首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 546 毫秒
1.
The quantitative determination of clenbuterol in human plasma and urine is of particular interest for various fields such as clinical and forensic research and doping controls. A simple and rapid sample preparation procedure based on liquid-liquid extraction with subsequent re-extraction followed by liquid chromatography and electrospray ionization tandem mass spectrometry allowed the determination of clenbuterol in urine and plasma at detection and quantification limits of 0.1 ng mL−1 and 0.2 ng mL−1, respectively, with recoveries ranging from 85–96%. The fast and robust nature of the assay provides a rapid and cost-effective alternative to established procedures utilizing solid-phase extraction strategies.  相似文献   

2.
Summary A method was developed for the separation and quantification of the warfare nerve agent sarin (O-isopropylmethylphosphonoflouridate), its metabolite methylphosphonic acid, the anti nerve agent drug pyridostigmine bromide (PB;3-dimethylaminocarbonyloxy-N-methyl pyridinium bromide) and its metaboliteN-methyl-3-hydroxypyridinium bromide in rat plasma and urine. The method involved using solid phase extraction and high performance liquid chromatography (HPLC) with reversed phase C18 column, and UV detection at 280 nm. The compounds were separated using gradient of 1% to 55% acetonitrile in 0.1% triflouroacetic acid water solution (pH 3.20) at flow rate of 0.9 ml/min in a period of 15 min. The retention times ranged from 4.4–12.1 min. The limits of detection were 50 ng mL−1 for PB andN-methyl-3-hydroxypyridinium bromide, and 10 μg mL−1 for sarin and methylphosphonic acid, while limits of quantitation were between 100 ng mL−1–12 μg mL−1. Average percentage recovery of five spiked samples from plasma were 84.6±8.4, 86.5±9.0, 76.4±8.5, 81.3±8.2, and from urine 78.5±7.9, 76.4±7.8, 74.4±8.4, 80.6±6.8 for sarin, methylphosphonic acid, pyridostigmine bromide andN-methyl-3-hydroxypyridinium bromide, respectively. This method was applied to analyze the above chemicals and metabolites following combined administration in rats.  相似文献   

3.
A new methodology was developed for analysis of aldehydes and ketones in fuel ethanol by high-performance liquid chromatography (HPLC) coupled to electrochemical detection. The electrochemical oxidation of 5-hydroxymethylfurfural, 2-furfuraldehyde, butyraldehyde, acetone and methyl ethyl ketone derivatized with 2,4-dinitrophenylhydrazine (DNPH) at glassy carbon electrode present a well defined wave at +0.94 V; +0.99 V; +1.29 V; +1.15 V and +1.18 V, respectively which are the basis for its determination on electrochemical detector. The carbonyl compounds derivatized were separated by a reverse-phase column under isocratic conditions with a mobile phase containing a binary mixture of methanol / LiClO4(aq) at a concentration of 1.0 × 10−3 mol L−1 (80:20 v/v) and a flow-rate of 1.1mL min−1 . The optimum potential for the electrochemical detection of aldehydes-DNPH and ketones-DNPH was +1.0 V vs. Ag/AgCl. The analytical curve of aldehydes-DNPH and ketones-DNPH presented linearity over the range 5.0 to 400.0 ng mL−1, with detection limits of 1.7 to 2.0 ng mL−1 and quantification limits from 5.0 to 6.2 ng mL−1, using injection volume of 20 μL. The proposed methodology was simple, low time-consuming (15 min/analysis) and presented analytical recovery higher than 95%.  相似文献   

4.
The aim of the present study was to develop a simple method to measure plasma levels of propafenone by liquid chromatography with a C18 reverse-phase column and fluorescence detection, without previous derivatization of the sample. Linearity was assessed in the range from 50 to 1000 ng mL−1 and had a correlation coefficient of 0.999. The inter- and intra-day coefficients of variation were below 5%. The limits of detection and quantification were 15 ng mL−1 and 50 ng mL−1, respectively. Drug levels were determined satisfactorily in two patients. A simple and reliable method was developed, especially useful in children with heart failure under treatment with propafenone.  相似文献   

