首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An application of the direct coupling of solid-phase microextraction (SPME) with mass spectrometry (MS), a technique known as fiber introduction mass spectrometry (FIMS), is described to determine organochlorine (OCP) and organophosphorus (OPP) pesticides in herbal infusions of Passiflora L. A new fiber coated with a composite of poly(dimethylsiloxane) and poly(vinyl alcohol) (PDMS/PVA) was used. Sensitive, selective, simple and simultaneous quantification of several OCP and OPP was achieved by monitoring diagnostic fragment ions of m/z 266 (chlorothalonil), m/z 195 (alpha-endosulfan), m/z 278 (fenthion), m/z 263 (methyl parathion) and m/z 173 (malathion). Simple headspace SPME extraction (25 min) and fast FIMS detection (less than 40 s) of OCP and OPP from a highly complex herbal matrix provided good linearity with correlation coefficients of 0.991-0.999 for concentrations ranging from 10 to 140 ng ml(-1) of each compound. Good accuracy (80 to 110%), precision (0.6-14.9%) and low limits of detection (0.3-3.9 ng ml(-1)) were also obtained. Even after 400 desorption cycles inside the ionization source of the mass spectrometer, no visible degradation of the novel PDMS/PVA fiber was detected, confirming its suitability for FIMS. Fast (ca 20 s) pesticide desorption occurs for the PDMS/PVA fiber owing to the small thickness of the film and its reduced water sorption.  相似文献   

2.
Fiber introduction mass spectrometry (FIMS)-a direct coupling of SPME and MS-using selective ion monitoring (SIM) was used to detect and quantify dimethylphthalate (DMP), diethylphthalate (DEP) and dipropylphthalate (DPP) in mineral water. In FIMS, a chromatographic silicone septum is the only barrier between ambient and the high-vacuum mass spectrometer, permitting direct introduction of the SPME fiber into the ionization region of the equipment. After their thermal desorption and ionization and dissociation, the extracted phthalates are detected and quantitated by MS. Three types of SPME fibers were screened for best analyte sorption/desorption behaviors: 100 microm polydimethylsiloxane (PDMS), 65 microm polydimethylsiloxane/divinylbenzene (PDMS/DVB) and 65 microm Carbowax/divinylbenzene (CW/DVB). The PDMS/DVB and CW/DVB fibers were then evaluated for precision, and quantitative figures of merit were assessed for extractions using the PDMS/DVB fiber, which displayed the best overall performance. FIMS with the PDMS/DVB fiber allows simple extraction and MS detection and quantitation of DMP in water with good linearity and precision, and at concentrations as low as 3.6 microg L(-1). The LD and LQ of FIMS are below the maximum phthalate concentration allowed by the USEPA for drinking water (6 microg L(-1)).  相似文献   

3.
A simple and environmentally friendly methodology for headspace solid-phase microextraction (HS-SPME) using a new fiber coated with polydimethylsiloxane-poly(vinyl alcohol) (PDMS/PVA) is reported for the trace determination of organochlorine (OCP) and organophosphorus (OPP) pesticides in herbal infusions of Passiflora L. by GC-ECD. The capacity of the PDMS/PVA coating for the pesticides was compared to that of commercial PDMS fibers, with advantageous results. The effects of parameters such as the sample ionic strength, dilution of the infusion, extraction temperature and time were investigated. The optimized conditions for the determination of OCP and OPP in Passiflora L. infusions were extraction time and temperature, respectively, of 38 min and 67.5 degrees C, with 5 min of sample/headspace equilibration time. The analytical curves for the range between 0.04 ng mL(-1) to 6 ng mL(-1) of each compound presented a good quality (correlation coefficients of 0.921 or better). The detection limits for the OCP and OPP in these matrices varied from 0.01 ng mL(-1) (beta-endosulfan) to 1.5 ng mL(-1) (malathion). The sensitivity of studied methodology was adequate, as well as its accuracy (78.7-91.5%) and precision (R.S.D. = 1.2-14.2%).  相似文献   

