首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Calcium (Ca2+) is a ubiquitous intracellular second messenger and involved in a plethora of cellular processes. Thus, quantification of the intracellular Ca2+ concentration ([Ca2+]i) and of its dynamics is required for a comprehensive understanding of physiological processes and potential dysfunctions. A powerful approach for studying [Ca2+]i is the use of fluorescent Ca2+ indicators. In addition to the fluorescence intensity as a common recording parameter, the fluorescence lifetime imaging microscopy (FLIM) technique provides access to the fluorescence decay time of the indicator dye. The nanosecond lifetime is mostly independent of variations in dye concentration, allowing more reliable quantification of ion concentrations in biological preparations. In this study, the feasibility of the fluorescent Ca2+ indicator Oregon Green Bapta-1 (OGB-1) for two-photon fluorescence lifetime imaging microscopy (2P-FLIM) was evaluated. In aqueous solution, OGB-1 displayed a Ca2+-dependent biexponential fluorescence decay behaviour, indicating the presence of a Ca2+-free and Ca2+-bound dye form. After sufficient dye loading into living cells, an in situ calibration procedure has also unravelled the Ca2+-free and Ca2+-bound dye forms from a global biexponential fluorescence decay analysis, although the dye's Ca2+ sensitivity is reduced. Nevertheless, quantitative [Ca2+]i recordings and its stimulus-induced changes in salivary gland cells could be performed successfully. These results suggest that OGB-1 is suitable for 2P-FLIM measurements, which can gain access to cellular physiology.
Figure
Procedure of quantitative Ca2+ recordings in cockroach salivary gland cells using time-resolved fluorescence measurements with the Ca2+-sensor OGB-1  相似文献   

2.
The topology of the GCAP-2 homodimer was investigated by chemical cross-linking and high resolution mass spectrometry. Complementary conducted size-exclusion chromatography and analytical ultracentrifugation studies indicated that GCAP-2 forms a homodimer both in the absence and in the presence of Ca2+. In-depth MS and MS/MS analysis of the cross-linked products was aided by 15 ? N-labeled GCAP-2. The use of isotope-labeled protein delivered reliable structural information on the GCAP-2 homodimer, enabling an unambiguous discrimination between cross-links within one monomer (intramolecular) or between two subunits (intermolecular). The limited number of cross-links obtained in the Ca2+-bound state allowed us to deduce a defined homodimeric GCAP-2 structure by a docking and molecular dynamics approach. In the Ca2+-free state, GCAP-2 is more flexible as indicated by the higher number of cross-links. We consider stable isotope-labeling to be indispensable for deriving reliable structural information from chemical cross-linking data of multi-subunit protein assemblies.
Figure
?  相似文献   

3.
Calmodulin (CaM) is a highly conserved intracellular Ca2+-binding protein that exerts important functions in many cellular processes. Prominent examples of CaM-regulated proteins are adenylyl cyclases (ACs), which synthesize cAMP as a central second messenger. The interaction of ACs with CaM represents the link between Ca2+-signaling and cAMP-signaling pathways. Thereby, different AC isoforms stimulated by CaM, comprise diverse mechanisms of regulation by the Ca2+ sensor. To extend the structural information about the detailed mechanisms underlying the regulation of AC8 by CaM, we employed an integrated approach combining chemical cross-linking and mass spectrometry with two peptides representing the CaM-binding regions of AC8. These experiments reveal that the structures of CaM/AC8 peptide complexes are similar to that of the CaM/skeletal muscle myosin light chain kinase peptide complex where CaM is collapsed around the target peptide that binds to CaM in an antiparallel orientation. Cross-linking experiments were complemented by investigating the binding of AC8 peptides to CaM thermodynamically with isothermal titration calorimetry. There were no hints on a complex, in which both AC8 peptides bind simultaneously to CaM, refining our current understanding of the interaction between CaM and AC8.
Figure
The interactions between calmodulin and two peptides, derived from the N- and C-termini of adenylyl cyclase 8, were analyzed by chemical cross-linking and mass spectrometry  相似文献   

