首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
Qureshi M  Zehra N  Nabi SA  Kumar V 《Talanta》1973,20(7):609-620
The antimonate, arsenate, tungstate, molybdate and selenite of titanium have been synthesized. Their composition and chemical and thermal stability have been determined. Effects of pH and temperature on ion-exchange capacity have been studied. Titanium antimonate was found to be the most stable. The utility of these ion-exchangers for analytical separations was examined by determining the distribution coefficients for 26 metal ions in some aqueous, non-aqueous and mixed solvent systems. Quantitative separations of HgCd, PbCu and PbZn have been achieved on titanium tungstate columns, and LaBa mixtures have been separated on a titanium arsenate column.  相似文献   

2.
Diffusive gradients in thin films (DGT) and tangential-flow ultrafiltration (TF-UF) were combined for fractionation of Al and Cu in river water containing high content of dissolved organic carbon. A procedure based on ultrafiltration data is proposed to determine diffusion coefficients of the analytes in water samples and model solutions containing both free metal (M) and complex (metal - humic substance). Aiming to evaluate the accuracy of the proposed approach, the DGT results were compared with those from a protocol for determination of labile Al and Cu based on solid phase extraction (SPE). Good agreement between data from DGT and SPE were attained for model solutions. For analysis of real organic-rich water samples, differences between DGT and SPE measurements were consistent with the time-scales of the techniques. The concentration of labile Al determined by DGT were lower than the total dissolved concentrations (determined by inductively coupled plasma mass spectrometry) and exceeded the ultrafiltered concentration, indicating that inorganic Al species (species small enough to pass through 1 kDa membrane) were minor species as compared with Al organic complexes. For both Al and Cu, there were species not measured by DGT as they are not sufficiently labile.  相似文献   

3.
A procedure has been developed for the determination of tungstate at trace levels in aqueous extracts of soil and sludge by single-column ion chromatography (SCIC). Chromatographic parameters based on ion selectivity, time of determination and signal response were optimized for tungstate with the simultaneous detection of nitrate and sulfate. Chloride, phosphate, chromate, molybdate and vanadate were found not to interfere in the determination. A low-capacity resin-based column was used for the separation with p-hydroxybenzoic acid (5 mM) at pH 8.5 as the eluent. The limit of detection defined as three times the signal-to-noise ratio was 170 μg l?1 (2-ml sample). The resolution between tungstate and sulfate was Rs=2.84. The results for aqueous extracts agree closely with those obtained by an accepted spectrophotometric method.  相似文献   

4.
This study investigated several knowledge gaps with respect to the diffusive gradients in thin films (DGT) technique for measurement of oxyanions (As(III), As(V), Se(IV), Se(VI), PO43−, and V(V)) using the ferrihydrite and Metsorb™ binding layers. Elution efficiencies for each binding layer were higher with 1:20 dilutions, as analytical interferences for ICP-MS were minimised. Diffusion coefficients measured by diffusion cell and by DGT time-series experiments were found to agree well and generally agreed with previously reported values, although a range of diffusion coefficients have been reported for inorganic As and Se species. The relative binding affinity for both ferrihydrite and Metsorb™ was PO43− ≈ As(V) > V(V) ≈ As(III) > Se(IV) ? Se(VI) and effective binding capacities were measured in single ion solutions, and spiked synthetic freshwater and seawater, advising practical decisions about DGT monitoring. Under the conditions tested the performance of both ferrihydrite and Metsorb™ binding layers was directly comparable for As(V), As(III) Se(IV), V(V) and PO43− over a deployment spanning ≤2 days for both freshwater and seawater. In order to return quantitative data for several analytes we recommend that the DGT method using either ferrihydrite or Metsorb™ be deployed for a maximum of 2 days in marine waters likely to contain high levels of the most strongly adsorbing oxyanions contaminants. The high pH, the competitive ions present in seawater and the identity of co-adsorbing ions affect the capacity of each binding layer for the analytes of interest. In freshwaters, longer deployment times can be considered but the concentration and identity of co-adsorbing ions may impact on quantitative uptake of Se(IV). This study found ferrihydrite-DGT outperformed Metsorb-DGT while previous studies have found the opposite, with variation in binding materials masses used being a likely reason. Clearly, preparation of both binding layers should always be optimised to produce the highest capacity possible, especially for seawater deployments.  相似文献   