4.
Solid phase micro-extraction in a miniature ion trap mass spectrometer   总被引:1,自引:0,他引:1  
Fiber introduction mass spectrometry (FIMS), a variation of solid-phase microextraction (SPME) and membrane introduction mass spectrometry (MIMS), is employed with a miniature mass spectrometer. The inlet system, constructed of commercially available vacuum parts, allows the direct introduction of the SPME needle vacuum chamber into the mass spectrometer. Thermal desorption of the analyte from the poly(dimethylsiloxane) (PDMS) coated fiber was achieved with a built in nichrome heater, followed by electron ionization of the analytes internal to the cylindrical ion trap (CIT). The system has been tested with several volatile organic compounds (VOC) in air and to analyze the headspace over aqueous solutions, with limits of detection in the low ppb range. The signal rise (10-90%) and fall (90-10%) times for the system ranged from 0.1 to 1 s (rise) and 1.2 to 6 s (fall) using heated desorption. In addition, this method has been applied to quantitation of toluene in benzene, toluene, xylene (BTX) mixtures in water and gasoline. This simple and rapid analysis method, coupled to a portable mass spectrometer, has been shown to provide a robust, simple, rapid, reproducible, accurate and sensitive (low ppb range) fieldable approach to the effective in situ analysis of VOC in various matrices.  相似文献   

5.
The use of two modes for mass spectrometry (MS) detection with an ion trap instrument, selected ion storage (SIS) and tandem mass spectrometry (MS/MS), are compared for the solid-phase microextraction (SPME)–gas chromatography (GC) coupled to mass spectrometry (GC-MS) determination of 16 priority organochlorine pesticides (OCPs) in drinking water samples at the ultratrace levels (ng?L?1) required by official guidelines in the European legislation. Experimental parameters investigated for the SPME sample preparation were: the type of coating (100?µm polydimethylsiloxane, PDMS, and 65?µm poly(dimethylsiloxane)–divinylbenzene, PDMS/DVB), SPME modality, extraction and desorption times and desorption temperature and the methanol percentage in the SPME working solution. Under the calculated optimal conditions two methodologies were developed, one for SIS and the other for MS/MS modes. The detection limits, precision and accuracy were evaluated for both alternatives and were appropriate to the official guidelines requirements. The SPME–GC-MS(SIS) methodology offered LODs from 0.2–6.6?ng?L?1, precision below 13% and recoveries between 83 and 110%. The SPME–GC–MS/MS methodology provided limits of detection (LODs) ranging from 0.3 to 7.6 ng?L?1, % RSD were ≤14% and recoveries of 79–108% were achieved. After the results observed within an Interlaboratory Exercise, the latest MS methodology was selected for the pursued analysis in real drinking water samples. Also, the good results in this round-robin exercise validate the proposed SPME–GC–MS/MS methodology.  相似文献   

6.
Solid phase microextraction (SPME) of chlorophenols [2-chlorophenol (2CP), 2,4-dichlorophenol (24CP), 4-chloro-3-methylphenol (43CP), 2,4,6-tri-chlorophenol (246CP) and pentachlorophenol (PCP)] followed by direct mass spectrometric analysis has been performed by fiber introduction mass spectrometry (FIMS). Two SPME fibers (65 μm PDMS/DVB and 85 μm PA fibers) were tested, and FIMS was performed via selective ion monitoring (SIM). The extractions were evaluated at 10% ionic strength and pH 1. Best extraction times were determined for both fibers. Limits of detection (LOD) and limits of quantification (LOQ) for both fibers were in the low μg L−1 range. Coefficients of correlation for the analytical curves showed linear responses and mineral water and river water samples spiked with 50 μg L−1 presented high recoveries. FIMS, as compared to current EPA methods, is demonstrated to allow faster and simpler (elimination of pre-separation or derivatization steps) analysis of chlorophenols in water with the required sensitivity.  相似文献   