4.
From extraction experiments and $ \gamma $ -activity measurements, the exchange extraction constants corresponding to the general equilibrium M2+(aq) + Sr2+(nb) $ \Leftrightarrow $ M2+(nb) + Sr2+(aq) taking place in the two-phase water–nitrobenzene system (M2+ = Mg2+, Ca2+, Ba2+, Pb2+, Cu2+, Zn2+, Cd2+, $ {\hbox{UO}}_{2}^{2 + } $ , Mn2+, Co2+, Ni2+; 1 = macrocyclic lactam receptor–see Scheme 1; aq = aqueous phase, nb = nitrobenzene phase) were evaluated. Moreover, the stability constants of the M2+ complexes in nitrobenzene saturated with water were calculated; they were found to increase in the following cation order: Mg2+ < Co2+ < Cu2+, Mn2+, Ni2+ < Cd2+ < Ca2+ < Ba2+, Zn2+ < Pb2+ <  $ {\hbox{UO}}_{2}^{2 + } $ .
Scheme 1
Structural formula of 2,18-dichloro-9,10,11,12-tetrahydro-6H, 20H-dibenzo[l,o][1,11,4,8]dioxadiazacyclohexadecine-7,13(8H, 14H)-dione (abbrev. 1)  相似文献   

5.
This study describes the development of a microfluidic device for the high-throughput screening of culture conditions, such as the optimum sodium acetate concentration for promoting rapid growth and high lipid accumulation of Chlamydomonas reinhardtii. An analysis of the microalgal growth on the microfluidic device revealed an optimum sodium acetate concentration of 5.72 g L?1. The lipid content, determined by the 4,4-Difluoro-1,3,5,7-tetramethyl-4-bora-3a,4a-diaza-s-indacene (BODIPY® 505/515) staining method, increased with the sodium acetate concentration. The results were found to be statistically reproducible with respect to cell growth and lipid production. Other nutrient conditions, including the nitrogen and phosphorus concentrations, can also be optimized on the same microfluidic platform. The microfluidic device performance results agreed well with the results obtained from the flask-scale experiments, validating that the culture conditions were scalable. Finally, we, for the first time, established a method for the absolute quantification of the microalgal lipid content in the picoliter culture volumes by comparing the on-chip and off-chip data. In conclusion, we successfully demonstrated the high-throughput screening of sodium acetate concentrations that induced high growth rates and high lipid contents in C. reinhardtii cells on the microfluidic device.
Figure
We have developed a microfluidic device for the high-throughput screening of culture conditions for promoting rapid growth and high lipid accumulation of Chlamydomonas reinhardtii  相似文献   

6.
By taking advantage of the intrinsic fluorescence of ochratoxin A (OTA), we present a fluorescence anisotropy approach for rapid analysis of the interactions between OTA and aptamers. The specific binding of OTA with a 36-mer aptamer can induce increased fluorescence anisotropy (FA) of OTA as the result of the freedom restriction of OTA and the increase of molecular volume, and the maximum FA change is about 0.160. This FA approach enables an easy way to investigate the effects of buffer compositions like metal ions on the affinity binding. FA analysis shows the interaction between OTA and aptamer is greatly enhanced by the simultaneous presence of Ca2+ and Na+, while the binding affinity of aptamer decreases more than 18-fold when only Ca2+ exists, and the binding is completely lost when Ca2+ is absent. Crucial region of the aptamer for binding can be mapped through FA analysis and aptamer mutation. The demonstrated FA approach maintains the advantages of FA in simplicity, rapidity, and robustness. This investigation will help the development of aptamer-based assays for OTA detection in optimizing the binding conditions, modification of aptamers, and rational design.
Figure
The free ochratoxin A (OTA) molecule tumbles rapidly and shows low fluorescence anisotropy (FA), while the bound OTA by the aptamer has increased molecular volume and restricted freedom, showing enhanced FA. FA analysis allows screening the interaction between OTA and aptamer  相似文献   