5.
Summary Solid-phase extraction (SPE) was coupled at-line to capillary electrophoresis (CE) for the determination of a series of basic test compounds (i. e. tricyclic antidepressants). The analysis was performed using a non-aqueous CE buffer, which resulted in baseline separation of all test compounds. This is in marked contrast with CE using aqueous buffers where hardly any separation was obtained either with or without micelles. The SPE procedure was used to remove simultaneously most of the water from the sample, because no direct analysis of aqueous samples is possible when a non-aqueous CE buffer is used. With the present method the antidepressants can be determined in both urine and serum. Analyte detectability is increased up to 10-fold due to trace enrichment during the extraction process; the limits of detection (LODs; UV 214 nm) are 30–300 ng mL−1 in urine and 300–1000 ng mL−1 in serum. TheRSD values (n=5) of the within-day and between-day precision are below 9% and 11% respectively. Therefore, the present procedure can be used for drug monitoring.  相似文献   

6.
Summary A high-performance liquid-chromatographic method is described for the quantitative determination of the mycotoxin ochratoxin A (OTA) in human plasma. The assay involves extraction with chloroform and sodium bicarbonate then HPLC with fluorescence detection. The method was validated in terms of selectivity, recovery, linearity, precision (within-day and between-day variability), accuracy, detection and quantification limits, and the stability of OTA in plasma and treated samples. The limit of detection was 0.4 ng mL−1 of OTA in methanol, corresponding to 0.52 ng ml−1 OTA in plasma. This assay was successfully applied for the determination of OTA levels in human plasma.  相似文献   

7.
Analysis of biomarkers in exhaled breath condensate (EBC) is a non-invasive method for investigating the effects of different diseases or exposures, on the lungs and airways. N ɛ-carboxymethyllysine (CML) is an important biomarker of advanced glycation end products (AGEs). A method has been developed for simultaneous determination of CML and its precursor, the amino acid lysine, in exhaled breath condensate (EBC). After addition of labelled internal standards (d-4-CML; d-4-lysine), the EBC was concentrated by freeze-drying. Separation and detection of the analytes were performed by hydrophilic-ion liquid chromatography coupled with tandem mass-spectrometric detection (HILIC–MS–MS). The limits of quantification were 10 pg mL−1 EBC and 0.5 ng mL−1 EBC for CML and lysine, respectively. The relative standard deviation of the within-series precision was between 2.8 and 7.8% at spiked concentrations between 40 and 200 pg mL−1 for CML and between 6 and 20 ng mL−1 for lysine. Accuracy for the analytes ranged between 89.5 and 133%. The method was used for the analysis of EBC samples from ten healthy persons from the general population and ten persons receiving dialysis. CML and lysine were detected in all EBC samples with median values of 19 pg mL−1 CML and 11.9 ng mL−1 lysine in EBC of healthy persons and 25 pg mL−1 CML and 9.5 ng mL−1 lysine in EBC of dialysis patients.  相似文献   

8.
Summary A rapid and simple liquid-chromatographic method has been developed for on-line quantification of amphetamine in biological fluids. Untreated samples (20 μL) are injected directly into the chromatographic system and purified on a 20 mm×2.1 mm i.d. pre-column packed with 30 μm Hypersil C18 stationary phase. After clean-up the analyte is transferred to the analytical column (125 mm×4 mm i.d., 5 μm LiChrospher 100 RP18) for derivatization and separation using a mixture of acetonitrile and the derivatization reagent (o-phthaldialdehyde andN-acetyl-L-cysteine) as the mobile phase. The experimental conditions for on-line derivatization and resolution of the amphetamine have been optimized, and the results have been compared with those obtained by derivatizing the analyte in pre-column mode. The method described has been applied to the determination of amphetamine in plasma and urine. Good linearity and reproducibility were obtained in the 0.1–10.0 μg mL−1 concentration range, and limits of detection were 25 ng mL−1 and 10 ng mL−1 with UV and fluorescence detection, respectively. The procedure described is very simple and rapid, because no off-line manipulation of the sample is required; the total analysis time is approximately 8 min.  相似文献   