7.
Solid‐phase microextraction (SPME) has been directly coupled to an ion‐trap mass spectrometer (MS) for the determination of the model compound lidocaine in urine, hereby applying MS/MS [fragmentation of [M + H]+ (m/z 235) to a fragment with m/z 86]. The throughput of samples has been increased using non‐equilibrium SPME with polydimethylsiloxane (PDMS) fibers. The effect of temperature on the sorption and the desorption was studied. Elevated temperatures during sorption (65°C) and desorption (55°C) had a considerable influence on the speed of the extraction. The desorption was carried out with a home‐made desorption chamber allowing thermostating. Only 1 min sorption and 1 min desorption were performed, after which MS detection took place, resulting in a total analysis time of 3 min. Detection limits below 1 ng/mL could be obtained despite yields of only 2.1 and 1.5% for a 100‐ and a 30‐μm PDMS‐coated fiber, respectively. Furthermore, the determination of lidocaine in urine had acceptable reproducibilities, i.e., relative standard deviations (RSDs) below 10%. A limit of quantitation (RSD < 15%) of about 1 ng/mL was obtained. No extra wash step of the extraction fiber was required after desorption if a 30‐μm coating was used, whereas not all the analyte was desorbed from the 100‐μm coating in a single desorption. Therefore, the SPME‐MS/MS system with a 30‐μm PDMS‐coated fiber for rapid non‐equilibrium SPME at elevated temperatures has interesting potential for high‐throughput analysis of biological samples.  相似文献   

8.
Solid-phase microextraction (SPME) coupled with gas chromatography-mass spectrometry (GC-MS) was used to determine pesticide residues in Chinese herbal formulations. Fibers coated with a 100-microm film thickness of poly(dimethylsiloxane) was used to extract 19 organochlorine pesticides (OCPs). The pesticides in the study consisted of alpha-, beta-, gamma-and delta-hexachlorocyclohexane, p,p'-DDD, p,p'-DDE, p,p'-DDT, o,p'-DDT, aldrin, dieldrin, endrin, endrin aldehyde, endrin ketone, endosulfan (I, II and sulfate), heptachlor, heptachlor epoxide, and methoxychlor. The optimal experimental procedures for the adsorption and desorption of pesticides were evaluated. The linearity was obtained with a precision below 11% RSD for the studied pesticides expect endosulfan sulfate (21%) in a wide range from 1 to 200 ng/g. Detection limits were reached at below ng/g levels. Heptachlor epoxide was determined at a calculated limit of 0.03 ng/g. Comparison between SPME and Soxhlet extraction showed that SPME has a less than one order detection limit for residue pesticide determination. The proposed method was tested by analyzing herbal formulations from a local market for OCP multiresidues. Some residues studied were detected in the analyzed samples. The results demonstrate the suitability of the SPME-GC-MS approach for the analysis of multi-residue OCPs in Chinese herbal formulations.  相似文献   

9.
Solid-phase microextraction (SPME) coupled to LC for the analysis of five diphenylether herbicides (aclonifen, bifenox, fluoroglycofen-ethyl, oxyfluorfen, and lactofen) is described. Various parameters of extraction of analytes onto the fiber (such as type of fiber, extraction time and temperature, pH, impact of salt and organic solute) and desorption from the fiber in the desorption chamber prior to separation (such as type and composition of desorption solvent, desorption mode, soaking time, and flush-out time) were studied and optimized. Four commercially available SPME fibers were studied. PDMS/divinylbenzene (PDMS/DVB, 60 microm) and carbowax/ templated resin (CW/TPR, 50 microm) fibers were selected due to better extraction efficiencies. Repeatability (RSD, < 7%), correlation coefficient (> 0.994), and detection limit (0.33-1.74 and 0.22-1.94 ng/mL, respectively, for PDMS/DVB and CW/TPR) were investigated. Relative recovery (81-104% for PDMS/DVB and 83-100% for CW/TPR fiber) values have also been calculated. The developed method was successfully applied to the analysis of river water and water collected from a vegetable garden.  相似文献   

10.
A solid-phase microextraction (SPME) procedure has been developed for the determination of 16 US Environmental Protection Agency promulgated polycyclic aromatic hydrocarbons (PAHs). Five kinds of SPME fibers were used and compared in this study. The extracted sample was analyzed by gas chromatography with flame ionization detection or mass spectrometry. Parameters affecting the sorption of analyte into the fibers, including sampling time, thickness of the fiber coating, and the effect of temperature, have been examined. Moreover, the feasibility of headspace SPME with different working temperatures was evaluated. The method was also applied to real samples. The 85-microm polyacrylate (PA) and 100-microm poly(dimethylsiloxane) (PDMS) fibers were shown to have the highest affinities for the selected PAHs. The PA fiber was more suitable than the PDMS fiber for the determination of low-ring PAHs while high sensitivity of high-ring PAHs was observed when a 100-microm PDMS fiber was used. The method showed good linearity between 0.1 and 100 ng/ml with regression coefficients ranging from 0.94 to 0.999. The reproducibility of the measurements between fibers was found to be very good. The precisions of PA and PDMS fibers were from 3 to 24% and from 3 to 14%, respectively. Headspace SPME is a valid alternative for the determination of two- to five-ring PAHs. A working temperature of 60 degrees C provides significant enhancement in sensitivity of two- to five-ring PAHs having low vapor pressures (>10(-6) mmHg at 25 degrees C) (1 mmHg = 133.3 Pa) and low Henry's constants (>10 atm ml/mol) (1 atm = 1.01 x 10(5) Pa).  相似文献   

