1.
A highly sensitive laser-induced (LIF) detection scheme for native, tryptophan- or tyrosine-containing proteins in capillary electrophoresis (CE) has been demonstrated. The 275.4 nm line from an argon-ion laser is used to excite native protein fluorescence. A limit of detection (LOD) (S/N = 2) of 1 x 10(-10) M for conalbumin represents a 140-fold improvement over earlier reports. With stacking at injection, the LOD is 3 x 10(-12) M. Linear dynamic ranges of at least 5 and 4 orders of magnitude for, respectively, tryptophan and bovine serum albumin are found. The practical performance and blueprint of an easily constructed, rugged, compact and user-friendly LIF detector for CE are shown.  相似文献   

2.
A lamp‐based fluorescence detection (Flu) system for CE was extended with a wavelength‐resolved (WR) detector to allow recording of full protein emission spectra. WRFlu was achieved using a fluorescence cell that employs optical fibres to lead excitation light from a Xe‐Hg lamp to the capillary window and protein fluorescence emission to a spectrograph equipped with a CCD. A 280 nm band pass filter etc. together with a 300 nm short pass cut‐off filter was used for excitation. A capillary cartridge was modified to hold the detection cell in a commercial CE instrument enabling WRFlu in routine CE. The performance of the WRFlu detection was evaluated and optimised using lysozyme as model protein. Based on reference spectral data, a signal‐intensity adjustment was introduced to correct for transmission losses in the detector optics that occurred for lower protein emission wavelengths. CE‐WRFlu of lysozyme was performed using BGEs of 50 mM sodium phosphate (pH 6.5 or 3.0) and a charged‐polymer coated capillary. Using the 3‐D data set, signal averaging over time and emission‐wavelength intervals was carried out to improve the S/N of emission spectra and electropherograms. The detection limit for lysozyme was 21 nM, providing sufficient sensitivity to obtain spectral information on protein impurities.  相似文献   

3.
The potential of a recently developed lamp-based fluorescence detector for the analysis of underivatised proteins by capillary electrophoresis (CE) was investigated. Fluorescence detection (Flu) was achieved using optical light guides to deliver excitation light from a Xenon–Mercury lamp to the capillary detection window and to collect fluorescence emission and lead it to a photomultiplier. The performance of the detector was evaluated by monitoring the native fluorescence of the amino acid tryptophan and the proteins α-chymotrypsinogen A, carbonic anhydrase II, lysozyme and trypsinogen upon excitation at 280 nm. The test compounds were analysed using background electrolytes (BGEs) of sodium phosphate at pH 3.0 and 11.3. The results were compared to experiments of CE with UV absorbance detection. For tryptophan, a linear fluorescence response was obtained with a dynamic range of over 4 orders of magnitude, and a limit of detection (LOD) of 6.7 nM. This LOD was a factor of 200 more favourable than UV detection at 280 nm, and a factor of 20 better than detection at low-UV wavelengths. All tested proteins showed linear fluorescence responses up to 250 μg/mL. LODs were typically in the 10–20 nM range. These LODs were a factor of 25 lower than for UV detection at 280 nm, and comparable to UV detection at low-UV wavelengths. Overall, Flu yields much more stable baselines, especially with a BGE of high pH. The applicability of CE–Flu is demonstrated by the analysis of a degraded protein mixture, and of an expired formulation of the protein drug human growth hormone, indicating that protein degradation products can be selectively detected.  相似文献   

4.
Cao L  Wang H  Zhang H 《Electrophoresis》2005,26(10):1954-1962
The analytical potential of a fluorescein analogue, 6-oxy-(N-succinimidyl acetate)-9-(2'-methoxycarbonyl) fluorescein (SAMF), for the first time synthesized in our laboratory, as a labeling reagent for the labeling and determination of amino compounds by capillary electrophoresis (CE) with laser-induced fluorescence (LIF) detection was investigated. Biogenic monoamines and amino acids were chosen as model analytes to evaluate the analytical possibilities of this approach. The derivatization conditions and separation parameters for the biogenic amines were optimized in detail. The derivatization was performed at 30 degrees C for 6 min in boric acid buffer (pH 8.0). The derivatives were baseline-separated in 15 min with 25 mM boric acid running buffer (pH 9.0), containing 24 mM SDS and 12.5% v/v acetonitrile. The concentration detection limit for biogenic amines reaches 8 x 10(-11) mol.L(-1) (signal-to-noise ratio = 3). The application of CE in the analysis of the SAMF-derivatized amino acids was also exploited. The optimal running buffer for amino acids suggested that weak acidic background electrolyte offered better separation than the basic one. The proposed method was applied to the determination of biogenic amines in three different beer samples with satisfying recoveries varying from 92.8% to 104.8%. Finally, comparison of several fluorescein-based probes for amino compounds was discussed. With good labeling reaction, excellent photostability, pH-independent fluorescence (pH 4-9), and the resultant widely suited running buffer pH, SAMF has a great prospect in the determination of amino compounds in CE.  相似文献   