5.
Two adsorbents (Metsorb and ferrihydrite) used in binding layers with the diffusive gradients in a thin film technique were evaluated for the measurement of dissolved reactive phosphorous (DRP) in synthetic and natural waters. Possible interferences were investigated with Cl(-) (up to 1.35 mol L(-1)) and SO(4)(2-) (up to 0.056 mol L(-1)) having no affect on either DGT binding layer, and HCO(3)(-) (up to 5.7 mmol L(-1)) having no effect on Metsorb-DGT, over 4 days. However, HCO(3)(-) interfered with the ferrihydrite-DGT measurement at concentrations typical of many natural waters (≥0.7 mmol L(-1)) after a deployment period of 1-2 days. The capacity of the Metsorb binding phase for DGT response was ~37,000 ng P, whereas the capacities of a low-mass (17.8 mg of adsorbent per DGT sampler) and high-mass (29.2mg of adsorbent per DGT sampler) ferrihydrite binding phase were substantially lower (~15,000 ng P and ~25,000 ng P, low-mass and high-mass, respectively). Increasing the capacity of the ferrihydrite adsorbent allowed the ferrihydrite-DGT to be utilized for up to 3 days before interference by HCO(3)(-) was observed. Seawater deployments demonstrated that even high-capacity ferrihydrite-DGT devices underestimated the DRP concentration by 37%, whereas Metsorb-DGT measurements were accurate. The Metsorb-DGT is superior to the ferrihydrite-DGT for determining DRP over deployment times greater than 1 day and in waters with ≥0.7 mmol L(-1) HCO(3)(-). Based on the experience obtained from this detailed validation process, the authors propose a number of key requirements that need to be considered when developing new DGT binding layers, with testing the performance over longer deployment times being critical.  相似文献   

6.
The new heteroditopic ligand 2,3-dihydroxy-N-(1,10-phenanthroline-5-yl)benzamide (H2-L3) was synthesized and coordinated to [Ru(bpy)2(phen)]2+- and [ReBr(CO)3(phen)]-type luminophores (bpy = 2,2'-bipyridine and phen = 1,10-phenanthroline). The resulting chemosensors [Ru(bpy)2(H2-L3)]2+ and [ReBr(CO)3(H2-L3)] were fully characterized and their solid-state structures and spectroscopic properties were investigated to assess how the photophysical properties of the luminescent signaling units affect the performance of the sensors. [Ru(bpy)2(H2-L3)]2+ and [ReBr(CO)3(H2-L3)] both signal the presence and concentration of molybdate and vanadate in aqueous acetonitrile through a decrease in emission intensity. [ReBr(CO)3(H2-L3)] also detects tungstate. Due to the higher emission intensity of the Ru-based sensor, its detection limits for molybdate (43 microg L(-1)) and vanadate (24 microg L(-1)) are almost 1 order of magnitude lower than the ones achieved with the Re-based sensor. The optimum working pH of the chemosensors is determined by the pKa values of the 2-hydroxy-groups of the receptor units: pH 4 for [ReBr(CO)3(H2-L3)] and pH 3 for [Ru(bpy)2(H2-L3)]2+. Both sensors are selective: equimolar amounts of PO4(3-), SO4(2-), ReO4-, Mn(II), Fe(III), Co(II), Ni(II), Cu(II), and Zn(II) do not interfere with the detection of molybdate or vanadate.  相似文献   

7.
In situ measurements of copper and zinc using diffusive gradients in thin films (DGT) in two distinct natural water systems were compared to metal speciation assessed by competitive ligand exchange (CLE) and voltammetric measurements. In a dynamic river system, where dissolved metal concentrations vary significantly over short-time periods, DGT technique provided averaged values of the metal concentrations over time. In microcosms, at different total dissolved concentrations of copper and zinc, DGT technique measured a similar fraction as measurements of labile metal performed by voltammetry. The proportion of DGT and voltammetric-labile zinc to dissolved zinc was 61±4% and, respectively, 76±9%. DGT technique was measuring 81±8% of exchangeable copper (by exchange with catechol). These two fractions were similarly influenced by the addition of NTA. In the absence of NTA, copper measured by DGT represented 34±4% of dissolved copper whereas in the presence of NTA, this proportion raised to 57±2%. These measurements were compared to calculations performed with speciation programs using several models for the complexation by humic and fulvic substances, namely Model VI (WHAM), NICA-Donnan and SHM. The predicted speciation by these three models was similar. The prediction of free zinc ion and labile zinc concentrations were in agreement with experimental data. Calculated concentrations of free copper ion were overestimated because these models are not considering strong specific copper-binding ligands probably present in natural water.  相似文献   