11.
The use of two methods in tandem, single-sided membrane introduction mass spectrometry (SS-MIMS) and fiber introduction mass spectrometry (FIMS), is presented as a technique for field analysis. The combined SS-MIMS-FIMS technique was employed in both a modified commercial mass spectrometer and a miniature mass spectrometer for the selective preconcentration of the explosive simulant o-nitrotoluene (ONT) and the chemical warfare agent simulant, methyl salicylate (MeS), in air. A home-built FIMS inlet was fabricated to allow introduction of the solid-phase microextraction (SPME) fiber into the mass spectrometer chamber and subsequent desorption of the trapped compounds using resistive heating. The SS-MIMS preconcentration system was also home-built from commercial vacuum parts. Optimization experiments were done separately for each preconcentration system to achieve the best extraction conditions prior to use of the two techniques in combination. Improved limits of detection, in the low ppb range, were observed for the combination compared to FIMS alone, using several SS-MIMS preconcentration cycles. The SS-MIMS-FIMS response for both instruments was found to be linear over the range 50 to 800 ppb. Other parameters studied were absorption time profiles, effects of sample flow rate, desorption temperature, fiber background, memory effects, and membrane fatigue. This simple, sensitive, accurate, robust, selective, and rapid sample preconcentration and introduction technique shows promise for field analysis of low vapor pressure compounds, where analyte concentrations will be extremely low and the compounds are difficult to extract from a matrix like air.  相似文献   

12.
A new analysis method to detect carbamates and phenylurea pesticide residues in fruit juices was developed using solid-phase microextraction (SPME) coupled with liquid chromatography-single quadrupole mass spectrometry (LC/MS) and liquid chromatography-quadrupole ion trap mass spectrometry (LC/QIT-MS). The pesticide residues present in watery matrices as fruit juices were extracted using three types of fibers: 50-microm Carbowax/templated resin (CW/TPR), 60-mum poly(dimethylsiloxane)/divinylbenzene (PDMS/DVB) and 85-microm polyacrylate. The different extraction conditions were evaluated choosing as the best parameters 90 min (time), 20 degrees C (temperature) and 1 ml (volume). After extraction, the desorption (in a static mode) was performed in the specific interface chamber SPME/HPLC, previously filled with 70% methanol and 30% water. The best recoveries, evaluated at two fortification levels (0.2 and 0.5 mg kg(-1)) in fruit juices, were obtained using PDMS/DVB and CW/TPR fibers, and ranged from 25 to 82% (monolinuron, diuron and diethofencarb), with relative standard deviations (RSDs) from 1 to 17%. All the limits of quantification (LOQs) were in the range of 0.005-0.05 microg ml(-1) and, in any case, equal to, or lower than, maximum residue limits (MRLs) established by Italian and Spanish legislations. The mass spectrometry analyses were carried out using an electrospray ionization (ESI) source operating in the positive mode both for single quadrupole and for QIT mass analysers, operating in selected ion monitoring (SIM) and in multiple reaction monitoring (MRM) modes, respectively. The proposed new method can be applied to the determination of selected pesticides in real samples of fruit juices.  相似文献   