5.
The separation of fatty acids derivatised with Nile Blue (NB) by CE with detection using a red light-emitting diode (LED) was examined. NB was selected as the derivatisation agent due to its high molar absorption coefficient of 76,000 M(-1) cm(-1) at 633 nm, making it well suited for sensitive absorbance detection using a red 635 nm LED. NB-labelled fatty acids were separated by both MEKC using SDS micelles, i-PrOH and n-BuOH and by NACE in a number of solvents including MeOH, EtOH and ACN. The sensitivity of NACE was superior to MEKC, with detection limits of 5x10(-7)-7x10(-7) M obtained for each acid, approximately 20 times lower than the MEKC method. The NACE detection limits are approximately 100 times lower than previous reports on the separation of fatty acids by CE using indirect absorbance detection, ten times lower than using indirect fluorescence detection and are inferior only to those obtained using precapillary derivatisation and direct fluorescence detection. The efficiency of the NACE method was also superior to MEKC and allowed the separation of unsaturated fatty acids to be examined, although it was not possible to baseline-resolve linoleic (C18:2) and linolenic (C18:3) acids in a reasonable time. The method was used to analyse the fatty acid profile of two edible oils, namely sunflower and sesame oils, after alkali hydrolysis, where it was possible to identify both the saturated and unsaturated fatty acids in each sample.  相似文献   

6.
An analytical method, based on a column coupling capillary ITP and CZE in a hydrodynamically closed separation mode hyphenated with the detection in the modular arrangement, was developed in this work. Analytical possibilities of this approach are demonstrated on the direct and ultrasensitive quantitative determination of quinine (QUI) in diluted real multicomponent ionic matrices (beverages, urine). The detection cell interface, with the rectangular arrangement of the optical channels inside, connected the separation capillary with the LIF detector via optical fibers in the on‐column detection arrangement. ITP enabled the direct large volume (30 μL) injections of the diluted real matrices with an on‐line sample pretreatment (preseparation, preconcentration) so that no external sample preparation (except for the dilution) was necessary for the separation of the analyte in the multicomponent ionic matrices. Due to the ITP sample preconcentration and intrinsic sensitivity of the LIF detection, very low concentration LOD (as low as 77 pg/mL), were reached at the same time. This was ca. two orders lower than the corresponding LOD achieved by the same 2D separation system with UV absorbance detection. Compared to the single column CE‐LIF methods applied for this model analyte and matrix, this method was found to be superior in terms of concentration LOD, with acceptable selectivity and benefits of the on‐line sample preparation. A food control and bioanalytical application clearly illustrates great practical possibilities and routine use of the proposed modular ITP–CZE–LIF technique.  相似文献   

7.
An indirect colorimetric method is presented for detection of trace amounts of hydroquinone (1), catechol (2) and pyrogallol (3). The reduction of AuCl4(-) to Gold nanoparticles (Au-NPs) by these phenolic compounds in the presence of cetyltrimethylammonium chloride (CTAC) produced very intense surface plasmon resonance peak of Au-NPs. The plasmon absorbance of Au-NPs allows the quantitative colorimetric detection of the phenolic compounds. The calibration curves derived from the changes in absorbance at lambda = 568 nm were linear with concentration of hydroquinone, catechol and pyrogallol in the range of 7.0 x 10(-7) to 1.0 x 10(-4)M, 6.0 x 10(-6) to 2.0 x 10(-4)M and 6.0 x 10(-7) to 1.0 x 10(-4)M, respectively. The detection limits were 5.3 x 10(-7), 2.5 x 10(-6) and 3.2 x 10(-7)M for the hydroquinone, catechol and pyrogallol, respectively. The method was applied satisfactorily to the determination of phenolic compounds in water samples and pharmaceutical formulations.  相似文献   