9.
Eprinomectin is a novel and potent antiparasitic animal health drug. An analytical procedure for the determination of EPR in bovine urine and feces has been developed. The urine sample was centrifuged and alkalized with ammonia following solid phase extraction. The fecal sample was extracted with acetonitrile, defatted with hexane, cleaned-up using C18 cartridge. All samples were analyzed by high performance liquid chromatography with fluorescence detection after derivatization with N-methylimidazole. The limits of detection are 0.5 ng mL−1 and 0.5 ng g−1, respectively. Fortified at 2, 10, 50, and 100 ng mL−1(ng g−1), inter-assay recoveries of EPR in cattle urine and feces were in the range of 87.9–91.5% and 78.6–86.3%, with coefficients of variation of 5.4–10.2% and 1.4–7.2%, respectively. Intra-assay mean recoveries of the analytes were 82.2–86.5% and 79.6–87.3%, with coefficients of variation of 7.8–11.5% and 6.3–7.8%, respectively. The method was used to study the excretion of eprinomectin in bovine urine and feces after subcutaneous administration at a dose of 0.5 mg kg−1.  相似文献   

10.
Summary An HPLC method was developed for determination of amoxicillin, penicillin G, penicillin V, ampicillin, oxacillin, cloxacillin, nafcillin and dicloxacillin in serum from pigs and cattle. Serum was cleaned up by solid-phase extraction (SPE), ultra-filtered and derivatised. The method was linear in the range tested up to 2000 ng mL−1 of individual penicillins in serum. Limits of detection were 11–14 ng mL−1. Mean recoveries were 90–103% in the range 20–2000 ng mL−1. The relative repeatability, standard deviation was <10% at 20 ng mL−1 level and <6% in the range 100–2000 ng mL−1.  相似文献   

11.
The routine techniques currently applied for the determination of nicotine and its major metabolites, cotinine, and trans-3′-hydroxycotinine, in biological fluids, include spectrophotometric, immunoassays, and chromatographic techniques. The aim of this study was to develop, and compare two new chromatographic methods high-performance liquid chromatography coupled to triple quadrupole mass spectrometry (HPLC-QQQ-MS/MS), and RP-HPLC enriched with chaotropic additives, which would allow reliable confirmation of tobacco smoke exposure in toxicological and epidemiological studies. The concentrations of analytes were determined in human plasma as the sample matrix. The methods were compared in terms of the linearity, accuracy, repeatability, detection and quantification limits (LOD and LOQ), and recovery. The obtained validation parameters met the ICH requirements for both proposed procedures. However, the limits of detection (LOD) were much better for HPLC-QQQ-MS/MS (0.07 ng mL−1 for trans-3′-hydroxcotinine; 0.02 ng mL−1 for cotinine; 0.04 ng mL−1 for nicotine) in comparison to the RP-HPLC-DAD enriched with chaotropic additives (1.47 ng mL−1 for trans-3′-hydroxcotinine; 1.59 ng mL−1 for cotinine; 1.50 ng mL−1 for nicotine). The extraction efficiency (%) was concentration-dependent and ranged between 96.66% and 99.39% for RP-HPLC-DAD and 76.8% to 96.4% for HPLC-QQQ-MS/MS. The usefulness of the elaborated analytical methods was checked on the example of the analysis of a blood sample taken from a tobacco smoker. The nicotine, cotinine, and trans-3′-hydroxycotinine contents in the smoker’s plasma quantified by the RP-HPLC-DAD method differed from the values measured by the HPLC-QQQ-MS/MS. However, the relative errors of measurements were smaller than 10% (6.80%, 6.72%, 2.04% respectively).  相似文献   

12.
Summary A simple, low-cost, sensitive and selective HPLC method was developed for the determination of phenazopyridine in human plasma. The method employs UV detection of phenazopyridine and of the internal Standard at 2 different wavelengths. Calibration curves were linear over a large dynamic range, i.e., within 0.05–10.0 μg mL−1 with limit of quantification of 0.05 μg mL−1, and a limit of detection of 0.01 μg mL−1.  相似文献   

