on the electrode. Once the immunocomplex is formed, it partially inhibits the active center of the immobilized HRP, and this decreased the activity of HRP in terms of reduction of hydrogen peroxide. This immunosensor enables the simultaneous determination of AFP and CEA in a single run and within the same dynamic range (0.01–50?ng?mL?1) and the same lower detection limit (0.01?ng?mL?1). The reproducibility and stability of the immunosensors are acceptable. The dual immunosensor was applied to evaluate several specimens, and the assay results are in acceptable agreement with clinical data.
Figure
This contribution devises a novel multiplexed electrochemical immunoassay for simultaneous detection of alpha-fetoprotein and carcinoembryonic antigen by using thionine and ferrocene as distinguishable signal tags on a one-spot immunosensor. The assay was performed by using one-step immunoreaction between the immobilized antibodies and the analytes. Although the linear range is relatively narrow, it completely meets the requirement of clinical diagnosis.  相似文献   

9.
We report on a novel electrochemiluminescent (ECL) immunoassay for the ultrasensitive determination of morphine by making use of a gold electrode which was modified with a nanocomposite film containing self-assembled polyamidoamine (PAMAM) CdS quantum dots and electrodeposited gold nanoparticles (Au-NPs). The highly uniform and well-dispersed quantum dots were capped with PAMAM dendrimers. Due to the synergistic effect of the modified quantum dots and the electrodeposited Au-NPs, the ECL response is dramatically enhanced. Under optimal experimental conditions, the immunoreaction between morphine and anti-morphine antibody resulted in a decrease of the ECL signal because of steric hindrance. The calibration plot is linear in the morphine concentration range from 0.2 to 180 ng?mL?1, with a detection limit as low as 67 pg?mL?1. The sensor was successfully applied to the determination of morphine in blood plasma. This kind of assay is expected to pave new avenues in label-free drug assays.
Figure
?  相似文献   

10.
Homogeneous immunoassays using (red) gold nanoparticles represent an attractive detection scheme because of the option of photometric readout. We have applied oriented immobilization of hen egg immunoglobulin Y (IgY) on gold nanoparticles when developing a homogeneous immunoassay for human IgG. In oriented immobilization, as opposed to random immobilization, the antigen binding capabilities of the antibodies are retained. It is shown that such immunoassay has significantly better sensitivity in comparison with methods based on conventional immobilization of affinity-purified antibodies. It is also shown that hen egg IgY is better suited than rabbit antibodies, because much more antibody can be immobilized on gold nanoparticles without any destabilization, probably because of the more acidic nature of these antibodies. In addition, hen egg IgY can be supplied in higher quantity and can be prepared more easily than IgG from rabbits. Bleeding and slaughtering of animals is not needed. The assay presented here has a wide detection range (30–500?ng?.mL?1) and a limit of detection as low as 30?ng.mL?1 of human IgG.
Figure
Nanoparticles are treated by thiol for formation of monolayer with exposed NH2 groups. IgY molecule is oxidized by periodate for formation of aldehyde group in Fc fragment. Consequent addition of such antibodies to gold nanoparticles results in binding of IgY molecules to gold nanoparticles via Fc fragment providing oriented immobilization.  相似文献   

11.
The hepatotoxic microcystins, especially microcystin?CLR (MC?CLR), are causing serious problems to public health and fisheries. We describe here a label-free amperometric immunosensor for rapid determination of MC?CLR in water sample. The sensor was prepared by immobilizing antibody on a gold electrode coated with L-cysteine-modified gold nanoparticles. The stepwise self-assembly of the immunosensor was monitored and characterized by means of electrochemical impedance spectroscopy and differential pulse voltammetry. A 0.60?mmol L?1 solution of hydroquinone was used as the electron mediator. The immunosensor was incubated with MC?CLR at 25?°C for 20?min, upon which the differential pulse voltammetric current changed linearly over the concentration range from 0.05 to 15.00???g L?1, with a detection limit of 20?ng L?1. The developed biosensor was used to determine MC?CLR in spiked crude algae samples. The recovery was in the range from 95.6 to 105%. This method is simple, economical and efficient, this making it potentially suitable for field analysis of MC-LR in crude algae and water samples.
Figure
The present investigation combines SAM monolayer with gold nanoparticles monolayer to prepare a stable film to immobilize the antibody, and takes hydroquinone as electron mediator, establishes a miniature, economic, compatible and label-free amperometric immunosensor for the quick detection of MC-LR.  相似文献   

