首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 24 毫秒
1.
Summary The 1:1 complex between titanium (IV) and 5-Br-PADAP can be used to determine titanium by adsorption voltammetry at a stationary Hg-electrode. The experimental conditions for the determination are described. The detection limit is 3×10–10 mol/l Ti (0.015 ppb). Calibration curves are linear for solutions containing 4×10–10 to 5×10–8 mol/l Ti(IV) and an enrichment time of 3 min. The influence of foreign ions was investigated. The determination can be carried out in the presence of a 5000-fold excess of iron.  相似文献   

2.
A method is proposed for the separation of antimony(III) (100–400 g) from bismuth(III), lead(II), gallium(III), thallium(III), tellurium(IV) and tin(IV) from an aqueous solution of pH 0.5–1.5 using 8×10–3–1×10–2 mol dm–3 cyanex 302 dissolved in toluene as an extractant. The antimony is stripped from the cyanex phase with water and determined spectrophotometrically with iodide. Various experimental parameters are optimized and the probable 13 stoichiometry of the extracted species is evaluated. The method is applicable to the analysis of alloys and pharmaceutical samples. The separation and determination take only 20 min.  相似文献   

3.
In the present paper, a simple and sensitive method is proposed for vanadium(IV) determination in the presence of vanadium(V). This is based on the oxidation of vanadium(IV) present in the sample to vanadium(V) by addition of iron(III) cation, followed by a complexation reaction of iron(II) with the spectrophotometric reagent 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (Br-PADAP). The iron(II) reacts with Br-PADAP immediately, forming a stable complex with a large molar absorptivity. The vanadium(IV) determination is possible, with a calibration sensitivity of 0.549 g ml–1, for an analytical curve of 18.8 ng ml–1 to 2.40 g ml–1, molar absorptivity of 2.80 × 104 1 mole–1 cm–1 and a detection limit of 5.5 ng ml–1. Selectivity was increased with the use of EDTA as a masking agent. The proposed method was applied for the vanadium(IV) determination in the presence of several amounts of vanadium(V). The results revealed that 200 g of vanadium(V) do not interfere with determination of 5.00 g of vanadium(IV). The precision and the accuracy obtained were satisfactory (R. S. D.<2%).  相似文献   

4.
Summary Accumulation voltammetry of copper(II) was investigated with a carbon-paste electrode containing salicylideneamino-2-thiophenol(SATP). Copper(II) was accumulated as the copper(II)-SATP complex on the electrode without an applied potential by immersing the electrode in 0.01 mol/l acetate buffer (pH 3.8) containing copper(II). The reduction peak of the copper(II)-SATP complex was observed at –0.12 V (vs. SCE) in 0.01 mol/l acetate buffer (pH 3.8) by scanning the potential in a negative direction. The calibration curve for copper(II) was linear in the range of 2×10–9–1×10–7 mol/l. Since the accumulation of copper(II) is based on a chemical reaction between copper(II) and SATP, copper(II) was selectively accumulated on the electrode. The presented method was applied to the determination of copper(II) in standard reference materials prepared by the National Institute for Environmental Studies.  相似文献   

5.
Summary The cathodic stripping voltammetry of copper(II) was investigated with a method, based on the adsorptive accumulation of the Cu(II)-salicylideneamino-2-thiophenol (SATP) complex on a hanging mercury drop electrode. The copper(II)-SATP complex could be accumulated on the electrode at –0.20 V in 0.01 mol/l nitric acid. The reduction peak of the copper complex was observed by scanning the potential in a negative direction in the differential pulse mode. The calibration curve for copper was linear over the range 5×10–9–1×10–7 mol/l. This method was applied to determine copper(II) in GSJ (Geological Survey of Japan) standard rock reference materials.  相似文献   

