首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A selective molecularly imprinted solid-phase extraction (MISPE) for indomethacin (IDM) from water samples was developed. Using IDM as template molecule, acrylamide (AM) or methacrylic acid (MAA) as functional monomer, ethylene dimethacrylate (EDMA) as crosslinker, and bulk or suspension polymerization as the synthetic method, three molecularly imprinted polymers (MIPs) were synthesized and characterized with a rebinding experiment. It was found that the MIP of AM-EDMA produced by bulk polymerization showed the highest binding capacity for IDM, and so it was chosen for subsequent experiments, such as those testing the selectivity and recognition binding sites. Scatchard analysis revealed that at least two kinds of binding sites formed in the MIP, with the dissociation constants of 7.8 μmol L−1 and 127.2 μmol L−1, respectively. Besides IDM, three structurally related compounds — acemetacin, oxaprozin and ibuprofen — were employed for selectivity tests. It was observed that the MIP exhibited the highest selective rebinding to IDM. Accordingly, the MIP was used as a solid-phase extraction sorbent for the extraction and enrichment of IDM in water samples. The extraction conditions of the MISPE column for IDM were optimized to be: chloroform or water as loading solvent, chloroform with 20% acetonitrile as washing solution, and methanol as eluting solvent. Water samples with or without spiking were extracted by the MISPE column and analyzed by HPLC. No detectable IDM was observed in tap water and the content of IDM in a river water sample was found to be 1.8 ng mL−1. The extraction efficiencies of the MISPE column for IDM in spiked tap and river water were acceptable (87.2% and 83.5%, respectively), demonstrating the feasibility of the prepared MIP for IDM extraction. Figure Molecularly imprinted polymer-based solid-phase extraction for indomethacin  相似文献   

2.
A new and selective sorbent for molecularly imprinted solid-phase extraction (MISPE) was developed and applied for the determination of residues of fenitrothion (FNT) in tomatoes, using HPLC coupled to photodiode array detection (HPLC-DAD). Using FNT as the template molecule, methacrylic acid as the functional monomer, ethylene glycol dimethacrylate as the cross-linker, toluene as the porogenic solvent, and bulk polymerization as the synthetic method, a molecularly imprinted polymer (MIP) was synthesized. In order to choose the medium which promotes the best molecular recognition of FNT by the MIP, the adsorption of FNT by the MIP was studied in different media containing acetonitrile and toluene. Besides FNT, three structurally related compounds were used to evaluate the selectivity of the FNT-molecularly imprinted polymer. The MIP exhibited the highest selective rebinding to FNT. The method developed was validated, using fortified blank tomato samples. The extraction efficiency was 96%. The limits of detection and quantitation were 0.050 and 0.130 μg g−1, respectively. The intra-day precision was 5.9% and the inter-day precision 8.1%. The accuracy was higher than 89% for a concentration level around the maximum residue limit of 0.5 μg g−1.  相似文献   

3.
In order to develop more efficient preparation technologies for imprinted polymers (MIPs), the nature of pre-polymerization and molecular recognition in MIP was investigated by molecular dynamics modeling (MD), 1H NMR, FTIR and some indirect techniques. Phenol was used as the template for the study of mechanism through the analysis of hydrogen bonding, hydrophobic and π–π bonding interaction. The 4-vinylpyridine-based MIP had the highest selectivity to its phenol template. Hydrogen bonding was proved to be present by characterizing the pre-polymerization complex and evaluating the recognition process and the effects of rebinding solvents were also studied. It was found that a good rebinding solvent should have less affinity with both template and polymer, but good solubility. MD modeling and some indirect techniques demonstrated that 4-vinylpyridine-based MIP recognized phenol mainly through hydrophobic interactions when the rebinding medium was water, while hydrogen bonding was present in the recognition process when the rebinding solvent was n-hexane.  相似文献   

4.
In this work, a molecularly imprinted polymer (MIP) of morphine (MO) was prepared through thermal radical copolymerization of methacrylic acid (MAA) and ethylene glycol dimethacrylate (EDMA) in the presence of MO templates, and a molecularly imprinted sorbent assay (MIA) based on a colorimetric reporter was developed to determine the adsorption isotherm of MO-MIP binding. In practice, the MO-bound MIP was brought into contact with an aqueous mixture of Fe3+ and [Fe(CN)6]3− so that the 3-phenolic group of MO was oxidized and Fe3+ was reduced to Fe2+. As a result, the MO-bound MIP was stained with Prussian blue (PB), which was attributed to the instant co-precipitation of Fe2+ and [Fe(CN)6]3− (Ksp=10−40). Accordingly, MO-MIP binding of the blue dye could be detected by visible spectroscopy. In addition, such staining could successfully distinguish MO from codeine. Upon data analyses, a two-site binding isotherm with two dissociation constants of 6.00×10−5 and 1.03×10−3 M was found for MO-MIP binding. MIAs for non-MIP were also performed. In addition, the results of flow-system characterizations and the particle size effect are also described in this paper.  相似文献   

