首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 22 毫秒
1.
Strelow FW 《Talanta》1980,27(3):231-236
Gallium can be separated from Zn, Cu(II), In, Cd, Pb(II), Bi(III), Au(III), Pt(IV), Pd(II), Tl(III), Sn(IV) and Fe(III) by elution of these elements with 0.50M hydrobromic acid in 80% acetone medium, from a column of AG50W-X4 cation-exchange resin. Gallium is retained and can be eluted with 3M hydrochloric acid. Separations are sharp and quantitative except for iron(III) which shows extensive tailing. With 0.20M hydrobromic acid in 80% acetone as eluting agent, all the species above except iron(III) and copper(II) can be separated from gallium with very large separation factors. Only a 1-g resin column and small elution volumes are required to separate trace amounts and up to 0.5 mmole of gallium from more than 1 g of zinc or the other elements. Hg(II), Rh(III), Ir(IV), Se(IV), Ge(IV), As(III) and Sb(III) have not been investigated, but should be separated together with zinc according to their known distribution coefficients. Relevant elution curves, results for the analysis of synthetic mixtures and for amounts of some elements remaining in the gallium fraction are presented.  相似文献   

2.
Victor AH  Strelow FW 《Talanta》1981,28(4):207-214
Zinc and lead can be separated from Cd, Bi(III), In and V(V) by eluting these elements with 0.2M hydrochloric acid in 60% acetone from a column of AG50W-X8 cation-exchange resin, zinc and lead being retained. Mercury(II), Tl(III), As(III), Au(III), Sn(IV), Mo(VI), W(VI) and the platinum metals have not been investigated quantitatively, but from their distribution coefficients, should also be eluted. Vanadium(V), Mo(VI) and W(VI) require the presence of hydrogen peroxide. Zinc and lead can be eluted with 0.5M hydrochloric acid in 60% acetone or 0.5M hydrobromic acid in 65% acetone and determined by AAS; the alkali and alkaline-earth metal ions, Mn(II), Co, Ni, Cu(II), Fe(III), Al, Ga, Cr(III), Ti(IV), Zr, Hf, Th, Sc, Y, La and the lanthanides are retained on the column, except for a small fraction of copper eluted with zinc and lead. Separations are sharp and quantitative. The method has successfully been applied to determination of zinc and lead in three silicate rocks and a sediment.  相似文献   

3.
Strelow FW  Weinert CH 《Talanta》1973,20(11):1127-1137
U(VI) can be separated from Ga, Fe(III), Bi, Pb, Cd, Zn, Cu(II) and Au(III) by quantitative elution with 0.50M HBr in 86% acetone or with 0.35M HBr in 90% acetone from a column of AG50W-X4 cation-exchange resin of 200-400 mesh particle size. U(VI) and many other ions are retained. U(VI) then can be eluted selectively with 0.50M HCl in 83% acetone or with 0.35M HCl in 85% acetone. Co(II), Mn(II), Mg, Ca, Ti(IV), Al, Zr, Th and La are quantitatively retained by the column. These elements then can be eluted with 5M HNO(3). At the higher acid concentration (0.50M) the separation between U(VI) and Li is not satisfactory but is excellent at the lower acid concentration; the U(VI) peak is sharper at the higher acid concentration. Separations are sharp and quantitative, as is demonstrated by results for some synthetic mixtures. Distribution coefficients and elution curves are presented.  相似文献   

4.
Gold(III) can be separated from Cd, In. Zn, Ni, Cu(II), Mn(II), Co(II), Mg, Ca, Al, Fe(III), Ga and U(VI) by adsorbing these elements on a column of AG50W-X8 sulphonated polystyrene cation-exchange resin from 0.1M HCl containing 60% v v acetone, while Au(III) passes through and can be eluted with the same reagent. Separations are sharp and quantitative. The amounts of gold retained by the resin are between 1 and 2 orders of magnitude lower than encountered during adsorption from aqueous 0.1M HCl. Recoveries for mg amounts of gold are 99.9% or better and for ng amounts are still better than 99%, as shown by radioactive tracer methods. Hg(II), Bi, Sn(IV), the platinum metals and some elements which tend to form oxy-anions in dilute acid accompany gold. All other elements, though not investigated in detail, should be retained, according to their known distribution coefficients. Relevant elution curves, results of quantitative separations of binary mixtures and of recovery tests are presented.  相似文献   

5.
Strelow FW  Baxter C 《Talanta》1969,16(8):1145-1151
Tervalent rare earths and Sc are separated from the silicate-forming elements Al, Fe(III), Mg and Ti(IV), and also from Mn(II), U(VI), Be, Ga, In(III), Tl(III), Bi(III), Ni, Zn, Cu(II), Cd and Pb by cation-exchange chromatography. The other elements are eluted with 3.0 M HC1 containing 50% ethanol from a column of 60 ml of AG50W-X8 resin (200-400 mesh) while the rare earths are retained. Separation factors are larger than in aqueous hydrochloric acid. Th, Zr, Hf, Ba, Sr, Ca, K, and Rb are the only elements which accompany the rare earths group, but these can easily be separated by other methods which are described. Relevant distribution coefficients, elution curves and accurate results of quantitative separations of synthetic mixtures are presented.  相似文献   

