首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this paper electropolymerization of a thin film of para‐phenylenediamine (PPD) is studied at glassy carbon electrode (GCE) in sulfuric acid media by cyclic voltammetry. The results showed that this polymer was conducting and had a reproducible redox couple in the potential region from 0.0 to 0.4 V in phosphate buffer solution. This modified GCE (p‐PPD‐GCE) was applied for simultaneous determination of ascorbic acid (AA), dopamine (DA) and uric acid (UA) using differential pulse voltammetry (DPV). The p‐PPD‐GCE in 0.1 M phosphate buffer solution (pH 5.0) separated the DPV signals of AA, DA and UA with sufficient potential differences between AA–DA and DA–UA and also enhanced their oxidation peak currents. The oxidation currents were increased from 2.0 to 2000.0 µM for AA, 10.0 to 1250.0 µM for DA and 50.0 to 1600.0 µM for UA. The detection limits were evaluated as 0.4, 1.0 and 2.5 µM for AA, DA and UA, respectively (S/N=3).  相似文献   

2.
An electropolymerized film of eriochrome black T (EBT) has been prepared at a glassy carbon electrode (GCE) by cyclic voltammetry (CV). The poly(EBT) membrane at GCE exhibits an excellent electrocatalytic activity towards the oxidation of epinephrine (EP), ascorbic acid (AA) and uric acid (UA) in acidic solution and reduced the overpotential for the oxidation of EP. The poly(EBT)-coated electrode could separately detect EP, AA and UA in their mixture with the potential differences of 180 and 160 mV for EP-AA and UA-EP, respectively, which are large enough to allow for determination of EP in the presence of AA and UA. Using differential pulse voltammetry, the peak current of EP recorded in pH 3.5 solution was linearly dependent on EP's concentration in the range of 2.5 - 50 microM. Due to its good selectivity and stability, the polymer-coated GCE was successfully applied to the determination of EP in real samples.  相似文献   

3.
Electrochemically polymerized luminol film on a glassy carbon electrode (GCE) surface has been used as a sensor for selective detection of uric acid (UA) in the presence of ascorbic acid (AA) and dopamine (DA). Cyclic voltammetry was used to evaluate the electrochemical properties of the poly(luminol) film modified electrode. Scanning electron microscopy (SEM) and atomic force microscopy (AFM) have been used for surface characterizations. The bare GCE failed to distinguish the oxidation peaks of AA, DA and UA in phosphate buffer solution (pH 7.0), while the poly(luminol) modified electrode could separate them efficiently. In differential pulse voltammetric (DPV) measurements, the modified GCE could separate AA and DA signals from UA, allowing the selective determination of UA. Using DPV, the linear range (3.0×10?5 to 1.0×10?3 M) and the detection limit (2.0×10?6 M) were estimated for measurement of UA in physiological condition. The applicability of the prepared electrode was demonstrated by measuring UA in human urine samples.  相似文献   

4.
A multiwalled carbon nanotubes (MWNT) modified glassy carbon electrode (GCE) coated with poly(orthanilic acid) (PABS) film (PABS–MWNT/GCE) has been fabricated and used for simultaneous determination of dopamine (DA) and uric acid (UA) in the presence of ascorbic acid (AA) by differential pulse voltammetry (DPV). Scanning electron microscopy, Fourier transform infrared spectra, and electrochemical techniques have been used to characterize the surface morphology of the PABS–MWNT composite film and the polymerization of ABS on electrode surface. In comparison with the bare GCE and the MWNT-modified GCE, the PABS–MWNT composite film-modified GCE, which combines the advantages of MWNT and the self-doped PABS, exhibits good selectivity and sensitivity for the simultaneous and selective determination of UA and DA in the presence of AA. Due to the different electrochemical responses of AA, DA, and UA, PABS–MWNT/GCE can resolve the overlapped oxidation peak of DA and UA into two well-defined voltammetric peaks with enhanced current responses using both cyclic voltammetry (CV) and DPV. The peak potential separations between DA and UA are 170 mV using CV and 160 mV using DPV, respectively, which are large enough for the selective and simultaneous determination of these species. In the presence of 0.5 mM AA, the DPV peak currents are linearly dependent on the concentration of UA and DA in the range of 6–55 and 9–48 μM with correlation coefficients of 0.997 and 0.993, respectively. The detection limits (S/N = 3) for detecting UA and DA are 0.44 and 0.21 μM, respectively. The PABS–MWNT/GCE shows good reproducibility and stability and has been used for the simultaneous determination of DA and UA in the presence of AA in samples with satisfactory results.  相似文献   