7.
The trapping or immobilization of individual cells at specific locations in microfluidic platforms is essential for single cell studies, especially those requiring cell stimulation and downstream analysis of cellular content. Selectivity for individual cell types is required when mixtures of cells are analyzed in heterogeneous and complex matrices, such as the selection of metastatic cells within blood samples. Here, we demonstrate a microfluidic device based on direct current (DC) insulator-based dielectrophoresis (iDEP) for selective trapping of single MCF-7 breast cancer cells from mixtures with both mammalian peripheral blood mononuclear cells (PBMC) as well MDA-MB-231 as a second breast cancer cell type. The microfluidic device has a teardrop iDEP design optimized for the selective capture of single cells based on their differential DEP behavior under DC conditions. Numerical simulations adapted to experimental device geometries and buffer conditions predicted the trapping condition in which the dielectrophoretic force overcomes electrokinetic forces for MCF-7 cells, whereas PBMCs were not trapped. Experimentally, selective trapping of viable MCF-7 cells in mixtures with PBMCs was demonstrated in good agreement with simulations. A similar approach was also executed to demonstrate the selective trapping of MCF-7 cells in a mixture with MDA-MB-231 cells, indicating the selectivity of the device for weakly invasive and highly invasive breast cancer cells. The DEP studies were complemented with cell viability tests indicating acceptable cell viability over the course of an iDEP trapping experiment.
Figure
?  相似文献   

8.
We have investigated the response of normal and cancer cells to exposure a combination of celecoxib (Celbx) and 5-fluorouracil (5-FU) using a lab-on-a-chip microfluidic device. Specifically, we have tested the cytotoxic effect of Celbx on normal mouse embryo cells (Balb/c 3T3) and human lung carcinoma cells (A549). The single drugs or their combinations were adjusted to five different concentrations using a concentration gradient generator (CGG) in a single step. The results suggest that Celbx can enhanced the anticancer activity of 5-FU by stronger inhibition of cancer cell growth. We also show that the A549 cancer cells are more sensitive to Celbx than the Balb/c 3T3 normal cells. The results obtained with the microfluidic system were compared to those obtained with a macroscale in vitro cell culture method. In our opinion, the microfluidic system represents a unique approach for an evaluation of cellular response to multidrug exposure that also is more simple than respective microwell plate assays.
Figure
?  相似文献   

9.
We report on a microfluidic platform that integrates a winding microdroplet chip and a surface-enhanced Raman scattering (SERS) detection system for trace determination of crystal violet (CV). Colloidal silver was applied to generate SERS. Compared to the continuous flow microfluidic system, the microdroplet based detection described here effectively eliminates any memory effects. Effects of flow pattern, droplet size, surfactant, and position of detection were optimized. Under optimal conditions, there is a linear correlation between signal and the concentration of CV in the 10 nM to 800 nM range, with a correlation coefficient (R2) of 0.9967. The limit of detection in water is 3.6 nM.
Graph
A winding microdroplet chip based on SERS detection was developed for trace levels of crystal violet. Under optimal conditions,there is a good linear correlation in the 10 nM to 800 nM range with LOD is 3.6 nM.  相似文献   

10.
Heterogeneity of cell populations in various biological systems has been widely recognized, and the highly heterogeneous nature of cancer cells has been emerging with clinical relevance. Single-cell analysis using a combination of high-throughput and multiparameter approaches is capable of reflecting cell-to-cell variability, and at the same time of unraveling the complexity and interdependence of cellular processes in the individual cells of a heterogeneous population. In this review, analytical methods and microfluidic tools commonly used for high-throughput, multiparameter single-cell analysis of DNA, RNA, and proteins are discussed. Applications and limitations of currently available technologies for cancer research and diagnostics are reviewed in the light of the ultimate goal to establish clinically applicable assays.
Figure
?  相似文献   

11.
Conventionally, microbial bioelectrochemical assays have been conducted using immobilized cells on an electrode that is placed in an electrochemical batch cell. In this paper, we describe a developed microfluidic platform with integrated microelectrode arrays for automated bioelectrochemical assays utilizing a new double mediator system to map redox metabolism and screen for genetic modifications in Saccharomyces cerevisiae cells. The function of this new double mediator system based on menadione and osmium redox polymer (PVI-Os) is demonstrated. “Wiring” of S. cerevisiae cells using PVI-Os shows a significant improvement of bioelectrochemical monitoring in a microfluidic environment and functions as an effective immobilization matrix for cells that are not strongly adherent. The function of the developed microfluidic platform is demonstrated using two strains of S. cerevisiae, ENY.WA and its deletion mutant EBY44, which lacks the enzyme phosphoglucose isomerase. The cellular responses to introduced glucose and fructose were recorded for the two S. cerevisiae strains, and the obtained results are compared with previously published work when using an electrochemical batch cell, indicating that microfluidic bioelectrochemical assays employing the menadione–PVI-Os double mediator system provides an effective means to conduct automated microbial assays.
Figure
Microfluidic platform for bioelectrochemical assays using osmium redox polymer “wired” living yeast cells  相似文献   

