1.
Glutathione (GSH), glutathione disulfide (GSSG) and 2‐hydroxyethylated glutathione (HESG) are important biomarkers for exploring the genotoxicity mechanism of ethylene oxide (EO) or ethylene in vivo. A liquid chromatography–tandem mass spectrometry method was developed for simultaneous determination of GSH, GSSG and HESG in mouse lung tissues after inhalation exposure to EO. The lower limit of quantitation for all these biomarkers was 0.002 µg/mL. The linearity of the calibration curves for all analytes was >0.998. The intra‐day assay precision relative standard deviation (RSD) values for quality control samples for all analytes were ≤12.8% with accuracy values ranging from 87.2 to 113%. The inter‐day assay precision (RSD) values for all analytes were ≤13.1% with accuracy values ranging from 86.9 to 103%. This method was applied to concurrently determine the levels of GSH, GSSG and HESG in lung samples isolated from mouse after 4‐week inhalation exposure to EO at 0, 10, 50, 100 and 200 ppm. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

2.
A multiresidue method suitable for confirmation and determination of six sulfonamides (SAs), three tetracyclines (TCs), and pyrimethamine (PYR) in cow milk was validated. Milk samples were extracted using copolymer Oasis HLB solid-phase extraction (SPE) and analyzed by liquid chromatography-electrospray mass spectrometry with positive ion mode. Estimated method detection limits (MDL) and method quantitation limits (MQL) ranged from 0.48 to 2.64 and 0.61 to 8.64ng/mL, respectively. These values are far lower than the maximum residue limits (MRLs) established by several control authorities. Excellent linear dynamic range was observed from the method quantitation limits to 300ng/mL with correlation coefficients better than 0.9900 for all compounds. The method was accurate with recoveries ranging from 72.01 to 97.39%. Good intra-precision and intermediate precision were obtained with RSD better than 11.08%. The method is fairly robust with sample pH being the only critical control point.  相似文献   

3.
A methodology has been developed and validated for quantifying 8-hydroxydeoxyguanosine (8-OHdG) in both commercial DNA and DNA isolated from livers of male Sprague-Dawley rats by liquid chromatography/positive atmospheric pressure photoionization tandem mass spectrometry. The analytical method conditions, including conditions for stabilizing 8-OHdG during complex nuclease P1 enzymatic digestion, were also evaluated. The limit of detection for 8-OHdG was 1.0 ng/mL (17.6 fmol on-column), and the linearity of the calibration curve was greater than 0.998 from 1.0 to 500 ng/mL. The intraday assay precision relative standard deviation (RSD) value for quality control (QC) samples was < or =5.59% with accuracies ranging from 91.84 to 117.61%. The interday assay precision (RSD) value was < or =1.76% with accuracies ranging from 91.84 to 116.67%. This method, combined with the LC/UV analysis of deoxyguanosine (dG), was used for determination of the levels of 8-OHdG/10(6) dG in DNA nuclease P1 enzymatic hydrolysates from both commercial DNA and rat liver DNA.  相似文献   

4.
A sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed to determine carbocysteine in human plasma using 2-pyridylacetic acid as the internal standard (IS). The method employed derivatization with 10 M hydrochloric acid/methanol, which significantly improved the ionization efficiency of carbocysteine. After methanol-induced protein precipitation of plasma samples, carbocysteine and the IS were derivatized and subjected to LC/MS/MS analysis using atmospheric pressure chemical ionization. The method has a lower limit of quantitation of 20 ng/mL for a 0.2-mL plasma aliquot. The intra- and inter-day precision (RSD), calculated from quality control (QC) samples, was less than 7%. The accuracy, determined using QC samples, was within +/- 1%. The method offered increased sensitivity, selectivity and speed of analysis over existing methods. The method was utilized to support clinical pharmacokinetic studies of carbocysteine in volunteers following oral administration.  相似文献   

