首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Complete PCB congener distributions in a panel of Aroclor mixtures were previously obtained by combining data from several HRGC systems. In that study quantitation of minor components may have been unreliable due to single level calibration against high levels of individual congener standards. Two lots of Aroclor 1254 had markedly different congener distributions. In this study, the design and performance of a congener-specific PCB analysis method employing GC-MS-SIM detection of congeners separated on a DB-XLB capillary column are discussed. Quantitation is carried out against a 6-level inclusive standard curve of a mixture of 144 congeners found in Aroclors. A separate procedure to measure trace levels of PCB 126 in Aroclors using the same system, combined with levels initially acquired for other congeners, facilitates estimation of TEQ values (Toxic Equivalencies of the PCB mixtures to 2,3,7,8-TCDD). PCB congener profiles of 15 Aroclor 1254 mixtures are presented. These profiles show that the less common, high TEQ variety of Aroclor 1254 was manufactured by an atypical, two-stage chlorination process that was apparently used during the final 1% of Aroclor 1254 production (ca. 1974–1976).  相似文献   

2.
Chlorobiphenyl congeners (CBs) are used as indicator compounds in analysis performed to determine whether or not PCB concentrations in food products, waste mineral oil, and environmental samples comply with the maximum levels permitted by legislation. Seven of these compounds have been checked for coelution with other CB congeners by means of a multidimensional gas chromatographic method utilizing a combination of two narrow bore columns, one coated with a conventional non-polar stationary phase and the other with a liquid crystalline (smectic) stationary phase. Peaks of the relevant CBs have been transferred, by heart cutting, from the non-polar column to the liquid crystal column, on which unambiguous separation from possible coeluting CB congeners was obtained. It has been shown that if the seven congeners are analyzed solely on a single, non-polar capillary column the results obtained for two of them may be affected by coelution of other compounds.  相似文献   

3.
Summary Supercritical carbon dioxide fluid extraction (SFE) has been used for selective extraction of nine aliphatic hydrocarbons, Aroclor 1260, Aroclor 5460, and four PCB congeners from chicken liver. Alumina was used as adsorbent and methanol as modifier. Recoveries were between 53 and 100% for aliphatic hydrocarbons, 83 and 95% for Aroclor 1260 and Aroclor 5460, and 81 and 98% for PCB congeners.  相似文献   

4.
High resolution gas chromatography has greatly changed the field of polychlorinated biphenyl (PCB) analysis. From a rough estimation of the total PCB concentration on packed column GC, the development of commercially available fused silica capillary columns in the late 1970s and early 1980s has advanced the analysis of PCBs to a point where they can be accurately measured as separated congeners. The state-of-the-art of PCB analysis in the 1990s is routine isomer-specific analysis with multi-column techniques using long (<50 m) narrow (> 0.25 mm) columns. A broad spectrum of commercially available stationary phases have been completely characterized with regard to their PCB elution profiles.  相似文献   

5.
非等间隔PCBs保留指数体系在光解行为研究中的应用   总被引:1,自引:0,他引:1  
苗秀生  储少岗  徐晓白 《色谱》1997,15(6):465-469
利用Chu等已建立的多氯联苯(PCBs)非等间隔保留指数体系,由文献中的相对保留时间计算出全部209种PCBs同类物(Congener)的保留指数(IPCB)。利用IPCB结合GC-MS对PCB87、PCB138和PCB169三种同类物的光解产物进行了定性分析,发现其光解产物主要为低氯代联苯。实验结果证明,非等间隔保留指数体系IPCB在PCBs同类物的定性分析中具有准确、实用、快捷、方便等优点。  相似文献   

6.
The congener-specific analysis of polychlorinated biphenyls (PCB) by high resolution gas chromatography on a 50 m × 0.25 mm fused silica column coated with a 0.26 μm film of 5% diphenyl polydimethylsiloxane (CPSil-8) has been significantly improved by series coupling with a 25 m × 0.22 mm column coated with a 0.10 μm film of 1,2-dicarba-closo-dodecarborane polydimethylsiloxane (HT-5). Using helium as carrier gas, a total of 64 congeners in technical PCB mixtures could be analyzed as resolved peaks by ECD (86 by MS) with the CPSil-8 column, and 84 by ECD (108 by MS) with the combination. The high upper temperature limit for these stationary phases (>300°C) enabled fast temperature programming and rapid analysis (60 min).  相似文献   