5.
In this work, a highly-sensitive polymeric membrane ion selective electrode for determination of tetracycline was constructed by using molecularly imprinted polymer (MIP) particles as quasi-ionophore. The water-compatible MIP particles targeting tetracycline were synthesized with tetracycline as a template molecule, methacrylic acid as a functional monomer, ethylene glycol dimethacrylate as a cross-linker, 2,2′-azobisisobutyronitrile as an initiator and lanthanum ion as a mediator. Benefited from the distinctive performance of the quasi-ionophore and the optimized composition of the membrane and the inner filling solution, the lower detection limit of the electrode was decreased to about 1 × 10−8 mol/l. It exhibited a good electrode slope 59.8 mV/decade near the theoretical Nernstian one, with a wide linear working range from 2.0 × 10−8 to 1.0 × 10−3 mol/l. Due to the specific recognition of tetracycline by the MIP particles, the selectivity coefficients for routine interferences were less than 10−4. The fabricated electrode should be used in pH 2–4, response time of which was less than 200 s when the concentration of tetracycline was higher than 1.0 × 10−6 mol/l and no more than 30 min at the concentration of 1.0 × 10−8 mol/l. Finally, the proposed highly-sensitive ion selective electrode has been successfully applied to the determination of tetracycline in aqueous samples.  相似文献   

6.
《Electroanalysis》2017,29(5):1388-1399
A molecularly imprinted polymer (MIP) was rationally synthesized with the aid of computer based studies. The computational studies were used to screen for the most suitable template to functional monomer molar ratio. Two functional monomers were involved in the study (methacrylic acid and 4‐vinylpyridine). Four MIP ratios were synthesized in accordance with the results of the computational studies and their performance was evaluated using equilibrium rebinding assays. The MIP with the best performance was used as an additive in carbon paste electrodes for the voltammetric determination of valaciclovir (VCV). Following the optimization of voltammetric parameters, a linear response was obtained in the range of 1.0x10−6–7.0x10−4 M with a limit of detection at 4.45x10−7 M. The MIP modified carbon paste electrode was successfully applied for the determination of VCV in pure solutions and dosage form.  相似文献   

7.
For desulfurization of gasoline, novel chitosan-based molecularly imprinted polymer (MIP) was prepared by cross-linking chitosan with epichlorohydrin in the presence of dibenzothiophene (DBT) as the template. The influence of cross-linking ratio on the specific adsorption was evaluated. The effects of the types and the amounts of porogen on selectivity of the chitosan MIP were also examined. Results showed that MIP has a higher recognition property to DBT. The maximum rebinding capacities of the MIP reached 22.69 mg g−1 in the model solution. The adsorption behaviors of the MIP including adsorption kinetics, isotherms, and thermodynamic parameters were investigated and the experimental data agreed well with the Langmuir model. The dynamical adsorption behaved in first-order kinetics. Negative values for the Gibbs free energy showed that the adsorptions were spontaneous processes. The MIP was further used to selectively adsorb organosulfur from gasoline.  相似文献   

8.
A photo-responsive molecularly imprinted sol–gel organic-inorganic hybrid material prepared by covalent imprinting of the template-functional monomer complex formed between 4,4′-dihydroxylazobenzene and ibuprofen was developed to explore the photo-regulated uptake and release of drug by a silicate-based smart molecularly imprinted materials. After imprinting, the template molecules (ibuprofen) were removed via hydrolysis in acid, and accurate cavities were left, which could be used as the receptor recognition sites for ibuprofen. The new organic–inorganic hybrid material shows specific affinity to ibuprofen and reversible uptake and release of ibuprofen upon alternate irradiation at 365 and 440 nm, respectively. The favorable binding strength of the imprinted receptor sites in the molecularly imprinted polymer (MIP) for ibuprofen is found to be 2.28 × 103 M−1. Density of receptor sites in the MIP material was 4.0 μmol/g—MIP.  相似文献   