12.
Sulfated N-glycans released from bovine thyroid stimulating hormone (bTSH) were ionized with the divalent metal cations Ca2+, Mg2+, and Co by electrospray ionization (ESI). These metal-adducted species were subjected to infrared multiphoton dissociation (IRMPD) and electron capture dissociation (ECD) and the corresponding fragmentation patterns were compared. IRMPD generated extensive glycosidic and cross-ring cleavages, but most product ions suffered from sulfonate loss. Internal fragments were also observed, which complicated the spectra. ECD provided complementary structural information compared with IRMPD, and all observed product ions retained the sulfonate group, allowing sulfonate localization. To our knowledge, this work represents the first application of ECD towards metal-adducted sulfated N-glycans released from a glycoprotein. Due to the ability of IRMPD and ECD to provide complementary structural information, the combination of the two strategies is a promising and valuable tool for glycan structural characterization. The influence of different metal ions was also examined. Calcium adducts appeared to be the most promising species because of high sensitivity and ability to provide extensive structural information.
Figure
?  相似文献   

13.
We report an extremely sensitive and specific detection of mercuric ions (Hg2+) based on graphene assisted laser desorption/ionization mass spectrometry (GALDI-MS). Combining the highly selective coordination interactions between thymine (T) and Hg2+, we present a simple, effective, and novel approach, based on π–π interactions of the T-Hg2+-T complex and G that can serve as a platform and matrix for GALDI-MS. The present sensor not only exhibits high selectivity and sensitivity (picomolar) to Hg2+ in aqueous solution, but also can elucidate the chemical structures of the metal complexes. The significant advantage in the current approach is that there is no need for a sophisticated instrument, and no sample pretreatment is required to detect the Hg2+ ions.
Figure
?  相似文献   

14.
Collision-induced dissociation (CID) of electrosprayed protein complexes usually involves asymmetric charge partitioning, where a single unfolded chain gets ejected that carries a disproportionately large fraction of charge. Using hemoglobin (Hb) tetramers as model system, we confirm earlier reports that bound metal ions can stabilize protein complexes under CID conditions. We examine the mechanism underlying this effect. Nonvolatile salts cause extensive adduct formation. Significant stabilization was observed for Mg2+ and Ca2+, whereas K+, Rb+, and Cs+ had no effect. Precursor ion selection was used to examine Hb subpopulations with well-defined metal binding levels. K+, Rb+, and Cs+-adducted tetramers eject monomers that carry roughly one-quarter of the metal ions that were bound to the precursor. This demonstrates that charge migration during CID is exclusively due to proton transfer, not metal ion transfer. Also, replacement of highly mobile charge carriers (protons) with less mobile species (metal ions) does not exert a stabilizing influence under the conditions used here. Interestingly, Hb carrying stabilizing ions (Mg2+ and Ca2+) generates monomeric CID products that are metal depleted. This effect is attributed to a combination of two factors: (1) Me2+ binding stabilizes Hb via formation of chelation bridges (e.g., R-COO Me2+ OOC-R); the more Me2+ a subunit contains the more stable it is. (2) More than ~90 % of the tetramers contain at least one subunit with a below-average number of Me2+. The prevalence of monomeric CID products with depleted Me2+ levels is caused by the tendency of these low metal-containing subunits to undergo preferential unfolding/ejection.
Figure
?  相似文献   

15.
We report on a small (20?×?10 mm) micromachined device for the detection of gases in micro-gas chromatography (GC). It incorporates a micro-discharge across a 20-μm gap, and a remote electrode in the micro cavity that generates an electrical signal corresponding to the photo-ionization of gaseous analytes in a stream of carrier gas. Multi-component mixtures were detected and the results compared to those obtained with a flame ionization detector. The minimum detectable limit is 350 pg.μL?1 of n-octane in air when applying a 1.4 mW discharge. The combination of wet etching of glass (as used for microfluidic channels) with a lift-off process for detector electrodes by a robust batch process results in a universal, non-destructive, and sensitive microdetector for micro-GC.
Figure
?  相似文献   