6.
Donaldson EM  Mark E 《Talanta》1982,29(8):663-669
The chloroform extraction of 30 elements (Fe, Co, Ni, Zn, Cd, Ge, Sn, V, As, Sb, Bi, Cu, Ag, Au, Mn, Re, Ga, In, Tl, Se, Te, Cr, Mo, U, Pt, Pd, Rh, Ir, Ru and Ce) from 0.1-8M sulphuric acid in the presence of potassium ethyl xanthate has been studied. Pd(II), Bi, As(III), Sb(III), Se(IV) and Te(IV) are completely extracted and Au(III) is largely extracted over the range of acid concentration investigated. Fe(II), Tl(I), Rh(III) and Cr(VI) are only slightly extracted and Se(VI), Te(VI), Ru(III), Cr(III), Mn(II), Zn, Ce(IV), Ir(IV) and Ge(IV) are not extracted at all. Depending on the acid concentration, the remaining elements are all partly extracted. Results are compared with those obtained in an earlier study of the extraction of xanthate complexes from hydrochloric acid media. The processes involved in the formation of some xanthate complexes and potential analytical separations are discussed.  相似文献   

7.
The lanthanides plus yttrium and scandium are separated from Ba, Sr, Ca, Mg, Pb(II), Bi(III), Zn, Mn(II) and U(VI) by eluting these elements with 2.0 M nitric acid from a column of AG50W-X8 cation exchange resin (200-400 mesh). The lanthanides are retained and can then be eluted with 4 M nitric or hydrochloric acid. Separations are quantitative and applicable to microgram and millimolar amounts of the lanthanides and the other elements. Elements such as Cu(II), Co(II), Ni(II), Cd. Hg(II), T1(I). Ag, Be, Ti(IV) and the alkali metals should accompany barium quantitatively according to their known distribution coefficients. Relevant elution curves and results of analysis of synthetic mixtures are presented.  相似文献   

8.
Donaldson EM 《Talanta》1976,23(6):411-416
The chloroform extraction of 32 elements (Fe, Co, Ni, Zn, Cd, Ge, Sn, Pb, V, As, Sb, Bi, Cu, Ag, Au, Mn, Re, Ga, In, Tl, Ce, Se, Te, Cr, Mo, U, Pt, Pd, Rh, Ir, Ru and Os) from O.1-10M hydrochloric acid media in the presence of potassium ethyl xanthate has been studied. The oxidation states in which some elements react, and potential analytical separations, are discussed. Pd(II), As(III) and Se(IV) are completely extracted as ethyl xanthate complexes, Te(IV) is almost completely extracted, and Au(III) is largely extracted over the range of acid concentration investigated. Mn(II), Zn, Rh(III), Ir(IV), Ru(III), Os(IV), Cr(III), Cr(VI), Ce(III) and Ce(IV) are not extracted. Ge is partly extracted from 6-10M media as the chloro-complex. Depending on the acid concentration, the remaining elements are all partially extracted as xanthate complexes.  相似文献   

9.
Co(II), Ni(II), Mn(II), Li, Na, K, Rb, Cs, Be, Mg, Ca, Sr, Ba, Ti(IV), V(IV), Zr, Hf, Th, Al, Sc, Y, La, the lanthanides and also U(VI), which accompany copper(II) in hydrochloric acid-acetone mixtures, can be separated from copper by eluting copper(II) with 0.50 M hydrobromic acid in 85% acetone from a column of AG 50W-X8 resin, 200–400 mesh, while all these elements are retained by the column quantitatively. Separations are sharp and quantitative, as is demonstrated by results for some synthetic mixtures. Some relevant elution curves are presented.  相似文献   

10.
Lithium can be separated from sodium, beryllium and many other elements by eluting lithium with 1 M nitric acid in 80% methanol from a column of AG50W-X8 sulphonated polystyrene cation-exchange resin. The separation factor is not quite as large as that in 1 M hydrochloric acid in 80% methanol, but many elements, such as Zn, Cd, In, Pb(II), Bi(III) and Fe(III), which form chloride complexes in 1 M HCl-80% methanol are retained quantitatively together with Na, Be, Mg, Ca, Mn(II), Al, Ti(IV), U(VI), and many other elements, when 1 M HNO3-80% methanol is used for elution of lithium. A method for the accurate determination of traces of lithium in rock samples is described, and some results obtained are presented together with relevant distribution coefficients, elution curves and results for the analysis of synthetic mixtures.  相似文献   

