首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 359 毫秒
1.
Due to the large absorption cross section for optical transitions into Rydberg and autoionizing states compared to non-resonant ionization, these states are of particular interest for use in efficient laser resonance ionization excitation schemes as used in Resonant Ionization Laser Ion Sources (RILIS). In order to identify these atomic states extensive laser spectroscopy has to be performed. The lasers employed at TRIUMF’s laser ion source are birefringent filter tuned titanium:sapphire (Ti:Sa) lasers which are designed for long term frequency stability rather than continuous tuning. The design and characteristics of a grating tuned, high repetition rate, pulsed Ti:Sa laser for spectroscopy applications are presented. This laser allows fast scans of up to 40 THz with a laser linewidth of approximately 6 GHz. First tests were performed by scanning across the Rydberg series of gallium.  相似文献   

2.
In this paper we present the first comprehensive study of the role of spectral phase on cross-polarized wave (XPW) generation using sub-30 femtosecond (fs) laser pulses. XPW generation improves the temporal contrast and shortens the pulse duration of fs chirped pulse amplification (CPA) lasers. For Ti:Sa lasers, compression below 30?fs is non-trivial and therefore never perfect. We therefore systematically analyze the effect of an arbitrary input spectral phase on the output spectrum and efficiency of the XPW process, both theoretically and experimentally. We derive the maximum acceptable value of residual phase for a given initial pulse duration in order to efficiently drive the XPW process for pulse shortening and contrast improvement.  相似文献   

3.
The collisional effects of a background gas on expanding ultrafast and short pulse laser ablation plumes were investigated by varying background pressure from vacuum to atmospheric pressure levels. For producing Cu ablation plumes, either 40 fs, 800 nm pulses from a Ti: Sapphire laser or 6 ns, 1,064 nm pulses from a Nd:YAG laser were used. The role of background pressure on plume hydrodynamics, spectral emission features, absolute line intensities, signal to background ratios and ablation craters was studied. Though the signal intensities were found to be maximum near to atmospheric pressure levels, the optimum signal to background ratios are observed ~20–50 Torr for both ns and fs laser ablation plumes. The differences in laser–target and laser–plasma couplings between ns and fs lasers were found to be more engraved in the crater morphologies and plasma hydrodynamic expansion features.  相似文献   

4.
We investigated the ion laser-produced plasma plume generated during ultrafast laser ablation of copper and silicon targets in high vacuum. The ablation plasma was induced by ≈50 fs, 800 nm Ti:Sa laser pulses irradiating the target surface at an angle of 45°. An ion probe was used to investigate the time-of-flight profiles of the emitted ions in a laser fluence range from the ablation threshold up to ≈10 J/cm2. The angular distribution of the ion flux and average velocity of the produced ions were studied by moving the ion probe on a circle around the ablation spot. The angular distribution of the ion flux is well described by an adiabatic and isentropic model of expansion of a plume produced by laser ablation of solid targets. The angular distribution of the ion flux narrows as the laser pulse fluence increases. Moreover, the ion average velocity reaches values of several tens of km/s, evidencing the presence of ions with kinetic energy of several hundred eV. Finally, the ion flux energy is confined in a narrow angular region around the target normal.  相似文献   

5.
We studied the evolution of wavefront aberration(WFA) of a signal beam during amplification in a Ti:sapphire chirped pulse amplification(CPA) system. The results verified that the WFA of the amplified laser beam has little relation with the change of the pump beam energies. Transverse parasitic lasing that might occur in CPA hardly affects the wavefront of the signal beam. Thermal effects were also considered in this study, and the results show that the thermal effect cumulated in multiple amplification processes also has no obvious influence on the wavefront of the signal beam for a single-shot frequency. The results presented in this paper confirmed experimentally that the amplification in a Ti:sapphire CPA system has little impact on the WFA of the signal beam and it is very helpful for wavefront correction of single-shot PW and multi-PW laser systems based on Ti:sapphire.  相似文献   

