首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An inductively coupled plasma atomic emission spectrometric (ICP-AES) method was developed for speciation and simultaneous determination of Cr and As, since these two analytes are commonly determined in various water samples in order to assess their toxicity. The objective of this research was to study the speciation of Cr(III), Cr(VI) in the presence of As(III) and/or As(V) using solid phase extraction (SPE) and ICP-AES. For these measurements, four spectral lines were used for each analyte with the purpose of selecting the most appropriate for each element. Finally with the use for first time of a cation-exchange column filled with benzosulfonic acid and elution with HCl, the speciation in solutions which contained [Cr(III)?+?Cr(VI)?+?As(V)] and [Cr(III)?+?Cr(VI)?+?As(III)] was examined. It was demonstrated that the separation of the two chromium species is almost quantitative and the simultaneous determination of chromium species and total arsenic analytes is possible, with very good performance characteristics. The estimated limits of detection for Cr(III), Cr(VI), As(III) and/or As(V) were 0.9?µg?L?1, 1.1 µg?L?1, 4.7 µg?L?1 and 4.5 µg?L?1 respectively, the calculated relative standard deviations (RSDs) were 3.8%, 4.1%, 5.2% and 5.1% respectively, and finally the accuracy of the methods was estimated using a certified aqueous reference material and found to be 5.6% and 4.8% for Cr(III) and Cr(VI) respectively. The method was applied to the routine analysis of various water samples.  相似文献   

2.
Application of Dowex 50W-X8 loaded with 2-amino-benzenethiol for preconcentration of total chromium (Cr(VI) and Cr(III)) in water samples and subsequent determination by inductively coupled plasma-atomic emission spectrometry was studied. The reagent 2-amino-benzenethiol loaded onto the resin effectively reduced Cr(VI) to Cr(III) and total chromium (both Cr(VI) and Cr(III)) formed chelate complex with the reagent in the Cr(III) valence state. Experimental parameters such as preconcentration time, solution flow rates, pH, and concentration of the eluent were optimized. The method has been applied for the determination of total chromium in seawater samples in the range of 0.1–200?µg?L?1. A detection limit of 0.3?µg?L?1 was achieved, and the relative standard deviation was about 5%.  相似文献   

3.
A sensitive and simple method for determination of chromium species after separation and preconcentration by solid phase extraction (SPE) has been developed. For the determination of the total concentration of chromium in solution, Cr(VI) was efficiently reduced to Cr(III) by addition of hydroxylamine and Cr(III) was preconcentrated on a column of immobilised ferron on alumina. The adsorbed analyte was then eluted with 5?mL of hydrochloric acid and was determined by flame atomic absorption spectrometery. The speciation of chromium was affected by first passing the solution through an acidic alumina column which retained Cr(VI) and then Cr(III) was preconcentrated by immobilised ferron column and determined by FAAS. The concentration of Cr(VI) was determined from the difference of concentration of total chromium and Cr(III). The effect of pH, concentration of eluent, flow rate of sample and eluent solution, and foreign ions on the sorption of chromium (III) by immobilised ferron column was investigated. Under the optimised conditions the calibration curve was linear over the range of 2–400?µg?L?1 for 1000?mL preconcentration volume. The detection limit was 0.32?µg?L?1, the preconcentration factor was 400, and the relative standard deviation (%RSD) was 1.9% (at 10?µg?L?1; n?=?7). The method was successfully applied to the determination of chromium species in water samples and total chromium in standard alloys.  相似文献   

4.
A simple, sensitive and reliable method has been developed for separation and preconcentration of chromium (VI) from aqueous samples before determination by electrothermal atomic absorption spectrometry. The method is based on the extraction of the hydrophobic complex of chromium (VI) with ammonium pyrrolidine dithiocarbamate in the coacervates made up of decanoic acid reverse micelles in the water–tetrahydrofuran mixture. Parameters affecting the extraction efficiency of the analyte were studied and optimised. Under the optimum conditions, the linear range, enhancement factor, the limit of detection and limit of quantification were found to be 0.008–0.4 µg L?1, 127, and 1.8 ng L?1 and 6.0 ng L?1, of Cr(VI), respectively. The relative standard deviation at the concentration level of 0.1 µg L?1 Cr(VI) (n = 6) was 4.2%. Total chromium was determined after the oxidation of Cr(III) to Cr(VI) with permanganate in acidic medium. The method was successfully applied to the determination of chromium species in water and human serum samples.  相似文献   