8.
A capillary electrophoresis (CE)/optical fiber light-emitting diode (LED)-induced fluorescence detection method is developed for the determination of agmatine in biological samples. The agmatine was precolumn-derivatized with fluorescence tagging reagent, fluorescein isothiocyanate (FITC). Optimal separation and determination for agmatine were obtained with an electrophoretic buffer of 20 mM sodium borate (pH 9.2). Under the optimal conditions, the determination of agmatine was achieved in less than 4 min, and the detection limit was 4.1x10(-9) M (S/N = 3). The relative standard deviation (RSD) for 11 parallel determination of agmatine was less than 3.0%. The present CE-LED induced fluorescence detection method has been applied to detect agmatine in rat brain tissue, rat stomach tissue, human serum, and human urine. The level of agmatine in human urine was quantified by CE for the first time and found to be in the range 2.5-4.1x10(-7) M.  相似文献   

9.
Based on the formation of a Keggin-type [PMo12O40]3- complex, a sensitive capillary electrophoresis (CE) method was developed for the determination of P(V) with direct UV detection at 220 nm. A mixture of alpha- and beta-Keggin-type [PMo12O40]3- complexes was readily formed in a sample solution consisting of a trace amount of P(V), 2.5 mM Mo(VI), 0.050 M p-C6H3(CH3)-2-SO3H (XSA), and 60% v/v CH3CN. When a 0.05 M HCl and 60% v/v CH3CN solution was used as a migration electrolyte, the Keggin complexes exhibited a sharp and well-defined peak in the electropherogram. The peak area was linearly dependent on the P(V) concentration in the range of 5 x 10(-7)-5 x 10(-5) M; a detection limit of 1 x 10(-7) M was achieved. In comparison with indirect UV detection, the direct UV detection is about ten times more sensitive, because the Keggin complexes possess high molar absorptivities. The developed CE method was applied to the determination of P(V) in river water, and the results were in good agreement with those obtained by ion chromatography (IC) and colorimetry (COL) based on the formation of mixed-valence heteropoly blue species.  相似文献   

10.
CE methods have been developed for the determination of taurine in pharmaceutical formulation (microemulsion) and in biological media such as sweat. The CE system with end-column pulsed amperometric detection has been found to be an interesting method in comparison with UV and fluorescence detection for its simplicity and rapidity. A gold-disk electrode of 100 mm diameter was used as the working electrode. The effects of a field decoupler at the end of the capillary, separation voltage, injection and pressure times were investigated. A detection limit of 4 x 10(-5) mol/L was reached using integrated pulsed amperometric detection, a method successfully applied to taurine analysis of the biological samples such as sweat. For taurine analysis of oil-in-water microemulsion, fluorescence detector was the favored method, the detection limit of which was 4 x 10(-11) mol/L.  相似文献   

11.
In this study, we introduced a simple and sensitive method of capillary electrophoresis with ultraviolet light-emitting diode-induced native fluorescence (UV-LEDIF) detection for the determination of isoquinoline alkaloids in extracts of Chelidonium majus L. Samples were extracted with acidic methanol and the extracts were directly analysed by CE. Simultaneous determination of protopine, chelidonine, coptisine, sanguinarine, allocryptopine, chelerythrine and stylopine was performed in 20mM phosphate buffer (pH 3.1). The baseline separation of these alkaloids was finished within 20 min. As these alkaloids have native fluorescence, they were directly detected using the commercially available UV light emitting diode without troublesome fluorescent derivatisation. Satisfactory LOD values were obtained for the studied compounds considering their appearance in natural extracts. Lower limits of detection were 0.05 μg/mL for protopine, 0.06 μg/mL for stylopine and allocryptopine, 0.07 μg/mL for chelidonine, 0.22 μg/mL for sanguinarine, 1.7 μg/mL for chelerythrine and 5.5 μg/mL for coptisine. The developed method was successfully applied to determine the contents of seven alkaloids in the aerial parts of Chelidonium majus L, which varied from 0.025 to 0.763% (w/w). Also, to demonstrate the potential of the proposed CE method, an estimation of the cytotoxic properties of selected Celandine alkaloids in a natural extract was carried out.  相似文献   