9.
The synthesis and evaluation of a molecularly imprinted polymer (MIP) used as a selective solid-phase extraction sorbent and coupled to high-performance liquid chromatography (HPLC) for the efficient determination of sulfamerazine (SMR) in pond water and three fishes are reported. The polymer was prepared using SMR as the template molecule, methacrylic acid as the functional monomer and ethylene glycol dimethacrylate as the crosslinking monomer in the presence of tetrahydrofuran as the solvent. The SMR-imprinted polymers and nonimprinted polymers were characterized by FT-IR and static adsorption experiments. The prepared SMR-imprinted material showed a high adsorption capacity, significant selectivity and good site accessibility. The maximum static adsorption capacities of the SMR-imprinted and nonimprinted materials for SMR were 108.8 and 79.6 mg g−1, respectively. The relative selectivity factor of this SMR-imprinted material was 1.6. Several parameters influencing the solid-phase extraction process were optimized. Finally, the SMR-imprinted polymers were used as the sorbent in solid-phase extraction to determine SMR in pond water and three fishes with satisfactory recovery. The average recoveries of the MIP-SPE method were 94.0% in ultrapure water and 95.8% in pond water. Relative standard deviations ranging from 0.3% to 5.2% in MIP were acquired. The results for the SMR concentrations in crucian, carp and wuchang fish were 66.0, 127.1 and 51.5 ng g−1, respectively. The RSDs (n = 5) were 3.51%, 0.53% and 5.08%, respectively. The limit of detection (LOD) for SMR was 1 ng g−1 and the limit of quantitation (LOQ) was 3.5 ng g−1.  相似文献   

10.
A PVC membrane electrode for Al3+ based on glyoxal-bis-thiosemicarbazone (GBTC) as an ion carrier was developed. The electrode exhibits a Nernstian slope of 20.1 mV per decade and a linear range of 1.8 × 10−5−1.0 × 10−1 M for Al(NO3)3 with a detection limit of 8.7 × 10−6 M. It has a fast response time of about 10 s and can be used for at least 1 month. The proposed membrane sensor revealed a good selectivity for Al3+ over a wide variety of other metal ions and could be used in the pH range of 2.5–4.5. The text was submitted by the authors in English.  相似文献   

11.
A novel molecularly imprinted polymer (MIP) was prepared and used as an artificial receptor for creatinine (Cre). A sol–gel process was used to prepare the MIP. Tetraethoxysilane (TEOS) was employed as the crosslinker for the formation of a silica matrix for the MIP. Aluminum ion (Al3+) was chosen as the dopant to generate Lewis acid sites in the silica matrix for interactions with Cre. Through the sol–gel process, a polymeric matrix with memory sites for Cre was obtained, and this is mentioned here as the molecularly imprinted polymer for creatinine (MIPCre). The imprinting efficiency of MIPCre was evaluated by contrasting the adsorbed amount of Cre by MIPCre with that by the corresponding non-imprinted polymer (NIP). Creatine (Cn), N-hydroxysuccinimide (NHS), and l-tyrosine (l-tyr) were selected as interferences to study the selectivity of the MIPCre. The interference studies were also conducted using binary mixtures, such as Cre/Cn, Cre/NHS, and Cre/l-tyr. All these studies reveal that the MIPCre possess a remarkable affinity for Cre. The crucial role of Al3+ in this system is discussed in detail. Furthermore, the effects of concentrations of Al3+ and TEOS on the adsorbed amount of Cre by MIPCre were also investigated.  相似文献   

12.
A novel molecularly imprinted polymer solid-phase extraction (MISPE) with flow-injection chemiluminescence (CL) was developed for the determination of pazufloxacin mesilate (PZFX). The molecularly imprinted polymer (MIP) was synthesized by using PZFX as the imprinting molecule. A glass tube packed the particles of the MIP was employed as MISPE micro-column, which was connected into the sampling loop of the eight-way injection valve for on-line selective preconcentration and extraction of PZFX. The eluent of acetonitrile:acetic acid (9:1, v:v) was used as carrier for eluting the adsorbed PZFX to react with the mixture of cerium(IV) and sodium sulfite in the flow cell to produce strong CL. The relative intensity of CL was linear to PZFX concentration in the range from 2.5 × 10−9 to 2.5 × 10−7 g mL−1. The limit of detection was 7 × 10−10 g mL−1 (3 σ) and the relative standard deviation for 5 × 10−8 g mL−1of PZFX solution was 3.7% (n = 7). This method has been applied to the determination of PZFX in human urine.  相似文献   