6.
The present work aimed to study the variation in the plasma parameters (temperature and density) of the Ti plasma generated by 1,064 and 532 nm lasers at different ambient N2 pressures for different delay times. The characterization of the plasma-assisted pulsed laser ablation of the titanium target is discussed. The emission spectra of the titanium plasma produced in the present study have been carefully investigated over the whole UV–NIR (200–1,000 nm) spectral range. Boltzmann plots of suitable spectral lines have been employed to derive the excitation temperature, and the electron density is derived from the Stark widths of the Ti II spectral line at 350.49 nm.  相似文献   

7.
Time-resolved optical emission spectroscopy has been successfully employed to investigate the evolution of plasma produced by the interaction of IR- and visible-pulsed laser beams with a titanium target in ambient air at atmospheric pressure. The characterization of the plasma-assisted pulsed laser ablation of the titanium target is discussed in this study. The emission spectrum produced by the titanium plasma in the wavelength range 200–1,000 nm has been carefully investigated for different experimental conditions. Boltzmann plots have been used in the calculation of the excitation temperature employing Ti II spectral lines at 286.23, 321.71, 325.29, 348.36, and 351.08 nm; this set of lines was tested and proved to be suitable for the measurement of the plasma temperature. The obtained temperature is in good agreement with the one obtained from Ti II spectral lines previously suggested by Hermann et al. [J. Appl. Phys. 77, 2928–2936, 1995, 22]. Moreover, the Stark broadening method has been employed for electron density measurements. In this study, the Stark width of the Ti II spectral line at 350.49 nm was used.  相似文献   

8.
We have developed a widely tunable deep-ultraviolet (DUV) laser in the wavelength range from 175 to 210 nm by the fourth harmonic generation of Ti:Sapphire laser. The fourth harmonic generation is performed by direct second-harmonic generation (SHG) of a frequency doubled Ti:Sapphire laser with KBBF crystal. The highest output power is 2.23 mW at 193 nm, and the power of the DUV laser is more than 1 mW from 182 nm to 210 nm. To our knowledge, it is the first demonstration of milliwatt-level widely tunable DUV all-solid-state laser below 200 nm by direct SHG technique.  相似文献   

9.
Difference frequency generation between broadband visible noncollinear optical parametric amplifier (NOPA) pulses and the fundamental pump laser pulses allows the generation of ultrashort infrared pulses with passively stabilized carrier-envelope phase. A simple prism compressor for the visible NOPA pulses is sufficient to generate few-cycle pulses in the infrared and no additional compression is needed. We theoretically investigate the concept, explain the principles, and demonstrate it for high repetition rate, long pulse durations, and various wavelengths by applying it to a Ti:sapphire and an Yb:KYW-based laser systems. For the latter sub-15 fs phase stable pulses around 1.8 μm with an energy of 100 nJ are obtained at 100 kHz repetition rate.  相似文献   

10.
The possibility of interlayer mixing in a Ti/Ta multilayer system, induced by laser irradiation, was the main purpose of these experiments. Ti/Ta multilayer system, consisting of ten alternating Ti and Ta thin films and covered by slightly thicker Ti layer, was deposited on Si (100) wafers to a total thickness of 205 nm. Laser irradiation was performed in air by picoseconds Nd:YAG laser pulses in defocused regime with fluences of 0.057 and 0.11 J cm?2. Laser beam was scanned over the 5?×?5 mm surface area with different steps along y-axes. Structural and compositional characterisation was done by auger electron spectroscopy, X-ray photoelectron spectroscopy, atomic force microscopy, and scanning electron microscopy. Laser processing at lower fluence caused only oxidation of the top Ti layer, despite of the number of applied laser pulses. Interlayer mixing was not observed. Application of laser pulses at fluence of 0.11 J cm?2 caused partial and/or complete ablation of deposited layers. In partially ablated regions considerable mixing between Ti and Ta films was registered.  相似文献   