12.
This study describes the simultaneous determination of phosphonate, phosphate, and diphosphate by CE with direct UV detection, based on in-capillary complexation with Mo(VI). When a mixture of phosphonate, phosphate, and diphosphate was injected into a capillary containing 3.0 mM Mo(VI), 0.05 M malonate buffer (pH 3.0) and 45% v/v CH3CN, three well-defined peaks, due to the migration of the corresponding polyoxomolybdate anions, were separated. The respective calibration graphs were linear in the concentration range of 2 x 10(-6)-2 x 10(-4) M for phosphonate, 1 x 10(-6)-5 x 10(-5) M for phosphate, and 1 x 10(-6)-2 x 10(-4) M for diphosphate; the correlation coefficients were better than 0.9990. The present CE method is successfully applied to the simultaneous determination of phosphonate, phosphate, and diphosphate in tap water.  相似文献   

13.
An LIF detector was integrated into a CE system which uses a ball lens to focus the laser beam on the CE capillary. The detector employs an ellipsoid that is glued on the capillary window, to permit the collection of the fluorescence in the capillary. This 'trapped' fluorescence stays in the capillary because the angle of the silica/air interface is greater than the critical angle. The performance of this new detector setup is found to be identical to the collinear setup using the same ball lens. An application to the analysis of FITC-labeled IgG was optimized using a 14 cm effective length capillary. The LOD of an FITC-labeled IgG2 at an excitation wavelength of 488 nm was 150 pg/mL, which was 10 times better than the LOD recorded with slab gel silver staining. Using a tetramethylrhodamine (TAMRA)-labeled IgG2 and a 532 nm excitation wavelength the LOD is 50 pg/mL. The electropherograms of four different commercial FITC conjugates of IgG were studied. The presence of aggregates was observed in two samples while close kinetics of reduction was observed between free aggregates and high aggregates concentration samples. The integrated LIF detector provides an extremely powerful and convenient tool for antibody analysis and should be useful for therapeutic MAb control in pharmaceutical facilities.  相似文献   

14.
Wang W  Zhou L  Wang S  Luo Z  Hu Z 《Talanta》2008,74(4):1050-1055
This paper describes a micellar electrokinetic chromatography with indirect laser-induced fluorescence detection method for the simultaneous determination of adenine and guanine in DNA extracts from fungus, maize and soybean. The baseline separation was achieved within 2.5min with running buffer (pH 9.3) composed of 10mM borate, 20mM SDS, 3.0x10(-7)M fluorescein sodium as background reagent, applied voltage of 27.5kV, cartridge temperature of 25.0 degrees C. Good linearity relationships (correlation coefficients>0.9917) between the second-order derivative peak heights (RFU) and concentrations of the analytes (mgml(-1)) were obtained. The detection limits in second-order derivative electrophoregrams were 1.16x10(-3)mgml(-1) for adenine and 0.29x10(-3)mgml(-1) for guanine, respectively. The RSD data of intra-day for migration times and second-order derivative peak heights were less than 0.59 and 4.09%, respectively. This developed method was applied to the analysis of the two purines in DNA extracts with recoveries in the range of 85.3-110.2%. In this work, although the detection sensitivity was lower than that of direct LIF, yet the method has the advantages of rapidness and simplicity. And it would also extend the application range of LIF detector.  相似文献   

15.
6-Oxy-(N-succinimidyl acetate)-9-(2'-methoxycarbonyl) fluorescein, a new synthesized fluorescent reagent, was established for the first time as a label for the sensitive analysis of catecholamines (CAs) and serotonin (5-HT) by micellar electrokinetic chromatography (MEKC) with laser-induced fluorescence detection. After careful study on the derivatization conditions such as pH value, reagent concentration, temperature and reaction time, the labeling reaction was accomplished as quickly as 7 min with stable yield. The separation parameters for the CAs and 5-HT were also optimized in detail. The derivatives were baseline separated in a running buffer containing 30 mM boric acid and 15 mM sodium dodeculsulfate at pH 9.0. The detection limits ranged from 5 x 10(-10) to 2 x 10(-9) M (signal-to-noise ratio = 3). The rapid and sensitive method was also applied to the determination of the CAs and 5-HT of urine samples.  相似文献   