8.
The toxic properties of tungsten compounds have recently been brought to the forefront with clusters of human cancer cases, such as in Fallon, NV. Such instances have made the determination of tungsten in natural water supplies vitally important. Tungsten exists in most environmental matrices as the soluble and mobile tungstate anion, although it can polymerize with itself and other anions, such as molybdate and phosphate. Because the geochemical and toxicological properties of these polymer species will vary from the monomeric tungstate parent, determination of tungstate speciation is as critical as determination of total dissolved tungsten concentration. Use of chromatographic separations, followed by element-specific detection is a proven technology for elemental speciation. In the present work, anion exchange chromatography has been coupled to inductively coupled plasma mass spectrometry to determine tungstate, molybdate, and phosphate species at the sub-μg l−1 and μg l−1 levels. The method provides quantitative determination of these species in about 10 min with the capability to simultaneously determine other oxyanion species. The method has been applied to groundwater and extracts of soils amended with tungsten powder. The water soluble tungsten in 1-h deionized water extracts after six months of soil aging was >15 mg l−1, however, only 50% of the tungsten was present as monomeric tungstate.  相似文献   

9.
A sensitive and selective method is developed for the spectrophotometric determination of trace amounts of arsenic. The method is based on the reaction of arsenate with acidified molybdate and vanadate to form molybdovanadoarserate complex which then interacts with cationic dye, rhodamine B to form an ion-pair.  相似文献   

10.
The diffusive gradients in thin films (DGT) technique, utilizing an iron-hydroxide adsorbent, has been investigated for the in situ accumulation of total dissolved inorganic As in natural waters. Diffusion coefficients of the inorganic As(V) and As(III) species in the polyacrylamide gel were measured using a diffusion cell and DGT devices and a variety of factors that may affect the adsorption of the As species to the iron-hydroxide adsorbent, or the diffusion of the individual As species, were investigated. Under conditions commonly encountered in environmental samples, solution pH and the presence of anions, cations, fulvic acid, Fe(III)-fulvic acid complexes and colloidal iron-hydroxide were demonstrated not to affect uptake of dissolved As. To evaluate DGT as a method for accumulation and pre-concentration of total dissolved inorganic As in natural waters, DGT was applied to two well waters and a river water that was spiked with As. For each sample, the concentration obtained with use of DGT followed by measurement by hydride generation atomic absorption spectrometry with a Pd modifier (HG-AAS) was compared with the concentration of As measured directly by HG-AAS. The results confirmed that DGT is a reliable method for pre-concentration of total dissolved As.  相似文献   

11.
The agarose hydrogel has been increasingly used as a diffusive layer in diffusive gradients in thin films (DGT) measurements. However its diffusive characteristics have not been examined in detail. In this study, the performance of agarose gel was tested in DGT measurements of eight cations (Fe(II), Mn(II), Co(II), Ni(II), Cu(II), Zn(II), Pb(II), and Cd(II)) and eight anions (P(V), As(V), Cr(VI), Mo(VI), Sb(V), Se(VI), V(V), and W(VI)). It was found that the thickness of agarose, a key parameter in the calculation of DGT measured concentration, remained unchanged after hydration followed by storage under the following conditions: pH 2–11, ionic strength 0–1.0 M, temperature 4–40 °C, and with the storage time extending to 300 d. Enrichment of cations and repelling of anions were observed in the gel under the ionic strengths of < 2–3 mM and <1 mM (NaNO3), respectively, which was attributed to the electrostatic interactions of these ions with the fixed negatively charged groups (mainly pyruvate) in the gel. The diffusion coefficients of cations and anions through the agarose gel (plus a PVDF filter membrane) were on average 1.10 ± 0.04 times of the reported diffusion coefficients through the agarose cross-linked polyacrylamide (APA) hydrogel, typically used in DGT technique. The working pH ranges for the agarose gel-assembled DGTs were 4–10 and 5–9 for anions and cations, respectively. The use of agarose gel, either individually or along with different filter membranes, affected the overall diffusion rates of cations and anions. The measured DGT concentrations of cations and anions in filtered natural freshwater and seawater were mostly in line with those measured directly. The results showed that the agarose gel can be used as one of the standard diffusive layers in DGT measurements for a wide range of inorganic and organic analytes.  相似文献   