5.
A sensitive and specific method using high-performance liquid chromatography (LC)-tandem mass spectrometry (MS) for the analysis of total ribavirin in human red blood cells (RBC) is developed and validated. The method involves the addition of an internal standard and perchloric acid, the conversion of ribavirin phosphorylated metabolites to ribavirin, purification with a solid-phase exchange cartridge, and LC-MS-MS analysis. The MS-MS is selected to monitor m/z 245-113 for ribavirin and m/z 250-113 for [13C]ribavirin using positive electrospray ionization. The calibration curve is linear over a concentration of 100-10,000 ng/mL with a limit of quantitation of 100 ng/mL. Mean interassay accuracy for quality control (QC) at 100, 1000, and 10,000 ng/mL are 101.8%, 99.4%, and 98.8%, respectively. Mean interassay precision (%CV) for QC at 100, 1000, and 10,000 ng/mL are 5.0%, 5.0%, and 2.5%, respectively. Extractibility of total ribavirin from RBC is confirmed with RBC obtained from a [(14)C]ribavirin-dosed monkey. The method is used to determine the free and total ribavirin concentration in human RBC obtained from hepatitis C patients treated with ribavirin.  相似文献   

6.
A reliable and sensitive HPLC method was developed for the quantitation of tadalafil transdermal permeation through human skin. An RP column with UV detection at 290 nm was used for chromatographic separation at ambient temperature. The mobile phase was acetonitrile-water containing 20 mM pH 7 phosphate buffer (35/65, v/v) with a flow rate of 1.0 mL/min. The LOQ achieved was 1 ng/mL, and the calibration curve showed good linearity over the concentration range of 5-2000 ng/mL for tadalafil, with a determination coefficient (R2) of 0.998. The RSD values of intraday and interday analyses were all within 7%. Parameters of validation proved the precision of the method; this validated method was applied for the determination of tadalafil in transdermal permeation and drug deposition in human skin studies.  相似文献   

7.
Grastim is bacterially produced recombinant counterpart of human granulocyte colony stimulating factor (G-CSF). It has biological activity similar to that of endogenous G-CSF. In the present work a sensitive, accurate, precise and enzyme-linked immunosorbent assay (ELISA) for the quantitation of G-CSF in rat plasma was developed and validated. The ELISA method employed a technique in which anti-human-G-CSF was adsorbed onto 96-well maxisorp plates and used to capture the G-CSF in rat plasma samples. The captured G-CSF was then detected using streptavidin-HRP amplification system. Absolute recovery was >90% from rat plasma. The validation includes assessments of method accuracy and precision, range of reliable response, lower limit of quantitation (LLOQ), storage stability (30 days) in rat plasma and assay specificity. The standard curve for G-CSF was linear (R2 > 0.996) in the concentration range 4.88-625 pg/mL. The LLOQ was established at 4.88 pg/mL. The inter- and intra-day precisions in the measurement of quality control (QC) samples, 15, 250 and 500 pg/mL, were in the range 3.00-8.66% relative standard deviation (RSD) and 1.03-4.69% RSD, respectively. Accuracy in the measurement of QC samples was in the range 87.28-110.79% of the nominal values. The assay shows dilutional linearity and specificity. Stability of G-CSF was established for 30 days at -80 degrees C and through three freeze-thaw cycles. The validated assay was successfully employed for the assessment of pharmacokinetic disposition of G-CSF in rats.  相似文献   

8.
A sensitive, specific, accurate and reproducible liquid chromatography/electrospray tandem mass spectrometry method was developed and validated for the quantitation of fosinoprilat in 0.2 mL of human serum. The method employed acidification (with pH 4.0 sodium acetate buffer) of the serum samples to minimize the hydrolysis of the prodrug fosinopril to fosinoprilat prior to purification by automated 96-well solid-phase extraction. The required chromatographic separation of fosinoprilat and fosinopril was achieved isocratically on a Luna C8 analytical column (2 x 50 mm, 3 microm). The total run time was 2 min. The mobile phase contained methanol and water with 10 mM ammonium acetate. Detection was by positive ion electrospray tandem mass spectrometry. The standard curve, which ranged from 2.00 to 500 ng/mL, was fitted to a 1/x(2) weighted linear regression model. Fosinoprilat quality control (QC) samples used to determine the accuracy and precision of the method were prepared in human serum at concentrations of 5.00, 200, 400 and 1000 ng/mL. The assay accuracy was within 8% (dev). The intra- and inter-assay precisions were within 6 and 3% (RSD), respectively. Fosinopril QC samples used to gauge the rate of hydrolysis of fosinopril to fosinoprilat during the assay procedure were prepared in human serum at 500 ng/mL. The hydrolysis of fosinopril to fosinoprilat was 相似文献   