16.
A capillary electrophoretic (CE) method was developed for the simultaneous determination of P(V) and As(V). A Mo(VI)-ascorbic acid reagent reacted with a mixture of trace amounts of P(V) and As(V) to form the corresponding heteropoly-blue complexes in 0.05 M acetate buffer (pH 3.5). When 0.05 M malonate buffer was used as a migration buffer, the peaks due to their migrations were well separated in the electropherogram, and the pre-column complex-formation reaction was applied to the simultaneous CE determination of P(V) and As(V) with direct UV detection at 220 nm. With the proposed method, the calibration curves were linear in the concentration range of 5 x 10(-7) - 1 x 10(-4) M, with a detection limit of 1 x 10(-7) M (a signal-to-noise ratio of 3). Interference from foreign ions was also discussed.  相似文献   

17.
A universal detector based on backscatter interferometry has been developed to perform nanoliter volume refractive index measurements for on-chip sodium dodecyl sulfate (SDS) gel based (polyethylene oxide gel) separations and quantification label-free proteins. The on-chip interferometric backscatter detector (OCIBD) system consists of a simple, folded optical train based on the interaction of a laser beam with an etched channel in the shape of half cylinder in a fused-silica plate. The backscattered light from the channel takes on the form of a high-contrast interference pattern that contains information related to the bulk properties of the fluid located within the probe or detection volume of 2.32 x 10(-9) L. Depending on capillary electrophoresis (CE) injection method, the positional changes of the interference pattern extrema (fringes) allow for the quantification of unlabeled proteins at levels ranging from 11 to 310 amol (2.7 x 10(-8)mol/L) with a linear dynamic range of 2.5 decades (egg albumin). Using OCIBD microchannel-based SDS capillary gel electrophoresis (SDS/CGE), separation and detection of five label-free proteins was achieved in less than 100 seconds with detection limits ranging from 0.95 pg (1.1 x 10(-16)mol or 2.5 x 10(-7)mol/L) of calmodulin to 7.0 pg (1.0 x 10(-16)mol or 2.4 x 10(-7)mol/L) for bovine serum albumin (BSA) without signal filtering or active thermal control. This development shows that a universal detector based on backscatter interferometry can be used effectively for on-chip label-free solute analysis.  相似文献   

18.
A novel capillary electrophoretic (CE) method was developed for the determination of Ga(III). The so-called Anderson-type [GaMo6O24H6]3- complex was readily formed by the reaction of Mo(VI) with Ga(III) in 0.050 M monochloroacetate buffer (pH 2.0) and the precolumn complex-formation reaction was applied to the CE determination of Ga(III) with direct UV detection at 240 nm. The peak area was linearly dependent on the concentration of Ga(III) in the range of 5.0 x 10(-7)-5.0 x 10(-5) M. Owing to the high molar absorptivity of the Anderson anion, a detection limit of 2.0 x 10(-7) M (signal-to-noise ratio=3) was achieved. The advantage of the present method is that the presence of large excesses of Al(III) and In(III) does not cause interference.  相似文献   

19.
《Analytical letters》2012,45(4):589-602
ABSTRACT

A capillary electrophoresis based immunoassay (CEIA) for monoclonal antibody using diode laser induced fluorescence (LIF) detection was described. A direct assay for monoclonal anti-BSA in mouse serum was used as a model. BSA was labeled with Cy5 and used as the immunoreagent. The 635 nm line of a diode laser was used as the excitation source for LIF detection. The calibration curve for anti-BSA in mouse serum had a linear dynamic range of 4-40 nM. The concentration limit of detection (LOD) was 1.2 nM. Incubation time and CE conditions such as buffer concentration, pH and separation voltage were optimized, and the performances of different lasers as excitation sources were also compared.  相似文献   

20.
A capillary electrophoresis (CE) with UV absorption detection method is described for the simultaneous determination of glufosinate, glyphosate, and aminomethylphosphoric acid. The 9‐fluorenylmethyl chloroformate (FMOC‐Cl) was used for precolumn derivatization of the non‐absorbing herbicides. The three analytes were separated by CE in 9 min with 25 mM borate buffer at pH 9, followed by detection with a UV detector at 260 nm. We demonstrate how the detection limit can be enhanced by using acetonitrile‐salt mixtures. With acetonitrile‐salt mixtures, the limit of detection (LOD) was in the 10?7 M range. Linearity of more than two orders of magnitude was generally obtained. Precisions of migration times and peak areas were less than 0.9% and 7.5%, respectively. The applicabilities of the method for the analysis of ground water and lake water were examined.  相似文献   