12.
The performance characteristics of an alternative binding agent, suspended particulate reagent-iminodiacetate (SPR-IDA), for use with DGT methodology were investigated. The parameters investigated during this study included gel hydration, blank levels, elution factor (fe), capacity, the effects of pH on the binding of trace metals by DGT. The novel application of this resin for use as a quantitative standard for laser ablation ICP-MS was also evaluated. To further constrain the results for the SPR-IDA binding agent, parallel experiments were performed using resin gel containing Chelex 100, which has been widely reported in the literature. Hydration results showed that the SPR-IDA resin gel reached a stable dimension and weight within ∼30 min and was dimensionally stable for ≤6 months. The measured DGT blanks for the SPR-IDA resin were 0.0023, 0.15, 0.21, 0.0033 and 0.011 ng disc−1 for Co, Ni, Cu, Cd and Pb, respectively. The elution factor differed for the two resin types with the Chelex 100 recoveries slightly lower than previous reports and the SPR-IDA resin showing on average ∼5-9% better recoveries than DGT containing Chelex 100. The measured capacity of DGT discs containing the SPR-IDA binding agent was 0.26 mg Cd, similar to the calculated value of 0.29 mg Cd, indicating the entire resin layer was available for metal uptake.Both resin types performed equally well when deployed in 1 mM NaNO3 solutions with DGT measurements of ∼100% of direct solution measurements for Co, Ni and Cd. However, DGT measurements of Cu and Pb systematically decreased with increasing solution pH down to ∼50% of solution values at pH 8.0, due to artifacts resulting from colloid formation during the addition of the metals. This was remedied by adding the metals as dilute salt standards and addition of Mg(NO3)2 to eliminate adsorption to the container walls. In the latter experiments, DGT measured concentrations of Co, Ni, Cu, Cd and Pb were in agreement with solution concentrations. Deployment of DGT in solutions with increasing concentrations of trace metals yielded linear results, suggesting that quantitative analysis using simplified laser ablation techniques should be possible using this newly characterized SPR-IDA resin gel.  相似文献   

13.
This study explores the use of pH stacking in conjunction with 5-aminofluorescein as a derivatization agent for the sensitive analysis of simple sugars such as glucose, lactose and maltotriose by capillary electrophoresis (CE). The derivatization agent was selected on the basis of its extremely high molar absorptivity, its compatibility with a 488nm light-emitting diode (LED) and the fact that it has two ionizable groups making it compatible with on-line stacking using a dynamic pH junction. The influence of both acetic and formic acids at concentrations of 0.19, 0.019 and 0.0019molL(-1) were investigated with regard to both derivatization efficiency and the ability to stack using a dynamic pH junction. Superior sensitivity and resolution was obtained in formic acid over acetic acid. Substantially lower peaks were obtained with 0.19molL(-1) formic acid when compared to 0.019 and 0.0019molL(-1) concentrations, which was confirmed by computer simulation studies to be due to the inadequate movement of the pH boundary for stacking. Further simulation studies combined with experimental data showed the separation with the best resolution and greatest sensitivity when the carbohydrates were derivatized with the 0.095molL(-1) formic acid. Utilisation of stacking via dynamic pH junction mode in conjunction with LED detection enabled efficiencies of 150,000 plates and detection limits in the order of 8.5x10(-8)molL(-1) for simple sugars such as glucose, lactose and maltotriose hydrate. The current system also demonstrates a 515 times improvement in sensitivity when compared to using a normal deuterium lamp, and 16 times improvement over other systems using LEDs.  相似文献   