6.
A rapid and sensitive spectrophotometric method for the simultaneous determination of sodium dodecyl sulphate (SDS) and sodium linear-dodecylbenzenesulphonate (DBS) with 1-stearyl-4-(4-aminonaphthylazo)-pyridinium bromide (SAPB) is described using the difference at the maximum absorption wavelength of the SDS- and the DBS-ion associate. SDS and DBS have been determined independently by measuring their respective absorbances at the maximum absorption wavelength. The apparent molar absorptivities of the SDS- and the DBS-ion associate are 8.0×104 l mol–1 cm–1 at 445 nm and 4.5×104 l mol–1 cm–1 at 424 nm, respectively. The calibration graph for SDS is linear in the range from 0.1 to 1.0×10–6 mol/l in the presence of 1.2×10–6 mol/l DBS and for DBS from 0.8 to 2.0×10–6 mol/l in the presence of 8.0×10–7 mol/l SDS. The relative standard deviation (n=15) for 8.0×10–7 mol/l SDS is 3.4% and for 1.6×10–6 mol/l DBS 2.1%. The proposed method has been applied to the simulatenous determination of SDS and DBS in river water samples.  相似文献   

7.
Summary The Co(II), Ni(II), Fe(III) and V(IV) complexes of tetraphenylporphine (TPP) can be eluted at short retention times from a LiChrosorb RP-18 column with pure ethanol. However, both Mn(III) and Co(III) complexes of metal TPP chloride type are so strongly retained on the column that they cannot be eluted. While the retention of other metal teraphenylporphine complexes was not affected, that of the metal(III) complexes of the TPP chloride type especially MnTPPCl and CoTPPCl, decreases dramatically with an increase in the concentration of NH4Cl added into the mobile phase; a linear relationship between logk' and log[NH4Cl], with the slope of about–1, has been observed for these two metal(III) complexes in the NH4Cl concentration range from 2.5×10–4 to 1.3×10–2 mol/l. Thus, the specific control of the retention of the metal(III) complexes is enabled by conditioning the NH4Cl content of the mobile phase, and the chromatographic separation is demonstrated.  相似文献   

8.
A sensitive procedure for spectrophotometric determination of cerium(III) has been developed. AtpH 10.2 cerium reacts with 1-(2-pyridylazo)-2-naphthol in 40% ethanol to form a red complex which has an absorption maximum at 545 nm. The molar absorptivity at 545 is 3.95·103 mol–1. Maximum stability of the complex was attained in pure ethanol. The stoichiometries and structures of the chelates were studied applying conductometric titration, visible spectrophotometry and IR spectrophotometry. The IR spectra revealed that coordination takes place through the N=N, C-OH and pyridyl group.
Spektrophotometrische Untersuchungen und analytische Anwendung von Ce(III)-Chelaten mit 1-(2-Pyridylazo)-2-naphthol (PAN)
Zusammenfassung Es wurde eine empfindliche Methode zur spektrophotometrischen Bestimmung von Cer(III) entwickelt. Bei einempH von 10,2 reagiert Cer mit 1-(2-Pyridylazo)-2-naphthol in 40% Ethanol unter Bildung eines roten Komplexes mit einem Absorptionsmaximum bei 545 nm (=3 950). Der Komplex besitzt in reinem Ethanol ein Maximum an Stabilität. Die Stöchiometrien und Strukturen der gebildeten 1:1- und 1:2-Chelate wurden mittels konduktometrischer Titration, Elektronen- und IR-Spektrometrie untersucht. Die IR-Daten zeigen, daß die Koordination über N=N, C-OH und Pyridyl erfolgt.
  相似文献   

9.
Summary The sulfur(IV) catalyzed oxidation of cobalt(II) by dissolved oxygen in azide containing medium has been investigated with respect to its analytical potentialities. The strong absorptivity at 365 nm of the cobalt(III)/azide-complex formed makes possible the establishment of a simple and fast spectrophotometric method for sulfite determinations in aqueous solution. With manganese(II) as an activator and 5 cm cuvettes for absorption measurements the working range is between 5×10–7 and 5×10–5 mol/l sulfite. The new method has been successfully applied to the investigation of rain water samples. Of the potential interferences only those originating from iron(III) and formaldehyde are of practical relevance. The first one can be avoided by proper blank correction, the second by a slight modification of the procedure.
Untersuchung der durch Schwefel(IV) katalysierten Autoxidation von Cobalt(II) in azidhaltiger Lösung im Hinblick auf ihre Anwendung zur Bestimmung von Sulfit in NiederschlÄgen