5.
This paper describes the simultaneous determination of ascorbic acid (AA), norepinephrine (NE) and uric acid (UA) using a graphene modified glassy carbon electrode (GME) in pH 4.0 phosphate buffer solution. The electrochemical behaviors of AA, NE and UA at a bare glassy carbon electrode (GCE) and the GME were studied by cyclic voltammetry. Bare GCE failed to resolve the voltammetric signals of AA, NE and UA in a mixture, whereas the GME not only resolved their voltammetric signals, but also exhibited excellent electrocatalytic activity towards their electrochemical oxidation. The oxidation peak currents of AA, NE and UA were linearly proportional to their concentrations over the range of 1.0.0–1000.0, 0.6–45.0 and 1.0–100.0 μM, respectively, and their detection limits were 1.2, 0.10 and 0.60 μM, respectively, The modified electrode is of excellent sensitivity and selectivity, and has been satisfactorily used for the simultaneous determination of AA, NE and UA in their ternary mixture.  相似文献   

6.
制备了甘氨酸-壳聚糖复合膜修饰玻碳电极(Gly-CTS/GCE),研究了抗坏血酸(AA)和尿酸(UA)在该修饰电极上的电化学行为。结果表明在pH=5.59的磷酸盐缓冲溶液中,AA、UA在Gly-CTS/GCE上均产生灵敏的不可逆氧化峰,其峰电流与浓度在一定范围内呈良好的线性关系。对AA和UA混合溶液平行测定7次,相对标准偏差分别为4.6%、2.9%,表明该电极重现性和稳定性良好。AA、UA在Gly-CTS/GCE电极上的氧化峰峰电位相差340mV,据此可实现对二者的同时检测,并可应用于实际样品测定。  相似文献   

7.
An electrochemical sensor for simultaneous determination of dopamine (DA), uric acid (UA), guanine (G), and adenine (A) has been constructed by copolymerizing melamine monomer and Ag ions on a glassy carbon electrode (GCE) with cyclic voltammetry. The poly-melamine and nano Ag formed a hybridized film on the surface of the GCE. The morphology of the film was characterized by scanning electron microscope. The electrochemical and electrocatalytic properties of this film were characterized by cyclic voltammetry, linear sweep voltammetry, and square wave voltammetry (SWV). In 0.1 M phosphate buffer solution (pH 4.5), the modified electrode resolved the electrochemical response of DA, UA, G, and A into four well-defined voltammetric oxidation peaks by SWV; the oxidation peak current of DA, UA, G, and A increased 13-, 6-, 7-, and 9-fold, respectively, compared with those at the bare GCE and the SWV peak currents of DA, UA, G, and A with linear concentrations in the ranges of 0.1–50, 0.1–50, 0.1–50, and 0.1–60 μM, respectively. Based on this, a method for simultaneous determination of these species in mixture was setup. The detection limits were 10 nM for DA, 100 nM for UA, 8 nM for G, and 8 nM for A.  相似文献   

8.
Zhang Y  Su S  Pan Y  Zhang L  Cai Y 《Annali di chimica》2007,97(8):665-674
Trans-3-(3-pyridyl) acrylic acid (PAA) was deposited on glassy carbon electrode (GCE) by electropolymerization in pH 7.0 phosphate buffer solution (PBS). The poly (3-(3-pyridyl) acrylic acid) (PPAA) film modified glassy carbon electrode shows an excellent electrochemical response for dopamine (DA), ascorbic acid (AA) and uric acid (UA). The cyclic voltammetry oxidation peaks for DA and AA, DA and UA, AA and UA are separated by 150 mV, 130 mV and 280 mV, respectively. This permits the simultaneous determination of AA, DA and UA. The interference of AA with the determination of DA could be eliminated because of the electrostatic interaction between DA cations and the negatively charged PPAA film at pH 7.0. The anodic peak currents of DA, AA and UA increase linearly with concentration in the range of 1-40 micromol L(-1), 10-400 micromol L(-1) and 1.6-80 micromol L(-1), respectively, with a correlation coefficient (r) always higher than 0.998. The detection limit is 0.06 micromol L(-1), 0.8 micromol L(-1) and 1.1 micromol L(-1) for DA, AA and UA, respectively.  相似文献   