13.
Guanidinoacetate methyltransferase deficiency is a recently discovered inborn defect of creatine biosynthesis which reduces serum creatinine concentrations to as low as 0.58 μg mL−1 (or 0.00058 μg mL−1 after 1,000-fold dilution). To measure ultra trace levels of creatinine in diluted samples, molecularly imprinted solid-phase extraction (MISPE) and molecularly imprinted polymer (MIP) sensor techniques have been found to be inadequate. A combination of these techniques (i.e. MISPE hyphenated with use of an MIP-sensor), reported in this paper, has been found to be highly suitable for direct assay of creatinine in highly diluted human blood serum without complicated pretreatment of the sample. The proposed technique has the potential to enhance the sensitivity of creatinine measurement from μg mL−1 to ng mL−1 in highly dilute aqueous samples in which the concentrations of interfering constituents are reduced to negligible levels. In this work the sensitivity to creatinine was found to be improved compared with that of the MIP-sensor method alone (limit of detection, LOD, 0.00149 μg mL−1). After preconcentration by MISPE and use of the sensor the detection limit for creatinine was as low as 0.00003 μg mL−1 (RSD = 0.94%, S/N = 3; 50-fold preconcentration factor) in aqueous samples.  相似文献   

14.
An anti-ketamine molecularly imprinted polymer (MIP) was synthesized and used as the sorbent in a solid-phase extraction protocol to isolate ketamine and norketamine from human hair extracts prior to LC-MS/MS analysis. Under optimised conditions, the MIP was capable of selectively rebinding ketamine, a licensed anaesthetic that is widely misused as a recreational drug, with an apparent binding capacity of 0.13 μg ketamine per mg polymer. The limit of detection (LOD) and lower limit of quantification (LLOQ) for both ketamine and norketamine were 0.1 ng/mg hair and 0.2 ng/mg hair, respectively, when 10 mg hair were analysed. The method was linear from 0.1 to 10 ng/mg hair, with correlation coefficients (R 2) of better than 0.99 for both ketamine and norketamine. Recoveries from hair samples spiked with ketamine and norketamine at a concentration of 50 ng/mg were 86% and 88%, respectively. The method showed good intra- and interday precisions (<5%) for both analytes. Minimal matrix effects were observed during the LC-MS/MS analysis of ketamine (ion suppression −6.8%) and norketamine (ion enhancement +0.2%). Results for forensic case samples demonstrated that the method successfully detected ketamine and norketamine concentrations in hair samples with analyte concentrations ranging from 0.2 to 5.7 ng/mg and from 0.1 to 1.2 ng/mg, respectively.  相似文献   

15.
A covalent interaction-based molecularly imprinted polymer (MIP) material for 3-chloro-1,2-propanediol (3-MCPD), a post-testicular anti-fertility agent and possible carcinogen and mutagen in food products containing acid-hydrolyzed vegetable proteins, has been successfully fabricated using 4-vinylphenylboronic acid as the functional monomer. Rebinding assay revealed that the binding constant, KB, for the receptor sites and non-specific sites are 1.93±0.1×104 and 2.74±0.7×102 M−1, respectively. The estimated number of receptor site, Bmax, imprinted is 123.3±3 μmol/g of MIP. The MIP material is able to act as a potentiometric chemosensor for 3-MCPD via increase in Lewis acidity of the receptor sites upon reaction of the arylboronic acid with 3-MCPD to form the more acidic arylboronic acid esters. A simple pH glass electrode is sufficient to monitor the analyte-specific rebinding. In unbuffered aqueous media, linear potentiometric response from 0 to 350 ppm of 3-MCPD can be achieved. The MIP-based chemosensing in a soya sauce matrix has also been attempted. It is found that the dynamic range of the potentiometric chemosensing response of the MIP material is much reduced, probably due to the blocking or deactivation of receptor sites by interferents in soya sauces. Nevertheless, the present work demonstrated the feasibility of using MIP-based chemosensors as semi-quantitative analytical tools for screening purposes in quality control of food products.  相似文献   

16.
In this paper, a highly selective molecularly imprinted polymer (MIP) for tramadol hydrochloride, a drug used to treat moderate to severe pain, was prepared and its use as solid-phase extraction (SPE) sorbent was demonstrated. The molecularly imprinted solid-phase extraction procedure followed by high performance liquid chromatography with ultraviolet detector (MISPE-HPLC) was developed for selective extraction and determination of tramadol in human plasma and urine. The optimal conditions for molecularly imprinted solid-phase extraction (MISPE) consisted of conditioning with 1 mL methanol and 1 mL of deionized water at neutral pH, loading of tramadol sample (50 μg L−1) at pH 7.5, washing using 1 mL acetone and elution with 3 × 1 mL of 10% (v/v) acetic acid in methanol. The MIP selectivity was evaluated by checking several substances with similar molecular structures to that of tramadol. Results from the HPLC analyses showed that the calibration curve of tramadol (using MIP from human plasma and urine) is linear in the ranges of 6–100 and 3–120 μg L−1 with good precisions (1.9% and 2.9% for 5.0 μg L−1), respectively. The recoveries for plasma and urine samples were higher than 81%.   相似文献   