13.
陈娜  张毅军  赵万里  陈军  张裕平 《色谱》2018,36(1):5-11
采用氯化胆碱-乙二醇低共熔溶剂(DES)作致孔剂,制备了聚(甲基丙烯酸丁酯-乙二醇二甲基丙烯酸酯)[poly(BMA-EDMA)]固相微萃取头,并与超高效液相色谱法(UPLC)结合测定了湖水中的3种多环芳烃(PAHs)。实验与不使用DES致孔剂的固相微萃取头和商品化聚二甲硅氧烷(PDMS)萃取头进行比较,含DES的poly(BMA-EDMA)固相微萃取头的富集效果最好。系统考察了萃取条件(萃取时间、萃取溶剂、解吸时间、解吸溶剂及离子强度)对水样中多环芳烃萃取效率的影响。在最优的实验条件下,3种多环芳烃类化合物(萘、联苯、菲)的线性范围为0.1~6.0 mg/L(r≥0.990 3),检出限为2.1~4.9μg/L,回收率为86.4%~111.3%,相对标准偏差(RSD,n=6)为11.2%~15.1%。该法操作简便,稳定性好,成本低,适用于实际环境水样中多环芳烃类化合物的测定。  相似文献   

14.
The use of solid-phase microextraction (SPME) coupled to ion mobility spectrometry (IMS) to detect precursor and degradation products of chemical warfare agents (CWAs) as soil contaminants was investigated. The development and characterization of a system to interface a thermal desorption solid-phase microextraction inlet with a hand held ion mobility spectrometer was demonstrated. The analytes used in this study were diisopropyl methylphosphonate (DIMP), diethyl methylphosphonate (DEMP), and dimethyl methylphosphonate (DMMP). Two SPME fibers with different stationary phases, 100 μm polydimethylsiloxane (PDMS) and 65 μm polydimethylsiloxane divinylbenzene (PDMS/DVB), were evaluated in this study to determine the optimal fiber and extraction conditions. Better results were obtained with the PDMS fiber. SPME-IMS offered good repeatability and detection of the precursor and degradation products in spiked soil at concentrations as low as 10 μg/g. Sample analysis time was less than 30 min for all the precursor and degradation products.  相似文献   

15.
A sol-gel method for the preparation of solid-phase microextraction (SPME) fiber was described and evaluated. The extraction phase of poly(dimethysiloxane) (PDMS) containing 3% vinyl group was physically incorporated into the sol-gel network without chemical bonding. The extraction phase itself is then partly crosslinked at 320 degrees C, forming an independent polymer network and can withstand desorption temperature of 290 degrees C. The headspace extraction of BTX by the fiber SPME was evaluated and the detection limit of o-xylene was down to 0.26 ng/l. Extraction and determination of organophosphorus pesticides (OPPs) in water, orange juice and red wine by the SPME-GC thermionic specified detector (TSD) was validated. Limits of detection of the method for OPPs were below 10 ng/l except methidathion. Relative standard deviations (RSDs) were in the range of 1-20% for pesticides being tested.  相似文献   

16.
The solid-phase microextraction (SPME) technique with on-fiber derivatization was evaluated for the analysis of aldehydes in water. The poly(dimethylsiloxane)/divinylbenzene (PDMS/DVB) fiber was used and O-2,3,4,5,6-(pentafluorobenzyl)hydroxylamine hydrochloride (PFBHA) were first loaded onto the fiber. The aldehydes in water sample were agitated into headspace and extracted by SPME with on-fiber derivatization. Gas chromatography/mass spectrometry (GC/MS) was used for the analysis of oximes formed and the adsorption-time profiles were examined. The precision, recovery and method detection limits (MDLs) were evaluated with spiked bidistilled water, chlorinated tap water as well as well water. The relative standard deviations from different spiked water sample were all less than 10% and the recoveries were 100 +/- 15%. With 2 ml of water sample, MDLs were in the range of 0.12-0.34 microg/l. Compared with other techniques, the study shown here provided a simple, fast and reliable method for the analysis of aldehydes in water.  相似文献   