9.
《Analytical letters》2012,45(1):22-33
A three-dimensional L-cysteine (L-cys) monolayer assembled on gold nanoparticles (GNP) providing simultaneous detection of uric acid (UA) and ascorbic acid (AA) was studied in this work. The cyclic voltammetry demonstrated that, at a bare glassy carbon electrode (GCE) or planar gold electrode, the mixture of UA and AA showed one overlapped oxidation peak; whereas when the electrode was modified with GNP, the oxidation peaks for UA and AA were separated. While a GNP modified electrode was further modified with L-cys monolayer (L-cys/GNP/GCE), namely, three-dimensional L-cys monolayer, a better separation for UA and AA response was obtained. Interestingly, the L-cys monolayer-modified planar gold electrode presented a block effect on the oxidation of AA, which was facilitated by the three-dimensional L-cys monolayer attributed to its distinct structure. The pH of solution presented a noticeable effect on the separation of UA and AA at GNP modified electrodes with or without L-cys monolayer. Wide concentration ranges from 2 × 10?6?1 × 10?3 M to UA and 2 × 10?6?8 × 10?4 M to AA could be obtained at L-cys/GNP/GCE.  相似文献   

10.
朱小红  林祥钦 《中国化学》2009,27(6):1103-1109
用循环伏安法(CV)选择不同电位区间来电聚合烟酰胺(NA)得到了两种聚合物膜修饰电极:poly-niacinamide/GCE (poly-NA/GCE)和poly- nicotinic acid /GCE (poly-NC/GCE)。这两电极都具有显著电化学催化作用,能明显地降低多巴胺(DA)、尿酸(UA)和抗坏血酸(AA)的氧化过电位,并在混合溶液中使这些物质的氧化峰电位距离足够大,可进行三物质的同时测定。poly-NC/GCE的电催化性能更好一些,用差分脉冲伏安法(DPV)测定抗坏血酸,线性范围为75–3000 µmol L-1,电流灵敏度为5.6 mA•L•mol-1;测定多巴胺,线性范围为0.37 – 16 µmol L-1,电流灵敏度为1140 mA•L•mol-1; 测定尿酸,线性范围为0.74 – 230 µmol L-1,电流灵敏度为102 mA•L•mol-1。该电极具有很高的灵敏度、选择性和抗污染能力。  相似文献   

11.
In this work, a new nanomaterial of thiol functional ferrocene derivative (Fc-SH) stabilized Au NPs/carbon dots nanocomposite (Au/C NC) coupling with graphene modified glassy carbon electrode (Fc-S-Au/C NC/graphene/GCE) was fabricated to serve as a quadruplet detection platform for ultrasensitive and simultaneous determination of ascorbic acid (AA), dopamine (DA), uric acid (UA) and acetaminophen (AC). The Au/C NC was synthesized by adding HAuCl4 into carbon nanodots solution without using any additional reductant and stabilizing agent. Then the Fc-SH was utilized as the protective and capping agent to modify the Au/C NC. Transmission electron microscopy (TEM), UV–Vis, Fourier-transform infrared (FT-IR), scanning electron microscopy (SEM), cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) were adopted to characterize the morphology and electrochemical properties of the materials and the electrodes. The Fc-S-Au/C NC/graphene/GCE exhibits a synergistic catalytic and amplification effects towards oxidation of AA, DA, UA and AC owing to the existence of the nanomaterial and electron mediator. When simultaneous detection of AA, DA, UA and AC, the oxidation peak potentials of the four compounds on the electrode can be well separated and the peak currents were linearly dependent on their concentrations. The quadruplet detection platform shows excellent linear range and ultrasensitive response to the four components, the detection limits were estimated to be as low as 1.00, 0.05, 0.12 and 0.10 μM (S/N = 3), and the modified electrode exhibits excellent stability and reproducibility. The proposed electrode has been successfully applied to detect of these four analytes in real samples with satisfactory results.  相似文献   

12.
《Electroanalysis》2006,18(24):2458-2466
A promising electrochemical biosensor was fabricated by electrochemical grafting of ribonucleic acid (RNA) at 1.8 V (vs. SCE) on glassy carbon electrode (GCE) (denoted as RNA/GCE), for simultaneous detection of dopamine (DA) and uric acid (UA) with coexistence of excess amount of ascorbic acid (AA). The electrode was characterized by X‐ray photoelectron spectroscopy (XPS), cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques. The RNA modified layer on GCE exhibited superior catalytic ability and anionic exclusive ability in comparison with the DNA modified electrode. Three separated anodic DPV peaks were obtained at 0.312, 0.168 and ?0.016 V for UA, DA and AA, respectively, at the RNA/GCE in pH 7.0 PBS. In the presence of 2.0 mM AA, a linear range of 0.37 to 36 μM with a detection limit of 0.2 μM for DA, and in the range of 0.74 to 73 μM with a detection limit of 0.36 μM for UA were obtained. The co‐existence of 5000 fold AA did not interfere with the detection of DA or UA. The modified electrode shows excellent selectivity, good sensitivity and good stability.  相似文献   