Dedicated to Prof. Dr. W. Fresenius on the occasion of his 75th birthday  相似文献   

10.
A flow injection method using 2-(5-nitro-2-pyridylazo)-5-(N-propyl-N-sulfopropylamino)phenol-(Nitro-PAPS) as a new chromogenic reagent is presented for sensitive and rapid determination of vanadium. Nitro-PAPS reacts with vanadium(V) in weakly acidic medium to form a water soluble complex of molar absorptivity of 8.0 × 104L mol–1 cm–1 at 592 nm (maximum absorption wavelength), which permits the straightforward application of a flow injection system to the sensitive determination of vanadium. Under the optimum conditions established, a linear calibration graph was obtained in the range 1–120 ng mL–1. The relative standard deviation for 60 ng mL–1 vanadium was 2.2% (n = 5) and the limit of detection was 1 ng mL–1. The sample throughput is about 40 h–1. Most inorganic and organic anions examined did not interfere even at concentrations of 3000–6000 times of vanadium. Interference from cobalt(II), copper(II) and nickel(II) at 200ng mL–1 levels can be overcome by the addition of N-(dithio-carboxy)sarcosine. The recoveries for each 20 and 10 ng mL–1 vanadium added to the river water were 98 and 97%, respectively.The authors express their thanks to Miss Miho Suzuki and Miss Hiroyo Yamada for their experimental assistance in part.  相似文献   

11.
Guanine is determined at the 5.0×10–10 –2.0×10–7 mol/l level by differential-pulse adsorptive stripping voltammetry at a hanging mercury drop electrode using the reduction peak of its copper (II) complex at –0.21 V vs. Ag-AgCl electrode. The optimum analytical conditions were found to be Britton-Robinson buffer solution (pH 4.8), an accumulation potential of 0.0 V and an accumulation time of 3 min. Under these conditions, the detection limit is 5.0×10–10 mol/l and the relative standard deviation 2.6% for 1.0×10–7 mol/l guanine. The method is compared with the previous voltammetric methods. The presence of some purine derivatives does not interfere.  相似文献   

12.
A microcolumn of alumina modified with sodium dodecyl sulfate (SDS) and 1-(2-pyridylazo)-2-naphthol (PAN) was prepared for the preconcentration of trace nickel from water samples for a flame atomic absorption spectrometry (FAAS) determination. Under optimized conditions (pH = 4.0; flow rate, 5 mL min–1) nickel (II) was retained on the column. The nickel collected on the column was eluted with 5 mL of 0.5 M nitric acid. Recovery was greater than 96.7%. A concentration factor of 300 can be achieved by passing 1500 mL of sample through the microcolumn. The relative standard deviation (ten replicate analyses) at the 40 ng mL–1 level for nickel was 2.4%, and the corresponding limit of detection (based on 3) was 0.06 ng mL–1. The method was applied to the determination of Ni in waste and mineral waters.  相似文献   

13.
A new, simple, rapid, and sensitive spectrophotometric method has been developed for the determination of manganese in sewage. The method is based on the reaction of manganese with derivatives of 1,3,3-trimethyl-2-[3-(1,3,3-trimethyl-1,3-H-indol-2-ylidene)propenyl]-3H-indolium to form a colored ion associate with a sensitive absorption maximum at 560 nm. The appropriate reaction conditions have been established: pH 8.5–10.0, 1.25–2.3×10–3 mol L–1 1-nitroso-2-naphthol, and 1.6–2.4×10–4 mol L–1 dye reagent. Beer's law is obeyed for manganese concentrations up to 4.2 mg L–1. The limit of detection is 0.01 mg L–1 Mn2+; the molar absorptivity of the ion associate was 7.5×104 L mol–1 cm–1. The effect of various foreign ions was examined. A reaction mechanism is suggested. The developed procedure was tested for determination of manganese in sewage with satisfactory precision and accuracy.  相似文献   