11.
The separation of cadmium from indium, zinc and many other elements is considerably improved by eluting these elements with 0.1 M hydrobromic–0.5 M nitric acid solution from a column of AG1-X8 resin. Cadmium is retained very strongly and can be eluted with 2 M nitric acid or 1 M ammonia–0.2 M ammonium nitrate solution. Separations are sharp and quantitative and from microgram amounts up to 2 g of indium and zinc are separated from amounts of cadmium ranging from micrograms up to 100 mg on a 2-g (4.6 ml) resin column. Ga(II), Fe(III). Mn(II), Co(II), U(VI) and Ni(II) can be separated quantitatively from cadmium in the same way. The behaviour of numerous elements is discussed, with special attention to lead, and relevant elution curves and results from the analysis of synthetic mixtures are presented.  相似文献   

12.
Hualing D  Zhide H 《Talanta》1989,36(6):633-637
The ion flotation of 31 metal ions in hydrochloric/nitric acid solution with the cationic surfactant cetylpyridinium chloride was investigated. A 25-ml portion of 0.27-2.87 x 10(-4)M metal ion and 1.8-6.0 x 10(-4)M cetylpyridinium chloride solution in 0.17-3.4M acid mixture ([HCl]:[HNO(3)] = 2.4:1) was subjected to flotation in a cell, 22.5 cm high and 4.0 cm in diameter, for 5 min, with nitrogen bubbles. Ir(IV), Pt(IV), Ge(IV), Sn(IV), Bi(III), Au(III), Tl(III), Pd(II) and Sn(II) were floated from solution in 95-100% yield; Ru(III), Rh(III), Ir(III), Hg(II), Ag(I) and Tl(I) were partly floated, while Cr(VI), Ti(IV), Zr(IV), Ga(III), In(III), Fe(III), Sb(III), Al(III), Mn(II), Fe(II), Co(II), Ni(II), Cu(II), Zn(II), CD(II) and Pb(II) were floated with less than 20% yield. The flotation behaviour of these metal ions in the mixed acid system was compared with that in hydrochloric acid. The flotation is more efficient in the mixed acid system.  相似文献   

13.
Beryllium is separated from Mg, Ca, Mn(II), Fe(III), Al, Co(II). Zn. U(VI), La and Gd by elution with 2.0 M nitric acid in 70 % methanol from a column of AG50W-X8 sulphonated polystyrene cation exchanger, while the other elements are retained quantitatively. Sr, Ba, Sc, Y, the other lanthanides, Zr, Hf, Th, Ga, In, Cd and Ni(II) should also be separated according to their distribution coefficients or elution behaviour. Separations are sharp and recoveries quantitative from millimolar amounts down to 10 μg of beryllium. The separation of Ti(IV) and Cu(II) from beryllium is not satisfactory and requires rather large columns. Bi(III), Pb(II), Hg(II) and the alkali metals are eluted together with beryllium, but can be separated by other methods. Typical elution curves and results for the quantitative separation of binary synthetic mixtures are presented.  相似文献   

14.
Magnesium can be separated from calcium by elution with 3.0 M hydrochloric acid containing 60% ethanol from a column of AG50W-X8 cation-exchange resin. Calcium is retained and can be eluted with 3.0 M hydrochloric acid or 2.0 M nitric acid. The separation factor of (αMgca=5.6 is considerably higher than that in aqueous hydrochloric acid and comparable to those obtained with organic complexing reagents. Separations are sharp and quantitative; up to 10 mmol of magnesium can be separated from 0.01 mmol of calcium and vice versa on a 60-ml column. Al, Fe(III), Mn, Ni(II), Co(II), Zn, Cd, Cu(II), Pb(II), U(VI), Be, Ga, Ti(IV) in the presence of H2O2 and many other elements accompany magnesium and can be separated from calcium quantitatively. Sr, Ba, Zr, Hf, Th, Sc, La and the rare earths are retained together with Ca, but can be separated by other methods.  相似文献   

15.
The absorption behavior of Te and Sb in different oxidation states by anion exchange resins in hydrochloric acid medium has been studied. Distribution coefficients for Te(IV), Te(VI) as a function of HCl acid concentration (upto 3M HCl) have been determined. The absorbability for Sb(III) was noticed to be very high and could not be eluted out of the column using HCl as eluent. Sb(V) could be eluted quantitatively using 3M HCl. The present study clearly indicate that due to the EC/β+ decay of the parent isotopes117,118Te, the daughter nuclei117,118Sb are produced predominantly as Sb(III).  相似文献   