11.
Laser-induced breakdown spectroscopy (LIBS) has proven to be extremely versatile, providing multielement analysis in real time without sample preparation. The principle is based on the ablation of a small amount of target material by interaction of a strong laser beam with a solid target. The laser must have sufficient energy to excite atoms and to ionize them to produce plasma. We aimed to improve the LIBS limit of detection (LOD) and the precision of spectral lines emitted from the produced plasma by optimizing the parameters affecting the LIBS technique. LIBS LOD is affected by many experimental parameters such as interferences, self-absorption, spectral overlap, signal-to-noise ratio, and matrix effects. The plasma in the present study is generated by focusing a 6-ns pulsed Nd–YAG laser at the fundamental wavelength of 1,064 nm onto the Al target in air at atmospheric pressure. The emission spectra are recorded using an SE 200 Echelle spectrometer manufactured by the Catalina Corporation; it is equipped with an ICCD camera type Andor model iStar DH734-18. This spectrometer allows time-resolved spectral acquisition over the whole UV-NIR (200–1,000 nm) spectral range. Calibration curves for Cu, Mg, Mn, Si, Cr, and Fe were obtained with linear regression coefficients around 99 % on the average in aluminum standard alloy samples. The determined LOD has very useful improvements for Cu I at 521.85 nm, Si I at 288.15 nm, Mn I at 482.34 nm, and Cr I at 520.84 nm spectral lines. LOD is improved by 83.8 % for Cu, 49 % for Si, 84.3 % for Mn, and 45 % for Cr lower with respect to the previous works.  相似文献   

12.
The technique of Raman conversion of sub-100 fs laser pulses based on excitation of active medium by two orthogonally polarized pulses has been developed for Raman lasers with a glass capillary. 52 fs Stokes pulse at the wavelength of 1200 nm has been generated by stimulated Raman scattering of 48 fs Ti:sapphire laser pulse at the wavelength of 800 nm in hydrogen. 13% energy conversion efficiency has been achieved at pulse repetition rate up to 2 kHz.  相似文献   

13.
变形镜对千赫兹掺钛蓝宝石飞秒激光频谱相位补偿   总被引:4,自引:2,他引:2  
尝试用光谱展宽的方法从频谱相位(而非时域相位)的角度利用变形反射镜来补偿1kHz飞秒激光系统输出光路的频谱相位畸变,从而提高飞秒激光脉冲的时域强度衬比度,改善其光束质量。频谱相位补偿实验是在一台1kHz掺钛蓝宝石飞秒激光系统输出光路中,针对超短脉冲光束通过传输介质后的频谱相位畸变,引入变形反射镜进行补偿。应用频谱相位干涉直接电场重构(SPIDER)方法和仪器作为测量手段,建立了一套相位测量补偿系统。实验结果表明用变形反射镜可使激光脉冲的相位畸变得到较好的补偿,脉冲的光束质量得到改善。这种方法的主要思想就是将相位补偿转换为空问的光程控制,控制简单且损耗很低,是自适应光学中具有应用前景的一种补偿方法。  相似文献   

14.
A 1.2 mm thick microchip cleaved from a 1.2 at.% Nd3+: BaGd2(MoO4)4 crystal was used as the laser gain medium directly. The laser cavity mirrors were coated on the microchip without cutting and polishing. In the 1.06 μm quasi-CW laser operation, the microchip was pumped by a Ti:sapphire laser with a duty cycle of 10%, the threshold is 10 mW, and the slope efficiency is 50%. In the CW laser operation pumped by a diode laser, the threshold and slope efficiency are 140 mW and 33%, respectively. The results demonstrate that the unprocessed surfaces of the cleaved microchip have good enough flatness and parallelism for laser operation.  相似文献   