7.
Levels and patterns of polychlorinated biphenyls (PCBs) were studied in surface soil samples collected in the coastal part of Croatia within and surrounding four different airports and in the vicinity of two partially devastated electrical transformer stations. The compounds accumulated from air-dried soil samples by multiple ultrasonic extraction with an n-hexane?:?acetone 1?:?1 mixture were analysed by capillary gas chromatography with electron capture and ion-trap detection. PCBs were quantified against a standard Aroclor 1242/Aroclor 1260 mixture and a standard mixture of 17 individual PCB congeners (IUPAC No.: 28, 52, 60, 74, 101, 105, 114, 118, 123, 138, 153, 156, 157, 167, 170, 180, and 189). The mass fractions of total PCBs in 18 soil samples collected within the airport premises ranged from 3 to 41?327?µg/kg dry weight (dw) (median: 533?µg/kg?dw), and those in 21 samples collected at a distance ranging from several metres to 5?km away from the airport fence, from <1 to 39?µg/kg?dw (median: 5?µg/kg?dw). The highest PCB levels were determined in soils along the airport aprons where the aircrafts were serviced and refuelled. The PCB pattern was very similar to technical Aroclor 1260 in all airport soils. The PCB pattern in 22 soils collected in the vicinity of electrical transformer stations was dominated by congeners contained in Aroclor 1242. These soils contained 7 to >400?µg/kg?dw of total PCBs. One highly PCB-contaminated airport soil sample was analysed for polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs). With an international toxic equivalent (I-TEQ) of 9.7?ng/kg?dw, the airport soil contamination was within values typical for urban and rural areas, and the congener patterns gave no clear indication for PCBs as the only source of PCDDs/PCDFs.  相似文献   

8.
The simultaneous analysis of α-HCH, β-HCH, γ-HCH, HCB, p,p′-DDD, p,p′-DDT, p,p′-DDE, o,p′-DDT, mirex, dieldrin and 62 chlorobiphenyl congeners on two parallel capillary GC columns of different polarity is described for nine Mediterranean fish species. Ten commercially available columns with stationary phases completely characterized in respect of their PCB elution patterns were considered for dual-column GC-ECD analysis. The combination of a 60 m × 0.25 mm i.d. column coated with a 0.25 μm film of 50% diphenyl dimethylsiloxane and a series combination of a 25 m × 0.25 mm i.d. column coated with a 0.25 μm film of 5% diphenyl dimethylsiloxane with a 25 m × 0.22 mm i.d. column coated with a 0.10 μm film of 1, 10-dicarba-closo-dodecarborane dimethylpolysiloxane furnished the highest number of separated chlorobiphenyl congeners (104). The dual-column GC system performed with high stability and reproducibility over a broad concentration range (1–3000 ng/g lipid) of the organochlorine compounds in the investigated fish.  相似文献   

9.
Summary With the HPLC carbon column Shandon Hypercarb, the polychlorinated biphenyl congeners are separated by a gradient mixture of acetonitrile and toluene in such a way that the congeners with two (or more) orthochlorine substituents are eluted first, followed by those with one ortho-chlorine and at last the coplanar congeners. Within each group, subfractionation is observed according to the total number of chlorines. For GLC, the SGE HT 5 capillary column exhibits a much more efficient separation of 65 congeners found in Clophen A 40 than the usual DB-5 column, especially for the higher chlorinated congeners. Therefore, the HPLC fractionation on Shandon Hypercarb combined with the GLC on HT 5 offers new possibilities for the analysis of the toxicologically relevant coplanar and mono-ortho substituted PCB congeners.  相似文献   

10.
Abstract

Four bacterial isolates belonging to the genera Pseudomonas and Alcaligenes were obtained by the enrichment method, using biphenyl as the sole carbon source, from the soil, which underwent long-time contamination with technical mixtures of PCB. Kinetics of PCB degradation by individual isolates was measured using n-hexane extraction of the cultivation media in proper time intervals and analysed by congener specific gas chromatography with electron capture detection. All isolates exhibit interesting biodegradative potential. Specific degradation of individual congeners with respect to the number and position of chlorine substituents is discussed. The influence of glucose, biphenyl and 3-chlorobenzoic acid on the PCB degradation has been assessed.  相似文献   

11.
A total of 196 out of 209 polychlorobiphenyl (PCB) congeners were resolved using GC×GC-TOFMS with a non-polar/ionic liquid column series consisting of poly(50%-n-octyl-50%-methyl)siloxane and (1,12-di(tripropylphosphonium)dodecane bis(trifluoromethansulfonyl)amide) in the first and second dimension, respectively. It has been found that 13 PCB congeners overlap in five doublets (CB12+CB13, CB62+CB75, CB70+CB76, CB97+CB125 and CB153+CB168) and one triplet (CB90+CB101+CB113). All toxic, "dioxin like" congeners were separated with no interferences from any PCB congener. The 109 PCBs present in Aroclor 1242 and the 82 PCBs present in Aroclor 1260 were resolved GC×GC-TOFMS analysis on this column set.  相似文献   