16.
Strelow FW 《Talanta》1980,27(9):727-732
Iron(III) can be separated from copper(II) and many other elements by eluting these from a column of AG1-X4 anion-exchange resin with 8M hydrochloric acid, while iron(III) is retained and can be eluted with 0.1M hydrochloric acid. The separation is much better than the customary one with 3.5M hydrochloric acid. Columns containing only 8.8 ml (3 g) of resin can separate traces or up to more than 1 mmole of iron(III) from more than 1 g of copper. Mn(II), Ni, Al, Mg and Ca are quantitatively eluted together with copper(II). Lead, the alkali metals, Be, Sr, Ba, Ra, Sc, Y and the lanthanides, Ti(IV), Zr, Hf, Th and Cr(III) have not been investigated in detail but should be separated according to their known distribution coefficients. Separations are sharp and quantitative, less than 1 mug of copper remaining in the iron fraction when more than 1 g was present originally. Relevant elution curves and results of the quantitative analysis of synthetic mixtures are presented.  相似文献   

17.
Kirkbright GF  Saw CG  West TS 《Talanta》1969,16(1):65-73
A study of the low-temperature fluorescence characteristics of the ions of 55 elements in concentrated hydrochloric acid is reported. The spectral characteristics, effects of hydrochloric acid concentration and time, calibration linearity and sensitivity for Sb(III), Bi, Ce(III), Pb, Te(IV), Tl(I) and Sn(IV) have been investigated. Uranium(VI), copper(I) and antimony(V) also exhibit fluorescence under these conditions. The detection limits using a commercial spectrofluorimeter with modified sample cells are Sb(III), 10(-6)M; Bi(III), 10(-8)M; Ce(III), 10(-7)M; Pb, 10(-8)M; Te(IV), 10(-7)M; Tl(I), 10(-6)M; Sn(IV), 10(-4)M. The suitability of some inorganic acid solvents for clear glass formation at -196 degrees is also investigated.  相似文献   

18.
Raychaudhuri A  Roy SK  Chakraburtty AK 《Talanta》1992,39(10):1377-1382
A simple procedure for selective sorption of tungsten is described. The method involves reduction of W(VI) to W(V) with tin(II) chloride (2%, w/v) at 8-9M hydrochloric acid, formation of the W(V)-SCN complex with 0.2M KSCN and its sorption on polyurethane foam within 20 min. The sorbed complex is then eluted with acidified acetone (1 ml of 1M hydrochloric acid and 8 ml of acetone) followed by addition of 1 ml of 0.1M KSCN to the eluent. The method has been applied to the spectrophotometric determination of tungsten in steels and silicates by measuring the absorbance of the eluted solution at 400 nm. Beer's law is obeyed for the range 0.1-12 mug W/ml. Other elements, e.g., Co(III) (50 mug/ml), Cu(II) (10 mug/ml), Ti(IV) (20 mug/ml), V(V) (10 mug/ml) and Mo(VI) (0.5 mug/ml) have no effect on the method. Interference of copper, up to 100 mug/ml has been eliminated by masking with thiourea and that due to molybdenum by prior separation with thioglycollic acid on PUF. The method has been verified with standard samples.  相似文献   

19.
Larsen RP  Oldham RD 《Talanta》1975,22(7):577-580
Plutonium can be rapidly and selectively separated from the elements that interfere in its radiochemical determination, by the use of hydrobromic acid in a hydrohalic acid anion-exchange separation procedure. Plutonium(IV) and (VI) are adsorbed onto the resin column from 9M hydrochloric acid, interfering elements such as americium and thorium are washed from the column with 9M hydrochloric acid, and the plutonium is reduced to plutoniurn(III) and washed from the column with 11M hydrobromic acid. Interfering elements such as uranium and neptunium, which are adsorbed onto the column from 9M hydrochloric acid, are retained there during the hydrochloric and hydrobromic acid washes. This system would also appear to provide the means for effectively separating plutonium from those elements that commonly interfere in such chemical methods of analysis as redox titration.  相似文献   

20.
Yatirajam V  Ram J 《Talanta》1974,21(6):439-443
A simple and selective extraction of molybdenum is described. Tungsten is masked with tartaric acid and molybdenum(VI) is reduced in 2M hydrochloric acid by boiling with hydrazine sulphate. Iron, copper and vanadium are then masked with ascorbic acid, thiourea and potassium hydrogen fluoride respectively. The molybdenum(V) is extracted as its xanthate complex into chloroform, from 1M hydrochloric acid that is 0.4M potassium ethyl xanthate. The complex is decomposed by excess of liquid bromine, and the molybdenum is stripped into alkaline hydrogen peroxide solution. The molybdenum is then determined by standard methods. Large amounts of Cu(II), Mn(II), Fe(III), Ti(IV), Zr, Ce(IV), V(V), Nb, Cr(VI), W(VI), U(VI), Re(VII) and Os(VIII) do not interfere. Several synthetic samples and ferromolybdenum have been rapidly and satisfactorily analysed by the method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号