17.
Micro-contact imprinting has been used to form thin-film molecular imprints of ovalbumin (OVA) in polymers supported on glass slides. Thermocalorimetric data was used to optimise the choice of functional monomer and cross-linker to maximise selectivity and minimise non-specific recognition.A polymer comprising polyethyleneglycol 400 dimethacrylate (95 vol.%) and methacrylic acid (5 vol.%) showed both maximum recognition for OVA when made as a molecularly imprinted polymer (MIP), and minimal recognition when made as a non-imprinted, i.e. control polymer. OVA rebinding to the molecularly imprinted polymer, from a buffered 2 µM OVA solution, was 1.55 × 10− 11 mol cm− 2, while the control polymer showed 10-fold less re-binding, i.e. 0.154 × 10− 11 mol cm− 2.Experiments in which human serum albumin (HSA), conalbumin, ovomucoid or lysozyme, were re-bound to the polymers, either as single proteins or in competition with OVA, showed them to have low affinity for the polymer formulation used. Of the competing proteins examined, in non-competitive binding experiments, HSA showed the greatest affinity 0.45 × 10− 11 mol cm− 2 for the OVA imprinted polymer. In two protein competition experiments, i.e. with OVA and a competing protein present at equal concentrations (2 µM), OVA binding to the OVA imprinted polymer was in all cases significantly greater than that of the competitor.  相似文献   

18.
A new post-chemiluminescence (PCL) phenomenon was observed when phenothiazine medications were injected into the reaction mixture after the chemiluminescence (CL) reaction of luminol and potassium ferricyanide had finished. A possible reaction mechanism was proposed based on studies of the kinetic characteristics of the CL, CL spectra, fluorescence spectra, and on other experiments. The feasibility of determining various phenothiazine medications by utilizing these PCL reactions was examined. A molecular imprinting–post-chemiluminescence (MI-PCL) method was established for the determination of chlorpromazine hydrochloride using a chlorpromazine hydrochloride-imprinted polymer (MIP) as the recognition material. The method displayed high selectivity and high sensitivity. The linear range of the method was 1.0×10−8∼1.0×10−6, with a linear correlation coefficient of 0.9985. The detection limit was 3×10−9 g/ml chlorpromazine hydrochloride, and the relative standard deviation for a 1.0×10−7 g/ml chlorpromazine hydrochloride solution was 4.0% (n=11). The method has been applied to the determination of chlorpromazine hydrochloride in urine and animal drinking water with satisfactory results.   相似文献   

19.
Summary A simple, selective and sensitive ion-chromatography method was investigated for simultaneously determining silicic acid, Ca2+, Mg2+, Al3+ and anions (Cl and NO 3 ) in real samples. It involved a single-column ion-chromatograph with sodium hydroxide-methanol-water eluent and conductometric detection. Cations were converted to complex anions by adding EDTA to the sample solution. A set of well-defined peaks of silicic acid, Ca2+, Mg2+, Al3+, Cl and NO 3 were obtained. Detection limits using 3.3σ (σ=standard deviation of blank solution) were 1.25×10−6 M for H3SiO 4 , 1.32×10−6 M for Ca2+, 1.28×10−6 M for Mg2+, 1.33×10−6 M for Al3+, 1.31×10−6 M for Cl and 1.24×10−6 M for NO 3 . The method was successfully applied to analysis of mineral water and composite tablets.  相似文献   

20.
An electrochemical creatinine sensor based on a molecularly imprinted polymer (MIP)‐modified sol‐gel film on graphite electrode was developed. The surface coating of MIP over sol‐gel was advantageous to obtain a porous film with outwardly exposed MIP cavities for unhindered selective rebinding of creatinine from aqueous and biological samples. A fast differential pulse, cathodic stripping voltammetric response of creatinine can be obtained after being preanodized the sensor in neutral medium containing appropriate amount of creatinine at +1.8 V versus SCE for 120 s. A linear response over creatinine concentration in the range of 1.23 to 100 μg mL?1 was exhibited with a detection limit of 0.37 μg mL?1 (S/N=3).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号