12.
The retention characteristics of all 209 polychlorinated biphenyl (PCB) congeners were determined on a new p,p-cyanobiphenyl stationary phase using gas chromatography with electron capture detection (GC-ECD). Response factors were determined relative to decachlorobiphenyl, PCB 209. Several congeners that coelute on the phases routinely used for PCB analysis are separated on this phase, including the hexachlorobiphenyls 138, 163, and 164. The p,p-cyanobiphenyl stationary phase exhibits altered retention for planar congeners, such that the toxic coplanar PCBs 77, 126, and 169 are eluted free from interference. Of the 209 congeners, 61 were separated using the p,p-cyanobiphenyl phase in conjunction with GC-ECD. When analyzed by gas chromatography with mass selective detection (GC-MSD), the number of congeners determined increased to 133. Therefore GC-MSD was used with the p,p-cyanobiphenyl phase to characterize three PCB mixtures: Aroclor 1242, Aroclor 1254, and Aroclor 1260.  相似文献   

13.
The feasibility of comprehensive two-dimensional gas chromatography with electron-capture detection (GC x GC-ECD) for the enantioseparation of chiral PCBs from other possible interfering compounds has been evaluated. Three commercially available enantioselective beta-cyclodextrin-based capillary columns (Chirasil-Dex, BGB-172 and BGB-176SE) have been tested as first-dimension columns. Three non-enantioselective stationary phases (HT-8, BPX-50 and Supelcowax-10) were combined with the enantioselective columns to allow the unambiguous determination of the enantiomers of the target chiral PCBs. Each enantioselective first-dimension column tested was able to separate into enantiomers different PCB congeners, but in all cases, the use of Supelcowax-10 as second-dimension column provided the most satisfactory results. The Chirasil-Dex x Supelcowax-10 column combination allowed the determination of the enantiomeric fraction (EF) of PCBs 84, 91, 95, 132, 136, 149, 174 and 176 in the working standard solution, while that of congener 135 was hindered. The BGB-172 x Supelcowax-10 column set allowed a proper EF determination of congeners 45, 84, 131, 132, 135, 171, 174 and 183, while that of PCB 91 was interfered with co-elutants. The column combination BGB-176SE x Supelcowax-10 allowed the determination of all congeners that this enantioselective stationary phase was able to separate into enantiomers, i.e. PCBs 45, 91, 95, 136, 149 and 176. These column combinations have also been evaluated for the simultaneous determination of the 12 congeners with a toxic equivalency factor assigned by the WHO (PCBs 77, 81, 105, 114, 118, 123, 126, 156, 157, 167, 169, 189) and the seven indicator congeners (PCBs 28, 52, 101, 118, 138, 153 and 180), and evaluated for the analysis of food samples.  相似文献   

14.
A simple dual-column gas chromatographic system with a six-port switching valve has been used to separate the atropisomers of PCB congeners 84, 91, and 95 in technical PCB formulations and in extracts of soil and river sediment. A capillary column coated with a methylphenylsiloxane stationary phase (CP-Sil 8) was used as the first column, for retention window selection, and a permethylated β-cyclodextrin (ChirasilDex) capillary column as the main separation column. Because peak overlap could not be eliminated by optimization of column temperature, the enantiomeric ratios of PCB congeners could not be determined from the original chromatograms. The correct enantiomer ratio was determined from the peak areas obtained by deconvolution of the chromatograms. Whereas the PCB atropisomers considered were present in equal concentrations in the technical PCB formulations, analysis of a river sediment sample confirmed different residual concentrations of the atropisomers of congener 95.  相似文献   

15.
Abstract

Polychlorinated biphenyls (PCBs) are toxic, perssstent, global environmental contaminants which were formulated as complex mixtures of congeners. Many methods have been developed in the past to analyze PCB in transformer oil samples for regulatory purposes. The most important consideration in the cleanup procedure is the ability to remove the oil from the sample matrix, since trace amount of oil will interfere with the subsequent GC-MS analysis. Electron capture detection (ECD) has been the most common method for gas chromatographic analysis of PCBs because of its high sensitivity toward halogenated compounds. ECD can also respond to some non-PCB compound resulting in biased concentrations of PCB. In this work, a two-stage cleanup method, using DMSO liquid/liquid extraction and HPLC column chromatography. has been applied to two types of transformer oil. Five internal standards have been selected to show their performance in the presence of different oil matrices. The comparison of the PCB quantification at different conditions for GC-MS and GC-ECD will be demonstrated.  相似文献   

16.
Abstract

The anaerobic degradation of PCB in loamy and clayey soils containing indigeneous microflora was studied. The anaerobic conditions were created by an argon atmosphere in the flasks containing soil flooded by a liquid medium with glucose. GC-ECD analysis of soil extracts after 40 day incubation showed, in addition to the concentration changes of the less chlorinated PCB congeners, a significant decrease in the concentration of highly chlorinated congeners in both soils. The results indicate that in both soil types reductive dehalogenation of PCB congeners was encountered.  相似文献   