5.
A selective, simple and fast dispersive micro solid phase extraction method using magnetic graphene oxide (GO) as an efficient sorbent has been developed for the extraction, separation and speciation analysis of chromium ions. The method is based on different adsorption behaviour of Cr(VI) and Cr(III) species onto magnetic GO in aqueous solutions which allowed the selective separation and extraction of Cr(VI) in the pH range of 2.0–3.0. The retained Cr(VI) ions by the sorbent were eluted using 0.5 mL of 0.5 mol L?1 nitric acid solution in methanol and determined by ?ame atomic absorption spectrometry. Total chromium content was determined after the oxidation of Cr(III) to Cr(VI) by potassium permanganate. All effective parameters on the performance of the extraction process were thoroughly investigated and optimised. Under the optimised conditions, the method exhibited a linear dynamic range of 0.5–50.0 µg L?1 with a detection limit of 0.1 µg L?1 and pre-concentration factor of 200. The relative standard deviations of 3.8% and 4.6% (n = 8) were obtained at 25.0 µg L?1 level of Cr(VI) for intra- and inter-day analysis, respectively. The method was successfully applied to the speciation and determination of Cr(VI) and Cr(III) in environmental water samples.  相似文献   

6.
A sensitive and selective method has been developed for the determination of chromium in water samples based on using cloud point extraction (CPE) preconcentration and determination by flame atomic absorption spectrometry (FAAS). The method is based on the complexation of Cr(III) ions with Brilliant Cresyl Blue (BCB) in the presence of non-ionic surfactant Triton X-114. Under the optimum conditions, the preconcentration of 50 mL of water sample in the presence of 0.5 g/L Triton X-114 and 1.2 × 10−5 M BCB permitted the detection of 0.42 μg/L chromium(III). The calibration graph was linear in the range of 1.5–70 μg/L, and the recovery of more than 99% was achieved. The proposed method was used in FAAS determination of Cr(III) in water samples and certified water samples. In addition, the developed CPE-FAAS method was also used for speciation of the inorganic chromium species after reduction of Cr(VI) to Cr(III) using a thiosulphate solution of 120 mg/L in the presence of Hg(II) ion as a stabilizer.  相似文献   

7.
《Analytical letters》2012,45(4):809-822
Abstract

A new method based on cloud point extraction (CPE) separation and electrothermal vaporization inductively coupled plasma optical emission spectrometry (ETV‐ICP‐OES) detection was proposed for the determination of chromium species. Thenoyltrifluoracetone (TTA) was used as both an extractant for CPE of Cr(III) and a chemical modifier for ETV‐ICP‐OES determination. When the system temperature is higher than the cloud point temperature (CPT) of the selected surfactant, Triton X‐114, the complex of Cr(III) with TTA could enter the surfactant‐rich phase, whereas the Cr(VI) remained in aqueous solutions. Thus, an in situ separation of Cr(III) and Cr(VI) could be realized. The concentrated analyte was introduced into ETV‐ICP‐OES for determination of Cr(III) after proper disposal. Cr(VI) is reduced to Cr(III) prior to determining total Cr, and its assay is based on substracting of Cr(III) from total chromium. The main factors affecting cloud point extraction and the vaporization behavior of the analyte were investigated in detail. Under the optimized conditions, the limit of detection (LOD) for Cr(III) was 0.22 µg/L by preconcentration of a 10 mL sample solution, and the relative standard deviation (RSD) was 3.8% (CCr(III)=0.5 µg/mL, n=5). The proposed method was applied to the speciation of chromium in different water samples. In order to verify the accuracy of the method, a certified reference water sample was analyzed, and the results obtained were in good agreement with certified values.  相似文献   

8.
《Analytical letters》2012,45(5-6):570-580
A rapid and sensitive method for the direct determination of hexavalent chromium in natural waters has been developed. Anion exchange chromatography was used for the fast separation of chromates from matrix anions, within 15 minutes, using a 35 mM KOH eluant. Mobile phase suppression was employed prior to direct conductivity (CD) detection, comparing two different electrolytic suppressor models and achieving a 10 times lower detection limit. Post column derivatization of Cr(VI) with diphenylcarbazide was used for further selective diode array (PDA) detection. Possible Cr(III) interference was evaluated with the addition of concentrations up to 10 mg/L of Cr(III) in a Cr(VI) positive natural water sample resulting in negligible interference. Both detection techniques gave instrumental LOD of 0.05 µg/L and method LOD of 0.08 µg/L for CD and 0.05 µg/L for PDA detection in underground water. Average repeatability and reproducibility (%RSD) was 1.3% and 5.4% for CD and 1.3% and 6.1% for PDA detection for two concentration levels. Recovery ranged from 70% to 103% for CD and from 90% to 100% for PDA. Method accuracy was additionally confirmed by analyzing positive samples with LC-ICP-MS. The method was successfully applied to the determination of Cr(VI) in several tap, spring and groundwater samples from the wider area of Asopos River, Greece. High concentrations where confirmed to the majority of the analyzed samples, revealing the serious and expanded problem of industrial pollution.  相似文献   