9.
A sensitive, simple, fast and rugged hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/MS) method for the determination of paroxetine was developed and validated over curve range 0.050-50 ng/mL using only 0.4 mL plasma. This is the first published LC-MS/MS method and the low limit of quantitation of this method is 10-fold lower than previously published methods. A simple liquid-liquid extraction method using methyl-tert butyl ether (MTBE) as the extraction solvent was used to extract paroxetine and the internal standard (IS) fentanyl-d(5) from plasma. The extract was evaporated to dryness, reconstituted and injected onto a silica column using a low aqueous-high organic mobile phase. The chromatographic run time was 2.0 min per injection, with retention times of 1.1 and 1.2 min for paroxetine and IS, respectively. The detection was by monitoring paroxetine at m/z 330 --> 192 and IS at m/z 342 --> 188, respectively. The inter-day precision and accuracy of the quality control (QC) samples were <5.0% relative standard deviation (RSD) and <2.9% relative error (RE). This method can be used for supporting therapeutical drug monitoring and pharmacokinetic or drug-drug interaction studies.  相似文献   

10.
A high-performance liquid chromatographic-mass spectrometric (LC/MS) assay was developed and validated for the determination of muraglitazar, a novel alpha/gamma, dual PPAR activator, in monkey plasma. The method utilized trazodone as the internal standard (IS). The extraction scheme involved a simple protein precipitation procedure with the use of a mixture of acetonitrile and methylene chloride. Separation was carried out on a BDS Hypersil C(18) analytical column (2 x 50 mm, 3 microm) and an effective chromatographic separation of muraglitazar (3.31 min) and trazadone (2.27 min) was achieved at a ssow rate of 0.3 mL/min. The mobile phase, used in an isocratic mode, consisted of 90% A (acetonitrile: 0.1% formic acid, 50:50 v/v) and 10% B (acetonitrile: 0.1% formic acid, 95:5 v/v). Detection of muraglitazar and trazodone was by positive ion turbo-ion spray mass spectrometry in the SIM mode. The mass spectrometer was programmed to admit the protonated molecules at m/z 372.0 (IS) and m/z 517.1 (muraglitazar). The standard curve, which ranged from 2 to 500 ng/mL, was fitted to a 1/x weighted linear regression model. The between run precision and within-run precision values of the assay was within 6.2% RSD. The assay accuracy was within 10.0% of the nominal values of the range of QC samples (6.0-400 ng/mL). At the lower limit of quantitation (LLQ) of 2 ng/mL, the deviation of the predicted concentrations from the nominal value of LLQ samples (n = 6) were within +/-16.6%. Muraglitazar was stable in monkey K(3)EDTA plasma for at least three freeze-thaw cycles. The processed samples (spiked samples) were stable for 48 h in auto-sampler at 10 degrees C. The average extraction recoveries of muraglitazar and IS were 83.3 and 91.9%, respectively. The assay was applied to delineate the pharmacokinetic disposition of muraglitazar in monkeys following a single oral dose.  相似文献   

11.
A single-laboratory validation by inductively coupled plasma-mass spectrometry was developed for the determination total iodine (m/z 127) in infant formula and adult nutritional products. All samples were digested in nitric acid using a closed vessel microwave oven system; Te (m/z 130) was used as an internal standard. To prevent loss of iodine, ammonium hydroxide solution was added to the samples immediately after digestion. The method quantitation limit for total iodine was 0.3 ng/mL, but a practical LOQ was used at 1.0 ng/mL, a concentration at which there was a negligible bias due to nonlinearity. The total iodine concentrations (112-1900 ng/g) in 14 out of 15 nutritional products were within specification limits. Within-day and day-to-day (6 independent days) precision values were < 10% RSD. The observed precision for the overall mean (18 independent days) of a control sample was approximately 4% RSD. In two National Institute of Standards and Technology standard reference materials, total iodine results were within certified limits. Sample spike recoveries for all 15 nutritional products were 92-105%. The data show that a conventional microwave oven digestion procedure can be used to prepare samples for iodine determination. Therefore, this technique is very compatible with other methods being proposed as modern official methods for the analysis of minerals in nutritional products.  相似文献   