15.
Applying the combination of a solid-state Ti:Sa laser system and a newly developed wide-aperture, discharge-pumped KrF amplifier, output pulses with over 9 W average power at 300 Hz have been achieved in a single output beam. The frequency-tripled seed pulses of the Ti:Sa system – delivering approximately 10 μJ energy at 248 nm – were amplified to over 30 mJ using a 3-pass off-axis amplification scheme. The optical set-up has been fitted to the amplifier’s parameters, and stored-energy measurements were carried out with different parameters in order to optimize the operational conditions of the device for the highest average power. Received: 10 June 2002 / Published online: 25 September 2002 RID="*" ID="*"Corresponding author. Fax: +49-551/503-599, E-mail: jbekesi@llg.gwdg.de  相似文献   

16.
The spectral width of a 5-kHz Ti:sapphire laser system was broadened by spectral control in a regenerative amplifier consisting of broadband chirped mirrors. The dispersion over the wide spectral range was compensated by a deformable mirror along with a genetic algorithm, resulting in a pulse width of 15 fs. The pulse width is the shortest, to our knowledge, in chirped pulse amplification systems with a regenerative amplifier. The phase distortion of broadband frequency doubling in addition to the Ti:sapphire laser was compensated by using the self-diffraction intensity in sapphire as the feedback signal into the genetic algorithm, resulting in a pulse width of 7.5 fs. The average power of the second harmonic was 1 W with a fundamental input of 7 W.  相似文献   

17.
We investigated relaxation of free charge carriers in pure crystalline diamond exposed to VUV irradiation of high order harmonics of femtosecond Ti:Sa laser in the spectral range 17–32 eV. Electron–hole pairs, possessing a significant kinetic energy, are generated in the material via direct interband transitions, relaxation of which is monitored by means of induced conductivity in the bulk and photoemission from the surface of the material. The experimental data provided by these complementary techniques are compared and discussed in terms of the competition between ionization and conductivity looking for evidences of multiplication of free charge carriers due to impact ionization. PACS 42.65.Re; 72.20.Jv; 72.40.+w; 79.60.-i  相似文献   

18.
We present a chirped pulse amplification (CPA) Ti:Sa laser generating sub-15 fs pulses with expected high temporal quality. Gain-narrowing in the pre-amplifier is balanced by a variable spectral reflectivity mirror and by a fine adaptation of the saturation conditions. A crossed polarized wave generation (XPW) filter is introduced to enhance the contrast, reduce the pulse duration and improve the spectral quality. The pulses are generated at 10 Hz repetition rate, with pulse energy of 110 μJ and very clean Gaussian spectrum. The temporal contrast is evaluated by a measurement before the XPW filter and calculations of the enhancement by the filter. The potential temporal incoherent contrast is 1012 and the coherent contrast 1010. The performance of the system makes it suitable as an injector for petawatt lasers operating in the double-CPA scheme.  相似文献   

19.
Motivated by the pulse compression challenge of novel long-cavity, high-pulse-energy Ti:sapphire laser oscillators, we report on ~280 nm supercontinuum generation and 4.5-times compression of close to transform limited, high-energy oscillator pulses using different large-mode-area photonic crystal fibers and standard chirped mirrors. As input, we used pulses of a long-cavity Ti:sapphire oscillator with 190 nJ pulse energy, 70 fs pulse length and 3.6 MHz repetition rate. Compressed pulses at the fiber/compressor output had a duration of 15–18 fs with up to 100 nJ pulse energy representing as much as 53 % throughput for the fiber/chirped mirror system. Using transform-limited input pulses, we could use short fiber pieces and thus a simple, low-dispersion chirped mirror compressor comprised of one pair of mirrors.  相似文献   

20.
用SPIDER法测量飞秒激光脉冲的光谱相位   总被引:6,自引:0,他引:6       下载免费PDF全文
介绍了用SPIDER测量光谱相位的实验装置和模拟计算飞秒激光特性参数的原理;提出了Ω 和τ等重要参数的确定方法.实验上用自建的SPIDER进行了掺钛蓝宝石飞秒振荡器输出脉 冲的相位测量,并以此为基础还原出了原输入脉冲的时域形式,模合计算所得的脉宽为107 fs,与利用二次相关法直接测量的结果十分一致. 关键词: 飞秒激光 SPIDER 光谱相位 光谱相干  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号