9.
A method is proposed and explored for speciation of Cr(III) and Cr(VI), selective extraction and preconcentration in various water samples based on dynamic and static techniques. Three newly designed alumina phases-physically adsorbed-2-pyridenecarboxyladehyde-thiosemicarbazone [Al-2PC-TSC (I–III)] were synthesised and characterised. Stability tests and application of [Al-2PC-TSC (I–III)] as inorganic ion exchangers and chelating solid sorbents for various metal ions were studied and evaluated. The distribution coefficient and separation factors of chromium species versus other interfering metal ions were determined to examine the incorporated selectivity into these alumina phases. Quantitative recovery of Cr(VI) was accomplished by [Al-2PC-TSC (I–III)] at pH = 1.0 while Cr(III) was found to be quantitatively recovered on these sorbents at pH = 7.0 with minimal or no interference between these two species under the studied buffering conditions. Selective solid phase speciation and preconcentration of Cr(III) and Cr(VI) in various real water samples were successfully performed and accomplished via a micro-column, with 200 as a preconcentration factor. Selective speciation of Cr(VI) and Cr(III) via preconcentration from seawater and industrial water samples by alumina phases in pH = 1 was found to give percentage recovery values of Cr(VI) in the range 93.5–97.3 ± 3.0–5.0% and 94.0–97.5 ± 3.0–4.0%, for seawater and industrial water samples, respectively.  相似文献   

10.
A novel method for preconcentration is described for chromium speciation at microgram per liter to sub-microgram per liter levels. It is based on selective complex formation of both Cr(VI) and Cr(III) followed by dispersive liquid–liquid microextraction and determination by microsample introduction-flame atomic absorption spectrometry. Effects influencing complex formation and extraction (such as pH, temperature, time, solvent, salinity and the amount of chelating agent) have been optimized. Enrichment factors up to 275 and 262 were obtained for Cr(VI) and total Cr, respectively. The calibration graph is linear from 0.3 to 20 µg L?1, and detection limits are 0.07 and 0.08 µg L?1 for Cr(VI) and total Cr, respectively. Relative standard deviations (RSDs) were obtained to be 2.0% for Cr(VI) and 2.6% for total Cr (n?=?7).  相似文献   

11.
Doğutan M  Filik H  Tor I 《Talanta》2003,59(5):1053-1060
A new melamine based polymeric sequestering resin was prepared for preconcentration and separation of hexavalent chromium from water, and its sequestering action was investigated. The water-insoluble, cross-linked sequestering resin was formed by reaction with bromosuccinic acid and cross-linking of melamine. The active sequestering group on the resin is NH-(Succinic acid) or salt thereof. The resulting chelating resin was characterized by infrared spectra. The newly prepared resin quantitatively retained Cr(VI) at pH 2.0-4.0 when the flow rate was maintained between 1 and 5 ml min−1. The retained Cr(VI) was instantaneously eluted with 25 ml of 0.1 M NaOH. The chromium species were determined by a flame atomic absorption spectrometer. The limits of detection for Cr(VI) and Cr(III) were found to be 5.3 and 4.2 μg l−1, respectively. The precision and accuracy of the proposed procedure was checked by the use synthetic and reference steel samples. The established preconcentration method was successfully applied to the determination and selective separation of Cr(VI) in electroplating industry wastewater. Total concentrations determined by the spectrophotometric method (110.3±0.6 g l−1 Cr(VI) and 1.2±0.3 g l−1 Cr(III)) are compared with those found by FAAS and the obtained results (110.4±1.8 g l−1 Cr(VI) and 1.4±0.5 g l−1 Cr(III)) show good agreement.  相似文献   