12.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) assay was developed and validated to quantify a novel marine-derived depsipeptide, Aplidin, in human plasma. The method was validated to demonstrate the specificity, recovery, limit of quantitation (LOQ), accuracy, and precision of measurements. The calibration range for Aplidin was established using Aplidin standards from 0.05-50 ng/mL in blank human plasma. The multiple reaction monitoring, based on the transition m/z 1110.7 --> 295.3, was specific for Aplidin, and that based on the transition m/z 1112.6 --> 297.3 was specific for didemnin B (the internal standard); no endogenous materials interfered with the analysis of Aplidin and didemnin B from blank human plasma. The assay was linear over the concentration range 0.05-50.0 ng/mL. The correlation coefficients for the calibration curves ranged from 0.9979 to 0.9999. The mean intra- and interday accuracies for all calibration standards (n = 12) ranged from 97 to 106% (相似文献   

13.
A simple and rapid capillary zone electrophoresis method was developed for the determination of trimebutine maleate in rat plasma and tissues. Rat plasma and tissue homogenates were mixed with acetonitrile containing internal standard, ephedrine hydrochloride, and then centrifuged. The supernatant was dried under a stream of nitrogen, and the residue was reconstituted in methanol-water (1:1). The electrophoresis was performed in uncoated capillary with 30 mmol/L phosphate buffer of pH 6.0 as the separation electrolyte. The applied voltage was 10 kV and the UV detection was set at 214 nm. The peak height ratio vs concentration in plasma or homogenates was linear over the range of 5-500 ng/mL and the limit of quantitation was 5 ng/mL. The intra- and inter-day precision was RSD < 14% and <15%. The accuracy was relative error (RE) within +/- 14%. This method was applied to studying the pharmacokinetics and tissue distribution after a single dose of trimebutine maleate was administrated to the rats. The T(max), AUC, C(max) and t(1/2) were 30 min, 7.8 x 10(2) (ng/mL) min, 39 ng/mL and 1.7 x 10(2) min. The drug distribution was found in a decreasing order of liver, kidney, spleen, lung and heart.  相似文献   

14.
An ultraviolet spectrophotometric method was validated for total flavonoid quantitation, as rutin equivalents, present in the Trichilia catigua Adr. Juss (Meliaceae) and Ptychopetalum olacoides Bentham (Olacaceae) commercial extract. Parameters as linearity, interval (range), specificity, estimated limit of detection (LOD, microg/mL), estimated limit of quantitation (LOQ, microg/mL), recovery (R, %), precision or relative standard deviation (RSD, %), and accuracy (E, %) were established. The analytical method was validated according to the experimental results: correlation coefficient (r = 0.9997); interval (RSD = 0.15-0.47%; E = 98.98-101.24%); specificity to total flavonoids quantitation, as rutin equivalents, at wavelength 361.0 nm; LOD = 0.09 microg/mL and LOQ = 0.27 microg/mL; R = 99.36-102.14%; adequate intra- and interrun precision (0.30-0.49% and 0.31-0.81%), and intra- and interrun accuracy (100.60-102.38% and 98.58-100.38%).  相似文献   

15.
A rapid, sensitive and specific LC-MS-MS method has been developed for the determination of clarithromycin (CLA) in human plasma using roxithromycin (ROX) as the internal standard. Samples were prepared via liquid-liquid extraction with methyl tert-butyl ether (MTBE) and chromatographed on a Supelco RP(18) (4.6 x 50 mm, 3 microm particle size) column with a mobile phase consisting of acetonitrile:methanol:60 mM (pH 3.5) ammonium acetate buffer (32.5:32.5:35) at a constant flow rate of 0.8 mL/min. The run time was 3 min with retention times of approximately 1.65 and 1.70 min for CLA and ROX, respectively. Detection was performed on a PE Sciex API 365 mass spectrometer equipped with a turboionspray ionization source in multiple reaction monitoring (MRM) mode. The MRM pairs were m/z 748.5 --> m/z 158.2 for CLA and m/z 837.7 --> m/z 679.3 for ROX, respectively, with dwell times of 200 ms for each transition. The validated calibration curve range was 5.00-5000 ng/mL, based on 0.100 mL plasma sample volume with signal-to-noise ratio (S/N) greater than 60 for CLA at the lower limit of quantification level (5.00 ng/mL). The correlation coefficients (r(2)) of the calibration curves were better than or equal to 0.996. The inter-day (n = 18) precision and accuracy of the quality control (QC) samples were less than 3.58% RSD (relative standard deviation) and -10.8% bias, respectively. The intra-day (n = 6) precision and accuracy of the quality control samples were less than 5.0 and 12.6%, respectively. There was no significant deviation from the nominal values after a 10-fold dilution of high concentration QC samples using blank matrix. The QC samples were stable when left on the bench for 24 h or after three freeze-thaw cycles. The processed samples were also stable in HPLC autosampler at 10C for over 72 h. No matrix ionization suppression was observed when extracted blank matrix or reconstitution solvent was injected onto the system with post-column infusion of clarithromycin and roxithromycin. No carryover was observed when an extracted blank plasma sample was injected immediately after a 5000 ng/mL ULOQ (the upper limit of quantification) standard. The mean recovery was 81.5 and 78.3%, respectively, for clarithromycin and internal standard.  相似文献   