13.
Protein can greatly enhance the fluorescence of curcumin (CU) in the presence of sodium dodecyl benzene sulfonate (SDBS). Experiments indicate that under the optimum conditions, the enhanced intensity of fluorescence is proportional to the concentration of proteins in the range of 0.0050–20.0 μg mL−1 for bovine serum albumin (BSA), 0.080–20.0 μg mL−1 for human serum albumin (HSA), and 0.040–28.0 μg mL−1 for egg albumin (EA). Their detection limits (S/N=3) are 1.4 ng mL−1, 20 ng mL−1, and 16 ng mL−1, respectively. The method has been satisfactorily used for the determination of proteins in actual samples. In comparison with most of fluorimetric methods, this method is quick and simple, has high sensitivity and good stability. The interaction mechanism is also studied.  相似文献   

14.
S. Tatar Ulu 《Chromatographia》2006,64(3-4):169-173
A new, simple, rapid and specific reversed-phase high-performance liquid chromatography (HPLC) method was developed and validated for the determination of fluvoxamine in pharmaceutical dosage forms. The HPLC separation was achieved on a C18 μ-Bondapack column (250 mm × 4.6 mm) using a mobile phase of acetonitrile–water (80:20, v/v) at a flow rate of 1 mL min−1. Proposed method is based on the derivatization of fluvoxamine with 1,2-naphthoquinone-4-sulphonic acid sodium salt (NQS) in borate buffer of pH 8.5 to yield a orange product. The HPLC method is based on measurement of the derivatized product using UV-visible absorbance detection at 450 nm. The method was validated for specificity, linearity, precision, accuracy, robustness. The degree of linearity of the calibration curves, the percent recoveries of fluvoxamine, the limit of detection and quantification, for the HPLC method were determined. The assay was linear over the concentration range of 45–145 ng mL−1 (r = 0.9999). Limit of detection and quantification for fluvoxamine were 15 and 50 ng mL−1, respectively. The results of the developed procedure (proposed method) for fluvoxamine content in tablets were compared with those by the official method. The method was found to be simple, specific, precise, accurate, reproducible and robust.  相似文献   

15.
Summary Eight triazine herbicides, prometon, propazine, atrazine, simazine, prometryn, ametryn, metribuzin, and cyanazine, have been extracted from human whole blood and urine samples by headspace solid-phase microextraction (SPME) with a polydimethylsiloxane-coated fiber and quantified by capillary gas chromatography with nitrogen-phosphorus detection. Extraction efficiencies for all compounds were 0.21–0.99% for whole blood, except for cyanazine (0.06%). For urine, the extraction efficiencies for prometon, propazine, atrazine, prometryn and ametryn were 13.6–38.1%, and those of simazine, metribuzin and cyanazine were 1.35–8.73%. The regression equations for the compounds extracted from whole blood were linear within the concentration ranged 0.01–1 μg (0.5 mL)−1 for prometon, propazine, atrazine, prometryn, and ametryn, and 0.02–1 μg (0.5 mL)−1 for simazine, metribuzin, and cyanazine. For urine, regression equations for all compounds were linear within the concentration range 0.005–0.25 μg mL−1. Compound detection limits were 2.8–9.0 ng (0.5 mL)−1 and 0.4–2.0 ng mL−1 for whole blood and urine, respectively. The coefficients of within-day and day-to-day variation were satisfactory for all the compounds, and not greater than 10.3 and 14.2%, respectively. Data obtained from determination of atrazine in rat whole blood after oral administration of the compound are also presented.  相似文献   