12.
We have modified a glassy carbon electrode by single-step electrodeposition of graphene (GR), gold nanoparticles (AgNPs), and chitosan (CS) directly from a solution containing graphene oxide, tetrachloroauric acid, and chitosan. The surface and electrochemical properties of the film-modified electrode were investigated by SEM and TEM images. The AuNPs have a diameter of about 20 nm and are uniformly dispersed in the matrix. Combining the advantages of GR (i.e., high surface area and conductivity), of AuNPs (excellent electrical conductivity) and CS (excellent film-forming ability and good water permeability), the hybrid film effectively enhances electron-transfer and promotes the response to lead(II) ion. Under the optimum conditions, a linear relationship exists between electrical current and the concentration of lead (II) ion in the range between 0.5 to 100 μg?L-1, with a detection limit of 1 ng?L-1 (at an SNR of 3). The electrode was successfully applied to the detection of lead(II) in spiked samples of river water.
Figure
Graphene–Au nanoparticles–chitosan (GR–AuNPs–CS) was fabricated by one-step electrodeposition. The obtained GR–AuNPs–CS hybrid was used for trace analysis of the lead (II).  相似文献   

13.
We report on a biosensor for organophosphate pesticides (OPs) by exploiting their inhibitory effect on the activity of acetylcholinesterase (AChE). A boron-doped diamond (BDD) electrode was modified with a nanocomposite prepared from carbon spheres (CSs; with an average diameter of 500 nm) that were synthesized from resorcinol and formaldehyde, and then were coated with gold nanoparticles (AuNPs) by chemically growing them of the CSs. Compared to a bare BDD electrode, the electron transfer resistance is lower on this new electrode. Compared to an electrode without Au-NPs, the peak potential is negatively shifted by 42 mV, and the peak current is increased by 55 %. This is ascribed to the larger surface in the AuNP-CS nanocomposite which improves the adsorption of AChE, enhances its activity, and facilitates electrocatalysis. Under optimum conditions, the inhibitory effect of chlorpyrifos is linearly related to the negative log of its concentration in the 10?11 to 10?7 M range, with a detection limit of 1.3?×?10?13 M. For methyl parathion, the inhibition effect is linear in the 10?12 to 10?6 M range, and the detection limit is 4.9?×?10?13 M. The biosensor exhibits good precision and acceptable operational and temporal stability.
Figure
A novel acetylcholinesterase-based biosensor based on a boron-doped diamond electrode modified with gold nanoparticles and carbon spheres was firstly prepared to detect organophosphate pesticides. This biosensor exhibited higher sensitivity, lower detection limit, good reproducibility and acceptable stability.  相似文献   

14.
We described a sensitive, label-free electrochemical immunosensor for the detection of carcinoembryonic antigen. It is based on the use of a glassy carbon electrode (GCE) modified with a multi-layer films made from Prussian Blue (PB), graphene and carbon nanotubes by electrodeposition and assembling techniques. Gold nanoparticles were electrostatically absorbed on the surface of the film and used for the immobilization of antibody, while PB acts as signaling molecule. The stepwise assembly process was investigated by differential pulse voltammetry and scanning electron microscopy. It is found that the formation of antibody-antigen complexes partially inhibits the electron transfer of PB and decreased its peak current. Under the optimal conditions, the decrease of intensity of the peak current of PB is linearly related to the concentration of carcinoembryonic antigen in two ranges (0.2–1.0, and 1.0–40.0 ng·mL?1), with a detection limit of 60 pg·mL?1 (S/N?=?3). The immunosensor was applied to analyze five clinical samples, and the results obtained were in agreement with clinical data. In addition, the immunosensor exhibited good precision, acceptable stability and reproducibility.
Figure
We described a sensitive electrochemical immunosensor for the detection of the carcinoembryonic antigen. It was based on the use of a glassy carbon electrode modified with a multi-layer films made from Prussian blue, graphene, and carbon nanotubes by electrodeposition and assembling techniques. The immunosensor exhibited good precision and acceptable stability and has been applied to analyze clinical sample with a satisfactory result.  相似文献   

15.
We report on an ultrasensitive fluorescence immunoassay for human chorionic gonadotrophin antigen (hCG). It is based on the use of silica nanoparticles coated with a copolymer (prepared from a fluorene, a phenylenediamine, and divinylbenzene; PF@SiO2) that acts as a fluorescent label for the secondary monoclonal antibody to β-hCG antigen. In parallel, Fe3O4 nanoparticles were coated with polyaniline, and these magnetic particles (Fe3O4@PANI) served as a solid support for the primary monoclonal antibody to β-hCG antigen. The PF@SiO2 exhibited strong fluorescence and good dispersibility in water. A fluorescence sandwich immunoassay was developed that enables hCG concentrations to be determined in the 0.01–100 ng·mL?1 concentration range, with a detection limit of 3 pg·mL?1.
Figure
Fluorescence detection of prepared immune reagent nano-composites using the fluorescence cell  相似文献   

16.
We have modified gold nanoparticles (AuNPs) with triazole acetamide to obtain a material for the sensitive and selective colorimetric determination of iodide. The functionalized AuNPs were prepared by a reductive single chemical step using a Cu(I)-catalyzed click reaction. The presence of iodide ions induces the aggregation of these AuNPs and results in a color change from wine-red to purple. The iodide-induced aggregation can be detected visually with bare eyes, but also by photometry. The detection limit is as low as 15 nM. The method displays excellent selectivity for iodide over other anions due to the selective interaction with the amido groups of the triazole. The method was applied to the determination of iodide in spiked lake waters.
Figure
New triazole acetamide functionalized gold nanoparticles (ATTP-AuNPs) for sensitive and selective colorimetric detection of I? were developed. ATTP-AuNPs showed excellent selectivity toward I? due to the interaction between the amide groups of ATTP and I?.  相似文献   