17.
Summary Fourteen polychlorinated biphenyl (PCB) congeners were quantified in air samples of the tropospheric boundary layer of the Atlantic Ocean. The samples were taken on the German research vessel Polarstern during north-south cruises across the Atlantic Ocean (1990, 1991), and on the Capo Verde islands in the North Atlantic Ocean (1992). Values for the sum of PCB were between 48 pg/m3 (values for the seven indicator congeners were [in pg/m3]: PCB 28: 1.3; PCB 52: 5.0; PCB 101: 3.0; PCB 118: 0.5; PCB 138: 1; PCB 153: 1; PCB 180: <0.2) in the Westwind Belt of the eastern North Atlantic and 22 pg/m3 (values for the seven indicator congeners were [in pg/m3]: PCB 28: 2.3; PCB 52: 3.4; PCB 101: 0.5; PCB 118: <0.2; PCB 138: <0.2; PCB 153: <0.2; PCB 180: <0.2) in the Westwind Belt of the central South Atlantic. Up to 385 pg/m3 (values for the seven indicator congeners were [in pg/m3]: PCB 28: 2.6; PCB 52: 11.7; PCB 101: 28.4; PCB 118: 9; PCB 138: 21; PCB 153: 18; PCB 180: 5.5) were measured of the coast of South Patagonia. A difference depending on latitude and on terrestrial influenced air masses between the lower and the higher chlorinated congeners was observed. The levels of three- and tetrachlorinated congeners were highest in the Trade Wind regions. The contents of the higher chlorinated congeners had maxima in samples influenced by continental air masses. A correlation of the levels of the lower chlorinated congeners in air over the South Atlantic with the surface water temperature and thus with the temperature dependent gas/water partition coefficient Kgw was observed. Part XVI: Fischer RC, Krämer W, Ballschmiter K (1991) Chemosphere 23:889–900  相似文献   

18.
Multidimensional chromatography was used to resolve the specific chlorobiphenyl (CB) congeners 28, 52, 101, 118, 138, 153, and 180 in technical aroclor standards. Single column analysis of polychlorinated biphenyls (PCBs) results in co-elution of key congeners with other components in the mixture; therefore using two columns of different selectivity was necessary to enhance the resolution achievable on just one column. The HT8 column (8% phenylpolycarborane-siloxane phase) has been reported to have specific selectivity characteristics for improved PCB separation. When coupled with a BPX5 column (5% phenylpolysiloxane-silphenylene phase), it has been shown here to provide unambiguous identification of 7 marker compounds which are used to monitor PCB occurrence and distribution. All seven marker CBs are present in aroclor 1254, and by adjusting the size of the heartcut window, it was possible to obtain resolution of the marker congeners from other congeners. Single column analysis is unable to achieve this result. This offers an alternative to GC-MS analysis.  相似文献   

19.
Summary The fractionation of PCB congeners into classes according to their planarity (i.e. amount of ortho substitution) by HPLC on porous graphitic carbon (PGC) as stationary phase has been investigated as a preliminary step before GC analysis, indispensable for a complete separation of PCB congeners. A systematic study of retention behavior on PGC eluted with different n-hexane-dichloromethane mixtures made it possible to design a linear binary gradient which separated PCB congeners in a reasonable time and with good performance. Relationships were obtained between retention behavior and the molecular structure of the PCB congeners. The beneficial effects of elevated temperature on separation efficiency were also investigated. The analysis conditions selected, i.e. continuous gradient separation at 40°C, were successfully used for fractionation of technical PCB formulations, e.g. Aroclor 1242.  相似文献   

20.
A novel p,p-cyanobiphenyl stationary phase (p-cyanobiphenyl, p-allyloxy methylpolysiloxane) has been evaluated for the GC investigation of polychlorinated biphenyls (PCBs). Several PCB congeners which coelute on the phases typically used for PCB analysis (e.g. 5% phenyl methylpolysiloxane) are separated on the p,p-cyanobiphenyl phase, including the hexachlorobiphenyl congeners PCB 163, PCB 164, and PCB 138. In this work, a p,p-cyanobiphenyl stationary phase was used to measure selected PCB congeners in two Standard Reference Materials (SRMs) available from the National Institute of Standards and Technology (NIST), and two Certified Reference Materials (CRMs) available from the Community Bureau of Reference (BCR). The materials analyzed were SRM 1588, Organics in Cod Liver Oil; SRM 1945, Organics in Whale Blubber; CRM 349, Chlorobiphenyls in Cod Liver Oil; and CRM 350, Chlorobiphenyls in Mackerel Oil. Concentrations are reported for several PCB congeners which coelute on the 5% phenyl methylpolysiloxane, including PCB 163 and PCB 164.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号