13.
采用电化学方法将钙羧酸(CCA)聚合修饰在玻碳电极(GCE)表面制备了聚钙羧酸指示剂修饰玻碳电极(PCCA/GCE),并用循环伏安法和交流阻抗法研究了电极的电化学性能。结果表明:在pH 6.0的磷酸盐缓冲溶液中,多巴胺(DA)和尿酸(UA)在聚钙羧酸修饰电极上的氧化峰得以分开,峰电位差为0.14V,据此提出了聚钙羧酸修饰电极差分脉冲伏安法同时测定多巴胺和尿酸的方法。DA和UA的浓度分别在5.0~43.8μmol.L-1和5.0~50.0μmol.L-1范围内与其氧化峰电流呈线性关系,检出限(3S/N)分别为0.2μmol.L-1和0.5μmol.L-1。方法可用于多巴胺注射液样品中DA和UA的测定,测定值的相对标准偏差(n=5)依次为2.43%和2.35%。  相似文献   

14.
The properties of graphite electrode (Gr) modified with poly(diallyl dimethyl ammonium chloride) (PDDA) for the detection of uric acid (UA) in the presence of dopamine (DA) and high concentration of ascorbic acid (AA) have been investigated by cyclic voltammetry, differential pulse voltammetry and chronoamperometry. The polymer modified graphite electrode was prepared by a very simple method just by immersing the graphite electrode in PDDA solution for 20 minutes. The PDDA/Gr modified electrode displayed excellent electrocatalytic activity towards the oxidation of UA, DA and AA compared to that at the bare graphite electrode. The electrochemical oxidation signals of UA, DA and AA are well resolved into three distinct peaks with peak potential separations of 220 mV, 168 mV and 387 mV between AA‐DA, DA‐UA and AA‐UA respectively in cyclic voltammetry studies and the corresponding peak potential separations are 230 mV, 130 mV and 354 mV respectively in differential pulse voltammetry. The lowest detection limits obtained for UA, DA and AA were 1×10?7 M, 2×10?7 M and 800×10?9 M respectively. The PDDA/Gr electrode efficiently eliminated the interference of DA and a high concentration of AA in the determination of UA with good selectivity, sensitivity and reproducibility. The modified electrode was also successfully applied for simultaneous determination of UA, DA and AA in their ternary mixture.  相似文献   

15.
历洋  李锦州  庞筱喆 《应用化学》2013,30(5):578-583
制备了一种新型电化学传感器--聚2,2-联吡啶(Pbpy)/1-苯基-3-甲基-4-(α-呋喃甲酰基)-5-吡唑啉酮(HPM-α-FP)/玻碳(GC)复合膜修饰电极。 运用循环伏安法和脉冲伏安法研究了药物分子黄嘌呤(XN)的电化学行为及反应机理。 与裸GCE和Pbpy/GCE电极相比,复合修饰电极Pbpy/HPM-α-FP/GCE测定XN的氧化峰电流和检测灵敏度均有显著提高,表明聚2,2-联吡啶与酰基吡唑啉酮产生了协同增效作用。 当pH=8,扫速为100 mV/s的条件下,氧化峰电流与黄嘌呤浓度在6×10-7~1×10-5 mol/L和1×10-5~1×10-4 mol/L之间均呈现良好的线性关系,检出限为1×10-8 mol/L。 该修饰电极可用于共存尿酸(UA)、抗坏血酸(AA)体系及实际样品的黄嘌呤含量测定。  相似文献   

16.
磷钨酸改性蒙脱土修饰电极对多巴胺与尿酸的测定   总被引:1,自引:1,他引:0  
制作了磷钨酸改性蒙脱土修饰电极(PTA-MMT/GCE),研究了该电极对多巴胺(DA)和尿酸(UA)的电化学响应特性.结果表明:在pH 6.5的PBS缓冲溶液中,DA在该电极上出现1对氧化还原峰,是受扩散控制的可逆电化学过程;UA在该修饰电极上0.328 V处出现一明显的氧化峰,电极过程为受扩散控制完全不可逆的过程.计算了DA和UA在该修饰电极上的反应电子数n和扩散系数.通过对比改性前后修饰电极的交流阻抗图,研究了电极表面的特性.用循环伏安法讨论了缓冲溶液、pH值、修饰剂用量、扫描速率及温度对测定的影响.在pH 6.5的PBS溶液中,DA和UA的氧化峰得到了较好地分离,且DA、UA的峰电流强度与浓度分别在2.0~110.0和20.0 ~350.0 μmol·L-1范围内呈良好的线性关系.运用该电极对盐酸多巴胺注射液以及人尿进行检测,效果良好,样品回收率分别为94%~102%、93% ~97%.  相似文献   