16.
A simple and sensitive procedure utilizing GC-MS for the identification and quantitation of clenbuterol in biofluids and tissues is described. This improved method utilizes trimethylboroxine for the derivatization of clenbuterol, requires only 1 mL/g of biological sample, and most importantly does not require an extra cleaning step for urine specimens prior to extraction. Linear quantitative response curves have been generated for derivatized clenbuterol over a concentration range of 5-200 ng/mL. The extraction efficiency at four representative points of the standard curve exceeded 90% in both specimen types (plasma and urine). Linear regression analyses of the standard curve in both specimen types exhibited correlation coefficients ranging from 0.997 to 1.000. The Limit of detection (LOD) and Limit of quantitation (LOQ) values for plasma specimens were determined to be 0.5 and 1.5 ng/mL respectively. For urine specimens, LOD and LOQ values were 0.2 and 0.7 ng/microL respectively. Percentage recoveries ranged from 91 to 95% for urine and 89 to 101% for plasma. Precision and accuracy (within-run and between-run) studies reflected a high level of reliability and reproducibility of the method. In addition to its reliability, sensitivity and simplicity, this modified procedure is more efficient and cost effective, requiring less time, only 1 mL of sample, and minimal amounts of extraction solvents. The applicability of the method for the detection and quantitation of clenbuterol in biological tissues of rats treated with the drug was demonstrated successfully. For comparative analysis of clenbuterol in plasma and liver samples, both GC-MS and enzyme immunoassay (EIA) methods are found to be suitable. Due to potential antibody-cross reactivity with EIA, the GC-MS method is the method of choice for most samples because of its specificity. However, the EIA method is considered the method of choice for analysis of clenbuterol found in concentrations below the limits of quantitation by GC-MS due to its sensitivity.  相似文献   

17.
A rapid and selective method based on liquid chromatography/electrospray tandem mass spectrometry (LC/ESI-MS/MS) has been developed for the direct quantitation of a methyl phosphotriester DNA adduct, thymidyl (3'-5') thymidine [dTp(Me)dT] from enzymatic hydrolysates of DNA (either in vitro DNA or in cell culture) treated with MNU (N-methyl-N-nitrosourea) or MMS (methyl methane sulfonate). The lower limit of quantitation was 2 ng/mL. Linearity of the calibration curve was greater than 0.999 from 2 to 1000 ng/mL. Intraday precision for four levels of quality controls ranged from 2.8 to 20.1%, and interday precision ranged from 2.9 to 5.6%. This method was used to quantify the levels of dTp(Me)dT in enzymatic hydrolysates of DNA obtained from a series of incubations of salmon testis DNA or mouse lymphoma cells with either MNU or MMS.  相似文献   

18.
A method described by European Union Regulation (EEC) No. 2000R2870 was validated and supported by GC/MS analysis for the determination of volatile congeners and methanol in Turkish raki. The method was validated in terms of specificity, accuracy, precision, LOD, LOQ, linearity, and robustness. The specificity of the method was demonstrated, and the method showed excellent accuracy (97.5-100.1%). Linearity was checked in the ranges of 0.200-26.390 mg/100 mL for more volatile compounds and 1.155-48.00 mg/100 mL for less volatile compounds, after concentrations found in Turkish raki were taken into account. The calibration curves of all analytes showed good linearity (R2 > 0.998). The within- and between-day precision (RSD) values of 11 analytes were in the range of 0.18-4.50%. The LOD and LOQ values were in the range of 0.014-0.362 and 0.045-1.085 mg/100 mL, respectively. The method can be used as an absolute quantification method for the determination of volatile congeners and methanol in Turkish raki and for QC.  相似文献   