14.
A systematic comparison of the diffusion coefficients of cations (Al, Cd, Co, Cu, Mn, Ni, Pb, Zn) and oxyanions (Al, As, Mo, Sb, V, W) in open (ODL) and restricted (RDL) diffusive layers used by the DGT technique was undertaken. Diffusion coefficients were measured using both the diffusion cell (Dcell) method at pH 4.00 and the DGT time-series (DDGT) method at pH 4.01 and 7.04 (pH 8.30 was used instead of 7.04 for Al) using the Chelex-Metsorb mixed binding layer. The performance of Chelex-Metsorb as a new DGT binding layer for Al uptake was also evaluated for the first time. Reasonable agreement was observed between Dcell and DDGT measurements for both ODL and RDL, except for V and W. The ratios of Dcell/DDGT for V of 0.44 and 0.39, and for W of 0.66 and 0.63 with ODL and RDL respectively, were much lower due to the formation of a high proportion of polyoxometalate species at the higher concentrations required with the Dcell measurements. This is the first time that D values have been reported for several oxyanions using RDL. Except for Al at pH 8.30 with ODL, all DDGT measurements were retarded relative to diffusion coefficients in water (DW) for both diffusive hydrogels. Diffusion in RDL was further retarded compared with ODL, for all elements (0.66–0.78) with both methods. However, the degree of retardation observed changed for cations and anions at each pH. At pH 7.04 cations had a slightly higher DDGT and oxyanions had a slightly lower DDGT than at pH 4.01 for both ODL and RDL. It is proposed that this is due to partial formation of acrylic acid functional groups (pKa ≈4.5), which would be fully deprotonated at pH 7.04 (negative) and mostly protonated at pH 4.01 (neutral). As Al changes from being cationic at pH 4.01 to anionic at pH 8.30 the results were more complex.  相似文献   

15.
A flow-injection chemiluminescence (CL) method has been proposed for sensitive determination of arsenate, germanate, phosphate and silicate, after separation by ion chromatography (IC). The post-column detection system involved formation of heteropoly acid in a H2SO4 medium before the CL reaction with luminol in an NaOH medium. For separation, heteropoly acid formation and the CL detection reaction, pH requirements were not compatible. When present as a heteropoly acid complex with molybdenum(VI), ger- manium(IV) and silicon(IV) caused CL emission from oxidation of luminol, and such a CL oxidation of luminol was observed analogously for arsenic(V) and phosphorus(V) but with the addition of metavanadate ion to the acid solution of molybdate. Good sensitivity for the three analytes arsenic(V), ger- manium(IV) and phosphorus(V) could be given by a single set of reagent conditions, chosen carefully. Another set was suitable for determining phosphorus(V) and silicon(IV). The minimum detectable concentrations of arsenic(V), germanium(IV), phosphorus(V) and silicon(IV) were 10, 50, 1 and 10 μg l−1, respectively. Linear calibrations for arsenic(V), germanium(IV), phosphorus(V) and silicon(IV) were established over the respective concentration ranges of 10–1000, 50–25000, 1–1000 and 50–1 μg l−1. The proposed IC–CL method was successfully applied to analyses of a seaweed reference material, rice wine and water samples.  相似文献   

16.
A synchronous fluorimetry for simultaneous determination of dissolved anthracene and pyrene in aqueous solution has been established. The linear ranges for determination of dissolved anthracene and pyrene were 1.00x10(-8) to 4.50x10(-7)molL(-1) and 5.00x10(-9) to 6.50x10(-7)molL(-1), and the limits of detection (LOD) for anthracene and pyrene were 2.23x10(-9) and 8.24x10(-10)molL(-1) with relative standard deviations (R.S.D.) of 2.90 and 2.34% (n=5), respectively. Satisfactory results were obtained when the established method was used to simultaneously determine anthracene and pyrene in spiked water samples.  相似文献   