14.
Zusammenfassung Zur potentiometrischen Manganbestimmung wird die Oxydation des Mangan(II)-Mannit-Komplexes mit Kaliumhexacyanoferrat(III) in alkalischer Lösung benutzt. Die Oxydation ist durch zwei gut ausgeprägte Potentialsprünge gekennzeichnet, die den Wertigkeitsübergängen Mangan(II) Mangan(III) und Mangan(III) Mangan(IV) entsprechen. Die Lösung soll 1 Mol/l KOH und 0,25–0,5 Mol/l Mannit enthalten. Der Konzentrationsbereich des bestimmbaren Mangans liegt zwischen 0,9 · 10–3 und 2,3 · 10–2 Mol/l.Die Bestimmung, die durch eine Reihe von Metallen nicht gestört wird, ist mit einem relativen Fehler von — 1% behaftet. Der störende Einfluß von Kobalt(II) wurde bis zu einem bestimmten Grad durch Zugabe von ÄDTA eliminiert, wobei nur ein gut meßbarer Potentialsprung auftritt, der der Oxydation Mangan(II) Mangan(IV) entspricht. Die Methode wurde mit guten Ergebnissen bei der Manganbestimmung im Schiefer und Kalkstein angewandt.
Summary The oxidation of complexes of manganese (II)-mannitol with hexacyanoferrate(III) in alkaline medium was utilized for the potentiometric determination of manganese. The oxidation is characterized by 2 potential jumps belonging to the reactions manganese(II) manganese(III) and manganese(III) manganese(IV). The optimum medium is 1 Mol/l of KOH and 0.25–0.5 Mol/l of mannitol, concentration range of manganese being between 0.9×10–3 and 2.3×10–2 Mol/l. The presence of some metals does not influence the determination, the relative error being — 1%. The interfering influence of cobalt(II) is eliminated to a certain extent by the addition of EDTA. In this medium, only one potential jump belonging to the oxidation of manganese(II) manganese(IV) appears. The method yields good results when applied to slate and limestone.
  相似文献   

15.
Summary Controlled adsorptive accumulation of Mo(VI)-2-BIBH at the hanging mercury drop electrode (HMDE) provides the basis for the direct stripping measurement of Mo(VI) in nanomolar concentration. The cathodic stripping response is evaluated with respect to experimental parameters such as preconcentration time, preconcentration potential and others. A differential pulse cathodic stripping voltammetric method for the determination of Mo(VI) with 2-BIBH in urine is proposed. The detection limit is 10–9 mol/l Mo(VI), standard deviation for 5×10–8 mol/l is ±1.58×10–9 mol/l.
Bestimmung von MolybdÄn(VI) mit 2-BenzylideniminobenzohydroxamsÄure (2-BIBH) in Harn durch kathodische Stripping-Voltammetrie
  相似文献   

16.
Summary The kinetics and mechanism of ligand substitution reactions of tetraethylenepentamine nickel(II), Ni (Teren), and triethylenetetraamine nickel(II), Ni(Trien), with 4-(2-pyridylazo)resorcinol (parH2) have been studied spectrophotometrically at I=0.1 M (NaClO4) at 25°C. In both systems two distinct reaction steps are observed. The rapid first step follows the rate law d[Ni(Polyamine)(ParH2)]/dt=k1 [Ni(Polyamine)] [ParH2]. The formation of ternary complexes of Ni (Polyamine) with ParH2 has been investigated under second order equal concentration conditions. The values of second order rate constants for the Trien and Teren reactions are (2.1±0.2)×104 M–1s–1 and (7.8±0.6)×103 M–1s–1 respectively at pH=9.0, I=0.1 M and 25°C.The rate law for the second step may be written as d[Ni(Par)2]/dt=k2[Ni(Polyamine)(ParH2)]. Values of k2 for the Trien and Teren systems are (2.5±0.1)×10–4 s–1 and (4.76±0.3)×10–5 s–1 respectively.  相似文献   

17.
Summary A new cationic dye, 1-(10-bromodecyl)-4-(4-aminonaphthylazo)-pyridinium bromide, was synthesized and evaluated as a new reagent for the determination of anionic surfactants. The reagent reacts with anionic surfactants, such as sodium dodecylsulphate and sodium dodecylbenzenesulphonate, to produce an ion associate in an aqueous medium. The colour change occurs simultaneously, and the colour development is very stable. This makes it possible to determine anionic surfactants directly by spectrophotometry without solvent extraction. The stoichiometric ratio of the ion associate was found to be 1:1 by the mole ratio method. The calibration graph was linear up to 2.5×10–6 mol/l. The apparent molar absorptivity of the ion associate was 5.3×104 l mol–1 cm–1 (at 595 nm). The relative standard deviation (n=10) for 1.2×10–6 mol/l sodium dodecylsulphate was 4.9%. The proposed method was applied to the determination of anionic surfactants in tap and river waters.  相似文献   