17.
A new generation of solid-phase microextraction (SPME) fiber, an internally cooled fiber (cold fiber with polydimethylsiloxane loading) that allows heating the sample matrix and simultaneously cooling the fiber coating, was used to determine 2,4-dichloroanisole, 2,6-dichloroanisole, 2,4,6-trichloroanisole and pentachloroanisole in cork. A comparison between the cold fiber and regular SPME fiber was performed. An automated headspace solid-phase microextraction (HS-SPME) using commercial fibers and an internally cooled SPME fiber (CF-HS-SPME) coupled to gas chromatography-time-of-flight mass spectrometry (GC-TOF-MS) was used. The extraction conditions for both CF-HS-SPME and HS-SPME were optimized using full factorial design and Doehlert matrix. The best extraction conditions for CF-HS-SPME were obtained using 10 min of incubation time, 10 min of extraction time, and sample and fiber temperature of 130 and 10 degrees C, respectively. For HS-SPME, polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber was used with 10 min of incubation time, 75 min of extraction time, 85 degrees C of sample temperature, 8 ml of water was added and agitated at 500 rpm. The quantification limits for the target compounds using CF-HS-SPME procedure were between 0.8 and 1.6 ng g(-1) of cork, while for HS-SPME were between 4 and 6 ng g(-1) of cork. Furthermore, the CF-HS-SPME procedure could be used as a non-destructive method after minor modification of the agitator for the autosampler.  相似文献   

18.
A simple, sensitive and rapid method for the determination of diisopropylfluorophosphate (DFP) in rat plasma and brain tissue using headspace solid-phase microextraction (HS-SPME) and gas chromatography/mass spectrometry (GC/MS) is presented. A 65 microm polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber was selected for sampling. The main parameters affecting the SPME process such as extraction and desorption temperature, extraction and desorption time, salt addition, and fiber preheating time were optimized in each matrix to enhance the extraction efficiency of the method. The lower limits of quantitation for DFP in plasma and brain tissue were 1 ng/mL and 3 ng/g, respectively. The method showed good linearity over the range from 1-100 ng/mL in plasma and 3-300 ng/g in brain tissue with correlation coefficient (R(2)) values higher than 0.995. The precision and accuracy for intra-day and inter-day were less than 10%. The relative recoveries in plasma and brain for DFP were greater than 50%. Stability tests including autosampler and freeze and thaw were also investigated. This validated method was successfully applied to study the neurobehavioral effects of low-level organophosphate exposures. Copyright (c) 2008 John Wiley & Sons, Ltd.  相似文献   

19.
The aroma profile of cocoa products was investigated by headspace solid-phase micro-extraction (HS-SPME) combined with gas chromatography–mass spectrometry (GC–MS). SPME fibers coated with 100 μm polydimethylsiloxane coating (PDMS), 65 μm polydimethylsiloxane/divinylbenzene coating (PDMS-DVB), 75 μm carboxen/polydimethylsiloxane coating (CAR-PDMS) and 50/30 μm divinylbenzene/carboxen on polydimethylsiloxane on a StableFlex fiber (DVB/CAR-PDMS) were evaluated. Several extraction times and temperature conditions were also tested to achieve optimum recovery. Suspensions of the samples in distilled water or in brine (25% NaCl in distilled water) were investigated to examine their effect on the composition of the headspace. The SPME fiber coated with 50/30 μm DVB/CAR-PDMS afforded the highest extraction efficiency, particularly when the samples were extracted at 60 °C for 15 min under dry conditions with toluene as an internal standard. Forty-five compounds were extracted and tentatively identified, most of which have previously been reported as odor-active compounds. The method developed allows sensitive and representative analysis of cocoa products with high reproducibility. Further research is ongoing to study chocolate making processes using this method for the quantitative analysis of volatile compounds contributing to the flavor/odor profile.  相似文献   

20.
Headspace solid phase microextraction (HS-SPME) in-situ supercritical fluid extraction (SFE) was investigated for the determination of trace amounts of perfluorocarboxylic acids (PFCAs) in sediments. Quantitation was performed by using gas chromatography coupled to negative chemical ionization-tandem mass spectrometry (GC-NCI-MS/MS). The optimum conditions of HS-SPME following SFE were obtained using 500 μL n-butanol as a derivatization reagent in supercritical carbon dioxide with static extraction for 10 min, then dynamic extraction for 20 min at 30 MPa and 70 °C and simultaneous collected with 100 μm film thickness PDMS fiber. The linear range of proposed method was from 5 to 5000 ng g(-1), with limit of detection ranging from 0.39 to 0.54 ng g(-1) and limit of quantitation ranging from 1.30 to 1.80 ng g(-1). The developed method was successfully applied to analyze PFCAs in sediments from rivers and beach near industrial areas. The concentrations of PFCAs determined are from 282 to 4473 ng g(-1).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号