19.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) assay was developed and validated to quantify a novel antineoplastic agent, PM00104, in mouse, rat, dog, and human plasma. The method was validated to demonstrate the specificity, limit of quantification (LOQ), accuracy, and precision of measurements. The calibration range for PM00104 was established using PM00104 standards from 0.01-5.0 ng/mL in blank plasma. The selected reaction monitoring (SRM), based on the m/z 692.2 --> 218.2 transition, was specific for PM00104, and that based on the m/z 697.2 --> 218.2 transition was specific for PM00104 ((13)C(2),(2)H(3)) (the internal standard, IS); no endogenous materials interfered with the analysis of PM00104 and IS from blank plasma. The assay was linear over the concentration range 0.01-5.0 ng/mL. The correlation coefficients for the calibration curves ranged from 0.9981-0.9999. The mean intra-day and inter-day accuracies for all calibration standards (n = 8) ranged from 97-105% (< or =5% bias) in human plasma, and the mean inter-day precision for all calibration standards was less than 8.5%. The mean intra- and inter-day assay accuracy for all quality control (QC) replicates in human plasma (n = 9), determined at each QC level throughout the validated runs, ranged from 96-112% (< or =12% bias) and from 102-105% (< or =5% bias), respectively. The mean intra- and inter-day assay precision was less than 15.0 and 11.8% for all QC levels, respectively. For the QC samples prepared in animal species plasma, the %CV values of the assays ranged from 1.8-8.8% in mouse plasma, from 3.7-13.8% in rat plasma, and from 3.0-7.2% in dog plasma. The assay accuracies ranged from 92-102% (< or =8% bias) for all QC levels prepared in mouse plasma; ranged from 93-106% (< or =7% bias) in rat plasma; and ranged from 95-114% (< or =14% bias) in dog plasma. The assay has been used to support preclinical pharmacokinetic and toxicokinetic studies and is currently used to measure PM00104 plasma concentrations to support clinical trials.  相似文献   

20.
A simple, sensitive and specific LC-MS/MS method for the determination of lipoic acid was developed and validated over the linearity range 5-1000 ng/mL (r2 > 0.99) with 200 microL rat plasma using rosigliatzone as an internal standard (IS). The assay procedure involved a simple one-step liquid-liquid extraction of lipoic acid and IS from plasma into ethyl acetate. The organic layer was separated and evaporated under a gentle stream of nitrogen at 40 degrees C. The residue was reconstituted in the mobile phase and injected onto a Hichrom RPB column (4.6 x 250 mm, 5 microm). Separation of lipoic acid and IS was achieved with a mobile phase consisting of 0.05 M formic acid:acetonitrile (40:60, v/v) at a flow rate of 1.0 mL/min. The API-3000 LC-MS/MS was operated under the multiple reaction monitoring mode (MRM) using the electrospray ionization technique. Positive and negative ion acquisition within the same chromatographic run was used in the present method. For lipoic acid a pseudo-molecular ion transition pair was acquired in negative polarity, whereas for IS the transition pair was acquired in positive polarity. Quantitation was determined for both analyte and IS in MRM scan mode. Absolute recovery of lipoic acid and IS was >70 and 97%, respectively. The lower limit of quantification (LLOQ) of lipoic acid was 5.0 ng/mL. The inter- and intra-day precision in the measurement of quality control (QC) samples 5, 15, 400 and 800 ng/mL were in the range 2.18-5.99% relative standard deviation (RSD) and 0.93-13.77% RSD, respectively. Accuracy in the measurement of QC samples was in the range 87.40-114.40% of the nominal values. Analyte and IS were stable in the battery of stability studies, viz. bench-top, auto-sampler and freeze-thaw cycles. Stability of lipoic acid was established for 1 month at -80 degrees C. The application of the assay to a pharmacokinetic study in rats confirmed the utility of the assay.  相似文献   