18.
Summary The spectrofluorimetric determination of terbium(III) in ethanol (95%) solution of acetylacetone (3×10–4 mol/l) was studied. Intensive fluorescence of terbium(III) (=545 nm) was observed after excitation of the system (=310 nm). The method proposed is satisfactory for the determination of terbium(III) in the range of 4 to 40 ng/ml (2.5×10–8 to 2.5×10–7 mol/l). The effect of other rare earths, common metal ions and anions upon the intensity of the fluorescence emitted by terbium(III) is discussed.
Spektrofluorimetrische Bestimmung von Tb(III)-Spuren mit Acetylaceton in Ethanollösung
  相似文献   

19.
The solvent extraction of thorium(IV) (4.3·10–4M) from nitric acid solution by bis-2-(butoxyethyl ether) (butex or DBC) has been studied. It has been investigated as a function of nitric acid, extractant and metal ion concentration. The effect of equilibration time, diverse ions and salting-out agent on the extraction has also been examined. Among anions, fluoride, phosphate, oxalate and perchlorate have reduced the extraction. Cations such as Na(I), K(I), Ca(II), Zn(II), Al(III), Ti(IV), Zr(IV) except Sr(II) and Pb(II) do not interfere in the extraction. The extraction is enhanced upto 97% in three stages at 6M HNO3 having 2.94M NaNO3 as salting-out agent. The extraction is found to be independent of thorium concentration in the range studied (4.3·10–4–4.3·10–2M). The temperature (18–45°C) has an adverse effect on the extraction. A 1% solution of ammonium bifluoride is found to be a good stripping solution and recovery of thorium is >98%.  相似文献   

20.
Summary A differential pulse polarographic method for the determination of iron employing the catalytic maximum wave has been studied. A well-defined differential pulse polarographic peak for iron(III) in Britton-Robinson buffer solution containing 50 mol/l N-(2-hydroxyethyl) ethylenediamine N,N,N-triacetic acid (HEDTA) and 5 mmol/l KBrO3 is observed in the potential range from +0.2 to –0.3 V vs. SCE. The peak current is very large compared to that of the Fe(III)/EDTA complex, being proportional to the concentration of iron(III) between 1.00×10–8 and 3.58×10–6 mol/l under optimum conditions. The relative standard deviations for 3.58×10–7 mol/l and 1.79×10–6 mol/l iron(III) were 1.38 and 0.54%, respectively (n=5), and the calculated detection limit was 5.2×10–9 mol/l iron(III). The method has been applied to the determination of iron in fresh snow and rain waters.
Spurenbestimmung von Eisen mit Hilfe der katalytischen Maximumsstufe in der Differential-Puls-Polarographie
Zusammenfassung Das Verfahren beruht auf der Tatsache, daß in Britton-Robinson-Puffer (mit 50 mol/l HEDTA und 5 mmol/l KBrO3) im Potentialbereich von +0,2 bis –0,3 V gegen SKE ein gut definierter puls-polarographischer Peak für Eisen(III) auftritt. Der Peakstrom ist im Vergleich zu dem des Fe(III)/EDTA-Komplexes sehr groß und ist unter optimalen Bedingungen im Konzentrationsbereich von 1,00·10–8 bis 3,58·10–6 mol/l der Eisen(III)-Konzentration proportional. Die relative Standardabweichung beträgt 1,38% bzw. 0,54% (n=5) für 3,58·10–7 mol/l bzw. 1,79·10–6 mol/l Fe(III). Die berechnete Nachweisgrenze liegt bei 5,2·10–9 mol/l Fe(III). Das Verfahren wurde zur Eisenbestimmung in Schnee- und Regenwasser eingesetzt.


This work was supported in part by a Grant-in-Aid for Scientific Research from Hokkaido-prefecture, 1982.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号