16.
A new method was developed for the simultaneous determination of lidocaine, proline and lomefloxacin in human urine by capillary electrophoresis-electrochemiluminescence detection with Ru(bpy)3 2+. Conditions of the separation and detection were investigated and optimized. It was proved that 20 mM phosphate buffer at pH 6.7 could achieve the most favorable resolution, and the high sensitivity of detection was obtained by using the detection potential at 1.15 V and 5 mM Ru(bpy)3 2+–60 mM phosphate buffer at pH 7.6 in the detection reservoir. The detection limits were 0.02 μg mL−1 for lidocaine, 0.03 μg mL−1 for proline and 0.06 μg mL−1 for lomefloxacin. Relative standard deviations of the ECL intensity and the migration time were 3.5 and 1.1% for 6 μg mL−1 lidocaine, 3.2 and 1.0% for 6 μg mL−1 proline and 3.7 and 1.2% for 6 μg mL−1 lomefloxacin, respectively. A baseline separation for lidocaine, proline and lomefloxacin was achieved within 360 s. The developed method was successfully applied to determine the amounts of lidocaine, proline and lomefloxacin in human urine. The recovery and RSD were in the range of 93.3–97.2 and 3.8–4.9%, respectively.  相似文献   

17.
A novel method for rapid HPLC-ICP-MS analysis of oxaliplatin in human urine was developed implementing a stationary HPLC phase with a particle size of 1.8 μm. The method allowed a cycle time of <1 min at a HPLC flow rate of 0.9 mL min−1. Procedural limits of detection of 0.05 μg L−1 oxaliplatin (150 fg on column) were obtained. Analysis of oxaliplatin in patient urine showed that accurate quantification of the intact drug demanded for storage at −80 °C and rapid measurement after thawing.  相似文献   

18.
A high-performance liquid chromatography–UV method for determining DCJW concentration in rat plasma was developed. The method described was applied to a pharmacokinetics study of intramuscular injection in rats. The plasma samples were deproteinized with acetonitrile in a one-step extraction. The HPLC assay was carried out using a VP-ODS column and the mobile phase consisting of acetonitrile–water (80:20, v/v) was used at a flow rate of 1.0 mL min−1 for the effective eluting DCJW. The detection of the analyte peak area was achieved by setting a UV detector at 314 nm with no interfering plasma peak. The method was fully validated with the following validation parameters: linearity range 0.06–10 μg mL−1 (r > 0.999); absolute recoveries of DCJW were 97.44–103.46% from rat plasma; limit of quantification, 0.06 μg mL−1 and limit of detection, 0.02 μg mL−1. The method was further used to determine the concentration–time profiles of DCJW in the rat plasma following intramuscular injection of DCJW solution at a dose of 1.2 mg kg−1. Maximum plasma concentration (C max) and area under the plasma concentration–time curve (AUC) for DCJW were 140.20 ng mL−1 and 2405.28 ng h mL−1.  相似文献   

19.
Multicommutation implemented with flow-through optosensors is a very promising area of research. This recent approach benefits from the advantages of both methods and results in high sensitivity, selectivity, and speed, and little waste generation. This paper reports the simultaneous determination of furosemide and triamterene, two widely used diuretics, by measurement of their native fluorescence. The system has been proved to be useful for determination of both analytes in pharmaceutical preparations and for determination of triamterene in human urine and serum. A minicolumn filled with Sephadex SPC-25 microbeads was used to achieve separation of both analytes before detection in a flow-through cell filled with the same resin. The sensor is linear in the range 50–1200 and 0.4–8 ng mL−1 with detection limits of 15 and 0.1 ng mL−1 for furosemide and triamterene, respectively.  相似文献   

20.
Summary A sensitive HPLC method with marbofloxacin (MAR) as internal standard and fluorescence detection is described for the analysis of ofloxacin (OFL) enantiomers in plasma samples. Plasma samples were prepared by adding phosphate buffer (pH 7.4, 0.1m), then extracted with trichloromethane.S-OFL,R-OFL, and the internal standard were separated on a reversed-phase column with water-methanol, 85.5∶14.5, as mobile phase. The concentrations ofS-OFL andR-OFL eluting from the column (retention times 7.5 and 8.7 min, respectively) were monitored by fluorescence detection withλ ex = 331 andλ em = 488 nm. The detection and quantitation limits were 10 and 20 ng mL−1, respectively, forS-OFL and 11 and 21 ng mL−1 forR-OFL. Response was linearly related to concentration in the range 10 to 2500 ng mL−1. Recovery was close to 93% for both compounds. The method was applied to determination of the enantiomers of OFL in plasma samples collected during pharmacokinetic studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号