17.
We report on a new enzyme-free electrochemical immunoassay for the sensitive detection of the p53 protein (p53; a model analyte) by using a screen-printed carbon electrode modified with monoclonal mouse anti-human p53 antibody tagged with gold nanoparticles. First, nanogold microspheres doped with Prussian Blue were synthesized by a reverse micelle method. The resulting microspheres were used to label polyclonal anti-p53 antibody which then was applied in a sandwich immunoassay in pH 6.5 buffer solution using the Prussian Blue in the particles as the redox-active reporter. The electrochemical signal of the immunosensor is shown to increase with the concentration of the analyte (p53 protein) in the range from 0.5 to 80 U mL?1, with a detection limit of 0.1 U mL?1. No non-specific adsorption was observed. Coefficients of variation for intra-assay and inter-assay were below 8.5 % and 11.5 %, respectively. In addition, the method was applied to the analysis of 15 human serum samples, and a good relationship was found between the new immunoassay and the referenced electro-chemiluminescence method.
Figure
?  相似文献   

18.
We describe a label-free electrochemical immunosensor for the carcinoembryonic antigen (CEA). It is based on a nanocomposite consisting of electrochemically reduced graphene oxide, gold nanoparticles (AuNPs), and poly(indole-6-carboxylic acid). Coupled to nanoparticle-amplification techniques and modified with ionic liquid (IL), this immunoassay shows high sensitivity and good selectivity for CEA. At the best working voltage of 0.95 V (vs. Ag/AgCl), the lower detection limit is 0.02 ng·mL?1, and the response to CEA is linear in the range from 0.02 to 90 ng·mL?1. The method was applied to the determination of CEA in spiked serum samples and gave recoveries in the range from 98.5 % to 102 %.
Graphical abstract A label-free electrochemical immunosensor was fabricated for the carcinoembryonic antigen (CEA) with a detection limit of 0.02 ng·mL?1. It is based on a nanocomposite consisting of electrochemically reduced graphene oxide (erGO), gold nanoparticles (Au NP), and poly(indole-6-carboxylic acid) (PICA).
  相似文献   

19.
A novel glucose biosensor is presented as that based on a glassy carbon electrode modified with hollow gold nanoparticles (HGNs) and glucose oxidase. The sensor exhibits a better differential pulse voltammetric response towards glucose than the one based on conventional gold nanoparticles of the same size. This is attributed to the good biological conductivity and biocompatibility of HGNs. Under the optimal conditions, the sensor displays a linear range from 2.0?×?10?6 to 4.6?×?10?5?M of glucose, with a detection limit of 1.6?×?10?6?M (S/N?=?3). Good reproducibility, stability and no interference make this biosensor applicable to the determination of glucose in samples such as sports drinks.
Figure
A novel glucose biosensor was prepared based on glucose oxidase, hollow gold nanoparticles and chitosan modified glassy carbon electrode. The electrode showed a good response for the glucose. The sensor has been verified by the determination of glucose in sport drink  相似文献   

20.
Xiaoyu Cao 《Mikrochimica acta》2014,181(9-10):1133-1141
We have developed an ultra-sensitive electrochemical DNA biosensor by assembling probe ssDNA on a glassy carbon electrode modified with a composite made from molybdenum disulfide, graphene, chitosan and gold nanoparticles. A thiol-tagged DNA strand coupled to horseradish peroxidase conjugated to AuNP served as a tracer. The nanocomposite on the surface acts as relatively good electrical conductor for accelerating the electron transfer, while the enzyme tagged gold nanoparticles provide signal amplification. Hybridization with the target DNA was studied by measuring the electrochemical signal response of horseradish peroxidase using differential pulse voltammetry. The calibration plot is linear in the 5.0?×?10?14 and 5.0?×?10?9 M concentration range, and the limit of detection is 2.2?×?10?15 M. The biosensor displays high selectivity and can differentiate between single-base mismatched and three-base mismatched sequences of DNA. The approach is deemed to provide a sensitive and reliable tool for highly specific detection of DNA.
Figure
We have developed an ultra-sensitive electrochemical DNA biosensor by assembling probe (ssDNA) on a glassy carbon electrode modified with a composite made from molybdenum disulfide, graphene, chitosan and gold nanoparticles. The nanocomposite on the surface acts as relatively good electrical conductor for accelerating the electron transfer, while the enzyme tagged gold nanoparticles provide signal amplification. The biosensor displays high selectivity and can differentiate between single-base mismatched and three-base mismatched sequences of DNA  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号