17.
Mason S  Hamon R  Zhang H  Anderson J 《Talanta》2008,74(4):779-787
The effect of potential chemical constraints on the performance of two relatively new soil P testing methods, anion exchange membrane (AEM) and diffusive gradients in thin films (DGT), were evaluated. Exposures to ranges of anion (Cl(-), NO(3)(-), SO(4)(2-) and HCO(3)(-)) concentrations relevant to agricultural soils had minimal effect on P recoveries using DGT. It has also been shown previously that DGT P recoveries are unaffected by varying pH (3-9). In contrast, increasing NO(3)(-) and SO(4)(2-) concentrations in solution reduced the recovery of P using the resin method (anion exchange membrane, AEM) by 24% at 50mgL(-1) NO(3)(-) and by 47% at 12mgL(-1) SO(4)(2-) when the P concentration of the test solution was 2mgL(-1). Phosphorus sorption by the resin decreased with increasing Cl(-) concentrations until there was a 100% decrease at 300mgL(-1) Cl(-) when the P concentration of the test solution was 2mgL(-1) and a 92% reduction at 700mgL(-1) Cl(-) when the P concentration of the test solution was 0.2mgL(-1). There was also a small but significant effect of carbonate species on P sorption to the resin at carbonate concentrations that can occur in agricultural soils. Changing the pH of the solution had minimal effects on the resin P measurements in solutions above pH 4, but below pH 4, resin P measurements decreased dramatically. A poor coefficient of determination for the regression fit between DGT and resin measurements on eight agricultural soils suggested that these two methods are measuring different amounts of P for different soils. Resin P measurements increased significantly, but non-uniformly across soils, when the soil:water ratio was decreased but this did not result in an improved relationship with DGT P. There was a minimal effect on measured P using either Cl(-) or HCO(3)(-) as counter ions on the resin.  相似文献   

18.
The diffusive gradient in the thin films (DGT) technique was tested to measure dissolved mercury (Hg) both in laboratory aqueous solutions and in situ in river water. For this purpose, a commercial ready-to-use and specific-for-Hg DGT device was used. Each sampler consisted of a filter membrane-agarose gel as the diffusive layer and a Spheron-Thiol resin in polyacrylamide gel as the binding agent. Basic performance assays at the laboratory with this type of DGT unit confirmed the applicability of Fick's first law for DGT measurements. The diffusion coefficient of MeHg in the agarose diffusive gel was 8.50?×?10?6?cm2 s?1 at 25°C. Several field studies were also carried out in two different rivers of the Ebro River basin (NE Spain) affected by Hg wastes released by the chlor-alkali industry. Hg concentrations determined by DGT were generally much lower than the results obtained through direct measurements of the river water. In addition, the results of a time series experiment also performed in the field show that the amount of Hg accumulated in the resin does not increase at all with the exposure time. This may be explained by the underestimation of the truly dissolved Hg fraction due to the formation of a biofilm layer on the surface of the samplers, thus clogging the filter and preventing Hg species from diffusing through it. Consequently, it was demonstrated that the DGT technique presents important limitations for measuring Hg in polluted rivers characterised by a high biomass load (eutrophic), whereas its performance was demonstrated to be correct in oligotrophic waters.  相似文献   

19.
Wang J  He R 《Talanta》1996,43(3):391-396
A kinetic-dual standard additions method for simultaneous determination of interfering binary mixtures is proposed, and the principles discussed. The deviations of the absorbance from additivity in kinetic systems, caused by a synergistic effect between the two catalysts, are effectively compensated with the defined synergistic catalytic coefficient. The hydrogen peroxide-iodide kinetic reaction catalyzed by molybdate and tungstate was studied with a stopped flow injection technique, and the conditions for simultaneous determination of molybdate and tungstate were established. Contents of molybdenum and tungsten in different samples were determined with proposed procedure, the recoveries were 97.6-102.1% and 96.9-98.6%, and the relative standard deviations were 2.3-3.4% and 1.6-2.6% respectively.  相似文献   

20.
Electrospray time-of-flight mass spectrometry was used to study dilute (10(-3) M) solutions of tungstate, vanadate and perrhenate oxyanions under acidic and basic conditions. The electrospray mass spectra of tungstate and vanadate solutions indicate the presence of protonated monomeric oxyanions in basic solution (pH approximately 10) and protonated polymeric species in acidic solutions (pH approximately 4). Monomeric perrhenate was the only species detected in both acidic and basic perrhenate solutions. For all three systems, the core metalate species detected by electrospray were consistent with reported speciation in aqueous solutions. Copyright 2000 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