12.
A method for speciation of Cr(III) and Cr(VI) in real samples has been developed. Cr(VI) has been separated from Cr(III) and preconcentrated as its pyrrolidinedithiocarbamate (APDC) complex by using a column containing Amberlite XAD–2000 resin and determined by FAAS. Total chromium has also been determined by FAAS after conversion of Cr(III) to Cr(VI) by oxidation with KMnO4. Cr(III) has been calculated by subtracting Cr(VI) from the total. The effect of pH, flow‐rate, adsorption and batch capacity and effect of various metal cations and salt anions on the sorption onto the resin were investigated. The adsorption is quantitative in the pH range of 1.5–2.5, and Cr(VI) ion was desorbed by using H2SO4 in acetone. The recovery of Cr(VI) was 97 ± 4 at a 95% confidence level. The highest preconcentration factor was 80 for a 200 mL sample volume. The adsorption and batch capacity of sorbent were 7.4 and 8.0 mg g?1 Cr(VI), respectively, and loading half time was 5.0 min. The detection limit of Cr(VI) is 0.6 μg/L. The procedure has been applied to the determination and speciation of chromium in stream water, tap water, mineral spring water and spring water. Also, the proposed method was applied to total chromium preconcentration in microwave digested moss and rock samples with satisfactory results. The developed method was validated with CRM‐TMDW‐500 (Certified Reference Material Trace Metals in Drinking Water) and BCR‐CRM 144R s (Certified Reference Material Sewage Sludge, Domestic Origin) and the results obtained were in good agreement with the certified values. The relative standard deviations were below 6%.  相似文献   

13.
An adsorptive stripping voltammetric method for speciation analysis of chromium in natural water samples has been developed. Ethylenediaminetetraacetic acid (EDTA) and diethylenetriaminepentaacetic acid (DTPA) were used as complexing agents for Cr(III) present in the sample and formed as products of Cr(VI) reduction, respectively. Under optimum experimental conditions linear relations in the range from 1×10?6 to 3×10?5 mol L?1 without accumulation and from 1×10?9 to 1×10?7 at 30 s accumulation time were obtained for Cr(III) and Cr(VI), respectively. For samples in which Cr(III) concentration is higher than 1×10?6 mol L?1 the Cr(III) and Cr(VI) were determined simultaneously in one voltammetric cell. For samples in which Cr(III) concentration is below 1×10?6 mol L?1 only Cr(VI) was selectively determined in the presence of Cr(III), which did not influence the Cr(VI) signal. The determination of Cr(III) and Cr(VI) was successful with the application of the proposed procedure in the presence of common foreign ions. The presented method was applied for the speciation of chromium in spiked tap and river water samples with satisfactory results.  相似文献   

14.
Zhang N  Suleiman JS  He M  Hu B 《Talanta》2008,75(2):536-543
A new chromium(III)-imprinted 3-(2-aminoethylamino) propyltrimethoxysilane (AAPTS)-functionalized silica gel sorbent was synthesized by a surface imprinting technique and was employed as a selective solid-phase extraction material for speciation analysis of chromium in environmental water samples prior to its determination by inductively coupled plasma mass spectrometry (ICP-MS). The prepared Cr(III)-imprinted silica gel shows the selectivity coefficient of more than 700 for Cr(III) in the presence of Mn(II). The static adsorption capacity of the ion-imprinted and non-imprinted sorbent for Cr(III) were 30.5 mg g(-1) and 13.4 mg g(-1). It was also found that Cr(VI) could be adsorbed at low pH by the prepared imprinted silica gel, and this finding makes it feasible to enrich and determine Cr(VI) at low pH without adding reducing reagents. The imprinted silica gel sorbent offered a fast kinetics for the adsorption and desorption of both chromium species. Under the optimized conditions, the detection limits of 4.43 pg mL(-1) and 8.30 pg mL(-1) with the relative standard deviations (R.S.D.s) of 4.44% and 4.41% (C=0.5 ng mL(-1), n=7) for Cr(III) and Cr(VI) were obtained, respectively. The proposed method was successfully applied to the speciation of trace chromium in environmental water samples. To validate the proposed method, two certified reference materials were analyzed and the determined values were in a good agreement with the certified values. The developed method is rapid, selective, sensitive and applicable for the speciation of trace chromium in environmental water samples.  相似文献   