17.
《中国化学会会志》2017,64(11):1360-1366
Nitrogen‐doped graphene (NG) was used to modify a glassy carbon electrode (GCE), which was applied to the voltammetric detection of uric acid (UA). Because of the presence of NG on the GCE surface, the modified electrode showed excellent electrocatalytic ability for UA oxidation with increase of the peak current and decrease of the peak potential. Compared to that of the traditional GCE, the overpotential of the oxidation peak decreased by 50 mV. Electrochemical performance of UA was studied on NG/GCE in detail, which showed a quasi‐reversible, diffusional‐controlled process. Electrochemical parameters including the charge transfer coefficient (α ), the number of electron transfer (n ), and the diffusional coefficient (D ) were calculated. At the optimal conditions, the oxidation peak current was linear, with UA concentration from 0.1 to 10.0 μmol/L as revealed by differential pulse voltammetry, and the detection limit was estimated as 0.042 μmol/L (3σ). The UA content in the urine sample of a healthy volunteer was determined by the proposed method with a recovery of 98.7–102.3%.  相似文献   

18.
A glassy carbon electrode (GCE) modified with docosyltrimethylammonium chloride (DCTMACl) is used for simultaneous determination of dopamine (DA) and ascorbic acid (AA) using differential pulse voltammetry (DPV) technique in 0.10 mol·L?1 phosphate buffer solution of pH 5.0. The cationic surfactant DCTMACl modified film has a positive charge. DA exists as the positively charged species, whereas AA is the negatively charged one in the solution. Thus, at DCTMACl film-modified GCE, the oxidation peak potential of AA shifts toward less negative potential and the peak current of AA increases a little, while the oxidation peak potential of DA shifts toward more positive potential and peak current decreases greatly in comparison with that on bare electrode. The two anodic peaks are separated around 200 mV. Under optimal conditions, the catalytic peak currents obtained from DPV increase linearly with concentrations of DA and AA in the ranges of 1.0?×?10?5 to 1.0?×?10?3?mol·L?1. This electrode has good reproducibility, high stability in its voltammetric response, and low detection limit (micromolar) for both AA and DA. The modified electrode has been applied to the determination of DA and AA in injection.  相似文献   

19.
基于尿嘧啶作为一种碱基,具备一定的分子识别能力,制备了一种新颖的尿嘧啶共价修饰电极,用X射线光电子能谱和电化学方法进行了表征,并研究了酪氨酸、色氨酸、儿茶酚胺(如多巴胺,肾上腺素,去甲肾上腺素)及相关的化合物尿酸、抗坏血酸在该电极上的电化学行为,获得相应的氧化电位、电流灵敏度、线性范围和检测限等信息。其中,色氨酸检测线性范围:1.8 - 120 mM,检测限(s/n=3):0.8 mM;酪氨酸检测线性范围:1.8 - 89mM,检测限(s/n=3):0.8 mM。实验表明,尿嘧啶修饰电极能催化氧化上述电活性物质,但催化能力不同,据此,我们讨论了尿嘧啶与上述物质的相互作用,详细探讨了催化机理,扩展了对基于分子识别的传感器的研究。  相似文献   

20.
多巴胺是人体内一种重要的神经传递物质 ,它参与许多生命过程[1] .因此 ,测定体内多巴胺的浓度十分重要 .多巴胺的电化学分析方法已有不少报道 [2 ,3 ] .然而 ,共存的抗坏血酸和尿酸的电化学性质与多巴胺相似 ,对多巴胺的测定会产生严重干扰 .因此建立一种选择性测定多巴胺的高灵敏度的分析方法就显得尤为重要 .碳纳米管是一种新型的纳米材料 [4 ] ,它的出现引起了广泛的研究兴趣 [5,6] .由于其性质稳定 ,不溶于水及一般的有机溶剂 ,因此限制了其在电分析方面的应用 .本文将多壁碳纳米管分散在 Nafion的无水乙醇中 ,得到了一种均匀的多壁碳…  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号