16.
From extraction experiments and γ-activity measurements, the exchange extraction constant corresponding to the equilibrium Ca2+(aq) + 1·Sr2+(nb) ? 1·Ca2+(nb) + Sr2+(aq) taking place in the two-phase water–nitrobenzene system (1 = beauvericin; aq = aqueous phase, nb = nitrobenzene phase) was evaluated as log K ex(Ca2+, 1·Sr2+) = 1.1 ± 0.1. Further, the stability constant of the 1·Ca2+ complex in nitrobenzene saturated with water was calculated for a temperature of 25 °C: log β nb(1·Ca2+) = 10.1 ± 0.2. Finally, by using quantum mechanical density functional level of theory calculations, the most probable structures of the non-hydrated 1·Ca2+ and hydrated 1·Ca2+·H2O complex species were predicted.  相似文献   

17.
An integrated micro/nano-fluidic system is presented for protein analysis. It is comprised of an integrated micromixer (IMM) and a preconcentrator with a separation column. The passive and planar type of IMM is based on an unbalanced split and the cross collision of the fluidic streams. The IMM can be easily fabricated and integrated to the microfluidic system. The preconcentrator has nanochannels formed by the electrical breakdown of polydimethylsiloxane (PDMS) membrane by applying a high electrical shock, but without any nano-lithography. The integrated microdevice was used for sample preparation (mixing with tagging molecules) and subsequent concentration of proteins. Proteins were electrokinetically trapped near the junction of the micro/nanochannels. We show a conceptual design and a simple microfluidic system for purposes of mixing and preconcentration.
Figure
Mixing and preconcentration of dissolved proteins using an integrated micro/nano-fluidic system  相似文献   

18.
A conventional electron capture dissociation (ECD) spectrum of a protein is uniquely characteristic of the first dimension of its linear structure. This sequence information is indicated by summing the primary c m+ and z m+? products of cleavage at each of its molecular ion’s inter-residue bonds. For example, the ECD spectra of ubiquitin (M?+?nH)n+ ions, n?=?7–13, provide sequence characterization of 72 of its 75 cleavage sites from 1843 ions in seven c (1–7)+ and eight z (1–8)+? spectra and their respective complements. Now we find that each of these c/z spectra is itself composed of “charge site (CS)” spectra, the c m+ or z m+? products of electron capture at a specific protonated basic residue. This charge site has been H-bonded to multiple other residues, producing multiple precursor ion forms; ECD at these residues yields the multiple products of that CS spectrum. Closely similar CS spectra are often formed from a range of charge states of ubiquitin and KIX ions; this indicates a common secondary conformation, but not the conventional α-helicity postulated previously. CS spectra should provide new capabilities for comparing regional conformations of gaseous protein ions and delineating ECD fragmentation pathways.
Figure
?  相似文献   

19.
In order to reveal the time-depending mercury species uptake by human astrocytes, a novel approach for total mercury analysis is presented, which uses an accelerated sample introduction system combined on-line with an inductively coupled plasma mass spectrometer equipped with a collision/reaction cell. Human astrocyte samples were incubated with inorganic mercury (HgCl2), methylmercury chloride (MeHgCl), and thimerosal. After 1-h incubation with Hg2+, cellular concentrations of 3 μM were obtained, whereas for organic species, concentrations of 14–18 μM could be found. After 24 h, a cellular accumulation factor of 0.3 was observed for the cells incubated with Hg2+, whereas the organic species both showed values of about 5. Due to the obtained steady-state signals, reliable results with relative standard deviations of well below 5 % and limits of detection in the concentration range of 1 ng L?1 were obtained using external calibration and species-unspecific isotope dilution analysis approaches. The results were further validated using atomic fluorescence spectrometry.
Figure
?  相似文献   

20.
We describe a microbial sensor based on Pseudomonas fluorescens cells that was prepared by modifying graphite electrodes with chitosan and carbon nanotubes. Chronoamperometry was performed at +0.3 V in the presence of hexacyanoferrate as a mediator and revealed a good response to glucose which is linear in the 1.0 to 5.0 mM concentration range. Linearity was defined by the equation of y?=?102.120x?13.279 (R 2?=?0.998) (y shows current density as nA.cm?2 and x shows glucose concentration in mM). The effect of the CNTs on the response was compared to that of electrodes made without CNTs.
Figure
A mediated microbial sensor that was prepared by modifying graphite electrodes with chitosan and carbon nanotube and Pseudomonas fluorescens cells has been described. As well as some parameters (pH, mediator and cell amount etc), the effect of CNTs on the response was compared to that of electrodes made without CNTs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号