15.
A simple speciation, separation and enrichment method has been developed for the determination of Cr(III) and Cr(VI) ions in different samples by ion-pair solvent extraction with a β-diketone ligand, 2-(4-methoxybenzoyl)-N′-benzylidene-3-(4-methoxyphenyl)-3-oxo-N-phenyl-propono hydrazide (MBMP). Cr(III) was separated from Cr(VI) as Cr(III)-(MBMP)-perchlorate ternary ion-pair complex. The influences of various analytical parameters including pH, amount of reagent, shaking time, sample volume and ionic strength on the recovery of Cr(III) and/or Cr(VI) were investigated. Total chromium was obtained after reducing Cr(VI) to Cr(III) with NH2OH?·?HCl. Recoveries were found to be higher than 95% and the relative standard deviation (RSD) was less than 2%. The method detection limit based on 3σ criterion for Cr(III) was found to be 0.32?µg?L?1. The formed ternary ion-pair complex, Cr(III)?:?MBMP?:?2ClO4, has a molar ratio of 1?:?1?:?2. The developed method has been applied successfully to the speciation of chromium in various natural water, soil, sediment and hair samples with satisfactory results.  相似文献   

16.
A simple and sensitive method has been developed for species selective determination of chromium(III) and chromium(VI) in water by electrothermal atomic absorption spectrometry. The procedure is based on selective absorption of Cr(III) on a cellulose micro column (pH 11, 0.5 mol L(-1) NaCl). Total chromium was subsequently determined after appropriate reduction of Cr(VI) to Cr(III). Recoveries of more than 97% were found. A concentration factor of 100 was achieved. The relative standard deviations (n=10) at the 40 ng L(-1) level for chromium(III) and chromium(VI) were 2.3% and 1.8% and corresponding limits of detection (based on 36) were 1.8 ng L(-1) and 5.1 ng L(-1), respectively. No interference effects have been observed from other investigated species and the method has been successfully applied to natural water samples.  相似文献   

17.
Dissolved chromium(III) and (VI) are coprecipitated separately from sea water, and chromium in the precipitates and particulate matter is determined by thin-film x-ray fluorescence spectrometry. In combination with an ultraviolet irradiation procedure whch releases bound metals, the method provides information about the speciation of chromium in near-shore surface sea water. The ratios of labile Cr(III)/(IIO+VI) generally lie in a narrow range (0.4–0.5) as do the sums of labile Cr(III) and (VI) concentrations (0.3–0.6 μg l?1). Bound chromium is variable (0–3 μg l?1) and constitutes from 0 to 90% of total dissolved chromium. Acidification of the samples in the traditional manner for trace metal determination is shown to alter the proportion of Cr(III) to Cr(VI).  相似文献   

18.
Bağ H  Türker AR  Lale M  Tunçeli A 《Talanta》2000,51(5):895-902
A rapid, sensitive and accurate method for the separation, preconcentration and determination of Cr(III) and Cr(VI) in water samples is described. Chromium species can be separated by biosorption on Saccharomyces cerevisiae immobilized on sepiolite and determined by flame atomic absorption spectrometry (FAAS). The optimum conditions for separation and preconcentration (pH, bed height, flow rate and volume of sample solution) were evaluated. Recovery of the chromium was 96.3+/-0.2% at 95% confidence level. The breakthrough capacity of the adsorbent was found as 228 mumol g(-1) for Cr(III). The proposed method was applied successfully to the determination of Cr(III) and Cr(VI) in spiked and river water samples.  相似文献   

19.
A method for the determination of chromium(III), chromium(VI) and organicallybound chromium in sea water is reported. It is confirmed that sea water contains about 9 × 10-9 M dissolved chromium. This is shown to be divided as ca. 15% inorganic Cr(III), ca. 25% inorganic Cr(VI) and ca. 60% organically-bound chromium. It is suggested that the inconsistency of earlier results on the dominant chromium species and its concentration in sea water is largely due to the fact that organically bound chromium species were not considered.  相似文献   

20.
On-line preconcentration system for the selective, sensitive and simultaneous determination of chromium species was investigated. Dual mini-columns containing chelating resin were utilized for the speciation and preconcentration of Cr(III) and Cr(VI) in water samples. In this system, Cr(III) was collected on first column packed with iminodiacetate resin. Cr(VI) in the effluent from the first column was reduced to Cr(III), which was collected on the second column packed with iminodiacetate resin. Hydroxyammonium chloride was examined as a potential reducing agent for Cr(VI) to Cr(III).The effects of pH, sample flow rate, column length, and interfering ions on the recoveries of Cr(III) were carefully studied. Five millilitres of a sample solution was introduced into the system. The collected species were then sequentially washed by 1 M ammonium acetate, eluted by 2 M nitric acid and measured by ICP-AES. The detection limit for Cr(III) and Cr(VI) was 0.08 and 0.15 μg l−1, respectively. The total analysis time was about 9.4 min.The developed method was successfully applied to the speciation of chromium in river, tap water and wastewater samples with satisfied results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号